SECTION 07610 - SHEET METAL ROOFING
PART 1 - GENERAL
1.1 SUMMARY
A. This Section includes the following custom-fabricated sheet metal roofing:
1. Standing-seam metal roofing.
1.2 PERFORMANCE REQUIREMENTS
A. General: Provide complete sheet metal roofing system, including, but not limited to, cleats, clips, anchors and fasteners, sheet metal flashing and drainage components related to sheet metal roofing, fascia panels, trim, underlayment, and accessories as indicated and as required for a weathertight installation.
Delete first paragraph below if UL Class 90 wind-uplift resistance for roll-formed sheet metal roofing is not required. Verify that portable roll-forming equipment manufacturers retained in Part 2 are listed in UL's "Roofing Materials & Systems Directory."
B. Wind-Uplift Resistance: Provide sheet metal roofing assemblies that comply with UL 580 for Class 90 wind-uplift resistance.
C. Thermal Movements: Provide sheet metal roofing that allows for thermal movements resulting from changes in ambient and surface temperatures by preventing buckling, opening of joints, hole elongation, overstressing of components, failure of joint sealants, failure of connections, and other detrimental effects. Provide clips that resist rotation and avoid shear stress as a result of sheet metal roofing thermal movements. Base engineering calculation on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss.
Differential values below (for aluminum in particular) are suitable for most of the U.S. Revise to suit local conditions.
1. Temperature Change (Range): 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.
D. Water Infiltration: Provide sheet metal roofing that does not allow water infiltration to building interior, with metal flashing and connections of sheet metal roofing lapped to allow moisture to run over and off the material.
1.3 SUBMITTALS
Retain first paragraph below only for underlayment materials, snow guards, and miscellaneous materials.
A. Product Data: For each product indicated. Include details of construction relative to materials, dimensions of individual components and profiles, and finishes.
Coordinate first paragraph below with qualification requirements in Division 1 Section "Quality Requirements" and as supplemented in "Quality Assurance" Article.
B. Qualification Data: For Installer.
1.4 QUALITY ASSURANCE
A. Installer Qualifications: Employed by, or fabricator of sheet metal roofing.
B. Custom-Fabricated Sheet Metal Roofing Fabricator Qualifications: Shop that employs skilled workers who custom-fabricate sheet metal roofing similar to that required for this Project and whose products have a record of successful in-service performance.
C. Sheet Metal Roofing Standard: Comply with SMACNA's "Architectural Sheet Metal Manual." Conform to dimensions and profiles shown unless more stringent requirements are indicated.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Deliver components, and other sheet metal roofing materials so as not to be damaged or deformed. Package sheet metal roofing materials for protection during transportation and handling.
B. Unload, store, and erect sheet metal roofing materials in a manner to prevent bending, warping, twisting, and surface damage.
C. Stack materials on platforms or pallets, covered with suitable weathertight and ventilated covering. Store sheet metal roofing materials to ensure dryness. Do not store sheet metal roofing materials in contact with other materials that might cause staining, denting, or other surface damage.
D. Protect strippable protective covering on sheet metal roofing from exposure to sunlight and high humidity, except to extent necessary for period of sheet metal roofing installation.
1.6 COORDINATION
A. Coordinate sheet metal roofing installation with installation of roof support structural steel framing by others.
1.7 WARRANTY
A. Special Warranty on Finishes: Manufacturer's standard form in which manufacturer agrees to repair finish or replace sheet metal roofing that shows evidence of deterioration of factory-applied finishes within specified warranty period.
1. Fluoropolymer Finish: Deterioration includes, but is not limited to, the following:
a. Color fading more than 5 Hunter units when tested according to ASTM D 2244.
b. Chalking in excess of a No. 8 rating when tested according to ASTM D 4214.
c. Cracking, checking, peeling, or failure of paint to adhere to bare metal.
2. Finish Warranty Period: 20 years from date of Substantial Completion.
B. Special Installer's Warranty: Roofing Installer's warranty, on warranty form at end of this Section, signed by Roofing Installer, in which Roofing Installer agrees to repair or replace components of custom-fabricated sheet metal roofing that fail in materials or workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Structural failures.
b. Loose parts.
c. Wrinkling or buckling.
d. Failure to remain weathertight, including uncontrolled water leakage.
e. Deterioration of metals, metal finishes, and other materials beyond normal weathering, including nonuniformity of color or finish.
f. Galvanic action between sheet metal roofing and dissimilar materials.
2. Warranty Period: Two years from date of Substantial Completion.
1.8 MEASUREMENT AND PAYMENT
This item shall include the standing seam metal roofing, flashings and trim as shown on the plans. Work shall include fabrication, installation, trim, flashings, touchup, cleanup, and all associated work for a complete and functional installation as shown on the drawings.
Measurement for this work shall be one lump sum item for the work, completed and installed in accordance with the plans and specification. Payment for work in this section will be made at the contract lump sum price as shown on the Schedule of Items, including all materials, delivery, labor, and incidental items.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
See Editing Instruction No. 1 in the Evaluations for cautions about naming manufacturers and products.
Edit this Article with other Part 2 articles in which manufacturers and products, or manufacturers only, are named. See Division 1 Section "Product Requirements" for an explanation of the terms "Available Products," "Products," "Available Manufacturers," and "Manufacturers" and the effect these terms have on "Comparable Product" and "Product Substitution" requirements.
A. In other Part 2 articles where titles below introduce lists, the following requirements apply for product selection:
1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the products specified.
2.2 ROOFING SHEET METALS
A. Metallic-Coated Steel Sheet Pre-painted with Coil Coating: Steel sheet metallic coated by the hot-dip process and pre-painted by the coil-coating process to comply with ASTM A 755/A 755M.
1. Zinc-Coated (Galvanized) Steel Sheet: ASTM A 653/A 653M, G90 (Z275) coating designation; structural quality.
2. Surface: Smooth, flat finish.
3. Thickness: 0.0276 inch (0.7 mm), unless otherwise indicated.
4. Exposed Finishes: Apply the following coil coating, as specified or indicated on Drawings:
a. High-Performance Organic Finish: Prepare, pre-treat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions.
First subparagraph below references AAMA standard for high-performance organic coating spray-applied on aluminum extrusions and panels. Manufacturers of metallic-coated steel sheet also use this standard for both spray-applied and coil-coated fluoropolymer finishes. Revise if specific products are required. AAMA 2604 provides a 5-year performing finish; AAMA 2605, 10 years. See Evaluations.
1) Fluoropolymer Two-Coat System: Manufacturer's standard two-coat, thermocured system consisting of specially formulated inhibitive primer and fluoropolymer color topcoat containing not less than 70 percent polyvinylidene fluoride resin by weight; complying with physical properties and coating performance requirements of AAMA 2605, except as modified below:
a) Humidity Resistance: 2000 hours.
b) Salt-Spray Resistance: 2000 hours.
Delete subparagraph and associated subparagraphs above or below; if both are required, indicate location of each system on Drawings, in schedules, or by inserts.
2) Fluoropolymer Three-Coat System: Manufacturer's standard three-coat, thermocured system consisting of specially formulated inhibitive primer, fluoropolymer color coat, and clear fluoropolymer topcoat, with both color coat and clear topcoat containing not less than 70 percent polyvinylidene fluoride resin by weight, with a minimum total dry film thickness of 1.5 mil (0.038 mm); complying with physical properties and coating performance requirements of AAMA 2605, except as modified below:
a) Humidity Resistance: 1000hours.
b) Salt-Spray Resistance: 1000 hours.
Unless colors are preselected and specified or scheduled, retain one of three options in subparagraph below with finish selected above. Most manufacturers offer a variety of colors.
3) Color: As indicated by manufacturer's designations.
To obtain exact finish, insert names of coating manufacturers and products.
Insert concealed finish for roll-formed sheet metal roofing that is factory finished for interior surfaces.
2.3 MISCELLANEOUS MATERIALS
A. General: Provide materials and types of fasteners, solder, welding rods, protective coatings, separators, sealants, and other miscellaneous items as required for a complete roofing system and as recommended by fabricator for sheet metal roofing.
Delete first paragraph below if no batten-seam or horizontal-seam (Bermuda-type) sheet metal roofing or if battens are specified in Division 6 Section "Rough Carpentry."
B. Fasteners: Self-tapping screws, self-locking rivets and bolts, and other suitable fasteners designed to withstand design loads.
1. Exposed Fasteners: Heads matching color of sheet metal roofing by means of plastic caps or factory-applied coating.
2. Fasteners for Flashing and Trim: Blind fasteners or self-drilling screws with hex washer head.
3. Blind Fasteners: High-strength aluminum or stainless-steel rivets.
C. Sealing Tape: Pressure-sensitive, 100 percent solids, polyisobutylene compound sealing tape with release-paper backing. Provide permanently elastic, non-sag, nontoxic, non-staining tape.
Revise paragraph below if a sealant of a specific base polymer, type, grade, class, and use is required.
D. Elastomeric Joint Sealant: ASTM C 920, of base polymer, type, grade, class, and use classifications required to produce joints in sheet metal roofing that will remain weathertight and as recommended by roll-formed sheet metal roofing manufacturer for installation indicated.
Delete first paragraph below if no expansion joints.
E. Expansion-Joint Sealant: For hooked-type expansion joints, which must be free to move, provide nonsetting, nonhardening, nonmigrating, heavy-bodied polyisobutylene sealant.
2.4 ACCESSORIES
Revise first paragraph and subparagraphs below with specific requirements if necessary.
A. Sheet Metal Roofing Accessories: Provide components required for a complete sheet metal roofing assembly including trim, copings, fasciae, corner units, ridge cap or closures, clips, flashings, sealants, gaskets, fillers, closure strips, and similar items. Match material and finish of sheet metal roofing, unless otherwise indicated.
1. Closures: Provide closures at eaves and ridges, fabricated of same metal as sheet metal roofing.
Retain first subparagraph and associated subparagraphs below with custom-fabricated sheet metal roofing.
2. Cleats: Mechanically seamed cleats formed from 0.0250-inch- (0.65-mm-) thick, stainless-steel or nylon-coated aluminum sheet.
B. Flashing and Trim: Formed from 0.0179-inch- (0.45-mm-) thick, zinc-coated (galvanized) steel sheet or aluminum-zinc alloy-coated steel sheet prepainted with coil coating. Provide flashing and trim as required to seal against weather and to provide finished appearance. Locations include, but are not limited to, eaves, rakes, corners, bases, framed openings, ridges, fasciae, and fillers. Finish flashing and trim with same finish system as adjacent sheet metal roofing.
If required, insert special requirements for ridge closures, corner units, copings, fasciae, and fillers.
Snow guards are not provided by sheet metal roofing fabricators.
C. Snow Guards: Prefabricated, non-corrosive units designed to be installed without penetrating sheet metal roofing, and complete with predrilled holes, clamps, or hooks for anchoring.
Retain one of five guard types below. Because each snow-guard product is unique, insert manufacturer's proprietary requirements.
If acceptable, insert descriptions, manufacturers, and product names for snow-guard systems using fasteners that penetrate sheet metal roofing surface.
Pipe flashing below is not designed for high-temperature applications.
2.5 EQUIPMENT
A. Portable Roll-Forming Equipment: Manufacturer's standard UL-certified equipment capable of forming sheet metal roofing in profiles indicated.
Coordinate subparagraph and associated subparagraphs below with Part 2 "Manufacturers" Article. Retain "Available" for nonproprietary and delete for semiproprietary specifications.
2.6 FABRICATION
A. General: Custom fabricate sheet metal roofing to comply with details shown and recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to the design, dimensions (pan width and seam height), geometry, metal thickness, and other characteristics of installation indicated. Fabricate sheet metal roofing and accessories at the shop to greatest extent possible.
1. Standing-Seam Roofing: Form standing-seam pans with finished seam height of 1-1/2 inches (38 mm).
B. Fabricate sheet metal roofing to allow for expansion in running work sufficient to prevent leakage, damage, and deterioration of the Work. Form exposed sheet metal work to fit substrates without excessive oil canning, buckling, and tool marks, true to line and levels indicated, and with exposed edges folded back to form hems.
1. Lay out sheet metal roofing so cross seams, when required, are made in direction of flow with higher pans overlapping lower pans. Stagger cross seams.
2. Fold and cleat eaves and transverse seams in the shop.
3. Form and fabricate sheets, seams, strips, cleats, valleys, ridges, edge treatments, integral flashings, and other components of metal roofing to profiles, patterns, and drainage arrangements shown and as required for leakproof construction.
C. Expansion Provisions: Where lapped or bayonet-type expansion provisions in the Work cannot be used, form expansion joints of intermeshing hooked flanges, not less than 1 inch (25 mm) deep, filled with sealant (concealed within joints).
D. Sealant Joints: Where movable, non-expansion-type joints are indicated or required to produce weathertight seams, form metal to provide for proper installation of elastomeric sealant, in compliance with SMACNA standards.
E. Metal Protection: Where dissimilar metals will contact each other, protect against galvanic action by painting contact surfaces with bituminous coating, by applying rubberized-asphalt underlayment to each contact surface, or by other permanent separation as recommended by manufacturers of dissimilar metals or by fabricator.
Insert specific list of metals to be separated and protected for work as detailed.
F. Sheet Metal Accessories: Custom fabricate flashings and trim to comply with recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to design, dimensions, metal, and other characteristics of item indicated. Obtain field measurements for accurate fit before shop fabrication.
1. Form exposed sheet metal accessories that are without excessive oil canning, buckling, and tool marks and that are true to line and levels indicated, with exposed edges folded back to form hems.
2. Seams for Other Than Aluminum: Fabricate nonmoving seams in accessories with flat-lock seams. Tin edges to be seamed, form seams, and solder.
3. Sealed Joints: Form nonexpansion but movable joints in metal to accommodate elastomeric sealant to comply with SMACNA standards.
4. Conceal fasteners and expansion provisions where possible. Exposed fasteners are not allowed on faces of accessories exposed to view.
5. Fabricate cleats and attachment devices from same material as accessory being anchored or from compatible, noncorrosive metal.
a. Size: As recommended by SMACNA's "Architectural Sheet Metal Manual" for application but not less than thickness of metal being secured.
2.7 FINISHES, GENERAL
A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.
B. Protect mechanical and painted finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.
C. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, areas, and conditions, for compliance with requirements for installation tolerances, sheet metal roofing supports, and other conditions affecting performance of work.
1. Examine primary and secondary roof framing to verify that rafters, purlins, angles, channels, and other structural panel support members and anchorages have been installed.
Retain subparagraph above or first subparagraph below. Retain both if both conditions occur on Project.
2. Verify that substrate is sound, dry, smooth, clean, and completely anchored.
Delete subparagraph below if not required.
3. For the record, prepare written report, listing conditions detrimental to performance of work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Install flashings and other sheet metal to comply with requirements specified.
B. Install fasciae and copings to comply with requirements specified.
3.3 INSTALLATION, GENERAL
A. General: Install sheet metal roofing as indicated on plans. Anchor sheet metal roofing and other components of the Work securely in place, with provisions for thermal and structural movement. Install fasteners, protective coatings, separators, sealants, and other miscellaneous items as required for a complete roofing system and as recommended by fabricator for sheet metal roofing.
1. Field cutting of sheet metal roofing by torch is not permitted.
2. Rigidly fasten eave end of sheet metal roofing and allow ridge end free movement due to thermal expansion and contraction. Predrill roofing.
3. Provide metal closures at peaks, rake edges, rake walls, and each side of ridge and hip caps.
4. Flash and seal sheet metal roofing with weather closures at eaves, rakes, and at perimeter of all openings. Fasten with self-tapping screws.
5. Locate and space fastenings in uniform vertical and horizontal alignment.
B. Fasteners: Use fasteners of sizes that will not penetrate completely, but not more than ¼ inch past bottom surface of substrate.
1. Steel Roofing: Use stainless-steel fasteners.
C. Metal Protection: Where dissimilar metals will contact each other or corrosive substrates, protect against galvanic action by painting contact surfaces with bituminous coating, by applying rubberized-asphalt underlayment to each contact surface, or by other permanent separation as recommended by fabricator of sheet metal roofing or manufacturers of dissimilar metals.
D. Conceal fasteners and expansion provisions where possible in exposed work and locate to minimize possibility of leakage. Cover and seal fasteners and anchors as required for a tight installation.
E. Drip edge and Fascia: Align bottom of sheet metal roofing and fasten with blind rivets, bolts, or self-tapping screws. Flash and seal sheet metal roofing with weather closures along lower panel edges, and at perimeter of all openings.
3.4 CUSTOM-FABRICATED SHEET METAL ROOFING INSTALLATION
A. Fabricate and install work with lines and corners of exposed units true and accurate. Form exposed faces flat and free of buckles, excessive waves, and avoidable tool marks, considering temper and reflectivity of metal. Provide uniform, neat seams with minimum exposure of solder, welds, and sealant. Fold back sheet metal to form a hem on concealed side of exposed edges, unless otherwise indicated.
1. Install cleats to hold sheet metal panels in position. Attach each cleat with two fasteners to prevent rotation.
B. Seal joints as shown and as required for leakproof construction.
1. Where sealant-filled joints are used, embed hooked flanges of joint members not less than 1 inch (25 mm) into sealant. Form joints to completely conceal sealant. When ambient temperature at time of installation is moderate, between 40 and 70 deg F (4 and 21 deg C), set joint members for 50 percent movement either way. Adjust setting proportionately for installation at higher ambient temperatures. Do not install sealant-type joints at temperatures below 40 deg F (4 deg C).
C. Standing-Seam Roofing: Attach standing-seam metal pans to substrate with cleats, fastened at 12 inches (305 mm) o.c. Install pans reaching from eave to ridge before moving to adjacent pans. Lock each pan to pan below with transverse seam. Before pans are locked, apply continuous bead of sealant to top flange of lower pan. Crimp standing seams by folding over twice so cleat and pan edges are completely engaged.
Delete first subparagraph below for areas subject to ice dams. SMACNA recommends that sheet metal roofing be held back 24 inches (600 mm) from roof edge in these areas.
3.5 ACCESSORY INSTALLATION
Revise first paragraph and subparagraph below to suit Project. Delete items not required.
A. General: Install accessories with positive anchorage to building and weathertight mounting and provide for thermal expansion. Coordinate installation with flashings and other components.
1. Install components required for a complete sheet metal roofing assembly including trim, copings, ridge closures, seam covers, flashings, sealants, gaskets, fillers, closure strips, and similar items.
B. Flashing and Trim: Comply with performance requirements, manufacturer's written installation instructions, and SMACNA's "Architectural Sheet Metal Manual." Provide concealed fasteners where possible, and set units true to line and level as indicated. Install work with laps, joints, and seams that will be permanently watertight and weather resistant.
1. Install exposed flashing and trim that is without excessive oil canning, buckling, and tool marks and that is true to line and levels indicated, with exposed edges folded back to form hems. Install sheet metal flashing and trim to fit substrates and to result in waterproof and weather-resistant performance.
2. Expansion Provisions: Provide for thermal expansion of exposed flashing and trim. Space movement joints at a maximum of 10 feet (3 m) with no joints allowed within 24 inches (600 mm) of corner or intersection. Where lapped or bayonet-type expansion provisions cannot be used or would not be sufficiently weather resistant and waterproof, form expansion joints of intermeshing hooked flanges, not less than 1 inch (25 mm) deep, filled with mastic sealant (concealed within joints).
C. Stop-Type Snow Guards: Attach snow guards to sheet metal roofing with adhesive, sealant, or adhesive tape, as recommended by manufacturer. Do not use fasteners that will penetrate sheet metal roofing.
Delete last option in subparagraph below if standing-seam-mounted, stop-type snow guards are retained.
1. Provide 2 rows of snow guards, spaced 18 inches apart, beginning 12 inches up from edge, with each snow guard centered between sheet metal roofing ribs.
3.6 ERECTION TOLERANCES
Generally retain paragraph below only for sophisticated or highly finished sheet metal roofing assemblies.
A. Installation Tolerances: Shim and align sheet metal roofing within installed tolerance of 1/4 inch in 20 feet (6 mm in 6 m) on slope and location lines as indicated and within 1/8-inch (3-mm) offset of adjoining faces and of alignment of matching profiles.
If needed, insert installation tolerances from MCA's "Guide Specification for Residential Metal Roofing."
3.7 CLEANING AND PROTECTION
First paragraph below is not applicable to stainless steel and painted or coated steel and aluminum.
A. Clean exposed metal surfaces of substances that interfere with uniform oxidation and weathering.
B. Clean and neutralize flux materials. Clean off excess solder and sealants.
C. Remove temporary protective coverings and strippable films, if any, as sheet metal roofing is installed. On completion of sheet metal roofing installation, clean finished surfaces, including removing unused fasteners, metal filings, pop rivet stems, and pieces of flashing. Maintain in a clean condition during construction.
D. Replace panels that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures.
3.8 ROOFING INSTALLER'S WARRANTY
Delete this Article, retain this warranty, or include another roofing Installer's warranty form if required. Coordinate with Part 1 "Warranty" Article. Another sample layout of this warranty is included in the Evaluations.
A. WHEREAS <Insert name> of <Insert address>, herein called the "Roofing Installer," has performed roofing and associated work ("work") on the following project:
1. Owner: <Insert name of Owner.>
2. Address: <Insert address.>
3. Building Name/Type: <Insert information.>
4. Address: <Insert address.>
5. Area of Work: <Insert information.>
6. Acceptance Date: <Insert date.>
7. Warranty Period: <Insert time.>
8. Expiration Date: <Insert date.>
B. AND WHEREAS Roofing Installer has contracted (either directly with Owner or indirectly as a subcontractor) to warrant said work against leaks and faulty or defective materials and workmanship for designated Warranty Period, C. NOW THEREFORE Roofing Installer hereby warrants, subject to terms and conditions herein set forth, that during Warranty Period he will, at his own cost and expense, make or cause to be made such repairs to or replacements of said work as are necessary to correct faulty and defective work and as are necessary to maintain said work in a watertight condition.
D. This Warranty is made subject to the following terms and conditions:
1. Specifically excluded from this Warranty are damages to work and other parts of the building, and to building contents, caused by:
a. lightning;
Insert required wind speed below.
b. peak gust wind speed exceeding 120 mph;
c. fire;
d. failure of roofing system framing or substrate, including cracking, settlement, excessive deflection, deterioration, and decomposition;
e. vapor condensation on bottom of roofing; and
f. activity on roofing by others, including construction contractors, maintenance personnel, other persons, and animals, whether authorized or unauthorized by Owner.
2. When work has been damaged by any of foregoing causes, Warranty shall be null and void until such damage has been repaired by Roofing Installer and until cost and expense thereof have been paid by Owner or by another responsible party so designated.
3. Roofing Installer is responsible for damage to work covered by this Warranty but is not liable for consequential damages to building or building contents resulting from leaks or faults or defects of work.
4. During Warranty Period, if Owner allows alteration of work by anyone other than Roofing Installer, including cutting, patching, and maintenance in connection with penetrations, attachment of other work, and positioning of anything on roof, this Warranty shall become null and void on date of said alterations, but only to the extent said alterations affect work covered by this Warranty. If Owner engages Roofing Installer to perform said alterations, Warranty shall not become null and void unless Roofing Installer, before starting said work, shall have notified Owner in writing, showing reasonable cause for claim, that said alterations would likely damage or deteriorate work, thereby reasonably justifying a limitation or termination of this Warranty.
5. During Warranty Period, if original use of roof is changed and it becomes used for, but was not originally specified for, a promenade, work deck, spray-cooled surface, flooded basin, or other use or service more severe than originally specified, this Warranty shall become null and void on date of said change, but only to the extent said change affects work covered by this Warranty.
6. Owner shall promptly notify Roofing Installer of observed, known, or suspected leaks, defects, or deterioration and shall afford reasonable opportunity for Roofing Installer to inspect work and to examine evidence of such leaks, defects, or deterioration.
7. This Warranty is recognized to be the only warranty of Roofing Installer on said work and shall not operate to restrict or cut off Owner from other remedies and resources lawfully available to Owner in cases of roofing failure. Specifically, this Warranty shall not operate to relieve Roofing Installer of responsibility for performance of original work according to requirements of the Contract Documents, regardless of whether Contract was a contract directly with Owner or a subcontract with Owner's General Contractor.
E. IN WITNESS THEREOF, this instrument has been duly executed this <Insert day> day of <Insert month>, <Insert year>.
1. Authorized Signature: <Insert signature.>
2. Name: <Insert name.>
3. Title: <Insert title.>
END OF SECTION 07610
SHEET METAL ROOFING
SECTION 07610-3
File details come from the government source that posted it. Updated .