f.BuildingElectricalPanelDirectories.pdf

PDF 95 KB Posted

Attached to
Sled Springs Power System Federal contract opportunity
Solicitation number
AG-04M3-S-16-0053
Issued by
Department of Agriculture Forest Service R6-Pacific Northwest Region

About this file

F. Building Electrical Panel Directories

View the file

Other files for this federal contract opportunity

Other files attached to Sled Springs Power System, newest first.
File Type Posted
Amendment02.docx DOCX document
Amendment01.docx DOCX document
d.Drawings.pdf PDF
h.FireProtectionandSuppressionr6_fS_6300_52.rtf RTF text file
c.Specifications.pdf PDF
a.offerors_packet.doc DOC document
b.final_solicitation.doc DOC document
g.wage_determination.txt TXT text file
e.BuildingEquipmentLoadLists.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

POLE WIRE C.B. LOAD LOAD C.B. WIRE POLE

NO. SIZE AMP/P TOTAL TYPE A B TYPE TOTAL AMP/P SIZE NO.

1A 14 20/1 Kitchen outlets 1000 A 2000 A 1000 Outlets and lights 15/1 14 2A

1B 14 20/1 Kitchen outlets 1000 A 2000 A 1000 Outlets and lights 15/1 14 2B

3A 14 20/1 Clothes washer 1000 A 2000 A 1000 Outlets and lights 15/1 14 4

3B 14 20/1 Bath Outlets 1000 A 2000 A 1000 Outlets and lights 15/1 14 6

5 14 20/1 Kitchen DC 1000 C 2000 A 1000 Outlets and lights 15/1 14 8

7 14 15/1 Dryer 1000 A 2000 A 1000 Refrigerator 15/1 14 10

9 14 15/1 Furnace 1000 B 2000 C 1000 Smoke detectors 15/1 14 12

11 14 15/1 Outlets and lights 1000 A 1000 C 14

13 C C 16

15 C C 18

17 C C 20

19 C C 22

21 C C 24

23 C C 26

25 C C 28

27 C C 30

29 C C 32

31 C C 34

33 C C 36

35 C C 38

37 C C 40

CONNECTED LOAD PER PHASE VA 8000 7000

CONNECTED LOAD PER PHASE A 67 58 Sled Springs Bunkhouse One

LOAD SUMMARY CONN. DEMAND DEMAND DATE: 6/5/2014

VA FACTOR VA VOLTS: 120/240V,1PH,3W PANEL

TYPE "A": RECEPTACLES (FIRST 10KVA) 10000.00 100% 10000.00 MAIN C.B.: 100A

TYPE "A": RECEPTACLES (OVER 10KVA) 2000.00 50% 1000.00 BUS: 100 AMP A

TYPE "B": NON-CONTINUOUS LOADS 1000.00 100% 1000.00 POLES: 12

TYPE "C": CONTINUOUS LOADS 2000 125% 2500 MOUNTING: Recessed

TOTAL DEMAND LOAD VA 15000 14500 AIC RATING:

TOTAL DEMAND LOAD AMPS 60 SUBFEED C.B: NA

REV 8/30/07

Enter data in non green areas only

MINIMUM SERVICE SIZE 75.52 AMPS

LOCATION:

LOAD VA

1 14 20/1 Kitchen outlets 1000 A 2000 A 1000 Bathroom 20/1 14 2

3 14 20/1 Kitchen outlets 1000 A 2000 B 1000 Furnace 15/1 14 4

5A 14 20/1 Clothes washer 1000 A 2000 A 1000 Bedroom 15/1 14 6

5B 14 20/1 Dosing tank pump 1000 B 2000 A 1000 Bedroom 15/1 14 8

7 14 20/1 Kitchen DC 1000 C 2000 A 1000 Dryer 15/1 14 10A

9 14 15/1 Range 1000 A 2000 A 1000 Refrigerator 15/1 14 10B

11A 14 15/1 Range 1000 A 2000 C 1000 Smoke detectors 15/1 14 12A

11B 14 15/1 Bedroom 1000 A 2000 A 1000 Bedroom 15/1 14 12B

13 C C 14

15 C C 16

17 C C 18

19 C C 20

21 C C 22

23 C C 24

25 C C 26

27 C C 28

29 C C 30

31 C C 32

33 C C 34

35 C C 36

37 C C 38

CONNECTED LOAD PER PHASE VA 8000 8000

CONNECTED LOAD PER PHASE A 67 67 Sled Springs Bunkhouse Two

LOAD SUMMARY CONN. DEMAND DEMAND DATE: 6/5/2014

VA FACTOR VA VOLTS: 120/240V,1PH,3W PANEL

TYPE "A": RECEPTACLES (FIRST 10KVA) 10000.00 100% 10000.00 MAIN C.B.: 100A

TYPE "A": RECEPTACLES (OVER 10KVA) 2000.00 50% 1000.00 BUS: 100 AMP A

TYPE "B": NON-CONTINUOUS LOADS 2000.00 100% 2000.00 POLES: 12

TYPE "C": CONTINUOUS LOADS 2000 125% 2500 MOUNTING: Recessed

TOTAL DEMAND LOAD VA 16000 15500 AIC RATING:

TOTAL DEMAND LOAD AMPS 65 SUBFEED C.B: NA

REV 8/30/07

Enter data in non green areas only

MINIMUM SERVICE SIZE 80.73 AMPS

1 12 20/1 Meeting Room and Exterior Lights 1000 C 2000 C 1000 Bed, Bath, Storage, Kitchen Lights 20/1 12 2

3 12 20/1 Meeting Room Outlets 1000 C 2000 C 1000 Kitchen Outlets 20/1 12 4

5 12 20/1 Kitchen Outlets 1000 C 2000 C 1000 Bed, Bath Outlets 20/1 12 6

7 12 20/1 Range Hood 1000 C 2000 C 1000 Not Used? 20/1 12 8

9 12 20/1 Spare 1000 C 2000 C 1000 Spare 20/1 12 10

11 10 30/1 Not Used C 1000 C 1000 Spare 20/1 12 12

13 10 Not Used C 1000 C 1000 Spare 20/1 12 14

15 -- -- Blank C C Blank -- -- 16

17 -- -- Blank C C Blank -- -- 18

19 C C 20

21 C C 22

23 C C 24

25 C C 26

27 C C 28

29 C C 30

31 C C 32

33 C C 34

35 C C 36

37 C C 38

39 C C 40

41 C C 42

CONNECTED LOAD PER PHASE VA 7000 5000

CONNECTED LOAD PER PHASE A 58 42 Sled Springs Mess Hall

LOAD SUMMARY CONN. DEMAND DEMAND DATE: 6/5/2014

VA FACTOR VA VOLTS: 120/240V,1PH,3W PANEL

TYPE "A": RECEPTACLES (FIRST 10KVA) 100% MAIN C.B.: 100A

TYPE "A": RECEPTACLES (OVER 10KVA) 50% BUS: 100 AMP A

TYPE "B": NON-CONTINUOUS LOADS 100% POLES: 18

TYPE "C": CONTINUOUS LOADS 12000 125% 15000 MOUNTING: Recessed

TOTAL DEMAND LOAD VA 12000 15000 AIC RATING: 22,000

TOTAL DEMAND LOAD AMPS 63 SUBFEED C.B: NA

REV 8/30/07

Enter data in non green areas only

MINIMUM SERVICE SIZE 78.13 AMPS

1 100 Main C 1000 A 1000 Outlets and lights 20/1 12 2

3 Main C 1000 A 1000 Outlets and lights 20/1 12 4

5 Blank C 1000 A 1000 Outlets and lights 20/1 12 6

7 Blank C 1000 A 1000 Outlets and lights 20/1 12 8

9 Blank C 1000 A 1000 Outlets and lights 20/1 12 10

11 Blank C 1000 A 1000 Outlets and lights 20/1 12 12

13 Blank C C Blank 14

15 Blank C C Blank 16

17 Blank C C Blank 18

19 Blank C C Blank 20

21 C C 22

23 C C 24

25 C C 26

27 C C 28

29 C C 30

31 C C 32

33 C C 34

35 C C 36

37 C C 38

39 C C 40

41 C C 42

CONNECTED LOAD PER PHASE VA 3000 3000

CONNECTED LOAD PER PHASE A 25 25 Sled Springs Old Bunkhouse

LOAD SUMMARY CONN. DEMAND DEMAND DATE: 6/5/2014

VA FACTOR VA VOLTS: 120/240V,1PH,3W PANEL

TYPE "A": RECEPTACLES (FIRST 10KVA) 6000.00 100% 6000.00 MAIN C.B.: 100A

TYPE "A": RECEPTACLES (OVER 10KVA) 50% BUS: 100 AMP A

TYPE "B": NON-CONTINUOUS LOADS 100% POLES: 20

TYPE "C": CONTINUOUS LOADS 125% MOUNTING: Recessed

TOTAL DEMAND LOAD VA 6000 6000 AIC RATING:

TOTAL DEMAND LOAD AMPS 25 SUBFEED C.B: NA

REV 8/30/07

Enter data in non green areas only

MINIMUM SERVICE SIZE 31.25 AMPS

1 12 20/1 Main Lights 1000 A 2000 A 1000 Outlets 20/1 12 2

3 Blank C C Blank 4

5 Blank C C Blank 6

7 Blank C C Blank 8

9 Blank C C Blank 10

11 Blank C C Blank 12

13 Blank C C Blank 14

15 Blank C C Blank 16

17 Blank C C Blank 18

19 Blank C C Blank 20

21 C C 22

23 C C 24

25 C C 26

27 C C 28

29 C C 30

31 C C 32

33 C C 34

35 C C 36

37 C C 38

39 C C 40

41 C C 42

CONNECTED LOAD PER PHASE VA 2000

CONNECTED LOAD PER PHASE A 17 Sled Springs PT Room

LOAD SUMMARY CONN. DEMAND DEMAND DATE: 6/5/2014

VA FACTOR VA VOLTS: 120/240V,1PH,3W PANEL

TYPE "A": RECEPTACLES (FIRST 10KVA) 2000.00 100% 2000.00 MAIN C.B.: 100A

TYPE "A": RECEPTACLES (OVER 10KVA) 50% BUS: 100 AMP A

TYPE "B": NON-CONTINUOUS LOADS 100% POLES: 20

TYPE "C": CONTINUOUS LOADS 125% MOUNTING: Surface

TOTAL DEMAND LOAD VA 2000 2000 AIC RATING:

TOTAL DEMAND LOAD AMPS 8 SUBFEED C.B: NA

REV 8/30/07

Enter data in non green areas only

MINIMUM SERVICE SIZE 10.42 AMPS

1 12 20/1 Main Lights 1000 C 2000 A 1000 Office 2 Outlets 20/1 12 2

3 12 20/1 Office 1 Outlets 1000 A 2000 A 1000 Office 1 Outlets 20/1 12 4

5 12 20/1 Office 1 Outlets 1000 A 2000 A 1000 East Wall Shop Outlets 20/1 12 6

7 20/1 Spare 1000 A 2000 A 1000 North Wall Shop Outlets 20/1 12 8

9 Blank C C Blank 10

11 Blank C C Blank 12

13 Blank C C Blank 14

15 Blank C C Blank 16

17 Blank C C Blank 18

19 Blank C C Blank 20

21 C C 22

23 C C 24

25 C C 26

27 C C 28

29 C C 30

31 C C 32

33 C C 34

35 C C 36

37 C C 38

39 C C 40

41 C C 42

CONNECTED LOAD PER PHASE VA 4000 4000

CONNECTED LOAD PER PHASE A 33 33 Sled Springs Warehouse

LOAD SUMMARY CONN. DEMAND DEMAND DATE: 6/5/2014

VA FACTOR VA VOLTS: 120/240V,1PH,3W PANEL

TYPE "A": RECEPTACLES (FIRST 10KVA) 7000.00 100% 7000.00 MAIN C.B.: 100A

TYPE "A": RECEPTACLES (OVER 10KVA) 50% BUS: 100 AMP A

TYPE "B": NON-CONTINUOUS LOADS 100% POLES: 20

TYPE "C": CONTINUOUS LOADS 1000 125% 1250 MOUNTING: Recessed

TOTAL DEMAND LOAD VA 8000 8250 AIC RATING: 22,000

TOTAL DEMAND LOAD AMPS 34 SUBFEED C.B: NA

REV 8/30/07

Enter data in non green areas only

MINIMUM SERVICE SIZE 42.97 AMPS

BunkhouseOneMasterPanel
BunkhouseTwoMasterPanel
MessHallMasterPanel
OldBunkhouseMasterPanel
PTRoomMasterPanel
WarehouseMasterPanel