About this file

Section 09 9000 - Painting Coating

View the file

Other files

File Type Posted
SF 30 Amendment 2.pdf PDF
Section 06 0110 Matinance of Rough Carpentry.doc DOC document
Franklin Lake Pre-bid Meeting Notes.doc DOC document
SF 30 Amendment 1.pdf PDF
Franklin Lake Specification 01 3000.doc DOC document
SF 1442 Cover Pg.pdf PDF
Specs Replacements Section 31 2200 Grading.pdf PDF
Franklin CG Vicinity Map 1.pdf PDF
SF 1442 Cont _0683.docx DOCX document
Franklin Lake Campground Drawings.pdf PDF
Experience Capability Statement 0683.doc DOC document
WI Vicinity Map 3.pdf PDF
Franklin CG Vicinity Map 2.pdf PDF
DBA.pdf PDF
Specifications.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Franklin Lake Campground Historic Building Restoration

CIM-0900-24F-32-0913-02

Historical Building Restoration

Construction

SECTION 09 9000

PAINTING AND COATING

PART 1 GENERAL

1.01

SECTION INCLUDES

A.

Surface preparation.

B.

Field application of paints, stains, and varnishes.

C.

Scope: Finish all interior and exterior surfaces exposed to view, unless fully factory-finished and unless otherwise indicated, including the following:

D.

Do Not Paint or Finish the Following Items:

1.

Items fully factory-finished unless specifically so indicated; materials and products having factory-applied primers are not considered factory finished.

2.

Items indicated to receive other finishes.

3.

Items indicated to remain unfinished.

4.

Fire rating labels, equipment serial number and capacity labels, and operating parts of equipment.

5.

Floors, unless specifically so indicated.

6.

Glass.

7.

Concealed pipes, ducts, and conduits.

1.02

RELATED REQUIREMENTS

A.

Section 01 6116 - Volatile Organic Compound (VOC) Content Restrictions.

1.03

REFERENCE STANDARDS

A.

40 CFR 59, Subpart D - National Volatile Organic Compound Emission Standards for Architectural Coatings; U.S. Environmental Protection Agency; current edition.

B.

ASTM D 4442 - Standard Test Methods for Direct Moisture Content Measurement of Wood and Wood-Base Materials; 2007.

C.

Secretary of the Interior's Standards for the Treatment of Historic Properties (36 CFR Part 68)

1.04

SUBMITTALS

A.

See Section 01 3000 - Administrative Requirements, for submittal procedures.

B.

Product Data: Provide data on all finishing products, including VOC content.

C.

Samples: Submit two paper chip samples, 3x3 inch in size illustrating range of colors available for each surface finishing product scheduled.

D.

Maintenance Materials: Furnish the following for USDA Forest Service's use in maintenance of project.

1.

See Section 01 6000 - Product Requirements, for additional provisions.

2.

Extra Paint and Coatings: 1 gallon of each color; store where directed.

3.

Label each container with color in addition to the manufacturer's label.

1.05

QUALITY ASSURANCE

A.

Manufacturer Qualifications: Company specializing in manufacturing the products specified, with minimum three years documented experience.

1.06

DELIVERY, STORAGE, AND HANDLING

A.

Deliver products to site in sealed and labeled containers; inspect to verify acceptability.

B.

Container Label: Include manufacturer's name, type of paint, brand name, lot number, brand code, coverage, surface preparation, drying time, cleanup requirements, color designation, and instructions for mixing and reducing.

C.

Paint Materials: Store at minimum ambient temperature of 45 degrees F and a maximum of 90 degrees F, in ventilated area, and as required by manufacturer's instructions.

1.07

FIELD CONDITIONS

A.

Do not apply materials when surface and ambient temperatures are outside the temperature ranges required by the paint product manufacturer.

B.

Follow manufacturer's recommended procedures for producing best results, including testing of substrates, moisture in substrates, and humidity and temperature limitations.

C.

Minimum Application Temperatures for Latex Paints: 45 degrees F for interiors; 50 degrees F for exterior; unless required otherwise by manufacturer's instructions.

D.

Minimum Application Temperature for Varnish Finishes: 65 degrees F for interior or exterior, unless required otherwise by manufacturer's instructions.

1.08

EXTRA MATERIALS

A.

See Section 01 6000 - Product Requirements, for additional provisions.

B.

Supply 1 gallon of each color; store where directed.

C.

Label each container with color in addition to the manufacturer's label.

PART 2 PRODUCTS

2.01

MANUFACTURERS

A.

Provide all paint and coating products used in any individual system from the same manufacturer; no exceptions.

B.

Paints:

1.

Comex Group (Color Wheel, Frazee, General Paint, Kwal, or Parker): www.thecomexgroup.com.

2.

Duron, Inc: www.duron.com.

3.

ICI Paints: www.icipaintsinna.com.

4.

Benjamin Moore & Co: www.benjaminmoore.com.

5.

PPG Architectural Finishes, Inc: www.ppgaf.com.

6.

Pratt & Lambert Paints: www.prattandlambert.com.

C.

Exterior Stains:

1.

Base Manufacturer: Sherwin Williams, www.sherwin-williams.com, Woodscape House Stain Exterior Acrylic Solid Color A15 Series.

D.

Substitutions: See Section 01 6000 - Product Requirements.

2.02

PAINTS AND COATINGS - GENERAL

A.

Paints and Coatings: Ready mixed, unless intended to be a field-catalyzed coating.

1.

Provide paints and coatings of a soft paste consistency, capable of being readily and uniformly dispersed to a homogeneous coating, with good flow and brushing properties, and capable of drying or curing free of streaks or sags.

2.

Supply each coating material in quantity required to complete entire project's work from a single production run.

3.

Do not reduce, thin, or dilute coatings or add materials to coatings unless such procedure is specifically described in manufacturer's product instructions.

B.

Primers: Where the manufacturer offers options on primers for a particular substrate, use primer categorized as "best" by the manufacturer.

C.

Volatile Organic Compound (VOC) Content:

1.

Provide coatings that comply with the most stringent requirements specified in the following:

a.

40 CFR 59, Subpart D--National Volatile Organic Compound Emission Standards for Architectural Coatings.

2.

Determination of VOC Content: Testing and calculation in accordance with 40 CFR 59, Subpart D (EPA Method 24), exclusive of colorants added to a tint base and water added at project site; or other method acceptable to authorities having jurisdiction.

D.

Exterior stain products shall comply with the Secretary of the Interior's Standards for the Treatment of Historic Properties (36 CFR Part 68).

E.

Exterior stain products shall comply be VOC compliant and EPA registered.

F.

Colors: As indicated in Color Schedule

1.

Allow for minimum of three colors for each system, unless otherwise indicated, without additional cost to USDA Forest Service.

2.03

PAINT & STAIN SYSTEMS - EXTERIOR

A.

Paint WE-OP-VS - Wood, Solid, Varnish, Stain:

1.

Two coats of stain.

2.04

PAINT SYSTEMS - INTERIOR

A.

Paint WI-TR-V - Wood, Transparent, Varnish, No Stain:

1.

One coat sealer.

2.

Gloss: Two coats of varnish; polyurethane for floor and wall applications.

B.

Paint WI-TR-VS - Wood, Transparent, Varnish, Stain:

1.

One coat of stain.

2.

Satin: Two coats of varnish.

C.

Paint GI-OP-3L - Gypsum Board/Plaster, Latex, 3 Coat:

1.

One coat of alkyd primer sealer.

2.

Semi-gloss: Two coats of latex enamel.

2.05

ACCESSORY MATERIALS

A.

Accessory Materials: Provide all primers, sealers, cleaning agents, cleaning cloths, sanding materials, and clean-up materials required to achieve the finishes specified whether specifically indicated or not; commercial quality.

B.

Patching Material: Latex filler.

C.

Fastener Head Cover Material: Latex filler.

PART 3 EXECUTION

3.01

EXAMINATION

A.

Verify that surfaces are ready to receive work as instructed by the product manufacturer.

B.

Examine surfaces scheduled to be finished prior to commencement of work. Report any condition that may potentially affect proper application.

C.

Test shop-applied primer for compatibility with subsequent cover materials.

D.

Measure moisture content of surfaces using an electronic moisture meter. Do not apply finishes unless moisture content of surfaces are below the following maximums:

1.

Gypsum Wallboard: 12 percent.

2.

Interior Wood: 15 percent, measured in accordance with ASTM D 4442.

3.

Exterior Wood: 15 percent, measured in accordance with ASTM D 4442.

3.02

PREPARATION

A.

Clean surfaces thoroughly and correct defects prior to coating application.

B.

Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

C.

Remove or mask surface appurtenances, including electrical plates, hardware, light fixture trim, escutcheons, and fittings, prior to preparing surfaces or finishing.

D.

Surfaces: Correct defects and clean surfaces which affect work of this section. Remove or repair existing coatings that exhibit surface defects.

E.

Seal surfaces that might cause bleed through or staining of topcoat.

F.

Remove mildew from impervious surfaces by scrubbing with solution of tetra-sodium phosphate and bleach. Rinse with clean water and allow surface to dry.

G.

Gypsum Board Surfaces to be Painted: Fill minor defects with filler compound. Spot prime defects after repair.

H.

Interior Log Wood Surfaces to Receive Opaque Finish: Wipe off dust and grit prior to priming. Seal knots, pitch streaks, and sappy sections with sealer. Fill nail holes and cracks after primer has dried; sand between coats. Back prime concealed surfaces before installation.

I.

Interior Wood Surfaces to Receive Transparent Finish: Wipe off dust and grit prior to sealing, seal knots, pitch streaks, and sappy sections with sealer. Fill nail holes and cracks after sealer has dried; sand lightly between coats. Prime concealed surfaces with gloss varnish reduced 25 percent with thinner.

J.

Exterior Log Wood to Receive Solid Finish: Remove dust, grit, and foreign matter; seal knots, pitch streaks, and sappy sections with sealer. Fill nail holes with tinted exterior calking compound after sealer has been applied. Prime concealed surfaces.

K.

Wood Doors to be Field-Finished: Seal wood door top and bottom edge surfaces with clear sealer.

3.03

APPLICATION

A.

Remove unfinished louvers, grilles, covers, and access panels on mechanical and electrical components and paint separately.

B.

Apply products in accordance with manufacturer's instructions.

C.

Do not apply finishes to surfaces that are not dry. Allow applied coats to dry before next coat is applied.

D.

Apply each coat to uniform appearance.

E.

Vacuum clean surfaces of loose particles. Use tack cloth to remove dust and particles just prior to applying next coat.

F.

Wood to Receive Transparent Finishes: Tint fillers to match wood. Work fillers into the grain before set. Wipe excess from surface.

G.

Reinstall electrical cover plates, hardware, light fixture trim, escutcheons, and fittings removed prior to finishing.

3.04

CLEANING

A.

Collect waste material that could constitute a fire hazard, place in closed metal containers, and remove daily from site.

3.05

PROTECTION

A.

Protect finished coatings until completion of project.

B.

Touch-up damaged coatings after Substantial Completion.

3.06

SCHEDULE - SURFACES TO BE FINISHED

A.

Do Not Paint or Finish the Following Items:

1.

Items fully factory-finished unless specifically noted.

2.

Fire rating labels, equipment serial number and capacity labels.

3.

Stainless steel items.

B.

Mechanical and Electrical: Use paint systems defined for the substrates to be finished.

1.

Paint all insulated and exposed pipes occurring in finished areas to match background surfaces, unless otherwise indicated.

C.

Paint both sides and edges of plywood backboards for electrical and telephone equipment before installing equipment.

3.07

SCHEDULE - PAINT SYSTEMS

A.

Interior Wood Paneling: WI-TR-VS: Color selected by Contract Officer

B.

Interior Gypsum Board: GI-OP-3L Color selected by owner from manufacturer's Standard Colors.

C.

All Exterior and Interior Log Finishes: WE-OP-VS, Color selected by Contract Officer

D.

Interior Trim: WI-TR-VS, Color to match existing, subject to Contract Officer Approval.

3.08

SCHEDULE - COLORS

A.

Picnic Shelter:

1.

Basement window infills; plywood panels - Sherwin Williams Ivory Ral 1014, #RHS8-40005.

END OF SECTION

PAINTING AND COATING

09 9000 - 5