About this file

This document is an Addendum (No. 01) issued on August 11, 2025, by alt32 Architecture | Design for the Commonwealth of Kentucky's Department for Facilities and Support Services, specifically for the Envelope Restoration project at the Ravenna Readiness Center for the Department of Military Affairs. The addendum provides clarification and updates to the contract documents, with two primary modifications: the inclusion of a blast-resistant hardware schedule and updates to drawing Page G2 to add subsurface storm drainage. The project involves multiple exterior door sets, including blast-resistant hollow metal doors, single blast-resistant openings, and aluminum blast-resistant openings across five total door openings.

The hardware schedule details specific technical requirements for each door set, including continuous hinges, multi-point locksets, cores, closers, door sweeps, and thresholds. The doors are specified with blast-resistant characteristics, indicating a high-security or specialized military facility requirement. The addendum emphasizes that contractors must acknowledge receipt of these updates in their proposal, and the modifications become part of the binding contract documents. The specifications include precise measurements, door types (HMD Type HM-F x HMF Type HM-1), and specific hardware manufacturer codes and finishes, suggesting a detailed and technical procurement process.

View the file

Other files

File Type Posted
Final_RFB_785_2600000036_3_SO_FORM.PDF PDF
Final_RFB_785_2600000036_2_SO_FORM.PDF PDF
Addendum Two .pdf PDF
Final_RFB_785_2600000036_1_SO_FORM.PDF PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-35-26

FOR: Envelope Restoration Ravenna Readiness Center Department of Military Affairs Revenna, Kentucky

DATE: August 11, 2025

RFB-785-2600000036

ADDENDUM NO. One (1)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.

END OF ADDENDUM

Invitation to Bid No. RFB-35-26 For: Envelope Restoration Ravenna Readiness Center Department of Military Affairs Revenna, Kentucky

Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration

ADDENDUM NO. 01

August 11, 2025

To: All Plan holders

From: alt32 Architecture | Design 310 Old Vine Street, Suite 300 Lexington, KY 40507-1534

Re: 095-RCC0LA DMA Ravenna RC Envelope Restoration

This addendum is three (3) pages of 8-1/2 x 11 and (1) of 30 x 42

The purpose of this addendum is to clarify further the requirements of the contract documents. The contractors are governed by the information in the addendum as the content becomes part of the contract documents. The bidders shall acknowledge receipt of the addendum in their form of proposal.

Items:

1. Blast-Resistant Hardware Schedule A hardware schedule for blast-resistant openings is included with this addendum for reference and coordination with the specifications.

2. Updated Drawings - Page G2 Subsurface storm drainage has been added. The revised pages G2 supersede the corresponding sheet in the set of documents.

See attachments below

Hardware Sets

Set #01# - Exterior Blast Resistant Hollow Metal Doors

2 - 3' 0" x 7' 0" x 1 3/4" x HMD Type HM-F x HMF Type HM-1

Doors: 104, 105

2 Continuous Hinge 224HD 85" 628 IV 1 Blast Resistant Flush Bolts PER MANUFACTURER US28 WIKL

NOTE: Blast Resistant Door Manufacturer to provide Blast Resistant Flush Bolts 1 Mortise Multi-Point Lockset LMV9380BDC 07A 630 SC 1 Core 1CDM-6MJ11 626 BE 2 Closer 4040XP EDA AL LC 2 Door Sweep 39A 36" ZE 1 Threshold 566A 72" 223-MSLA-10 ZE

Number of Openings: 2

Set #02# - Exterior Single Blast Resistant Opening

3' 0" x 7' 0" x 1 3/4" x HMD Type HM-F x HMF Type HM-1

Doors: 102

1 Continuous Hinge 224HD 85" 628 IV 1 Mortise Multi-Point Lockset LMV9380BDC 07A 630 SC 1 Core 1CDM-6MJ11 626 BE 1 Closer 4040XP EDA AL LC 1 Door Sweep 39A 36" ZE

Number of Openings:

3' 6" x 7' 0" x 1 3/4" x HMD Type HM-F x HMF Type HM-1

Doors: 103

1 Continuous Hinge 224HD 85" 628 IV 1 Mortise Multi-Point Lockset LMV9380BDC 07A 630 SC 1 Core 1CDM-6MJ11 626 BE 1 Closer 4040XP EDA AL LC 1 Door Sweep 39A 42" ZE

Number of Openings:

Set #03# - Aluminum Blast Resistant Openings

Doors: 101

2 Continuous Hinge 224HD 85" 628 IV 1 Mullion MANUFACTURER SUPPLIED MULLION US28 WIKL oliver.hidalgo Cloud oliver.hidalgo Comments

ADDENDUM NO.1 - ITEM 1: HARDWARE SCHEDULE

Hardware Sets

Set #03# - Aluminum Blast Resistant Openings

NOTE: Manufacturer of the Aluminum Doors & Frame to supply the Blast Resistant Mullion, Prepped for the 3- Point latching Exit Devices

2 Exit Device 9957K-NL x 996K-NL-R&V US26D, US28

VO

2 Core 1C-7A2 622 BE01 2 Rim Cylinder 12E-72 L/C 626 BE 2 Closer 4040XP EDA AL LC

NOTE: All Weatherstrip, Threshold, and Glass to be supplied by the Aluminum Opening Supplier.

Number of Openings: 1

Total Number of Openings: 5 oliver.hidalgo Cloud oliver.hidalgo Comments

ADDENDUM NO.1 - ITEM 1: HARDWARE SCHEDULE

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X

X

X

X

X

COW C

REEK R

OAD

EXISTING CULVERT

EXISTING CULVERT

EXISTING HEADWALL INLET

EXISTING CONCRETE SPLASH BLOCK

SLOPED TOWARD BOTH ENDS - NO WORK

EXISTING

D.S

EXISTING

D.S

EXISTING

D.S

EXISTING

D.S

EXISTING

D.S

EXISTING

D.S

EXISTING

D.S

EXISTING

D.S

EXISTING

D.S

EXISTING

D.S

EXISTING CHAIN-LINK

FENCE - NO WORK

EXISTING HVAC UNIT. NO WORK

PROVIDE BOOT CONNECTIONS FOR STORM

PIPES AND DOWNSPOUTS. INSTALL 8"

SCHEDULE 40 PVC PIPE BELOW GRADE TO

EXISTING HEADWALL INLET

EXISTING

D.S

EXISTING EXTERIOR

CLEANOUT LOCATION -

PROTECT DURING

SUBSURFACE

DRAINAGE WORK

DRAWING NO.

AS BUILT DATE

DATEDESCRIPTION OF REVISIONS

REVISION HISTORY OF THIS DRAWING

ACCOUNT NO.

A & E FILE NO.

DRAWING INFORMATION

310 OLD VINE STREET, SUITE 300

LEXINGTON, KY 40507

T: 859.233.4804

PL

O

T

TI

M E:

PHASE

DRAWING DATE

DRAWN BY

CHECKED BY

PHASE

RTA DATE

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

COMMONWEALTH OF KENTUCKY

DESCRIPTION OF REVISIONS DATE

DECA LOG #

8/

/2

:0 0:

A

M

G2

DMA Ravenna RC Envelope Restoration

SITE PLAN

095-CCOL-RA04-00

RTA

7-21-2025

RTA

7-21-2025

OH / TD

MS / MB

1" = 20'-0"G2

1 SITE PLAN

ADDENDUM NO.1 - ITEM 2: STORM DRAINAGE 8/11/2025

Addendum One
Addendum 01 8.11.2025