COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-212-25
FOR: Bradley Hall Plumbing Upgrade Morehead Youth Development Center Department of Juvenile Justice Morehead, Kentucky
DATE: May 2, 2025
RFB-785-2500000584
ADDENDUM NO. Two (2)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
Item 2: Official Bid date has been moved to May 13, 2025, at 1:30 P.M. Eastern Time
END OF ADDENDUM
Invitation to Bid No. RFB-212-25 For: Bradley Hall Plumbing Upgrade Morehead Youth Development Center Department of Juvenile Justice Morehead, Kentucky
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
UP
UPDN
GENERAL NOTES:
A. REFER TO G SERIES DRAWINGS FOR ADDITIONAL GENERAL
NOTES AND INFORMATION.
B. REFER TO DRAWINGS OF ALL OTHER DISCIPLINES FOR
ADDITIONAL REMOVALS AND SELECTIVE DEMOLITION ACTIVITIES.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS
AND DIMENSIONS PRIOR TO SELECTIVE DEMOLITION ACTIVITIES.
D. CONTRACTOR SHALL REMOVE EXISTING ASBESTOS-CONTAINING
MATERIALS (ACM) WITHIN THE BUILDING.
E. EXISTING TO REMAIN ITEMS SHALL BE PROTECTED THROUGHOUT
THE DURATION OF THE PROJECT. IF ANY EXISTING ITEM IS
DAMAGED DURING CONSTRUCTION, IT SHALL BE REPLACED OR
RESTORED TO ITS ORIGINAL CONDITION.
F. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL TEMPORARY
SHORING AND BRACING REQUIRED TO COMPLETE THE WORK.
G. CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING AND PATCHING
REQUIRED, INCLUDING ASSOCIATED REPAIR AND FINISHING TO
MATCH ADJACENT SURFACES.
H. REMOVE ALL ABANDONED EQUIPMENT, DUCTWORK, PLUMBING,
ELECTRICAL, DATA, AND COMMUNICATIONS LINES, DEVICES, AND
EQUIPMENT. EXPOSED UTILITIES SHALL BE IDENTIFIED, CAPPED,
AND LABELED.
I. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY
ENVIRONMENTAL CONTROL MEASURES INCLUDING APPLICABLE
AIR QUALITY CONTROL MEASURES, DUST CONTROL, EROSION
CONTROL, AND OTHER MEASURES REQUIRED FOR PROTECTION
OF OCCUPANTS AND PROPERTY DURING SELECTIVE DEMOLITION
AND CONSTRUCTION ACTIVITIES.
J. CONTRACTOR IS SOLELY RESPONSIBLE FOR COORDINATING
CONTRACT DOCUMENTS WITH FIELD CONDITIONS AND WITH
WORK REQUIRED FOR EACH TRADE.
K. IN SPACES WHERE EXISTING CEILINGS ARE NOT BEING REMOVED,
CONTRACTOR SHALL TEMPORARILY REMOVE EXISTING CEILING
SYSTEM COMPONENTS AS REQUIRED TO INSTALL PIPING,
DUCTWORK, CONDUIT AND CABLING. CEILING SYSTEM
COMPONENTS SHALL BE REINSTALLED FOLLOWING WORK. ANY
DAMAGED CEILING COMPONENTS SHALL BE REPLACED TO
MATCH.
L. EXISTING CONCRETE SLAB-ON-GRADE SHALL BE SAWCUT AND
REMOVED AS REQUIRED TO COMPLETE UNDERGROUND PIPING
WORK. REPLACE CONCRETE SLAB-ON-GRADE AND FINISH TO
MATCH ADJACENT CONSTRUCTION. ALL CONCRETE REMOVAL
AND REPLACEMENT BEYOND THAT SHOWN IS INCIDENTAL TO THE
WORK AND SHALL BE INCLUDED IN THE CONTRACTOR'S BID AS
REQUIRED TO COMPLETE THE PROJECT.
M. BUILDING TO REMAIN PARTIALLY OCCUPIED DURING
CONSTRUCTION. SEQUENCE ALL DEMOLITION ACTIVITIES
ACCORDINGLY TO MINIMIZE DISRUPTION OF BUILDING
OCCUPANTS. REFER TO PHASING PLANS.
N. AT LOCATIONS WHERE PORTIONS OF EXISTING CMU WALLS ARE
BEING REMOVED TO ACCOMMODATE NEW
DOOR/LOUVER/WINDOW OPENINGS, CONTRACTOR SHALL
REMOVE AN ADDITIONAL 8-INCHES ON EACH SIDE OF THE
OPENING AND INSTALL A NEW BULLNOSE JAMB AND MASONRY
LINTEL AT THE OPENING. NEW OPENING TO BE TOOTHED INTO
EXISTING MASONRY COURSING.
O. CONTRACTOR SHALL COORDINATE DEMOLITION ACTIVITIES WITH
NEW WORK TO VERIFY DIMENSIONS AND EXTENT OF REMOVALS
PRIOR TO BEGINNING WORK.
P. IN CASES WHERE A PORTION OF AN EXISTING WALL IS BEING
REMOVED TO ACCOMMODATE NEW CONSTRUCTION, THE
CONTRACTOR MAY REMOVE ADDITIONAL ADJACENT WALL
CONSTRUCTION AND RECONSTRUCT THE BALANCE OF THE WALL
IF IT IS BENEFICIAL TO THE WORK, AT THE CONTRACTOR'S
OPTION AND EXPENSE. OBTAIN APPROVAL FROM ARCHITECT
PRIOR TO REMOVING MORE THAN WHAT IS INDICATED.
LEGEND:
EXISTING TO BE REMOVED
EXISTING FLOORING TO BE REMOVED
EXISTING TO REMAIN
OFFICE
OFFICE
OFFICE
ENTRY HALL
OFFICE
MECH
CORRIDOR
LIBRARY/VISITOR
CORRIDOR
CORRIDOR
ALCOVE
PSYCHIATRIST
OFFICE
NURSE
WAITING
EXAM
CORRIDOR
MEN
WOMEN
CLOSET
JAN
BATH
LINEN/JAN
OFFICE
WAITING
CORRIDOR
RECEPTION
CLOSET
FRONT
ENTRY
VESTIBULE
STAIR
ELEVATOR
HVAC
020908
020908 020908
020908
020908
020908
020908
020908
020908
020908
020908
020908
020908
020908
020908
020908
020909
020910
020910
020909020909020909020909020909
020909 020909
020909
020909
020909 020909
020909
020911
020910
MECH
CLOSET
127 020912
020912
020912
020910
LIBRARY/VISITOR
MECH
OFFICE
ENTRY HALL
OFFICE
OFFICE
OFFICE
CORRIDOR
CORRIDOR
EXAM
NURSE
PSYCHIATRIST
OFFICE
WAITING
CORRIDOR
CORRIDOR
ALCOVE
HVAC
VESTIBULE
ELEVATOR
STAIR
LINEN/JAN
BATH
OFFICE
RECEPTION
CORRIDOR
WAITING
WOMEN
MEN
CLOSET
118 JAN
MECH
CLOSET
BATH
022203
FRONT
ENTRY
135 020913
020913
020913
REFLECTED CEILING PLAN LEGEND
24"x24" SUSPENDED ACOUSTICAL PANEL
CEILING SYSTEM
SUSPENDED GYPSUM BOARD CEILING
(PAINTED)
RETURN AIR GRILLE, SEE MECHANICAL
SUPPLY AIR DIFFUSER, SEE MECHANICAL
LIGHT FIXTURE, SEE ELECTRICAL
LIGHT FIXTURE, SEE ELECTRICAL
EXHAUST GRILLE, SEE MECHANICAL
ACCESS PANEL
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
Addendum 1 04-24-2025
MARCH 10, 2025
HWS
ELM,YW
AD2.1
FIRST FLOOR REMOVAL FLOOR PLAN AND REFLECTED CEILING PLAN
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
KEYNOTES
020908 REMOVE AND REINSTALL EXISTING CEILING SYSTEM AS
REQUIRED TO INSTALL NEW WORK
020909 REMOVE PORTION OF EXISTING PLASTER CEILING
REQUIRED FOR NEW WORK
020910 REMOVE EXISTING GYPSUM BOARD CEILING COMPLETELY
020911 REMOVE EXISTING BULKHEAD COMPLETELY
020912 EXISTING GYPSUM CEILING TO REMAIN
020913 REMOVE PORTION OF WALL AS REQUIRED BY WORK
022203 REMOVE EXISTING WATER COOLER
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN REMOVAL
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN - REMOVAL
UP
UP
OFFICE
CLASSROOM
OFFICE
OFFICE
CLASSROOM
CLASSROOM
MECH
STORAGE
CLASROOM
MECH
STORAGE
CLASSROOM
MECH
MECH
STAIR
ELEVATOR
CLASSROOM
MECH
WORK
ROOM
CORRIDOR
VESTIBULE
STAFF
TOILET
205 TOILET
TOILET
A2.2
A2.2
A2.2
2/A3.1 2/A3.1 2/A3.1
220002
+- 2' - 0"
B
CLASSROOM
OFFICE
201 CLASSROOM
OFFICE
OFFICE
CLASSROOM
CLASSROOM
MECH
222CLASROOM
MECH
226 ELEVATOR
STAIR
VESTIBULE
CORRIDOR
CLASSROOM
STORAGE
WORK
ROOM
STORAGE
MECH
MECH
MECH
8' - 6"
8' - 0"
8' - 6"
TOILET
TOILET
STAFF
TOILET
8' - 0"
8' - 0"
8' - 6"
6' - 11"
8' - 6" 8' - 6"
8' - 6" 8' - 0"
8' - 6"
8' - 6"
8' - 0"
095103 095103 095103 095103095103
NO WORK
NO WORK
NO WORK
NO WORK
NO WORK
NO WORK
NO WORK
NO WORK
NO WORK
NO WORK
NO WORK
10" 4' - 6 3/8" 5' - 3 3/4"
A2.2
10' - 8 1/8" F.V.
TOILET
CLASSROOM
OFFICE
CORRIDOR
MECH
C
102830
102810
102833
102831 102803
102830
102804
220001
C B A
A
(TYP.)
093061
TOILET
CLASSROOM
OFFICE
CORRIDOR
220001
102831
102804
102830
102803
102833
102830
102810
MECH
A2.2
4' - 10" 5' - 0" 10 3/4" F.V.
10' - 8 3/4" F.V.
C
A
A L
IG
N N
E W
F
IN
IS
H
E S
W
IT
H
E X
IS
T
IN
G
AD-1
D
A
B
C
A
/4
OFFICE
MECH
STAFF
TOILET
CLASSROOM
B
A L
IG
N
A L
IG
N
B
A
9" 3' - 4" 3' - 11 1/2"
F .V
/8
2' - 5 1/2"
ALIGN
205A2.2
S
IM
SECOND FLOOR
110' - 6"
220001
102803
102804
102830
102831
102833
102836
102820
102810
1' - 5" 1' - 8" 1' - 5"
083101
AD-1
102836
093061
SECOND FLOOR
110' - 6"
102833
102830
102803
220001
102810
093061
2' - 0"
102804
102831
SECOND FLOOR
110' - 6"
083101
102831
102830
102804
220001
AD-1
093061
SECOND FLOOR
110' - 6"
102810
093061
220001
102820
102836
1' - 8" 1' - 9 3/4"
OFFICE
RB
STAFF
TOILET
PTB
MECH
CLASSROOM
RB TOILET
PTB
OFFICE
RB
OFFICE
RB TOILET
PTB
CLASSROOM
RB
MECH
MECH
CORRIDOR
WORK
ROOM
CLASSROOM
CLASSROOM
CLASROOM
CLASSROOM
MECH
STORAGE
RB
STORAGE
RB
MECH
VESTIBULE
ELEVATOR
STAIR
FINISH LEGEND
LVT - COLLECTION: HOT & HEAVY II
BOLDER 5.0
COLOR: 859 AURA
PATTERN: BRICK ASHLER
PTF - SERIES: CHICAGO
COLOR: STEEL
PATTERN: 12"X12" MOSAIC
VCT - COLLECTION: VCT II
COLOR: 569 EBONY B
REFLECTED CEILING PLAN LEGEND
24"x24" SUSPENDED ACOUSTICAL PANEL
CEILING SYSTEM
SUSPENDED GYPSUM BOARD CEILING
(PAINTED)
RETURN AIR GRILLE, SEE MECHANICAL
SUPPLY AIR DIFFUSER, SEE MECHANICAL
LIGHT FIXTURE, SEE ELECTRICAL
LIGHT FIXTURE, SEE ELECTRICAL
EXHAUST GRILLE, SEE MECHANICAL
ACCESS PANEL
GENERAL NOTES:
A. REFER TO G1.1 FOR ADDITIONAL GENERAL NOTES AND
INFORMATION.
B. REFER TO SHEET G1.3 FOR STANDARD ADA MOUNTING
HEIGHTS OF ALL FIXTURES, ACCESSORIES, AND SIGNAGE.
C. GYPSUM BOARD CEILINGS LOCATED IN TOILET ROOMS AND
LOCKER ROOMS SHALL BE MOLD- AND MOISTURE-
RESISTANT TYPE.
D. EXPOSED STRUCTURAL STEEL, METAL DECK, AND PRE-
CAST CONCRETE SHALL BE PAINTED.
E. EXPOSED DUCTWORK, PIPING AND CONDUIT SHALL BE
PAINTED.
F. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING WORK.
NORTH
SCALE: 1/8" = 1'-0"
SECOND FLOOR REFLECTED CEILING PLAN
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
NOTE:
ELEMENTS ON THIS DRAWING ARE IDENTIFIED BY VARIOUS
COLORS. IF THIS NOTE IS NOT RED, THIS DRAWING IS NOT IN
COLOR AND NEEDS TO BE REPRINTED IN COLOR.
Addendum 1 04-24-2025
MARCH 10, 2025
HWS
ELM,YW
A2.2
SECOND FLOOR PLAN AND REFLECTED CEILING PLAN
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
KEYNOTES
083101 LOCKABLE 2'-0"X2'-0" WALL-MOUNTED ACCESS PANEL,
TYPE AD-1
093061 GLAZED CERAMIC WALL TILE, COLOR ACRTIC WHITE
095103 REINSTALL ACT CEILING
102803 SURFACE MOUNTED ROLL TOILET TISSUE DISPENSER
102804 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL UNIT
102810 SURFACE MOUNTED PAPER TOWEL DISPENSER,
OWNER FURNISHED OWNER INSTALLED
102820 WALL MOUNTED SOAP DISPENSER, OWNER FURNISHED
OWNER INSTALLED
102830 42" GRAB BAR
102831 36" GRAB BAR
102833 18" GRAB BAR
102836 24"x36" MIRROR UNIT
220001 PLUMBING EQUIPMENT, REFERENCE PLUMBING
220002 WATER COOLER
NORTH
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLAN
NORTH
SCALE: 1/4" = 1'-0"
TOILET 217 ENLARGED PLAN
NORTH
SCALE: 1/4" = 1'-0"
TOILET 211 ENLARGED PLAN
NORTH
SCALE: 1/4" = 1'-0"
TOILET 205 ENLARGED PLAN
SCALE: 3/8" = 1'-0"
TOILET 205 & 211 ELEVATION
SCALE: 3/8" = 1'-0"
TOILET 217 ELEVATION
SCALE: 3/8" = 1'-0"
TOILET 217 ELEVATION
SCALE: 3/8" = 1'-0"
TOILET 217 ELEVATION
NORTH
SCALE: 1/8" = 1'-0"
SECOND FLOOR FINISH PLAN
FINISH ABBREVIATIONS:
ACT ACOUSTIC CEILING TILE
CMU CONCRETE MASONRY UNIT
CPT CARPET TILE
GWB-1 GYPSUM WALL BOARD
GWB-2 MOISTURE RESISTANT GYPSUM WALL BOARD
PT-1 PAINT, COLOR 1
PTB PORCELAIN TILE BASE
PTF PORCELAIN TILE FLOOR
PTW PORCELAIN TILE WALL
VCT VINYL COMPOSITION TILE
LVT LUXURY VINYL TILE
WALL TYPE - A
ACTUAL DIM.
NOTE: PROVIDE APPROPRIATE FIRESTOPPING SYSTEM AT ALL THRU-WALL
PENETRATIONS/OPENINGS FOR RATED WALL AND FLOOR ASSEMBLIES.PARTITION SCHEDULE
3 5/8" METAL STUDS
@ 16" OC
5/8" GYPSUM
BOARD
ACTUAL DIM.
3 5/8" METAL STUDS
@ 16" OC
5/8" GYPSUM BOARD
BOTH SIDES
4 7/8" 4 1/4"
WALL TYPE - B
• TAKE TO UNDERSIDE OF STRUCTURE• TAKE TO UNDERSIDE OF STRUCTURE
WALL TYPE - C
ACTUAL DIM.
3 5/8" METAL STUDS
@ 16" OC
5/8" GYPSUM BOARD
4 7/8"
• TAKE TO UNDERSIDE OF STRUCTURE
• TILE 7'-0" A.F.F.
5/8" BACKER BOARD
PORCELAIN TILE
WALL TYPE - D
ACTUAL DIM.
3 5/8" METAL STUDS
@ 16" OC
4 5/8"
• TAKE TO UNDERSIDE OF STRUCTURE
• TILE 7'-0" A.F.F.
5/8" BACKER BOARD
PORCELAIN TILE
SOUND ATTENUATION
BATT INSULATION
SOUND ATTENUATION
BATT INSULATION
SOUND ATTENUATION
BATT INSULATION
SOUND ATTENUATION
BATT INSULATION
GENERAL NOTES:
REFER TO G1.1 FOR ADDITIONAL GENERAL NOTES AND
INFORMATION.
PROVIDE APPROPRIATE FIRESTOPPING SYSTEM AT ALL THRU-
WALL PENETRATIONS/OPENINGS FOR RATED WALLS AND
ASSEMBLIES.
REFERENCE FLOOR PLANS FOR LOCATION OF PARTITION TYPE.
REFER TO STRUCTURAL DRAWINGS FOR APPLICABLE WALL
REINFORCEMENT AND ADDITIONAL REQUIREMENTS.
ALL HOLLOW METAL DOORS AND FRAMES ARE TO BE PAINTED.
COORDINATE DOORS WITH ACCESS CONTROL HARDWARE
WITH ELECTRICAL REQUIREMENTS. CONTRACTOR IS
RESPONSIBLE TO PROVIDE ALL WIRING, CONNECTIONS, AND
INITIAL PROGRAMMING AND TRAINING FOR ACCESS CONTROL
SYSTEMS, INCLUDING SOFTWARE AND DEVICES REQUIRED FOR
PROGRAMMING ACCESS CONTROL SYSTEM.
PROVIDE A ROOM IDENTIFICATION PANEL SIGN FOR EACH
INTERIOR DOOR LOCATION, INCLUDING MALE/FEMALE/UNISEX
AND ADA GRAPHICS WHERE APPLICABLE. FINAL ROOM NAMES,
ROOM NUMBERS, AND LOCATIONS TO BE DETERMINED PRIOR
TO FABRICATION. MOUNTING FOR PANEL SIGNS TO BE ON THE
WALL ADJACENT TO THE DOOR APPROXIMATELY 48"-54" A.F.F.
REFER TO PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS.
A.
B.
C.
D.
E.
F.
G.
H.
AS SCHEDULED
A S
S C
H E
D U
L E
D
DOOR ELEVATION
A
AS SCHEDULED
A S
S C
H E
D U
L E
D
FRAME ELEVATION
2"2"
SEALANT FULL PERIMETER BOTH
SIDES, TYP.
FLUSH WOOD DOOR, REFER TO DOOR
AND FRAME SCHEDULE
EXISTING WALL CONSTRUCTION
M.E. 5 3/4"
HOLLOW METAL FRAME, GROUT SOLID
5/8" 3 5/8" 5/8"
4 7/8"
5/8" GYPSUM WALLBOARD
6" METAL STUDS AT 16" O.C.
SOUND ATTENUATION BATT
INSULATION
SEALANT FULL PERIMETER BOTH
SIDES, TYP.
HOLLOW METAL FRAME
FLUSH WOOD DOOR, REFER TO DOOR
AND FRAME SCHEDULE
SEALANT FULL PERIMETER BOTH
SIDES, TYP.
FLUSH WOOD DOOR, REFER TO DOOR
AND FRAME SCHEDULE
5 7/8"
5/8" 3 5/8" 5/8"
4 7/8"
5/8" GYPSUM WALLBOARD
6" METAL STUDS AT 16" O.C.
SOUND ATTENUATION BATT
INSULATION
HOLLOW METAL FRAME
SEALANT FULL PERIMETER BOTH
SIDES, TYP.
FLUSH WOOD DOOR, REFER TO DOOR
AND FRAME SCHEDULE
EXISTING WALL CONSTRUCTION
M.E. 5 3/4"
HOLLOW METAL FRAME, GROUT SOLID
REMOVE WALL TILE COMPLETELY,
PATCH PLASTER WALL
REMOVE EXISTING PAPER TOWEL
DISPENSER AND RETURN TO OWNER
REMOVE EXISTING MIRROR AND
ACCESSORIES COMPLETELY, RETURN
TO OWNER
REMARKS:
1. 1" UNDERCUT.
2. EXISTING FRAME TO REMAIN. PROVIDE
CONTINUOUS HINGE.
3. MATCH EXISTING DOOR SIZE.
ACOUSTICAL TILE CEILING,
REFERENCE REFLECTED CEILING
PLAN
AXIOM TRANSITION
T-BAR CONNECTOR TWIST CLIP
ACOUSTICAL TILE CEILING,
REFERENCE REFLECTED CEILING
PLAN
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
NOTE:
ELEMENTS ON THIS DRAWING ARE IDENTIFIED BY VARIOUS
COLORS. IF THIS NOTE IS NOT RED, THIS DRAWING IS NOT IN
COLOR AND NEEDS TO BE REPRINTED IN COLOR.
Addendum 1 04-24-2025
MARCH 10, 2025
HWS
ELM,YW
A3.1
ROOM FINISH, PARTITION & DOOR SCHEDULES
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
ROOM FINISH SCHEDULE
ROOM
NO. ROOM NAME
FLOORS WALLS CEILING
MAT. BASE
NORTH EAST SOUTH WEST
MAT. FINISHMAT. FINISH MAT. FINISH MAT. FINISH MAT. FINISH
101 CORRIDOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
102 ENTRY HALL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
103 CORRIDOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
114 OFFICE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
116 LINEN/JAN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
117 BATH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
120 MEN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
121 WOMEN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
123 EXAM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
124 NURSE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
126 OFFICE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
129 BATH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
130 OFFICE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
131 OFFICE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
132 OFFICE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
133 MECH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
134 LIBRARY/VISITOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
201 OFFICE LVT RB - - - PT-1 - - - PT-1 - - - PT-1 - - - PT-1 ACT - - -
205 STAFF TOILET PTF PTB - - - PTW - - - PTW - - - PTW - - - PTW GWB PT-1
206 CLASSROOM LVT RB - - - PT-1 - - - PT-1 - - - PT-1 - - - PT-1 ACT - - -
211 TOILET PTF PTB - - - PTW - - - PTW - - - PTW - - - PTW GWB PT-1
212 OFFICE LVT RB - - - PT-1 - - - PT-1 - - - PT-1 - - - PT-1 ACT - - -
213 OFFICE LVT RB - - - PT-1 - - - PT-1 - - - PT-1 - - - PT-1 ACT - - -
217 TOILET PTF PTB - - - PTW - - - PTW - - - PTW - - - PTW GWB PT-1
218 CLASSROOM LVT RB - - - PT-1 - - - PT-1 - - - PT-1 - - - PT-1 ACT - - -
221 STORAGE VCT RB - - - PT-1 - - - PT-1 - - - PT-1 - - - PT-1 ACT - - -
225 CLASROOM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
227 STORAGE VCT RB - - - PT-1 - - - PT-1 - - - PT-1 - - - PT-1 ACT - - -
236 CLASSROOM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
238 WORK ROOM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ACT - - -
DOOR AND FRAME SCHEDULE
OPNG.
NO.
DOOR FRAME FRAME
LABEL/
HOUR
DETAILS
OPNG.
NO.
REMARKS
WIDTH HEIGHT ELEV. MAT'L
GLAZING
TYPE ELEV. MAT'L DEPTH
GLAZING
TYPE HEAD JAMB SILL
205 3' - 0" 7' - 0" A WD - - - 1 HM 5 7/8" - - - - - - H2 J2 - - - 205 1.
211 3' - 0" 7' - 0" A WD - - - - - - - - - - - - - - - 60 - - - - - - - - - 211 2., 3.
217 3' - 0" 7' - 0" A WD - - - 1 HM 5 3/4" - - - 60 H1 J1 - - - 217
218 3' - 0" 7' - 0" A WD - - - 1 HM 5 3/4" - - - 60 H1 J1 - - - 218
SCALE: 1 1/2" = 1'-0"
H1
HEAD DETAIL - EXISTING WALL
SCALE: 1 1/2" = 1'-0"
H2
HEAD DETAIL - STUD WALL
SCALE: 1 1/2" = 1'-0"
J2
JAMB DETAIL - STUD WALL
SCALE: 1 1/2" = 1'-0"
J1
JAMB DETAIL - EXISTING WALL
SCALE: 12" = 1'-0"
BATHROOM IMAGE
SCALE: 1 1/2" = 1'-0"
ACOUSTICAL TO ACOUSTICAL TRANSISTION
GENERAL NOTES
A. REFER TO SHEETS G1.1 AND P0.1 FOR ADDITIONAL GENERAL
NOTES AND INFORMATION.
B. WHERE PIPE SIZES MAY NOT BE INDICATED SERVING A FIXTURE,
PROVIDE SIZES AS INDICATED IN THE PLUMBING FIXTURE
SCHEDULE.
C. INSTALL ALL EQUIPMENT, FIXTURES AND ASSOCIATED
ACCESSORIES AS PER MANUFACTURER'S RECOMMENDATIONS.
D. COORDINATE WITH ALL OTHER DISCIPLINES BEFORE INSTALLING
ANY PIPING DEVICES.
E. EXACT LOCATION OF PLUMBING FIXTURES SHALL BE
COORDINATED WITH ARCHITECTURAL PLANS TO MEET ADA
REQUIREMENTS.
F. SANITARY PIPING GREATER THAN 3" IN DIAMETER SHALL BE
SLOPPED AT 1/8" PER FOOT. SANITARY PIPING 3" OR LESS IN
DIAMETER SHALL BE SLOPPED AT 1/4" PER FOOT.
G. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
CONDITION OF EXISTING SANITARY PIPING (TO WHICH NEW
SANITARY PIPING IS CONNECTED). IF THE CONDITION IS NOT
ACCEPTABLE, CONTRACTOR SHALL BE RESPONSIBLE FOR
REPLACING OF PIPING.
H. PRIOR TO INSTALLATION AND POST INSTALLATION CONTRACTOR
SHALL BE RESPONSIBLE FOR CLEANING AND UNCLOGGING OF
EXISTING SANITARY LINES OF ANY BLOCKAGE OR DEBRIS.
022201
022201
022201
022201 022201
RECEPTION
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
ENTRY HALL
CORRIDOR
CORRIDOR
PSYCHIATRIST
OFFICE
NURSE
EXAM
WAITING
MECH
LIBRARY/VISITOR
CORRIDOR
ALCOVE
HVAC
VESTIBULE
ELEVATOR
STAIR
CLOSET
JAN
MEN
WOMEN
LINEN/JAN
BATH
OFFICE
CLOSET
WAITING
CORRIDOR
DINING
ROOM
CLOSET
MECH
FRONT
ENTRY
ENTRY HALL
DRY
STORAGE
KITCHEN
WARE WASH
AREA
140OFFICE
BATH
JAN
VEST
2" V-TFA
4" SAN-FFA
022208
022201
022201
SAN SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
S A
N
EX-V
X-WC-1
X-L-1
X-UR-1
X-WC-1 X-L-1
X-L-1
X-WC-1
2" V
4" SAN
022209
022209
2" V
2" V-TFA
KEYNOTES
022201 DEMO SANITARY PIPING BACK TO SANITARY RISER.
PATCH RISER AS NEEDED FOR NEW CONSTRUCTION
CONNECTIONS.
022208 EXISTING WATER COOLER TO BE REMOVED.
TEMPORARILY CAP OFF SANITARY, VENT, AND
DOMESTIC LINES FOR FUTURE INSTALLATION.
022209 SANITARY RISER SERVING WORK ROOM SINK TO
REMAIN IN WALL FOR NEW SANITARY CONNECTION.
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
ADDENDUM 1 04-24-2025
MARCH 10, 2025
SSB
JMC
PD2.0
FIRST FLOOR SANITARY & VENT PLUMBING REMOVAL PLAN
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR SANITARY & VENT PLUMBING
REMOVAL PLAN
NOTES AND INFORMATION.
B. WHERE PIPE SIZES MAY NOT BE INDICATED SERVING A FIXTURE,
PROVIDE SIZES AS INDICATED IN THE PLUMBING FIXTURE
SCHEDULE.
C. INSTALL ALL EQUIPMENT, FIXTURES AND ASSOCIATED
ACCESSORIES AS PER MANUFACTURER'S RECOMMENDATIONS.
D. COORDINATE WITH ALL OTHER DISCIPLINES BEFORE INSTALLING
ANY PIPING DEVICES.
E. EXACT LOCATION OF PLUMBING FIXTURES SHALL BE
COORDINATED WITH ARCHITECTURAL PLANS TO MEET ADA
REQUIREMENTS.
F. SANITARY PIPING GREATER THAN 3" IN DIAMETER SHALL BE
SLOPPED AT 1/8" PER FOOT. SANITARY PIPING 3" OR LESS IN
DIAMETER SHALL BE SLOPPED AT 1/4" PER FOOT.
G. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
CONDITION OF EXISTING SANITARY PIPING (TO WHICH NEW
SANITARY PIPING IS CONNECTED). IF THE CONDITION IS NOT
ACCEPTABLE, CONTRACTOR SHALL BE RESPONSIBLE FOR
REPLACING OF PIPING.
H. PRIOR TO INSTALLATION AND POST INSTALLATION CONTRACTOR
SHALL BE RESPONSIBLE FOR CLEANING AND UNCLOGGING OF
EXISTING SANITARY LINES OF ANY BLOCKAGE OR DEBRIS.
RECEPTION
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
ENTRY HALL
CORRIDOR
CORRIDOR
PSYCHIATRIST
OFFICE
NURSE
124EXAM
WAITING
MECH
LIBRARY/VISITOR
CORRIDOR
ALCOVE
HVAC
VESTIBULE
ELEVATOR
STAIR
CLOSET
JAN
MEN
WOMEN
LINEN/JAN
BATH
OFFICE
CLOSET
WAITING
CORRIDOR
DINING
ROOM
CLOSET
MECH
FRONT
ENTRY
ENTRY HALL
DRY
STORAGE
KITCHEN
WARE WASH
AREA
140OFFICE
BATH
JAN
VEST
X-WC-1
X-L-1
X-UR-1
X-WC-1
X-WC-1
X-L-1
X-L-1
X-L-1
X-WC-1
EWC-1
4" SAN
3" SAN
3" SAN-FFA
3" SAN-FFA
2" SAN-FFA
X-B-1
2" SAN
4" SAN-TFB
4" SAN-FFA
2" SAN-FFA
4" SAN-FFA
2" V-TFA
EX-2" V
224701
4" SAN-TFB
221304
221304
221305
221305
2" V-TFA
221306
3" SAN-FFA
2" SAN-FFA
2" SAN
3" SAN
4" SAN-FFA
2" V-TFA
4" SAN
EX-2" V
EX-2" V
EX-4" SAN
2" V-TFA
221304
4" SAN-FFA
4" SAN
4" SAN
2" V
4" SAN-FFA
2" SAN-FFA
3" SAN-FFA
4" SAN-FFA
2" V-TFA
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
ADDENDUM 1 04-24-2025
MARCH 10, 2025
SSB
JMC
P2.0
FIRST FLOOR SANITARY & VENT INSTALLATION PLAN
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
KEYNOTES
221304 CONNECT NEW SANITARY PIPING INTO EXISTING RISER.
221305 SANITARY LINE LOCATED IN CEILING SPACE TO SERVE
PLUMBING FIXTURES ON FLOOR ABOVE.
221306 COORDINATE SANITARY PIPE ROUTING TO REMAIN CLEAR
OFF ANY ELECTRICAL EQUIPMENT IN SPACE.
224701 INSTALL NEW ELECTRIC WATER COOLER IN PLACE OF
EXISTING. RECONNECT TO EXISTING DOMESTIC AND
SANITARY PIPING IN THE SPACE.
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR SANITARY & VENT PLUMBING
INSTALLATION PLAN
NOTES AND INFORMATION.
B. WHERE PIPE SIZES MAY NOT BE INDICATED SERVING A FIXTURE,
PROVIDE SIZES AS INDICATED IN THE PLUMBING FIXTURE
SCHEDULE.
C. INSTALL ALL EQUIPMENT, FIXTURES AND ASSOCIATED
ACCESSORIES AS PER MANUFACTURER'S RECOMMENDATIONS.
D. COORDINATE WITH ALL OTHER DISCIPLINES BEFORE INSTALLING
ANY PIPING DEVICES.
E. EXACT LOCATION OF PLUMBING FIXTURES SHALL BE
COORDINATED WITH ARCHITECTURAL PLANS TO MEET ADA
REQUIREMENTS.
F. SANITARY PIPING GREATER THAN 3" IN DIAMETER SHALL BE
SLOPPED AT 1/8" PER FOOT. SANITARY PIPING 3" OR LESS IN
DIAMETER SHALL BE SLOPPED AT 1/4" PER FOOT.
G. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
CONDITION OF EXISTING SANITARY PIPING (TO WHICH NEW
SANITARY PIPING IS CONNECTED). IF THE CONDITION IS NOT
ACCEPTABLE, CONTRACTOR SHALL BE RESPONSIBLE FOR
REPLACING OF PIPING.
H. PRIOR TO INSTALLATION AND POST INSTALLATION CONTRACTOR
SHALL BE RESPONSIBLE FOR CLEANING AND UNCLOGGING OF
EXISTING SANITARY LINES OF ANY BLOCKAGE OR DEBRIS.
RECEPTION
OFFICE
126 OFFICE
OFFICE
OFFICE
CORRIDOR
ENTRY HALL
CORRIDOR
CORRIDOR
PSYCHIATRIST
OFFICE
NURSE
EXAM
WAITING
MECH
LIBRARY/VISITOR
CORRIDOR
ALCOVE
HVAC
VESTIBULE
ELEVATOR
STAIR
CLOSET
JAN
MEN
WOMEN
LINEN/JAN
BATH
OFFICE
CLOSET
WAITING
CORRIDOR
DINING
ROOM
CLOSET
MECH
FRONT
ENTRY
ENTRY HALL
DRY
STORAGE
KITCHEN
WARE WASH
AREA
140OFFICE
BATH
JAN
VEST
221103
X-WC-1
X-L-1
X-UR-1
X-WC-1
X-WC-1
X-L-1
X-L-1
X-L-1
X-WC-1
EWC-1
EX-1 1/2" DCW
EX-1/2" DHWR
EX-3/4" DHW
1" DCW
EX-1/2" DHWR
EX-3/4" DHW
EX-1 1/2" DCW
1 1/2" DCW
3/4" DHW
X-B-1
EX-1 1/2" DCW
EX-3/4" DHW
EX-3/4" DCW
EX-3/4" DHW
1" DCW-TFA
224701
3/4" DHW-TFA
3/4" DCW-TFA
3/4" DCW-TFA
3/4" DHW-TFA
3/4" DCW-TFA
3/4" DHW-TFA
3/4" DHW
1/2" DHWR
1 1/2" DCW-TFA
3/4" DCW-TFA
3/4" DHW-TFA
1/2" DHWR-FFA
1/2" DHWR
WHA-A
221103
221109
221109
EX-1/2" DHWR
EX-1 1/2" DCW
EX-3/4" DHW
1" DHW
2" DCW
1/2" DHWR
2" DCW
1" DHW
1" DHW-FFB
2" DCW-FFB
1/2" DHWR-TFB
1 1/2" DCW
3/4" DCW-TFA
3/4" DHW-TFA
1 1/2" DCW-TFA
OFFICE
CLASSROOM
OFFICE
OFFICE
CLASSROOM
CORRIDOR
CLASSROOM
MECH
STORAGE
CLASROOM
MECH
STORAGE
CLASSROOM
MECH
MECH
STAIR
ELEVATOR
CLASSROOM
WORK
ROOM
MECH
VESTIBULE
STAFF
TOILET
TOILET
TOILET
WC-1
L-1
X-S-1
X-S-2
EWC-1
FD-1
FD-1
221104
EX-4" V
1 1/2" V
1" DCW
EX-3/4" DCW
EX-2" V
EX-3/4" DHW
EX-3/4" DCW
EX-3/4" DHW
EX-3/4" DCW
WCO-1
WHA-A
WHA-A
WHA-A
WHA-A
WHA-A
2" V
1 1/2" DCW
2" V
1 1/2" V
3/4" DCW
3/4" DHW
4" V-VTR
4" V-VTR
221104
4" SAN
WCO-1
P2.1
3" V
WHA-A
L-1
WC-1
3/4" DHW-FFB
1 1/2" DCW-FFB
WCO-1
WC-1
FD-1
L-1
1 1/2" V
2" V
4" SAN
1 1/2" V
1 1/2" DCW
3/4" DHW
4" V
1/2" DHWR 221107 221109
221111
221109
221110
221104
WHA-A
WHA-A
WHA-B
WHA-B
1 1/2" DCW
3/4" DCW
3/4" DHW
1/2" DHWR
TOILET
MECH
CLASSROOM
OFFICE
1/2" DHWR
3/4" DHW
1 1/2" DCW
EX-1/2" DHWR
EX-3/4" DHW
EX-1 1/2" DCW
CORRIDOR
1/2" DHWR
3/4" DHW
3/4" DCW
NORTH
SCALE: 1/8" = 1'-0"
SECOND FLOOR OVERALL PLUMBING INSTALLATION
PLAN
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
ADDENDUM 1 04-24-2025
MARCH 10, 2025
SSB
JMC
P2.1
DOMESTIC INSTALLATION PLAN
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
KEYNOTES
221103 SHUTOFF VALVE DEDICATED TO PLUMBING FIXTURE
LOCATED ABOVE TO BE PROVIDED IN ACCESSIBLE CEILING.
221104 CONNECT NEW PIPING TO EXISTING VENT THRU ROOF.
221107 SHUTOFF VALVE'S ON DOMESTIC COLD WATER, HOT
WATER, AND HOT WATER RETURN PIPING DEDICATED TO
PLUMBING FIXTURES LOCATED IN ADJACENT RESTROOM
TO BE PROVIDED IN ACCESSIBLE CEILING.
221109 PROVIDE SHUTOFF VALVE, CHECK VALVE, BALANCING
VALVE, AND SHUTOFF VALVE IN DIRECTION OF WATER
FLOW. BALANCE TO 0.5 GPM.
221110 CONNECT DOMESTIC HOT WATER RETURN PIPE TO
DOMESTIC HOT WATER BRANCH PIPE SERVING THE
SHOWER. CONNECT IT AS CLOSE AS POSSIBLE TO THE
SHOWER CONNECTION TO MINIMIZE DEAD-LEG.
221111 CONNECT DOMESTIC HOT WATER RETURN PIPE TO
DOMESTIC HOT WATER BRANCH PIPE SERVING THE
LAVATORY. CONNECT IT AS CLOSE AS POSSIBLE TO THE
LAVATORY HOT WATER CONNECTION TO MINIMIZE
DEAD-LEG.
224701 INSTALL NEW ELECTRIC WATER COOLER IN PLACE OF
EXISTING. RECONNECT TO EXISTING DOMESTIC AND
SANITARY PIPING IN THE SPACE.
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR DOMESTIC PLUMBING INSTALLATION
PLAN
NORTH
SCALE: 3/8" = 1'-0"
OVERALL PLUMBING INSTALLATION ENLARGED
PLAN - TOILET 217
NOTES AND INFORMATION.
B. WHERE PIPE SIZES MAY NOT BE INDICATED SERVING A FIXTURE,
PROVIDE SIZES AS INDICATED IN THE PLUMBING FIXTURE
SCHEDULE.
C. INSTALL ALL EQUIPMENT, FIXTURES AND ASSOCIATED
ACCESSORIES AS PER MANUFACTURER'S RECOMMENDATIONS.
D. COORDINATE WITH ALL OTHER DISCIPLINES BEFORE INSTALLING
ANY PIPING DEVICES.
E. EXACT LOCATION OF PLUMBING FIXTURES SHALL BE
COORDINATED WITH ARCHITECTURAL PLANS TO MEET ADA
REQUIREMENTS.
F. SANITARY PIPING GREATER THAN 3" IN DIAMETER SHALL BE
SLOPPED AT 1/8" PER FOOT. SANITARY PIPING 3" OR LESS IN
DIAMETER SHALL BE SLOPPED AT 1/4" PER FOOT.
G. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
CONDITION OF EXISTING SANITARY PIPING (TO WHICH NEW
SANITARY PIPING IS CONNECTED). IF THE CONDITION IS NOT
ACCEPTABLE, CONTRACTOR SHALL BE RESPONSIBLE FOR
REPLACING OF PIPING.
H. PRIOR TO INSTALLATION AND POST INSTALLATION CONTRACTOR
SHALL BE RESPONSIBLE FOR CLEANING AND UNCLOGGING OF
EXISTING SANITARY LINES OF ANY BLOCKAGE OR DEBRIS.
P3.2
P3.2
EX-4" SAN
EX-4" SAN
2" SAN
EX-4" SAN
4" SAN
EX-4" S
AN
EX-4" S
AN
4" SAN
EX-4" S
AN
4" SAN
2" V
E X
-4
V -V
T R
E X
-4
V -V
T R
E X
-4
V -V
T R
E X
-2
V
E X
-4
V -V
T R
E X
-4
V -V
T R
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
ADDENDUM 1 04-24-2025
MARCH 10, 2025
SSB
JMC
P3.1
SANITARY AND VENT RISER DIAGRAM - 1
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
SCALE: N.T.S.
OVERALL SANITARY / VENT RISER DIAGRAM
NOTES AND INFORMATION.
B. WHERE PIPE SIZES MAY NOT BE INDICATED SERVING A FIXTURE,
PROVIDE SIZES AS INDICATED IN THE PLUMBING FIXTURE
SCHEDULE.
C. INSTALL ALL EQUIPMENT, FIXTURES AND ASSOCIATED
ACCESSORIES AS PER MANUFACTURER'S RECOMMENDATIONS.
D. COORDINATE WITH ALL OTHER DISCIPLINES BEFORE INSTALLING
ANY PIPING DEVICES.
E. EXACT LOCATION OF PLUMBING FIXTURES SHALL BE
COORDINATED WITH ARCHITECTURAL PLANS TO MEET ADA
REQUIREMENTS.
F. SANITARY PIPING GREATER THAN 3" IN DIAMETER SHALL BE
SLOPPED AT 1/8" PER FOOT. SANITARY PIPING 3" OR LESS IN
DIAMETER SHALL BE SLOPPED AT 1/4" PER FOOT.
G. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
CONDITION OF EXISTING SANITARY PIPING (TO WHICH NEW
SANITARY PIPING IS CONNECTED). IF THE CONDITION IS NOT
ACCEPTABLE, CONTRACTOR SHALL BE RESPONSIBLE FOR
REPLACING OF PIPING.
H. PRIOR TO INSTALLATION AND POST INSTALLATION CONTRACTOR
SHALL BE RESPONSIBLE FOR CLEANING AND UNCLOGGING OF
EXISTING SANITARY LINES OF ANY BLOCKAGE OR DEBRIS.
EWC-1
EWC-1
L-1
WC-1
WC-1
L-1
FD-1
FD-1
FD-1
X-B-1
X-L-1
X-WC-1
X-UR-1
EX-4" S
AN
EX-4" SAN
EX-2" V
EX-4" S
AN
EX-4" SAN
4" SAN
1 1/2" V
2" V
1 1/2" V
1 1/2" V
V
1 1/2" V E
X -4
S
A N
EX-4" S
AN
V -V
T R
V -V
T R
WCO-1
2" V
4" S
AN
2" V
3" SAN
2" SAN
4" SAN
3" SAN
2" V
221104
221104
221104
4" SAN
2" SAN
1 1/2" V
EX-3" SAN
REFER TO 2/P3.2 FOR
CONTINUATION
4" SAN
WCO-1
2" S
AN
3" SAN
V
/2
V
2" V
4" SAN
WCO-1
2" V
4" SAN
WC-1
4" SAN
2" V
X-S-1
X-S-2
2" SAN
EX-2" V
EX-2" V
EX-2" V
EX-2" V
V
2" SAN
2" SAN
REFER TO 1/P3.2 FOR
CONTINUATION
E X
-4
V -V
T R
221304
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
ADDENDUM 1 04-24-2025
MARCH 10, 2025
SSB
JMC
P3.2
SANITARY AND VENT RISER DIAGRAM - 2
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
SCALE: N.T.S.
SANITARY/VENT RISER DIAGRAM - SOUTH END
ENLARGED
SCALE: N.T.S.
SANITARY/VENT RISER DIAGRAM - NORTH END
ENLARGED
KEYNOTES
221104 CONNECT NEW PIPING TO EXISTING VENT THRU ROOF.
221304 CONNECT NEW SANITARY PIPING INTO EXISTING
RISER.
O
S
S O
S
S
S
S
S
S
S
OS
S
S
S
S
S
OS
S
OS
S
OS
S
OC
OC
OC
S
S
GENERAL NOTES:
A. DASHED LINES INDICATE EXISTING ELECTRICAL EQUIPMENT TO BE
REMOVED UON. REMOVE ASSOCIATED ELECTRICAL ITEMS (E.G.
CABLE, CONDUIT, SUPPORTS, DISCONNECTS, ETC.) COMPLETE
BACK TO POWER AND/OR SIGNAL SOURCE OR TO NEAREST
REMAINING WIRING DEVICE(S), JUNCTION BOX, PULL BOX UON.
B. SHADED LINES INDICATE EXISTING ELECTRICAL ITEMS TO REMAIN
UON.
C. EXISTING LIGHTING, POWER, SYSTEMS DEVICES / EQUIPMENT TO
REMAIN UNLESS OTHERWISE NOTED.
D. REMOVE EXISTING SYSTEMS, MATERIALS, AND EQUIPMENT WHICH
ARE MADE OBSOLETE OR WHICH INTERFERE WITH THE
CONSTRUCTION OF THE PROJECT.
a. REINSTALL AND RECONNECT ANY SUCH SYSTEMS, MATERIALS, AND EQUIPMENT WHICH ARE REQUIRED TO COMPLETE THE
PROJECT.
E. WHERE EXISTING EQUIPMENT OR MATERIALS ARE REMOVED OR
CHANGED, ALL BRANCH CONDUITS, WHICH NO LONGER ARE IN
SERVICE, SHALL BE REMOVED AS DIRECTED BY OWNER'S
CONSTRUCTION REPRESENTATIVE. IF, IN THE COURSE OF THE
WORK, OUTLETS ARE COVERED UP OR OTHERWISE RENDERED
INACCESSIBLE, ALL WIRING TO SAME SHALL BE REMOVED TO THE
SOURCE. IF A CIRCUIT THAT MUST REMAIN IN SERVICE IS
INTERRUPTED, IT SHALL BE RECONNECTED BY THE MOST
INCONSPICUOUS MEANS SO AS TO REMAIN OPERATIONAL, WITH
SAME CAPACITY AS BEFORE. ALL BUILDING SURFACES DAMAGED,
AND OPENING LEFT BY REMOVAL OF BOXES, CONDUIT,
EQUIPMENT, ETC. SHALL BE REPAIRED BY THE CONTRACTOR. ALL
OPENING LEFT IN WIRING DEVICE, JUNCTION BOX, PULL BOXES,
ETC. SHALL BE PLUGGED PER NEC.
F. WHERE NEW OPENINGS ARE CUT AND CONCEALED CONDUITS,
ETC. ARE ENCOUNTERED, ELECTRICAL ITEMS SHALL BE REMOVED
OR RELOCATED TO THE POINT WHERE FINISHED SURFACES CAN
BE PATCHED/REPAIRED SO THAT NO EVIDENCE OF THE FORMER
INSTALLATION REMAINS.
G. REFER TO OTHER TRADE DRAWINGS (I.E. ARCHITECTURAL,
MECHANICAL, PLUMBING, ETC.) FOR REMOVAL/INSTALLATION
WORK BY OTHER TRADES. E.C. SHALL FIELD COORDINATE WITH
OTHER TRADES TO ENSURE POWER IS DE-ENERGIZED AND
LOCKED OUT/TAGGED OUT TO ACCOMMODATE CONSTRUCTION OF
THESE OTHER TRADES; AND TO ENSURE THAT EXISTING AND/OR
NEW ELECTRICAL IS PROTECTED DURING CONSTRUCTION.
H. FIELD COORDINATE WITH OWNER, PRIOR TO CONSTRUCTION, TO
DETERMINE ELECTRICAL ITEMS (I.E. WIRING DEVICES, LIGHTING
FIXTURES, ETC.) TO BE SALVED DURING CONSTRUCTION.
CAREFULLY REMOVE AND PROTECT SALVAGED ELECTRICAL AS
NECESSARY. REMOVED/SALVAGED ELECTRICAL ITEMS SHALL BE
STORED BY THE CONTRACTOR IN A ROOM TO BE DESINGATED BY
THE OWNER.
RECEPTION
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
ENTRY HALL
CORRIDOR
CORRIDOR
PSYCHIATRIST
OFFICE
NURSE
EXAM
WAITING
MECH
LIBRARY/VISITOR
CORRIDOR
ALCOVE
HVAC
VESTIBULE
ELEVATOR
STAIR
CLOSET
JAN
MEN
WOMEN
LINEN/JAN
BATH
OFFICE
CLOSET
WAITING
CORRIDOR
CLOSET
MECH
FRONT
ENTRY
ENTRY HALL
BATH
VEST
022603
OFFICE
BATH
OFFICE
OFFICE
ENTRY HALL
OFFICE
MECH
LIBRARY/VISITOR
CORRIDOR
OFFICE
LINEN/JAN
BATH
MEN
WOMEN
CORRIDOR
EXAM
NURSE
022608
022608
022608 022608 022608 022608
022608
022608
022608
022608022608
022608
022608
022608
022608
022608 022608
022608
022607
022607022607
022607
022607022607
022607
022607
022607
022612
022612
022612
022612
022608
022610
022611
022611
022610
022611
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
022605022605022605022605022605
022605
022605
022605
022605
022605
022605
022605
022605
022605
022605
022605
022605
022605
022605
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
Addendum 1 04/23/2025
03/10/2025
TKF
AER
ED2.1
FIRST FLOOR POWER AND LIGHTING PLAN - REMOVALS
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
KEYNOTES
022603 EXISTING ELECTRIC DRINKING FOUNTAIN TO BE REMOVED
FOR REPLACEMENT. DISCONNECT AND REMOVE
ELECTRICAL ITEMS FROM UNIT, ELECTRICAL ITEMS TO
REMAIN FOR RECONNECTION TO NEW DRINKING FOUNTAIN.
CONTRACTOR TO FIELD VERIFY EXISTING RECEPTACLE
TYPE AND INSTALL GFCI (PER NEC) AS REQUIRED.
022605 EXISTING CEILING TO BE TEMPORARILY REMOVED TO
ALLOW FOR NEW HVAC PIPING. EXISTING CEILING
MOUNTED ELECTRICAL ITEMS (LIGHTING FIXTURE, LIGHTING
CONTROL DEVICES, FIRE ALARM SMOKE DETECTORS,
WIRELESS ACCESS POINTS, ETC) SHALL BE TEMPORARILY
SUPPORTED TO CONTINUE OPERATING WHILE CEILINGS
ARE DOWN.
022607 EXISTING LIGHTING CONTROL TOGGLE SWITCH TO BE
REMOVED FOR REPLACEMENT. EXISTING WIRING DEVICE
BOX AND CIRCUITRY TO REMAIN. REFER TO DRAWING E2.1
FOR RE-CONNECTION OF THE EXISTING CIRCUITRY TO NEW
LIGHTING CONTROL SWITCH.
022608 EXISTING LIGHTING FIXTURE(S) TO BE REMOVED FOR
REPLACEMENT. EXISTING CIRCUITRY TO REMAIN FOR
RE-CONNECTION TO NEW AREA LIGHTING. REFER TO
DRAWING E2.1 FOR RE-CONNECTION OF THE EXISTING
CIRCUITRY TO NEW LIGHTING FIXTURE(S).
022610 EXISTING EMERGENCY EXIT LIGHTING FIXTURE TO BE
REMOVED FOR REPLACEMENT. EXISTING CIRCUITRY TO
REMAIN FOR RE-CONNNECTION TO NEW EMERGENCY EXIT
LIGHTING FIXTURE(S).
022611 EXISTING CEILING OCCUPANCY SENSOR TO BE REMOVED
FOR REPLACEMENT. EXISTING CIRCUITRY TO REMAIN FOR
RE-CONNNECTION TO NEW OCCUPANCY SENSOR(S).
022612 EXISTING LIGHTING CONTROL TOGGLE SWITCH(ES) TO BE
REMOVED COMPLETE BACK TO SOURCE OR NEAREST
REMAINING WIRING DEVICE. DISCONNECT AND REMOVE ALL
ASSOCIATED ELECTRICAL ITEMS (I.E. CABLE, CONDUIT,
SUPPORTS, WIRING DEVICE BOX, ETC.) COMPLETE.
EXISTING CIRCUITRY TO REMAIN FOR RE-CONNECTION TO
NEW AREA LIGHTING. REFER TO DRAWING E2.2 FOR
RE-CONNECTION OF THE EXISTING CIRCUITRY TO NEW
LIGHTING FIXTURE(S).
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR POWER PLAN - REMOVALS
0226XX
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR LIGHTING PLAN - REMOVALS
O
S
S O
S
S
OS
S D
S
S D
S D
S D
S D
S
OS
S
OS
S D
OC
OC
OC
OC
S D
S D
OC OC
OC
OC OC
OC
OC
OC
OC
OC
GENERAL NOTES
A. ALL NEW DEVICES SHOWN ON EXISTING WALLS TO BE FLUSH
MOUNTED. CUT AND PATCH EXISTING WALL(S) AS NEEDED.
B. CONTRACTOR SHALL FIELD COORDINATE, PRIOR TO
CONSTRUCTION, EXACT MOUNTING HEIGHT AND LOCATIONS FOR
WIRING DEVICES.
C. NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE WITH EXISTING
NOTIFIER BY HONEYWELL #NFS-320 SERIES SYSTEM. FIELD
VERIFY/LOCATE THE EXISTING FIRE ALARM CONTROL PANEL.
MODIFY AND EXTEND EXISTING SYSTEM CABLE/CONDUIT AS
NECESSARY FOR NEW DEVICES.
D. NEW LIGHTING FIXTURES SHALL BE CONNECTED TO EXISTING
LIGHT FIXTURE BRANCH CIRCUITRY UON.
E. HEAVY LINES INDICATE NEW ELECTRICAL TO BE INSTALLED UON.
F. SHADED LINES INDICATE EXISTING ELECTRICAL TO REMAIN UON.
RECEPTION
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
ENTRY HALL
CORRIDOR
CORRIDOR
PSYCHIATRIST
OFFICE
NURSE
EXAM
WAITING
MECH
LIBRARY/VISITOR
CORRIDOR
ALCOVE
HVAC
VESTIBULE
ELEVATOR
STAIR
CLOSET
JAN
MEN
WOMEN
LINEN/JAN
BATH
OFFICE
CLOSET
WAITING
CORRIDOR
CLOSET
MECH
FRONT
ENTRY
ENTRY HALL
BATH
VEST
260501
A2 A2
A2 A2 A1
A2
A2 A2
A2
A2
A2E
NL
A2
A2 A2
A1 A2 A2
A2A2A2
A2E
NL
A2A2A2E
NL
A2
A2
A2 A1
A1
A1
A1 A2E
NL
A2
A3
A3 A3
B1
OFFICE
LINEN/JAN
BATH
MEN
WOMEN
CORRIDOR
EXAM
NURSE
LIBRARY/VISITOR
MECH
133OFFICE
ENTRY HALL
OFFICE
OFFICE
BATH
OFFICE
CORRIDOR
X1
X1
260505 260505
260505 260505
260505
260505260505
260505
B1
260507
260508
260507
260507
260507
260507
260508
260508 260508
260508 260507
260507
260507
260508 260508
260508
260507
260507260507 260508
260508
260507 260508
260507
260507
260507
260507
260507
260508
260508
260508
260508
260508
260507
260508
260507
260508
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
Addendum 1 04/23/2025
03/10/2025
TKF
AER
E2.1
FIRST FLOOR POWER AND LIGHTING PLANS - INSTALLATION
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
KEYNOTES
260501 NEW DRINKING FOUNTAIN. MODIFY AND EXTEND
REMOVED ELECTRICAL ITEMS AS NEEDED TO NEW UNIT.
REFERENCE REMOVAL KEYNOTE 022603 ON DRAWING
ED2.1. CONTRACTOR TO FIELD VERIFY EXISTING
RECEPTACLE POWERING FOUNTAIN AND PROVIDE GFCI
TYPE RECEPTACLE AS REQUIRED BY NEC.
260505 FURNISH AND INSTALL NEW LIGHTING CONTROL DIMMER
SWITCH IN EXISTING WIRING DEVICE BOX; REFER TO
KEYNOTE 022607 OR 022609 ON ED2.X SERIES
DRAWINGS. CONNECT TO SAME CIRCUIT AS EXISTING
REMOVED LIGHTING CONTROL SWITCH, MODIFY AND
EXTEND EXISTING CABLE/CONDUIT TO NEW LIGHTING
FIXTURE(S) AS REQUIRED. DIMMER SWITCH SHALL BE
COMPATIBLE WITH DIMMABLE LED DRIVERS IN LIGHTING
FIXTURE(S).
260507 PROVIDE NEW LIGHTING IN ROOM/AREA AS INDICATED.
260508 RE-INSTALL EXISTING CEILING LIGHTING FIXTURES IN
THEIR APPROXIMATE ORIGINAL LOCATION. EXISTING
LIGHTING FIXTURE CONTROL TO REMAIN.
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR POWER PLAN - INSTALLATION
NORTH
SCALE: 1/8" = 1'-0"
FIRST FLOOR LIGHTING PLAN - INSTALLATION
2605XX
F s
F s
F s
S S
S
S
S
S O
S
S O
S
S D
S D
S D
S D
S D
S D
S D
OC OC
OCOCOCOCOC
OC
GENERAL NOTES
A. ALL NEW DEVICES SHOWN ON EXISTING WALLS TO BE FLUSH
MOUNTED. CUT AND PATCH EXISTING WALL(S) AS NEEDED.
B. CONTRACTOR SHALL FIELD COORDINATE, PRIOR TO
CONSTRUCTION, EXACT MOUNTING HEIGHT AND LOCATIONS FOR
WIRING DEVICES.
C. NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE WITH EXISTING
NOTIFIER BY HONEYWELL #NFS-320 SERIES SYSTEM. FIELD
VERIFY/LOCATE THE EXISTING FIRE ALARM CONTROL PANEL.
MODIFY AND EXTEND EXISTING SYSTEM CABLE/CONDUIT AS
NECESSARY FOR NEW DEVICES.
D. NEW LIGHTING FIXTURES SHALL BE CONNECTED TO EXISTING
LIGHT FIXTURE BRANCH CIRCUITRY UON.
E. HEAVY LINES INDICATE NEW ELECTRICAL TO BE INSTALLED UON.
F. SHADED LINES INDICATE EXISTING ELECTRICAL TO REMAIN UON.
+48"
+48" +48"
OFFICE
CLASSROOM
OFFICE
OFFICE
CLASSROOM
CORRIDOR
CLASSROOM
220MECH
STORAGE
CLASROOM
MECH
STORAGE
CLASSROOM
MECH
MECH
STAIR
ELEVATOR
CLASSROOM
WORK
ROOM
MECH
VESTIBULE
STAFF
TOILET
TOILET
TOILET
260502 260502
260502
260504
260506
260506 260506 260506
OFFICE
CLASSROOM
OFFICE
OFFICE
CLASSROOM
CORRIDOR
CLASSROOM
MECH
STORAGE
CLASROOM
MECH
STORAGE
CLASSROOM
MECH
MECH
STAIR
ELEVATOR
CLASSROOM
WORK
ROOM
MECH
VESTIBULE
STAFF
TOILET
TOILET
TOILET
211 260503
260503260503
260503260503
A1F a
A1F
A1F OS
OS
a
OS
B1 b b
A2
A2
A2
A2
A2A2
A2
A2 A2
A2
A2
A2 A2
A2 A2
A2
A2
A2 A2
A2 A2
A2
A2
A2 A2
A2
260503
260503
260503 A1A1
260503
260503 260503
260503
260503
260505 260505 260505 260505 260505
260505260505
260507
260507260507260507
260507
260508
260508 260508 260508
260508
DATE
DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DECA REVIEWED
FOR INTENT ONLY
DECA LOG #
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DIVISION OF
ENGINEERING
AGENCY
AUTHORIZED AGENT
DATE
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING NO.
AS BUILT DATE
RTA DATE
DRAWING INFORMATION
REVISIONS DATE
1950 HAGGARD COURT
LEXINGTON, KENTUCKY
40505 (858) 299-5226
PROJECT NUMBER:
Addendum 1 04/23/2025
03/10/2025
TKF
AER
E2.2
SECOND FLOOR POWER, SYSTEMS AND LIGHTING PLANS - INSTALLATION
BRADLEY HALL PLUMBING UPGRADE
2431-4101-70
KEYNOTES
260502 CONNECT TO SAME CIRCUIT AS REMOVED DUPLEX
RECEPTACLE, REFERENCE KEYNOTE 022601 ON DRAWING
ED2.2. MODIFY AND EXTEND CIRCUITRY CABLE/CONDUIT AS
REQUIRED.
260503 CONNECT NEW LIGHTING FIXTURE(S) TO SAME CIRCUIT AS
EXISTING REMOVED ROOM/AREA LIGHTING FIXTURES; SEE
DRAWING ED2.1 FOR ROOM/AREA LIGHTING FIXTURES TO BE
REMOVED. MODIFY AND EXTEND EXISTING CIRCUITRY
CABLING/CONDUIT TO NEW LIGHTING FIXTURES/LIGHTING
CONTROL DEVICES AS INDICATED.
260504 NEW DRINKING FOUNTAIN. MODIFY AND EXTEND REMOVED
ELECTRICAL ITEMS AS NEEDED TO NEW UNIT. REFERENCE
REMOVAL KEYNOTE 022603 ON DRAWING ED2.2.
CONTRACTOR TO FIELD VERIFY EXISTING RECEPTACLE
TYPE AND PROVIDE GFCI TYPE RECEPTACLE AS REQUIRED
BY NEC.
260505 FURNISH AND INSTALL NEW LIGHTING CONTROL DIMMER
SWITCH IN EXISTING WIRING DEVICE BOX; REFER TO
KEYNOTE 022607 OR 022609 ON ED2.X SERIES DRAWINGS.
CONNECT TO SAME CIRCUIT AS EXISTING REMOVED
LIGHTING CONTROL SWITCH, MODIFY AND EXTEND EXISTING
CABLE/CONDUIT TO NEW LIGHTING FIXTURE(S) AS
REQUIRED. DIMMER SWITCH SHALL BE COMPATIBLE WITH
DIMMABLE LED DRIVERS IN LIGHTING FIXTURE(S).
260506 CONNECT TO SPARE, SPACE OR ABANDONED 20A/1P
CIRCUIT FROM NEAREST 120V PANEL. FURNISH AND INSTALL
20A/1P BREAKER AS NEEDED. NEW BREAKER SHALL MATCH
EXISTING PANEL MANUFACTURER AND AIC RATING. UPDATE
PANEL DIRECTORY. PROVIDE A MAXIMUM OF SIX (6)
RECEPTACLES PER CIRCUIT.
260507 PROVIDE NEW LIGHTING IN ROOM/AREA AS INDICATED.
260508 RE-INSTALL EXISTING CEILING LIGHTING FIXTURES IN THEIR
APPROXIMATE ORIGINAL LOCATION. EXISTING LIGHTING
FIXTURE CONTROL TO REMAIN.
NORTH
SCALE: 1/8" = 1'-0"
SECOND FLOOR POWER AND SYSTEMS PLAN -
INSTALLATION
NORTH
SCALE: 1/8" = 1'-0"
SECOND FLOOR LIGHTING PLAN - INSTALLATION
2605XX
LIGHTING FIXTURE SCHEDULE
TYPE LAMP WATTAGE VOLTS DESCRIPTION BASIS OF DESIGN
EQUAL MANUFACTURER APPROVED
BY ENGINEER
EQUAL MANUFACTURER APPROVED
BY ENGINEER TYPE COMMENTS
A1 LED 30 W 120V 2'x2' GENERAL LED RECESSED FLAT PANEL, 3669 LUMENS, 30.1W, 3500K CCT, 80 CRI, SATIN WHITE DIFFUSER
AND MULTI-VOLT DRIVER DIMMABLE TO 10%.
ACUITY BRANDS LITHONIA CPX-2X2-3200LM-80CRI-35K-SWL-MIN10-MVOLT HUBBELL LIGHTING COLUMBIA CBT22 SERIES AS
AN APPROVED EQUAL
COOPER METALUX LIGHTING 22FP SERIES AS AN
APPROVED EQUAL
A1F LED 30 W 120V 2'x2' GENERAL LED RECESSED FLAT PANEL, 3669 LUMENS, 30.1W, 3500K CCT, 80 CRI, SATIN WHITE DIFFUSER, DRYWALL GRID ADAPTER AND MULTI-VOLT DRIVER DIMMABLE TO 10%.
ACUITY BRANDS LITHONIA CPX-2X2-3200LM-80CRI-35K-SWL-MIN10-MVOLT-DGA22 HUBBELL LIGHTING COLUMBIA CBT22 SERIES AS
AN APPROVED EQUAL
COOPER METALUX LIGHTING 22FP SERIES AS AN
APPROVED EQUAL
A2 LED 25 W 120V 2'x4' GENERAL LED RECESSED FLAT PANEL, 3287 LUMENS, 24.6W, 3500K CCT, 80 CRI AND MULTI-VOLT DRIVER
DIMMABLE TO 10%.
ACUITY BRANDS LITHONIA CPX-2X4-3000LM-80CRI-35K-SWL-MIN10-MVOLT HUBBELL LIGHTING COLUMBIA CBT24 SERIES AS
AN APPROVED EQUAL
COOPER METALUX LIGHTING 24FP SERIES AS AN
APPROVED EQUAL
A2E LED 25 W 120V 2'x4' GENERAL LED RECESSED FLAT PANEL, 3287 LUMENS, 24.6W, 3500K CCT, 80 CRI, MULTI-VOLT DRIVER
DIMMABLE TO 10% AND 10W EMERGENCY BATTERY.
ACUITY BRANDS LITHONIA CPX-2X4-3000LM-80CRI-35K-SWL-MIN10-MVOLT-E10WLCP HUBBELL LIGHTING COLUMBIA CBT24 SERIES AS
AN APPROVED EQUAL
COOPER METALUX LIGHTING 24FP SERIES AS AN
APPROVED EQUAL
A3 LED 42 W 120V 2'x4' GENERAL LED RECESSED FLAT PANEL, 3287 LUMENS, 41.8W, 3500K CCT, 80 CRI AND MULTI-VOLT DRIVER
DIMMABLE TO 10%.
ACUITY BRANDS LITHONIA CPX-2X4-3000LM-80CRI-35K-SWL-MIN10-MVOLT HUBBELL LIGHTING COLUMBIA CBT24 SERIES AS
AN APPROVED EQUAL
COOPER METALUX LIGHTING 24FP SERIES AS AN
APPROVED EQUAL
B1 LED 9 W 120V 6" OPEN RECESSED LED DOWNLIGHT, 758.1 LUMENS, 8.9W, 3500K CCT, CLEAR SEMI-SPECULAR TRIM, WHITE
PAINTED FLANGE WITH MULTI-VOLT DRIVER DIMMABLE DOWN TO 10%.
ACUITY BRANDS LITHONIA LDN6-35/07-L06-AR-LSS-TRW-MVOLT-GZ10- PRESCOLITE LFR SERIES AS AN APPROVED
EQUAL
COOPER HALO SERIES AS AN APPROVED EQUAL
X1 LED 1 W 120V POLYCARBONATE LED EXIT SIGN, RED LETTERS, BATTERY BACKUP SUITABLE FOR 90 MINUTES OF OPERATION WITH SELF-DIAGNOSTICS, WHITE HOUSING, SINGLE AND/OR DOUBLE FACE MOUNTED TO CEILING OR END.
ACUITY BRANDS LITHONIA LQM-S-W-3-120/277-EL-N COMPASS CER SERIES AS AN APPROVED EQUAL COOPER SURE-LITES LPX SERIES AS AN
APPROVED EQUAL
CEILING MOUNT. PROVIDE ARROWS AS
SHOWN ON PLANS.