Appendix A and B is a detailed specification document for Alternate Transportable Temporary Housing Units (ATTHUs) for Maui County, Hawaii, in response to the August 2023 wildfire disaster. The document provides comprehensive requirements for furniture, fixtures, appliances, equipment, and modular home specifications across 1-3 bedroom unit configurations.
Appendix A outlines exact furniture requirements, including specific details for items like couches, beds, dining tables, appliances, and kitchen equipment. Each item has precise specifications for material, dimensions, durability, and safety standards. Appendix B details modular home engineering and certification requirements, addressing design, foundation, transportation, and installation specifications. The homes must comply with Maui County Building Codes, including regulations for residential zoning, environmental compliance, and structural integrity. The modular units are designed to be flexible, with options for temporary or permanent foundations, and must meet stringent safety and building standards for wind loads, material composition, and utility connections.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI_HI ATTHU Modular Units_20250313.pdf | ||
| RFI Response Sheet ATTHU.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix A: Furniture, Fixtures, Appliances, and Equipment (FFAE) Requirements
General: Contractor to specify and provide an adjusted FFAE list if the listed items below do not fit in the floor plan configurations submitted for approval to Maui County; one-bedroom one-bath (1/1), two-bedroom one-bath (2/1), and three-bedroom two-bath (3/2).
Furniture:
Item Description 1 Bed / 1
Bath 2 Bed / 1
Bath 3 Bed / 2
Bath
Three Cushion Couch 1 1 1
Armchair 0 1 1
Coffee Table 1 1 1
End Table 1 1 1
Wood Dining Table (see applicable description per unit type) 1 1 1
Wood Dining Chairs (see applicable description per unit type) 4 4 6
Full size bed frame 1 2 2
Full size mattress and box spring set 1 2 2
XL-Twin Free standing bunk bed frame, not built into unit 0 0 2
Medium Hybrid XL Twin Mattress and Box Spring 0 0 2
5 Drawer Dresser(s) 1 2 3
Nightstand(s) 1 2 3
Three Cushion Couch:
• Neutral color
• Three cushions
• Support standard weight limit of approximately 250-300 pounds per seat cushion
• Has arm rests
• Non-sleeper sofa
• Not a sectional sofa
• Does not have a footrest
• Quality furniture new condition
• Fabric or material used shall sustain rough and tumble usage
• Free of sharp, abrasive surfaces and edges
• Durable for a minimum of eighteen (18) months of use
• No assembly required
• Free of defects. Meets federal flammability standards
Armchair:
• Neutral color
• Constructed of non-permeable materials without fabric covering
• Has arm rests
• Does not have a footrest
• Non-rocking chair
• Does not recline
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for a minimum of eighteen (18) months of use
• No assembly required
• Free of defects
• Meets federal flammability standards.
Coffee Table:
• Constructed from wood
• Rectangle shape
• Four legs
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for a minimum of eighteen (18) months of use
• No assembly required
• Meets federal flammability standards
End Table:
• Square or rectangle shape
• Constructed from wood
• Neutral color
• Four legs
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for a minimum of eighteen (18) months of use
• No assembly required
Wood Dining Table:
• Table and chairs for 3 bedroom o Constructed from solid hardwood o Table is rectangle shape o Table accommodates six chairs o Table is not extendable
• Table and chairs for 1-2 bedroom o Constructed from solid hardwood o Table is rectangle shape o Table accommodates four chairs o Table is not extendable
Wood Dining Chairs:
• All chairs are the same size and match
• Chairs have four legs
• Chairs have no upholstery
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for eighteen (18) months of use
• No assembly required
Full size bed frame:
• Constructed from rust-resistant metal
• No headboard is required
• Accommodates one (1) full size mattress (54” W x 75” L) and box spring (54” W x 75” L)
• No storage drawers or shelves
• Not a wall-bed
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for eighteen (18) months of use
Full size mattress and box spring set:
• Innerspring mattress
• Comfort Performance: Provide comfortable and supportive sleep surface for various body types and sleeping positions
• Durability: Ensure long-term durability, resistance to sagging, and structural integrity over extended use
• Motion Isolation: Minimize motion transfer for undisturbed sleep
• Breathability: Regulate temperature with adequate airflow and heat dissipation
• Edge Support: Offer strong and stable edge support for maximum usable surface area
• Compatibility: Ensure seamless integration between mattress and box spring components
• Safety and Health: Meet industry safety standards and certifications for user safety
• Non-latex
• Medium firmness
• Polyester, cotton, or blend ticking and wadding
• New condition
• Durable for eighteen (18) months of use Free of defects
XL-Twin Free standing bunk bed frame, not built into unit:
• Constructed from solid, finished wood and/or rust-resistant metal
• Freestanding
• Accommodates two (2) XL twin size mattresses (each 39” W x 80” L) without box springs.
• Has attached ladder
• Upper bed bunk has a guardrail without any gaps between the rail and the upper bed bunk frame.
• No storage drawers or shelves
• Free of sharp, abrasive surfaces and edges
• New condition
• Durable for eighteen (18) months of use
XL-Twin Mattress and Box Spring Innerspring Mattress:
• Comfort Performance: Provide comfortable and supportive sleep surface for various body types and sleeping positions
• Durability: Ensure long-term durability, resistance to sagging, and structural integrity over extended use
• Motion Isolation: Minimize motion transfer for undisturbed sleep
• Breathability: Regulate temperature with adequate airflow and heat dissipation
• Edge Support: Offer strong and stable edge support for maximum usable surface area
• Compatibility: Ensure seamless integration between mattress and box spring components
• Safety and Health: Meet industry safety standards and certifications for user safety
• Non-latex
• Medium firmness
• Polyester, cotton, or blend ticking and wadding
• New condition
• Durable for eighteen (18) months of use
5 Drawer Dresser(s):
• Should be constructed from durable materials, such as solid wood or high-quality engineered wood.
• The drawers should glide smoothly on metal tracks and include safety stops to prevent accidental removal.
• Sturdy frame and reinforced drawer bottoms to handle heavier items without sagging.
• The dresser should be stable with an anti-tip feature for safety.
• Easy-to-clean surfaces.
• Rectangle shape
• Neutral color
• Hardware included.
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for eighteen (18) months of use
• No assembly required.
Nightstand(s)
• Constructed from wood.
• Rectangle Shape
• Neutral color
• Two-drawers
• Hardware included.
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for up to eighteen (18) months during occupancy
• No assembly required.
Fixtures:
Item Description 1 Bed / 1 Bath 2 Bed / 1 Bath 3 Bed / 2 Bath
Vinyl Mini Blinds 1” Cordless, White, or Automatic Blinds. All windows shall have mini blinds installed. These mini blinds shall be designed to meet required industry safety standards and
Consumer Product Safety Commission recommendations.
Roughly 6-12, TBD for actual
ATTHU specs
Roughly 9-12, TBD for actual
ATTHU specs
Roughly 12, TBD for actual ATTHU specs
Vertical Door Blinds & Shades for Sliding Doors TBD for actual
ATTHU specs
TBD for actual
ATTHU specs
TBD for actual
ATTHU specs
Bathroom Medicine Cabinet: Roughly 20" Wide x 36" Tall 1 1 1-2
Towel Bar: 24-Inch in Polished Chrome 1 1 2
Toilet Paper Holder: (Material Only) 1 1 2
Shower Curtain: Roughly 66"L x 74"H for 60’’ wide showers.
Roughly 42” L X 74” H for 36’’ wide showers.
1 1 2
Shower Curtain Liner: Roughly 66"L x 74"H for 60’’ wide showers. Roughly 42” L X 74” H for 36’’ wide showers.
1 1 2
Shower Curtain Rod: roughly 31- 80 Inch,1 Inch diameter
Adjustable matte silver spring tension.
Stainless steel telescoping rod, easy install, no rust
1 1 2
Shower Curtain Rings:12 Pack, plastic shower curtain hooks O-shaped rings hook glide easily on bathroom shower rod (black)
1 1 2
Shower Stall: Multi-piece barrier free roughly 36’’ x 36’’ x 80’’.
1/8’’ shower with beveled threshold and a 5/8’’ curb height
1 1 2
Shower Stall: Multi-piece barrier free roughly 60’’ x 30’’ x 80’’.
1/4’’ shower with beveled threshold and a 1/2 curb height
1 1 2
T-shaped rubber water stopper 1 1 2
Accessory package for 60" wide barrier free shower with valve package
1 1 2
Accessory package for 36" wide barrier free shower with valve package
1 1 2
Padded Bench Shower Seat with Legs: Roughly 19" H x 24" W x 15" D
1 1 2
Lift Station: 1/2 HP submersible pre-plumbed sewage ejector basin system
TBD for actual
ATTHU specs
TBD for actual
ATTHU specs
TBD for actual
ATTHU specs
Grinder Pump: 1/2 HP residential sewage grinder system with 18 Inch basin TBD for actual
ATTHU specs TBD for actual
ATTHU specs
TBD for actual
ATTHU specs
Mini Blinds
• Vinyl slats
• Horizontal orientation slats
• Washable slats
• Smooth surface slats
• Stain resistant slats
• Fade resistant slats
• Bottom-up opening type
• Light filtering
• Mountable
• Outside mount type
• With installation brackets and mounting hardware included
• White in color
• Matching white vinyl headrail
• Cordless
• Includes wand tilt
• Made with non-lead formula
• No assembly required
• New condition
• Free of defects
• All materials meet federal flammability standard.
• ANSI certified
Mini-blinds dimensions: TBD based on window sizes from manufacture.
• Size: Ensure that the mini blinds fit the windows' accurate measurements.
• Mounting: Install the mini blinds based on manufacture specification for each window.
Door Blinds and Shades for Sliding Doors
• Roughly 78” W X 84” H
Medicine cabinet with mirrored door
• Surface mount or recessed
• No assembly required.
• Rectangle shape
• Contains two (2) interior shelves.
• Reversible door able to be installed to open to either the left or the right.
• Cabinet hardware included.
• Mounting hardware included
• No light fixture
• Mirror on exterior of door
• Neutral colored cabinet and door frame
• Cabinet and shelves constructed of wood or aluminum.
• Free of sharp, abrasive surfaces and edges
• Durable for a minimum of eighteen (18) months of use
• New condition
• All materials meet federal flammability standards.
Medicine cabinet dimensions:
• Roughly 20” W to 24” W
• Roughly 24” H to 36” H
Towel bar
• Metal with chrome finish
• Wall-mountable
• Includes mounting hardware
• Single towel bar
• Rust resistant
• Free of sharp, abrasive surfaces and edges
• Durable for a minimum of eighteen (18) months of use
• New condition
Towel bar dimensions:
• Roughly 24” L
• Roughly 2” H to 3” H (Bracket)
• Roughly 3” D to 5” D (Depth)
Toilet paper holder
• Metal with chrome finish
• Wall-mountable
• Includes mounting hardware.
• Rust resistant
• Single toilet paper roll capacity
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for a minimum of eighteen (18) months of use
Within the dimension range:
• Roughly 4” W to 8” W
• Roughly 2” H x 4” H (Bracket)
• Roughly 2” D x 4” D (Depth)
• Metal with chrome finish
• Single rod
• Straight rod
• Rust resistant
• Free of defects
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for eighteen (18) months of use
Bathroom shower curtain
• Roughly 71” L X 79” H
• Roughly 66” L X 74” H
• Roughly 42” L X 74” H
Shower curtain rods
• Roughly 31” L to 80” L
• Roughly 31” L to 64” L
• Roughly 1” D
Shower curtain rings
• 12 pack plastic
Multi-Piece Barrier Free Shower
• Roughly 36 X 36 X 80 1/8 and 5/8 Curb Height
• Roughly 60 X 30 X 80 ¼ and 1/2 Curb Height
• Beveled Threshold
T-shaped rubber water stopper (configuration may vary depending on shower design)
• Base – 1 and ¼ inches
• Height - 1 and 3/8 inches
• Endcap set configuration #1 - Radius 3/8 inches
• Endcap set configuration #2 - Radius 2 and ¼ inches
• Length: 60 inches
Accessory package for 60" Wide barrier free shower with valve package
Accessory package for 36" Wide barrier free shower with valve package
Stainless Steel Bath Safety Grab Bar
• 12, 18, 24, and 48 inches.
• 500 lbs. loading capacity
Padded Bench Shower Seat with Legs
• Roughly 19" H x 24" W x 15" D
Lift Station ½ HP Submersible Pre-plumbed Sewage Ejector Basin System (configuration may vary depending on ATTHU design)
Grinder Pump (configuration may vary depending on ATTHU design)
• Roughly 18 in x 30 in. 1/2 HP Grinder Pump
Appliances
Countertop Microwave Oven 1 1 1
Electric Range 1 1 1
Frost-Free Refrigerator Top-Freezer 1 1 1
Under Cabinet Range Hood 1 1 1
Countertop Microwave
• Contains turntable
• Push to open door
• Right to left swing door
• Touch-control panel
• LED digital display
• Scratch-resistant glass door
• Door with child safety lock
• Wattage: 950W to 1100W
• Meets UL safety listing
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for eighteen (18) months of use
• No assembly required
• Free of defects
• 1.2 cu. ft. minimum size
• Less than 12” H
Electric Range
• Self-cleaning
• Roughly 30 Inch
• 4 burners
• Thermostatically controlled and lighted conventional oven with indicator lights that show that the burners are operating or are hot.
• Range/Oven controls shall be located so that the user does not have to reach across burners to use the range/oven.
Refrigerator
• Roughly 18 cu. ft. total capacity
• Freezer on top
Under Cabinet Range Hood
• 30-Inch
• Hood with 2 Speed Exhaust Fan
• Ducted/Ductless Convertible Kitchen Hood
• Stainless steel vent hood with LED light
• Under Cabinet hood with 2 Speed Exhaust Fan
Equipment
Lighting Emitting Diode (LED) Bulbs Installed in all light fixtures
Installed in all light fixtures
Installed in all light fixtures
Dehumidifier TBD TBD TBD
210 Fire Extinguisher (2A:10-B:C) 1 1 1
R400 Weather Radio Deluxe 1 1 1
SBNDL Bundle Kit STR180 Strobe Light and
SHKR100 Pillow Shaker with Y Cable
2 4 6
Dual Connector for Weather Alert System compatible with R400 Weather Radio
2 4 6
Pillow Shaker for R400 Weather Radio 1 1 1
Strobe Light Compatible with R400 Weather
Radio
1 1 1
AA batteries 4 8 12
LED Light Bulbs
• Medium screw base
• Soft white light color
• Spiral bulb shape
• 900 lumens light output
• Mercury free
• New condition
• Free of defects
• Equivalent to sixty (60) watt bulb each
• Installed.
Dehumidifier
• Capacity up to 1200sf
Fire Extinguisher
• 2A:10-B:C rated
• Rechargeable
• Multi- Purpose for Home & Office
• 4 lbs.
• Mounting Bracket Included
• Red
• Dry powder type
• Mounting bracket included
• Mounting hardware included
• Made of rust-resistant metal
• Includes pressure gauge.
• Free of sharp, abrasive surfaces and edges
• Durable for eighteen (18) months
• New condition
• Discharge range: 10’ to 15’
• Operating pressure: 100 psi
• Meets UL safety listing.
R400 Weather Radio Deluxe
• Tunable to NOAA’s 24/7 National Weather Service broadcast
• S.A.M.E. Digital Weather/Hazard alert feature that provides constant monitoring of local National Weather Service broadcast.
• Approved by Federal Communications Commission (FCC) and the National Oceanic and Atmospheric
Administration (NOAA)
• Works with electrical power and battery backup.
• Compatible with an external, connectable strobe light
• Uses AA batteries.
• New condition
• Free of sharp, abrasive surfaces and edges
• Durable for eighteen (18) months of use
• No assembly required.
• Free of defects
• Home Use with Battery Backup
• Local County Programming
• Over 80 Emergency Voice Flashing Alerts
• Alarm Clock AM/FM Radio
SBNDL Bundle Kit (Strobe Light and Pillow Shaker Compatible with R400 Weather Radio)
• Includes both SHKR100 Pillow Shaker and STR180 Strobe Light Strobe Light
• New condition
SHKR100 Pillow Shaker
• Notification Compatible with R400 Weather Radio
• Vibrates/shakes during emergency weather alerts
• New condition
STR180 Strobe Light Strobe Light
• Notification Compatible with R400 Weather Radio
• Bright LED lights
• Flashes during emergency weather alerts
• New condition
Dual Connector
• Dual Connector for Weather Alert System compatible with WR400 Weather Radio
AA battery
• New condition
• Disposable
• Not rechargeable
• 1.5 Volts
• Mercury free
Appendix B: Specifications for Modular Temporary Housing The list of building codes, laws and regulations pertaining to modular homes in Maui contained in “Building Codes Applicable to Maui Appendix” is not certified by FEMA to be all inclusive. The contractor is responsible for identifying and complying with all applicable codes, laws and regulations.
Building Plans Review Section https://mauicounty.gov/DocumentCenter/View/143729
1. Overview: The Building Plans Review Section reviews building permit applications for compliance with the adopted building code and energy conservation code.
2. Modular Defined: for the purposes of this PWS, Modular is defined as having fixed frame/walls. This differentiates from other types of designs on the market whereby their structure is considered expandable, foldable, and/or slidable.
3. Codes Enforced: On October 28, 2023, the County of Maui will start enforcement of the following building-related codes:
A. Building Code Administrative and Supplemental Provisions Maui County Code, Chapter 16.25 –
County Ordinance 5507 *NEW CHAPTER*
B. 2018 International Building Code (IBC) county amendments
Maui County Code, Chapter 16.26C Building Code
County Ordinance 5508
C. 2018 International Residential Code (IRC) state amendments
Maui County Code, Chapter 16.08B Residential Code
(county amendments TBD)
D. 2018 International Existing Building Code (IEBC) state amendments
Maui County Code, Chapter 16.10 Existing Building Code
(county amendments TBD)
*NEW CODE/CHAPTER*
E. 2018 International Energy Conservation Code (IECC) state amendments
2018 International Energy Conservation Code (IECC) county amendments
MCC Chapter 16.16C Energy Code
County Ordinance 5455
Sample Energy Code Certification Block: Commercial - Residential
F. Building permits applications submitted on and after October 28, 2023 must comply to the codes listed above. Building permit applications submitted prior to October 28, 2023 will be reviewed under the codes enforced at the time of submission.
G. The ATTHU vendor should not construct units until design registration approval by Maui County has been provided.
H. Solar Water Heater System Required for New Dwellings
Hawaii Revised Statutes, Section 196-6.5
Solar Water Heater Variance
I. Agricultural Buildings and Structures Exemption
Hawaii Revised Statutes, Section 46-88
J. Maui County Code https://mauicounty.gov/DocumentCenter/View/143729 https://www.mauicounty.gov/DocumentCenter/View/143722 https://www.mauicounty.gov/DocumentCenter/View/143723 https://www.mauicounty.gov/DocumentCenter/View/143724 https://www.mauicounty.gov/DocumentCenter/View/143725 https://www.mauicounty.gov/DocumentCenter/View/143726 https://www.mauicounty.gov/DocumentCenter/View/143727 https://mauicounty.gov/DocumentCenter/View/143729 https://mauicounty.gov/DocumentCenter/View/143730 https://www.capitol.hawaii.gov/hrscurrent/Vol03_Ch0121-0200D/HRS0196/HRS_0196-0006_0005.htm http://energy.hawaii.gov/resources/solar-water-heater-variance https://www.capitol.hawaii.gov/hrscurrent/Vol02_Ch0046-0115/HRS0046/HRS_0046-0088.htm https://library.municode.com/hi/county_of_maui/codes/code_of_ordinances?nodeId=COCOMAHA
4. Supported Applications: Design Registration
DSA Design Registration
Overview
Design Registration is solely intended for architects and structural engineers to register dwelling construction plans for multiple building permit applications, typically used for subdivisions.
Review is limited to building & energy code compliance.
How to Apply You must have a MAPPS Customer Self Service account in order to apply online. Complete the information in all the steps in MAPPS CSS then upload the required documents and plans related to your application. To avoid delays in processing your application, please follow these guidelines:
• Design Registration Guidelines
• PHASE 1 - REGISTER MODEL PLANS
Contact Building Plans Review Section to submit the Pre-Consultation form and discuss project summary. Submit design registration application, one application per each model. After reviewed and approved,
• PHASE 2 - DESIGN REGISTRATION SUB-RECORD BUILDING PERMIT
Building permit applications are to be applied as a Sub-Record of the Design Registration. Do not apply under the Building Permit - New/Addition/Alteration.
Go online to MAPPS CSS to apply for:
• Design Registration
Forms
• Design Registration Pre-Consultation Form
• Authorization - Design Professional
Fees The design registration fee is $500.00 for each model. Applicant will be notified when payment is due.
Resources
• MAPPS CSS Helps
• Design standards for submitting plans
• Hawaii State Residential Code 2012 IRC (source: Maui County website; ref. latest code for accuracy)
• Hawaii State Building Code 2012 IBC (source: Maui County website; ref. latest code for accuracy)
5. Additional Information:
A. International Code Council: Learn more about the International Code Council by visiting their website.
Code books and other publications can be purchased at the ICC Store.
https://hi-mauicountymapps.civicplus.com/295/DSA-Design-Registration https://hi-mauicountymapps.civicplus.com/9/How-Do-I https://mapps.co.maui.hi.us/EnerGov_Prod/SelfService%23/home https://mapps.mauicounty.gov/DocumentCenter/View/284 https://mapps.co.maui.hi.us/EnerGov_Prod/SelfService%23/permit/apply/1207/0/0 https://mapps.mauicounty.gov/DocumentCenter/View/216 https://mapps.mauicounty.gov/DocumentCenter/View/215 https://hi-mauicountymapps.civicplus.com/9/How-Do-I https://hi-mauicountymapps.civicplus.com/301/Submission-Standards-for-MAPPS-CSS https://www.mauicounty.gov/1308/Building-Plans-Review-Section https://www.mauicounty.gov/1308/Building-Plans-Review-Section http://www.iccsafe.org/ http://shop.iccsafe.org/
B. State Building Code Council: Act 82, SLH 2007 (the Act) created the State Building Code Council (the
Council) which is administratively attached to the Department of Accounting and General Service. The purpose of the Council is to establish a state building code which would eliminate the fragmented building requirements which currently exist between counties. The state building code would include the latest fire code as adopted by the State Fire Council, the latest edition of the International Building Code, the latest edition of the Uniform Plumbing Code, and Hawaii design standards to implement Act 5, Special Session
Laws, 2005 as applicable to emergency shelters and essential government facilities.
C. Disability and Communication Access Board (DCAB): The Building Plans Review Section requires a
"Document Review" compliance letter from DCAB for all State of Hawaii and County of Maui projects prior to the issuance of a building permit.
6. Modular Homes in Compliance with Maui Building Code:
Modular homes offer a contemporary approach to addressing housing needs within Maui County's residential lots (R-1, R-2, R-3 & R-0), combining efficiency, quality, and strict adherence to the Maui Building Code's rigorous standards.
7. Engineering and Certification Requirements:
To meet the Maui Building Code, the installation and construction of modular homes demand meticulous engineering precision. Accredited Architects or Engineers oversee every phase, ensuring compliance or exceeding applicable codes. This rigorous process guarantees structural safety and resilience against Maui's unique environmental challenges.
A. Structural Integrity: From foundation to load-bearing framework, every aspect undergoes scrutiny and certification by professionals to ensure structural reliability and safety.
B. Mechanical, Plumbing, and Electrical Systems: Factory-installed systems adhere to specific labels and certifications, ensuring safety and reliability integral to the home's functionality.
C. Code Section Highlights: Key code sections (e.g., 16.08A.R101.2, 19.62.060, 109-4, SECTION R301.1.2.1, 1704.15) emphasize adherence to safety standards and structural integrity. These codes play a pivotal role in ensuring compliance with the Maui Building Code's stringent requirements.
1) 16.08A.R101.2: Scope of application for One- and Two-family Dwellings under the International
Residential Code.
1. 19.62.060: Standards for development necessitate certification by an architect or engineer for flood hazard reduction in new construction.
2. 109-4: Installation or relocation of factory-built dwellings requires an electrical permit and compliance with federal construction and safety standards.
3. SECTION R301.1.2.1: Specifics on ensuring a complete load path and uplift ties for structural integrity.
4. 1704.15: Mandates termite protection measures for new wooden frames in residential buildings.
8. Flood-Prone Area Regulations: The Maui Building Code intricately outlines regulations concerning flood-prone areas, necessitating robust design, anchoring, and construction practices. Modular homes are constructed to withstand potential flooding by utilizing flood-resistant materials and specific construction techniques.
9. Residential Zoning and Area Regulations: Adherence to zoning setbacks and area requirements is crucial in integrating modular homes seamlessly into Maui's residential zones (R-1, R-2, R-3). A balance between innovative housing solutions and strict spatial regulations ensures compliance without compromising structural integrity or aesthetics.
10. Environmental Compliance: Ensure compliance with environmental regulations in Maui County and FEMA's environmental standards, particularly regarding waste management, erosion control, and protection of natural resources during the manufacturing, transportation, and installation processes.
11. 1 – 3 Bedroom Modular Home Specifications with Optional Permanent Foundation:
A. General Modular Home Specifications:
http://ags.hawaii.gov/bcc/ http://health.hawaii.gov/dcab/
1) Design: These homes are specifically designed to be 1-3 bedroom modular units, ensuring easy transport, installation, and providing flexibility for either temporary or permanent placement. The modular nature of these units simplifies transportation and installation processes.
2) Size: The one-bedroom no larger the 14x35 keeping unit under 448 SF, while the 14x55 two-bedroom units under 770 SF and three-bedroom unit 14x70 being limited under 980 SF. Each unit is intricately designed as a single piece, streamlining transportation, and facilitating swift installation.
3) Rooms: Each home will include a living area, kitchen, bathroom(s), and 1-3 bedrooms. The kitchen should be equipped with standard appliances (refrigerator, stove, etc.), and the bathroom should contain a toilet, sink, and shower or bathtub. Additional rooms such as a laundry room or office could be included based on the size of the home.
4) Roof: The homes will feature a roof designed to withstand the wind loads common in Maui County. The roof will be constructed with a designed standard for the specific wind and weight loads and covered with a roofing material suitable for the local climate, such as asphalt shingles or metal roofing.
5) Materials: The homes will be constructed primarily of wood and steel, with insulation. The exterior walls should be made of 2x4 or 2x6 framing, covered with plywood or OSB sheathing, and a weather-resistant barrier. The interior walls should be covered with drywall. The flooring should be made of a sturdy material such as plywood or concrete, with a suitable floor covering such as carpet, vinyl, or tile.
The above requirements can be modified or changed by the contractor. If the contractor proposes any changes the contractor must explain the changes in clear enough detail for FEMA to evaluate the applicability of the change. In addition, the contractor shall provide FEMA with a justification for the proposed change and a rational explaining, in detail, how the change is beneficial to the government. This language is appliable to this Appendix of the PWS and to Sections 8 and 12 of the PWS, the Unit Specifications.
6) Utilities: These homes come equipped and prepped for connection to local utility services, encompassing electricity, water, and sewer.
B. Foundation Specifications:
1) Type: These homes are versatile and adaptable, designed to be set on either a temporary foundation (such as pier or pile foundation) or a permanent foundation (such as a slab or crawl space foundation), based on the homeowner's preferences and needs.
2) Materials: The temporary foundation comprises steel or concrete piers driven into the ground, supported by steel beams to uphold the home. In contrast, a permanent foundation is constructed using poured concrete or concrete blocks for increased durability and longevity.
3) Design: The temporary foundation for the modular home in Maui County, Hawaii, will be engineered in according to local building codes. It will be designed to support the specific requirements of the manufactured unit, ensuring proper load distribution and structural stability.
High-quality materials approved by local authorities will be used, and rigorous quality control measures should be implemented during construction. The foundation will be designed to withstand environmental factors such as seismic activity and wind loads, providing a durable and safe support system for the modular home.
C. Transportation and Installation:
1) Transportation: These modular homes are manufactured in an indoor factory and then transported to the site as a single, cohesive piece, simplifying logistics and minimizing assembly requirements upon arrival.
2) Installation: Skilled professionals lift the home onto the chosen foundation, ensuring it is securely placed and completing any necessary finishing work.
3) Utilities: Upon installation, utilities such as electricity, water, and sanitary systems are connected to ensure the home is fully functional.
D. Future Relocation (for homes with Temporary Foundation):
1) Dismantling: When required to relocate, the home is carefully lifted off the temporary foundation and prepared for transportation.
2) Transportation: The home is transported to the new site using a method similar to its initial installation, maintaining the integrity of the structure during transit.
3) Reinstallation: At the new site, the home is placed on a new temporary foundation following the same rigorous process as its original installation.
E. Conclusion: Modular homes, engineered and installed in strict accordance with the Maui Building Code, offer efficient housing solutions while upholding structural integrity, safety, and compliance with Maui County's stringent building standards.
Note: Consultation with professionals is advised for specific home designs and compliance assurance.