Appendix A.pdf
PDF 186 KB Posted
- Attached to
- Construction Basic Ordering Agreement Federal contract opportunity
- Solicitation number
- FA448624R0002
About this file
This document is an appendix containing a list of reference standards that are applicable to the federal contract opportunity. The appendix provides the full name, acronym, and contact information for various industry associations, government agencies, and standards organizations whose standards may be referenced in the contract documents. It establishes the contractor's responsibility to comply with the specified standards and provide proof of compliance.
The related federal contract opportunity is for a Construction Basic Ordering Agreement to execute a broad range of maintenance and repair construction projects at Lajes Field Base and other off-base support sites in Terceira Island, Azores, Portugal. The work may involve demolition, site work, concrete, masonry, structural steel, electrical, HVAC, and other construction trades. The contractor will be required to have a Construction Certificate issued by the Instituto dos Mercados Publicos do Imobiliario e da Construcao (IMPIC) of Portugal.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA448624R00020005 SF 30.pdf | ||
| Solicitation Amendment - FA448624R00020005.pdf | ||
| Attachment 5 Questions and Answers.pdf | ||
| Solicitation Amendment FA448624R00020003 SF 30.pdf | ||
| Solicitation Amendment FA448624R00020002 SF 30.pdf | ||
| Solicitation Amendment FA448624R00020004 SF 30.pdf | ||
| Solicitation Amendment FA448624R00020001 SF 30.pdf | ||
| Attachment 2 Past Performance Information (PPI) Rev 1.pdf | ||
| Attachment 4 Questions and Answers.pdf | ||
| Solicitation - FA448624R0002.pdf | ||
| Appendix B.pdf | ||
| Attachment 1 Construction BOA Terms and Conditions.pdf | ||
| Attachment 3 Past Present Performance Questionnaire (PPQ).pdf | ||
| Appendix C.pdf | ||
| Attachment 2 Past Performance Information (PPI).pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 01 11 90 - REFERENCE STANDARDS
PART 01 - GENERAL
1.1 SECTION INCLUDES:
a. Applicability of Reference Standards.
b. Provision of Reference Standards at site.
c. Source and acronyms used for Reference Standards in Contract Documents.
1.2 APPLICABILITY OF REFERENCE STANDARDS:
a. For products or workmanship specified by association, trade or Federal Standards, comply with requirements of the standard except when more rigid requirements are specified.
b. The publications listed in the various specification sections form a part of the specification to the extent referenced. The publications are referred to in the text by basic designation only.
c. Use the latest standard except when a specific date is specified.
d. Disregard payment provisions contained in any portion of the referenced specifications and standards.
e. Throughout the Contract Documents, reference is made to codes and standards. These establish qualities and types of workmanship and materials, and establish methods for testing and reporting on the pertinent characteristics.
f. It is the Contractor's responsibility to provide materials and workmanship which meet or exceed the specifically named code or standard required by these Contract Documents.
g. It is also the Contractor's responsibility, when so required by the Contract Documents or by written request from the Contracting Officer, to deliver to the Contracting Officer all required proof that the materials or workmanship, or both, meet or exceed the requirements of the specifically named code or standard. Such proof shall be in the form requested in writing by the Contracting Officer and will generally be required to be copies of a certified report of tests conducted by a testing agency approved for the purpose by the Contracting Officer.
h. Specific names of codes or standards occur on the Drawings and in other sections of these
Specifications. Compliance with all laws; ordinances, and regulations of authorities having jurisdiction is an integral requirement of contract compliance. Deviation(s) shall only be by signed approval of the respective authorities having jurisdiction. All costs relative thereto shall be borne by the Contractor and included in the Contract price.
i. Familiarity with Pertinent Codes and Standards: In Procuring and installing all items of this work, it is the Contractor's responsibility to verify the detailed requirements of the specifically named codes and standards as well as all requirements mandated by law, ordinance and authority regulation and to verify that the items procured and installed in this work meet or exceed the specified requirements
j. Rejection of Non-Complying Items: The Contracting Officer reserves the right to reject items incorporated into the work, which fail to meet such minimum requirements.
k. The Contracting Officer further reserves the right, and without prejudice to other recourse the
Contracting Officer may take, to accept such items not complying with specified requirements subject to an adjustment in the Contract amount as approved by the Contracting Officer.
l. Applicable Standards: Standards referenced in the Specifications are usually referred to by the abbreviation of the organization's name and the designation of the document (e.g., ASTM A-36).
Documents in common use may be referred to by its own designation (e.g., the National Electrical Code is published by the National Fire Protection Association as NFPA-70, but is usually referred to as NEC and is part of a series of documents or standards referred to as the National Fire Code).
Unless otherwise indicated, references as to the latest issue of the publication available on the date stipulated for the receipt of bids. Not all standards identified in this list are necessarily required on any project.
1.3 PROVISION OF REFERENCE STANDARDS AT SITE: When required by individual specifications sections, obtain a copy of the standard. Maintain a copy at the jobsite during submittals, planning and progress of the specific work until completion.
1.4 SOURCE FOR REFERENCE STANDARDS:
AABC Associated Air Balance Council 1518 K St., NW Washington, DC 20005
AASHTO American Association of State Highway and Transportation Officials 444 N. Capitol St., NW, Suite 249 Washington, DC 20001
ACI American Concrete Institute P.O. Box 19150 Detroit, MI 48219
ACPA American Concrete Pipe Association 8300 Boone Blvd., #400 Vienna, VA 22182
ACPPAAsbestos Cement Pipe Producers Association 1745 Jefferson Davis Highway, Suite 406 Arlington, VA 22202
ADC Air Diffusion Council One I11. Ctr #200 111 E. Wacker Dr.
Chicago, IL 60601
AGA American Gas Association 1515 Wilson Blvd.
Arlington, VA 22209
AISC American Institute of Steel Construction One E. Wacker Dr., Suite 3100 Chicago, IL 60601-2001
AITC American Institute of Timber Construction 11818 SE Mill Plain Blvd., Suite 407 Vancouver, WA 98684
AMCA Air Movement and Control Association 30 West University Dr.
Arlington Heights, IL 60004
ANSI American National Standards Institute 11 West 42nd St.
New York, NY 10036
APA American Plywood Association S7011 South 19th Street P.O. Box 11700 Tacoma, WA 98411-0700
API American Petroleum Institute 1220 L St., NW Washington, DC 20005
AREA American Railway Engineering Association 50 F St., NW, Suite 7702 Washington, DC 20001
ARI Air-conditioning and Refrigeration Institute 1815 North Fort Myer Drive Arlington, Virginia 22209
ASHRAE American Society of Heating, Refrigerating, and Air-Conditioning Engineers 1791 Tullie Cir., NE Atlanta, GA 30329
ASME American Society of Mechanical Engineers 22 Law Dr., Box 2300 Fairfield, NJ 07007-2300
ASNT American Society for Non-destructive Testing 4153 Arlingate Plaza Columbus, OH 43228-0518
ASTM American Society for Testing and Materials 1916 Race Street Philadelphia, PA 19103
AWI Architectural Woodwork Institute P.O. Box 1550 Centreville, VA 22020
AWS American Welding Society P.O. Box 351040 Miami, FL 33135
AWWA American Water Works Association 6666 West Quincy Denver, CO 80235
BHMA Builders Hardware Manufacturers Association 60 East 42nd Street New York, New York 10017
CDA Copper Development Association, Inc 405 Lexington Avenue New York, New York 10017
CFR Code of Federal Regulations Order from:
Superintendent of Documents Government Printing Office Washington, DC 20402-9371
CGA Compressed Gas Association, Inc 500 5th Avenue New York, New York 10036
CISPI Cast Iron Soil Pipe Institute 2029 "K" Street Washington DC 20006
CRSI Concrete Reinforcing Steel Institute 933 No. Plum Grove Rd.
Schaumburg, IL 60173-4758
CS United States Department of Commerce Standard Order from:
National Technical Information Service 5285 Port Royal Rd.
Springfield, VA 22161
CSMA Chemical Specialties Manufacturing Association 50 East 41st Street New York, New York 1007
DIPRA Ductile Iron Pipe Research Association 245 Riverchase Parkway East, Suite O Birmingham, AL 35244
FAA Federal Aviation Administration Department of Transportation Order from:
Superintendent of Documents Government Printing Office Washington, DC 20402-9371
FM Factory Mutual System
1151 Boston-Providence Turnpike Norwood, Maryland 02062
HI Hydraulic Institute 1230 Keith Building Cleveland, Ohio 44115
IAPMO International Association of Plumbing and Mechanical Officials 5032 Alhambra Avenue Los Angles, California 90032
ICBO International Conference of Building Officials 5360 South Workman Mill Road Whitter, California 90601
IEEE Institute of Electrical and Electronics Engineers, Inc 345 East 47th Street New York, New York 10017
IES Illuminating Engineering Society 346 East 47th Street New York, New York 10017
MSS Manufacturers Standardization Society of the Valve and Fittings Industry 1815 North Myer Drive Arlington, Virginia 22209
NBS National Bureau of Standards Office of Weights and Measures Room A209, Metrology Building Washington DC 20234
NEBB National Environmental Balancing Bureau 1611 North Kent Street Arlington, Virginia 22209
NEC (See NFPA)
NEMA National Electrical Manufacturers Association 2101 "L" Street N. S.
Washington DC 20037
N FLUID National Fluid Power Association PA 3333 North Mayfair Road, Suite 311 Milwaukee, Wisconsin 53222
NFPA National Fire Protection Association 470 Atlantic Avenue Boston, Mass. 02110
NSF National Sanitation Foundation NSF Building 3475 Plymouth Road Ann Arbor, Michigan 48106
PS See (NBS)
RFCI Resilient Floor Covering Institute 966 Hungerford Dr.,Suite12-b Rockville, MD 20850 (301)340-8580
SMACNA Sheet Metal and Air Conditioning Contractors National Association 8224 Old Courthouse Road Tysons Corner Vienna, Virginia 22180
SDE Steel Deck Institute Box 3812 St. Louis, Missouri 63122
SSPC Steel Structures Painting Council 4400 Fifth Avenue Pittsburgh PA 15213
TCA Tile Council of America P.0. box 326 Princeton, New Jersey 08540
UBC See (ICBO)
UL Underwriter's Laboratories, Inc 333 Pfingsten Road Northbrook, Illinois 60662
UMC Uniform Mechanical Code - See IAPMO
UPC Uniform Plumbing Code - See IAPMO
USBCB United States Architectural and Transportation Barriers Compliance Board Washington DC 20407
Mil. Naval Supply Depot
Spec. 5801 Tabor Avenue Philadelphia PA 19120
CEN European Committee for Standardization Avenue Marnix 17 B-1000 Brussels
CENELEC European Committee for Electrotechnical Standardization Avenue Marnix 17 B-1000 Brussels
For documents offered at no cost, order from: Dept. of Transportation
ATTN: M443.2
400 Seventh St., SW Washington, DC 20590
MSS Manufacturers’ Standardization Society of the Valve and Fittings Industry 127 Park St., NE
Vienna, VA 22180
NACE National Association of Corrosion Engineers P.O. Box 218340 Houston, TX 77218-8340
NBS National Bureau of Standards Department of Commerce Gaithersburg, MD 20234
NEMA National Electrical Manufacturers’ Association 2101 L St., NW Washington, DC 20037-1526
NFPA National Fire Protection Association P.O. Box 9146 Quincy, MA 02269
NRCA National Roofing Contractors Association 10255 West Higgins Road, Suite 600 Rosemont, Illinois 60018-5607
NSF NSF International 3475 Plymouth Rd.
P.O. Box 130140 Ann Arbor, MI 48113-0140
NWMA National Woodwork Manufacturers’ Association (Now NWWDA)
NWWDA National Wood Window and Door Association 205 West Touhy Ave Park Ridge, IL 60068
OSHA Occupational Safety and Health Administration (U.S. Department of Labor) Order from:
Superintendent of Documents Government Printing Office Washington, DC 20402-9371
SMACNA Sheet Metal and Air-Conditioning Contractors’ National Association P.O. Box 221230 Chantilly, VA 22022
SSPC Steel Structures Painting Council 4400 Fifth Ave.
Pittsburgh, PA 15213-2683 UBC
Uniform Building Code
International Conference of Building Officials 5360 South Workman Mill Rd.
Whittier, CA 90601
UBPPAUni-Bell PVC Pipe Association 2655 Villa Creek Dr., Suite 155 Dallas, TX 75234
UL Underwriters' Laboratories, Inc.
333 Pfingston Rd.
Northbrook, IL 60062
UPC Uniform Plumbing Code International Conference of Building Officials 5360 South Workman Mill Rd.
Whittier, CA 90601
WCLIBWest Coast Lumber Inspection Bureau P.O. Box 23145 Portland, OR 97223
WWPAWestern Wood Products Association Yeon Bldg.
522 SW 5th Ave. Portland, OR 97204-2122
PART 2 PRODUCTS: Not Used.
PART 3 EXECUTION: Not Used.
END OF SECTION