Addendum Three.pdf

PDF 861 KB Posted

Attached to
RFB-103-27 Park Green River Emergency Campground Flood
Solicitation number
RFB 785 2700000170 4
Issued by
Nelson County, Kentucky

About this file

This is Addendum Three to an Invitation to Bid (RFB-103-27) issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration, for emergency flood repair work at Green River Campground in Campbellsville, Kentucky. The addendum, dated October 30, 2026, establishes binding changes to the original specifications and drawings dated September 15, 2026. Final technical questions must be submitted by 12:00 PM EST on November 4, 2026, with a final addendum to be issued on that same date if needed. The project is identified as Engineering File No. 670-CC2Q-GR10-00 and C/S Project No. 2512.

The addendum includes general provisions allowing contractors to stay on-site in RVs or camping vehicles at a cost of $30.00 per night per campsite, with contractors responsible for their own trash, sanitary waste removal, electrical, and water supply. One bathhouse will remain open for shower use, which contractors must clean and maintain. Regarding specifications and drawings, the addendum permits an alternative to the originally specified 3-inch I.P.S. DR11 HDPE water mains, allowing instead 2-inch SDR 21 PVC piping that meets ASTM D2241 and NSF/ANSI 61 standards for potable water, with detailed requirements for joints, fittings, valves, and installation procedures. Additional revisions include modifications to detail 2 on sheet C503 related to water system thrust blocking details.

View the file

Other files

File Type Posted
Final_RFB_785_2700000170_4_SO_FORM.PDF PDF
Final_RFB_785_2700000170_1_SO_FORM.PDF PDF
Final_RFB_785_2700000170_3_SO_FORM.PDF PDF
Addendum Two.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-103-27

FOR: Emergency Flood Repair Green River Campground Department of Parks Campbellsville, Kentucky

DATE: October 30, 2026

RFB-785-2700000170

ADDENDUM NO. Three (3)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Refer to attached addendum for all additions, deletions, and/or changes to specifications and/or drawings.

END OF ADDENDUM

Invitation to Bid No. RFB-103-27 For: Emergency Flood Repair Green River Campground Department of Parks Campbellsville, Kentucky

Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration

Green River Campground Emergency Flood Repair Engineering File No. 670-CC2Q-GR10-00 C/S Project No. 2512

RFB 103-27

2026.10.30

Addendum No. 03 _ The original specifications and drawings dated RTA 09/15/2026 for the above referenced project are amended as noted in this Addendum.

Receipt of this Addendum shall be acknowledged by inserting its number in the space provided on the Official Bid Document for RFB 103-27.

GENERAL

1) Due to the bid date moving in Addendum 02: Final questions are due by 12:00 PM EST, November 04, 2026. After this time, no other questions will be answered that are technical. If needed, the final addendum will be issued November 04, 2026.

2) Contractors may stay on site in RVs or other camping vehicles. Contractors will be responsible for their own trash and sanitary waste removal as the campsites do not have sanitary connections. Contractors will also be responsible for their own electrical and water during the work. One bathhouse will be kept open for use. Use of the bathhouse for showering only is acceptable, however, the General Contractor will be responsible for cleaning and maintaining the facility. The cost is $30.00 per night per campsite.

SPECIFICATIONS

3) None

DRAWINGS

1) Sheet C500, C501, C502, C503 – As an alternative to 3” I.P.S. DR11 HDPE, water mains may be 2” SDR 21 PVC, ASTM D2241, NSF/ANSI 61 listed for potable water. Joints shall be integral bell with elastomeric gasket per ASTM D3139, gaskets per ASTM F477. Fittings shall be ASTM D2467 (Schedule 80 socket), with solvent cement per ASTM D2564, NSF/ANSI 61 listed for potable water. Primer shall be ASTM F656, NSF/ANSI 61 listed. Joining procedure shall be ASTM D2855 (two-step method with primer and cement). Valves must be 2" mechanical joint gate valves certified to “meet applicable requirements of C509/C515. Valves must be connected to pipe with mechanical joint transition gasket (IPS × DI) and restraining mechanical joint gland for IPS-OD PVC. Transitions to HDPE service lines must be by threaded service saddle adapter to compression couplings with stainless steel inserts inside HDPE for stiffener.

2) Sheet C503 – Drawing Revision to detail 2/C503. See detail for full assembly modification.

END of ADDENDUM

WWW.CLOTFELTER-SAMOKAR.COM

C

LO

TF

EL

TE

R -S

AM

O

KA

R

REVISION HISTORY OF THIS DRAWING

GREEN RIVER CAMPGROUND EMERGENCY

FLOOD REPAIR

DRAWING NO.

KDM

09/15/2026

228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605

AS-BUILT DATE

DECA LOG #

DESCRIPTION OF REVISIONS DATE

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

A & E FILE NO.

DRAWING DATE

DRAWN BY

CHECKED BY

PHASE

RTA DATE

RTA

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

ACCOUNT NO.

670-CC2Q-GR10-00

S T A

T E O F KENT UCK

Y

P R

O

F E S S IO NA L ENG IN

EE

R20203

L I C E N S E D

JOSEPH E.

MATESEVAC

09/15/2026

Paducah, KY Office 2301 McCracken Blvd, Paducah, KY 42001

270-443-1995 / BFWengineers.com

Copyright © 2024 / Bacon Farmer Workman Engineering & Testing, Inc.

JEM

09/15/2026

WATER SYSTEM DETAILS

C503

THRUST / LBS. OF PRESSURETYPICAL THRUST BLOCKING DETAILS

PLAN OF 90° BEND

PLAN OF TEE

INSPECTOR PRIOR TO BACKFILLING.

THE CURRENT ADDITION OF THE AWWA C-105.

PORTLAND CEMENT CONCRETE, 2500 PSI, MINIMUM.

THRUST BLOCKS SHALL BE CONSTRUCTED WITH CLASS "B"

BLOCKING SHALL BE POURED AFTER THE POLYETHYLENE WRAP IS

WRAPPED WITH A POLYETHYLENE MATERIAL, 8-MIL. INSTALLED TO

USE ADDITIONAL CONCRETE AS REQUIRED FOR OVER EXCAVATION.

THRUST BLOCKS TO BE PLACED AGAINST UNDISTURBED EARTH.

BLOCKING SHALL BE INSPECTED BY THE DESIGN ENGINEER'S

ALL DUCTILE IRON PIPE, FITTINGS AND VALVES SHALL BE

PLAN OF CROSS

OR 22 1/2° BEND

PLAN OF 45°

IN PLACE.

NOTES:

ELEVATION

DEAD END ORPIPE SIZE 1/4" BEND

4"

16"

12"

10"

8"

6"

TEE

1/16" BEND 1/8" BEND

TYPICAL THRUST BLOCKING DETAILS (WATER)

UNDISTURBED EARTH

POLYETHYLENE

WRAP (TYP.)

WATER

MAIN (TYP.)

CONC. THRUST

BLOCKING (TYP.)

UNDISTURBED EARTH

WATER

MAIN (TYP.)

CONC. THRUST

BLOCKING (TYP.)

POLYETHYLENE

WRAP (TYP.)

UNDISTURBED EARTH

CONC. THRUST

BLOCKING (TYP.)

POLYETHYLENE

WRAP (TYP.)

ADHESIVE TAPE

(DUCT TAPE) TYP.

CONC. THRUST

BLOCKING (TYP.)

UNDISTURBED EARTH

POLYETHYLENE

WRAP (TYP.)

WATER

MAIN (TYP.)

WATER

MAIN (TYP.)

POLYETHYLENE

WRAP (TYP.)

CONC. THRUST

BLOCKING (TYP.)

SCALE: N.T.S.4

5' -0

" M

AX

MIN.

' M

IN

' M

AX

2'-0"

VA

R

IE

S

D

IA

6"

PI

PE

WHEN FINAL SURFACE

INCLUDES TOPSOIL AND GRASS

IN LANDSCAPED AREAS, USE

COMPACTED EARTH BACKFILL

TO 92% STANDARD PROCTOR.

SEE NOTE 3 FOR TRENCH

SECTION THROUGH ROCK.

UTILITY PIPE

COMPACTED DGA TO

95% STANDARD

PROCTOR

#9M

LIMESTONE

WHEN FINAL SURFACE IS

PAVEMENT USE CONTROLLED

LOW-STRENGTH MATERIAL

(FLOWABLE FILL)

IMPROVED SURFACE

IMPROVED SURFACES: MATCH

EXISTING. FOR ASPHALT, MATCH

EXISTING OR PATCH WITH MIN 6"

PC CONCRETE

FINAL SURFACE IN GRASS

AREAS, MIN. 6" TOPSOIL,

SEED, FERTILIZE, MULCH

AND PROTECT

UNIMPROVED SURFACE

INSTALL CONTINUOUS

TRACER WIRE

UNDISTURBED SOIL

UNDISTURBED SOILUTILITY PIPE

FINISHED GRADE

UTILITY LOCATION

TAPE

EXCAVATED

MATERIAL

SLOPE TO CONFORM TO

O.S.H.A. REQUIREMENTS.

UNDISTURBED SOIL

UNDISTURBED SOIL

UTILITY PIPE

UTILITY TRENCH DETAILS FOR FORCED SYSTEM

UNDISTURBED SOIL

SCALE: N.T.S.5

EXISTING GRADE

SEWER MAIN

WATER MAIN

1/2 PIPE LENGTH1/2 PIPE LENGTH

18" MINIMUM

WATER MAIN CROSSING SEWER

SCALE: N.T.S.3

NOTE:

1. CONCRETE PADS SHALL BE CONSTRUCTED AROUND ALL MAIN LINE.

2. CONCRETE PADS SHALL BE CLASS "A" TYPE PORTLAND CEMENT

CONCRETE WITH A WOOD FLOAT FINISH TOOLED EDGE.

3. THE VALVE BOX SHALL NOT TRANSMIT SHOCK OR STRESS TO THE VALVE.

CONCRETE VALVE

BLOCKING

8-MIL POLYETHYLENE

WRAP

RESILIENT SEAT

GATE VALVE (SEE

SPECS.)

2 PIECE CAST IRON VALVE

BOX (SEE SPECS.)

CAST IRON

COVER MARKED

"WATER" ON LID

18" SQUARE CONC. PAD

(FOR UNPAVED AREAS)

" M

IN

. C

O

VE

R

6" M

IN

VALVE DIA. + 12" MIN.

TYPICAL GATE VALVE AND BOX COLLAR

4"

WATER MAIN

#12 GAUGE COPPER WIRE

8" COPPER GROUND ROD

WIRE

CONNECTOR

SCALE: N.T.S.1

WATER MAINS SHALL BE BURIED A MINIMUM OF 36" BELOW GRADE

MEASURED FROM FINISHED GRADE TO THE TOP OUTSIDE OF PIPE.

PROPOSED

GRADE

CAST IRON MANHOLE

FRAME & LID

8"

#57 CRUSHED

STONE BASE

" M

IN

1'-0"

1'-0"

BRICK OR BLOCK

4'-0" DIA.

EARTH FILL

EARTH FILL

4" HOSE BIBB W/ VACUUM

BREAKER TAPPED TO BOTTOM

PART OF WATER MAIN

6'' PERFORATED PVC PIPE W/ END CAP.

BACKFILLED W/ #57 TO SUBGRADE AND WRAP

WITH NON/WOVEN FILTER FABRIC. INSTALL AT

1% SLOPE AND EXTEND LENGTH TO

DAYLIGHT TO DRAIN.

6 SCALE: N.T.S.

DRAIN VAULT FOR WATER MAIN

PRECAST CONCRETE MANHOLE

WITH "DOG-HOUSE" OPENINGS

FOR WATER MAIN. MANHOLE

SHALL REST UPON BRICK OR

BLOCK BASE AND SHALL NOT

CONTACT WATER MAIN

PRECAST

CONCRETE

LID

NO LEAD BRASS VACUUM

BREAKER

" M

IN

. 3

6" M

AX

#57 LIMESTONE

1" WATER LINE

2 SCALE: 1"=1'

LEAD-FREE, FREEZE PROOF "POTABLE" HYDRANT

ZURN WILKINS 700 XL DUAL CHECK

VALVE BACKFLOW PREVENTER OR

EQUIVALENT WITH THREADED

ADAPTERS AS REQUIRED

1" FORD CURB STOP VALVE OR

EQUIVALENT WITH THREADED

ADAPTERS AS REQUIRED

FORD TYPE A MODULAR METER PIT COVE

(FRAME AND LID COMBINED) 18" LID ON

18" METER PIT TILE OR EQUIVALVENT

MIN 6" x 6" x 4' Ø PRE-CAST

CONCRETE RING

DRAIN HOLE

FROST LINE

M

IN

1" STANDPIPE

HYDRANT CONNECTION PIECE

NO-LEAD 3/4” Any Flow® FROST-PROOF

YARD HYDRANT PART# AFNL7503

MIN. 3-FEET BURY DEPTH, 1" STANDPIPE

AND 3/4" HOSE THREADED OUTLET

REVISED DETAIL 2 10/29/26

Addendum Three
Item 1: Refer to attached addendum for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM