This is Addendum One to Invitation to Bid No. RFB-242-24 issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration, for the Department of Juvenile Justice Northern Kentucky Youth Development Center (NKYDC) Shower Renovation project located in Crittenden, Kentucky. The addendum was issued on May 9, 2024, and contains specification changes and drawing modifications that bidders must incorporate into their proposals. A pre-bid meeting was held with attendees representing Westech Environmental, BR Systems, DECA (Project Manager), NKYDC Maintenance, Yeiser Structural, KFI Engineers, and Kersey and Kersey Architects. Background checks are not required for workers on site. The project is phased, with the West Shower designated as Phase 1 work and the East Shower as Phase 2 work.
Key technical modifications specified in the addendum include updated plumbing coordination requirements to maintain at least one bathroom operational at all times during construction, with final connections to occur during unoccupied periods. The general sheet note requires contractors to coordinate with the facility owner to minimize service outages and field verify all existing sanitary waste, vent, domestic hot water, and domestic cold water piping connections. A thermostatic mixing valve (LEONARD LV-982-LF, 13 GPM at 15 PSI pressure drop, lead-free) must be installed per manufacturer recommendations with maintained access through existing access panels. All lighting fixtures must be provided with universal or multi-volt drivers. Since the building was constructed in the 1970s and no environmental report has been completed, the Commonwealth's "Hazardous Material Construction Guidelines" document will be issued and reviewed during the pre-construction meeting to address potential hazardous material encounters.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_RFB_785_2400000574_1_SO_FORM.PDF | ||
| Final_RFB_785_2400000574_2_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-242-24
FOR: Department of Juvenile Justice Northern Kentucky Youth Development Center (NKYDC) Shower Renovation Crittenden, Kentucky
DATE: May 9, 2024
RFB-785-2400000574
ADDENDUM NO. One (1)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-242-24 For: Department of Juvenile Justice Northern Kentucky Youth Development Center (NKYDC) Shower Renovation Crittenden, Kentucky
Amanda Greer, Statewide Procurement Analyst II Division of Engineering and Contract Administration
ADDENDUM #01 Date: 9 May 2024
COMMONWEALTH OF KENTUCKY
DJJ-Northern Kentucky Youth Development Center 15600 Turner Road Crittenden, KY
RFB – 242-24 DJJ
Architect’s Project No: 2353
TO: ALL BIDDERS AND PROSPECTIVE BIDDERS
Gentlemen/Ladies:
The following changes in, additions to, or deletions from the Drawings and Specifications of the above-named project shall be a part of the Contract. Each bidder shall govern himself or herself accordingly in the preparation of his or her proposal.
RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED ON YOUR BID FORM
GENERAL
1. A pre-bid sign in sheet is not available. The Pre-Bid Attendees:
- Geremy Holloway - Westech Environmental 513-203-3190 geremy@westech.com
- Jake Dressman - BR Systems Attending for Luke Dressman - 859-250-8144 luke.dressman@buildingrepair.systems
- Greg Schenck - DECA Project Manager
- Brian Bowling - NKYDC Maintenance
- Clay Gatewood - Yeiser Structural
- Chris Keath - KFI Engineers
- Cheryl Kersey - Kersey and Kersey Architects
2. Background checks will NOT be required for those working on site.
3. There has been no environmental report completed for the facility. The building was built in the 1970’s.
The Commonwealth of Kentucky has a “Hazardous Material Construction Guidelines” document that outlines guidelines and procedures if Hazardous Material is encountered during construction. This document will be issued and reviewed during the pre-construction meeting.
4. All lighting fixtures are to be provided with universal or multi-volt drivers.
DRAWINGS
All plumbing sheets:
1. Change “General Sheet Note” to read: “COORDINATE WITH OWNER TO MINIMIZE OUTAGES
DURING SHOWER USE TIMES. ONE BATHROOM TO BE OPERATIONAL AT ALL TIMES WHEN
POSSIBLE. COORDINATE WITH OWNER AND MAKE FINAL PLUMBING CONNECTIONS DURING
UNOCCUPIED PERIODS.”
2. Add general sheet note reading: “CONTRACTOR TO FIELD VERIFY EXISTING SANITARY WASTE, VENT, DOMESTIC HOT WATER, AND/OR DOMESTIC COLD WATER PIPING CONNECTIONS TO
PLUMBING FIXTURES. MAINTAIN CONNECTION TO ALL EXISTING FIXTURES TO REMAIN.”
mailto:geremy@westech.com mailto:luke.dressman@buildingrepair.systems
Sheet M210:
1. Add annotation showing phasing. West Shower shall be Phase 1 work; East Shower shall be Phase 2 work.
2. Add note on Underfloor Plumbing New Work Plan reading: “COORDINATE WITH OWNER FOR
OUTAGE TO BUILDING FOR SANITARY WASTE IN THESE AREAS.”
Sheet M211:
1. Update Coded Note 16 to read: “THERMOSTATIC MIXING VALVE (TMV-1): LEONARD LV-982-LF, 13
GPM AT 15 PSI PRESSURE DROP, LEAD FREE. INSTALL PER MANUFACTURER’S
RECOMMENDATIONS. MAINTAIN ACCESS TO MIXING VALVE, ASSOCIATED ISOLATION
VALVES, AND PIPING THROUGH EXISTING ACCESS PANEL.”
2. Add text note at existing water fountain to read: “RECONNECT WATER PIPING TO EXISTING
FOUNTAIN AS REQUIRED (TYPICAL OF 2).”
3. Add text note at new 2” Domestic Hot Water piping to read: “REPLACEMENT OF DHW FALLS UNDER
PHASE 1.”
4. Add text note at existing isolation rooms to read: “FIELD VERIFY CONNECTIONS TO EXISTING
PLUMBING FIXTURES IN ISOLATION ROOMS. MAINTAIN CONNECTIONS TO ALL EXISTING
FIXTURES TO REMAIN (TYPICAL).”
5. Showed two existing domestic cold water lines and isolation valves to remain, and noted re-connection for new water closets.
Sheet M510:
1. Hid plumbing fixture bodies from riser for visibility.
2. Showed new domestic cold water connections for existing water fountains.
3. Added Coded Note 14 at each existing water fountain to read: “EXISTING WATER FOUNTAIN TO
REMAIN. RECONNECT NEW DOMESTIC COLD WATER PIPING TO EXISTING FIXTURE AS
REQUIRED.”
4. HCR-1D, HCR-1N: Showed two existing domestic cold water lines and isolation valves to remain, and noted re-connection for new water closets.
5. Added Mixing Valve Schematic Piping Detail.
6. Added Riser Diagram HCR-3D
END OF ADDENDUM 1
Attachments:
-Sheet M210 - Under floor plumbing plan -Sheet M211 - Level 1 plumbing plan -Sheet M510 - Domestic riser diagram
3" SAN
2" SAN
2" V
2" V
3" SAN3" SAN
2" SAN
UP TO
NEW FCO
3" SAN
2" V
2" V
2" SAN
3" SAN
3" SAN
3" SAN
3" SAN
EX.
WC
EX.
WC
EX.
WC
EX.
WC
EX.
WC
EX.
LAV
EX.
LAV
EX.
LAV
EX.
LAV
EX.
LAV
EX.
LAV
CAP
CAP
EX.
WC
CAP
(E)5" SAN
2" V
UP
2" V
UP
2" V
UP
2" V
UP
CAP
EX.
FD
EX.
FD
EX.
FD
EX.
FD
EX.
FD
EX.
2" V
2" SAN
3" S
AN
(E)3" SAN
(E)5" SAN
4" S UP 4" S UP
(E)5" SAN
(E)4" SAN
(E)5" SAN
5" SAN
3" SAN (0 FU)
3" SAN
3" SAN
(E)4" SAN (E)4" SAN
3" SAN
(E)3" SAN
2" SAN UP
TO TD-1
(TYPICAL)
PHASE 2 WORKPHASE 1 WORK
M510
EXISTING 4" VTR
TO REMAIN.
3 33
(E)5" SAN
(E)4" SAN(E)5" SAN
(E)5" SAN
(E)3" SAN
(E)5" SAN
(E)5" SAN
(E)3" SAN
EXISTING INVERT ELEVATION
APPROXIMATELY 6'-11" BELOW
EXISTING FLOOR ELEVATION
(FIELD VERIFY).
(E )3
" S
AN
NOTE:
IT IS NOT INTENDED THAT THE PLANS SHOW ALL OFFSETS IN PIPES, CONDUITS, AND DUCTS REQUIRED FOR INSTALLATION OF THE WORK. DETAILS AND SECTIONS ARE INCLUDED FOR SOME AREAS TO SHOW INTENDED RELATIONSHIP OF THE WORK OF VARIOUS TRADES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUB-CONTRACTORS TO COORDINATE INSTALLATION OF THE
WORK AND TO PROVIDE THE NECESSARY OFFSETS, TRANSFORMATIONS, AND FITTINGS REQUIRED. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CORRECTION CONFLICTS BETWEEN THE WORK OF VARIOUS TRADES. DETAILS AND SECTIONS ARE SHOWN FOR THE CONTRACTORS CONVENIENCE AND SHALL NOT BE CONSIDERED COMPLETE IN EVERY DETAIL.
C E N ENFO
SE
ENOIS AL
GN
I
E
AT
P R
S
T K
E
C.
CHRISTOPHER
KEATH
L I S
D RE
Y
EFO K
C
TN
U
18328
ARCHITECTSK E R S E Y A N D K E R S E Y
RTA DATE
DECA LOG #
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
DRAWING NO.
AS BUILT DATE
PHASE
DATEDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWING
DATEDESCRIPTION OF REVISIONS
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
ACCOUNT NO.
Fax 502 585 2728 kerseyandkersey.com
Louisville, KY 40204
Tel 502 583 0094
839 East Gray Street Suite 207
Lexington, KY 40507
201 West Short Street Commiskey, IN 47227
Tel 812 873 1287
9307 West 1000 North
Tel 859 303 8439
LOUISVILLE, KENTUCKY LEXINGTON, KENTUCKY MADISON, INDIANA
2343 Alexandria Drive Suite 200 Lexington, KY 40504 Tel: 859-271-3246 Email: kfi@kfi-eng.com
/7
/2
:3
:0
P M
M210
UNDERFLOOR PLUMBING PLAN
15600 TURNER ROAD CRITTENDEN, KENTUCKY 41030
DJJ-NKYDC SHOWER RENOVATION
01/31/24
RTA
02/02/24
MM/DD/YR
DPT-FUND-ACTV--XX
Author
Checker
1/4" = 1'-0"M210
1 UNDERFLOOR PLUMBING NEW WORK PLAN1/4" = 1'-0"M210
2 UNDERFLOOR PLUMBING DEMOLITION PLAN
CODED NOTES:
1 REMOVE EXISTING PIPING TO THIS POINT AND RECONNECT NEW. SEE NEW WORK PLANS AND
RISER DIAGRAM FOR NEW CONNECTION.
2 REMOVE EXISTING FLOOR DRAIN AND REMOVE ASSOCIATED SANITARY / WASTE PIPING AS
INDICATED. SEE NEW WORK PLUMBING PLANS FOR NEW WORK.
3 REMOVE EXISTING FLOOR MOUNTED TOILET. REMOVED ASSOCIATED SANITARY / WASTE
PIPING BACK TO WASTE STACK AND CAP.
4 REMOVE EXISTING FLOOR DRAIN AND REMOVE ASSOCIATED SANITARY / WASTE PIPING AS
INDICATED.
5 CONNECT TO EXISTING BELOW-SLAB SANITARY/WASTE PIPING AT THIS APPROXIMATE
LOCATION AS REQUIRED. FIELD VERIFY EXISTING PIPING DEPTH.
GENERAL SHEET NOTE:
COORDINATE WITH OWNER TO MINIMIZE OUTAGES DURING SHOWER USE TIMES. ONE BATHROOM TO BE OPERATIONAL AT ALL TIMES WHEN POSSIBLE. COORDINATE WITH OWNER AND MAKE FINAL PLUMBING
CONNECTIONS DURING UNOCCUPIED PERIODS.
CONTRACTOR TO FIELD VERIFY EXISTING SANITARY WASTE, VENT, DOMESTIC HOT AND/OR DOMESTIC COLD WATER PIPING CONNECTIONS TO PLUMBING FIXTURES. MAINTAIN CONNECTIONS TO ALL EXISTING
PLUMBING FIXTURES TO REMAIN.
COORDINATE WITH OWNER FOR OUTAGE TO
BUILDING FOR SANITARY WASTE IN THESE AREAS.
WEST SHOWER
100A
EAST SHOWER
101A
EAST TOILET
RM
WEST TOILET
RM
L-1L-1L-1L-1L-1L-1 U-1 U-1
WC-1
WC-1
FD-1FD-1FD-1FD-1
4" V
1 1/2" V
2" V 1 1/2" V
SH-1
SH-1 SH-1 SH-1 SH-1 SH-1 SH-1 SH-1 SH-1 SH-1 SH-1
SH-1
SH-1
SH-1
SH-1 SH-1 SH-1 SH-1
SH-1A
SH-1A
4" V
FD-1 FD-1
FCO
FCO
6 6
2" V
2" V DN
EXISTING 24x24
ACCESS DOOR
(TYPICAL)
8 8
3" V
PHASE 2 WORKPHASE 1 WORK
2" D
T W
3" V
TD-1 TD-1 TD-1 TD-1 TD-1 TD-1 TD-1 TD-1 TD-1 TD-1 TD-1 TD-1
(E )2
D
C W
2" D
H W
1/
2" D
H W
TMV-1
FD-1
FD-1
EX.
4" VTR
TD-1 TD-1 TD-1 TD-1 TD-1 TD-1
1 1/2" V
2" DHW
3/4" DTW 1 1/4" DTW
1/
4" D
T W 1
1/ 4"
D T
W 2"
D T
W
1 1/4" DTW
3/4" DTW
TMV-1 10
(E)1 1/2" DCW
(E )1
/2
D
C W
(E)1 1/2" DCW
(E)2" DCW
CAP
CAP10
(E )1
/4
D
H W
FIELD VERIFY CONNECTIONS TO
EXISTING PLUMBING FIXTURES
IN ISOLATION ROOMS. MAINTAIN
CONNECTIONS TO ALL EXISTING
FIXTURES TO REMAIN (TYPICAL)
RECONNECT WATER PIPING
TO EXISTING FOUNTAIN AS
REQUIRED (TYPICAL OF 2)
REPLACEMENT OF DHW
FALLS UNDER PHASE 1
EXISTING DOMESTIC COLD
WATER PIPING AND VALVE
TO REMAIN. RECONNECT
NEW WATER CLOSET TO
PIPING.
4 4
(E)1 1/2" DCW
(E )1
/2
D
C W
(E)1 1/2" DCW
(E )1
/4
D
H W
(E)1 1/4" DHW
(E)1 1/4" DCW (E)2" DCW(E)1 1/4" DCW (E)2" DCW (E)2" DCW
(E )1
/4
D
C W
(E)1 1/4" DCW
PHASE 2 WORKPHASE 1 WORK
EXISTING DOMESTIC COLD
WATER PIPING AND VALVE
TO REMAIN. RECONNECT
NEW WATER CLOSET TO
PIPING.
1/
4"
1/
4"
(E )2
D
C W
(E
1/
4" D
H W
REFER TO RISER HCR-3D
FOR CONTINUATION.
NOTE:
IT IS NOT INTENDED THAT THE PLANS SHOW ALL OFFSETS IN PIPES, CONDUITS, AND DUCTS REQUIRED FOR INSTALLATION OF THE WORK. DETAILS AND SECTIONS ARE INCLUDED FOR SOME AREAS TO SHOW INTENDED RELATIONSHIP OF THE WORK OF VARIOUS TRADES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUB-CONTRACTORS TO COORDINATE INSTALLATION OF THE
WORK AND TO PROVIDE THE NECESSARY OFFSETS, TRANSFORMATIONS, AND FITTINGS REQUIRED. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CORRECTION CONFLICTS BETWEEN THE WORK OF VARIOUS TRADES. DETAILS AND SECTIONS ARE SHOWN FOR THE CONTRACTORS CONVENIENCE AND SHALL NOT BE CONSIDERED COMPLETE IN EVERY DETAIL.
C E N ENFO
SE
ENOIS AL
GN
I
E
AT
P R
S
T K
E
C.
CHRISTOPHER
KEATH
L I S
D RE
Y
EFO K
C
TN
U
18328
ARCHITECTSK E R S E Y A N D K E R S E Y
RTA DATE
DECA LOG #
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
DRAWING NO.
AS BUILT DATE
PHASE
DATEDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWING
DATEDESCRIPTION OF REVISIONS
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
ACCOUNT NO.
Fax 502 585 2728 kerseyandkersey.com
Louisville, KY 40204
Tel 502 583 0094
839 East Gray Street Suite 207
Lexington, KY 40507
201 West Short Street Commiskey, IN 47227
Tel 812 873 1287
9307 West 1000 North
Tel 859 303 8439
LOUISVILLE, KENTUCKY LEXINGTON, KENTUCKY MADISON, INDIANA
2343 Alexandria Drive Suite 200 Lexington, KY 40504 Tel: 859-271-3246 Email: kfi@kfi-eng.com
/7
/2
:3
:0
P M
M211
LEVEL 1 PLUMBING PLAN
15600 TURNER ROAD CRITTENDEN, KENTUCKY 41030
DJJ-NKYDC SHOWER RENOVATION
01/31/24
RTA
02/02/24
MM/DD/YR
DPT-FUND-ACTV--XX
Author
Checker
1/4" = 1'-0"M211
1 BATHROOM PLUMBING NEW WORK PLUMBING PLAN
1/4" = 1'-0"M211
2 BATHROOM PLUMBING DEMOLITION PLAN
CODED NOTES:
11 REMOVE EXISTING PLUMBING FIXTURE AND ASSOCIATED SANITARY/WASTE, VENT, DOMESTIC
HOT WATER, AND/OR DOMESTIC COLD WATER PIPING THROUGH WALL. SEE NEW WORK
PLUMBING PLANS FOR NEW WORK, REUSE EXISTING PIPING WHERE POSSIBLE.
12 REMOVE EXISTING 1-1/4" DOMESTIC HOT WATER PIPING BACK TO EXISTING 2" IN HALLWAY, APPROXIMATELY 50 FT. FROM BATHROOM, AND REPLACE WITH NEW 2" DOMESTIC HOT WATER
PIPING. SEE NEW WORK PLUMBING PLANS FOR NEW WORK.
13 EXTEND NEW 2" DOMESTIC HOT WATER PIPING ABOVE CEILING TO CONNECT INTO EXISTING 2"
PIPING APPROXIMATELY 50 FT. AWAY.
14 REMOVE EXISTING 1-1/4" DOMESTIC HOT WATER PIPING ABOVE CEILING TO THIS LOCATION AND
RECONNECT NEW.
15 REMOVE EXISTING DOMESTIC COLD WATER PIPING BACK TO MAIN. CAP AT MAIN AS REQUIRED.
16 THERMOSTATIC MIXING VALVE (TMV-1): LEONARD LV-982-LF, 13 GPM AT 15 PSI PRESSURE DROP, LEAD FREE. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. MAINTAIN ACCESS TO MIXING
VALVE, ASSOCIATED ISOLATION VALVES, AND PIPING THROUGH EXISTING ACCESS PANEL.
17 REMOVE EXISTING DOMESTIC HOT AND COLD WATER PIPING IN CHASE. SEE NEW WORK
PLUMBING PLANS AND ASSOCIATED RISER DIAGRAMS FOR RECONNECTION OF NEW AND
EXISTING FIXTURES TO NEW DOMESTIC HOT AND COLD WATER PIPING.
18 EXISTING DOMESTIC COLD WATER PIPING TO REMAIN.
19 REMOVE EXISTING FLOOR DRAIN.
CODED NOTES:
1 CONNECT NEW FIXTURE TO EXISTING SANITARY / WASTE AND VENT PIPING IN THIS LOCATION AS
REQUIRED (FIELD VERIFY).
4 REMOVE EXISTING SHOWER AND REMOVE ASSOCIATED WATER PIPING AS INDICATED.
5 REMOVE EXISTING TEMPERED HOT WATER BACK TO EXISTING MIXING VALVE APPROX. 50 FT.
FROM BATHROOM WALL, APPROX. 100 FT. PIPE TOTAL. COORDINATE WITH OWNER TO MINIMIZE
OUTAGE FOR ABOVE-CEILING WORK. REMOVE EXISTING MIXING VALVE AND CAP DOMESTIC HOT
WATER AND DOMESTIC COLD WATER PIPING ABOVE CEILING AS REQUIRED. SEE NEW WORK
PLUMBING PLANS FOR NEW MIXING VALVE AND TEMPERED HOT WATER SERVING NEW
SHOWERS.
6 18" x 24" ACCESS PANEL WITH VANDAL RESISTANT LOCKABLE COVER.
7 24" x 24" CEILING ACCESS PANEL WITH VANDAL RESISTANT LOCKABLE COVER.
8 8" x 8" ACCESS PANEL WITH VANDAL RESISTANT LOCKABLE COVER.
9 RECONNECT TO EXISTING 4" VENT INSIDE CHASE AT THIS APPROXIMATE LOCATION. MAINTAIN
VENT CONNECTION TO ALL EXISTING AND NEW FIXTURES. FIELD VERIFY EXISTING 4" VENT
THROUGH ROOF AND REUSE IF POSSIBLE.
10 1-1/4" DOMESTIC HOT WATER, 1-1/4" DOMESTIC COLD WATER, AND 2" TEMPERED WATER PIPING
TO/FROM NEW THERMOSTATIC MIXING VALVE SERVING NEW SHOWERS.
FIXTURE SCHEDULE AND ROUGHING-IN REQUIREMENTS
WALL HUNG
WALL HUNG,
FLOOR MOUNTED,
COUNTERTOP
INSTALL WITH A ZURN ZN1209-N4B NARROW
WALL SUPPORT SYSTEM. SEE
ARCHITECTURAL DETAILS. PROVIDE FLUSH
VALVE ACCESS THROUGH ACCESS PANEL,
COORDINATE WITH ARCHITECTURAL PLANS.
WATER CLOSET
FIXTURE
NUMBER
WC-1
REMARKS
MOUNTING
HEIGHT
MOUNTINGFIXTURE HOT COLD WASTE
(MIN.)
VENT
(MIN.)
--- 1" 4" 2"
ACCESSORIES
ACORN,1675-W-1-1.6 GPF-FV-
ADA, WALL-MOUNTED BLOWOUT
JET TOILET, TOP SUPPLY, 1.6
GPF, TYPE 304 STAINLESS
STEEL FOR 5-3/4" BLOCK WALL.
MANUFACTURER AND MODEL NO. FLUSH VALVE, FAUCET
HIGH POLISH INTEGRAL
SEAT
CONCEALED MECHANICAL
FLUSH VALVE INCLUDED IN
SINK KIT.
L-1 1/2" 1/2" 1-1/2"LAVATORY P-TRAP, STOPS &
SUPPLIES, CHROME
PLATED.
1-1/4"
P-TRAP
SECURITY FAUCET,
INCLUDED WITH SINK KIT.
ADA
SEE ARCH.
DWGS.
SEE ARCHITECTURAL DETAILS.
SHOWER FLOOR/WALL 1/2" 1/2"STANDARD 2" FDTRENCH DRAIN. SH-1 SEE REMARKS 1-1/2"
18" FROM
FLOOR TO TOP
OF SEAT.
ACORN PENAL-WARE 1652FALRB-
DMB-BP-04-M, WALL-MOUNTED
LAVATORY WITH SECURITY FRONT
ACCESS, DECK-MOUNTED BUBBLER,
HOT & COLD PNEUMATIC VALVE,
TYPE 304 STAINLESS STEEL FOR
5-3/4" BLOCK WALL.
WALL HUNG SEE REMARKS
RESIN SHOWER (SEE
ARCHITECTURAL PLANS FOR
DETAILS).
SHOWER FLOOR/WALL 1/2" 1/2"CENTER DRAIN. ADA HAND
HELD SHOWER, TAMPER
RESISTANT.
ADA 2" FDACORN SHOWER-WARE
450BBF-8-T-P, SURFACE-
MOUNTED SECURITY
SHOWERHEAD AND
CONTROLS, WITH T/P
BALANCING MIXING VALVE
LIGATURE RESISTANT, TOP
SUPPLY, WITH PENAL
SHOWERHEAD LIGATURE
RESISTANT TAMPER
RESISTANT, 1.6 GPM
SH-1A SEE REMARKS 1-1/2"RESIN SHOWER (SEE
ARCHITECTURAL PLANS FOR
DETAILS).
WALL HUNG CONTINUOUS FLUSHING RIM. INSTALL WITH A
ZURN ZN1209-N4B NARROW WALL SUPPORT
SYSTEM. SEE ARCHITECTURAL DETAILS.
PROVIDE FLUSH VALVE ACCESS THROUGH
ACCESS PANEL, COORDINATE WITH
ARCHITECTURAL PLANS.
URINALU-1 --- 1" 4" 2"
ACORN, PENAL-WARE 1705-T-1-
FV-ADA-CFR, WALL-MOUNTED
BLOWOUT JET URINAL, TOP
SUPPLY, TYPE 304 STAINLESS
STEEL FOR 5-3/4" BLOCK WALL.
HIGH POLISH INTEGRAL
SEAT
ADA
ACORN SHOWER-WARE
450B-8-T-P, SURFACE-
MOUNTED SECURITY
SHOWERHEAD AND
CONTROLS, WITH T/P
BALANCING MIXING VALVE
LIGATURE RESISTANT, TOP
SUPPLY, WITH PENAL
SHOWERHEAD LIGATURE
RESISTANT TAMPER
RESISTANT, 1.6 GPM
REFERENCE ARCHITECTURAL DETAILS FOR
MOUNTING HEIGHTS.
REFERENCE ARCHITECTURAL DETAILS FOR
MOUNTING HEIGHTS.
CONCEALED MECHANICAL
FLUSH VALVE INCLUDED IN
SINK KIT.
FLOOR DRAIN SCHEDULE
REMARKS:
1 8" DIAMETER STRAINER, 4" DIAMETER FLOOR DRAIN.
REMARKSTOPBODYMODEL NO.MANUFACTURERTYPE
BRONZE(DURA-COATED)
NICKELCAST IRONZN-415ZURNFD-1
STEELLINER-38"
STAINLESSSTAINLESS STEELZS880-38ZURNTD-1
GENERAL SHEET NOTE:
COORDINATE WITH OWNER TO MINIMIZE OUTAGES DURING SHOWER USE TIMES. ONE BATHROOM TO BE OPERATIONAL AT ALL TIMES. COORDINATE WITH OWNER TO MAKE FINAL PLUMBING CONNECTIONS
DURING UNOCCUPIED PERIODS.
GENERAL SHEET NOTE:
COORDINATE WITH OWNER TO MINIMIZE OUTAGES DURING SHOWER USE TIMES. ONE BATHROOM TO BE OPERATIONAL AT ALL TIMES WHEN POSSIBLE. COORDINATE WITH OWNER AND MAKE FINAL PLUMBING
CONNECTIONS DURING UNOCCUPIED PERIODS.
CONTRACTOR TO FIELD VERIFY EXISTING SANITARY WASTE, VENT, DOMESTIC HOT AND/OR DOMESTIC COLD WATER PIPING CONNECTIONS TO PLUMBING FIXTURES. MAINTAIN CONNECTIONS TO ALL EXISTING
PLUMBING FIXTURES TO REMAIN.
SH-1A
SH-1A
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
SH-1
FROM HCR-1N
FROM HCR-1N
3/ 4"
D T
W
2" DTW
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
2" DTW
1" D
TW
1 1/4" D
TW
3/4" D
TW 1 1/4" DTW
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
1" D
TW
1 1/4" D
TW
1" D
TW
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
3/ 4"
D T
W
1" D
TW
1 1/4" D
TW
1" D
TW
1 1/4" DTW
3/ 4"
D T
W
1 1/4" D
TW
1" D
TW
1 1/4" D
TW
1 1/4" D
TW
1 1/4" DTW
1 1/4" DTW
(E)2" DCW
(E)2" DCW
(E )1
/4
D
C W
(E )1
/4
D
C
W(E)2" DCW
(E)2" DCW
(E)1 1/4" DCW
(E)1 1/4" DCW
(E )1
/4
D
C W
(E )1
/4
D
C W
(E )1
/2
D
C W
(E)2" DCW
(E)2" DCW
(E )1
/4
D
H W
TYP.
EX. SHOWERS
EX. SHOWERS
EX. SHOWERS
EX. SHOWERS
EX. WC
EX. WC
EX. WC
EX. WC
EX. LAV
EX. LAV
EX. LAV
EX. LAV
EX. LAV
EX. UR
1"
1"
(E)1"
(E)1"
TO
HCR-2N
CAP
CAP
(E)2" DCW
(E)2" DCW
(E)2" DCW
(E)1 1/4" DCW
(E)1 1/4" DCW
(E )1
/4
D
C W
(E )1
/4
D
C W
(E )1
/4
D
C W
(E )1
/4
D
C W
(E)1 1/4" DCW
EX. WC
L-1
L-1
L-1
L-1
L-1
L-1
U-1
EX. WC
EX. WC
EX. WC
EX. WC
EX.
WC
U-1
TO
HCR-2N
2" DHW
(E)2" DCW
2" DHW(E)2" DCW
(E)2" DCW
(E )1
/4
D
C W
(E)1 1/4" DHW
(E)1 1/2" DCW
2" DTW
1 1/4" DCW
1 1/4" DHW
1 1/4" DCW
1 1/4" DHW
EX. DF
EX.
LAV
1/2" DHW
1" DCW
1 1/4" DCW
1/2" DHW
1/2" DCW
3/4" DCW
1/2" DHW
3/4" DCW
EX.
LAV
1" DHW
1 1/4" DCW
3/ 4"
D C
W
1/2" DHW
1/2" DCW
1/ 2"
D H
W (E
)1 /2
D
C W
1/2" DHW
2" DHW
(E)1 1/2" DCW
EX.
LAV
(E)1 1/2" DCW
2" DHW1 1/2" DHW
1 1/4" DHW 1 1/2" DCW
EX. DF
3/4" DCW
1" DCW
EXISTING DOMESTIC COLD
WATER PIPING AND VALVE
TO REMAIN. RECONNECT
NEW WATER CLOSET TO
PIPING.
(E )1
D
C W (E
)1
D C
W
WC-1
WC-1
NEW THERMOSTATIC MIXING
VALVE. REFER TO SHEET M211,
CODED NOTE 16. MOUNT WITH
CENTERLINE OF VALVE 54"
A.F.F.
EXISTING 24"X24"
ACCESS DOOR
(TYPICAL).
1/
4" D
H W
HEAT TRAP IF
REQUIRED. 27"
DROP MINIMUM.
CAP
CAP
REMOVE EXISTING DOMESTIC
HOT WATER PIPING BACK TO
THIS LOCATION AND REPLACE
WITH NEW 2" DOMESTIC HOT
WATER PIPING.
EXISTING DOMESTIC HOT
WATER/DOMESTIC COLD WATER
PIPING TO REMAIN. COORDINATE
WITH OWNER TO MINIMIZE OUTAGE
TO OCCUPIED SPACES.
REMOVE EXISTING MIXING
VALVES AND ASSOCIATED
DOMESTIC PIPING. REFER TO
NEW WORK PLAN FOR NEW
WORK.
2" DCW
1 1/2" DHW
(E)2" DCW2" DHW
(E)2" DCW
1 1/2"
1 1/2" 1 1/2"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
M510
HCR-2N HCR-2N
NOTE:
IT IS NOT INTENDED THAT THE PLANS SHOW ALL OFFSETS IN PIPES, CONDUITS, AND DUCTS REQUIRED FOR INSTALLATION OF THE WORK. DETAILS AND SECTIONS ARE INCLUDED FOR SOME AREAS TO SHOW INTENDED RELATIONSHIP OF THE WORK OF VARIOUS TRADES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUB-CONTRACTORS TO COORDINATE INSTALLATION OF THE
WORK AND TO PROVIDE THE NECESSARY OFFSETS, TRANSFORMATIONS, AND FITTINGS REQUIRED. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CORRECTION CONFLICTS BETWEEN THE WORK OF VARIOUS TRADES. DETAILS AND SECTIONS ARE SHOWN FOR THE CONTRACTORS CONVENIENCE AND SHALL NOT BE CONSIDERED COMPLETE IN EVERY DETAIL.
C E N ENFO
SE
ENOIS AL
GN
I
E
AT
P R
S
T K
E
C.
CHRISTOPHER
KEATH
L I S
D RE
Y
EFO K
C
TN
U
18328
ARCHITECTSK E R S E Y A N D K E R S E Y
RTA DATE
DECA LOG #
A&E FILE NO.
CHECKED BY
DRAWN BY
DRAWING DATE
DRAWING INFORMATION
DRAWING NO.
AS BUILT DATE
PHASE
DATEDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWING
DATEDESCRIPTION OF REVISIONS
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
ACCOUNT NO.
Fax 502 585 2728 kerseyandkersey.com
Louisville, KY 40204
Tel 502 583 0094
839 East Gray Street Suite 207
Lexington, KY 40507
201 West Short Street Commiskey, IN 47227
Tel 812 873 1287
9307 West 1000 North
Tel 859 303 8439
LOUISVILLE, KENTUCKY LEXINGTON, KENTUCKY MADISON, INDIANA
2343 Alexandria Drive Suite 200 Lexington, KY 40504 Tel: 859-271-3246 Email: kfi@kfi-eng.com
/7
/2
:3
:4
P M
M510
DOMESTIC RISER DIAGRAM
15600 TURNER ROAD CRITTENDEN, KENTUCKY 41030
DJJ-NKYDC SHOWER RENOVATION
01/31/24
RTA
02/02/24
MM/DD/YR
DPT-FUND-ACTV--XX
Author
Checker
M510
HCR-1D HCR-1D
M510
HCR-1N HCR-1N
CODED NOTES:
1 1-1/4" DOMESTIC HOT WATER, 1-1/4" DOMESTIC COLD WATER, AND 2" TEMPERED WATER
PIPING TO/FROM NEW THERMOSTATIC MIXING VALVE SERVING NEW SHOWERS. INSTALL PER
MANUFACTURER'S RECOMMENDATION. MAINTAIN ACCESS THROUGH EXISTING ACCESS
PANEL.
2 REMOVE EXISTING TEMPERED HOT WATER BACK TO EXISTING MIXING VALVE APPROX. 50 FT.
FROM BATHROOM WALL, APPROX. 100 FT. PIPE TOTAL. COORDINATE WITH OWNER TO
MINIMIZE OUTAGE FOR ABOVE-CEILING WORK. REMOVE EXISTING MIXING VALVE AND CAP
DOMESTIC HOT WATER AND DOMESTIC COLD WATER PIPING ABOVE CEILING AS REQUIRED.
SEE NEW WORK PLUMBING PLANS FOR NEW MIXING VALVE AND TEMPERED HOT WATER
SERVING NEW SHOWERS.
3 REMOVE EXISTING 1-1/4" DOMESTIC HOT WATER PIPING BACK TO EXISTING 2" IN HALLWAY, APPROXIMATELY 50 FT. FROM BATHROOM, AND REPLACE WITH NEW 2" DOMESTIC HOT WATER
PIPING. SEE NEW WORK PLUMBING PLANS FOR NEW WORK.
4 EXTEND NEW 2" DOMESTIC HOT WATER PIPING ABOVE CEILING TO CONNECT INTO EXISTING 2"
PIPING APPROXIMATELY 50 FT. AWAY.
5 REMOVE EXISTING 1-1/4" DOMESTIC HOT WATER PIPING ABOVE CEILING TO THIS LOCATION
AND RECONNECT NEW.
6 REMOVE EXISTING DOMESTIC COLD WATER PIPING BACK TO MAIN. CAP AT MAIN AS REQUIRED.
7 PIPING ABOVE CEILING.
8 PIPING IN CHASE.
9 REMOVE EXISTING DOMESTIC HOT AND COLD WATER PIPING IN CHASE. SEE NEW WORK
PLUMBING PLANS AND ASSOCIATED RISER DIAGRAMS FOR RECONNECTION OF NEW AND AND
EXISTING FIXTURES TO NEW DOMESTIC HOT AND COLD WATER PIPING.
10 EXISTING DOMESTIC COLD WATER PIPING TO REMAIN.
11 REMOVE EXISTING DOMESTIC TEMPERED HOT WATER PIPING.
12 FIELD VERIFY CONNECTIONS OF EXISTING FIXTURES TO EXISTING PIPING IN CHASE. ENSURE
THAT ALL REMAINING FIXTURES ARE RECONNECTED TO NEW DOMESTIC HOT AND/OR COLD
WATER PIPING AS REQUIRED.
13 REMOVE EXISTING FIXTURE AND REMOVE ASSOCIATED DOMESTIC HOT AND COLD WATER
PIPING.
14 EXISTING WATER FOUNTAIN TO REMAIN. RECONNECT NEW DOMESTIC COLD WATER PIPING TO
EXISTING FIXTURE AS REQUIRED.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
GENERAL SHEET NOTE:
COORDINATE WITH OWNER TO MINIMIZE OUTAGES DURING SHOWER USE TIMES. ONE BATHROOM TO BE OPERATIONAL AT ALL TIMES WHEN POSSIBLE. COORDINATE WITH OWNER AND MAKE FINAL PLUMBING
CONNECTIONS DURING UNOCCUPIED PERIODS.
CONTRACTOR TO FIELD VERIFY EXISTING SANITARY WASTE, VENT, DOMESTIC HOT AND/OR DOMESTIC COLD WATER PIPING CONNECTIONS TO PLUMBING FIXTURES. MAINTAIN CONNECTIONS TO ALL EXISTING
PLUMBING FIXTURES TO REMAIN.
EXISTING DOMESTIC COLD
WATER PIPING AND VALVE
TO REMAIN. RECONNECT
NEW WATER CLOSET TO
PIPING.
1/4" = 1'-0"M510
1 MIXING VALVE SCHEMATIC PIPING DETAIL
M510
HCR-3D HCR-3D
| Addendum One |
| ADDENDUM #1 |
| Addendum # 1.pdf |
| COMMONWEALTH OF KENTUCKY |
| DJJ-Northern Kentucky Youth Development Center |
| 15600 Turner Road Crittenden, KY |
| M210 - UNDERFLOOR PLUMBING PLAN |
| Sheets |
| M210 - UNDERFLOOR PLUMBING PLAN |
| M211 - LEVEL 1 PLUMBING PLAN |
| M510 - DOMESTIC RISER DIAGRAM |
| M211 - LEVEL 1 PLUMBING PLAN |
| Sheets |
| M210 - UNDERFLOOR PLUMBING PLAN |
| M211 - LEVEL 1 PLUMBING PLAN |
| M510 - DOMESTIC RISER DIAGRAM |
| M510 - DOMESTIC RISER DIAGRAM |
| Sheets |
| M510 - DOMESTIC RISER DIAGRAM |
File details come from the government source that posted it. Updated .