This is a structural engineering calculation package for light pole footings at the VAMHCS Medical Center in Wilmington, Delaware, prepared by Whitney Bailey Cox & Magnani, LLC and dated February 21, 2024. The calculations analyze wind loads (based on Risk Category I, 105 mph ultimate wind speed), seismic parameters (Site Class D), and structural design requirements for concrete light pole footings and reinforcement. The design includes a 24-inch diameter concrete footing with 8-#5 reinforcing bars, embedded 5.625 feet deep to resist lateral and moment loads from the pole and luminaire. The light pole specification is a Valmont DS330 fatigue-resistant soft square steel post with integral arm mount, rated for wind speeds up to 90 mph and utilizing a Gardco EcoForm ECF-S small LED area luminaire capable of delivering up to 27,800 lumens.
The calculations verify the structural adequacy of both the footing embedment depth and reinforcement design under governing load combinations per IBC 2018, ASCE 7-16, and ACI 318-14 requirements. Key design parameters include a 140 lb pole weight, 240 lb fixture weight, combined wind area of 6.7 square feet, and maximum moment at base of 8,125 ft-lbs under the governing wind load case. The reinforced concrete footing is designed to resist these loads while maintaining soil pressures within allowable limits and providing adequate structural capacity per code requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24425B0002 0003_1.docx | DOCX document | |
| 36C24425B0002 0003.pdf | ||
| WD Heavy 2-7-25.pdf | ||
| Pre-Bid Site Visit_022825 Redacted.pdf | ||
| 36C24425B0002 0002_1.pdf | ||
| 36C24425B0002 0001_1.docx | DOCX document | |
| 36C24425B0002 0001.pdf | ||
| CAL101 Site LTG Cal.pdf | ||
| 36C24425B0002_2.docx | DOCX document | |
| 100_CDSubmissionCombineSet.pdf | ||
| 36C24425B0002 South Lot Paving IFB 2-20-25.pdf | ||
| 100_CDSubmissionMasterSpecifications.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VAMHCS MEDICAL CENTER
WILMINGTON, DELAWARE
LIGHT POLE FOOTING
DESIGN
CALCULATIONS
100% Submission
February 21, 2024
Prepared by:
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road, Suite 200 Baltimore, MD 21286 wbcm.com 2022.0714.00
VAMHCS MEDICAL CENTER
Wilmington, DE Light Pole Footing Design
Calculations i
Table of Contents
Basis of Design
Wind Speed
Wind Load Computation
Seismic Parameters
Seismic Load Computation
Light Pole Footing Size & Embedment Design
Light Pole Footing Reinforcement Design
\\A-e\balto\Projects\2023\23023600\Design\Structural\Calculation PACKAGE - 100% Submission - 02.21.2024\2023.0236.00 - VAMHCS MEDICAL CENTER WILMINGTON DE - 100%
Submission - Structural Calculation Package.DOCX
SPECIFICATIONS
DS330
Fatigue Resistant
Soft Square Steel Post
Job Name:
Job Location - City: State:
Product: Quote:
Client Name:
Created By: Date:
Customer Approval: Date:
VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM
Pole Shaft - The pole shaft is fabricated from hot rolled welded steel tubing of one-piece construction with a minimum yield strength of 55 KSI.
Pole Top – A removable pole cap is provided for poles receiving drilling patterns for side-mount luminaire arm assemblies. For top mount luminaire and/or bracket consult the factory. Consult the luminaire manufacturer for correct tenon size or drill pattern. Other pole top options include pole cap only (PC) or plain top (PL) which is typical when the pole top diameter matches the necessary slip fit dimensions.
Handhole – A reinforced handhole with grounding provision is provided at 1'-6" from the base end of the pole assembly. Each handhole includes an easy to install, self-contained Swing Latch handhole cover assembly. U.S.
Patent Swing Latch cover is fabricated from durable polycarbonate/ABS blend plastic. All pole assemblies are provided with a 2.50" x 5.00" rectangular handhole. Handhole dimensions are nominal.
Base Cover – A two-piece full base cover fabricated from ABS plastic is provided with each pole assembly. Additional base cover options, including the dart square (2T) cast aluminum cover, are available upon request.
Anchor Bolts - Anchor bolts conform to ASTM F1554 Grade 55 and are provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end and are galvanized a minimum of 12" on the threaded end.
Hardware - All structural fasteners are galvanized high strength carbon steel.
All non-structural fasteners are galvanized or zinc-plated carbon steel or stainless steel.
Finish - Standard finishes are either Galvanized (GV) or Finish Painted (FP).
Additional finish options including Finish Paint over Galvanizing (FPGV) or any of the V-PROTM Finish Coating Systems are available upon request. See the product ordering code for color options.
Design Criteria - Please reference Design Criteria Specification for appropriate design conditions.
Full Base Cover (Standard)
Pole Cap - Plastic
Handhole
1'-6"
N om in al
M ou nt in g H ei gh t
Tenon Top*
Dart Square - 2T (Optional)
Cross Section
Soft Square
Handhole
DS330
* Consult factory on loading criteria for pole top mounted luminaires and/or brackets.
DESIGNATION,LOAD AND DIMENSIONAL DATA
ANCHORAGE DATA
VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM
PRODUCT ORDERING CODES
Job Name:
Job Location - City: State:
Product: Quote:
Client Name:
Created By: Date:
Customer Approval: Date:
DS330
Fatigue Resistant Soft Square Steel Post
1. Maximum EPA (Effective Projected Area) and weight values are based on side mounted fixtures only. Consult factory on loading criteria for pole top mounted luminaires and/or brackets. Variations from sizes above are available upon inquiry at the factory. Satisfactory performance of poles is
| dependent upon the pole being properly attached to a supporting foundation of adequate design. | |
| 2. | Structure weight is a nominal value which includes the pole shaft and base plate only. |
| 3. | Belled-bottom will have reduced thickness due to the cold-working process. However, the belled-bottom meets or exceeds the structural capacity of |
| the original square section. In addition, the rounded section provides better fatigue resistance. |
90°
DESIGN INFORMATION POLE DIMENSIONS3
NOMINAL
MOUNTING
HEIGHT
80 MPH
w/1.3 GUST
90 MPH
w/1.3 GUST
100 MPH
w/1.3 GUST SHAFT
BASE
SQUARE3
(IN)
SHAFT
TOP
SQUARE
(IN)
WALL
THK
(GA)
STRUCTURE
WEIGHT2
(LBS)
MAX
EPA1
(SQ FT)
MAX
WEIGHT1
(LBS)
MAX
EPA1
(SQ FT)
MAX
WEIGHT1
(LBS)
MAX
EPA1
(SQ FT)
MAX
WEIGHT1
(LBS)
10'-0" 30.6 765 23.8 595 18.9 473 4.00 4.00 11 75 400Q100 12'-0" 24.4 610 18.8 470 14.8 370 4.00 4.00 11 90 400Q120 14'-0" 19.9 498 15.1 378 11.7 293 4.00 4.00 11 100 400Q140 16'-0" 15.9 398 11.8 295 8.9 223 4.00 4.00 11 115 400Q160 18'-0" 12.6 315 9.2 230 6.7 168 4.00 4.00 11 125 400Q180
20'-0"
9.6 240 6.7 167 4.5 150 4.00 4.00 11 140 400Q200
17.7 443 12.7 343 9.4 235 5.00 5.00 11 185 500Q200
28.1 703 21.4 535 16.2 405 5.00 5.00 7 265 500W200
25'-0"
4.8 150 2.6 100 1.0 50 4.00 4.00 11 170 400Q250
10.8 270 7.7 188 5.4 135 4.00 4.00 7 245 400W250
9.8 245 6.3 157 3.7 150 5.00 5.00 11 225 500Q250
18.5 463 13.3 333 9.5 238 5.00 5.00 7 360 500W250
30'-0"
6.7 168 4.4 110 2.6 65 4.00 4.00 7 291 400W300
4.7 150 2.0 50 N/A N/A 5.00 5.00 11 265 500Q300
10.7 267 6.7 167 3.9 100 5.00 5.00 7 380 500W300
19.0 475 13.2 330 9.0 225 6.00 6.00 7 520 600W300
35'-0" 5.9 150 2.5 100 N/A N/A 5.00 5.00 7 440 500W350
12.4 310 7.6 190 4.2 105 6.00 6.00 7 540 600W350
40'-0" 7.2 180 3.0 75 N/A N/A 6.00 6.00 7 605 600W400
DESIGNATION
POLE BASE PLATE ANCHOR BOLTS
POLE
BASE
SQUARE
(IN)
WALL
THK
(GA)
BOLT CIRCLE
SQUARE
(IN)
THK
(IN)
DIA x LENGTH x HOOK
(IN)
PROJECTION
(IN)
(IN)
DIA
(IN)
(IN)
4.00 11 8.50 0.50 8.25 0.750 0.75 x 17.00 x 3.00 3.50 0.25
4.00 7 8.50 0.50 8.25 0.875 0.75 x 17.00 x 3.00 3.63 0.25
5.00 11 11.00 1.00 11.00 1.000 0.75 x 17.00 x 3.00 3.75 0.25
5.00 7 11.00 1.00 11.00 1.000 0.75 x 17.00 x 3.00 3.75 0.25
6.00 7 12.00 1.00 12.50 1.000 1.00 x 36.00 x 4.00 4.25 0.25
0° - Handhole
270°90°
180°
Bolt Circle
Bolt Slots/Holes
As viewed from top of pole.
Anchor Base Detail
DS330
Drill Mounting (See Orientation) D1 = (1) Drilling @ 270° D2 = (2) Drillings @ 90° & 270° D4 = (4) Drillings @ 0°, 90°, 180°, & 270° D5 = (2) Drillings @ 180° & 270° D6 = (3) Drillings @ 90°, 180°, & 270°
Tenon Mounting P2 = 2.38" OD x 4" tenon P4 = 4.00" OD x 6" tenon P5 = 2.88" OD x 4" tenon P6 = 2.88" OD x 5" tenon P7 = 2.38" OD x 5" tenon P9 = Special Size (Specify)
Other Options PC = Pole Cap PL = Plain Top (No Cap)
| GV | = | Galvanized |
| FP = Finish Painted |
-----OPTIONAL-----
FPGV = Finish Paint
| over Galvanizing | |
| VP30 = V-PRO™ 30 System | |
| VP32 = V-PRO™ 32 System | |
| VP53 = V-PRO™ 53 System | |
| VP54 = V-PRO™ 54 System | |
| VP57 = V-PRO™ 57 System | |
| VP100 = V-PRO™ 100 System | |
| VP105 = V-PRO™ 105 System |
| GV | = | Galvanized | |
| BK | = | Black | |
| DB | = | Dark Bronze | |
| MB | = | Medium Bronze | |
| WH | = | White | |
| LG | = | Light Gray | |
| CB | = | Bronze | |
| DG | = | Dark Green | |
| ST | = | Sandstone | |
| HTG | = | Hunter Green | |
| SG | = | Slate Gray | |
| SL | = | Silver | |
| SC | = | Special Color | |
| (Specify) |
FBC = Full Base Cover
-----OPTIONAL-----
2T = Square Dart Cover
AB = With Anchor Bolts LAB = Without Anchor Bolts
Select Correct Designation from the Load and
Dimensional Data Chart.
DESIGNATIONMODEL FIXTURE MOUNTING FINISH SYSTEM STANDARD COLOR OPTIONS BASE COVER ANCHOR BOLTS SUPPLEMENTAL INFO
DS330
S P
C
2/ v al m on ts tru ct ur es .c om c ar rie s th e m os t c ur re nt s pe c in fo rm at io n an d su pe rs ed es th es e gu id el in es
400Q200 D2 FP -- FBC AB
DS330 - Fatigue Resistant Square Non-Tapered Steel Pole
S P
C
2/ v al m on ts tru ct ur es .c om c ar rie s th e m os t c ur re nt s pe c in fo rm at io n an d su pe rs ed es th es e gu id el in es
VALMONT INDUSTRIES, INC. 28800 IDA STREET, PO BOX 358 - VALLEY, NE 68064 USA 800.825.6668 VALMONTSTRUCTURES.COM
ECF-S_EcoForm_area_small 01/22 page 1 of 9
ECF-S EcoForm small Area luminaire
Project:
Location:
Cat.No:
Type:
Lamps: Qty:
Notes:
Gardco EcoForm Gen-2 combines economy with performance in an LED area luminaire. Capable of delivering up to 27,800 lumens or more in a compact, low profile LED luminaire, EcoForm offers a new level of customer value. EcoForm features an innovative retrofit arm kit, simplifying site conversions to LED by eliminating the need to drill additional holes in most existing poles. Integral control systems available for further energy savings. Includes Service Tag, our innovative way to provide assistance throughout the life of the product.
Ordering guide
Prefix
ECF-S
Number of LEDs Drive Current LED Color - Generation Mounting Distribution Voltage
ECF-S EcoForm site and area, small
32L 32 LEDs (2 modules)
48L 48 LEDs (3 modules)
64L 64 LEDs (4 modules)
| 365 | 365 mA |
| 530 | 530 mA |
| 700 | 700 mA |
| 1A | 1050 mA |
| 1.2A | 1200 mA |
| 900 | 900 mA |
| 1A | 1050 mA |
| 1.2A19 | 1200 mA |
| 900 | 900 mA |
| 1A19 | 1050 mA |
WW-G2 Warm White
3000K, 70 CRI
Generation 2
NW-G2 Neutral White
4000K, 70 CRI
Generation 2
CW-G2 Cool White
5000K, 70 CRI
Generation 2
AR2 Arm Mount (standard)
The following mounting kits must be ordered separately (See accessories)
SF3 Slip Fitter Mount (fits to 2 3⁄8" O.D. tenon)
WS Wall mount with surface conduit rear entry permitted
RAM2 Retrofit arm mount kit
Type 2
| 2 | Type 2 |
| 2-90 | Rotated left 90° |
| 2-270 | Rotated right 270° |
Type 3
| 3 | Type 3 |
| 3-90 | �Rotated left 90° |
| 3-270 | Rotated right 270° |
Type 4
| 4 | Type 4 |
| 4-90 | Rotated left 90° |
| 4-270 | Rotated right 270° |
Type 5
| 5 | Type 5 |
| 5W | Type 5W |
| AFR | Auto Front Row |
| AFR-90 | Auto Front Row, |
Rotated left 90° AFR-270 Auto Front Row, Rotated right 270°
| BLC | Back Light Control |
| BLC-90 | Back Light Control |
rotated at 90° BLC-270 Back Light Control rotated at 270°
LCL19 LEED Corner Optic Left
RCL19 LEED Corner Optic Right
| 120 | 120V |
| 208 | 208V |
| 240 | 240V |
| 277 | 277V |
| 347 | 347V |
| 480 | 480V |
| UNV | 120-277V |
(50/60Hz)
HVU 347-480V
(50/60Hz)
Options
FinishDimming controls Motion sensing lens Photo-sensing Electrical Luminaire
DD4.18 � 0-10V External dimming (for controls by others)
| DCC4,5,6,18 | � Dual Circuit Control |
| FAWS4,5,18 | � Field Adjustable Wattage Selector |
| LLC4,6,7,8,18 | � Integral wireless module |
| BL1,4,7,18 | Bi-level functionality |
| SRDR4,5,6,8,17 | SR driver connected to Zhaga socket |
DynaDimmer: Automatic Profile Dimming
| CS504,8 | � Safety 50% Dimming, 7 hours |
| CM504,8 | � Median 50% Dimming, 8 hours |
| CS304,8 | � Safety 30% Dimming, 7 hours |
| CM304,8 | � Median 30% Dimming, 8 hours |
IMRI315 Integral with #3 lens
IMRI716 Integral with #7 lens
PCB8,9 � Photocontrol Button
TLRD510,17 Twist Lock Receptacle 5 Pin
TLRD710,17 Twist Lock Receptacle 7 Pin
TLRPC9,10,11,17 Twist Lock Receptacle w/ Photocell
Fusing
| F19 | Single (120, 277, 347VAC) |
| F29 | Double (208, 240, 480VAC) |
Pole Mount Fusing
| FP19 | Single (120, 277, 347VAC) |
| FP29 | Double (208, 240, 480VAC) |
| FP39 | Canadian Double Pull |
(208, 240, 480VAC)
Surge Protection (10kA standard) SP2 � Increased 20kA
Square Pole Adapter included in standard product
| TB12 | Terminal Block |
| RPA13 | Round Pole |
Adapter (fits to 3"- 3.9" O.D. pole)
HIS14 Internal House Side Shield
Textured
| BK | Black |
| WH | White |
| BZ | Bronze |
| DGY | Dark Gray |
| MGY | Medium Gray |
Customer specified RAL Specify optional color or RAL (ex: RAL7024)
CC Custom color (Must supply color chip for required factory quote)
1. BL-IMRI3/7 equipped with out-boarded sensor housing when voltage is HVU (347-480V)
2. Mounts to a 4" round pole with adapter included for square poles.
| 3. | Limited to a maximum of 45 degrees aiming above horizontal. |
| 4. | Not available with other dimming control options. |
| 5. | Not available with motion sensor. |
| 6. | Not available with photocontrol. |
| 7. | Must specify a motion sensor lens. |
| 8. | Not available in 347 or 480V |
| 9. | Must specify input voltage. |
10. TLRD5, TLRD7 and TLRPC receptacle pins 4 & 5 are capped off when ordered with any of the Dimming controls DD or FAWS or LLC.
| 11. | Not available in 480V. Order photocell separately with TLRD5/7. |
| 12. | Not available with DCC. |
| 13. | Not available with SF and WS. RPAs provided with black |
finish standard.
14. HIS not available with Type 5, 5W, BLC, BLC-90, BLC-270, LCL or RCL optics.
15. Not available with DD, DCC, and FAWS dimming control options.
16. Not available with DD, DCC, FAWS and LLC dimming control options.
17. When ordering SRDR, controller (by others) to be used on socket must be SR compatible (See specifications for more details). Consult factory for lead time. All 7 pins in NEMA receptacle are connected to SR driver. SRDR not available with TLRD5 or TLRPC.
18. 0-10V dimming driver standard.
19. LCL and RCL not available with 48L-1.2A or 64L-1A.
Site & Area
EcoForm
ECF-S small area light example: ECF-S-64L-900-NW-G2-AR-5-120-HIS-MGY
ECF-S_EcoForm_area_small 01/22 page 2 of 9
Area luminaire
Shielding Accessories
House Side shield Standard optic orientation:
| HIS-32-H 20 | � Internal House Side Shield for 32 LEDs (2 modules) |
| HIS-48-H 20 | � Internal House Side Shield for 48 LEDs (3 modules) |
| HIS-64-H 20 | � Internal House Side Shield for 64 LEDs (4 modules) |
Optic at 90 or 270 orientation:
| HIS-32-V 20 | � Internal House Side Shield for 32 LEDs (2 modules) |
| HIS-48-V 20 | � Internal House Side Shield for 48 LEDs (3 modules) |
| HIS-64-V 20 | � Internal House Side Shield for 64 LEDs (4 modules) |
EcoForm Accessories 21 (ordered separately, field installed)
Ready to Go configurations (when ordered with the "RS-" catalog code, the following configurations will ship in 2 weeks):
Luminaire Accessories
| ECF-BD-G2 | Bird deterrent |
| ECF-RAM-G2-(F) | Retrofit Arm mount kit |
| ECF-SF-G2-(F) | � Slip Fitter Mount (fits to 2 3⁄8" O.D. tenon) |
| ECF-WS-G2-(F) | � Wall mount with surface conduit rear entry permitted |
EcoForm PTF2 (pole top fitter fits 23⁄8-21⁄2" OD x 4" depth tenon)
| PTF2-ECF-S/L-1-90-(F) | 1 luminaire at 90° |
| PTF2-ECF-S/L-2-90-(F) | 2 luminaires at 90° |
| PTF2-ECF-S/L-2-180-(F) | 2 luminaires at 180° |
| PTF2-ECF-S/L-3-90-(F) | 3 luminaires at 90° |
| PTF2-ECF-S/L-4-90-(F) | 4 luminaires at 90° |
| PTF2-ECF-S/L-3-120-(F) | 3 luminaires at 120° |
(F) = Specify finish
EcoForm PTF3 (pole top fitter fits 3-31⁄2" OD x 6" depth tenon)
| PTF3-ECF-S/L-1-90-(F) | 1 luminaire at 90° |
| PTF3-ECF-S/L-2-90-(F) | 2 luminaires at 90° |
| PTF3-ECF-S/L-2-180-(F) | 2 luminaires at 180° |
| PTF3-ECF-S/L-3-90-(F) | 3 luminaires at 90° |
| PTF3-ECF-S/L-4-90-(F) | 4 luminaires at 90° |
| PTF3-ECF-S/L-3-120-(F) | 3 luminaires at 120° |
EcoForm PTF4 (pole top fitter fits 31⁄2-4" OD x 6" depth tenon)
| PTF4-ECF-S/L-1-90-(F) | 1 luminaire at 90° |
| PTF4-ECF-S/L-2-90-(F) | 2 luminaires at 90° |
| PTF4-ECF-S/L-2-180-(F) | 2 luminaires at 180° |
| PTF4-ECF-S/L-3-90-(F) | 3 luminaires at 90° |
| PTF4-ECF-S/L-4-90-(F) | 4 luminaires at 90° |
| PTF4-ECF-S/L-3-120-(F) | 3 luminaires at 120° |
20. Not available with Type 5 or 5W optics
21. �Consult Signify to confirm whether specific accessories are BAA-compliant.
Footnotes
Catalog Number 12NC
RS-ECF-S-32L-1A-NW-G2-AR-3-UNV-BZ 912401466002
RS-ECF-S-32L-1A-NW-G2-AR-3-UNV-MGY 912401466003
RS-ECF-S-32L-1A-NW-G2-AR-3-UNV-BK 912401534554
RS-ECF-S-32L-1A-NW-G2-AR-4-UNV-BZ 912401466004
RS-ECF-S-32L-1A-NW-G2-AR-4-UNV-MGY 912401466005
RS-ECF-S-32L-1A-NW-G2-AR-4-UNV-BK 912401534555
RS-ECF-S-32L-1A-NW-G2-AR-5-UNV-BZ 912401466006
RS-ECF-S-32L-1A-NW-G2-AR-5-UNV-MGY 912401466007
RS-ECF-S-32L-1A-NW-G2-AR-5-UNV-BK 912401534556
RS-ECF-S-48L-1A-NW-G2-AR-3-UNV-BZ 912401466008
RS-ECF-S-48L-1A-NW-G2-AR-3-UNV-MGY 912401466009
RS-ECF-S-48L-1A-NW-G2-AR-3-UNV-BK 912401534557
RS-ECF-S-48L-1A-NW-G2-AR-4-UNV-BZ 912401466010
RS-ECF-S-48L-1A-NW-G2-AR-4-UNV-MGY 912401466011
RS-ECF-S-48L-1A-NW-G2-AR-4-UNV-BK 912401534558
RS-ECF-S-48L-1A-NW-G2-AR-5-UNV-BZ 912401466012
RS-ECF-S-48L-1A-NW-G2-AR-5-UNV-MGY 912401466013
RS-ECF-S-48L-1A-NW-G2-AR-5-UNV-BK 912401534559
RS-ECF-S-64L-1A-NW-G2-AR-3-UNV-BZ 912401466014
RS-ECF-S-64L-1A-NW-G2-AR-3-UNV-MGY 912401466015
Catalog Number 12NC
RS-ECF-S-64L-1A-NW-G2-AR-3-UNV-BK 912401534560
RS-ECF-S-64L-1A-NW-G2-AR-4-UNV-BZ 912401466016
RS-ECF-S-64L-1A-NW-G2-AR-4-UNV-MGY 912401466017
RS-ECF-S-64L-1A-NW-G2-AR-4-UNV-BK 912401534561
RS-ECF-S-64L-1A-NW-G2-AR-5-UNV-BZ 912401466018
RS-ECF-S-64L-1A-NW-G2-AR-5-UNV-MGY 912401466019
RS-ECF-S-64L-1A-NW-G2-AR-5-UNV-BK 912401534562
RS-ECF-RAM-G2-DGY 912401466487
RS-ECF-RAM-G2-MGY 912401466488
RS-ECF-RAM-G2-WH 912401466485
RS-ECF-RAM-G2-BZ 912401466486
RS-ECF-RAM-G2-BK 912401466484
RS-HIS-32-H 912401466489
RS-HIS-48-H 912401466491
RS-HIS-64-H 912401466493
ECF-S_EcoForm_area_small 01/22 page 3 of 9
Area luminaire
Optical Distributions Based on configuration ECF-S-48L-1A-NW-G2 (159W) mounted at 20ft.
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
AFR
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
0.2 fc
0.5 fc
1 fc 2 fc
Type 2
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
Type 3
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
Type 4
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
BLC
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
Type 5
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
Type 5W
0.2 fc
0.5 fc
1 fc 2 fc
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
LCL
0.2 fc
0.5 fc
1 fc
2 fc
0.2 fc
0.5 fc
1 fc
2 fc
0.2 fc
0.5 fc
1 fc2 fc
0.2 fc
0.5 fc
1 fc
2 fc
0.2 fc
0.5 fc1 fc
2 fc
0.1 fc 0.2 fc
0.5 fc
1.0 fc
1 MH2 MH3 MH 1 MH 2 MH 3 MH 5 MH5 MH
1 MH
2 MH
3 MH
1 MH
2 MH
3 MH
4 MH 4 MH
4 MH
4 MH
RCL
0.1 fc 0.2 fc
0.5 fc
1.0 fc
Predicted Lumen Depreciation Data Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on IESNA LM-80 methodology.
Actual experience may vary due to field application conditions.L70 is the predicted time when LED performance depreciates to 70% of initial lumen output. Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours
Ambient Temperature °C Driver mA Calculated L70 Hours L70 per TM-21 Lumen Maintenance % at 60,000 hrs
25°C up to 1200 mA >100,000 hours >120,000 hours >99%
ECF-S_EcoForm_area_small 01/22 page 4 of 9
Area luminaire 3000K LED Wattage and Lumen Values
4000K LED Wattage and Lumen Values
Ordering Code Total LEDs
LED
Current
(mA) Color Temp.
Average System Watts
Type 2 Type 3 Type 4 Type 5 Type 5W
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
ECF-S-32L-365-WW-G2-x 32 365 3000 40 5,508 B1-U0-G1 138 5,428 B1-U0-G2 136 5,637 B1-U0-G2 141 5,790 B3-U0-G1 145 5,604 B3-U0-G1 140
ECF-S-32L-530-WW-G2-x 32 530 3000 56 7,159 B2-U0-G2 129 7,055 B1-U0-G2 127 7,327 B1-U0-G2 132 7,526 B3-U0-G2 135 7,284 B3-U0-G2 131
ECF-S-32L-700-WW-G2-x 32 700 3000 73 9,234 B2-U0-G2 127 9,034 B2-U0-G2 124 9,452 B2-U0-G2 130 9,707 B4-U0-G2 133 9,395 B4-U0-G2 129
ECF-S-32L-1A-WW-G2-x 32 1050 3000 106 13,001 B3-U0-G2 123 12,719 B2-U0-G2 120 13,306 B2-U0-G3 126 13,665 B4-U0-G2 129 13,227 B4-U0-G2 125
ECF-S-32L-1.2A-WW-G2-x 32 1200 3000 122 14,421 B3-U0-G3 119 14,108 B2-U0-G3 116 14,760 B2-U0-G3 121 15,158 B4-U0-G2 125 14,671 B4-U0-G2 121
ECF-S-48L-900-WW-G2-x 48 900 3000 135 17,115 B3-U0-G3 127 16,744 B3-U0-G3 124 17,518 B2-U0-G3 130 17,990 B4-U0-G2 133 17,413 B5-U0-G3 129
ECF-S-48L-1A-WW-G2-x 48 1050 3000 159 19,381 B3-U0-G3 122 18,960 B3-U0-G3 119 19,836 B3-U0-G4 125 20,372 B5-U0-G3 128 19,717 B5-U0-G3 124
ECF-S-48L-1.2A-WW-G2-x 48 1200 3000 183 21,515 B3-U0-G3 118 21,048 B3-U0-G4 115 22,020 B3-U0-G4 121 22,616 B5-U0-G3 124 21,888 B5-U0-G3 120
ECF-S-64L-900-WW-G2-x 64 900 3000 178 22,652 B3-U0-G3 127 22,161 B3-U0-G4 125 23,185 B3-U0-G4 130 23,810 B5-U0-G3 134 23,045 B5-U0-G3 130
ECF-S-64L-1A-WW-G2-x 64 1050 3000 206 25,520 B3-U0-G3 124 24,966 B3-U0-G4 121 26,120 B3-U0-G4 127 26,150 B5-U0-G3 127 25,964 B5-U0-G4 126
Ordering Code Total LEDs
LED
Current
(mA) Color Temp.
Average System Watts
Type 2 Type 3 Type 4 Type 5 Type 5W
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
ECF-S-32L-365-NW-G2-x 32 365 4000 40 5,798 B1-U0-G1 145 5,713 B1-U0-G2 143 5,934 B1-U0-G2 148 6,094 B3-U0-G1 152 5,898 B3-U0-G2 147
ECF-S-32L-530-NW-G2-x 32 530 4000 56 7,536 B2-U0-G2 135 7,426 B1-U0-G2 133 7,713 B1-U0-G2 138 7,922 B3-U0-G2 142 7,667 B3-U0-G2 138
ECF-S-32L-700-NW-G2-x 32 700 4000 73 9,720 B2-U0-G2 133 9,509 B2-U0-G2 130 9,949 B2-U0-G2 136 10,218 B4-U0-G2 140 9,889 B4-U0-G2 136
ECF-S-32L-1A-NW-G2-x 32 1050 4000 106 13,685 B3-U0-G2 130 13,388 B2-U0-G3 127 14,006 B2-U0-G3 133 14,384 B4-U0-G2 136 13,923 B4-U0-G2 132
ECF-S-32L-1.2A-NW-G2-x 32 1200 4000 122 15,180 B3-U0-G3 125 14,851 B2-U0-G3 122 15,537 B2-U0-G3 128 15,956 B4-U0-G2 131 15,443 B4-U0-G2 127
ECF-S-48L-900-NW-G2-x 48 900 4000 135 18,016 B3-U0-G3 133 17,625 B3-U0-G3 130 18,440 B3-U0-G3 136 18,937 B4-U0-G3 140 18,329 B5-U0-G3 136
ECF-S-48L-1A-NW-G2-x 48 1050 4000 159 20,401 B3-U0-G3 129 19,958 B3-U0-G4 126 20,880 B3-U0-G4 132 21,444 B5-U0-G3 135 20,755 B5-U0-G3 131
ECF-S-48L-1.2A-NW-G2-x 48 1200 4000 183 22,647 B3-U0-G3 124 22,156 B3-U0-G4 121 23,179 B3-U0-G4 127 23,806 B5-U0-G3 130 23,040 B5-U0-G3 126
ECF-S-64L-900-NW-G2-x 64 900 4000 178 23,844 B3-U0-G3 134 23,327 B3-U0-G4 131 24,405 B3-U0-G4 137 25,063 B5-U0-G3 141 24,258 B5-U0-G4 136
ECF-S-64L-1A-NW-G2-x 64 1050 4000 206 26,863 B3-U0-G3 130 26,280 B3-U0-G4 128 27,495 B3-U0-G4 134 27,526 B5-U0-G3 134 27,330 B5-U0-G4 133
Ordering Code Total LEDs
LED
Current
(mA) Color Temp.
Average System Watts
Type AFR BLC LCL or RCL
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
ECF-S-32L-365-WW-G2-x 32 365 3000 40 5,706 B2-U0-G1 143 3,691 B0-U0-G1 94 2,449 B0-U0-G1 62
ECF-S-32L-530-WW-G2-x 32 530 3000 56 7,417 B2-U0-G1 133 5,005 B0-U0-G2 91 3,183 B0-U0-G1 58
ECF-S-32L-700-WW-G2-x 32 700 3000 73 9,567 B2-U0-G2 131 6,409 B0-U0-G2 89 4,106 B0-U0-G1 57
ECF-S-32L-1A-WW-G2-x 32 1050 3000 106 13,467 B3-U0-G2 128 9,024 B1-U0-G2 87 5,793 B0-U0-G2 56
ECF-S-32L-1.2A-WW-G2-x 32 1200 3000 122 14,939 B3-U0-G2 123 10,010 B1-U0-G2 84 6,426 B0-U0-G2 54
ECF-S-48L-900-WW-G2-x 48 900 3000 135 17,731 B3-U0-G2 131 11,880 B1-U0-G2 89 7,626 B0-U0-G2 57
ECF-S-48L-1A-WW-G2-x 48 1050 3000 159 20,076 B3-U0-G2 127 13,453 B1-U0-G2 86 8,636 B0-U0-G2 55
ECF-S-48L-1.2A-WW-G2-x 48 1200 3000 183 22,288 B3-U0-G2 122 14,934 B1-U0-G3 83
ECF-S-64L-900-WW-G2-x 64 900 3000 178 23,465 B3-U0-G2 132 15,723 B1-U0-G3 90 10,093 B0-U0-G2 58
ECF-S-64L-1A-WW-G2-x 64 1050 3000 206 26,437 B4-U0-G3 128 17,714 B1-U0-G3 87
Ordering Code Total LEDs
LED
Current
(mA) Color Temp.
Average System Watts
Type AFR BLC LCL or RCL
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
ECF-S-32L-365-NW-G2-x 32 365 4000 40 6,006 B2-U0-G1 150 3,991 B0-U0-G1 101 2,633 B0-U0-G1 67
ECF-S-32L-530-NW-G2-x 32 530 4000 56 7,807 B2-U0-G1 140 5,412 B0-U0-G2 99 3,423 B0-U0-G1 62
ECF-S-32L-700-NW-G2-x 32 700 4000 73 10,070 B2-U0-G2 138 6,930 B0-U0-G2 96 4,415 B0-U0-G1 61
ECF-S-32L-1A-NW-G2-x 32 1050 4000 106 14,176 B3-U0-G2 134 9,756 B1-U0-G2 94 6,229 B0-U0-G2 60
ECF-S-32L-1.2A-NW-G2-x 32 1200 4000 122 15,725 B3-U0-G2 129 10,822 B1-U0-G2 90 6,910 B0-U0-G2 58
ECF-S-48L-900-NW-G2-x 48 900 4000 135 18664, B3-U0-G2 138 12,843 B1-U0-G2 96 8,200 B0-U0-G2 62
ECF-S-48L-1A-NW-G2-x 48 1050 4000 159 21,133 B3-U0-G2 133 14,544 B1-U0-G3 93 9,286 B0-U0-G2 59
ECF-S-48L-1.2A-NW-G2-x 48 1200 4000 183 23,461 B3-U0-G2 128 16,145 B1-U0-G3 90
ECF-S-64L-900-NW-G2-x 64 900 4000 178 24,700 B3-U0-G2 139 16,998 B1-U0-G3 97 10,853 B0-U0-G2 62
ECF-S-64L-1A-NW-G2-x 64 1050 4000 206 27,828 B4-U0-G3 135 19,150 B1-U0-G3 94
ECF-S_EcoForm_area_small 01/22 page 5 of 9
Area luminaire 5000K LED Wattage and Lumen Values
Ordering Code Total LEDs
LED
Current
(mA) Color Temp.
Average System Watts
Type 2 Type 3 Type 4 Type 5 Type 5W
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
ECF-S-32L-365-CW-G2-x 32 365 5000 40 5,798 B1-U0-G1 145 5,713 B1-U0-G2 143 5,934 B1-U0-G2 148 6,094 B3-U0-G1 152 5,898 B3-U0-G2 147
ECF-S-32L-530-CW-G2-x 32 530 5000 56 7,536 B2-U0-G2 135 7,426 B1-U0-G2 133 7,713 B1-U0-G2 138 7,922 B3-U0-G2 142 7,667 B3-U0-G2 138
ECF-S-32L-700-CW-G2-x 32 700 5000 73 9,720 B2-U0-G2 133 9,509 B2-U0-G2 130 9,949 B2-U0-G2 136 10,218 B4-U0-G2 140 9,889 B4-U0-G2 136
ECF-S-32L-1A-CW-G2-x 32 1050 5000 106 13,685 B3-U0-G2 130 13,388 B2-U0-G3 127 14,006 B2-U0-G3 133 14,384 B4-U0-G2 136 13,923 B4-U0-G2 132
ECF-S-32L-1.2A-CW-G2-x 32 1200 5000 122 15,180 B3-U0-G3 125 14,851 B2-U0-G3 122 15,537 B2-U0-G3 128 15,956 B4-U0-G2 131 15,443 B4-U0-G2 127
ECF-S-48L-900-CW-G2-x 48 900 5000 135 18,016 B3-U0-G3 133 17,625 B3-U0-G3 130 18,440 B3-U0-G3 136 18,937 B4-U0-G3 140 18,329 B5-U0-G3 136
ECF-S-48L-1A-CW-G2-x 48 1050 5000 159 20,401 B3-U0-G3 129 19,958 B3-U0-G4 126 20,880 B3-U0-G4 132 21,444 B5-U0-G3 135 20,755 B5-U0-G3 131
ECF-S-48L-1.2A-CW-G2-x 48 1200 5000 183 22,647 B3-U0-G3 124 22,156 B3-U0-G4 121 23,179 B3-U0-G4 127 23,806 B5-U0-G3 130 23,040 B5-U0-G3 126
ECF-S-64L-900-CW-G2-x 64 900 5000 178 23,844 B3-U0-G3 134 23,327 B3-U0-G4 131 24,405 B3-U0-G4 137 25063 B5-U0-G3 141 24258 B5-U0-G4 136
ECF-S-64L-1A-CW-G2-x 64 1050 5000 206 26,863 B3-U0-G3 130 26,280 B3-U0-G4 128 27,495 B3-U0-G4 134 27526 B5-U0-G3 134 27330 B5-U0-G4 133
Ordering Code Total LEDs
LED
Current
(mA) Color Temp.
Average System Watts
Type AFR BLC LCL or RCL
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
Lumen Output
BUG
Rating
Efficacy
(LPW)
ECF-S-32L-365-CW-G2-x 32 365 5000 40 6,006 B2-U0-G1 150 3,991 B0-U0-G1 101 2,633 B0-U0-G1 67
ECF-S-32L-530-CW-G2-x 32 530 5000 56 7,807 B2-U0-G1 140 5,412 B0-U0-G2 99 3,423 B0-U0-G1 62
ECF-S-32L-700-CW-G2-x 32 700 5000 73 10,070 B2-U0-G2 138 6,930 B0-U0-G2 96 4,415 B0-U0-G1 61
ECF-S-32L-1A-CW-G2-x 32 1050 5000 106 14,176 B3-U0-G2 134 9,756 B1-U0-G2 94 6,229 B0-U0-G2 60
ECF-S-32L-1.2A-CW-G2-x 32 1200 5000 122 15,725 B3-U0-G2 129 10,822 B1-U0-G2 90 6,910 B0-U0-G2 58
ECF-S-48L-900-CW-G2-x 48 900 5000 135 18,664 B3-U0-G2 138 12,843 B1-U0-G2 96 8,200 B0-U0-G2 62
ECF-S-48L-1A-CW-G2-x 48 1050 5000 159 21,133 B3-U0-G2 133 14,544 B1-U0-G3 93 9,286 B0-U0-G2 59
ECF-S-48L-1.2A-CW-G2-x 48 1200 5000 183 23,461 B3-U0-G2 128 16,145 B1-U0-G3 90
ECF-S-64L-900-CW-G2-x 64 900 5000 178 24,700 B3-U0-G2 139 16,998 B1-U0-G3 97 10,853 B0-U0-G2 62
ECF-S-64L-1A-CW-G2-x 64 1050 5000 206 27,828 B4-U0-G3 135 19,150 B1-U0-G3 94
ECF-S_EcoForm_area_small 01/22 page 6 of 9
Area luminaire
Dimensions
Standard Arm (AR) Weight: 22 Lbs (9.9 Kg) EPA: 0.21ft2 (.019m2)
Retrofit Arm (RAM) Weight: 24 Lbs (10.9 Kg) EPA: 0.24ft2 (.022m2)
Slip fitter (SF) Weight: 27 Lbs (12.2 Kg) EPA: 0.33ft2 (.031m2)
Wall (WS) Weight: 27 Lbs. (12. 2Kg) EPA: 0.27ft2 (.025m2)
6.5" (16.5cm)
28.7" (73cm)
14.9" (37.9cm)
2.2" (5.7cm)
1.3" (3.2cm)
28.7" (73cm)
7.0" (17.8cm)
5.0" (12.7cm) 3.6"
(9cm)
14.9" (37.9cm)
5.4" (13.6cm)
9.7" (24.7cm)
15.4" (39.2cm) 37.2" (94.4cm)
37.2" (94.4cm)
5.0" (12.7cm)
27.5" (69.7cm)
14.9" (37.9cm)
2.4" (6cm)
27.5" (69.7cm)
5.7" (14.6cm)
7.6" (19.4cm)
29.3" (74.5cm)
6.5" (16.5cm)
14.9" (37.9cm)
29.3" (74.5cm)
2.0" (5.1cm)
Outboard IMR-HVU sensor Retrofit Arm (RAM) drill pattern
Standard Arm (AR) drill pattern
3.1" (7.9cm)
3.4" (8.6cm)
5.3" (13.4cm)
4.7" (11.9cm)
0.41" (1.04cm)
1.0" (2.5cm)
0.41" (1.04cm)
5.2" (13.2cm)
1.0" (2.5cm)
2" (5.1cm)
0.41" (1.04cm)
1.0" (2.5cm)
0.41" (1.04cm)
3" (7.6cm)
1.0" (2.5cm)
1.0" (2.5cm)
ECF-S_EcoForm_area_small 01/22 page 7 of 9
Area luminaire
Optical Orientation Information
Standard Optic Position
Luminaires ordered with asymmetric optical systems in the standard optic position will have the optical system oriented as shown below:
Optic Rotated Right (270°) Optic Position
Luminaires ordered with optical systems in the Optic Rotated Right (270°) optic position will have the optical system oriented as shown below (Type 5 and 5W optics are not available with factory set rotatable optics):
Optic Rotated Left (90°) Optic Position
Luminaires ordered with optical systems in the Optic Rotated Left (90°) optic position will have the optical system oriented as shown below (Type 5 and 5W optics are not available with factory set rotatable optics):
Twin Luminaire Assemblies with Type-90/Type-270 Rotated Optical Systems
Twin luminaire assemblies installed with rotated optical systems are an excellent way to direct light toward the interior of the site (Street Side) without additional equipment. It is important, however, that care be exercised to insure that luminaires are installed in the proper location.
Street Side Street Side
House Side House Side
Curbline Curbline
Right side of pole
Left side of pole
0° 0°
270° 270° 90° 90°
Note: The hand hole will normally be located on the pole at the 0° point.
Note: The hand hole will normally be located on the pole at the 0° point.
Right side of pole
Left side of pole
Street Side
House Side
Curbline
Right side of pole
Left side of pole
0°
270° 90°
Note: The hand hole will normally be located on the pole at the 0° point.
Note: The hand hole location will depend on the drilling configuration ordered for the pole.
Luminaires with Optic Rotated Right (270°) are installed on the LEFT Side of Pole
Luminaires with Optic Rotated Left (90°) are installed on the RIGHT Side of Pole
Street Side
House Side
Curbline
0°
Right side of pole
Left side of pole
Luminaire with Type-270
Luminaire with Type-90
180°
ECF-S_EcoForm_area_small 01/22 page 8 of 9
Area luminaire
Housing One-piece die cast aluminum housing with integral arm and separate, self-retained hinged, one-piece die cast door frame. Luminaire housing rated to IP65, tested in accordance to Section 9 of IEC 60598-1.
Vibration resistance Luminaire is tested and rated 3G over 100,000 cycles conforming to standards set forth by ANSI C136.31-2018. Testing includes vibration in three axes, all performed on the same luminaire.
Light engine Light engine comprises of a module of 16-LED aluminum metal clad board fully sealed with optics offered in multiples of 2, 3, and 4 modules or 32, 48, and 64 LEDs. Module is RoHS compliant. Color temperatures: 3000K +/-125K, 4000K, 5000K +/- 200K. Minimum CRI of 70. LED light engine is rated IP66 in accordance to Section 9 of IEC 60598-1.
Energy saving benefits System efficacy up to 152 lms/W with significant energy savings over Pulse Start Metal Halide luminaires. Optional control options provide added energy savings during unoccupied periods.
Optical systems Type 2, 3, 4, 5, 5W, and AFR distributions available. Internal Shield option mounts to LED optics and is available with Type 2, 3, 4, and AFR distributions, including a dedicated BLC, LCL, and RCL optics to provide the best backlight control possible for those stringent requirements around property lines.
Types 2, 3, 4, AFR, and BLC when specified and used as rotated, are factory set only. Performance tested per LM-79 and TM-15 (IESNA) certifying its photometric performance. Luminaire designed with 0% uplight (U0 per
IESNA TM-15).
Mounting Standard luminaire arm mounts to 4" O.D. round poles. Can also be used with 5" O.D. poles. Square pole adapter included with every luminaire. Round Pole Adapter (RPA) required for 3-3.9" poles. EcoForm features a retrofit arm kit. When specified with the retrofit arm (RAM) option, EcoForm seamlessly simplifies site conversions to LED by eliminating the need for additional pole drilling on most existing poles. RAM will be boxed separately. Also optional are slipfitter and wall mounting accessories. Note that only fixed mounts (AR, RAM, WS) are required to meet IDA compliance. SF mounting will not meet IDA.
Control options 0-10V dimming (DD): Access to 0-10V dimming leads supplied through back of luminaire (for secondary dimming controls by others). Cannot be used with other control options.
Dual Circuit Control (DCC): Luminaire equipped with the ability to have two separate circuits controlling drivers and light engines independently. Permits separate switching of separate modules controlled by use of two sets of leads, one for each circuit. Not recommended to be used with other control options, motion response, or photocells.
Sensor Ready Zhaga Socket Connector (SRDR): Product equipped with Sensor Ready drivers connected to 4-pin Zhaga Book 18 compliant receptacle designed for sensor and other control system applications. Receptacle is rated IP66 assembly in a compact design that provides a sealed electrical interface and rated UV resistance, mounted on underside of the luminaire, protective dust cap included. When a controller not provided by Signify is used with Sensor Ready Zhaga socket connector, the controller must be certified to work with the Xitanium SR LED drivers as part of the SR certified program. SRDR can be used with NEMA 7-pin twist lock receptacle, which is mounted on top of the luminaire.
Automatic Profile Dimming (CS/CM/CE/CA): Standard dimming profiles provide flexibility towards energy savings goals while optimizing light levels during specific dark hours. Dimming profiles include two dimming settings including dim to 30% or 50% of the total lumen output. When used in combination with not programmed motion response it overrides the controller’s schedule when motion is detected. After 5 minutes with no motion, it will return to the automatic diming profile schedule. Automatic dimming profile scheduled with the following settings:
| • | CS50/CS30: Security for 7 hours night duration (Ex., 11 PM - 6 AM) |
| • | CM50/CM30: Median for 8 hours night duration (Ex., 10 PM - 6 AM) |
All above profiles are calculated from mid point of the night. Dimming is set for 6 hours after the mid point and 1 or 2 hours before depending of the duration of dimming. Cannot be used with other dimming control options.
Field Adjustable Wattage Selector (FAWS): Luminaire equipped with the ability to manually adjust the wattage in the field to reduce total luminaire lumen output and light levels. Comes pre-set to the highest position at the lumen output selected. Use chart below to estimate reduction in lumen output desired. Cannot be used with other control options or motion response.
Wireless system (LLC): Optional wireless controller integral to luminaire ready to be connected to a Limelight system (sold by others). The system allows you to wirelessly manage the entire site, independent lighting groups or individual luminaires while on-site or remotely. Based on a high-density mesh network with an easy to use web-based portal, you can conveniently access, monitor and manage your lighting network remotely. Wireless controls can be combined with site and area, pedestrian, and parking garage luminaires as well, for a completely connected outdoor solution. Equipped with motion response with #3 lens for 8-25' mounting heights. Also available with remote pod accessory where pod is mounted separate from luminaire to pole or wall.
Motion response options Bi-Level Infrared Motion Response (BL-IMRI): Motion Response module is mounted integral to luminaire factory pre-programmed to 50% dimming when not ordered with other control options. BL-IMRI is set/operates in the following fashion: The motion sensor is set to a constant 50%. When motion is detected by the PIR sensor, the luminaire returns to full power/light output.
Dimming on low is factory set to 50% with 5 minutes default in "full power" prior to dimming back to low. When no motion is detected for 5 minutes, the motion response system reduces the wattage by 50%, to 50% of the normal constant wattage reducing the light level. Other dimming settings can be provided if different dimming levels are required. This can also be done with FSIR-100 Wireless Remote Programming Tool (contact Technical Support for details).
Infrared Motion Response with Other Controls: When used in combination with other controls (Automatic Dimming Profile), motion response device will simply override controller’s schedule with the added benefits of a combined dimming profile and sensor detection. In this configuration, the motion response device cannot be re-programmed with FSIR-100 Wireless Remote Programming Tool. The profile can only be re-programmed via the controller.
FAWS
Position
Percent of Typical Lumen Output
1 25%
2 50%
3 55%
4 65%
5 75%
6 80%
7 85%
8 90%
9 95%
10 100%
Note: Typical value accuracy +/- 5%
30' 27'
20'
12'
6' 3'
3' 6'
12'
20'
27'
30'
0' 60'
0'
10'
20'
30'
40'
0'
20'
10'
10'
20'
40' 10'
20'
0'
15'
5'
0'
8' 0' 3'3' 7'7' 11' '42'1124'
30'
20'
10'
10'
20'
0'
10' 0' 10' 20'20'
0' 10'10' 20'20'
44 ft
27' 20' 12' 6' 3' 0 3' 6' 12' 20' 27' 30' 30' 20' 12' 6' 0 6' 12' 20' 30'
20' 18' 15' 12' 9' 6' 3' 0 3' 6' 9' 12' 15' 18' 20'
0'
27'
40' 50' 25' 0' 25' 50'
0'
50'
25'
25'
50'
100'
50' 40' 30' 20' 10' 0 10' 20' 30' 40' 50'
LLC wireless controller with #3 lens
Specifications
ECF-S_EcoForm_area_small 01/22 page 9 of 9
Area luminaire
Infrared Motion Response Lenses (IMRI3/IMRI7): Infrared Motion Response Integral module is available with two different sensor lens types to accommodate various mounting heights and occupancy detection ranges.
Lens #3 (IMRI3) is designed for mounting heights up to 20’ with a 40’ diameter coverage area. Lens #7 is designed for higher mounting heights up to 40’ with larger coverage areas up to 100’ diameter coverage area. See charts for approximate detection patterns:
Electrical Twist-Lock Receptacle (TLRD5/TLRD7/ TLRPC): Twist Lock Receptacle with 5 pins enabling dimming or with 7 pins with additional functionality (by others) can be used with a twistlock photoelectric cell or a shorting cap. Dimming Receptacle Type B (5-pin) and Type D-24 (7-pin) in accordance to ANSI C136.41. Can be used with third-party control system. Receptacle located on top of luminaire housing. When specifying receptacle with twistlock photoelectric cell, voltage must be specified. When ordering 7-pin Twist-lock receptacle (TLRD7), all 7 pins are wired to respective pins with the Sensor Ready (SR) driver, and photocell or shorting cap is not included. When ordering a twist-lock receptacle with a photocell (TLRPC), the receptacle used is a 5-pin receptacle, so pins 6 and 7 are not available (no SR driver).
0-10V dimming leads (pins 4 and 5) are connected if not ordered with any other dimming option.
Driver: Driver efficiency (>90% standard). 120-480V available (restrictions apply). Open/short circuit protection. All drivers are 0-10V dimming to 10% power standard, except when using Sensor Ready (SR) drivers, which uses DALI protocol (options CS50/CM50/CS30/CM30, SRDR, and TR7). Drivers are RoHS and FCC Title 47 CFR Part 15 compliant.
Button Photocontrol (PCB): Button style design for internal luminaires mounting applications. The photocontrol is constructed of a high impact UV stabilized polycarbonate housing. Rated voltage of 120V or 208-277V with a load rating of 1000 VA. The photocell will turn on with 1-4Fc of ambient light.
Surge protection (SP1/SP2): Surge protection device tested in accordance with ANSI/IEEE C62.45 per ANSI/IEEE C62.41.2 Scenario I Category C High Exposure 10kV/10kA waveforms for Line-Ground, Line-Neutral and Neutral- Ground, and in accordance with DOE MSSLC Model Specification for LED Roadway Luminaires Appendix D Electrical Immunity High test level 10kV/10kA.
20kV / 10kA surge protection device that provides extra protection beyond the SP1 10kV/10kA level.
Listings UL/cUL wet location listed to the UL 1598 standard, suitable for use in ambient temperatures from -40° to 40°C (-40° to 104°F). Most EcoForm configurations are qualified under Premium and Standard DesignLights Consortium® categories. Consult DLC Qualified Products list to confirm your specific luminaire selection is approved. CCTs 3000K and warmer are Dark Sky Approved.
Finish Each standard color luminaire receives a fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) textured polyester powdercoat finish. Standard colors include bronze (BZ), black (BK), white (WH), dark gray (DGY), and medium gray (MGY). Consult factory for specs on optional or custom colors.
Service Tag Each individual luminaire is uniquely identifiable, thanks to the Service tag application. With a simple scan of a QR code, placed on the inside of the mast door, you gain instant access to the luminaire configuration, making installation and maintenance operations faster and easier, no matter what stage of the luminaire’s lifetime. Just download the APP and register your product right away. For more details visit: signify.com
Warranty EcoForm luminaires feature a 5-year limited warranty See signify.com/warranties for complete details and exclusions.
Specifications
30' 27'
20'
12'
6' 3'
3' 6'
12'
20'
27'
30'
0' 60'
0'
10'
20'
30'
40'
0'
20'
10'
10'
20'
40' 10'
20'
0'
15'
5'
0'
8' 0' 3'3' 7'7' 11' '42'1124'
30'
20'
10'
10'
20'
0'
10' 0' 10' 20'20'
0' 10'10' 20'20'
44 ft
27' 20' 12' 6' 3' 0 3' 6' 12' 20' 27' 30' 30' 20' 12' 6' 0 6' 12' 20' 30'
20' 18' 15' 12' 9' 6' 3' 0 3' 6' 9' 12' 15' 18' 20'
0'
27'
40' 50' 25' 0' 25' 50'
0'
50'
25'
25'
50'
100'
50' 40' 30' 20' 10' 0 10' 20' 30' 40' 50'
IMRI3 Luminaire or remote mount controller with #3 lens
IMRI7 Luminaire or remote mount controller with #7 lens
30' 27'
20'
12'
6' 3'
3' 6'
12'
20'
27'
30'
0' 60'
0'
10'
20'
30'
40'
0'
20'
10'
10'
20'
40' 10'
20'
0'
15'
5'
0'
8' 0' 3'3' 7'7' 11' '42'1124'
30'
20'
10'
10'
20'
0'
10' 0' 10' 20'20'
0' 10'10' 20'20'
44 ft
27' 20' 12' 6' 3' 0 3' 6' 12' 20' 27' 30' 30' 20' 12' 6' 0 6' 12' 20' 30'
20' 18' 15' 12' 9' 6' 3' 0 3' 6' 9' 12' 15' 18' 20'
0'
27'
40' 50' 25' 0' 25' 50'
0'
50'
25'
25'
50'
100'
50' 40' 30' 20' 10' 0 10' 20' 30' 40' 50'
© 2021 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.
ECF-S_EcoForm_area_small 01/22 page 9 of 9
Signify North America Corporation 200 Franklin Square Drive, Somerset, NJ 08873 Telephone 855-486-2216
Signify Canada Ltd.
281 Hillmount Road, Markham, ON, Canada L6C 2S3 Telephone 800-668-9008
All trademarks are owned by Signify Holding or their respective owners.
www.gardcolighting.com
Buy American Act of 1933 (BAA):
This product is manufactured in one of our US factories and, as of the date of this document, this product was considered a commercially available off-the-shelf (COTS) item meeting the requirements of the BAA. This BAA designation hereunder does not address (i) the applicability of, or availability of a waiver under, the Trade Agreements Act, or (ii) the “Buy America” domestic content requirements imposed on states, localities, and other non-federal entities as a condition of receiving funds administered by the Department of Transportation or other federal agencies. Prior to ordering, please visit www.signify.com/baa to view a current list of BAA-compliant products to confirm this product’s current compliance.
http://www.signify.com/warranties http://www.signify.com/baa
| � | ��������������� | ||||
| ���������� | ��������� | ������������� | �� | ������ | �� |
| ���������� | ��������� | ��������� | �������� | ��� | ������� |
| ������ !""��#������ | ����� |
$%&'()*+,-.'/&01., 233'%445 6786�9� ���������:�;��<��= ��:�>��6?@8A
B..'31,&0%45 C?� D8"87C:�! A�787AC"A
EF%G&01.,5 ?8�
H1/%40&/I5 "8"C!68!6?�6AJC6J"8�86?K
L&M&'3*HNI%5 ;���
2$BE*OPQR
STU�68!V��
7<��
STU�"A!V��
STU�A8!V��
STU�688!V��
?D<��
T������ �=� ��U 68D<��
T������ �=�
��UU 66"<��
T������ �=�
��UUU 6""<��
T������ �=�
��UW 6"A<��
2$BE*OPQX
STU�68!V��
7<��
STU�"A!V��
@D<��
STU�A8!V��
?8<��
STU�688!V��
?7<��
T������ �=� ��U 68A<��
T������ �=�
��UU 66A<��
T������ �=�
��UUU!UW 6"8<��
2$BE*OPXY
����� !8A�;��������� ?8<��
Z[\]̂\_̀ab_]cdecfgb\e][\̂\]hi]jiZ]̂\ka\fb]gdl]_bgb\]m̂]amfga]gn\den\db_]bm]b[\]ogà\_]m̂]gdl]e\acd\gbcmd]acd\_]nge\]è ĉdp]b[\]q̀caecdp]fme\]gemrbcmd]r̂mf\__s]t_\̂_]_[m̀ae]fmdkĉn]gdl m̀br̀b]mqbgcd\e]k̂mn]b[c_]bmma]ucb[]b[\]amfga]v̀b[m̂cbl]wgocdp]x̀ ĉ_ecfbcmd]q\km̂\]r̂mf\\ecdp]ucb[]e\_cpds ya\g_\]dmb\]b[gb]b[\]vZz]wg{ĝe_]ql]|mfgbcmd]u\q_cb\]ucaa]dmb]q\]̀regb\e]bm]_̀rrm̂b]v}z~]����s]�cde]m̀b]u[ls
�14(F&1/%'
| ���� | � |
| ���� | ��� |
| �<��� | ��� |
| ���������� | �� | ������ |
| �� | ��������� | �=� |
| ������ :����������������� | ���� | |||
| ������ | ����� | ������ | ���� | �� |
| ������������ | �� |
| � | ������� | ���� | |||
| ����������<�������:� | ��������� | ��������� | |||
| ����� | ����� | � | ������ | ��������������� | �� |
| ����� | �� |
������J
| ���:� | ��� | ||
| ���� | ��=��� | � | |
| <��� | ������������ | ���� | �� |
| ��� | �� | ����������� |
| ��� | ������� | ����������!�� |
S��� ������� �
| <� | ����� | |||
| ���� | ������ | ��������� | �������������� | ������� |
| ����������� | ��� |
| �������� | �� |
| �� | ������ |
| ���������<� | � |
| ��� | ����� | ||
| �� | ������ | ||
| ���:���� | ����� | ����������������� | �������=���� |
| ���������������������� | ��� | ���� | �� | � | �������� |
| � | ������ |
| <� | ���� | |
| ������� | ������������=<�� | �� |
| ��������<�� | �� | �� |
| �� | ���:��� | |||
| � | ������ | � | � | �� |
| � | ��=������������=� | ��� |
| ���� | ��� | |
| � | ��� |
| �� | ||
| ���������� | ��������� | ������ |
| � | ����� | �� | �� |
| � | ��������� | ��������� | ��<������� |
| �������� | ���=��� |
| � | ����������=��� | ������ | |||
| ���������� | � | �������=� | �������� | ������� | ��� |
| � | ��������������� | ||||
| ���������� | ��������� | ������������� | �� | ������ | �� |
| ���������� | ��������� | ��������� | �������� | ��� | ������� |
| ������ !""��#������ | ����� |
$%&'()*+,-.'/&01., 233'%445 6786�9� ���������:�;��<��= ��:�>��6?@8A:�B��
C..'31,&0%45 D?� E8"87D:�! A�787AD"A
FG%H&01.,5 ?8�
I1/%40&/J5 "8"D!66!"@�"6KADKE7�"7 L
M&N&'3*IOJ%5 ����<��
P%-%'%,(%*Q.(R/%,05 ���� !67
P14S*C&0%T.'O5 U
$10%*CG&445 >
VCFP*M.'1N.,0&G*P%4J.,4%*$J%(0'R/ Q%41T,*M.'1N.,0&G*P%4J.,4%*$J%(0'R/
W&41(*X&'&/%0%'4
Y&/% Z&GR% Q%4('1J01.,
�� 8�6@ [��\�= ���̂8�"�_
�6 8�8E [��\�= ���̂6�8�_
�[� 8�"@@ �� �!<���
�[6 8�66" �� �!<���
�>� 8�6?" a�<� �������<�������=��̀������ �8�"����
�>6 8�8 A a�<� �������<�������=��̀������ �6�8���� b233101.,&G*+,-.'/&01., Y&/% Z&GR% Q%4('1J01., �>� c ����<�������=���� �=�
| #� 6�7 �� | ���<��� |
| ��� | ���� |
| �� | � |
| �� | �8�"� |
| #̀ "�E �� | ���<��� |
| ��� | ���� |
| �� | � |
| �� | �6�8� |
�\� 8�?A6 ���
����]8�"�_
�\6 8�?D@ ���
����]6�8�_
�d� 8�6 [��d������=
| #�d� 6�A?? �� | ���<��� |
| ��� | ���� |
| �� | � |
| �� | ��d� |
�d�[ 8�67 �� ��<���
�� 7 ���=!��
��\� 8�6@ �
| �������� | ��� |
| ���! | � |
| =� | ���= |
| �����<� | ����]8�"�_ |
��B� 8�6@? #�� �
| � | ����]"e�� |
| ������� | ��� |
�f������������A8����
| ��> 6�A #�� | � |
| ����� | � |
| <���� | ��������� |
| � | ����̀�����]8�"�_ |
�6\� 8�8E �
| �������� | ��� |
| ���! | � |
| =� | ���= |
| �����<� | ����]6�8�_ |
�6B� 8�8A #�� �
| � | ����]"e�� |
| ������� | ��� |
�f������������A8����
| �6> 8�7 #�� | � |
| ����� | � |
| <���� | ��������� |
| � | ����̀�����]6�8�_ |
ghijk lmnopmqmorstsuvwnxyqomozmnowyyxy
8�8 6�8 "�8 D�8 E�8 A�8 7�8 �8 X%'1.3*{4|
8�88
8�8A
8�68
8�6A
8�"8
8�"A
$&{T|
8�8 6�8 "�8 D�8 E�8 A�8 7�8 �8 X%'1.3*{4|
8�88
8�8A
8�68
8�6A
$&{T|
"ASCE710E.xls" Program
Version 2.1
SEISMIC FORCE FOR COMPONENTS
Per IBC 2012 and ASCE 7-10 Specifications
For Mechanical and Electrical Components
Job Name: VAMC Wilmington Subject: LIGHTPL SEIS. BASE SHEAR
Job Number: 20230236.00 (A720023236) Originator: WBCM Checker: WBCM
Input Data:
Risk Category = I IBC 2012, Table 1604.5
Soil Site Class = D IBC 2012 Table 1613.5.2
Location Zip Code = (not required)
Spectral Accel., SS = 0.180 ASCE 7-10 Figures 22-1 to 22-6
Spectral Accel., S1 = 0.047 ASCE 7-10 Figures 22-2 to 22-6
Average Roof Height, h = 25.000 ft.
Height of attachment, z = 25.000 ft.
Importance Factor, Ip = 1.00 ASCE 7-10 Section 13.1.3, page 113
Component Weight, Wp = 500.00 lbs., ASCE 7-10 Section 13.3.1, page 113
Component Type = 1k
Results:
Site Coefficients:
Fa = 1.600 IBC 2012 Table 1613.3.3(1)
Fv = 2.400 IBC 2012 Table 1613.3.3(2)
Maximum Spectral Response Accelerations for Short and 1-Second Periods:
SMS = 0.288 SMS = Fa*SS, IBC 2012 Eqn. 16-37
SM1 = 0.113 SM1 = Fv*S1, IBC 2012 Eqn. 16-38
Design Spectral Response Accelerations for Short and 1-Second Periods :
SDS = 0.192 SDS = 2*SMS/3, IBC 2012 Eqn. 16-39
SD1 = 0.075 SD1 = 2*SM1/3, IBC 2012 Eqn. 16-40
Seismic Design Category:
Category(for SDS) = IBC 2012 Table 1613.3.5(1)
Category(for SD1) = IBC 2012 Table 1613.3.5(2)
Use Category = D Most critical of either category case above controls
Amplification Factor and Response Modification Coefficient:
Amplification Factor, ap = 1.00 ASCE 7-10 Table 13.6-1, page 120
Response Mod. Coef., Rp = 1.50 ASCE 7-10 Table 13.6-1, page 120
Component Horizontal Seismic Force:
Fph = 76.80 lbs., Fph = (0.4*ap*SDS*Wp)*(1+2*z/h)/(Rp/Ip), Eqn. 13.3-1, page 113
Fph(max) = 153.60 lbs., Fph = 1.6*SDS*Ip*Wp, ASCE 7-10 Eqn. 13.3-2, page 113
Fph(min) = 28.80 lbs., Fph = 0.3*SDS*Ip*Wp, ASCE 7-10 Eqn. 13.3-3, page 113
Use: Fph = 76.80 lbs. Note: Fph is to be applied independently in both transverse and longitudinal directions relative to seismic restraint.
Component Vertical Seismic Force:
Fpv = 19.20 lbs., Fpv = 0.2*SDS*Wp, ASCE 7-10 Eqn. 12.4-4, page 86
Comments: VALMONT LIGHTPOLE
Lighting fixtures (ASCE 7-10 Table 13.6-1)
1 of 1 12/5/2023 8:00 AM
ASCE 7-16
ASCE 7-16
ASCE 7-16
IBC 2018
ASCE 7-16
ASCE 7-16
Rp = 1.5
IBC 2018 - ASCE 7-16 Specifications Electrical Components
IBC 2018
CONSERVATIVE
19805
IBC 2018 Table 1613.2.3(2) IBC 2018 Table 1613.2.3(1)
16-36 16-3716-37
IBC 2018
IBC 2018
16-38 16-39
IBC 2018
IBC 2018IBC 2018
ASCE 7-16 TABLE 11.6-1B
B ASCE 7-16 TABLE 11.6-2
CONSERVATIVE (B)
ASCE 7-16 TABLE 13.6-1
ASCE 7-16 TABLE 13.6-1
Pole Footing Embedded in Soil LIC# : KW-06015984, Build:20.23.04.05 WHITNEY BAILEY COX & MAGNANI (c) ENERCALC INC 1983-2023
DESCRIPTION: Light Pole Footing
Project File: VAMC Wilmington 2023.11.29.ec6
Project Title:
Engineer:
Project ID:
Printed: 5 DEC 2023, 9:28AM
Project Descr:
Code References Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16 Load Combinations Used : IBC 2021
General Information Circular
24.0
150.0 1,500.0
No Lateral Restraint at Ground Surface
Pole Footing Shape Pole Footing Diameter . . . . . . . . . . . in
Allow Passive . . . . . . . . . . . . . . . . . . . . . . pcf Max Passive . . . . . . . . . . . . . . . . . . . . . . psf
Calculate Min. Depth for Allowable Pressures
+D+0.60WGoverning Load Combination :
Lateral Load 0.2685 Moment 5.156 k-ft
Minimum Required Depth 5.625 ft k
NO Ground Surface Restraint
Pressures at 1/3 Depth Actual 274.105 psf Allowable 275.220 psf
Controlling Values ft^2Footing Base Area 3.142 Maximum Soil Pressure 0.1592 ksf k k k
0.50 k k
Applied Loads k
Lateral Concentrated Load (k)
D : Dead Load
L : Live Lr : Roof Live
S : Snow W : Wind E : Earthquake H : Lateral Earth Load distance above
0.240 0.0770
25.0 k k k k k k k ft
Lateral Distributed Loads (klf)
TOP of Load above ground surface
BOTTOM of Load above ground surface
0.00830
25.0 k/ft k/ft k/ft k/ft k/ft k/ft k/ft ftground surface ft
Vertical Load (k) k
Load Combination Results
Factor Soil IncreaseForces @ Ground Surface
Load Combination Required
Loads - (k) Moments - (ft-k) Depth - (ft) Pressure at 1/3 Depth
Allow - (psf)Actual - (psf)
0.00.000 0.000D Only 0.13 1.0000.0
274.10.269 5.156+D+0.60W 5.63 1.000275.2
168.20.054 1.348+D+0.70E 3.50 1.000169.5
247.30.201 3.867+D+0.450W 5.00 1.000248.4
152.60.040 1.011+D+0.5250E 3.13 1.000153.3
274.10.269 5.156+0.60D+0.60W 5.63 1.000275.2
168.20.054 1.348+0.60D+0.70E 3.50…