Addendum One .pdf

PDF 413 KB Posted

Attached to
RFB-221-24 KCTCS Renovate Cosmetology West KY CTC
Solicitation number
RFB 785 2400000544 2
Issued by
Laurel County, Kentucky

About this file

This Addendum One document issued by the Commonwealth of Kentucky Department for Facilities and Support Services Division of Engineering and Contract Administration pertains to Invitation to Bid No. RFB-221-24 for the renovation of the Cosmetology program space at West Kentucky Community & Technical College (KCTCS) in Paducah, Kentucky. The addendum, dated April 2, 2024, clarifies specifications and drawing requirements for the general contractor performing the renovation work. Key clarifications include that paint specifications are not included in the project manual and painting of new walls is not required of the general contractor; Bradley model 780 24"x36" mirrors are the basis of design; Rakks bracket model EHR-1818 Clear Anodized must be used for metal support brackets with specific mounting heights referenced in revised details; and countertop heights on the south wall must be lowered to accommodate ADA compliance. The addendum also corrects a reference note numbering discrepancy on the floor plan from reference 20 to reference 17.

The addendum comprises four items and two attachments (A1.1 and A1.2) containing detailed architectural floor plans, door schedules, and construction details. The document specifies general construction requirements including patching and matching existing finishes, providing blocking for equipment installation, access panels for mechanical systems, fire-rated assembly maintenance, floor drain specifications, gypsum board installation standards, and caulking requirements for dissimilar materials. Hardware specifications for exterior storefront doors and interior doors are provided in detailed schedules with manufacturer information. The renovation addresses multiple cosmetology spaces including styling stations, shampoo sinks, manicure and pedicure areas, facial bed spaces, and support areas such as lockers, storage, and classrooms across first and second floor layouts.

View the file

Other files

File Type Posted
Final_RFB_785_2400000544_1_SO_FORM.PDF PDF
Final_RFB_785_2400000544_2_SO_FORM.PDF PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-221-24

FOR: Renovate Cosmetology West KY CTC Kentucky Community & Technical College System Paducah, Kentucky

DATE: April 3, 2024

RFB-785-2400000544

ADDENDUM NO. One (1)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.

END OF ADDENDUM

Invitation to Bid No. RFB-221-24 For: Renovate Cosmetology West KY CTC Kentucky Community & Technical College System

Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration

P a g e | 1 of 2

T000-LASTNAME-

INT

INDIANA | ILLINOIS | KENTUCKY | OHIO

haferdesign.com

ADDENDUM

Project: KCTCS – Renovate Cosmetology Addendum No.: 001

Date: April 2, 2024

Owner: KCTCS – West Kentucky Project Number: CB60

Contract for: GC

The original specifications and drawings dated 03/05/2024 for the project noted above are amended as noted in this Addendum Number 001. Receipt of this addendum and any subsequent addenda must be acknowledged on the final bid documents. This addendum consists of four (4) item(s) and two (2) attachment(s).

Attachments: A1.1, A1.2

By: Luke Johnson

CC: eComm

QUESTIONS AND ANSWERS

1-1 Q. I know we’re adding some walls in this project but I see no spec of type of paint - Can I get a spec on that please?

A. Paint specification will not be included in the project manual. General contractor is not required to paint any new walls, bulkheads, ceilings, frames, or any other item as part of their scope of work.

1-2

Q. Can you provide a spec for the 24”x36” mirrors?

A. Bradley model 780 24”x36” is the basis of design.

1-3 Q. The Rakk Metal Support Brackets – Is there a model number? Do they need to be ADA compliant?

A. Mounting heights shown on detail 4 and 5 on sheet A1.2. Provide Rakks bracket EHR-1818 Clear

Anodized, see revised detail 4/A1.2. Additionally, lower counter top height on south wall as indicated on

A1.1 and shown in new detail 5/A1.2 for ADA countertop.

1-4 Q. page A1.1 - 2nd Floor plans there seems to be a reference note box labeled 20. However in the

References, the numbers only go as far as 18. I want to make sure nothing was left off or I’m not missing something.

A. Reference note has been updated to “17”.

P a g e | 2 of 2

DN

GENERAL FLOOR PLAN NOTES:

A. TOP OF FIRST FLOOR CONCRETE SLAB ELEVATION ESTABLISHED AT

100'-0".

B. ALL DIMENSIONS ON FLOOR PLANS ARE FROM FACE OF FINISH

GYPSUM BOARD, FACE OF MASONRY, FACE OF CONCRETE OR

CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE.

C. CONTRACTOR SHALL PATCH AND MATCH EXISTING WALL FINISHES

WITH LIKE MATERIALS AND FINISHES WHERE DISTURBED BY

CONSTRUCTION.

D. CONTRACTOR SHALL PROVIDE BLOCKING IN WALLS, CEILINGS, AND

ANY OTHER LOCATION AS REQUIRED FOR INSTALLATION OF

CASEWORK, SURFACE MOUNTED ITEMS, PROJECTION SCREENS,

MARKER BOARDS, TOILET ACCESSORIES, SINK ACCESSORIES, WALL

MOUNTED DOOR STOPS, AND ANY OTHER SURFACE MOUNTED ITEMS.

E. FOR INTERIOR FINISHES REFER TO THE MATERIAL FINISH LEGEND ON

SHEET A1.1.

F. CONTRACTOR SHALL PROVIDE ACCESS PANELS IN WALLS WHERE

SERVICE TO MECHANICAL, PLUMBING, ELECTRICAL, ETC. ELEMENTS

ARE TO BE ADJUSTED I.E. CLEANOUTS, VALVES DAMPERS, ETC.

ACCESS PANELS SHALL BE OF THE SAME RATING AS THE ADJACENT

WALL CONSTRUCTION.

G. CONTRACTOR SHALL PATCH FLOORING AND WHERE WALLS BASE

HAVE BEEN REMOVED DURING DEMOLITION WITH FLOORING AND

BASE THAT MATCHES EXISTING, ADJACENT FLOOR FINISHES UNLESS

NOTED OTHERWISE.

H. REFER TO ELEVATIONS AND DETAILS FOR CLARIFICATION OF WALL

FINISH EXTENTS.

I. CONTRACTOR SHALL CAULK DOOR FRAME FROM FLOOR

CONTINUOUSLY AT THE PERIMETER OF DOOR AND WINDOW FRAMES.

CAULK AFTER WALL COVERING IS INSTALLED (IF SPECIFIED).

J. MAINTAIN FIRE RATED ASSEMBLY IN WALLS, CEILINGS. FLOORS, ETC.

PROVIDE THROUGH-PENETRATION FIRESTOP SYSTEMS AT ALL

PENETRATIONS IN FIRE-RATED ASSEMBLIES. PROVIDE FIRE-RESISTIVE

JOINT SYSTEMS AT ALL JOINTS BETWEEN FIRE-RATED ASSEMBLIES

AND ADJACENT CONSTRUCTION.

K. FLOOR DRAINS SHALL BE RECESSED 1/2" TO 3/4" (BASED ON ROOM

SIZE) UNLESS NOTED OTHERWISE. SLOPE FLOOR TO PROVIDE

POSITIVE DRAINAGE.

L. HOLD GYPSUM BOARD 1/4" FROM FLOOR, CEILING AND ANY ADJACENT

SURFACE AND PROVIDE A CONTINUOUS BEAD OF ACOUSTICAL

SEALANT AROUND PERIMETER OF ACOUSTICAL PARTITIONS ON EACH

SIDE OF THE WALL. PROVIDE ACOUSTICAL FIRE SEALANT AT FIRE-

RATED PARTITIONS.

M. CONSTRUCTION AND INSTALLATIONS SHALL CONFORM TO ALL

FEDERAL, STATE LOCAL ORDINANCES, CODES, ETC.

N. ALL FIRE-RATED ASSEMBLIES WITH RECESSED WALL ACCESSORIES

AND/OR PENETRATIONS I.E. RECEPTACLES, CONDUITS, DUCTS, PIPING,

FIRE EXTINGUISHER CABINETS, PAPER TOWEL DISPENSERS. ETC.

SHALL BE CONSTRUCTED TO MAINTAIN THE DESIGNATED ASSEMBLY

RATING.

O. ALL SOUND, SMOKE OR FIRE RATED WALLS SHALL EXTEND FROM

FLOOR SUBSTRATE TO THE UNDERSIDE OF FLOOR OR ROOF DECK

ABOVE AND SHALL BE FULLY FIRE-SAFE AND SEALED AS REQUIRED TO

PROVIDE THE ASSEMBLY RATING DESIGNATED.

P. ALL PENETRATIONS THROUGH FLOORS, CHASED, SHAFTS AND FIRE

RATED ASSEMBLIES SHALL BE FIRE-STOPPED.

Q. INSTALL MINERAL WOOL INSULATION IN ALL EXPANSION JOINTS

THROUGH THE FLOOR AND ROOF SLABS, CONTINUOUS. PROVIDE FIRE-

RATED EXPANSION JOINTS WITH RATED SAFING INSULATION BLANKET

AT ALL RATED ASSEMBLIES.

R. ALL GRADES SHOWN IN SECTION(S) ARE DIAGRAMMATIC.

CONTRACTOR SHALL VERIFY AND COORDINATE GRADES WITH CIVIL

DRAWINGS.

S. CONTRACTOR SHALL CAULK ALL DISSIMILAR MATERIALS (ie. DRYWALL, STOREFRONT.

T. PROVIDE CONTROL JOINTS IN PARTITIONS @ 30'-0" MAX OR AS

INDICATED ON DRAWINGS.

U. COORDINATE ALL EXTERIOR WALKWAYS WITH CIVIL DRAWINGS.

NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE FOUND.

FLOOR PLAN REFERENCE NOTES:

NEW STOREFRONT DOORS. SEE DOOR SCHEDULE AND

DOOR TYPE ELEVATION.

FUTURE RECEPTION DESK.

NEW VANITY. SEE ELEVATION. SEE PLUMBING SHEETS.

MANICURE EQUIPMENT BY OTHERS.

PEDICURE EQUIPMENT BY OTHERS.

STYLING STATIONS BY OTHERS.

SHAMPOO SINKS. SEE PLUMBING.

FACIAL BEDS BY OTHERS.

WASHER/DRYER BY OTHERS.

PROVIDE BLOCKING IN WALL FOR OWNER FURNISHED

EQUIPMENT.

BATTERY POWERED ADA ACCESS PADDLE.

REMOVE & REPLACE CMU WALL AS REQUIRED FOR MEP

WORK.

MIRROR, 24X36. VERIFY MOUNTING HEIGHT W/OWNER PRIOR

TO INSTALLATION.

FIRE EXTINGUISHER CABINET.

NEW RESILIENT BASE - RB01.

NEW RESILIENT FLOORING - VCT01.

EXISTING FLOORING TO REMAIN.

TRANSITION STRIP AS REQUIRED.

NO WORK THIS AREA

FIELD VERIFY

+/- 41' - 8"

FINISHED EDGE

NO WORK THIS AREA

A1.2

A1.2

A1.2

COSMETOLOGY

NE2-5

OFFICE

NE2-4

LOCKERS

NE2-3

CLASSROOM

NE2-2

STORAGE

NE2-1

TYP OF 9

13TYP OF 3

13TYP OF 13

A1.2

G3.B.2

6 5/8"

A1.2

G3.B.1

/8

9' - 10"

+/- 7' - 0"

4 44

5 5 5 5

6 6

6666 6 6

A1.2

G6.A.1

G6.A.1

A1.2

G3.A.2

NO WORK THIS AREA

NO WORK THIS AREA

COSMETOLOGY

NW1-6

STORAGE

NW1-11

ELEC

NW1-12C

FACIALS

NW1-12A

WASHER

NW1-12B

TYP OF

13TYP OF

VCT01

VCT01

VCT01

DRAWING INFORMATION

CHECKED BY

REVISION HISTORY OF THIS DRAWING

DRAWING NO.

AS BUILT DATE

MM/DD/YR

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

DESCRIPTION OF REVISIONS DATE

RTA DATE

DRAWN BY

A&E FILE NO. 2312-353

DECA LOG #

ACCOUNT NO.

470 CB9H WK 5800

DESCRIPTION OF REVISIONS DATE

DESIGNED BY

03/05/2024

03/05/24

KCTCS - Renovate Cosmetology - West KY CTC

ARCHITECTURAL FLOOR PLANS

A1.1

LJ

ER

ER

1/8" = 1'-0"

SECOND FLOOR COSMETOLOGY

1/8" = 1'-0"

FIRST FLOOR COSMETOLOGY

2'0' 4' 8'

1/8''=1'-0''

North

2'0' 4' 8'

1/8''=1'-0''

North

MATERIAL FINISH LEGEND

064116

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

PL01 MFG: WILSONART

COLOR: WALNUT HEIGHTS

NMBR: 7965K-12

PLASTIC LAMINATE

096513

RESILIENT BASE AND ACCESSORIES

RB01 MFG: TARKETT

STYLE: TRADITIONAL

PROFILE: COVE W/ TOE

HEIGHT: 4"

COLOR: MATCH EXISTING

RUBBER WALL BASE

096519

RESILIENT TILE FLOORING

VCT01 MFG: ARMSTRONG FLOORING

STYLE: STANDARD EXCELON

COLOR: MATCH EXISTING

SIZE: 12" x 12"

VINYL COMPOSITE TILE

FLOORING

123661.16

SOLID SURFACING COUNTERTOPS

SS01 MFG: CORIAN

COLOR: CAMEO WHITE

SOLID SURFACE

ADDENDUM 001 - 04/02/2024

HW SET #1 - Exterior Storefont

Quantity Hardware Model Finish Manufacturer

6 Hinges BB1168 US26D Hager 2 Exit Device 9947 QEL US26D Von Duprin 2 EPT EPT-10 689 Von Duprin 1 Power Supply PS902-2RS Von Duprin 1 Cylinder 12-E72 626 Best/Stanley 2 Pulls RM3311 (36" L) US32 Rockwood 1 *Closer M-Force 626 Stanley 1 Closer* 4040XP 689 LCN 1 Threshold 425HD US27 National Guard 1/Set Weatherstrip 5050C Black National Guard

*Note

LCN CLOSER ON LEFT LEAF, MAGIC FORCE TO BE USED ON RIGHT LEAF.

HW SET #2

Quantity Hardware Model Finish Manufacturer

4 Hinges BB1168 US26D Hager 1 Storeroom 9K3-7D 15D-S3 626 Stanley 1 Stops 236W/241F US26D Hager 1 Silencer 308D Hager

2' - 1"

SOLID SURFACE

COUNTERTOP WITH

EASED EDGES AND

BACKSPLASH

2x4 WOOD BLOCKING

3/4" PLASTIC

LAM. CLAD

DOOR

DOOR

PULL

3/4"

FIXED

PANEL

BASE

S E

E E

L E

V A

T

IO

N

/2

3/4" PLASTIC LAM.

CLAD BASE

CASEWORK TYPE : "LE" w/ SINK

3/4" PLYWOOD

SUBSTRATE

SEALANT ALONG

PERIMETER

WOOD BLOCKING

1/2" PLAS. LAM. CLAD BACK

3"

SCHEDULE

SEE

S C

H E

D U

L E

S E

E

"F"

FLUSH PANEL

SCHEDULE

SEE

S C

H E

D U

L E

S E

E

/2

5 1/2" 5 1/2"

1/4" TEMP. GLASS

"AG"

ALIGN W/

PANIC BAR

ALUM GLASS

(ALUM WIDE STYLE)

1/4" TEMP. GLASS

S E

E S

C H

E D

U L E

2"2"

SEE SCHEDULE

F1 F2

S E

E S

C H

E D

U L E

6' - 4"

2" 2"

SOLID SURFACE

COUNTERTOP WITH

EASED EDGES AND

BACKSPLASH

SEALANT ALONG

PERIMETER

RAKKS METAL SUPPORT

BRACKET @ 4'-0" O.C.

CLEAR ANONDIZED.

WALL BASE

3/4" PLYWOOD

SUBSTRATE

24X36 MIRROR

SOUND

ATTENUATION

INSULATION TO DECK

EXISTING WALL

CONSTRUCTION

NEW BASE

4 1/4"

EXISTING SUSPENDED

ACOUSTICAL

CEILING. REWORK AS

NEEDED FOR NEW WALL

CONSTRUCTION.

NEW 5/8" TYPE "X"

GYPSUM BOARD

THIS SIDE ONLY TO

DECK

109' - 3 1/2"

EXISTING WALL

HEIGHT

NEW 3 5/8" METAL

STUDS @ 16" O.C. TO

DECK

5/8" TYPE "X"

GYPSUM BOARD

3 5/8" METAL STUD

@16" O.C.

SOUND

ATTENUATION

INSULATION

EXISTING

E X

IS

T

IN

G

SS01

FINISHED EDGE

PL01

/2

/2

1"

30LE

ABBREVIATIONS:

AL ALUMINUM

GL 1/2" TEMPERED GLASS

HM HOLLOW METAL

WD SOLID CORE WOOD - ACROVYN DOOR

TEMP TEMPERED GLASS

SO SOLID SURFACE

ETR EXISTING TO REMAIN

H.O. MAGNETIC HOLD OPEN

IT INSULATED TEMPERED GLASS

SEE SCHEDULE

SEE PLAN

LINE OF INTERSECTING

WALL (TYPICAL WHERE

OCCURS)

FRAME ANCHOR -

MINIMUM 3 PER

JAMB

HOLLOW

METAL FRAME

JOINT SEALANT

(BOTH SIDES)

METAL STUDS

@ 16" O.C.

5/8" TYPE "X GYPSUM

BOARD

SOUND

ATTENUATION

INSULATION

T Y

P E

S

S E

E F

R A

M E

SEE PLAN

5/8" TYPE "X"

GYPSUM BOARD

18 GA. BOX HEADER

JOINT SEALANT

(BOTH SIDES)

HOLLOW METAL FRAME

SEE SCHEDULE

SOUND ATTENUATION

INSULATION

20 GA. METAL STUDS

EXISTING CONSTRUCTION

BACKER ROD AND

SEALANT

ALUM FRAME

MAGIC

FORCE

OPERATOR

AND HEADER

ACCESS COVER

5 1/2"

DOOR ARM

CONCEALING CHANNEL

NEW DOOR

TRACK

E X

IS

T

IN

G

C O

N S

T R

U C

T

IO

N

ALUM FRAME

BACKER ROD AND SEALANT

INSTALL TREATED 2X

LUMBER W/ BOND BREAKER

NEW DOOR

SOLID SURFACE

COUNTERTOP WITH

EASED EDGES AND

BACKSPLASH

SEALANT ALONG

PERIMETER

RAKKS METAL SUPPORT

BRACKET @ 4'-0" O.C.

CLEAR ANONDIZED.

WALL BASE

3/4" PLYWOOD

SUBSTRATE

24X36 MIRROR.

BOTTOM OF

REFLECTIVE SURFACE

TO NOT BE HIGHER

THAN 40 INCHES FROM

FINISHED FLOOR.

DRAWING INFORMATION

CHECKED BY

REVISION HISTORY OF THIS DRAWING

DRAWING NO.

AS BUILT DATE

MM/DD/YR

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

DESCRIPTION OF REVISIONS DATE

RTA DATE

DRAWN BY

A&E FILE NO. 2312-353

DECA LOG #

ACCOUNT NO.

470 CB9H WK 5800

DESCRIPTION OF REVISIONS DATE

DESIGNED BY

03/05/2024

03/05/24

KCTCS - Renovate Cosmetology - West KY CTC

DOOR SCHEDULE AND DETAILS

A1.2

LJ

ER

ER

DOOR SCHEDULE

Door Number

Door Data Frame Data

Hardware Set Comments Door

NumberFire Rating Door Type Material Width Height Thickness Glass Type Material Depth Head Jamb

11 - - AG ALUM PR 3' - 0" 7' - 2" 1 3/4" TEMP F2 ALUM 4 1/2" AL1 AL1 #1 11

12 - - F WD 3' - 0" 7' - 0" 1 3/4" F1 HM 4 1/2" HM1 HM1 #2 12

3/4" = 1'-0"

STANDARD CASEWORK SECTION

1/4" = 1'-0"

DOOR TYPES

1/4" = 1'-0"

FRAME TYPES

3/4" = 1'-0"

WALL SECTION

1/2" = 1'-0"

WALL SECTION

3/4" = 1'-0"

PLAN DETAIL

3/8" = 1'-0"

INTERIOR ELEVATION

3" = 1'-0"

HM1 - JAMB DETAIL

3" = 1'-0"

HM1 - HEAD DETAIL

3" = 1'-0"

AL1 - HEAD DETAIL

3" = 1'-0"

AL1 - JAMB DETAIL

3/4" = 1'-0"

ADA COUNTER SECTION

ADDENDUM 001 - 04/02/2024

Addendum One
CB60 ADD 001