Appendix A - 2020-0088 EAB LSA Roberts DFAC - Drawings.pdf
PDF 9 MB Posted
- Solicitation number
- W5J9JE22R0002
About this file
This solicitation notice is for a design-build construction contract to construct a new dining facility at Erbil Air Base in Iraq. The project includes design and construction of a pre-engineered metal building kitchen and dining facility to seat 200 personnel, along with generators, fuel tanks, water tanks, wastewater infrastructure, site utilities, paving and furnishings. The magnitude of construction is estimated between $1-5 million. Offerors must be registered in SAM and JCCS and obtain applicable Kurdistan Region licenses and clearances. This is a two-phase design-build solicitation utilizing full and open competition. Phase I proposals are due on January 31st, 2022 with Phase II amendments issued thereafter and proposals due February 18th and award by April 15th, 2022. The contract will be awarded based on best value determination considering evaluation factors conveyed in the RFP. Defense Base Act insurance and construction surety will be required.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
396.90
397.30
397.20
397.10
397.50 397.50
7.
7.
7.
7.
397.30397.20
7.
397.30
397.30
7.
397.10
397.20
397.20
7.
396.90
7.
7.
397.20
396.50 396.60 396.70 396.80
7.4
397.30
GYM
CAFE
CONSTRUCTION ZONE
CONSTRUCTION ZONE
DITCH
*ONLY HARDSTAND BUILDINGS
SHOWN, AS REQUESTED BY TFE.
FORCE PROVIDER TENTS,
EQUIPMENT, CONEX'S AND OTHER
TEMPORARY EQUIPMENT IS NOT
SHOWN.
397.119
397.020
396.847
396.616
396.681
396.719
396.677
396.746
397.090
SURVEY LIMIT
1 2 3 4 5 6 7 8
A
B
C
D
E
F
16th EN
GI
NE
ER
BR
IG
AD
E
Su rve y & D es ign
Se cti on
Bu ildi ng
Ca mp
Bu eh rin g ♦
Ku wa it ♦ Ph on e:
(31 8)
4-2
2 ♦
OIC:
Drawn By:
Surveyed By:
Survey Date:
Plot Date:
Sheet Number:
Sh ee t N am e:
Pr oj ec t N am e:
R
EV
IS
ED
B Y:
D
AT
E:
R
EV
IS
IO
N
D
ES
C R
IP
TI
O N
NCOIC:
LO
C
AT
IO
N : D
ES
KT
O P-
1K
H
PT
T:
\2 1-
-0
_E
AB
-L
SA
R
O
BE
R
TS
D
FA
C S
U R
VE
Y\
_D
R
AW
IN
G
S\
_D W
G \0
1_ D
R
AF
T\
-8 1-
9L
SA
R
O
BE
R
TS
D
FA
C S
H
EE
TS
.d w g
PL
O
TT
ED
: 2 0-
M ar
-2
:2
6:
20 Mar 2021
LS
A
R O
BE
R
TS
D
FA
C
ER
BI
L
AI
R
BA
SE
, I
R
AQ
CPT CURRIE
SGT TUCKER
SGT TUCKER
17MAR2021
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
SPC NEYER
C-101SCALE: 1:400A1 EXISTING CONDITIONS Meters
0 25 50
CAST IRON MANHOLE
COVER.
STRUTS
IF REQUIRED
BY KTR DESIGN.
PROVIDE PVC
WATERSTOP
(TYP)
TANK PENETRATIONS
FOR PIPING
(BY KTR DESIGN)
M
I N
M I N
I M
U M
T
A N
K
D
E P
T H
OPTION OF BASE EXTENSION
FOR PREVENTING UPLIFT
SEE NOTES
PROVIDE BITUMINOUS
COATING ON ALL SURFACES
OF TANK INTERIOR
LENGTH BY KTR DESIGN
MUST MEET CAPACITY REQUIREMENTS
SEE MECHANICAL FOR
PIPING AND PLUMBING
REQUIREMENTS
KTR PROVIDE
ACCESS LADDER
REINFORCEMENT NOT SHOWN
PROVIDE IN ACCORDANCE
WITH KTR DESIGN
(MIN)
600MM DIAMETER
MANHOLE OPENING
(MIN)
CHAM,FER CORNERS
(OPTIONAL BY KTR DESIGN)
KTR IS RESPONSIBLE FOR PROVIDING
THE NECESSARY PENETRATIONS
FOR ALL PIPING AS NEEDED FOR A
FULLY FUNCTIONAL SYSTEM.
C O
V E
R
S
P A
N
S
H A
L L
N O
T
B
E
G
R E
A T
E R
H A
N
DETAIL NOTES
1. KTR SHALL PROVIDE A 100% DESIGNED CONCRETE
SEPTIC TANK.
2. A CAST IN PLACE SYSTEM IS AN OPTION, THE KTR
MAY PROPOSE A PRECAST TANK SYSTEM AS LONG
AS ALL REQUIREMENTS ARE MET.
3. CONCRETE SHALL BE IN ACCORDANCE WITH S-001.
4. PROVIDE A STEEL LADDER AS INDICATED. LADDER
RUNGS SHALL BE GALVANIZED FOR CORROSION
PROTECTION AND SHALL HAVE A KNURLED
SURFACE PROFILE ON THE STEP TO PREVENT
SLIPPING.
5. THE OPTION SHOWN FOR EXTENDING THE BASE
OF THE TANK IS NOT MANDATORY WITHIN THE
DESIGN BUT SIMPLY SHOWN TO COMMUNICATE
THAT UPLIFT NEEDS TO BE ADDRESSED. UPLIFT
BELOW THE TANK IS GREATLY DEPENDENT ON
SOIL PROPERTIES AND BACKFILL CONDITIONS.
THE DESIGNER OF RECORD SHALL ENSURE UPLIFT
IS ADDRESSED WITHIN THE DESIGN
CALCULATIONS FOR BOTH THE CONSTRUCTION
LOAD CASE AS WELL AS WHEN THE TANK IS IN
SERVICE AND EMPTY. THE LIST BELOW ARE WAYS
IN WHICH THE DOR MAY ADDRESS UPLIFT.
5.1. SHOW THE SOIL CONDITIONS OF THE AREA
ARE NOT PERMEABLE AND WILL REDUCE OR
PREVENT HYDROSTATIC PRESSURES UNDER
THE TANK.
5.2. DESIGN THE TANK FOR FULL HYDROSTATIC
PRESSURE AND DESIGN A METHOD FOR
PREVENTING TANK POP OUT THROUGH AN
EXTENDED FOOTING, DEAD MAN, ANCHOR,
THICKER BASE, ETC.
MINIMUM
ALL SIDES
MIN
M
I N
REINFORCMENT SHALL
BE BY KTR DESIGN
ANCHOR BOLTS
SHALL BE IN
ACCORDANCE
WITH
MANUFACTURER
FUEL TANK
SEE MECHANICAL
DETAIL NOTES
1. TANK SHALL BE IN ACCORDANCE WITH
MECHANICAL SECTION REQUIREMENTS
2. ANCHOR BOLTS SHALL BE DESIGNED IN
ACCORDANCE WITH CHAPTER 15, ASCE 7.
3. THE VOLUME OF SPACE WITHIN THE
SECONDARY CONCRETE CONTAINMENT
SHALL BE EQUAL 110% OF THE TANKS FULL
CAPACITY.
4. REINFORCEMENT SHOWN IS NOT FOR
CONSTRUCTION. KTR SHALL DESIGN THE
SECONDARY CONTAINMENT AND PROVIDE
DESIGN FOR GOVERNMENT APPROVAL.
S-201
C O
N C
R E
C
O N
T A
I N
M E
N
R
U C
T U
R E
S
M
E
L L I S
P
E
M
E
L L I S
P
E
T F
E
SCALE: NTS
PLAN VIEW - SEPTIC TANK
D7
SCALE: NTS
ELEVATION VIEW - SEPTIC TANK
A7
SCALE: NTS
ELEVATION VIEW - SECONDARY FUEL CONTAINMENT
A1
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N
A
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D A
T E
C O
N T
R A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
US Army Corps of Engineers
R O
B E
R T
S
D
F A
C
E R
B I L
B
I R
A Q
T A
K
F
R
S
A Y
O N
S
Location: J:\Design Branch\Design Projects\Erbil\2020-0088 Construct Roberts DFAC\2. CAD\2020-0088 Roberts DFAC - S-201.dwg Plotted: 8 February 2021 11:20:18
M
Y
C
O R
P
E
N G
I N
E E
R S
T R
A N
S A
T L
A N
T
D
V
I S
I O
N
W I N
C H
E S
T E
R
V
T A
R
S
A Y
O N
S
C A
M P
I F
J A
N
A R
I F
J A
N
K
U W
A I T
T A
R
S
A Y
O N
S
A N
S I
D
F e b
R o b e r t s
D
F A
C
S d w g
P R
O J E
1390mm
900mm m m m m m m
876mm m m
320mm m m
L m m
L m m
200mm 200mm
1100mm
820mm m m m m m m m m
70mm 70mm 70mm
330mm
70mm
330mm
70mm 70mm
203mm m m m m
1500mm
380mm 380mm m m
H m m m m m m
(TYPE 2)
(#4 @ 200mm O.C.)
15Ø @ 200mm O.C.
(TYPE 3)
(#4 @ 200mm O.C.)
15Ø @ 200mm O.C.
(TYPE 6)
(#4 @ 200mm O.C.)
15Ø @ 200mm O.C.
(TYPE 6)
(#4 @ 200mm O.C.)
15Ø @ 200mm O.C.
(TYPE 7, SEE NOTE 2)
25Ø (#8 BAR)
(TYPE 1)
15Ø @ 200mm O.C. (#4 @ 200mm O.C.)
(TYPE 4)
15Ø @ 200mm O.C. (#4 @ 200mm O.C.)
m m
BARRIER
(SEE NOTE 5)
MINIMUM100mm THICK BASE
EXISTING GROUND
m m m m
SEE NOTE 2
SEE NOTE 2
(TYPE 5)
25Ø (#8 BAR) LIFTING EYE
m m m m m m m m m m
300mm
240mm
160mm
160mm m m m m m m m m
240mm
(SEE NOTE 8)
PIPE SLEEVE (SEE NOTE 8)
PIPE SLEEVE
300mm
84003.5053805500EXTRA - LARGE
72003.0044804600LARGE
60002.5035803700STANDARD
(kg)
WEIGHT
(m³)
VOL.
CONC.
LHSIZE
SCHEDULE
D
IS
T R
IC
T
K
U W
A
IT
T R
A N
S A
T L
A N
T
IC
E X
P E
D
IT
IO
N
A
Y
.S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D A
T E
DISTRICT
EXPEDITIONARY
TRANSATLANTIC
of Engineers
US Army Corps
A N
S I
D
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
C K
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E P
L O
T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
IDENTIFICATION
SHEET
D A
T E
A P
P R
D E
S
IG
N E
D B
Y
D W
N B
Y
IN
T
E R
L O
C K
IN
G
A L
A S
K A
B A
R R
IE
R
FP-01
N .T
.S
TYPE 2
(N.T.S.)
TYPE 3
(N.T.S.)
TYPE 1
(N.T.S.)
TYPE 4
(N.T.S.)
TYPE 6
(N.T.S.)
TYPE 7
(N.T.S.)
TYPE 5
(N.T.S.)
PLAN VIEW
(N.T.S.)
ELEVATION
(N.T.S.)
SECTION
(N.T.S.)
CABLE CONNECTION DETAIL
(N.T.S.)
REBAR TYPES
NOTES
THE STEEL SHALL BE 420N/mm².
10) REINFORCEMENT SHALL BE ASTM-A615, GRADE 60. YIELD STRENGTH OF
BE AT 4500 PSI AFTER 28 DAYS.
9) CONCRETE TYPE SHALL BE 4500 PSI. THE COMPRESSIVE STRENGTH SHALL
8) ONLY FOR BARRIERS THAT REQUIRE PIPE THROUGH FOR REMOTE PUMPING.
FOR CABLES AT END CAPS. SEE DETAIL "CABLE CONNECTION DETAIL".
CABLE, ASPHALT BITUMINOUS COATING. TURN BUCKLES SHALL BE INSTALLED
7) CABLE SHALL BE 19mm 6x19 CLASS FIBER CORE, IMPROVED PLOW STEEL
6) ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE.
STONE AGGREGATE OR SOLID PAVING.
5) ALL BARRIER SEGMENTS MUST BE PLACED ON COMPACTED DENSE CRUSHED
4) PROVIDE 20mm CHAMFER TO ALL EXPOSED CONCRETE CORNERS, TYPICAL.
3) MINIMUM 4cm (1.5") CLEAR COVER.
LIFTING EYE.
2) COUNTER MOBILITY CABLE ANCHORAGE THAT CAN ALSO BE USED AS
1) MAIN REINFORCEMENT NOT SHOWN IN PLAN AND ELEVATION FOR CLARITY.
BASE SECTION
(N.T.S.)
A L
A S
A D
IR
A Q
G R
E Y
E A
G L
E C
R E
W O
F F
IC
E
P
A T
R
IC
K R
G
R E
Y
P .R
.G
P .R
.G
B R
IA
N
R J O
H N
S O
N
S E
P T
| 01_Roberts DFAC G-001 |
| 02_Roberts DFAC G-002 |
| 03_Roberts DFAC G-003 |
| 20_Roberts DFAC C-101 |
| 21_Roberts DFAC C-102 |
| 22_Roberts DFAC C-103 |
| 23_Roberts DFAC C-301 |
| 24_Roberts DFAC C-302 |
| 30_Roberts DFAC S-101 |
| 31_Roberts DFAC S-102 |
| 40_Roberts DFAC A-501 |
| 41_Roberts DFAC A-502 |
| 42_Roberts DFAC A-503 |
| 50_Roberts DFAC M-101 |
| 51_Roberts DFAC M-102 |
| 2020-0088 Roberts DFAC - S-205.pdf |
| Sheets and Views |
| S-205 |
| 2020-0088 Roberts DFAC - S-201.pdf |
| Sheets and Views |
| S-201 |
| 21-81-079_LSA ROBERTS DFAC_SHEETS.pdf |
| Sheets and Views |
| 21-81-079LSA ROBERTS DFAC SHEETS-G-001 COVER SHEET |
| Sheet 1 |
| 21-81-079LSA ROBERTS DFAC SHEETS-C-101 PLAN SHEET (3) |
| Sheet 1 |
File details come from the government source that posted it. Updated .