This is Addendum No. 1 to Invitation to Bid (RFB-160-25) issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration, in conjunction with the Transportation Cabinet for roof and exterior repairs at the East and West Bound Carter County Rest Areas located at I-64, Mile Marker 173.5, in Carter County, Kentucky. The project involves comprehensive roofing and exterior work including removal and replacement of roofing systems, installation of new standing seam metal roof systems, new fascia and soffit components, snow and ice guards, gutters, downspouts, and metal wall panels at both rest area facilities. A site visit for bidders was held on December 17, 2024, at 9:00 a.m. The addendum, dated January 2, 2025, clarifies and modifies the original bid documents and includes five substantive items addressing revisions to construction drawings and specifications.
Addendum Item 1 modifies Sheet A1 (Roof Demo Plan for Restroom West) to delete reference to removal of the roof deck, requiring existing roof sheathing to remain. Item 2 completely reissues Sheet A2 (Roof New Work Plan for Restroom West) with several corrections noted in revision clouds. Item 3 modifies Sheet A3 (Roof Demo & New Work Plan for Restroom East) to delete reference to removal of the plywood deck at lower roof areas. Item 4 completely reissues Sheet A7 (Demo & New Work for Vending East and West) with several corrections. Item 5 adds Section 077100 "Roof Specialties" to the contract documents, which had been omitted from the original bid package. The specifications detail requirements for aluminum roof-edge drainage systems including gutters (6" Style K profile), downspouts (3"x4" profile), drip edges, fascia, soffit components, base flashing, and counterflashing, with all materials fabricated from 0.019-inch-thick aluminum. The addendum includes three attachments: reissued Sheets A2 and A7 and the complete Roof Specialties specification section.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_RFB_785_2500000334_2_SO_FORM.PDF | ||
| Final_RFB_785_2500000334_1_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-160-25
FOR: Roof and Exterior Repairs East and West Bound Carter County Rest Areas Transportation Cabinet Carter County, Kentucky
DATE: January 3, 2025
RFB-785-2500000334
ADDENDUM NO. One (1)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-160-25 For: Roof and Exterior Repairs East and West Bound Carter County Rest Areas Transportation Cabinet Carter County, Kentucky
Kristi Sharp, Statewide Procurement Manager Division of Engineering and Contract Administration
ADDENDUM 01 1
ADDENDUM 01 January 2, 2025
KYTC - Carter County Rest Areas Re-Roof and Exterior Repairs Gallagher Office of Architecture, LLC I-64 East and West, Mile Marker 173.5, Carter County, Kentucky 227 Miller Street Account No. 625-CBEG-Z001-49 Lexington, Kentucky 40507
Site Visit for Bidders Held December 17, 2024 at 9:00 am Attendees:
Addendum 01
Item 1: Refer to Drawings, Sheet A1, “Roof Demo Plan (Restroom West)”, delete reference to removal of “ROOF DECK” on the Roof Demo Plan. The existing roof sheathing is to remain.
Item 2: Refer to Drawings, Sheet A2, “Roof New Work Plan (Restroom West)”, several corrections are noted revision clouds. Sheet A2 is reissued entirely.
Item 3: Refer to Drawings, Sheet A3, “Roof Demo & New Work Plan (Restroom East)”, delete reference to removal of “1/2” PLYWOOD DECK”. The existing roof sheathing is to remain at the lower roof areas.
Item 4: Refer to Drawings, Sheet A7, “Demo & New Work (Vending East and West)”, several corrections are noted revision clouds. Sheet A7 is reissued entirely.
Item 5: Refer to Specifications, Section 077100 “Roof Specialties” was omitted from the documents. This sections is attached to the this addendum to be incorporated into the Contract Documents.
Attachments 01 Drawing 24”x36”, Sheet A2 “Roof New Work Plan (Restroom West)” 02 Drawing 24”x36”, Sheet A7 “Demo & New Work (Vending East and West)” 03 Specifications, Section 077100 “Roof Specialties”
End of Addendum 01
ROOF NEW WORK PLAN (RESTROOM WEST)
ROOF NEW WORK PLAN (RESTROOM WEST)
A2
KYTC - CARTER COUNTY REST AREAS RE-ROOF AND EXTERIOR REPAIRS
I-64 East and West, Mile Marker 173.5, Carter County, Kentucky
GALLAGHER
OFFICE OF ARCHITECTURE
227 Miller Street, Lexington, KY 40507 859-619-2079 www.gallagheroa.com
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text NEW CONCEALED FASTENER METAL ROOF SYSTEM OVER SELF-ADHERING UNDERLAYMENT OVER NEW TONGUE & GROOVE SHEATHING EXISTING PLYWOOD DECK (TYP.)
AutoCAD SHX Text
NEW SNOW AND ICE GUARDS (TYP.)
AutoCAD SHX Text L/H
AutoCAD SHX Text A7
AutoCAD SHX Text K
AutoCAD SHX Text A7
AutoCAD SHX Text L
AutoCAD SHX Text A7
AutoCAD SHX Text K
AutoCAD SHX Text A7
AutoCAD SHX Text K
AutoCAD SHX Text A7
AutoCAD SHX Text L
AutoCAD SHX Text A7
AutoCAD SHX Text K
AutoCAD SHX Text A7
AutoCAD SHX Text K
AutoCAD SHX Text A7
AutoCAD SHX Text F
AutoCAD SHX Text A7
AutoCAD SHX Text F
AutoCAD SHX Text A7
AutoCAD SHX Text F
AutoCAD SHX Text A7
AutoCAD SHX Text F
AutoCAD SHX Text A7
AutoCAD SHX Text L/H
AutoCAD SHX Text A7
AutoCAD SHX Text
ADDENDUM 01 1/2/2025
AutoCAD SHX Text
ADDENDUM 01 1/2/2025
AutoCAD SHX Text F
AutoCAD SHX Text A7
AutoCAD SHX Text F
AutoCAD SHX Text A7
AutoCAD SHX Text
ADDENDUM 01 1/2/2025
AutoCAD SHX Text
ADDENDUM 01 1/2/2025
AutoCAD SHX Text 10/8/2024
AutoCAD SHX Text
RTA DATE
AutoCAD SHX Text
DECA LOG #
AutoCAD SHX Text
A&E FILE NO.
AutoCAD SHX Text
BCG
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
BCG
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text 10/8/2024
AutoCAD SHX Text
DRAWING DATE
AutoCAD SHX Text
DRAWING INFORMATION
AutoCAD SHX Text 2024.02
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
AS BUILT DATE
AutoCAD SHX Text
AutoCAD SHX Text
PHASE
AutoCAD SHX Text C
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION HISTORY OF THIS DRAWING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
FRANKFORT, KENTUCKY
AutoCAD SHX Text
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
AutoCAD SHX Text
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
AutoCAD SHX Text
FINANCE AND ADMINISTRATION CABINET
AutoCAD SHX Text
COMMONWEALTH OF KENTUCKY
AutoCAD SHX Text
ACCOUNT NO.
AutoCAD SHX Text
625-CBEG-Z001-49
AutoCAD SHX Text
6" DIA. GALV. STEEL COLUMN, FILL WITH CONCRETE, ROUND AT TOP - PAINT - TYP.
AutoCAD SHX Text
12" EXPANSION JOINT MATERIAL
AutoCAD SHX Text
CONCRETE BOLLARD FOUNDATION
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text 24"
AutoCAD SHX Text 42"
AutoCAD SHX Text
BOLLARD
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A
AutoCAD SHX Text A2
AutoCAD SHX Text
ADDENDUM 01
AutoCAD SHX Text 1/2/2025
ROOF PLAN (EXISTING) ROOF PLAN (NEW)
VENDING BUILDING SECTION (NEW WORK) VENDING BUILDING SECTION (NEW WORK)
VENDING BUILDING SECTION (DEMO)VENDING BUILDING SECTION (DEMO)
SITE PLAN (WEST)
VENDING EAVE (EAST & WEST)
RESTROOM EAVE (EAST)
TYPICAL RAKE VENTED RIDGE
ROOF TO WALLRESTROOM EAVE (WEST)
RIDGE / HIP
SHED PEAK (RESTROOM WEST)
EQ.
CL
EQ.
TYPICAL PIPE FLASHING
DEMO & NEW WORK (VENDING EAST AND WEST)
A7
KYTC - CARTER COUNTY REST AREAS RE-ROOF AND EXTERIOR REPAIRS
I-64 East and West, Mile Marker 173.5, Carter County, Kentucky
GALLAGHER
OFFICE OF ARCHITECTURE
227 Miller Street, Lexington, KY 40507 859-619-2079 www.gallagheroa.com
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text E
AutoCAD SHX Text A7
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text D
AutoCAD SHX Text A7
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text C
AutoCAD SHX Text A7
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text A
AutoCAD SHX Text A7
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text B
AutoCAD SHX Text A7
AutoCAD SHX Text
NEW SNOW AND ICE GUARDS (TYP.)
AutoCAD SHX Text
NEW SNOW AND ICE GUARDS (TYP.)
AutoCAD SHX Text
NEW SNOW AND ICE GUARDS (TYP.)
AutoCAD SHX Text
NEW SNOW AND ICE GUARDS (TYP.)
AutoCAD SHX Text REMOVE ASPHALT SHINGLES, BUIILT-UP ROOF, AND ROOF FRAMING PER DEMOLITION SECTIONS A/A3 AND B/A3.
AutoCAD SHX Text REMOVE CANTED 2x FRAMING, ASPHALT SHINGLES AND COPING ALL SIDES OF BUILDING (TYP.)
AutoCAD SHX Text
REMOVE ASPHALT SHINGLE ROOFING SYSTEM DOWN TO EXISTING PLYWOOD DECK (TYP.)
AutoCAD SHX Text
REMOVE EXISTING FASCIA AND SOFFIT (TYP.)
AutoCAD SHX Text
REMOVE EXISTING WD. CEILING (TYP.)
AutoCAD SHX Text
VENDING MACHINES
AutoCAD SHX Text
VENDING MACHINES
AutoCAD SHX Text
VENDING MACHINES
AutoCAD SHX Text
VENDING MACHINES
AutoCAD SHX Text
NO WORK IN VENDING STORAGE AREA
AutoCAD SHX Text REMOVE CANTED 2x FRAMING, ASPHALT SHINGLES AND COPING ALL SIDES OF BUILDING (TYP.)
AutoCAD SHX Text
REMOVE ASPHALT SHINGLE ROOFING SYSTEM DOWN TO EXISTING PLYWOOD DECK (TYP.)
AutoCAD SHX Text
REMOVE EXISTING FASCIA (TYP.)
AutoCAD SHX Text
REMOVE EXISTING WD. CEILING (TYP.)
AutoCAD SHX Text
NEW RIDGE VENT BY METAL ROOF MANUFACTURER
AutoCAD SHX Text NEW 2x8 RAFTERS AT 24" O.C.
AutoCAD SHX Text
NEW METAL FASCIA AT EAVE (TYP.)
AutoCAD SHX Text
NEW VENTED METAL SOFFIT (TYP.)
AutoCAD SHX Text
NEW STANDING SEAM METAL ROOF SYSTEM (TYP.)
AutoCAD SHX Text
NEW SNOW AND ICE GUARDS (TYP.)
AutoCAD SHX Text
NEW LINEAR METAL CEILING
AutoCAD SHX Text
EXISTING BRICK MASONRY, CLEAN PER SPECS. (TYP.)
AutoCAD SHX Text
NO WORK IN VENDING STORAGE AREA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXIST. RAFTERS TO REMAIN
AutoCAD SHX Text
EXIST. RAFTERS TO REMAIN
AutoCAD SHX Text
EXIST. RAFTERS TO REMAIN
AutoCAD SHX Text
EXIST. RAFTERS TO REMAIN
AutoCAD SHX Text
EXIST. RAFTERS TO REMAIN
AutoCAD SHX Text
EXIST. RAFTERS TO REMAIN
AutoCAD SHX Text
EXIST. RAFTERS TO REMAIN
AutoCAD SHX Text
EXIST. RAFTERS TO REMAIN
AutoCAD SHX Text NEW 2x8 CONTINUOUS RIDGE BEAM
AutoCAD SHX Text M
AutoCAD SHX Text A7
AutoCAD SHX Text CUT 2x FRAMING FLUSH TOP OF RAFTERS
AutoCAD SHX Text CUT 2x FRAMING FLUSH TOP OF RAFTERS
AutoCAD SHX Text CUT 2x FRAMING FLUSH TOP OF RAFTERS
AutoCAD SHX Text M
AutoCAD SHX Text A7
AutoCAD SHX Text M
AutoCAD SHX Text A7
AutoCAD SHX Text M
AutoCAD SHX Text A7
AutoCAD SHX Text G
AutoCAD SHX Text A7
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
ADDEMDUM 01 1/2/2025
AutoCAD SHX Text
ADDEMDUM 01 1/2/2025
AutoCAD SHX Text
ADDEMDUM 01 1/2/2025
AutoCAD SHX Text
CONNECT NEW DOWNSPOUTS TO EXISTING BOOT LOCATIONS (TYP.)
AutoCAD SHX Text
CONNECT NEW DOWNSPOUTS TO EXISTING BOOT LOCATIONS (TYP.)
AutoCAD SHX Text
ADDEMDUM 01 1/2/2025
AutoCAD SHX Text
ADDEMDUM 01 1/2/2025
AutoCAD SHX Text PANEL CLIP 48" O.C. MAX (FASTENED WITH PANCAKE HEAD FASTNER PER MANUF., MIN. 1/2" PENETRATION TO DECK).
AutoCAD SHX Text
APPROVED UNDERLAYMENT
AutoCAD SHX Text
SELF-ADHERED ICE AND WATER UNDERLAYMENT (EXTEND DOWN FASCIA 4")
AutoCAD SHX Text
POP RIVET 12" O.C. (DO NOT PENETRATE PANEL LEG)
AutoCAD SHX Text
CONTINUOUS ROW OF BUTYL TAPE
AutoCAD SHX Text
NEW J CLOSURE
AutoCAD SHX Text
NEW RAKE EDGE WITH CONCEALED CLEAT
AutoCAD SHX Text
NEW PLYWOOD SHEATHING AS NECESSARY
AutoCAD SHX Text
NEW ROOF SHEATHING (TYP.)
AutoCAD SHX Text
NEW STANDING SEAM METAL ROOF SYSTEM (TYP.)
AutoCAD SHX Text
NEW METAL DRIP EDGE (TYP.)
AutoCAD SHX Text
EXIST. ROOF SHEATHING (TYP.)
AutoCAD SHX Text
NEW METAL RIDGE
AutoCAD SHX Text
INJECT APPROVED SEALANT BETWEEN PANEL LEG AND ZEE CLOSURE
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
CLIPS AND FASTENERS PER ROOF MANUF.
AutoCAD SHX Text
NEW STANDING SEAM METAL ROOFING SYSTEM (TYP.)
AutoCAD SHX Text
12" MAX.
AutoCAD SHX Text
BOX END OF PANEL AND INJECT APPROVED SEALANT IN CORNERS (TYP.)
AutoCAD SHX Text 2"
AutoCAD SHX Text
POP RIVET 12" O.C. PER ROOFING MANUF.
AutoCAD SHX Text
NEW PREFINISHED METAL WALL PANELS (TYP. AT GABLES, WEST BOUND RESTROOM ONLY)
AutoCAD SHX Text
NEW Z CLOSURE
AutoCAD SHX Text
NEW PREFINISHED METAL WALL PANELS (TYP. AT VERTICAL WALLS EAST RESTROOM ONLY)
AutoCAD SHX Text
CONTINUOUS ROW OF BUTYL TAPE
AutoCAD SHX Text
EXIST. ROOF SHEATHING (TYP.)
AutoCAD SHX Text
NEW PREFINISHED STANDING SEAM METAL ROOF SYSTEM (TYP.)
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text M
AutoCAD SHX Text A7
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text J
AutoCAD SHX Text A7
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text F
AutoCAD SHX Text A7
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text E
AutoCAD SHX Text A7
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text H
AutoCAD SHX Text A7
AutoCAD SHX Text NEW TWO-PIECE METAL FASCIA, WRAP INTO EXIST. GUTTER, SEAL W/BUTYL, SIZE METAL PROFILE TO ALLOW FASCIA TO FLOAT FREELY AND CONCEAL IRREGULARITIES IN THE EXISTING SUB-FRAMING (TYP.)
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text K
AutoCAD SHX Text A7
AutoCAD SHX Text
NEW STANDING SEAM METAL ROOF SYSTEM (TYP.)
AutoCAD SHX Text
NEW METAL DRIP EDGE (TYP.)
AutoCAD SHX Text
EXIST. ROOF SHEATHING (TYP.)
AutoCAD SHX Text
NEW METAL FASCIA (TYP.)
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text G
AutoCAD SHX Text A7
AutoCAD SHX Text
NEW METAL RIDGE
AutoCAD SHX Text
INJECT APPROVED SEALANT BETWEEN PANEL LEG AND ZEE CLOSURE
AutoCAD SHX Text
ZEE CLOSURE
AutoCAD SHX Text
NEW STANDING SEAM METAL ROOFING SYSTEM (TYP.)
AutoCAD SHX Text
CLIPS AND FASTENERS PER ROOF MANUF.
AutoCAD SHX Text
POP RIVET AS REQUIRED TO FLUSH THE LAP OF THE RIDGE/HIP FLASHING
AutoCAD SHX Text
3/4" TURN-UP
AutoCAD SHX Text
SELF-ADHERED ICE AND WATER UNDERLAYMENT
AutoCAD SHX Text
NEW METAL GUTTER (TYP.)
AutoCAD SHX Text
NEW SNOW AND ICE GUARDS (TYP.)
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text L
AutoCAD SHX Text A7
AutoCAD SHX Text 1-1/2" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text A7
AutoCAD SHX Text
NEW PREFINISHED METAL WALL PANELS (TYP. AT VERTICAL WALLS)
AutoCAD SHX Text
NEW PEAK FLASHING WITH CONCEALED CLEAT
AutoCAD SHX Text
NEW CONCEALED CLIP (TYP.)
AutoCAD SHX Text
NEW STANDING SEAM METAL ROOF SYSTEM (TYP.)
AutoCAD SHX Text
EXIST. ROOF SHEATHING (TYP.)
AutoCAD SHX Text
NEW STANDING SEAM METAL ROOF SYSTEM (TYP.)
AutoCAD SHX Text
NEW METAL DRIP EDGE (TYP.)
AutoCAD SHX Text
EXIST. ROOF SHEATHING (TYP.)
AutoCAD SHX Text
NEW METAL FASCIA (TYP.)
AutoCAD SHX Text
NEW METAL GUTTER (TYP.)
AutoCAD SHX Text
NEW SNOW AND ICE GUARDS (TYP.)
AutoCAD SHX Text
EXIST. FIBER CEMENT SIDING TO REMAIN (TYP. AT VERTICAL WALLS)
AutoCAD SHX Text
NEW METAL SOFFIT (TYP.)
AutoCAD SHX Text
EXIST. METAL SOFFIT (TYP.)
AutoCAD SHX Text
NEW METAL SOFFIT (TYP.)
AutoCAD SHX Text EXTEND EA. RAFTER TAIL TO CREATE VERTICAL PLANE FOR NEW 2x SUB-FASCIA (TYP.)
AutoCAD SHX Text
ADDENDUM 01 1/2/2025
AutoCAD SHX Text 10/8/2024
AutoCAD SHX Text
RTA DATE
AutoCAD SHX Text
DECA LOG #
AutoCAD SHX Text
A&E FILE NO.
AutoCAD SHX Text
BCG
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
BCG
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text 10/8/2024
AutoCAD SHX Text
DRAWING DATE
AutoCAD SHX Text
DRAWING INFORMATION
AutoCAD SHX Text 2024.02
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
AS BUILT DATE
AutoCAD SHX Text
AutoCAD SHX Text
PHASE
AutoCAD SHX Text C
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISION HISTORY OF THIS DRAWING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION OF REVISIONS
AutoCAD SHX Text
FRANKFORT, KENTUCKY
AutoCAD SHX Text
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
AutoCAD SHX Text
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
AutoCAD SHX Text
FINANCE AND ADMINISTRATION CABINET
AutoCAD SHX Text
COMMONWEALTH OF KENTUCKY
AutoCAD SHX Text
ACCOUNT NO.
AutoCAD SHX Text
625-CBEG-Z001-49
AutoCAD SHX Text
(2) NEW BOLLARDS PER DETAIL A/A2, FIELD VERIFY EXACT LOCATION WITH ARCHITECT ON SITE
AutoCAD SHX Text
ADDENDUM 01
AutoCAD SHX Text 1/2/2025
KYTC - Carter County Rest Areas Re-Roof and Exterior Repairs 625-CBEG-Z001-49
ROOF SPECIALTIES 077100 - 1
SECTION 077100 - ROOF SPECIALTIES
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Roof-edge drainage systems.
2. Base Flashing and Counterflashing.
1.2 SUBMITTALS
A. Product Data: For each type of product indicated.
B. Samples: For each exposed product and for each color and texture specified.
C. Warranty: Sample special warranty.
1.3 WARRANTY
A. Special Warranty on Painted Finishes: Manufacturer’s standard form in which manufacturer agrees to repair finish or replace roof specialties that show evidence of deterioration of factory-applied finishes within 10 years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 EXPOSED METALS
A. Aluminum Sheet: ASTM B 209 (ASTM B 209M), alloy as standard with manufacturer for finish required, with temper to suit forming operations and performance required.
1. Surface: Smooth, flat finish.
2. Exposed Coil-Coated Finishes: Prepare, pretreat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions.
a. Two-Coat Fluoropolymer: AAMA 620. System consisting of primer and fluoropolymer color topcoat containing not less than 70 percent PVDF resin by weight.
2.2 CONCEALED METALS
A. Aluminum Sheet: ASTM B 209 (ASTM B 209M), alloy and temper recommended by manufacturer for type of use and structural performance indicated, factory primed.
ROOF SPECIALTIES 077100 - 2
2.3 MISCELLANEOUS MATERIALS
A. General: Provide materials and types of fasteners, protective coatings, sealants, and other miscellaneous items required by manufacturer for a complete installation.
B. Elastomeric Sealant: ASTM C 920, elastomeric polymer sealant of type, grade, class, and use classifications required by roofing-specialty manufacturer for each application.
C. Bituminous Coating: Cold-applied asphalt emulsion complying with ASTM D 1187.
2.4 ROOF-EDGE DRAINAGE SYSTEMS
A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
1. Petersen Aluminum, a Carlisle Company
2. Metal Sales Corporation
3. Drexel Metals, a Carlisle Company
4. Dimensional Metals, Inc
B. Gutters: Manufactured in continuous, uniform section lengths without seams, with matching corner units, ends, outlet tubes, and other accessories. Elevate back edge at least 1 inch (25
mm) above front edge. Furnish flat-stock gutter straps, gutter brackets, from same metal as gutters.
1. Fabricate from the following exposed metal:
a. Formed Aluminum: 0.019 inch thick.
2. Gutter Profile: 6” Style K according to SMACNA's "Architectural Sheet Metal Manual."
3. Gutter Accessories: Continuous hinged leaf guard of solid metal designed to shed leaves.
C. Downspouts: Corrugated rectangular complete with machine-crimped elbows, manufactured from the following exposed metal. Furnish with metal hangers, from same material as downspouts, and anchors.
1. Formed Aluminum: 0.019 inch thick.
2. Downspout Profile: 3”x4”
3. Provide black ABS downspout boot to transition to below grade drainage piping.
D. Drip Edges: Fabricate from the following materials:
1. Aluminum: 0.019 inch thick.
E. Eave, Rake Fascia: Fabricate from the following materials:
ROOF SPECIALTIES 077100 - 3
1. Aluminum: 0.019 inch thick.
F. Vented Soffit: Fabricate from the following materials:
1. Aluminum: 0.019 inch thick.
2.5 BASE FLASHING AND COUNTERFLASHING
A. Base Flashing: Fabricate from the following materials:
1. Aluminum: 0.019 inch thick.
B. Counterflashing: Fabricate from the following materials:
1. Aluminum: 0.019 inch thick.
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. General: Install roof specialties according to manufacturer's written instructions. Anchor roof specialties securely in place, with provisions for thermal and structural movement. Use fasteners, solder, protective coatings, separators, sealants, and other miscellaneous items as required to complete roof-specialty systems.
1. Install roof specialties level, plumb, true to line and elevation; with limited oil-canning and without warping, jogs in alignment, buckling, or tool marks.
2. Provide uniform, neat seams with minimum exposure of solder and sealant.
3. Install roof specialties to fit substrates and to result in watertight performance. Verify shapes and dimensions of surfaces to be covered before manufacture.
4. Torch cutting of roof specialties is not permitted.
5. Install underlayment with adhesive for temporary anchorage. Apply in shingle fashion to shed water, with lapped joints of not less than 2 inches (50 mm).
6. Provide a reveal break in rake fascia to prevent “oil canning” or expansion/contraction deformities in the fascia metal.
7. Install metal soffits over metal hat-channel furring with shims at each existing sub-framing member to create a flat and level plane for soffit.
B. Metal Protection: Protect metals against galvanic action by separating dissimilar metals from contact with each other or with corrosive substrates by painting contact surfaces with bituminous coating or by other permanent separation as recommended by manufacturer.
1. Coat concealed side of uncoated aluminum roof specialties with bituminous coating where in contact with wood, ferrous metal, or cementitious construction.
2. Underlayment: Where installing metal flashing directly on cementitious or wood substrates, install a course of self-adhering, high-temperature sheet underlayment.
C. Fastener Sizes: Use fasteners of sizes that will penetrate substrate not less than recommended by fastener manufacturer to achieve maximum pull-out resistance.
ROOF SPECIALTIES 077100 - 4
D. Seal joints as required for watertight construction. Place sealant to be completely concealed in joint. Do not install sealants at temperatures below 40 deg F (4 deg C).
3.2 ROOF-EDGE DRAINAGE-SYSTEM INSTALLATION
A. General: Install components to produce a complete roof-edge drainage system according to manufacturer's written instructions.
B. Gutters: Join and seal gutter lengths. Allow for thermal expansion. Attach gutters to firmly anchored gutter supports spaced not more than 24 inches (610 mm) apart. Attach ends with rivets and seal with sealant to make watertight. Slope to downspouts.
1. Install continuous leaf guards on gutters with noncorrosive fasteners, hinged to swing open for cleaning gutters.
C. Downspouts: Join sections with manufacturer's standard telescoping joints. Provide hangers with fasteners designed to hold downspouts securely to walls and 1 inch (25 mm) away from walls; locate fasteners at top and bottom and at approximately 60 inches (1500 mm) o.c.
D. Opening Flashings in Frame Construction: Install continuous head, sill, jamb, and similar flashings to extend 4 inches beyond wall openings.
3.3 CLEANING AND PROTECTION
A. Clean exposed metal surfaces of substances that interfere with uniform oxidation and weathering.
B. Remove temporary protective coverings and strippable films as roof specialties are installed.
END OF SECTION 077100
| Addendum No One.pdf |
| Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings. |
| END OF ADDENDUM |
| CBEG Addendum 01.pdf |
| 00 2025-01-02 Addendum 1 |
| 01 Drawing Sheet A2 |
| Sheets and Views |
| 02 New Work West |
| 02 Drawing Sheet A7 |
| Sheets and Views |
| 07 Vending |
| 03 Section 077100 - Roof Specialties |
| PART 1 - GENERAL |
| 1.1 SUMMARY |
| A. Section Includes: |
| 1. Roof-edge drainage systems. |
| 2. Base Flashing and Counterflashing. |
| 1.2 SUBMITTALS |
| A. Product Data: For each type of product indicated. |
| B. Samples: For each exposed product and for each color and texture specified. |
| C. Warranty: Sample special warranty. |
| 1.3 WARRANTY |
| A. Special Warranty on Painted Finishes: Manufacturer’s standard form in which manufacturer agrees to repair finish or replace roof specialties that show evidence of deterioration of factory-applied finishes within 10 years from date of Substantial Co... |
| PART 2 - PRODUCTS |
| 2.1 EXPOSED METALS |
| A. Aluminum Sheet: ASTM B 209 (ASTM B 209M), alloy as standard with manufacturer for finish required, with temper to suit forming operations and performance required. |
| 1. Surface: Smooth, flat finish. |
| 2. Exposed Coil-Coated Finishes: Prepare, pretreat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions. |
| a. Two-Coat Fluoropolymer: AAMA 620. System consisting of primer and fluoropolymer color topcoat containing not less than 70 percent PVDF resin by weight. |
| 2.2 CONCEALED METALS |
| A. Aluminum Sheet: ASTM B 209 (ASTM B 209M), alloy and temper recommended by manufacturer for type of use and structural performance indicated, factory primed. |
| 2.3 MISCELLANEOUS MATERIALS |
| A. General: Provide materials and types of fasteners, protective coatings, sealants, and other miscellaneous items required by manufacturer for a complete installation. |
| B. Elastomeric Sealant: ASTM C 920, elastomeric polymer sealant of type, grade, class, and use classifications required by roofing-specialty manufacturer for each application. |
| C. Bituminous Coating: Cold-applied asphalt emulsion complying with ASTM D 1187. |
| 2.4 ROOF-EDGE DRAINAGE SYSTEMS |
| A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: |
| 1. Petersen Aluminum, a Carlisle Company |
| 2. Metal Sales Corporation |
| 3. Drexel Metals, a Carlisle Company |
| 4. Dimensional Metals, Inc |
| B. Gutters: Manufactured in continuous, uniform section lengths without seams, with matching corner units, ends, outlet tubes, and other accessories. Elevate back edge at least 1 inch (25 mm) above front edge. Furnish flat-stock gutter straps, gutte... |
| 1. Fabricate from the following exposed metal: |
| a. Formed Aluminum: 0.019 inch thick. |
| 2. Gutter Profile: 6” Style K according to SMACNA's "Architectural Sheet Metal Manual." |
| 3. Gutter Accessories: Continuous hinged leaf guard of solid metal designed to shed leaves. |
| C. Downspouts: Corrugated rectangular complete with machine-crimped elbows, manufactured from the following exposed metal. Furnish with metal hangers, from same material as downspouts, and anchors. |
| 1. Formed Aluminum: 0.019 inch thick. |
| 2. Downspout Profile: 3”x4” |
| 3. Provide black ABS downspout boot to transition to below grade drainage piping. |
| D. Drip Edges: Fabricate from the following materials: |
| 1. Aluminum: 0.019 inch thick. |
| E. Eave, Rake Fascia: Fabricate from the following materials: |
| 1. Aluminum: 0.019 inch thick. |
| F. Vented Soffit: Fabricate from the following materials: |
| 1. Aluminum: 0.019 inch thick. |
| 2.5 BASE FLASHING AND COUNTERFLASHING |
| A. Base Flashing: Fabricate from the following materials: |
| 1. Aluminum: 0.019 inch thick. |
| B. Counterflashing: Fabricate from the following materials: |
| 1. Aluminum: 0.019 inch thick. |
| PART 3 - EXECUTION |
| 3.1 INSTALLATION, GENERAL |
| A. General: Install roof specialties according to manufacturer's written instructions. Anchor roof specialties securely in place, with provisions for thermal and structural movement. Use fasteners, solder, protective coatings, separators, sealants, ... |
| 1. Install roof specialties level, plumb, true to line and elevation; with limited oil-canning and without warping, jogs in alignment, buckling, or tool marks. |
| 2. Provide uniform, neat seams with minimum exposure of solder and sealant. |
| 3. Install roof specialties to fit substrates and to result in watertight performance. Verify shapes and dimensions of surfaces to be covered before manufacture. |
| 4. Torch cutting of roof specialties is not permitted. |
| 5. Install underlayment with adhesive for temporary anchorage. Apply in shingle fashion to shed water, with lapped joints of not less than 2 inches (50 mm). |
| 6. Provide a reveal break in rake fascia to prevent “oil canning” or expansion/contraction deformities in the fascia metal. |
| 7. Install metal soffits over metal hat-channel furring with shims at each existing sub-framing member to create a flat and level plane for soffit. |
| B. Metal Protection: Protect metals against galvanic action by separating dissimilar metals from contact with each other or with corrosive substrates by painting contact surfaces with bituminous coating or by other permanent separation as recommended ... |
| 1. Coat concealed side of uncoated aluminum roof specialties with bituminous coating where in contact with wood, ferrous metal, or cementitious construction. |
| 2. Underlayment: Where installing metal flashing directly on cementitious or wood substrates, install a course of self-adhering, high-temperature sheet underlayment. |
| C. Fastener Sizes: Use fasteners of sizes that will penetrate substrate not less than recommended by fastener manufacturer to achieve maximum pull-out resistance. |
| D. Seal joints as required for watertight construction. Place sealant to be completely concealed in joint. Do not install sealants at temperatures below 40 deg F (4 deg C). |
| 3.2 ROOF-EDGE DRAINAGE-SYSTEM INSTALLATION |
| A. General: Install components to produce a complete roof-edge drainage system according to manufacturer's written instructions. |
| B. Gutters: Join and seal gutter lengths. Allow for thermal expansion. Attach gutters to firmly anchored gutter supports spaced not more than 24 inches (610 mm) apart. Attach ends with rivets and seal with sealant to make watertight. Slope to down... |
| 1. Install continuous leaf guards on gutters with noncorrosive fasteners, hinged to swing open for cleaning gutters. |
| C. Downspouts: Join sections with manufacturer's standard telescoping joints. Provide hangers with fasteners designed to hold downspouts securely to walls and 1 inch (25 mm) away from walls; locate fasteners at top and bottom and at approximately 60 ... |
| D. Opening Flashings in Frame Construction: Install continuous head, sill, jamb, and similar flashings to extend 4 inches beyond wall openings. |
| 3.3 CLEANING AND PROTECTION |
| A. Clean exposed metal surfaces of substances that interfere with uniform oxidation and weathering. |
| B. Remove temporary protective coverings and strippable films as roof specialties are installed. |