SITE_VISIT_QUESTIONS.pdf
PDF 10 KB Posted
- Solicitation number
- AG-8KAP-S-16-0002
About this file
Site Visit Questions and Statement of Work Clarifications
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SOLICITATION_AMENDMENT__001.pdf | ||
| Eave.PNG | PNG image | |
| DAVIS_BACON_WAGE_DETERMINATION.pdf | ||
| Shop__004-eml.jpg | JPG image | |
| STATEMENT_OF_WORK.pdf | ||
| Rake_Trim.PNG | PNG image | |
| Shop__005-eml.jpg | JPG image | |
| Barn_002-eml.jpg | JPG image | |
| Pro-Panel_II.PNG | PNG image | |
| Shop__002-eml.jpg | JPG image | |
| Cheyenne_Shop_1-3_ _Barn_4-6.pdf | ||
| SOLICITATION__AG-8KAP-S-16-0002.pdf | ||
| Shop__001-eml.jpg | JPG image | |
| 20_inch_Ridge_Cover.PNG | PNG image | |
| CATEGORIES_OF_BIO-BASED_PRODUCTS.pdf | ||
| Barn_003-eml.jpg | JPG image | |
| Barn_001-eml.jpg | JPG image | |
| Shop__003-eml.jpg | JPG image |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Site Visit Questions and Statement of Work Clarifications:
1. Can Feltex be substituted for the tar paper?
a. Yes, as long as it is of equal or better quality that the required tar paper.
2. In regards to the chimneys, could the contractor be allowed to remove them and use solid roofing in their place?
a. No, the chimneys need to stay as they are.
3. Should copper flashing be used with the tin?
a. No, copper flashing should NOT be used and is hereby removed from the statement of work. The chimney flashing shall be of a weight and size to suit the seam locations.
4. Is there a requirement for an air gap between the metal roofing and the felt paper or is it acceptable to have the metal roofing in direct contact with the felt paper?
a. There is no requirement for an air gap. It is acceptable to have the metal roofing in direct contact with the felt paper.
5. Is Metal Sales prefinished steel acceptable for the “metal drip edge made of aluminum” specified in the Statement of Work?
a. Yes it is acceptable; aluminum is NOT required and is hereby removed from the statement of work.
6. Does an ice and water shield need to be used?
a. It is not required under the Statement of Work, but the roof needs to be in compliance with whatever local code requires.
7. Are there other layers of roofs under the shake?
a. No