Attachment_03_-_Drawings.pdf
PDF 7 MB Posted
- Attached to
- Duchesne Bunkhouse Construction Federal contract opportunity
- Solicitation number
- AG-84N8-S-14-0052
About this file
Attachment 03 - Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| AG-84N8-S-14-0052_0002.pdf | ||
| Questions_and_Answers.docx | DOCX document | |
| AG-84N8-S-14-0052_0001.pdf | ||
| Questions_and_Answers.docx | DOCX document | |
| Site_Visit_Attendees.pdf | ||
| Attachment_07_-_AGAR_452.209-70.docx | DOCX document | |
| Attachment_04_-_Wage_Detemination.pdf | ||
| Attachment_01_-Schedule_of_Items.pdf | ||
| Attachment_05_-_Geotechnical_Report.pdf | ||
| Attachment_02_-_Specifications.docx | DOCX document | |
| Attachment_06_-_Subcontractor_Reporting_Form.docx | DOCX document | |
| AG-84N8-S-14-0052.docx | DOCX document |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
fo r D av id J ep ps en
4/ 3/
4/ fo r D av id J ep ps en fo r D av id J ep ps en alanmckean Typewritten Text alanmckean Typewritten Text alanmckean Typewritten Text alanmckean Typewritten Text alanmckean Typewritten Text fo r D av id J ep fo r D av id J ep fo r D av id J ep fo r D av id J ep
D av id J ep fo r D av id J ep
D av id J ep fo r D av id J ep fo r D av id J ep fo r D av id J ep fo r D av id J ep fo r D av id J ep
D av id J ep fo r D av id J ep fo r D av id J ep fo r D av id J ep fo r D av id J ep fo r D av id J ep
FIRE SPRINKLER
FLOW SENSOR
CONNECT TO AND
ACTIVATES BELL
ONLY
SPRINKLER FLOW
ALARM BELL
A
A
A
A
A
A
BB
B
B
BB
B
A AA
A AA
B B
B
B
B
B
D
E E
C
M
M
A-4
A-4
A-4
A-4
A-4
A-10 A-10
A-10
A-10A-12
A-11
A-12+14
A-20
A-16,18
A- 13+15 A-17,19
A-21A-22
UNDER SINK FOR
DISHWASHER
A-4
A-23 A-23
A-23
A-23
A-23
J
J
A-24A-25
A-24
A-24 A-24A-25
A-25
A-25
A-29
A-26
A-26
A-26
A-27
A-28
A-29
A-29
A-29 A-30
A-30 A-30 A-30
A-22
A-22
A-22
A-31
A-31
A-31
A-31
A-31
A-31
A-31
A-31
A-23
A-23
SEE LEGEND FOR MORE
INFORMATION
SPLIT WIRE THE 20 AMP,
120 VAC RECEPTACLE
FOR 2 CIRCUITS,
MULTIWIRE IS ALLOWED
IN THESE CASES ONLY.
G
A-23
A-31
MOUNT BOTH TV
AND RECEPTACLE
AT 48" TO CENTER
ABOVE FINISHED
FLOOR.
MOUNT LIGHT ABOUT 12
FEET ABOVE FINISHED
GRADE.
SURGE SUPPRESSION FOR
SATELLITE TV ENTRANCE WITH
LOCAL GROUNDING ELECTRODE
AND BOND BACK TO ELECTRICAL
SERVICE.
GENERAL ELECTRICAL NOTES
THE WORK AT THE SITE INCLUDES:
1. COORDINATING ALL CUSTOMER REQUIRED WORK AND EQUIPMENT TO COMPLY WITH MOON
LAKE ELECTRIC (435-722-5400) REQUIREMENTS AND PROJECT SPECIFICATIONS TO PROVIDE
FOR UNDERGROUND ELECTRICAL SERVICES AND WITH STRATA NETWORKS (345-622-5007) FOR
PHONE AND RELATED SERVICES. VERIFY SERVICE ENTRANCE LOCATIONS WITH BUILDING
SITING IN COORDINATION WITH UTILITY PROVIDERS. SHEET W1 SHOWS UTILITY POLE
LOCATIONS THAT MOON LAKE ELECTRIC MAY USE FOR BEGINNING THE SERVICE LATERAL.
2. PROVIDE A 36-INCH MINIMUM TRENCH DEPTH WITH A MINIMUM BURIAL DEPTH OF 30-INCHES
PER POWER COMPANY BEDDING AND BACKFILL REQUIREMENTS. SERVICE SHALL BE KEPT
36-INCHES FROM WATER OR GAS SERVICES.
3. ELECTRICAL SERVICE EQUIPMENT SHALL BE RATED FOR 200 AMP MINIMUM AND 22,000 SHORT
CIRCUIT CURRENT RATED (MAY BE SERIES RATED), EQUIVALENT TO SQUARE D HOMELINE OR
BETTER, NO TANDEM OR HALF SIZED BREAKERS ALLOWED.
4. ELECTRICAL SERVICE METERBASES SHALL BE INSTALLED WITH IMC AND SWEEP PER
SPECIFICATIONS, WITH CENTER OF METER LOCATED BETWEEN 5 AND 6-FEET ABOVE
FINISHED GRADE.
5. PROVIDE A 2-INCH CONDUIT FROM STRATA NETWORK APPROVED LOCATION FOR
PHONE/INTERNET SERVICE. DIRECT BURIED CABLE(S) THAT WILL MEET REQUIREMENTS FOR
ALL THREE SERVICES INSTALLED BEFORE CONTRACT IS COMPLETE MAY SUBSTITUTE FOR
THE CONDUIT. CONDUIT OR CABLES SHALL BE BURIED 24-INCHES MINIMUM. IF SERVICE
POINT IS AT THE POWER COMPANY POLE SHOWN IT MAY BE INSTALLED IN THE SAME TRENCH
AS THE ELECTRICAL SERVICE AT 30-INCHES MINIMUM. KEEP SEPARATE FROM POWER
COMPANY INSTALLED SECONDARY A MINIMUM OF 12-INCHES.
6. PHONE SERVICE SHALL BE BROUGHT INTO THE BUILDING NEXT TO THE ELECTRICAL SERVICE.
HOME RUN EACH EACH INTERNAL PHONE TO THIS LOCATION INTO COMBINER/SERVICE BOX.
LABEL EACH RUN IN A PERMANENT AND UNDERSTANDABLE MANNER. GROUND PER CODE
AND SPECIFICATIONS.
7. TELEVISION SERVICE SHALL BE SATELLITE BASED WITH DISH AND CABLE TO DISH FROM
SURGE ARRESTOR/GROUNDING POINT BY OTHERS. GROUND PER CODE, SPECIFICATIONS,
AND AS SHOWN.
8. ELECTRICAL IN HOUSING SHOWN IS A MINIMUM AND MAY VARY BASED ON SUBMITTED FLOOR PLANS. IF ALTERNATIVE SIZED BUILDING IS APPROVED, ELECTRICIAN SHALL SUBMIT MODIFIED
ELECTRICAL PLAN. ADDITIONAL LUMINAIRES AND OR TYPE CHANGES MAY BE REQUIRED AT
NO COST TO PROVIDE THE SAME LEVEL OF SERVICE. ADDITIONAL RECEPTACLES MAY BE
REQUIRED TO MEET INTENT AS SHOWN.
9. LOAD CENTER LOCATION(S) ARE NOT SHOWN. LOCATE IN HALLWAYS OR OTHER COMMON
WALL SPACE NOT CONFLICTING WITH OTHER USE, SUBJECT TO APPROVAL BEFORE
INSTALLATION BY CONTRACTING OFFICER.
10. SMOKE, CARBON DIOXIDE, VISUAL, AND COMBINATION ALARMS SHALL ALL BE
INTERCONNECTED.
RV PARKING OPTION
11. SEE SHEET W1 FOR SITE PLAN SHOWING THE LOCATIONS OF 3 TRAILER PEDESTALS TO BE
SERVED FROM A COMMON ELECTRICAL SERVICE SEPARATE FROM THE BUNKHOUSE.
12. INSTALL SEPARATE ELECTRICAL SERVICE AS CALLED FOR WITH ALL-IN-ONE COMBINATION
SERVICE ENTRANCE DEVICE.
13. PROVIDE ELECTRICAL POWER ONLY TO EACH PAD FROM COMMON SERVICE AS SHOWN. NO
PHONE OR OTHER RELATED SERVICES SHALL BE PROVIDED AT THE PADS. RV PEDESTALS
SHALL BE SQUARE D PAK75PG OR EQUAL. CIRCUITS SHALL BE HOME RUN SIZE 1" CONDUIT
WITH 3#6 THWN AND 1 #10 GROUND.
CRAWL SPACES AND ATTIC SPACES LIGHTING AND RECEPTACLES
1- AT EACH CRAWL OR ATTIC ACCESS, INSTALL ONE GFCI RECEPTACLE AND SWITCH ON THE CIRCUIT SERVING THE
ROOM WITH THE ACCESS.
2- WITHIN EACH CRAWL AND ATTIC SPACE SECTION INSTALL 2 TYPE "N" LUMINAIRES LOCATED TO LIGHT THE AREA.
LOCATIONS SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE INSTALLATION.
3- A CRAWL SPACE OR ATTIC ACCESS SECTION SHALL BE DEFINED AS MINIMALLY 1 PER BUILDING MAJOR AXIS WITH FIRE WALL SEPARATIONS OR OTHER SIMILAR BARRIERS CREATING ADDITION SECTIONS THAT SHALL HAVE
ACCESS, RECEPTACLE, AND SWITCH LOCATIONS.
LAMPS FOR SPOT LIGHT
LED PAR38 26W SHALL HAVE THE FOLLOWING MINIMUM SPECIFICATIONS: RATED 26 WATTS OR LESS, >1400 INITIAL LUMENS, 2700-3000 K COLOR TEMPERATURE, CRI>80, 25 DEGREE BEAM SPREAD, WET LOCATIONS RATED. GE
LIGHTING #68184 LED26DP38S830/25 MEETS THIS REQUIREMENT.
LOAD CENTER DISTRIBUTION
THE FOLLOWING IS A LIST OF COMMON CIRCUITS MINIMUM:
# AMPS DESCRIPTION
A-1 20 3 NORTHEAST BEDROOMS AND EXTERIOR LIGHTS AND
RECEPTACLES, NORTHEAST HALL AND EXTERIOR LIGHTS
A-2 20 3 NORTHWEST BEDROOMS LIGHTS AND RECEPTACLES, HALL AND
EXTERIOR RECEPTACLES
A-3 20 4 SOUTHEAST BEDROOMS LIGHTS AND RECEPTACLES, SOUTH SIDE
SOUTH HALL AND EXTERIOR RECEPTACLES
A-4 20 LIGHTS-BATHROOMS, MECH, SOUTH AND SOUTHEAST HALL,
STORAGE, JANITOR, MUDROOM, LAUNDRY, PANTRY
A-5 20 RECEPTACLE-EAST DORM BATHROOM NORTH SINK
A-6 20 RECEPTACLE-EAST DORM BATHROOM SOUTH SINK
A-7 20 RECEPTACLE-WEST DORM BATHROOM SOUTH SINK
A-8 20 RECEPTACLE-WEST DORM BATHROOM NORTH SINK
A-9 20 RECEPTACLE-ADA BATHROOM SINK
A-10 20 RECEPTACLE-SOUTHEAST HALL, NORTH SIDE SOUTH HALL, MECH,
JANITOR, MUDROOM, EXTERIOR
A-11 20 RECEPTACLE- SMALL BATHROOM
A-12+14 20 SPLIT CIRCUIT RECEPTACLE-WASHERS (MULTIWIRE)
A-13+15 20 SPLIT CIRCUIT RECEPTACLE- GAS DRYERS (MULTIWIRE)
A-16,18 30 RECEPTACLE-NORTH ELECTRIC DRYER
A-17,19 30 RECETPACLE-SOUTH ELECTRIC DRYER
A-20 20 RECEPTACLE-LAUNDRY COUNTER
A-21 20 RECEPTACLE-PANTRY ICE MACHINE
A-22 20 RECEPTACLE-PANTRY, KITCHEN NORTH WALL
A-23 20 LIGHTS-KITCHEN, EXTERIOR AND SITE, COMMON AREA,
RANGEHOODS
A-24 20 RECEPTACLE-EAST COUNTERS, FRIDGE
A-25 20 RECEPTACLE-SOUTHEAST COUNTERS, EAST STOVE
A-26 20 RECEPTACLE-ISLAND
A-27 20 RECEPTACLE-EAST DISHWASHER
A-28 20 RECEPTACLE-WEST DISHWASHER
A-29 20 RECEPTACLE-SOUTH COUNTER WEST SIDE
A-30 20 RECEPTACLE-WEST COUNTER, FRIDGE
A-31 15 RECEPTACLE- COMMON ROOM, EXTERIOR
A-32 15 SMOKE ALARMS, ALARM BELL CIRCUIT
OTHER CIRCUITS THAT ARE NOT SHOWN INCLUDE BUT ARE NOT LIMITED TO:
FIRE PUMP DISCONNECT AND PROTECTION IF REQUIRED SHALL BE BEFORE THE
BUILDINGS MAIN.
FURNACE(S) AND SINGLE POLE SWITCH DISCONNECTS
AIR CONDITIONER(S) AND GENERAL DUTY DISCONNECTS
WATER HEATER(S) - GAS WATER HEATERS WITH SMALL LOADS MAY BE PLACED ON
OTHER CIRCUITS.
REQUIRED CRAWL SPACE AND ATTIC SPACE LIGHTING AND RECEPTACLES AS
DESCRIBED MAY BE PLACED ON OTHER CIRCUITS.
THE SITE LIGHT (SEE SITE PLAN) IS SHOWN ON CIRCUIT A-23.
HAND DRYER CIRCUITS A-7 AND A-10 REQUIRE FIXED-IN PLACE, HANDLE PADLOCK
ATTACHMENTS ON CIRCUIT BREAKERS.
fo r D av id J ep
FIRE SPRINKLER
A
A-1
A-1
A-1
A-1
A-1
S
A
A-1
A-1
A-1
A-1
A-1
S
A
A-1
A-1
A-1
A-1
A-1
S
A
A-2
A-2
A-2
A-2
A-2A
A-2
A-2
A-2
A-2
A-2A
A-2
A-2
A-2
A-2
A-2
A
A-3
A-3
A-3
A-3
A-3
S
A
A-3
A-3
A-3
A-3
A-3
S
A
A-3
A-3
A-3
A-3
A-3
S
A
A-3
A-3
A-3
A-3
A-3
B
BB B B B B B B
C
E
D
D
F
F
M
M
M
A-1
A-1
A-1
A-2
A-2
A-3
A-3
A-4
A-4
A-4
A-4
A-4
A-4A-4
A-4
A-5
A-6
A-10 A-8A-7A-10
A-9
A-10
C
SS
B
F
F
A-4
A-4
F
F
A-4
A-4
A-10 A-2
A-1
S
S
C
M M
SERVICE CALCULATIONS
NEC 220.82
(3VA/FT2)(~3860FT2)= 11,580
(1.5KW)(6 SMALL APPL)= 9,000
(1.5KW)(2 LAUNDRY)= 3,000
TOTAL= 23,580
3,000 @ 100%= 3,000 20,580 @ 35%= 7,203
TOTAL= 10,203
ICE MAKER= 1,400
2 FREEZERS= 1,200
2 DISHWASHERS= 2,060
2 DISPOSALS= 1,380
TOTAL= 6,040
4+ APPLIANCES @75%= 4,530
2 DRYERS DEMAND LOAD= 10,000
TOTAL VA= 24,733
OTHER LOADS THAT SHALL BE INCLUDED:
FURNACE MOTORS @ 75%
A/C CONDENSERS @ 100%
SERVICE SHALL BE 200 AMP MINIMUM
WITH FULL SIZED NEUTRAL.
fo r D av id J ep
FINISH GRADE
4"
24"
CONCRETE
6"x6"
PRESSURE
TREATED
WOOD
POST
(TYPICAL)
UNISTRUT
SUPPORT
(TYPICAL)
ALL-IN-ONE
COMBINATION
SERVICE
ENTRANCE
WITH METER
HEIGHT PER
MOON LAKE
REQUIREMENTS