FIRE CLAUSE
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Drawings_ SnowCreek20091029.pdf | ||
| sf25_e.pdf | ||
| MOU-Jan25_signed.pdf | ||
| WA120_dvb.txt | TXT text file | |
| Fire Plan.doc | DOC document | |
| sf24_e.pdf | ||
| sf25a_e.pdf | ||
| WA1_dvb.txt | TXT text file | |
| SOW_Specs_ Snow_Creek.doc | DOC document | |
| WA88_dvb.txt | TXT text file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H.XX Industrial Fire Precaution Levels
The Contractor shall comply with the operations restrictions in accordance with the Washington State Industrial Fire Precaution Level (IFPL) system. The IFPL system is used to help prevent wildfires by regulating work in the woods during the summer fire season.
The US Forest Service and the Washington DNR use the four-level industrial regulation system.
The Precaution Levels are:
| Level I |
| Closed Fire Season |
| Fire equipment and fire watch service is required. |
| Level II |
| Partial Hoot Owl |
| Limits certain activities to between the hours of 8 p.m. and 1 p.m. |
| Level III |
| Partial Shutdown |
| Prohibits some activities altogether and limits other activities to between the hours of 8 p.m. and 1 p.m. |
| Level IV |
| General Shutdown |
| All operations prohibited |
Operation: Power Saws
| Precaution Level |
| Landing |
| Tractor/Skidder |
| Other Woods Saws |
| I. Closed Season |
| Fire Watch |
| Fire Watch |
| Fire Watch |
| II. Partial Hoot Owl |
| Fire Watch |
| Hoot Owl |
| Hoot Owl |
| III. Partial Shutdown |
| Hoot Owl |
| Hoot Owl |
| Prohibited |
| IV. General Shutdown |
| Prohibited |
| Prohibited |
| Prohibited |
Other Operations
| Precaution Level |
| Loading |
| Blasting |
| Welding |
| I. Closed Season |
| Fire Watch |
| Fire Watch |
| Fire Watch |
| II. Partial Hoot Owl |
| Fire Watch |
| Hoot Owl |
| Hoot Owl |
| III. Partial Shutdown |
| Hoot Owl |
| Hoot Owl |
| Hoot Owl |
| IV. General Shutdown |
| Prohibited |
| Prohibited |
| Prohibited |
This project is located in one of the following zones:
652NE
Northern portion of the Hood Canal RD
652SE
Southern portion of the Hood Canal RD
652NW
Northern portion of the Pacific RD
652SW
Southern portion of the Pacific RD
The Fire Precaution Class can be found at: http://www2.wadnr.gov/IFPL/ifpltoday.html or by calling 1-800-527-3305.