Regarding Brand Name or Equal provision (52.211-6), the salient characteristics of the PVC Membrane Roofing include, but are not limited to: 60 mils (1.5 mm) minimum; Color: White; Energy Performance: Provide roofing system with initial solar reflectance not less than 0.83 and emissivity not less than 0.87 when tested according to CRRC-1; Type III PVC Sheet roofing as defined by ASTM D4434-96 and must meet or exceed the following physical properties:
Thickness over scrim: 28 mil (.028) minimum, ASTM D4434 optical method.
Scrim Water Absorption: Non-wicking scrim with no requirement for seam sealant on non-factory (cut) edges.
Contractor shall consult Section 07541 for entire specifications.