ALTERNATE Southwire Cut Sheet SW-1003814_DL.pdf

PDF 449 KB Posted

Attached to
Market Survey for Procurement of NSN’s 6150-01-700-9145, CABLE ASSEMBLY, POWER, ELECTRICAL, and 6150-01-700-9148, CABLE ASSEMBLY, POWER, ELECTRICAL
Solicitation number
DLA-Aberdeen-25-035
Issued by

About this file

This document is a Southwire product cut sheet for a 20A User Attachable Ground Fault Circuit Interrupter (GFCI) device designed for various industrial and commercial applications. The yellow-colored Shockshield in-line GFCI is available in two models: 25230001-6 (120V, 20A) and 26000200-6 (240V, 20A), both accepting 18-12 AWG cord gauges. Key technical specifications include a trip point up to 30mA, less than 25ms trip response time, manual reset functionality, and an operating temperature range of -35˚C to 66˚C. The device can be easily attached to supply cables 9-10 inches from the plug end and is suitable for equipment such as pressure washers, drain snakes, floor cleaners, industrial appliances, power tools, and extension cords.

The product is UL listed and features technical capabilities including a grounded neutral of 4 ohms, voltage surge withstand of 3 Kv, radio frequency noise susceptibility within normal limits, and endurance of 3,000 minimum operations. The GFCI has an overload current capacity of six times the rated current and includes a lighted power indication. The cut sheet is part of a market survey by the Defense Logistics Agency-Aberdeen, which intends to procure 500 units of specific National Stock Number (NSN) cable assemblies to support the Combat Service Support Very Small Aperture Terminal (CSS-VSAT) AN/TSC-183A system, with responses requested by 01 April 2025.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1-855-798-6657 | SOUTHWIRE.COM

©2023 Southwire Company, LLC. All rights reserved.

*Registered Trademark & ™Trademark of Southwire Company, LLC.

TRIP POINT UP TO 30MA

MANUAL RESET

LESS THAN 25MS TRIP

RESPONSE TIME

CAN BE EASILY ATTACHED BY

CONNECTING THE GFCI IN SERIES

WITH THE SUPPLY CABLE 9 TO 10

INCHES FROM THE PLUG END TO

PROVIDE GFCI PROTECTION

APPLICATIONS: OEM / CUSTOM

CORD SET

Shockshield in-line user attachable for OEM connection of cable.

20A USER ATTACHABLES

APPLICATIONS

Pressure Washers

Drain Snakes

Floor Cleaners

Industrial Appliances

Power Tools

Bumps

Extension Cords

MODEL #

ELECTRICAL

RATING

CORD GAUGE ENCLOSURE COLOR TRIP LEVEL

25230001-6 120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA

26000200-6 240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA

TECHNICAL DATA

GROUNDED NEUTRAL 4 Ohms Typical

VOLTAGE SURGE WITHSTAND 3 Kv Ringwave Test and 4Kv/2Ka Surge Immunity Test

RADIO FREQUENECY NOISE SUSCEPTABILITY Operates Within Normal Limits With 0.5 Volts Injected On Power Line 150Khz-230Mhz

ENDURANCE 3,000 Operations Minimum

OVERLOAD CURRENT Six Times Rated Current

OPERATING TEMPERATURE RANGE -35˚C to 66˚C

EFFECT OF 10 AMP TURN DC SOCK FAULT TRIP 5% Maximum Trip Level Variation on Ground

INSULATION VOLTAGE 1500 Vrms - 1 Min.

POWER INDICTATION Lighted Indicator

25230001-6