This is Addendum No. 1 issued by the Fairfax County Department of Public Works and Environmental Services, Wastewater Design and Construction Division for the Accotink Gravity Sewer Improvements pre-qualification request (Project No. WW-000032-007). The project involves approximately 15,000 feet of new 42-inch pipe to be constructed by either open cut construction or trenchless methods, plus approximately 8,000 feet of cured-in-place liner pipe. The pre-qualification application modifies requirements for contractor experience, requiring demonstration of completing at least three similar gravity sewer projects for governmental, institutional or private owners, each with an original contract value of $40 million or more within the past seven years. Pre-qualification applications are due February 27, 2025 at 1:00 PM, with submissions accepted via email or hand delivery.
A non-mandatory pre-qualification meeting was held on February 13, 2025 where additional details were clarified, including that subcontractors do not need to provide qualifications, no Project Labor Agreement will be required, and material testing/inspection requirements will be outlined in the final bid documents. The project will not have reduced qualification requirements to allow for more competition. MBE/DBE requirements, if any, will be specified in the future bid documents. Organization charts should only include the division responsible for project construction, and financial statements are only required upon request.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum No. 1
DEPARTMENT OF PUBLIC WORKS COUNTY OF FAIRFAX
AND ENVIRONMENTAL SERVICES VIRGINIA
WASTEWATER DESIGN AND CONSTRUCTION DIVISION
ADDENDUM NO. 1
ACCOTINK GRAVITY SEWER IMPROVEMENTS
CONTRACTOR PRE-QUALIFICATION REQUEST
PROJECT NO. WW-000032-007
This addendum consists of 6 pages including all attachments.
This addendum is supplementary to the pre-qualification advertisement documents posted for the Accotink Gravity Sewer Improvements Project.
All revisions, additions or deletions included herein as Addendum No. 1 shall become a part of the advertised documents.
Contents of Addendum No.1:
DOCUMENT DESCRIPTION
PRE-QUALIFICATION
APPLICATION
INSTRUCTIONS
1.1 Section 7, Introduction
DELETE in its entirety and REPLACE with “The pre-qualification application shall demonstrate the experience of the Applicant as a general contractor for gravity sewer projects. The Applicant shall describe their experience, specifically identifying and describing the following:”
1.2 Section 7.A.2 DELETE in its entirety and REPLACE with “2. The Applicant shall have acted as a General Contractor and have completed at least three (3) similar gravity sewer projects for governmental, institutional or private owners, each with an original contract value of $40,000,000 or more within the past seven (7) years.
Experience with trenchless pipe installation as well as experience in rehabilitation of existing pipe will be major factors in determining eligibility to bid.”
Questions:
Responses to questions are for Information Purposes only and are not part of the addendum.
Any modifications, or changes, to the advertised documents shall be as listed under the “Contents of Addendum No. 1” listed above.
Q1. Section 5C states that the projects have to be completed within the last 7 years but then
Section 6A states to list projects currently being performed OR completed with 10 years.
Can you please clarify how many years and if current projects will be allowed?
Addendum No. 1
A1. Section 5.C.2 indicates that the Contractor should provide information on three (3) related projects completed in the past seven (7) years. Section 6A is asking for a list of all construction projects currently being performed or performed in the last 10 years.
Q2. Please confirm what size the sewer is on this contract.
A2. New sewer 42”. CIP lined sewer 36”
Q3. Will Fairfax County consider lowering the qualification requirements to allow for more competition in the bid?
A3. No
Q4. Checking in to see if any Addendums and/or Pre-Qualification meeting minutes will be issued for Prequalification Accotink Gravity Sewer Improvements.
A4. Yes. This response is part of Addendum 1. See attached meeting minutes.
Q5. I assume the addenda will be provided on the Accotink Gravity Sewer Improvements
Project - Invitation for Pre-Qualification Public Works and Environmental Services site?
A5. Addenda will be posted to the same sites as the advertisement.
Attachment – 2/13/25 Non-Mandatory Meeting Minutes
END OF ADDENDUM NO. 1
COUNTY OF FAIRFAX, VIRGINIA
By:
Magdi S. Imbabi, Director, Wastewater Design and Construction Division Department of Public Works and Environmental Services
Date:
tgrala Text Box /S/ tgrala Text Box 2/18/25
C o u n t y o f F a i r f a x , V i r g i n i a
M E M O R A N D U M
Department of Public Works and Environmental Services
Wastewater Design and Construction Division
12000 Government Center Parkway, Suite 463
Fairfax, VA 22035
Phone: 703-324-5111, TTY: 1-800-828-1120, Fax: 703-324-3943 www.fairfaxcounty.gov/dpwes
Meeting Minutes
Meeting Date, Time: February 13, 2025, 10:00 AM
Fairfax County Teams Scheduled Meeting
Subject: Accotink Gravity Sewer Improvements (AGS)
Contractor Pre-Qualification Optional Meeting
Attendees: See attached list
PREPARED BY: Thomas Grala; 2/14/25.
Background
• Non-mandatory meeting as outlined in recently advertised Pre-Qualification materials for the above-mentioned project
• The AGS consists of approximately 15,000’ of new 42” pipe to be constructed by either open cut construction, or trenchless methods. The project also includes approximately 8,000’ of cured in place liner pipe.
• Contractors must be pre-qualified to bid on this project.
• Qualifications are due 2/27/25 at 1:00 PM.
Questions during the meeting:
Q. Is either email delivery, or hand delivery allowed?
A. Yes
Q. Related projects section indicated final completion vs. actual completion. What does this mean.
A. This relates to contractual completion vs. actual completion because of contractor schedule issues.
Q. Is an organization chart required for the whole company?
A. The organization chart provided should be for the division, or group, that would be responsible for the construction of the project should they be the successful bidder.
Q. What is needed for financial statements?
A. The requirements are as indicated in the application. They are to be supplied if requested.
Meeting Minutes- Accotink Gravity Sewer, 2/13/25 Meeting Minutes.
Q. Will material testing and inspection be the responsibility of the Contractor.
A. The requirements will be outlined in the project documents when the project is bid.
Q. Does the project have MBE requirements?
A. MBE/DBE requirements, if any, will be outlined in the project documents when bid.
Q. Will the project require a Project Labor Agreement?
A. No
Q. Do subcontractors need to provide qualifications?
A. No
List of Attendees:
Chris Nelsen
Delve Underground
610-246-4011
Bruce Junge
Northeast Remsco
Cell 732-921-5279
Tony Gutierrez
Sagres Construction Corporation
703-924-7220 estimating@sagresconstruction.com
Marissa Vona
Garney Construction
(703) 794-6189 mvona@garney.com
Jeff Hancher
Sherwin-Williams
(240)320-7880 cell jeffrey.w.hancher@sherwin.com
Aaron Tenney
Prism Contractors
757-874-5670 atenney@prismce.com
Tahmida Begum
Dulles Geotechnical and Material Testing Services phone:703 593 5716 tahmida@dullesgeotechnical.com
Brandon Reider
Garney Construction breider@garney.com
Stephen Thomas
Pleasants Construction sthomas@pleasantsconstruction.com mailto:estimating@sagresconstruction.com mailto:mvona@garney.com mailto:breider@garney.com mailto:sthomas@pleasantsconstruction.com
Lynne Giuliani
Am-Liner East, Inc.
office: 540-955-9671 lynne@amlinereast.com
Karlo Avila
Spiniello Companies
Phone 202-500-0068 kavila@spinielloco.com
Crystal Galvan
Inliner Solutions, LLC
678-436-6814 nebids@puriscorp.com
File details come from the government source that posted it. Updated .