Attachment 3 Solicitation No.: AG-0261-S-16-0043

W.H.

M

W.H.

M

J

JJ

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

EXISTING METERMAIN TO REMAIN WITH SERVICE,

FEEDER, AND GROUNDING

EXISTING LOAD CENTER/ PANELBOARD TO REMAIN

WITH BREAKERS AND SOME LOADS, SEE PANEL A

SCHEDULE AND NOTES

EXISTING TELECOMMUNICATIONS JUNCTION BOX TO

REMAIN

REMOVE FLUSH MOUNTED LOAD CENTER/

PANELBOARD, REPAIR WALL EXCEPT PANELING

REPAIR OR REPLACEMENT AT THIS LOCATION BY

OTHERS WHICH MAY OCCUR DURING OR AFTER THIS

CONTRACT

SAFETY SWITCH TO REMAIN, SEE FURNACE PHOTO

JUNCTION BOX TO REMAIN AND BE REUSED

REMOVE BUZZER AND RELATED EQUIPMENT

REMOVE SMOKE ALARM

SPEAKER TO REMAIN, INCLUDING ALL RELATED

CABLING FROM THE BUILDING NEXT DOOR

EXHAUST FAN/LIGHT COMBINATION, REPAIR CEILING

TO FIT NEW EXHAUST FAN

EXISTING SURFACE MOUNTED FLUORESCENT

LUMINAIRE TO REMAIN

EXISTNG LUMINAIRE TO REMAIN: SURFACE AND

WALL MOUNT

REMOVE AND SALVAGE FOR REUSE, SURFACE

MOUNTED FLUORESCENT LUMINAIRE

REMOVE LUMINAIRE: SURFACE AND WALL MOUNT

REMOVE SWITCH

REMOVE RECEPTACLE

REMOVE DATA OUTLET, 2 OR MORE PORTS

REMOVE TELEPHONE OUTLET

ELECTRIC WATER HEATER, 120 VAC, 1.5KW, CORD

AND PLUG CONNECTED, TO REMAIN

INTAKE VENT TO REMAIN

EXHAUST VENT TO REMAIN

WALL CONSTRUCTION: WOOD SLATS, WIRE AND

PLASTER OVER STUDS, MAY ALSO HAVE GLUED ON

PANELING

WALL CONSTRUCTION: VARIES, PLASTER,

SHEETROCK, PANELING OR A COMBINATION OVER

BRICK, OFTEN GLUED

WALL CONSTRUCTION: SHEETROCK OVER STUDS,

MAY ALSO HAVE GLUED ON PANELING

S

P

EXISTING DEVICE BOX EMBEDDED IN THE BRICK TO

REMAIN, TO BE REWIRED AND NEW LUMINAIRE

INSTALLED

REMOVE SURFACE MOUNTED CONDUIT OR

WIREMOLD AND REPAIR MOUNTING HOLES IN BRICK,

PANELING, OR, PLASTER AND SHEETROCK FINISHES

REMOVE SURFACE MOUNTED CONDUIT OR

WIREMOLD GOING UP WALL FROM REMOVED DEVICE

AND REPAIR MOUNTING HOLES IN BRICK, PANELING,

OR, PLASTER AND SHEETROCK FINISHES

SWITCH IS SURFACE MOUNTED LOW ON WALL IN

WIREMOLD THAT FEEDS RECEPTACLES BEING

REMOVED

KEYED FIXTURE WITH SWITCH AND RECEPTACLE

BELOW (2 GANG BOX, SURFACE MOUNT FED FROM

ABOVE IN MC CABLE TO BE REMOVED

BATH FAN WITH BUILT IN LIGHT TO BE REMOVED,

CEILING TO BE REPAIRED TO FIT REPLACEMENT FAN,

THE SEPARATE LIGHT TO REMAIN SHALL HAVE A

NEW 6-INCH ROUND FROSTED, UV-STABILIZED

ACRYLIC OR LEXAN GLOBE INSTALLED

TWO RECEPTACLES IN A DOUBLE GANG RECESSED

BOX, BOX CANNOT BE REUSED AS HEIGHT DOES NOT

MEET ACCESSIBILITY STANDARDS.

REMOVE TIMER SWITCH IN THE SAME BOX FOR THE

PORCH LUMINAIRE

REMOVE RECESSED LOAD CENTER, BRANCH

CIRCUITS AND FEEDER, WOOD PANELING

REPLACEMENT BY OTHERS AND MAY NOT HAPPEN

DURING CONTRACT

FURNACE WIRING AND DISCONNECT TO REMAIN,

REPLACE CIRCUIT, SEE PHOTO

AC CONDENSING UNIT TO REMAIN WITH LOW

VOLTAGE CONTROL LINES, LINE VOLTAGE LINES

SHALL BE REMOVED AND REPLACED, SEE PHOTO

EXISTING ATTIC ACCESS, SIZE IS NOT SHOWN

CORRECTLY ON DRAWINGS, THE SMALLEST IS

21"x12" WHILE THE LARGEST IS 25"x12.75", IT IS

ALLOWED TO REMAKE ANY ACCESS LARGER

TWO RECEPTACLES IN A DOUBLE GANG BOX,

CONDUIT AND BOX MAY REMAIN FOR REUSE

THERMOSTAT AND LOW VOLTAGE WIRE TO FURNACE

AND AC UNIT TO REMAIN

CONDUIT TO REMAIN, REWORK BUILDING ENTRY

LOCATION, SEE PHOTO

SPEAKER AND RELATED WIRING TO REMAIN, FED

FROM OTHER BUILDING

INDICATES ENTIRE ROOM OR HALL HAS PANELING

ON THE WALLS, IF WITH AN ARROW POINTING TO A

WALL THEN JUST THAT WALL IS PANELED

EXPOSED DAMAGED CEILING TILE TO BE REPAIRED

BY OTHERS

S

P

S

NOTE: REWORK THE GROUNDING ELECTRODE CONDUCTOR (GEC)

TO THE INTERIOR METAL WATER SERVICE (LIKELY PROVIDED

NOW THROUGH THE INTERIOR PANEL TO BE REMOVED). THE GEC

SHALL BE ROUTED TO ENTER BUILDING NEAR AC CONDENSER

CONDUIT TO PROVIDE PROTECTION AND HIDE THE CONDUCTOR.

BUZZER WITH COVER

OFF

REPLACE GLOBE PER

NOTES

SPACE FOR FUTURE

UPS

COMMUNICATIONS GENERAL NOTES

1. DATA AND VOICE HORIZONTAL CABLING AND OUTLETS SHALL ALL BE REMOVED. DATA FIBER

OPTIC AND VOICE BACKBONE CABLES SHALL REMAIN INCLUDING CONNECTIONS.

2. SEE SPECIFICATIONS FOR NEW REQUIREMENTS, INCLUDING GROUNDING AS NOTED IN SECTION

270526.

3. DOCUMENT THE EXISTING PATCH PANEL PHONE OR VOICE CONNECTION SETUP TO HELP THE

FOREST SERVICE IN RECONNECTING PHONE LINES. TO PROPER LOCATIONS. THIS PATCH PANEL

WILL SERVE AS CONNECTION TO EXISTING PHONE OR VOICE BACKBONE ONLY.

DOCUMENTATION MAY BE ON BUILDING FLOOR PLAN OR SIMPLY NOTING LEGIBLY (HAND

WRITING ALLOWED) ON 8.1x11 SHEETS OF PAPER FOR EACH PATCH PANEL PORT.

3.1. INDICATE IF PORT USED OR UNUSED. IF UNUSED NO OTHER DOCUMENTATION NEEDED.

3.2. INDICATE IF PORT IS VOICE OR DATA. IF DATA, NO OTHER DOCUMENTATION REMOVE

CONNECTION.

3.3. INDICATE THE ROOM NUMBER SERVED (SEE RECEPTACLE PLAN FOR ROOM NUMBERS) AND

WHICH WALL THE WORK AREA PORT WAS ON (NORTH, SOUTH, EAST, OR WEST) . IF TWO

WORK AREA VOICE PORTS ARE ON THE SAME WALL, ADD A SECOND DIRECTION SUCH AS:

PORT 24-USED-VOICE-ROOM 15-NORTH WALL-EAST OUTLET.

3.4. DOCUMENT EVERY PATCH CABLES PORT-TO-PORT CONNECTION SUCH AS: PATCH CABLE

PORT 24 TO HUB 5, OR PATCH CABLE PORT 7 TO PORT 29.

3.5. WHERE THE PORT IS DIRECTLY CONNECTED TO THE PUNCH DOWN BLOCKS, DETERMINE

AND PERMANENTLY RECORD THE 4 DIGIT EXTENSION DIRECTLY ON THE PATCH PANEL

ABOVE THE PORT.

3.6. PROVIDE 2 COPIES OF THE DOCUMENTATION TEMPORARILY MOUNTED TO WALL IN

COMMUNICATIONS CLOSET AND A 3RD COPY PROVIDED TO THE CONTRACTING OFFICER.

4. PRESERVE ALL COMMUNICATIONS WIRING FROM PATCH PANEL TO THE PUNCH DOWN BLOCKS

AND ALL COMMUNICATIONS WIRING COMING INTO THE BUILDING AND LANDING IN LIU OR PUNCH

DOWN BLOCKS. IF ANY EXTERNAL WIRING TERMINATES DIRECTLY IN THE PATCH PANEL, IT

SHALL REMAIN.

5. AFTER DOCUMENTATION, SALVAGE ALL PATCH CORDS FOR REUSE BY OTHERS. FIBER OPTIC

PATCH CORD FORM THE LIU TO THE HUB SHALL REMAIN CONNECTED.

6. AFTER DOCUMENTATION, REMOVE ALL INTERIOR WIRING FROM PATCH PANEL TO WORK AREA

OUTLETS.

7. REARRANGE EQUIPMENT ADDING NEW EQUIPMENT AS CALLED FOR. CONNECT NEW WORK

AREA OUTLETS AND DOCUMENT AS PER SPECIFICATIONS LEAVING EXCESS CABLE BEHIND OR

TO THE SIDES OF THE RACK IN A VERTICAL CABLE MANAGER.

8. PROVIDE ADDITIONAL PATCH CABLES PER SPECIFICATIONS.

9. FINAL PATCHING/ACTIVATING PORTS AND ADDING PHONE LINES SHALL BE DONE BY OTHERS.

EXISTING METERMAIN TO REMAIN WITH SERVICE,

FEEDER, AND GROUNDING

EXISTING LOAD CENTER/ PANELBOARD TO REMAIN

WITH BREAKERS AND SOME LOADS, SEE PANEL A

SCHEDULE AND NOTES

EXISTING TELECOMMUNICATIONS JUNCTION BOX TO

REMAIN

SAFETY SWITCH TO REMAIN, SEE FURNACE PHOTO

NON-METALLIC SURFACE RACEWAY, PANDUIT

PAN-WAY T-45 SERIES WITH DIVIDER (INSTALL

COMMUNICATIONS IN LARGER CHANNEL)

INDICATES CONNECTION INTO WALL FOR

CONCEALED CIRCUIT FEED WHERE HOLLOW WALL

INDICATED, SOLID WALLS SHALL HAVE SURFACE

RACEWAY FEEDS FROM CEILING, AND IN ROOM 1

WEST WALL FEED SHALL BE CONCEALED IN THE

CABINET, SEE INSTALLATION NOTES

FAN - CEILING, OF TYPE SPECIFIED (SEE LIGHT

SCHEDULE)

SPEAKER TO REMAIN, INCLUDING ALL RELATED

CABLING FROM THE BUILDING NEXT DOOR

SMOKE ALARM, KIDDE I12040

CARBON MONOXIDE/SMOKE COMBINATION ALARM,

KIDDE KN-COSM-IBA

SALVAGED FLUORESCENT LUMINAIRE, TYPE "X":

SURFACE MOUNT

EXISTING FLUORESCENT LUMINAIRE TO REMAIN,

REWIRE

LUMINAIRE, TYPE "X": SURFACE AND WALL MOUNT

LUMINAIRE TO REMAIN: SURFACE AND WALL MOUNT

PIR OCCUPANCY SENSOR, CEILING MOUNTED, LINE

VOLTAGE, SMALL MOTION DETECTION, SET FOR 20

MINUTES AND WALK THROUGH, EXCEPT FOR HALL

SET FOR WALK THROUGH ONLY, AND BATHROOM

SET FOR 5 MINUTES AND WALKTHROUGH

PHOTO CONTROL, 120 VAC, WITH ADJUSTABLE

SHUTTER, WEATHER RESISTANT

SINGLE POLE

RECEPTACLE, DUPLEX

RECEPTACLE, DUPLEX OR TYPE SHOWN MOUNT

ABOVE COUNTER TOP FOR COUNTER ACCESS

RECEPTACLE, GFCI PROTECTION PROVIDE BY

EXISTING BREAKER

WEATHER RESISTANT RECEPTACLE WITH GFCI

PROTECTION PROVIDED BY BREAKER AND WEATHER

PROOF COVER

RECEPTACLE, TWO DUPLEX IN A SINGLE DEVICE BOX

THE UPSTREAM ONE IS SURGE PROTECTED TYPE,

MOUNT FOR UNOBSTRUCTED ACCESS FOR RACK

MOUNTED EQUIPMENT

DATA OUTLET, TWO PORTS SEE SPECIFICATIONS

X-#

CIRCUIT TAG: "X" INDICATES PANEL, AND "#" IS THE

CIRCUIT NUMBER

BRANCH CIRCUIT: o - INDICATES GROUND, LONG LINE

- "NUETRAL" OR "GROUNDED CONDUCTOR" AND THE

SHORT LINE - "HOT" OR "LINE" CONDUCTORS

##" INDICATES UNUSUAL MOUNTING HEIGHT

a, b, c, ...

SMALL LETTERS INDICATE CONTROLLING DEVICES

AND CORRESPONDING CONTROLLED LUMINAIRES

INTAKE VENT TO REMAIN

EXHAUST VENT TO REMAIN

WALL CONSTRUCTION: WOOD SLATS, WIRE AND

PLASTER OVER STUDS, MAY ALSO HAVE GLUED ON

PANELING

WALL CONSTRUCTION: VARIES, PLASTER,

SHEETROCK, PANELING OR A COMBINATION OVER

BRICK, OFTEN GLUED

WALL CONSTRUCTION: SHEETROCK OVER STUDS,

MAY ALSO HAVE GLUED ON PANELING

S

C

M

S

A-1,3

A-2

A-4

A-12A-10

A-14

A-16

A-18

A-20

A-22

A-24

A-26

A-2

A-2

A-2

A-2

A-2

A-2

A-8

A-4

A-4

A-6

A-6

A-8

A-10

A-10

A-10

A-10

A-12

A-12

A-12

A-12

A-14

A-14

A-14

A-14

A-14

A-22

A-22

A-22

A-22

A-24 A-24

A-24

A-24 A-24

A-26

A-26

A-26

A-26

A-26 i i f f g g d d b a a a a

S1

F e

B

S

A A

M

P

P

M

M

M

S

S

S

C

B

S c

S c

M

M

M

M

M

S h

S h

S1A A k

S

TYPE DESCRIPTION MANUFACTURER MODEL # LAMPS MOUNTING

Qty

NOTES:

A DECORATIVE EXTERIOR WALL INCON LIGHTING 30211 9LED LED INCLUDED SURFACE/WALL 4

MOUNT TO EXISTING BOX WITH NEW CIRCUIT, SEE INSTALLATION NOTES

B CLOSE TO CEILING INCON LIGHTING 16111 13LED LED INCLUDED SURFACE/CEILING 2

P

KEYLESS LAMP HOLDER WITH

PULL CHAIN

ANY 13 WATT CFL SURFACE/CEILING 2

REUSE THE LAMP FROM THE TELECOMMUNICATIONS REMOVED LIGHT, THE OTHER LAMP

SHALL BE NEW

F EXHAUST FAN MARLEY 8060ES NOT APPLICABLE FLUSH/CEILING 1

REPLACES EXISTING FAN, REPAIR CEILING AS NEEDED, CONNECT TO DUCT TO EXTERIOR

S1 WALL PACK EXISTING SALVAGED EXISTING SURFACE/WALL 2

USE FIXTURE AS SPLICE BOX, DRILL HOLE THROUGH BRICK OR MORTAR FOR CIRCUIT FROM

ATTIC TO MOUNT AT LOCATION INDICATED, SEE PHOTOS

S2 1X4 FLUORESCENT EXISTING SALVAGED EXISTING SURFACE/CEILING 4

TOTAL 15

TYPE: EXISTING SQUARE D [QO-TYPE, 200 AMP, 30 CIRCUIT]

120/240 VAC

1 PHASE

FEEDER: EXISTING FROM 200 AMP METER MAIN

GROUNDING: #4 CU GRD TO WATER PIPES AND GROUND ROD OR

CONCRETE ENCASED ELECTRODE, SEE SPECIFICATIONS

CKT LOAD DESCRIPTION WATTS BREAKER AWG

LOAD (WATTS)

AWG BREAKER WATTS LOAD DESCRIPTION CKT

A B

AC CONDENSER

40 EX. 8

3760 12 20 EX 1260 RECEPTACLES-SOUTH WING SOUTH ROOM 2

3 2500 3040 12 20 EX 540 RECETPACLES-SOUTHWINGNORTHWEST ROOM WEST WALL 4

5 FURNACE 1500 QO120 12 1860 12 20 EX 360 RECEPTACLES-SOUTHWING NORTHWEST ROOM EAST COUNTER TOP 6

7 YARD GATE 1500 20 EX EX 1860 12 20 GFCI EX 360 RECEPTACLES-EXTERIOR AND BATHROOM 8

9 LIGHTS-NORTHWING QO115 14 900 12 20 EX 900 RECEPTACLES-MAIN AREA SOUTHWEST ROOM 10

11 LIGHTS-MAIN AREA QO115 14 900 12 QO120 900 RECEPTACLES-MAIN AREA SOUTHEAST ROOM 12

13 LIGHTS-SOUTHWING QO115 14 1080 12 QO120 1080 RECEPTACLES-MAIN AREA NORTHWEST ROOM 14

15 LIGHTS-EXTERIOR QO115 14 1500 12 QO120 1500 RECEPTACLES-TELECOM CLOSET 16

ALARM CIRCUIT (SMOKE AND CO)

Q0115 14 1500 12 QO120 1500 RECEPTACLE-WATER HEATER 18

19 1500 12 QO120 1500 RECEPTACLE-COUNTER ABOVE WATER HEATER 20

21 900 12 QO120 900 RECEPTACLES-MAIN AREA NORTHEAST ROOM 22

23 1080 12 QO120 1080 RECETPACLES-NORTHWING SOUTH ROOM 24

25 1080 12 QO120 1080 RECETPACLES-NORTHWING NORTH ROOM 26

27 #### 28

29 #### 30

CODE CALCULATED TOTAL LOAD (WATTS): LOAD PER PHASE: (WATTS)

11080 9880

A-13

A-5

A-13

A-13

A-13

A-13

A-11

A-9

A-9

A-11

A-11

A-11

A-11

A-11