Addendum Four.pdf

PDF 8 MB Posted

Attached to
RFB-150-25 EDU KSD Middleton Hall HVAC & Dorm Renovations
Solicitation number
RFB-785-2500000308-7
Issued by
Boyd County, Kentucky

About this file

This is Addendum Four issued by the Commonwealth of Kentucky Department for Facilities and Support Services Division of Engineering and Contract Administration for the Middleton Hall Dormitory Renovations & HVAC Bid Package 2 & 3 at the Kentucky School for the Deaf in Danville, Kentucky. The addendum moves the bid date to December 23, 2024 at 1:30 PM Eastern Time and provides extensive modifications to specifications including interior architectural wood casework, color schedules, tiling, suspended wood ceilings, signs, printed display materials, and gypsum board assemblies. The addendum also includes numerous drawing modifications related to fire ratings, demolition plans, site development, floor plans, enlarged floor plans, room finish schedules, and mechanical/electrical/plumbing specifications.

The addendum includes detailed technical specifications for materials like solid surface countertops, plastic laminate cabinets, wood casework, vinyl film graphics, and cast metal plaques. Significant modifications are made to door and frame schedules, changing many fire ratings from 45 minutes to 20 minutes and updating frame materials and types. The documents include multiple floor plans showing fire rating requirements, life safety plans, and enlarged floor plans with detailed mounting heights and accessibility requirements for restrooms and other facilities. The drawings indicate extensive renovations to living spaces, common areas, and support facilities within the dormitory building.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-150-25

FOR: Middleton Hall Dormitory Renovations & HVAC Bid Package 2 & 3 Kentucky School for the Deaf Danvillie, Kentucky

DATE: December 16, 2024

RFB-785-2500000308

ADDENDUM NO. Four (4)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.

Item 2: Official Bid date has been moved to December 23, 2024, at 1:30 P.M. Eastern Time

END OF ADDENDUM

Invitation to Bid No. RFB-150-25 For: Middleton Hall Dormitory Renovations & HVAC Bid Package 2 & 3 Kentucky School for the Deaf Danvillie, Kentucky

Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration

ADDENDUM No. 4

ADDENDUM NO. 4

TO THE DRAWINGS AND SPECIFICATIONS

FOR THE

KSD Middleton Hall Dorm Renovation

Danville, Kentucky

Account No. 540-CALK-SD19-00

RTA 23025

December 13, 2024

To All Plan Holders of Record:

This Addendum modifies bid documents dated 11/18/2024 for the above project and shall become part of said documents in the preparation of proposals and execution of work of the subject project.

General:

1. Owner will be responsible for all asbestos abatement.

Specifications:

1. Refer to Specification 064100 Interior Architectural Wood Casework.

a) Replace Specification in its entirety.

2. Refer to Specification 090050 Color Schedule.

3. Refer to Specification 093000 Tiling.

a) Refer to Part 2, Section 2.03 Tile Products, Paragraph F, Sub-Paragraph 4d – Add note “cove at base”

4. Refer to Specification 095426 – Suspended Wood Ceilings.

a) Refer to Part 2, Section 201 Acoustic Plank Wood Members and Suspension System, Paragraph

B – add Engineered Systems – Linea Ceiling and Wall System as an approved alternate.

5. Refer to Specification 101424 – Signs.

6. Refer to Specification 105000 – Printed Display Materials.

a) Add the entire specification section.

7. Refer to Specification 092116 - Gypsum Board Assemblies.

a) 2.03 Board Materials; Paragraph D

b) Add Item 5. Contractor option to use ½- inch lightweight Type C ceiling board or 5/8-inch regular type C ceiling board in areas designated to have a half-hour rated ceiling.

Drawings:

1. Insert Drawing Sheet G1.02 – Fire Rating Reference Plan.

a) Refer to attached Drawing Sheet G1.02.

2. Insert Drawing Sheet G1.03 – Fire Rating Reference Plan.

a) Refer to attached Drawing Sheet G1.03.

3. Refer to Drawing Sheet D1.01 – Ground & First Floor Demolition Plans.

a) Refer to Ground Floor Demolition Plan C/D1.01, Change Door Demolition Note from D-2 to

D-1 in the following rooms: Housekeeping 001, Linen 002, Laundry 003, Storage 006, Janitor

004.

b) Refer to First Floor Demolition Plan A/D1.01, Change Door Demolition Note from D-2 to D-1 in the following rooms: Housekeeping 101A, Housekeeping 101B, Linen 102A, Linen Storage

102B, Mech 104A, Mech 104B, Office 105A, Vending 106, Bath 128A and Living Room 138

(door adjacent to Stair S1).

4. Refer to Drawing Sheet D1.02 – Second Floor Demolition Plan.

a) Refer to Detail A/D1.02.

i) Add ‘Demolition Note C-1’ to Housing Keeping 201B

ii) Change Door Demolition Note from D-2 to D-1 in the following Rooms:

Housekeeping 201A, Housekeeping 201B, Linen Storage 202A, Linen Storage 202B, Mech 204A, and Mech 204B.

5. Refer to Drawing Sheet SD1.1 - Site Development and Layout Plan.

a) Revise tag “0b” to “1a” for new walk shown adjacent to the enlargement window.

b) Add “0b” tag indicating that adjacent walk is existing to remain.

6. Refer to Drawing Sheet A1.01 – Ground & First Floor Plan & Sheet A1.02 Second Floor Plan.

a) Refer to Drawing Sheets G1.2 Fire Rating Reference Plans and G1.3 Fire Rating Reference

Plans included in this Addendum for clarifications on required fire ratings.

b) Refer to General Notes.

i) Replace ‘Note 7’ as with the following:

7. ALL INTERIOR PARTITIONS ARE WALL TYPE '2' U.N.O.

c) Refer to Plan Notes.

i) Replace ‘Plan Note 3’ with the following:

"Provide abuse resistant gyp. bd. (092116.G) full height in Multi-Purpose Room

#119. Abuse resistant gyp bd to be installed on the elevated wall between the Multi-

Purpose Room #119 and Community Kitchen #118.”

ii) Add ‘Plan Note 11’ as follows:

“Provide brick infill at the existing wall where existing water fountains are being demolish. Refer to plumbing drawings for additional information.”

iii) Add ‘Plan Note 12’ as follows:

“Patch and repair wall to match adjacent surfaces where mechanical louver is to be abandoned, capped, and insulated within the exterior wall. Refer to Mechanical drawings for additional information.”

iv) Add ‘Plan Note 13’ as follows:

“New window sills will need to be cut to fil around existing columns supporting the window opening in Multi-Purpose Room #119 and Corridor CD2-B.”

v) Add ‘Plan Note 14’ as follows:

“Patch and repair wall to match adjacent finishes where existing Indicator of Class

Change/Door Bell and associated wall mounted light fixture is to be removed. At exterior walls patch will CMU infill toothed in and interior walls patch will be gypsum board. Refer to Electrical Drawings for additional Information.”

7. Refer to Drawing Sheet A1.01 – Ground & First Floor Plan.

a) Refer to Detail A/A1.01.

i) Add ‘Plan Note 3’ in Multi-Purpose Room #119 and Community Kitchen #118.

ii) Add ‘Plan Note 11’ in Vestibule VA.

iii) Add ‘Plan Note 12’ in Multi-Purpose Room #119.

(double height space at 2nd floor level)

iv) Add ‘Plan Note 13’ in Multi-Purpose Room #119 and Corridor CD2-B.

v) Add ‘Plan Note 14’ in all Living Rooms and Bed/Study rooms, typical all suites.

vi) Revise all instances of Wall Type 2B to Wall Type 2, except locations noted in

Community Kitchen 118 and Multi-Purpose 119.

vii) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the bottom of structure at all walls to create the 30-minute fire rating and demolish existing ceiling as required to allow for installation of the fire rated walls at the following rooms where rated demising walls occur:

a) Wall Between - Corridor CD1-B & Common Space 116

b) Wall Between - Corridor CD1-A & Commons 117

c) Wall Between – Bed/Study 113B & Break Room 116A

d) Wall Between – Mech 115 & Common Space 116

e) Wall Between - Conversation 117A & Living Room 130

f) Wall Between - Commons 117 & Living Room 121

g) Wall Between - Commons 117 & Restroom 103

viii) Add dimensions as illustrated on Sheet AD4.4.

ix) Revise handrail layout as illustrated on Sheet AD4.6.

x) Provide additional Wall Type 2 to top of wall to a height of approximately 36” to the ceiling as required to allow for installation of the fire rated walls at the following rooms:

Mech 105D-1, Mech 110D-1, Mech 115, Mech 124A, Mech 130C-1

xi) Add Wall Type 2B, full height behind new casework (kitchenette & bathroom vanities) full length of casework to route new plumbing and electrical items in the following rooms:

Living Room 113, Living Room 130

Refer to A2 Sheets & MEP Drawings for additional information. Where windows occur, furring will stop at T.O. window opening. New window sills will cover T.O. wall.

b) Refer to Detail B/A1.01.

i) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the bottom of structure at all walls to create the 30-minute fire rating and demolish existing

Mech 007C-1, Mech 010D-1

ii) Add ‘Plan Note 14’ in all Living Rooms and Bed/Study rooms, typical of all suites.

iii) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the ceiling as required to allow for installation of the fire rated walls at the following rooms where rated demising walls occur:

a) Wall Between - Corridor CA-001 & Passage 001

iv) Add Wall Type 2B, full height behind new casework (kitchenette & bathroom vanities) rooms:

Living Room 004, Living Room 007, Living Room 010, Living Room 011

8. Refer to Drawing Sheet A1.02 – Second Floor Plan.

a) Refer to Detail A/A1.02.

i) Add ‘Plan Note 14’ in all Living Rooms and Bed/Study rooms, typical of all suites.

ii) Add Wall Type 2B, full height behind new casework (kitchenette & bathroom vanities) rooms: Living Room 203 & Living Room 213

b) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the bottom of structure at all walls to create the 30-minute fire rating and demolish existing ceiling as required to allow for installation of the fire rated walls at the following rooms where rated demising walls occur:

i) Between - Corridor CD2-A & Common Space 201

ii) Between - Common Space 201 & Landry 202

iii) Between - Common Space 201 & Mech 203D-1

iv) Between - Corridor CD2-B & Commons 209

v) Between - Corridor CD2-B &Corridor CD2-C

c) Refer to A2 Sheets & MEP Drawings for additional information.

i) Revise all instances of Wall Type 2B to Wall Type 2, except locations noted in

Community Kitchen 118 and Multi-Purpose 119.

ii) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the bottom of structure at all walls to create the 30-minute fire rating and demolish existing

Mech 203D-1, Mech 208C-1, Mech 211D-1, Mech 216D-1

d) Revise handrail layout as illustrated on Sheet AD4.6.

e) Add Detail A/AD4.2 per attached Sheet AD4.2.

9. Refer to Drawing Sheet A1.03 – Enlarged Floor Plans.

a) Replace Sheet A1.03 in its entirety.

10. Refer to Drawing Sheet A1.04 – Elevator Plans, Sections, & Elevations.

a) Refer Details A/A1.04, B/A1.04, & C/A1.04.

i) Add the following note:

Note: Provide expansion joint covers per Specification Section 079513.A where new construction meets existing construction along Column Line B. Refer to

Specification Section 079513 for additional information.

b) Refer Detail A/A1.04. Add the following note:

Note: Refer to Specification Section 055000 for information on Elevator Ladder (055000.H).

Coordinate size location and clearances within elevator pit with elevator manufacturer.

c) Refer Detail H/A1.04. Add the following note:

Note: Refer to Specification Section 055000 for information on Elevator Sump Pit Cover

(055000.I). Coordinate size with elevator sump pit as required by elevator manufacturer.

11. Refer to Drawing Sheet A2.00 – Room Finish Schedule.

a) Replace Sheet A2.00 in its entirety.

12. Refer to Drawing Sheet A2.00a - Finish Legend.

a) Replace Sheet A2.00a in its entirety.

13. Refer to Drawing Sheet A2.00b – Interior Details.

a) Refer to Detail N/A2.00b – Revise dimension string from 2’-6” to “Varies, See Elevations”

b) Refer to Detail N/A2.00b – Add overall dimension to indicate “Existing soffit above wall cabinets to remain. Verify ceiling height prior to fabrication of casework. B.O. casework to remain 18” min. above countertop.”

14. Refer to Drawing Sheet A2.01 – Ground & First Floor – FF&E.

a) Refer to Detail C/A2.01 – Add “WG2” to existing door in Multi-Purpose Room 119

b) Refer to Detail C/A2.01 – In Living Room 004, 007, 010, and 011 add keynote “064100.C” to indicate new solid surface windowsills to be installed at existing windows.

15. Refer to Drawing Sheet A2.03 – Second Floor – FF&E.

a) Refer to Detail F/A2.02 – In Corridor CD2-B add keynote “064100.C” to indicate new solid surface windowsills to be installed at existing windows.

16. Refer to Drawing Sheet A2.04 – Ground & First Floor – Floor Pattern Plan.

a) Refer to Detail B/A2.04 – Add CPT3 at entry on landing between Ground Floor and First Floor.

Carpet to align with width of door and extend 3’-0” from entry door.

17. Refer to Drawing Sheet A3.01 - Roof Plan & Details.

a) Revise Detail G/A3.01 per attached Sheet AD4.1 & corresponding Detail A/AD4.1.

b) Revise Detail K/A3.01 per attached Sheet AD4.5 & corresponding Detail A/AD4.5.

c) Refer to Detail L/A3.01. Revise Material Reference 77100.A Fascia to 077100.B Coping.

d) Add Detail A/AD4.7 per attached Sheet AD4.7.

18. Refer to Drawing Sheet A6.01, Door and Frames Schedules – All Floors.

a) Refer to Comments Column:

i) Wherever the existing frame is indicated to remain, add the following verbiage: “Patch and repair existing frame as required to receive new hardware. Provide metal filling compound at all holes, sand smooth and repaint.”

ii) Where existing door and frame are indicated to remain, add the following verbiage:

“Remove all hinges, latch plates, closers, etc. Provide sheet metal infill for hinge mortices, latch plates and larger openings. Provide metal filling compound for holes. Sand to a smooth finish and paint”

19. Refer to Drawing Sheet A6.01 – Doors & Frames Schedule. Modify Door and Frame Schedules as indicated below:

a) Refer to the Door and Frame Schedule – Ground Floor:

i) Refer to Doors 002, 005, 006, 008, and 009:

ii) Change Frame Material from ETR to HM.

iii) Change Frame Type from ETR to 1A.

iv) Change Frame Head Detail from D/A6.01 to F/A6.01.

v) Change Frame Jamb Detail from E/A6.01 to G/A6.01.

vi) Change Fire-rating on these doors to 20 MIN.

vii) Delete the verbiage “ EXISITING FRAME TO REMAIN” from the Comments Column.

b) Refer to Doors 004, 007, 007C-1, 010, 010D-1, 011:

i) Change Fire-rating from 45 MIN to 20 MIN.

c) Refer to the Door and Frame Schedule – First Floor:

i. Refer to Doors 103, 106, 107, 111, 112, 122, 124, 126, 127, and 131:

1. Change Frame Material from ETR to HM.

2. Change Frame Type from ETR to 1A.

3. Change Frame Head Detail from D/A6.01 to F/A6.01.

4. Change Frame Jamb Detail from E/A6.01 to G/A6.01.

5. Change Fire-rating on these doors to 20 MIN.

6. Delete the verbiage “EXISTING FRAME TO REMAIN” from the Comments

Column.

ii. Refer to Doors 102, 104, 105, 106, 108, 109, 110, 110D-1, 113, 121, 124A.1, 124A.2, 125, 128, 129, 130, 130C-1, CD1-A.1, and CD1-B :

1. Change Fire-rating from 45 MIN to 20 MIN.

iii. Refer to Doors 100, 115.1, 115.2, 116A, 116B, 125D:

1. Change Fire-rating to non-rated.

b. Refer to the Door and Frame Schedule – Second Floor:

i. Refer to Doors: 201C, 204, 205, 210, 214, and 215:

1. Change Frame Material from ETR to HM.

2. Change Frame Type from ETR to 1A.

3. Change Frame Head Detail from D/A6.01 to F/A6.01.

4. Change Frame Jamb Detail from E/A6.01 to G/A6.01.

5. Change Fire-rating on these doors to 20 MIN.

6. Delete the verbiage “ EXISTING FRAME TO REMAIN” from the Comments

Column.

ii. Refer to Doors: 202, 203, 203D-1, 206, 207, 208, 208C-1, 211, 211D-1, 213, 216, 216D-

1, 217, CD2-A.1, and CD2-B.

1. Change Fire-rating from 45 MIN to 20 MIN.

iii. Refer to Doors: 200A, 201A, 201B,

1. Change Fire-rating to non-rated.

iv. Refer to Door CD2-C:

1. Add Frame Material HM.

2. Add Frame Type 1A.

3. Add Frame Head Detail F/A6.01.

4. Add Frame Jamb Detail G/A6.01.

5. Add Fire-rating of 20 MIN.

20. Refer to Sheet A7.01 – Ground & First Floor RCP Plan and Sheet A7.02 – Second Floor RCP Plan

a) Refer to Drawing Sheets G1.2 Fire Rating Reference Plans and G1.3 Fire Rating Reference

Plans included in this Addendum for clarifications on required fire ratings

b) Refer to RCP Notes.

i) Replace ‘RCP Note 2’ with the following:

“Gypsum Board Ceiling. Provide framing and supports as required. (092116).

Gypsum board ceilings will have a 30 Minute Fire Rating”

ii) Replace ‘RCP Note 9’ with the following:

“Existing gyp board ceilings in the units are 2 layers of 5/8" fire rated on a suspension system. Existing gyp board ceiling in each unit are to remain except where new MEP work is required. Install new layer of 1/2" gyp board. Reinstall existing ceiling mounted items that MEP indicate are to remain. Match existing finish and level of fire rating where applicable. Gypsum board ceilings will to have a 30 Minute Fire Rating.”

iii) Add ‘RCP Note 12’ as follows:

“Patch and repair existing vinyl soffit panels as required to demolish existing louver and install new louver. Refer to Mechanical Drawings for additional information.”

21. Refer to Sheet A7.01 – Ground & First Floor RCP Plan.

a) Refer to Detail A/A7.01.

i) Add ‘RCP Note 2’ in the following rooms, the ceiling in these locations will now be gypsum board in lieu of acoustical ceiling tile/grid: 107, 127, CD1-B, CD1-C.

ii) Add ‘RCP Note 9’ in the following rooms, the existing gypsum board ceiling will remain in lieu of acoustical ceiling tile/grid: 101, 103, 104, 106, 111, 112, 114, 123, 124, 126, 131, CD1-A

iii) Add ‘RCP Note #12’ to the underside of the exterior canopy, adjacent to the entry to

Vestible VA.

iv) Refer to attached Sheet AD4.3 and corresponding Detail A/AD4.3 for revisions to ceiling in Community Kitchen 118.

b) Refer to Detail B/A7.01.

i) Add ‘RCP Note 2’ in the following rooms, the ceiling will now be gypsum board in lieu of acoustical ceiling tile/grid: CA-002 in lieu of acoustical ceiling tile/grid: 002, 005, 006, 008, 009, CA-001

22. Refer to Sheet A7.02 – Second Floor RCP Plan.

a) Refer to Detail A/A7.02.

i) Add ‘RCP Note 2’ in the following rooms, the ceiling will now be gypsum board in lieu of acoustical ceiling tile/grid: 205, 210, CD2-B in lieu of acoustical ceiling tile/grid: 201C, 202, 204, 214, 215.

23. Refer to Sheet A7.03 – Enlarged Reflected Ceiling Plans.

a) Refer to Detail B/A7.03 - Extend gypsum board on soffits up to existing structure.

b) Refer to Detail C/A7.03 - Extend gypsum board on soffits up to existing structure.

Mechanical, Electrical, & Plumbing:

1. Refer to attached Addendum No. 4 from CMTA, Inc.

END OF ADDENDUM

RTA #23025

SPEC SECTION KEY FINISH DESCRIPTION (BASIS OF DESIGN)

ETR Existing To Remain

EXP Exposed To Structure

064100 HPL1 High Pressure Laminate Mfr.: Formica

Base & Wall Cabinets & Tall Color: Green Slate

Typical No: 8793

Used also in Div. 12 Finish: Matte

Location: Typical Suite Casework

HPL2 High Pressure Laminate Mfr.: Wilsonart

Color: River Cherry

No: 7937

Finish: To be selected from manufacturer's full finish range

Location: Community Kitchen

QZ1 Quartz Countertop Mfr.: Corian

Color: Graphite

Thickness: 3cm

Edge Profile: Eased Edge

Finish: Polished

Location: Community Kitchen

SS1 Solid-Surface Mfr.: Corian

Countertops Color: Deep Night Sky

Thickness: 1/2"

Edge Profile: Eased Edge

Location: Typical Suites

ADD #4 SS2 Solid-Surface Mfr.: Corian

Window Sills Color: Glacier White

Thickness: 1/2"

Edge Profile: Eased Edge

Location: Multi-Purpose Rooms

081416 WD1 Wood Veneer Face Manufacturer: Tbd

Door Color: Tbd

092116 FRP1 Fiberglass Reinforced Mfr.: Crane Composites

Panels Product: Standard FRP

Finish: Smooth

Color: White (85)

Location: Refer To Drawings

093000 CT1 Ceramic Tile Mfr.: Crossville

Floor Tile & Base - RRs Typ. Style: Argent 2.0

Color: ARG20 On the Rocks

Size: 12" x 24" at Floor; 6" x 12" at Base

Grout: Powergrout

Grout Mfr: TEC

Grout Color: To be selected from manufacturers full range

Installation: Monolithic

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

2 Provide Schluter Brushed Stainless Steel Cove Base Profile, -Dilex--Dilex-

AHK And All Associated Trim Pieces to Create a Full System At

Intersection Of Floor And Wall Tile

Location: Typical Suite Restrooms

CT2 Ceramic Tile Mfr.: Virginia Tile

Floor Tile & Base Style: Alterations

NOVEMBER 2024 KSD MIDDLETON HALL RENOVATION

FINISH LEGEND

All colors will be selected at a later date in a color board review meeting with the owner. Items listed below are basis of design only. The color board will be created and reviewed when all shop drawings and physical samples are received.

090050-1

Color: Cotton

Size: 12" x 24"

Grout: Powergrout

Grout Mfr: TEC

Grout Color: To be selected from manufacturers full range

Installation: Stack Bond

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

2 Provide Schluter Brushed Stainless Steel Cove Base Profile, -Dilex--Dilex-

AHK And All Associated Trim Pieces to Create a Full System At

Intersection Of Floor And Wall Tile

Location: Lobby

CT3 Ceramic Tile Mfr.: Virginia Tile

Floor Tile & Base Style: Alterations

Color: Light Thread

Size: 12" x 24"

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To be selected from manufacturers full range

Installation: Stack Bond

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

2 Provide Schluter Brushed Stainless Steel Cove Base Profile, -Dilex--Dilex-

AHK And All Associated Trim Pieces to Create a Full System At

Intersection Of Floor And Wall Tile

Location: Community Kitchen

CT4 Ceramic Tile Mfr.: Florida Tile

Typical Restroom Style: Fluent

Color: White (Glossy)

Size: 3" x 12"

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturers Full Range

Installation: See Interior Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

2 Provide Schluter Brushed Stainless Steel Cove Base Profile, -Dilex--Dilex-

AHK And All Associated Trim Pieces to Create a Full System At

Intersection Of Floor And Wall Tile

Location: Typical Restroom Wall Tile

CT5 Ceramic Tile Mfr.: Crossville

Accent Wall Tile Style: Cursive

Color: Old Denim

Size: 6" Triangle

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: Tbd

Installation: Stack Bond

Accessories: 1 Provide Schluter-Quadec Brushed Stainless Steel On All Outside

Corners.

Location: Suite Sink Walls, Accent Walls in public restrooms

CT6 Ceramic Tile Mfr.: Crossville

Accent Wall Tile Style: Cursive

Color: Old Denim

Size: 4" Circle

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Suite Sink Walls, Accent Walls in public restrooms

090050-2

CT7 Ceramic Tile Mfr.: Crossville

Accent Wall Tile Style: Cursive

Color: Old Denim

Size: 4-Corner

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Suite Sink Walls, Accent Walls in public restrooms

CT8 Ceramic Tile Mfr.: Crossville

Community Kitchen Field Tie Style: Cursive

Color: Soft Teal

Size: 3" x 6"

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Community Kitchen

CT9 Ceramic Tile Mfr.: Crossville

Typical Kitchen Accent Tile Style: Cursive

Color: Soft Teal

Size: 4" Circle

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Community Kitchen Accent Wall

CT10 Ceramic Tile Mfr.: Crossville

Accent Kitchen Tile Style: Cursive

Color: Goldenrod

Size: 4" Circle

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Community Kitchen Accent Wall

CT11 Ceramic Tile Mfr.: Crossville

Accent Kitchen Tile Style: Cursive

Color: Soft Teal

Size: 6" Triangle

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Community Kitchen Accent Wall

CT12 Ceramic Tile Mfr.: Crossville

Accent Kitchen Tile Style: Cursive

Color: Goldenrod

Size: 6" Triangle

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

090050-3

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Community Kitchen Accent Wall

CT13 Ceramic Tile Mfr.: Crossville

Accent Kitchen Tile Style: Cursive

Color: Goldenrod

Size: 4-Corner

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Community Kitchen Accent Wall

CT14 Ceramic Tile Mfr.: Crossville

Accent Kitchen Tile Style: Cursive

Color: Soft Teal

Size: 4-Corner

Grout: PowerGrout

Grout Mfr: TEC

Grout Color: To Be Selected From Manufacturer's Full Range

Installation: See Elevations

Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.

Location: Community Kitchen Accent Wall

095113 APC1 Acoustical Panel Ceiling Mfr.: Armstrong

Typical Style: School Zone Fine Fissured

No.: 1719

Size: 24" x 24" x 3/4"

Color: White

Edge: Angled Tegular

Grid: 9/16"

Location: Typical

Note: All Cut Tile Edges To Be Painted To Match Face Of Tile

095426 LWC1 Linear Wood Wall & Ceiling Mfr.: 9Wood

Systems Style: 3100 Acoustic Plank

No.: 3100

Size: 7-9/16" x 8'-0"

Finish: Fir Stain

Color: Cherry Veneer

Location: Multi-Purpose Room

096500 RT1 Resilient Tile Flooring: Mfr.: Tarkett

Rubber Tile Style: Color Splash

Color: VH1 Mariner

Size: 24x24

Installation: Monolithic

Location: Stair Landings

Finish: Hammered

096502 LVT1 Resilient Tile Flooring: Mfr.: Shaw

Luxury Vinyl Tile Style: Inlet II

Style Number: 4372V

Color: 72103 Valley

Wear Layer: 20mil

Size: 9" x 48"

Thickness: 5mm

Finish: Exoguard

Recommended

Adhesive:

Manufacturer's recommended adhesive

Antimicrobial: Manufacturer's recommended

Installation: Ashlar

090050-4

Location: Typical Suite

LVT2 Resilient Tile Flooring: Mfr.: Shaw

Luxury Vinyl Tile Style: Commingle

Style Number: 4350V

Color: Concrete 50105

Wear Layer: 20mil

Size: 9" x 48"

Thickness: 5mm

Finish: Exoguard

Recommended

Adhesive:

Manufacturer's recommended adhesive

Installation: Ashlar

Location: Corridors

LVT3 Resilient Tile Flooring: Mfr.: Shaw

Ground Floor Accent Style: Cove

Style Number: 0927V

Color: Wash 27436

Wear Layer: 20mil

Size: 9" x 48"

Thickness: 5mm

Finish: Exoguard

Recommended

Adhesive:

Manufacturer's recommended adhesive

Installation: Ashlar

Location: Ground Floor Accent, See Floor Pattern Plans

LVT4 Resilient Tile Flooring: Mfr.: Shaw

First Floor Accent Style: Cove

Style Number: 0927V

Color: Jade 27405

Wear Layer: 20mil

Size: 9" x 48"

Thickness: 5mm

Finish: Exoguard

Recommended

Adhesive:

Manufacturer's recommended adhesive

Installation: Ashlar

Location: First Floor Accent, See Floor Pattern Plans

LVT5 Resilient Tile Flooring: Mfr.: Shaw

Second Floor Accent Style: Cove

Style Number: 0927V

Color: Sapphire 27486

Wear Layer: 20mil

Size: 9" x 48"

Thickness: 5mm

Finish: Exoguard

Recommended

Adhesive:

Manufacturer's recommended adhesive

Installation: Ashlar

Location: Second Floor Accent, See Floor Pattern Plans

LVT6 Resilient Tile Flooring: Mfr.: Shaw

Multi-Purpose Room Style: Cast

Style Number: 4098V

Color: Instill 98585

Wear Layer: 20mil

Size: 24" x 24"

Thickness: 5mm

Finish: Exoguard

Recommended

Adhesive:

Manufacturer's recommended adhesive

090050-5

Installation: Ashlar

Location: Multi-Purpose Room

096513 RB1 Resilient Base & Accessories Mfr.: Tarkett

Rubber Wall Base Style: 6" Cove Base

Color: TG4 Black Magic

Height: 6"

Note: 1 Provide Cove At Floors With No Finish Or Resilient Finish.

2 Provide Straight At Carpet.

Location: Refer To Finish Schedule

RN1 Resilient Stair Nosing Mfr.: Tarkett

Stair Nosing Style: Johnsonite Stair Nosing RCN-XX-A

Color: 18 Navy

Location: First Floor Top of Stair Run

RN2 Resilient Stair Nosing Mfr.: Tarkett

Stair Nosing Style: Johnsonite Stair Nosing SCRN-XX-C

Color: 18 Navy

Location: Second Floor Top of Stair Run

RST1 Resilient Stair Tread & Riser Mfr.: Tarkett

Style: Stair Tread With Integrated Riser

Product Number: Colorsplash VIHNTRS

Texture: Hammered

Color: VH1 Mariner

Location: Existing Stairwells, Stair Landings

Note: Provide Vinyl Contrast Insert At Nosing

096813 CPT1 Carpet Tile Mfr.: Shaw

Collection: Haven

Style: Dwelling Tile

Style Number: 5T238

Color: Raven 38505

Size: 9" x 36"

Fiber: Ecosolution Q100 Nylon

Dye Method: 100% Solution Dyed

Backing: Synthetic/Ecoworx Tile

Installation: Monolithic

Location: Second Floor Corridor Common Space, Typical Office

CPT2 Carpet Tile Mfr.: Shaw

Collection: Haven

Style: Dwelling

Style Number: 5T497

Color: Mint 38327

Size: 9" x 36"

Fiber: Ecosolution Q100 Nylon

Dye Method: 100% Solution Dyed

Backing: Synthetic/Exoworx Tile

Installation: Ashlar

Location: Common Areas

CPT3 Carpet Tile Mfr.: Shaw

Walk-Off Carpet Collection: Steppin Out

Style: Welcome II

Style Number: 5T031

Color: Sterling 31557

Size: 24" x 24"

Fiber: Pet Polyester

Dye Method: 100% Solution Dyed

Backing: Polypropylene/Performance Rubber Backing

Installation: Monolithic

Location: Common Areas

098410 AWP3 Acoustical Wall Panel Mfr: Armstrong

Style: Soundscapes

090050-6

Size: Varies, Refer to Plans

Color: To be selected from manufacturer's full color range

Material: Mineral Fiber

Mounting: Drywall Clips

Location: Multi-Purpose Room

098436 AWP1 Acoustical Wall Panel Mfr: Soelberg Industries

Style: Muto Wall Panel

Size: 42" x 96" x 1/2"

Color: To be selected from manufacturer's full color range

Panl Pattern: Bomba

Material: 100% PET

Mounting: Direct Glue

Installation Direct Glue, Apply directly to existing brick

Location: First Floor Conversation Space, See FF&E Plans

AWP2 Acoustical Divider Screen Mfr: Soelberg Industries

Style: Muto Divider

Size: 48" x 96"

Color: Winter Water

Panel Pattern: Goccio

Material: 100% PET

Mounting: Provide Roller Track Installation

Location: First Floor Multi-Purpose Room, See FF&E Plans

099000 P1 Painting Mfr.: Sherwin Williams

Typical Paint Color: SW 7014 Eider White

Sheen: 1 Flat At Ceilings

2 Eggshell At Gypsum Walls

3 Semi-Gloss At Cmu Walls

4 Epoxy At All Damp/Wet/Kitchen/Trash/Pantry Locations - Walls And

Ceilings.

Location: Typical Wall Paint

P2 Painting Mfr.: Sherwin Williams

Ground Floor Accent Color: SW 9059 Silken Peacock

Sheen: 1 Eggshell At Gypsum Walls

2 Semi-Gloss At Hollow Metal Frames

Location: Refer to Room Finish Schedule and Floor Pattern Plans

P3 Painting Mfr.: Sherwin Williams

First Floor Accent Color: SW 6481 Green Bay

Sheen: 1 Eggshell At Gypsum Walls

2 Semi-Gloss At Hollow Metal Frames

Location: Refer to Room Finish Schedule and Floor Pattern Plans

P4 Painting Mfr.: Sherwin Williams

Second Floor Accent Color: SW 6524 Commodore

Sheen: 1 Eggshell At Gypsum Walls

2 Semi-Gloss At Hollow Metal Frames

Location: Refer To Supplemental Drawing #_

P5 Painting Mfr.: Sherwin Williams

Ceiling Paint Color: SW 7006 Extra White

Sheen: 1 Flat At Ceilings

2 Epoxy At All Damp/Wet/Kitchen/Trash/Pantry Locations - Walls And

Ceilings.

Location: See Finish Schedule

P6 Painting Mfr.: Sherwin Williams

Second Floor Accent Color: SW 9133 Jasper Stone

Sheen: 1 Eggshell At Gypsum Walls

Location: Second Floor Corridor Common Space, See FF&E Plan

P7 Painting Mfr.: Sherwin Williams

Bed/Study Accent Color: To be selected from manufacturer's full color range

Sheen: 1 Eggshell At Gypsum Walls

090050-7

Location: Bed/Study Room accent walls

P8 Painting Mfr.: Sherwin Williams

Hollow Metal Frames Color: SW 6993 Black of Night

Sheen: Semi-Gloss At Hollow Metal Frames

Location: Typical Hollow Metal Frame Paint

P9 Painting Mfr.: Sherwin Williams

Accent Color: SW 6769 Maxi Teal

Sheen: 1 Flat At Ceilings

2 Eggshell At Gypsum Walls

3 Semi-Gloss At Cmu Walls

4 Epoxy At All Damp/Wet/Kitchen/Trash/Pantry Locations - Walls And

Ceilings.

Location: Multi-Purpose Room Niche Accent

P10 Painting Mfr.: Sherwin Williams

Accent Color: SW 6480 Lagoon

Sheen: 1 Flat At Ceilings

2 Eggshell At Gypsum Walls

3 Semi-Gloss At Cmu Walls

4 Epoxy At All Damp/Wet/Kitchen/Trash/Pantry Locations - Walls And

Ceilings.

Location: Community Kitchen Accent

SC1 Applied Concrete Coating Mfr.: Refer To 033000 Cast In Place Concrete

Product: Refer To 033000 Cast In Place Concrete

Location: General

Note: 1 Provide Appropriate Transition At Door Threshold

2 Usda Approved Sealer

101101 MB1 Visual Display Boards Mfr.: Claridge

Markerboard Surface: Porcelain

Color: White

Size: Varies; Refer To Equipment Legend

Accessories Stadium Marker Caddy MGM-MC1-L

Location: Refer To Floor Plans

TB1 Visual Display Boards Mfr.: Claridge

Cork Bulletin Board Surface: Cork Bulletin Board

Color: 111 Smoke

Size: 4' x 8'

Location: Refer To Floor Plans

101424 Signs Mfr: Asi Signage

Room Signage Background Color: Tbd

Copy Color: Tbd

Size: 8" X 8"

Location: Typical

Signs Mfr: Asi Signage

Directional Signage Background Color: Tbd

Copy Color: Tbd

Size: 18"W X 20"H

Location:

Signs Mfr: Asi Signage

Flat Cut Acrylic Numbers Copy Color: Tbd

Size: 3' - 0" High

Location: Refer to plans

ADD #4 WG1 Vinyl Window Film Mfr: 3M

One-Way/Mirrored Type: Mirrored/One-Way

Size: Verify with Window on Door dimensions

Location: Refer to plans

090050-8

102600 CG1 Wall & Corner Guards Mfr.: Inpro

Product: 160 High Impact Corner Guard

Height: Tbd (4' (1.22M), 8' (2.44M), 9'(2.74M), 12' (3.66M))

Vinyl Cover: .080" (2Mm)

Vinyl Retainer: .070 (1.8Mm)

Color: 0380 Gala

Installation: Mechanically Fastened Vinyl Retainer

Accessories: Top/Bpottom Caps

Location/Qty: All Outside Gyp Corners

CG2 Wall & Corner Guards Mfr.: Inpro

Product: 160 High Impact Corner Guard

Height: Tbd (4' (1.22M), 8' (2.44M), 9'(2.74M), 12' (3.66M))

Vinyl Cover: .080" (2Mm)

Vinyl Retainer: .070 (1.8Mm)

Color: To be selected from manufacturer's full color range

Installation: Mechanically Fastened Vinyl Retainer

Accessories: Top/Bpottom Caps

Location/Qty: Multi-Purpose Room

CG3 Wall & Corner Guards Mfr.: Inpro

High Impact End Wall Protector Product: 160DBN Blunose High Impact End Wall Protector

Height: Tbd (4' (1.22M), 8' (2.44M), 9'(2.74M), 12' (3.66M))

Vinyl Cover: .080" (2Mm)

Vinyl Retainer: .070 (1.8Mm)

Color: 0152 Black

Installation: Mechanically Fastened Vinyl Retainer

Accessories: Top/Bpottom Caps

Location/Qty: Bed/Study Room Entries, Refer to Drawings

CG4 Wall & Corner Guards Mfr.: Inpro

High Impact End Wall Protector Product: 160DBN Blunose High Impact End Wall Protector

Height: Tbd (4' (1.22M), 8' (2.44M), 9'(2.74M), 12' (3.66M))

Vinyl Cover: .080" (2Mm)

Vinyl Retainer: .070 (1.8Mm)

Color: 0380 Gala

Installation: Mechanically Fastened Vinyl Retainer

Accessories: Top/Bpottom Caps

Location/Qty: Refer to Drawings

ADD #4 105000 WG2 Printed Display Material Manufacturer: Lynn Monster Color

Vinyl Window Graphic Graphic: Custom Graphic

Substrate TBD

Finish: TBD

Size: Verify size with existing door to remain

Note: Graphics to be provided at a later date

102800 Toilet And Bath Accessories Refer To Drawings

105723 CWS1 Mfr.: Closetmaid

Closet Wire Shelving Color: White

Finish: Poly Coated Wire Shelving

Depth: 16"

Location: Refer To Drawings

122413 RWS1 Manual Window Shades Mfr.: Draper

Roller Window Shades Shade Fabric: Sheerweave

Single Shade Openness Factor: 1%

Color: Tbd

Fascia: Clear Anodized

Location: Suites

Notes: 1 Provide Cluth Mechanism

RWS2 Manual Window Shades Mfr.: Draper

Roller Window Shades Shade Fabric 1: Sheerweave

090050-9

Double Shade Shade Fabric 2: Light Blocking

Openess Factor: 1 Shade 1: 1%

2 Shade 2: Opaque

Color: Tbd

Fascia: Clear Anodized

Location: Typical

RWS3 Manual Window Shades Mfr.: Draper

Blackout Roller Window Shades Shade Fabric: True Blackout with Side Channels

Single Shade Openness Factor: Opaque

Color: Tbd

Fascia: Clear Anodized

Edges: Blackout Side Channels

Location: Sensory Room, Refer to Drawings

Notes: 1 Provide Cluth Mechanism

124930 RWS4 Window Shade Mfr.: Draper

Motorized (Blackout) Shade Fabric: True Blackout with Side Channels

Openness Factor: Opaque

Color: Tbd

Fascia: Clear Anodized

Location: Multi-Purpose Room

142010 HPL4 High Pressure Laminate Mfr.: Kone

Elevator Cab Color: To be selected from manufacturer's full range

No: To be selected from manufacturer's full range

Finish: To be selected from manufacturer's full range

Location: Elevator Cab

090050-10

Account No. 540-CALK-SD19-00

SIGNS 101424 - 1

SECTION 101424

SIGNS

PART 1 GENERAL

1.01 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Special Conditions and

Division 1 Specification Sections, apply to this Section.

B. Division 9 Section 090050 - Finish Legend

1.02 SUMMARY

A. This Section includes the furnishing of Specialty Signs. Extent of Specialty Signs is shown on the

Drawings and in this section.

B. Forms of Specialty Signs required include the following:

1. Interior Panel signs (mechanical attachment)

2. Flat cut acrylic letters

3. Tactile Exit Signs

4. ADD #4 - Vinyl film graphics

5. ADD #4 - Cast metal plaques

C. Work not included in this section:

1. Illuminated exit signs are specified in Division 16.

2. Handicapped parking signs are specified in Division 10 - Exterior Post & Panel Signs.

3. Exterior post and panel signs are specified in Division 10 - Exterior Post and Panel Signs.

1.03 SUBMITTALS

A. General: Submit the following in accordance with Conditions of the Contract and Division 1

Specification Sections.

B. Product Data: Include manufacturer's construction details relative to materials, dimensions of individual components, profiles, and finishes for each type of sign required.

C. Shop Drawings: Provide shop drawings for fabrication and erection of signs. Include plans, elevations, and large-scale sections of typical members and other components. Show anchors, grounds, reinforcement, accessories, layout, and installation details.

1. Provide message list for each sign required, including large-scale details of wording and layout of lettering.

2. For signs supported by or anchored to permanent construction, provide setting drawings, templates, and directions for installation of anchor bolts and other anchors to be installed as a unit of Work in other Sections.

3. Samples: Provide the following samples of each sign component for initial selection of color, pattern and surface texture as required and for verification of compliance with requirements indicated.

a. Samples for verification of color, pattern, and texture selected, and compliance with requirements indicated:

1) Panel Sign Cast Acrylic Sheet and Plastic Laminate: Provide a sample panel not less than 8-1/2 inches by 11 inches for each material indicated.

Include a panel for each color, texture, and pattern required. On each panel include a representative sample of the graphic image process required, showing graphic style, and colors and finishes of letters, numbers, and other graphic devices.

SIGNS 101424 - 2

1.04 QUALITY ASSURANCE

A. Single-Source Responsibility: For each separate type of sign required, obtain signs from one source from a single manufacturer.

B. Design Criteria: The drawings indicate size, profiles, and dimensional requirements of signs and are based on the specific type and model indicated. Signs by other manufacturers may be considered provided that deviations in dimensions and profiles are minor and do not change the design concept as judged by the Architect. The burden of proof of equality is on the proposer.

C. ADA Regulations: All signage specified herein shall comply with the minimum sign requirements as outlined by the most current Americans with Disabilities Act (ADA).

1. Manufacturer shall be responsible for complying with all applicable requirements of ADA whether specifically specified or not. Notify Architect of any discrepancies between ADA requirements and the contract documents.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, provide products of one of the following:

1. Manufacturers of Interior Panel Signs:

a. APCO Architectural Sign Systems

b. ASI Modulex

c. Best Manufacturing Co.

d. Contemporary Plastics, Inc.

e. Fastsigns of Louisville

f. Innerface Sign System

g. Inpro

h. J. Gemini, Inc.

i. Mohawk Signs

j. Nelson-Harkins

k. Serigraphics Sign Systems, Inc.

l. Signcraft

2. Manufacturers of Fabricated Letters :

a. APCO Architectural Sign Systems

b. ASI Modulex

c. Best Manufacturing Co.

d. Contemporary Plastics, Inc.

e. Fastsigns of Louisville

f. Innerface Sign System

g. Inpro

h. J. Gemini, Inc.

i. Mohawk Signs

j. Nelson-Harkins

k. Serigraphics Sign Systems, Inc.

l. Signcraft

3. ADD #4 - Manufacturers for Vinyl Film Graphics

a. 3M (Basis of Design)

2.02 MATERIALS

A. Cast Acrylic Sheet: Provide cast (not extruded or continuous cast) methyl methacrylate monomer plastic sheet, in sizes and thicknesses indicated, with a minimum flexural strength of 16,000 psi when tested in accordance with ASTM D 790, a minimum allowable continuous service temperature of 176 deg F (80 deg C), and of the following general types:

SIGNS 101424 - 3

1. Opaque Sheet: Where sheet material is indicated as "opaque," provide colored opaque acrylic sheet in colors and finishes as selected from the manufacturer's standards.

2. ABS Plastic: Provide high-impact thermoplastic composed of copolymers of acrylonitrile, butadiene, and styrene.

3. ADD #4- Vinyl Film: Provide vinyl film signage and graphics as manufactured by 3M’s films or approved equivalent.

a. Mirrored Graphic Films

2.03 PANEL SIGNS

A. Panel Signs: Comply with requirements indicated for materials, thicknesses, finishes, colors, designs, shapes, sizes, and details of construction.

1. Produce smooth, even, level sign panel surfaces, constructed to remain flat under installed conditions within a tolerance of plus or minus 1/16 inch measured diagonally.

2. Material: Plastic

3. Corner Condition: Square corners

4. Panel Thickness: 1/8" minimum

5. Attachments: Mechanical

6. Size: 8" x 8"

7. Copy: Final signage copy shall be provided on the shop drawings; for bidding purposes the bidder shall assume that the room name(s) and their three digit room numbers shall be listed.

8. Where panel signs are indicated to be mounted to window surfaces, the signage fabricator shall provide a matching blank backer panel.

B. Graphic Content and Style: Provide sign copy that complies with the requirements indicated for size, style, spacing, content, position, material, finishes, and colors of letters, numbers, and other graphic devices.

C. Raised Copy: Provide sign plaque with raised copy (1/32") and grade 2 braille as an integral part of the plaque. Use photo etching process or reverse engraved process. Other methods to achieve raised and braille will require pre-approval. Sign surface color must be durable and scratch and vandal resistant. Applied copy and braille strips are not acceptable.

D. Room Number and Title: Titles shall be 3/4" Sans Serif Typestyle, centered horizontally and vertically. Numbers shall be 2" Sans Serif Typestyle, centered horizontally and vertically.

E. Changeable Message Inserts: Fabricate signs to allow insertion of 1" x 8" changeable messages in the form of transparent covers with paper inserts printed by Owner.

1. Furnish insert material and software for creating text and symbols for PC-Windows computers for Owner production of paper inserts.

F. Special Symbols: Handicap symbol shall be 3" high. Men/Women symbols shall be 4" high. Locate as directed by Architect.

1. Equivalent raised written description must be placed directly below symbol.

G. See room finish schedule for sign locations and copy. Size shall be nominal 8" x 8" or as indicated.

Manufacturer's standard sizes incorporating minor size variations will be accepted.

2.04 FLAT CUT ACRYLIC LETTERS AND NUMBERS

A. Flat Cut Letters: Produce characters with smooth, flat faces, sharp corners, and precisely formed lines and profiles, free from pits, scale, sand holes, or other defects. Attach lugs onto back of characters and tap to receive threading mounting studs. Comply with requirements indicated for finish, style and size.

1. Thickness: 1/4"

2. Style: To be selected from manufacturer's full range

3. Mounting: Two part epoxy

4. Copy: Varies, Refer to sheet A2 sheets

SIGNS 101424 - 4

2.05 ADD #4 - CAST METAL PLAQUES

A. Plaques: Castings shall be free from pits, scale, sand holes, or other defects. Comply with requirements specified for metal, border style, background texture, and finish and with requirements shown for thickness, size, shape, and copy. Hand-tool and buff borders and raised copy to produce the manufacturer's standards satin polished finish. Refer to "Finish" article for other finish requirements.

1. Metal: Aluminum

2. Border Style: As selected by Architect/ Designer

3. Background Texture: Manufacturer's standard pebble texture

4. Background Finish: Provide the manufacturer's standard baked enamel finish

5. Layout: Refer to plaque layout on sheet A2.00

6. Size:

2.06 ADD #4 - VINYL FILM

A. Vinyl Film: Provide vinyl film signage and graphics as manufactured by 3M's films or approved equivalent.

1. Mirrored Graphic Films

a. Apply Graphic in a manner in which occupants in Sensory 116B cannot see into

Common Space 116.

2. Size: Match size of window on Sensory 116B Door

2.07 FABRICATION - GENERAL

A. General: Comply with requirements indicated for materials, thicknesses, finishes, colors, designs, shapes, sizes, and details of construction.

B. Design, fabricate, and install sign assemblies to prevent buckling, opening up of joints, and over-stressing of welds and fasteners.

C. Mill joints to a tight, hairline fit. Form joints exposed to the weather to exclude water penetration.

D. Conceal fasteners if possible; otherwise, locate fasteners where they will be inconspicuous.

E. Create signage to required sizes and layout. Comply with requirements indicated for design, dimensions, finish, color, and details of construction.

2.08 FINISHES

A. Colors and Surface Textures: For exposed sign material that requires selection of materials with integral or applied colors, surface textures or other characteristics related to appearance, provide color matches indicated, or if not indicated, as selected by the Architect from the manufacturer's standards.

PART 3 EXECUTION

3.01 INSTALLATION

A. General: Locate sign units and accessories where indicated, using mounting methods of the type described and in compliance with the manufacturer's instructions.

1. Install signs level, plumb, and at the height indicated, with sign surfaces free from distortion or other defects in appearance.

B. Wall Mounted Panel Signs: Attach panel signs to wall surfaces using the methods indicated below:

1. Mounting: Use expansion bolt anchoring device as recommended by manufacturer to attach signs to concrete block walls. Provide minimum 4 fasteners for 8" x 8" signs.

2. Mount interior signs with centerline one foot from latch side of door frames, and top of sign five feet above finish floor. Note: Lower signs as required to meet all ADA requirements.

3. Where there is no wall space to the latch side of the door, including at double leaf doors, signs shall be placed on the nearest adjacent wall. Mounting location for such signage shall

SIGNS 101424 - 5

be so that a person may approach within 3 inches (76 mm) of signage without encountering protruding objects or standing within the swing of a door.

4. Where a tactile sign is provided at a door, the sign shall be alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leaves, the sign shall be to the right of the right-handed door. Where there is no wall space on the latch side of a single door, or to the right side of double doors, signs shall be on the nearest adjacent wall. Signs containing tactile characters shall be located so that a clear floor area 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.

5. Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character.

C. Dimensional Letters and Numbers: Mount letters and numbers using standard fastening methods recommended by the manufacturer for letter form, type of mounting, wall construction, and condition of exposure indicated. Provide heavy paper template to establish letter spacing and to locate holes for fasteners. Locate as directed by Architect.

1. Flush Mounting: Mount letters with backs in contact with the wall surface.

D. ADD #4 - Cast Metal Plaques: Mount Plaques using the standard method recommended by the manufacturer for the type of wall surface indicated.

3.02 CLEANING AND PROTECTION

A. At completion of the installation, clean soiled sign surfaces in accordance with the manufacturer's instructions. Protect units from damage until acceptance by the Owner.

3.03 SIGNAGE SCHEDULE

A. See attached signage schedule.

ADD #4 - PRINTED DISPLAY MATERIALS 105000 - 1

SECTION 105000

ADD #4 - PRINTED DISPLAY MATERIALS

PART 1 - GENERAL

1.01 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Special Conditions and

Division 1 Specification Sections, apply to this Section.

B. Division 9 Section 090050 - Finish Legend

1.02 SUMMARY

A. WG2 - Perforated vinyl window graphic for installation on window surfaces.

1. Printing Method: Direct substrate printing utilizing HPLX 600 UV Printer

2. Substrate: Vinyl perforated material 65/35 hole pattern.

3. Image: High resolution PDFs will be provided by Owner. Single-sided printing required.

4. Mounting: Mount graphics directly on window glazing surfaces.

1.03 SUBMITTALS

A. Shop Drawings: Detail fabrication and installation of the printed display items and hardware. Include printed strike-off, and details of hardware components and their connections.

1.04 QUALITY ASSURANCE

A. Fabricator Qualifications: A firm experienced in producing printed display materials similar to those indicated for this Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units.

1.05 DELIVERY, STORAGE, AND HANDLING

A. Deliver printed display materials wrapped in protective coverings and strapped together in suitable packs or in heavy-duty cartons.

B. Store products on elevated platforms in a dry location.

1.06 PROJECT CONDITIONS

A. Field Measurements: Where printed display materials are indicated to fit to other construction, verify dimensions of other construction by field measurements before fabrication and indicate measurements on Shop Drawings. Coordinate fabrication schedule with construction progress to avoid delaying the

Work.

1. Established Dimensions: Where field measurements cannot be made without delaying the

Work, establish dimensions and proceed with printing without field measurements.

Coordinate cutting of materials to ensure that actual dimensions correspond to established dimensions.

PART 2 - PRODUCTS

2.01 MANUFACTURERS

A. Available Manufacturers: Subject to compliance with requirements, provide products by one of the following, or approved equivalent:

1. ASI Signage Innovations

2. Fastsigns of Louisville

3. Lynn Imaging

2.02…

This is the start of the file's text. The full file is on GovTribe.