AFMC_807.pdf

PDF 83 KB Posted

Attached to
Solicitation: FA8212-25-Q-0013 F-16 Power Dist. Panel
Solicitation number
FA8212-25-Q-0013
Issued by

About this file

This is an AFMC Form 807 specifying quality assurance provisions and special inspection requirements for an F-16 Power Distribution Panel (NSN: 6110016683072LE). The document indicates that inspection and acceptance must be performed at the source, citing DFARS 246.402, due to this being a critical F-16 component with significant technical requirements for manufacture, repair, and testing.

The form specifies standard inspection requirements under FAR 52.246-2,-3,-4,-5 or -6 as applicable to the contract. The quality standard must comply with LM Aero drawing 16F4423 and associated specifications. The document confirms this is for a previous source, not requiring a quality pre-award survey, and includes an ODS statement confirming no Class I ozone-depleting substances are required. The technical authority is Justin M. Allred from 416 SCMS/GUEAA, with Catherine T. Marum listed as the item manager and Jerry Frahm as the equipment specialist.

View the file

Other files

File Type Posted
FA82122-25-Q-0013.pdf PDF
IUID.pdf PDF
AFMC_158.pdf PDF
MANUFACTURING_QUALIFICATION_REQUIREMENTS_Section_C.pdf PDF
DD_FORM_1653.pdf PDF
PACKAGING_SOW.pdf PDF
ITEM_DESCRIPTION.pdf PDF
ENGINEERING_DATA_LIST.pdf PDF
ENGINEERING_DATA_REQUIREMENTS.pdf PDF
FA82122-25-Q-0013.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

6110016683072LE

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Marum, Catherine T / 801-586-4346

6. EQUIPMENT SPEC / PHONE

Frahm, Jerry / 801-775-4600

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

X STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

Allred, Justin MNAME: 21 NOV 2023DATE:

The quality standard should be in accordance with LM Aero drawing 16F4423 and associated specifications. Inspection must be accomplished at the source due to it being acritical item on the F-16 and the significant technical requirements for the manufacture, repair, and test of this item.

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

X PREVIOUS SOURCEX NO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

C

11. SIGNATURE OF TECHNICAL AUTHORITY

Allred, Justin M

ORGANIZATION / SYMBOL

416 SCMS / GUEAA

PHONE

801-775-4528 / 775-4528

DATE

21 NOV 2023

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 1Generated by PRPS using Jasper Reports on 10 Feb 2025

File details come from the government source that posted it. Updated .