This document is an Addendum (No. 02) issued by alt32 Architecture | Design for the Commonwealth of Kentucky's Department for Facilities and Support Services, specifically for the Envelope Restoration project at the Ravenna Readiness Center for the Department of Military Affairs. The addendum, dated August 12, 2025, provides critical clarifications for bidders on RFB-35-26, including specific modifications to the original bid documents. Key changes include removing existing concrete stairs and landings, specifying new copper flashing requirements using Hohmann & Barnard's Copper-Fabric™ NA Copper Fabric Flashing, constructing window systems from storefront materials, and removing all references to ballistic and bullet resistance in favor of blast resistance.

The addendum also details storm water management requirements, mandating the installation of 8" schedule 40 PVC pipes below grade from six downspouts on the front and side of the building, with back-of-building downspouts discharging to an existing flume. Additionally, the document stipulates that no additional site visits are available prior to the bid date, and contractors must patch repair pavement with new blacktop that matches existing thicknesses. Bidders are instructed to acknowledge receipt of this addendum in their proposal and are governed by the information contained herein, which becomes part of the contract documents.

View the file

Other files

File Type Posted
Final_RFB_785_2600000036_3_SO_FORM.PDF PDF
Final_RFB_785_2600000036_2_SO_FORM.PDF PDF
Addendum One .pdf PDF
Final_RFB_785_2600000036_1_SO_FORM.PDF PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-35-26

FOR: Envelope Restoration Ravenna Readiness Center Department of Military Affairs Revenna, Kentucky

DATE: August 12, 2025

RFB-785-2600000036

ADDENDUM NO. Two (2)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.

END OF ADDENDUM

Invitation to Bid No. RFB-35-26 For: Envelope Restoration Ravenna Readiness Center Department of Military Affairs Revenna, Kentucky

Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration

ADDENDUM NO. 02

August 12, 2025

To: All Plan holders

From: alt32 Architecture | Design 310 Old Vine Street, Suite 300 Lexington, KY 40507-1534

Re: RFB-35-26 DMA Ravenna RC Envelop Restoration

This addendum is one (2) Page of 8-1/2 x 11.

The purpose of this addendum is to clarify further the requirements of the contract documents. The contractors are governed by the information in the addendum as the content becomes part of the contract documents. The bidders shall acknowledge receipt of the addendum in their form of proposal.

Items:

1. Additional Site Visits are not available prior to the Bid Date.

2. Clarification: Details 1/A5 and 2/A5 on sheet “A5 - CONCRETE STEPS ENLARGED PLAN / ELEVATIONS”, where it indicates that a portion of the existing concrete is to remain, disregard. Remove existing concrete stairs and landings complete. Provide new concrete stairs and landings. Ensure new concrete allows for flush condition at building entrances.

3. Clarification: Basis for Design for Laminated Copper Flashing is as follows:

Hohmann & Barnard’s Copper-Fabric™ NA Copper Fabric Flashing 7oz.

Reference drawing 1/A6, 9/A6, and 15/A6. Use at all locations where new flashing is required.

4. Clarification: Details 5/A6 and 6/A6 on Sheet A6; Window systems to be constructed and assembled out of storefront material.

5. Reference specification section 085653 Exterior Security Windows:

1.1 A. : Reference to “bullet” shall be stricken from the specifications.

1.5 - A – 1 and 5: Reference to UL 752 Ballistic shall be stricken from the specifications

2.3 F. : Reference to “bullet” shall be stricken from the specifications.

The design intent to is to delete all reference to ballistic and bullet resistance. The intent is for the designated windows and storefronts to conform to blast resistance.

6. Reference the previously published addendum 1. The design intent is the capture all storm water from the existing downspouts and pipe below grade to the existing culvert at the road. Thus:

Provide and install new 8” schedule 40 PVC pipe below grade from all downspouts on the front and side of the building - total 6. Provide new "boot" transition at the bottom of the downspouts to the new pipe.

Downspouts on the back of the building will discharge to the existing flume similar to existing.

Patch repair the pavement. with new blacktop patch. Match existing thickness(es)

End of Addendum