ROOM
CORRIDOR
ROOM
GREAT HALL
ROOM
PORCH
RESTROOM 2
RESTROOM 1
34'-9" 12'-2" 14'-11"
67'-8"
37'-0" 4'-3" 14'-2" 12'-3"
67'-8"
5'-10"
KEYNOTES
A. CAREFULLY SALVAGE & STORE ALL EXISTING
LIGHT FIXTURES. REMOVE ALL ABANDONED
WIRING FROM FIXTURES TO ELECTRIC PANEL.
COORDINATE W/ C.O.R..
A. EXISTING RADIATOR UNITS HAVE BEEN
ABANDONED. CONTRACTOR SHALL TAG AND
SALVAGE EXISTING GRILLEWORK TO BE
REUSED DURING THIS PROJECT.
A. REMOVE DOORS NO. 3 THROUGH NO. 9. FIELD
VERIFY OPENINGS TO PROVIDE A NEW 3'-0" X 6'-8"
OPENING TO RECEIVE NEW DOORS.
B. SALVAGE & STORE EXISTING DOORS, HINGES,
LATCH & LOCK SETS, LEVER HANDLES, ETC..
COORDINATE W/ C.O.R.
A. CAREFULLY SALVAGE AND STORE FOR REUSE
THE FOLLOWING:
WOOD T&G WALL AND CEILING PANELS,
WINDOW CASING AND TRIM, DOOR SURROUND
AND TRIM, BASEBOARD AND SHOE TRIM, AND
EXISTING DOOR HARDWARE.
A. REMOVE EXISTING IN-FLOOR RECEPTACLES, TO
BE REPLACED WITH GFCI RECEPTACLES. SEE
ELECTRICAL PLAN.
GENERAL NOTES
1. THIS BUILDING IS LISTED ON THE NATIONAL
REGISTER OF HISTORIC PLACES. THEREFORE,
THIS PROJECT IS SUBJECT TO SECTION 106 OF THE
NATIONAL HISTORIC PRESERVATION ACT. ALL
WORK SHALL CONFORM TO THE SECRETARY OF
THE INTERIOR'S STANDARDS FOR REHABILITATION.
2. SHADING ON PLAN DENOTES PROJECT
DEMOLITION/SALVAGE LIMITS. EXISTING ANIMAL
WASTE AND NESTING DEBRIS IN EXISTING WALLS
AND CEILINGS SHALL BE REMOVED.
3. THE HISTORIC CHARACTER OF THE PROPERTY
WILL BE RETAINED AND PRESERVED. THE
REMOVAL OF DISTINCTIVE MATERIALS OR
ALTERATION OF FEATURES, SPACES, AND SPATIAL
RELATIONSHIPS THAT CHARACTERIZE THE
PROPERTY WILL BE AVOIDED.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
CONSTRUCTING AND MAINTAINING ADEQUATE
TEMPORARY PROTECTION BARRIERS SUCH THAT
THE BUILDING REMAINS WEATHER TIGHT AND
SECURE.
5. ARCHAEOLOGICAL RESOURCES WILL BE
PROTECTED AND PRESERVED IN PLACE. PROTECT
ALL EXISTING WORK TO REMAIN FROM DAMAGE
DURING SELECTIVE REMOVAL AND NEW
CONSTRUCTION ACTIVITIES. IF SUCH RESOURCES
MUST BE DISTURBED, MITIGATION MEASURES WILL
BE UNDERTAKEN AND ALL PROTECTION SHALL BE
IN PLACE BEFORE ANY WORK COMMENCES.
6. SAW CUT ALL MATERIAL TO BE REMOVED FROM
MATERIALS TO REMAIN. AVOID ABRASION OR
DAMAGE OF FINISHED INTERIOR AND EXTERIOR
SURFACES AND MATERIALS THAT ARE TO REMAIN
BY TOOLS OR PROCESSES. REMOVE (TO
STRUCTURE) ALL MISCELLANEOUS MATERIALS,
METAL ANGLES, ANCHORS, HANGERS, BLOCKING,
SUPPORTS, DEVICES NO LONGER NEEDED.
7. THE CONTRACTOR SHALL COMPLY WITH LOCAL,
STATE AND FEDERAL RULES AND REGULATIONS
RELATED TO THE HANDLING, REMOVAL AND
DISPOSAL OF HAZARDOUS MATERIAL AND LEAD
BASED PAINT OR VARNISH.
8. PROTECT EXISTING FLOOR SURFACE AND SET-UP
TEMPORARY DUST BARRIER SEPARATION
PARTITIONS / DUST BARRIERS AT DOOR AND
WINDOW OPENINGS.
TRUE
NORTH
DEMOLITION/SALVAGE PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
A. REMOVE EXISTING SOUTH WALL OF CLOSET,
SHELVING, DOOR, SALVAGE. CONVERT CLOSET
TO HALL WAY. FLOOR TO MATCH ADJACENT
FLOOR, NORTH WALL TO BE T&G WOOD TO
MATCH EXISTING, EAST WALL TO BE GYPSUM
BOARD, WITH VINYL FLOOR BASE TO ADJACENT
WALL.
United States Department of Agriculture Forest Service
DATENO.
REVISION / ISSUE
1 00/00/00REVISION1
REVISION3
REVISION2
00/00/00
00/00/00
00/00/00REVISION4
A-01
Jun 28, 2017
D.DEAN
D.WILLEY
TST
DEMOLITION -
SALVAGE PLAN
GREAT DIVIDE DISTRICT OFFICE
CHEQUAMEGON-NICOLET
NATIONAL FOREST
FOREST LODGE
GUEST HOUSE
REHABILITATION
(R09) EASTERN REGION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
STAMPS, LOGOS, AND SEALS
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
ARCHIVE NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWING SHEET NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
CORRIDOR
ROOM
GREAT HALL
ROOM
PORCH
RESTROOM 2
RESTROOM 1
34'-9" 12'-2" 14'-11"
67'-8"
37'-0" 4'-3" 14'-2" 12'-3"
67'-8"
5'-10"
TRUE
NORTH
FLOOR PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEYNOTES
FOR WINDOW NUMBERS #1-10, AND DOOR NUMBERS
#03-09:
A. PROVIDE ADDITIONAL WOOD STUD FRAMING
MATERIAL TO STRENGTHEN/REPLACE EXISTING
WINDOWS AND WIDEN EXISTING DOOR
OPENINGS. ALL CONSTRUCTION/OPENINGS WILL
CONFORM TO IBC 2012.
B. FOR DOORS NO. 3 THROUGH NO. 9, FIELD
VERIFY OPENINGS TO PROVIDE AND INSTALL
NEW 3'-0" X 6'-8" X 1 3/4 INCH THICK - RAISED
PANEL WOOD DOORS FOR DOORS 3,6,7,8.
DOORS 4, 5, & 9 WILL BE REPLACED WITH
SIMILAR WOOD EXTERIOR DOORS. ALL DOORS
WILL BE ADA COMPLIANT HARDWARE INCLUDING
THRESHOLDS. ALL DOORS AND HARDWARE TO
BE SUBMITTED WITH CONTRACTOR PROPOSALS
FOR CO APPROVAL.
C. HINGES, LATCH & LOCK SETS, LEVER HANDLES,
ETC. TO MEET ADA/ABA COMPLIANCE AT ALL THE
DOORS.
FOR ROOM NUMBERS #102, 103, 104:
A. PROVIDE ADDITIONAL WOOD STUD FRAMING
MATERIAL TO STRENGTHEN/REPLACE EXISTING
WINDOWS AND WIDEN EXISTING DOOR
OPENINGS. ALL CONSTRUCTION/OPENINGS
WILL CONFORM TO IBC 2012.
B. INSTALL 3 INCHES OF CLOSED CELL SPRAY
FOAM AT EXTERIOR STUD WALLS AND EXISTING
CEILING CAVITIES. SHAVE AND SMOOTH ALL
WALL SURFACES.
C. REINSTALL THE SALVAGED, CLEANED, EXISTING
T&G BOARDS AT INTERIOR WALLS & CEILINGS,
BASEBOARDS AND WINDOW CASING, DOOR
TRIMS, ETC. ALL FINISHES TO MATCH EXISTING
PRIOR TO CONSTRUCTION.
D. EXISTING RADIATOR UNITS HAVE BEEN
ABANDONED. CONTRACTOR SHALL INSTALL 1/4"
PLYWOOD W/ INSULATION, PAINT BLACK, AND
LOCATE BEHIND EXISTING GRILLEWORK.
EXISTING GRILLEWORK TO BE REINSTALLED.
CO TO APPROVE METHODS OF CONSTRUCTION.
GENERAL NOTES
1. THIS BUILDING IS LISTED ON THE NATIONAL
REGISTER OF HISTORIC PLACES. THEREFORE,
THIS PROJECT IS SUBJECT TO SECTION 106 OF
THE NATIONAL HISTORIC PRESERVATION ACT.
ALL WORK SHALL CONFORM TO THE SECRETARY
OF THE INTERIOR'S STANDARDS FOR
REHABILITATION.
2. NEW ADDITIONS, EXTERIOR & INTERIOR
ALTERATIONS, OR RELATED NEW CONSTRUCTION
WILL NOT DESTROY HISTORIC MATERIALS,
FEATURES, AND SPATIAL RELATIONSHIPS THAT
CHARACTERIZE THE PROPERTY. THE NEW WORK
SHALL BE DIFFERENTIATED FROM THE OLD AND
WILL BE COMPATIBLE WITH THE HISTORIC
MATERIALS, FEATURES, SIZE, SCALE, AND
PROPORTION, AND MASSING TO PROTECT THE
INTEGRITY OF THE PROPERTY AND ITS
ENVIRONMENT.
3. THE CONTRACTOR SHALL VERIFY DESIGN AND
INSTALL ALL TEMPORARY SHORING AND SUPPORT
AS REQUIRED TO COMPLETE THE WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
CONSTRUCTING AND MAINTAINING ADEQUATE
TEMPORARY PROTECTION BARRIERS SUCH THAT
THE BUILDING REMAINS WEATHERTIGHT AND
SECURE.
5. CONTRACTORS SHALL COMPLY WITH GENERALLY
ACCEPTED STANDARDS AND ALL CODES AND
REGULATIONS. CONTRACTOR IS RESPONSIBLE
FOR THE COMPLETION OF THE END PRODUCT OF
WORK BY OTHERS UNDER HIS CONTRACT.
A. CONVERT CLOSET TO HALL WAY. FLOOR TO
MATCH ADJACENT FLOOR, NORTH WALL TO BE
T&G WOOD TO MATCH EXISTING, EAST WALL TO
BE GYPSUM BOARD, WITH VINYL FLOOR BASE
TO ADJACENT WALL.
A. NEW ADA RAMPS TO ACCESS THE BUILDING.
THE RAMPS WILL NEED TO MEET CURRENT
ABAAS STANDARDS, UNITED STATES ACCESS
BOARD. THE CONTRACTOR WILL SUBMIT A
SKETCH FOR FINAL CONSTRUCTION WHEN
SUBMITTING THE CONTRACTOR PROPOSAL.
SEE CIVIL SHEETS TO CONNECT RAMP TO MAIN
DRIVEWAY.
A. NEW ADA RAMP WILL NEED TO MAINTAIN
ACCESS TO GROUND BOX.
United States Department of Agriculture Forest Service
DATENO.
REVISION / ISSUE
1 00/00/00REVISION1
REVISION3
REVISION2
00/00/00
00/00/00
00/00/00REVISION4
A-02
June 28, 2017
D.DEAN
D.WILLEY
TST
FLOOR PLAN
GREAT DIVIDE DISTRICT OFFICE
CHEQUAMEGON-NICOLET
NATIONAL FOREST
FOREST LODGE
GUEST HOUSE
REHABILITATION
(R09) EASTERN REGION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
STAMPS, LOGOS, AND SEALS
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
ARCHIVE NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWING SHEET NO.
AutoCAD SHX Text
OF
CORRIDOR
ROOM
GREAT HALL
ROOM
PORCH
RESTROOM 2
RESTROOM 1
T
T
GENERAL NOTES
1. ALL OF THE MAIN FLOOR ROOMS - INCLUDING
THE GREAT HALL - WILL HAVE NEW CODE
COMPLIANT WIRING, CONDUIT, BOXES,
GROUNDED DUPLEX RECEPTICAL OUTLETS,
AND SWITCHES CONNECTED TO EXISTING
ELECTRIC PANEL WITH NEW CIRCUITS.
2. THE GREAT HALL SHALL GET TWO GROUNDED
DUPLEX RECEPTACLE FLOOR OUTLETS IN
FLUSH MOUNTED - FLOOR BOX (WITH WATER
PROOF SEAL & COVERS). LOCATE THESE
OUTLETS WHERE EXISTING OUTLETS WERE
REMOVED.
3. ALLOWANCE PER ROOM, FOR ALL EXISTING
WIRING BEING REMOVED FROM LOCATION
BACK TO PANEL (4 ROOMS PLANNED)
4. ALL ELECTRICAL FINISHES WILL MATCH THE
FINISHES IN THE HALLWAY ADJACENT TO FIRST
FLOOR BATHROOMS.
TRUE
NORTH
ELECTRICAL PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
EXISTING ELECTRIC SERVICE
PANEL IN BASEMENT
DUPLEX RECEPTACLE
CEILING LIGHT W/ PULL CHAIN
CEILING LIGHT FIXTURE
LEGEND
GROUND FAULT CIRCUIT
RECEPTACLE
TRIPLE-POLE SWITCH
SINGLE-POLE SWITCH
PC
PC
KEYNOTES
A. ALL NEW LIGHT FIXTURES WILL MATCH
EXISTING LIGHT FIXTURES IN THE HALLWAY BY
THE TWO FIRST FLOOR BATHROOMS.
A. THE ROOMS WILL ALL HAVE RECEPTACLES TO
MEET THE CURRENT NEC CODE. EACH ROOM
WILL ALSO HAVE A DOUBLE GANG BOX WITH
CONDUIT TO THE BASEMENT FOR FUTURE DATA
JACKS. ONE GANG BOX PER WALL. THE DATA
BOXES WILL HAVE BLANK COVERS WHEN
FINISHED.
A. THE GREAT ROOM WILL HAVE ALL THE
EXISTING WALL RECEPTACLES REPLACE
MEETING CURRENT NEC CODE. NO NEW
ADDITIONAL OUTLETS. WALL PLATE COVERS
TO MATCH EXISTING.
United States Department of Agriculture Forest Service
DATENO.
REVISION / ISSUE
1 00/00/00REVISION1
REVISION3
REVISION2
00/00/00
00/00/00
00/00/00REVISION4
E-01
June 28, 2017
D.DEAN
D.WILLEY
TST
ELECTRICAL
PLAN
GREAT DIVIDE DISTRICT OFFICE
CHEQUAMEGON-NICOLET
NATIONAL FOREST
FOREST LODGE
GUEST HOUSE
REHABILITATION
(RXX) REGION NAME
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
STAMPS, LOGOS, AND SEALS
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
ARCHIVE NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWING SHEET NO.
AutoCAD SHX Text
OF
34'-9" 12'-2" 14'-11"
67'-8"
37'-0" 4'-3" 14'-2" 12'-3"
67'-8"
5'-10"
KEYNOTES
GENERAL NOTES
1. THIS BUILDING IS LISTED ON THE NATIONAL
REGISTER OF HISTORIC PLACES. THEREFORE,
THIS PROJECT IS SUBJECT TO SECTION 106 OF
THE NATIONAL HISTORIC PRESERVATION ACT.
ALL WORK SHALL CONFORM TO THE SECRETARY
OF THE INTERIOR'S STANDARDS FOR
REHABILITATION.
2. NEW ADDITIONS, EXTERIOR & INTERIOR
ALTERATIONS, OR RELATED NEW CONSTRUCTION
WILL NOT DESTROY HISTORIC MATERIALS,
FEATURES, AND SPATIAL RELATIONSHIPS THAT
CHARACTERIZE THE PROPERTY. THE NEW WORK
SHALL BE DIFFERENTIATED FROM THE OLD AND
WILL BE COMPATIBLE WITH THE HISTORIC
MATERIALS, FEATURES, SIZE, SCALE, AND
PROPORTION, AND MASSING TO PROTECT THE
INTEGRITY OF THE PROPERTY AND ITS
ENVIRONMENT.
3. THE CONTRACTOR SHALL VERIFY DESIGN AND
INSTALL ALL TEMPORARY SHORING AND SUPPORT
AS REQUIRED TO COMPLETE THE WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
CONSTRUCTING AND MAINTAINING ADEQUATE
TEMPORARY PROTECTION BARRIERS SUCH THAT
THE BUILDING REMAINS WEATHERTIGHT AND
SECURE.
5. CONTRACTORS SHALL COMPLY WITH GENERALLY
ACCEPTED STANDARDS AND ALL CODES AND
REGULATIONS. CONTRACTOR IS RESPONSIBLE
FOR THE COMPLETION OF THE END PRODUCT OF
WORK BY OTHERS UNDER HIS CONTRACT.
TRUE
NORTH
BASEMENT PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
PROVIDE EATON METALUX AP SERIES, SLSTP
LENSED LED, 4SLSTP4040DD-120V OR
EQUIVALENT. PROVIDE CUT SHEET WITH
CONTRACTOR PROPOSAL.
United States Department of Agriculture Forest Service
DATENO.
REVISION / ISSUE
1 00/00/00REVISION1
REVISION3
REVISION2
00/00/00
00/00/00
00/00/00REVISION4
E-02
June 28, 2017
D.DEAN
D.WILLEY
TST
BASEMENT
LIGHTING PLAN
GREAT DIVIDE DISTRICT OFFICE
CHEQUAMEGON-NICOLET
NATIONAL FOREST
FOREST LODGE
GUEST HOUSE
REHABILITATION
(R09) EASTERN REGION
AutoCAD SHX Text
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
STAMPS, LOGOS, AND SEALS
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
ARCHIVE NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWING SHEET NO.
AutoCAD SHX Text
OF
| G-01 COVER SHEET_AccessPath G-01 COVER SHEET ACCESS PLAN (1) |
| C-01 SITE PLAN C-01 SITE PLAN (1) |
| A-01_Demolition-Salvage Plan-A-01 DEMO PLAN |
| Sheets and Views |
| A-01 DEMO PLAN |
| A-02_Floor Plan-A-02 FLOOR PLAN |
| Sheets and Views |
| A-02 FLOOR PLAN |
| E-01_Electrical Plan-E-01 ELECTRICAL PLAN |
| Sheets and Views |
| E-01 ELECTRICAL PLAN |
| E-02_Basement-Lighting-E-02 Basement |
| Sheets and Views |
| E-02 Basement |
| undefined: | |
| PROJECT LOCATION: | |
| IAXE ONTARIO: | |
| LI RlEfl LAKES I: | |
| undefined_2: | |
| VIRGIN V41: | |
| O Westwind Resort: | |
| undefined_3: | |
| Ga: | |
| undefined_4: | |
| DATECOVER SHEET: | |
| DATESITE PLAN: | |
| DATEDEMOLITIONSALVAGE PLAN: | |
| DATEFLOOR PLAN: | |
| DATEELECTRICAL PLAN: | |
| E02: | |
| DATEBASEMENT LIGHTING PLAN: | |
| 1: | |
| A301: | |
| undefined_5: | |
| SECTION NUMBER: | |
| undefined_6: | |
| undefined_7: | |
| undefined_8: | |
| WORK REQUIRED: | |
| 2017-08-23T16:20:22-0500 | |
| Mark Beuning |
| 2017-08-23T16:54:20-0500 | |
| MICHAEL MARTIN |
File details come from the government source that posted it. Updated .