amend_1.doc

DOC document 84 KB Posted

Attached to
Re-Roof Residence Buildings at Prospect RS
Solicitation number
AG-04N7-S-10-0021
Issued by

View the file

Other files

File Type Posted
06100 Plywood amendment 1.pdf PDF
07412 Roof Replacement amendment 1.pdf PDF
Return.doc DOC document
Specs.pdf PDF
Drawings.PDF PDF
ConstructionRfq..doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment 1 AG-04N7-S-09-0021 Rogue River-Siskiyou N.F.

Prospect R.S. Re-roofs Requisition #359696 Amendment No. 1 dtd 2/10/10

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
PAGE OF PAGES
2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
4. REQUISITION/PURCHASE REQ. NO.
5. PROJECT NO. (If applicable)
1
02-10-10
Req# 359696
6. ISSUED BY
CODE
7. ADMINISTERED BY (If other than Item 6)
CODE

USDA Forest Service

Rogue River-Siskiyou National Forest

3040 Biddle Road Medford, OR 97504-4119

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State, and ZIP Code)
(X)
9A. AMENDMENT OF SOLICITATION NO.
X
AG-04N7-S-10-0021

9B. DATED (SEE ITEM 11)

02-10-10

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

CODE
FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in item 14. The hour and date specified for receipt of Offers is extended, X is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If requird)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

(X)
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN

THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.

Reference Solicitation No. AG-04N7-S-10-0021 – Prospect R.S. Re-Roofs, High Cascades Ranger District, Rogue River-Siskiyou National Forest and amend as follows:

Part I – The Schedule – Section B – Schedule of Items – REMOVE (1 PAGE) AND REPLACE WITH ATTACHED SCHEDULE OF ITEMS (1 PAGE) – Solicitation Document and Return Document Section J – List of Attachments – Project Specifications – REMOVE SECTION 06100 PLYWOOD SHEATHING (1 PAGE) AND REPLACE WITH AMENDED 06100 (1 PAGE) (SEPARATE FILE); REMOVE SECTION 07412 – ROOF REPLACEMENT (4 PAGES) AND REPLACE WITH AMENDED SECTION 07412 – ROOF REPLACEMENT (5 PAGES) (SEPARATE FILE).

All else herein remains unchanged.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

MARGARET L. GIULIANI, Contracting Officer

15B. CONTRACTOR/OFFEROR
15C. DATE SIGNED
16B. UNITED STATES OF AMERICA
16C. DATE SIGNED
/s/ Margaret L. Giuliani
2/10/10

(Signature of person authorized to sign)

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

30-105
STANDARD FORM 30 (REV. 10-83)

Prescribed by GSFAR (48 C53.243

Reason for amendment:

· Schedule of Items - corrected DQ calculation errors in roof areas for building #1052, #1053, #1054, #1055:

Item 07412-1 was 21.75

Item 07412-2 was 21.75

Item 07412-3 was 21.75

Item 07412-4 was 21.75

Item 07412-5 was 20.5

Item 07412-6 was 20.5

Item 07412-7 was 20.5

Item 07412-8 was 20.5

· Specification wording clarifies only replacement of damaged roof sheathing, if found:

Section 06100 Plywood Sheathing - part 1.1, A.; part 3.1, A; and part 3.1, A, 1.

Section 07412 Roof Replacement - part 3.1, A., "Remove and dispose of all existing roof materials down to sheathing..."; and part 3.2, "DAMAGED ROOF SHEATHING"

Section 07412 Roof Replacement:

· Part 2.1, F., Roof pipe jacks, 2. Add - "Rubber boot material to be appropriate for use on hot or on cold stack application."

· Part 2.1., G., Add - "Ridge Vents", 1., "Continuous ridge vent of same material and by same manufacturer as metal roofing, and to include insect screening."

· Part 3.5, C., Add - "Bend down metal roof bottom edge per manufacturer's recommendations and tools to direct water into gutters."

· Part 3.6, A., Add - "Install new rubber boots on all roof jack penetrations."

· Part 3.6, B., Add - "Use heat-resistant material for contact with hot stack applications (i.e. building #1058 has two large diameter hot stacks, and two large diameter cool stacks)."

· Part 3.7, B., Add - "Install eave flashing trim into gutters."

· Part 3.7, C., should read: "Provide inverted “vee” type cricket flashing on all roof penetrations greater than 3 feet from roof ridgeline subject to damage from sliding snow loads."

· Part 3.7, E., Add - "Replace existing chimney crickets with new."

· Part 3.8, Add - "RIDGE VENTS", 1., "On roofs having existing individual square vents, replace with continuous insect-screened ridgeline venting."

All else remains unchanged.

PART I—THE SCHEDULE

SECTION B--SUPPLIES OR SERVICES AND PRICES/COSTS

SCHEDULE OF ITEMS

Prospect RS 6 Re-Roofs High Cascades Ranger District

Rogue River – Siskiyou National Forest

Jackson County, Oregon

ITEM NO
DESCRIPTION
METHOD OF MEASUREMENT
PAY UNIT
EST. QUANT.
UNIT PRICE
AMOUNT
01200-1
Mobilization
LSQ
LS
1
$_XXXXX_
$_________
06100-1
Plywood Sheathing,
AQ
SF
32
$_________
$_________
07412-1
Roof Removal,

Building 1052

DQ
SQ
23
$_________
$_________
07412-2
Roof Replacement,

Building 1052

DQ
SQ
23
$_________
$_________
07412-3
Roof Removal,

Building 1053

DQ
SQ
23
$_________
$_________
07412-4
Roof Replacement,

Building 1053

DQ
SQ
23
$_________
$_________
07412-5
Roof Removal,

Building 1054

DQ
SQ
22
$_________
$_________
07412-6
Roof Replacement,

Building 1054

DQ
SQ
22
$_________
$_________
07412-7
Roof Removal,

Building 1055

DQ
SQ
22
$_________
$_________
07412-8
Roof Replacement,

Building 1055

DQ
SQ
22
$_________
$_________
07412-9
Roof Removal,

Building 1058

DQ
SQ
21.75
$_________
$_________
07412-10
Roof Replacement,

Building 1058

DQ
SQ
21.75
$_________
$_________
07412-11
Roof Removal,

Building 1072

DQ
SQ
21.75
$_________
$_________
07412-12
Roof Replacement,

Building 1072

DQ
SQ
21.75
$_________
$_________
07412-13
Lower Rain gutters
LSQ
LS
1
$_XXXXX_
$_________

TOTAL QUOTE: $_______________

File details come from the government source that posted it. Updated .