Addendum One .pdf
PDF 413 KB Posted
- Solicitation number
- RFB 785 2400000544 2
- Issued by
- Laurel County, Kentucky
About this file
This Addendum One document issued by the Commonwealth of Kentucky Department for Facilities and Support Services Division of Engineering and Contract Administration pertains to Invitation to Bid No. RFB-221-24 for the renovation of the Cosmetology program space at West Kentucky Community & Technical College (KCTCS) in Paducah, Kentucky. The addendum, dated April 2, 2024, clarifies specifications and drawing requirements for the general contractor performing the renovation work. Key clarifications include that paint specifications are not included in the project manual and painting of new walls is not required of the general contractor; Bradley model 780 24"x36" mirrors are the basis of design; Rakks bracket model EHR-1818 Clear Anodized must be used for metal support brackets with specific mounting heights referenced in revised details; and countertop heights on the south wall must be lowered to accommodate ADA compliance. The addendum also corrects a reference note numbering discrepancy on the floor plan from reference 20 to reference 17.
The addendum comprises four items and two attachments (A1.1 and A1.2) containing detailed architectural floor plans, door schedules, and construction details. The document specifies general construction requirements including patching and matching existing finishes, providing blocking for equipment installation, access panels for mechanical systems, fire-rated assembly maintenance, floor drain specifications, gypsum board installation standards, and caulking requirements for dissimilar materials. Hardware specifications for exterior storefront doors and interior doors are provided in detailed schedules with manufacturer information. The renovation addresses multiple cosmetology spaces including styling stations, shampoo sinks, manicure and pedicure areas, facial bed spaces, and support areas such as lockers, storage, and classrooms across first and second floor layouts.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_RFB_785_2400000544_1_SO_FORM.PDF | ||
| Final_RFB_785_2400000544_2_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-221-24
FOR: Renovate Cosmetology West KY CTC Kentucky Community & Technical College System Paducah, Kentucky
DATE: April 3, 2024
RFB-785-2400000544
ADDENDUM NO. One (1)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-221-24 For: Renovate Cosmetology West KY CTC Kentucky Community & Technical College System
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
P a g e | 1 of 2
T000-LASTNAME-
INT
INDIANA | ILLINOIS | KENTUCKY | OHIO
haferdesign.com
ADDENDUM
Project: KCTCS – Renovate Cosmetology Addendum No.: 001
Date: April 2, 2024
Owner: KCTCS – West Kentucky Project Number: CB60
Contract for: GC
The original specifications and drawings dated 03/05/2024 for the project noted above are amended as noted in this Addendum Number 001. Receipt of this addendum and any subsequent addenda must be acknowledged on the final bid documents. This addendum consists of four (4) item(s) and two (2) attachment(s).
Attachments: A1.1, A1.2
By: Luke Johnson
CC: eComm
QUESTIONS AND ANSWERS
1-1 Q. I know we’re adding some walls in this project but I see no spec of type of paint - Can I get a spec on that please?
A. Paint specification will not be included in the project manual. General contractor is not required to paint any new walls, bulkheads, ceilings, frames, or any other item as part of their scope of work.
1-2
Q. Can you provide a spec for the 24”x36” mirrors?
A. Bradley model 780 24”x36” is the basis of design.
1-3 Q. The Rakk Metal Support Brackets – Is there a model number? Do they need to be ADA compliant?
A. Mounting heights shown on detail 4 and 5 on sheet A1.2. Provide Rakks bracket EHR-1818 Clear
Anodized, see revised detail 4/A1.2. Additionally, lower counter top height on south wall as indicated on
A1.1 and shown in new detail 5/A1.2 for ADA countertop.
1-4 Q. page A1.1 - 2nd Floor plans there seems to be a reference note box labeled 20. However in the
References, the numbers only go as far as 18. I want to make sure nothing was left off or I’m not missing something.
A. Reference note has been updated to “17”.
P a g e | 2 of 2
DN
GENERAL FLOOR PLAN NOTES:
A. TOP OF FIRST FLOOR CONCRETE SLAB ELEVATION ESTABLISHED AT
100'-0".
B. ALL DIMENSIONS ON FLOOR PLANS ARE FROM FACE OF FINISH
GYPSUM BOARD, FACE OF MASONRY, FACE OF CONCRETE OR
CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE.
C. CONTRACTOR SHALL PATCH AND MATCH EXISTING WALL FINISHES
WITH LIKE MATERIALS AND FINISHES WHERE DISTURBED BY
CONSTRUCTION.
D. CONTRACTOR SHALL PROVIDE BLOCKING IN WALLS, CEILINGS, AND
ANY OTHER LOCATION AS REQUIRED FOR INSTALLATION OF
CASEWORK, SURFACE MOUNTED ITEMS, PROJECTION SCREENS,
MARKER BOARDS, TOILET ACCESSORIES, SINK ACCESSORIES, WALL
MOUNTED DOOR STOPS, AND ANY OTHER SURFACE MOUNTED ITEMS.
E. FOR INTERIOR FINISHES REFER TO THE MATERIAL FINISH LEGEND ON
SHEET A1.1.
F. CONTRACTOR SHALL PROVIDE ACCESS PANELS IN WALLS WHERE
SERVICE TO MECHANICAL, PLUMBING, ELECTRICAL, ETC. ELEMENTS
ARE TO BE ADJUSTED I.E. CLEANOUTS, VALVES DAMPERS, ETC.
ACCESS PANELS SHALL BE OF THE SAME RATING AS THE ADJACENT
WALL CONSTRUCTION.
G. CONTRACTOR SHALL PATCH FLOORING AND WHERE WALLS BASE
HAVE BEEN REMOVED DURING DEMOLITION WITH FLOORING AND
BASE THAT MATCHES EXISTING, ADJACENT FLOOR FINISHES UNLESS
NOTED OTHERWISE.
H. REFER TO ELEVATIONS AND DETAILS FOR CLARIFICATION OF WALL
FINISH EXTENTS.
I. CONTRACTOR SHALL CAULK DOOR FRAME FROM FLOOR
CONTINUOUSLY AT THE PERIMETER OF DOOR AND WINDOW FRAMES.
CAULK AFTER WALL COVERING IS INSTALLED (IF SPECIFIED).
J. MAINTAIN FIRE RATED ASSEMBLY IN WALLS, CEILINGS. FLOORS, ETC.
PROVIDE THROUGH-PENETRATION FIRESTOP SYSTEMS AT ALL
PENETRATIONS IN FIRE-RATED ASSEMBLIES. PROVIDE FIRE-RESISTIVE
JOINT SYSTEMS AT ALL JOINTS BETWEEN FIRE-RATED ASSEMBLIES
AND ADJACENT CONSTRUCTION.
K. FLOOR DRAINS SHALL BE RECESSED 1/2" TO 3/4" (BASED ON ROOM
SIZE) UNLESS NOTED OTHERWISE. SLOPE FLOOR TO PROVIDE
POSITIVE DRAINAGE.
L. HOLD GYPSUM BOARD 1/4" FROM FLOOR, CEILING AND ANY ADJACENT
SURFACE AND PROVIDE A CONTINUOUS BEAD OF ACOUSTICAL
SEALANT AROUND PERIMETER OF ACOUSTICAL PARTITIONS ON EACH
SIDE OF THE WALL. PROVIDE ACOUSTICAL FIRE SEALANT AT FIRE-
RATED PARTITIONS.
M. CONSTRUCTION AND INSTALLATIONS SHALL CONFORM TO ALL
FEDERAL, STATE LOCAL ORDINANCES, CODES, ETC.
N. ALL FIRE-RATED ASSEMBLIES WITH RECESSED WALL ACCESSORIES
AND/OR PENETRATIONS I.E. RECEPTACLES, CONDUITS, DUCTS, PIPING,
FIRE EXTINGUISHER CABINETS, PAPER TOWEL DISPENSERS. ETC.
SHALL BE CONSTRUCTED TO MAINTAIN THE DESIGNATED ASSEMBLY
RATING.
O. ALL SOUND, SMOKE OR FIRE RATED WALLS SHALL EXTEND FROM
FLOOR SUBSTRATE TO THE UNDERSIDE OF FLOOR OR ROOF DECK
ABOVE AND SHALL BE FULLY FIRE-SAFE AND SEALED AS REQUIRED TO
PROVIDE THE ASSEMBLY RATING DESIGNATED.
P. ALL PENETRATIONS THROUGH FLOORS, CHASED, SHAFTS AND FIRE
RATED ASSEMBLIES SHALL BE FIRE-STOPPED.
Q. INSTALL MINERAL WOOL INSULATION IN ALL EXPANSION JOINTS
THROUGH THE FLOOR AND ROOF SLABS, CONTINUOUS. PROVIDE FIRE-
RATED EXPANSION JOINTS WITH RATED SAFING INSULATION BLANKET
AT ALL RATED ASSEMBLIES.
R. ALL GRADES SHOWN IN SECTION(S) ARE DIAGRAMMATIC.
CONTRACTOR SHALL VERIFY AND COORDINATE GRADES WITH CIVIL
DRAWINGS.
S. CONTRACTOR SHALL CAULK ALL DISSIMILAR MATERIALS (ie. DRYWALL, STOREFRONT.
T. PROVIDE CONTROL JOINTS IN PARTITIONS @ 30'-0" MAX OR AS
INDICATED ON DRAWINGS.
U. COORDINATE ALL EXTERIOR WALKWAYS WITH CIVIL DRAWINGS.
NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
FLOOR PLAN REFERENCE NOTES:
NEW STOREFRONT DOORS. SEE DOOR SCHEDULE AND
DOOR TYPE ELEVATION.
FUTURE RECEPTION DESK.
NEW VANITY. SEE ELEVATION. SEE PLUMBING SHEETS.
MANICURE EQUIPMENT BY OTHERS.
PEDICURE EQUIPMENT BY OTHERS.
STYLING STATIONS BY OTHERS.
SHAMPOO SINKS. SEE PLUMBING.
FACIAL BEDS BY OTHERS.
WASHER/DRYER BY OTHERS.
PROVIDE BLOCKING IN WALL FOR OWNER FURNISHED
EQUIPMENT.
BATTERY POWERED ADA ACCESS PADDLE.
REMOVE & REPLACE CMU WALL AS REQUIRED FOR MEP
WORK.
MIRROR, 24X36. VERIFY MOUNTING HEIGHT W/OWNER PRIOR
TO INSTALLATION.
FIRE EXTINGUISHER CABINET.
NEW RESILIENT BASE - RB01.
NEW RESILIENT FLOORING - VCT01.
EXISTING FLOORING TO REMAIN.
TRANSITION STRIP AS REQUIRED.
NO WORK THIS AREA
FIELD VERIFY
+/- 41' - 8"
FINISHED EDGE
NO WORK THIS AREA
A1.2
A1.2
A1.2
COSMETOLOGY
NE2-5
OFFICE
NE2-4
LOCKERS
NE2-3
CLASSROOM
NE2-2
STORAGE
NE2-1
TYP OF 9
13TYP OF 3
13TYP OF 13
A1.2
G3.B.2
6 5/8"
A1.2
G3.B.1
/8
9' - 10"
+/- 7' - 0"
4 44
5 5 5 5
6 6
6666 6 6
A1.2
G6.A.1
G6.A.1
A1.2
G3.A.2
NO WORK THIS AREA
NO WORK THIS AREA
COSMETOLOGY
NW1-6
STORAGE
NW1-11
ELEC
NW1-12C
FACIALS
NW1-12A
WASHER
NW1-12B
TYP OF
13TYP OF
VCT01
VCT01
VCT01
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
DRAWN BY
A&E FILE NO. 2312-353
DECA LOG #
ACCOUNT NO.
470 CB9H WK 5800
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
03/05/2024
03/05/24
KCTCS - Renovate Cosmetology - West KY CTC
ARCHITECTURAL FLOOR PLANS
A1.1
LJ
ER
ER
1/8" = 1'-0"
SECOND FLOOR COSMETOLOGY
1/8" = 1'-0"
FIRST FLOOR COSMETOLOGY
2'0' 4' 8'
1/8''=1'-0''
North
2'0' 4' 8'
1/8''=1'-0''
North
MATERIAL FINISH LEGEND
064116
PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
PL01 MFG: WILSONART
COLOR: WALNUT HEIGHTS
NMBR: 7965K-12
PLASTIC LAMINATE
096513
RESILIENT BASE AND ACCESSORIES
RB01 MFG: TARKETT
STYLE: TRADITIONAL
PROFILE: COVE W/ TOE
HEIGHT: 4"
COLOR: MATCH EXISTING
RUBBER WALL BASE
096519
RESILIENT TILE FLOORING
VCT01 MFG: ARMSTRONG FLOORING
STYLE: STANDARD EXCELON
COLOR: MATCH EXISTING
SIZE: 12" x 12"
VINYL COMPOSITE TILE
FLOORING
123661.16
SOLID SURFACING COUNTERTOPS
SS01 MFG: CORIAN
COLOR: CAMEO WHITE
SOLID SURFACE
ADDENDUM 001 - 04/02/2024
HW SET #1 - Exterior Storefont
Quantity Hardware Model Finish Manufacturer
6 Hinges BB1168 US26D Hager 2 Exit Device 9947 QEL US26D Von Duprin 2 EPT EPT-10 689 Von Duprin 1 Power Supply PS902-2RS Von Duprin 1 Cylinder 12-E72 626 Best/Stanley 2 Pulls RM3311 (36" L) US32 Rockwood 1 *Closer M-Force 626 Stanley 1 Closer* 4040XP 689 LCN 1 Threshold 425HD US27 National Guard 1/Set Weatherstrip 5050C Black National Guard
*Note
LCN CLOSER ON LEFT LEAF, MAGIC FORCE TO BE USED ON RIGHT LEAF.
HW SET #2
Quantity Hardware Model Finish Manufacturer
4 Hinges BB1168 US26D Hager 1 Storeroom 9K3-7D 15D-S3 626 Stanley 1 Stops 236W/241F US26D Hager 1 Silencer 308D Hager
2' - 1"
SOLID SURFACE
COUNTERTOP WITH
EASED EDGES AND
BACKSPLASH
2x4 WOOD BLOCKING
3/4" PLASTIC
LAM. CLAD
DOOR
DOOR
PULL
3/4"
FIXED
PANEL
BASE
S E
E E
L E
V A
T
IO
N
/2
3/4" PLASTIC LAM.
CLAD BASE
CASEWORK TYPE : "LE" w/ SINK
3/4" PLYWOOD
SUBSTRATE
SEALANT ALONG
PERIMETER
WOOD BLOCKING
1/2" PLAS. LAM. CLAD BACK
3"
SCHEDULE
SEE
S C
H E
D U
L E
S E
E
"F"
FLUSH PANEL
SCHEDULE
SEE
S C
H E
D U
L E
S E
E
/2
5 1/2" 5 1/2"
1/4" TEMP. GLASS
"AG"
ALIGN W/
PANIC BAR
ALUM GLASS
(ALUM WIDE STYLE)
1/4" TEMP. GLASS
S E
E S
C H
E D
U L E
2"2"
SEE SCHEDULE
F1 F2
S E
E S
C H
E D
U L E
6' - 4"
2" 2"
SOLID SURFACE
COUNTERTOP WITH
EASED EDGES AND
BACKSPLASH
SEALANT ALONG
PERIMETER
RAKKS METAL SUPPORT
BRACKET @ 4'-0" O.C.
CLEAR ANONDIZED.
WALL BASE
3/4" PLYWOOD
SUBSTRATE
24X36 MIRROR
SOUND
ATTENUATION
INSULATION TO DECK
EXISTING WALL
CONSTRUCTION
NEW BASE
4 1/4"
EXISTING SUSPENDED
ACOUSTICAL
CEILING. REWORK AS
NEEDED FOR NEW WALL
CONSTRUCTION.
NEW 5/8" TYPE "X"
GYPSUM BOARD
THIS SIDE ONLY TO
DECK
109' - 3 1/2"
EXISTING WALL
HEIGHT
NEW 3 5/8" METAL
STUDS @ 16" O.C. TO
DECK
5/8" TYPE "X"
GYPSUM BOARD
3 5/8" METAL STUD
@16" O.C.
SOUND
ATTENUATION
INSULATION
EXISTING
E X
IS
T
IN
G
SS01
FINISHED EDGE
PL01
/2
/2
1"
30LE
ABBREVIATIONS:
AL ALUMINUM
GL 1/2" TEMPERED GLASS
HM HOLLOW METAL
WD SOLID CORE WOOD - ACROVYN DOOR
TEMP TEMPERED GLASS
SO SOLID SURFACE
ETR EXISTING TO REMAIN
H.O. MAGNETIC HOLD OPEN
IT INSULATED TEMPERED GLASS
SEE SCHEDULE
SEE PLAN
LINE OF INTERSECTING
WALL (TYPICAL WHERE
OCCURS)
FRAME ANCHOR -
MINIMUM 3 PER
JAMB
HOLLOW
METAL FRAME
JOINT SEALANT
(BOTH SIDES)
METAL STUDS
@ 16" O.C.
5/8" TYPE "X GYPSUM
BOARD
SOUND
ATTENUATION
INSULATION
T Y
P E
S
S E
E F
R A
M E
SEE PLAN
5/8" TYPE "X"
GYPSUM BOARD
18 GA. BOX HEADER
JOINT SEALANT
(BOTH SIDES)
HOLLOW METAL FRAME
SEE SCHEDULE
SOUND ATTENUATION
INSULATION
20 GA. METAL STUDS
EXISTING CONSTRUCTION
BACKER ROD AND
SEALANT
ALUM FRAME
MAGIC
FORCE
OPERATOR
AND HEADER
ACCESS COVER
5 1/2"
DOOR ARM
CONCEALING CHANNEL
NEW DOOR
TRACK
E X
IS
T
IN
G
C O
N S
T R
U C
T
IO
N
ALUM FRAME
BACKER ROD AND SEALANT
INSTALL TREATED 2X
LUMBER W/ BOND BREAKER
NEW DOOR
SOLID SURFACE
COUNTERTOP WITH
EASED EDGES AND
BACKSPLASH
SEALANT ALONG
PERIMETER
RAKKS METAL SUPPORT
BRACKET @ 4'-0" O.C.
CLEAR ANONDIZED.
WALL BASE
3/4" PLYWOOD
SUBSTRATE
24X36 MIRROR.
BOTTOM OF
REFLECTIVE SURFACE
TO NOT BE HIGHER
THAN 40 INCHES FROM
FINISHED FLOOR.
DRAWING INFORMATION
CHECKED BY
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS BUILT DATE
MM/DD/YR
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
DESCRIPTION OF REVISIONS DATE
RTA DATE
DRAWN BY
A&E FILE NO. 2312-353
DECA LOG #
ACCOUNT NO.
470 CB9H WK 5800
DESCRIPTION OF REVISIONS DATE
DESIGNED BY
03/05/2024
03/05/24
KCTCS - Renovate Cosmetology - West KY CTC
DOOR SCHEDULE AND DETAILS
A1.2
LJ
ER
ER
DOOR SCHEDULE
Door Number
Door Data Frame Data
Hardware Set Comments Door
NumberFire Rating Door Type Material Width Height Thickness Glass Type Material Depth Head Jamb
11 - - AG ALUM PR 3' - 0" 7' - 2" 1 3/4" TEMP F2 ALUM 4 1/2" AL1 AL1 #1 11
12 - - F WD 3' - 0" 7' - 0" 1 3/4" F1 HM 4 1/2" HM1 HM1 #2 12
3/4" = 1'-0"
STANDARD CASEWORK SECTION
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
FRAME TYPES
3/4" = 1'-0"
WALL SECTION
1/2" = 1'-0"
WALL SECTION
3/4" = 1'-0"
PLAN DETAIL
3/8" = 1'-0"
INTERIOR ELEVATION
3" = 1'-0"
HM1 - JAMB DETAIL
3" = 1'-0"
HM1 - HEAD DETAIL
3" = 1'-0"
AL1 - HEAD DETAIL
3" = 1'-0"
AL1 - JAMB DETAIL
3/4" = 1'-0"
ADA COUNTER SECTION
ADDENDUM 001 - 04/02/2024
| Addendum One |
| CB60 ADD 001 |
File details come from the government source that posted it. Updated .