This is an Addendum #1 to the contract documents for the GISD Davis Building HVAC Replacement project, issued by Clark Trombley Randers Consulting Engineers on December 19, 2019, for the Genesee Intermediate School District. The addendum modifies the original contract documents and requires bidders to acknowledge receipt by noting the addendum number and issue date on their bid forms, with failure to do so potentially resulting in disqualification. The project involves HVAC system replacement work, with base bid work scheduled during evening hours from 3:30 pm to 11:30 pm. Key mechanical specifications include VRF (Variable Refrigerant Flow) equipment installation with specific ambient temperature, BTU output, and line length requirements; retention of the existing boiler and loop pumps with removal of only the cooling tower; and provisions for Zoomlock fittings that may affect equipment warranty depending on installer capabilities and manufacturer approval. Bidders using Mitsubishi Electric Trane equipment must provide a TAR-CT01MAU-SB TOUCH MA CONTROLLER thermostat, while those using alternative VRF suppliers must provide equivalent thermostats. Control wiring for Mitsubishi systems must be 16-2 stranded and shielded, and filter boxes should be furnished by the VRF manufacturer or contractor-supplied as pre-fabricated or custom-fabricated units.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Clark Trombley Randers Consulting Engineers

ADDENDUM #1 (12/13 REBID)

Date: December 19, 2019CTR Project Number: 19027.00

Project Name: GISD Davis Building HVAC Replacement

Client: Genesee Intermediate School District

This addendum forms a part of the Contract Documents and modifies the original Contract Documents. Acknowledge receipt of this Addendum by inserting the number and issue date of this addendum in the blank space provided on the Bid Form. Failure to do so may subject the Bidder to disqualification.

This Addendum consists of one (1) page plus one (1) attachment:

December Pre-bid sign in sheet (1) sheet.

Thermostat cut sheet (2) sheets.

GENERAL

1. Base bid should plan on working hours of 3:30 pm – 11:30 pm.

MECHANICAL

1. Attached is additional information on the VRF equipment including ambient temperatures, BTU outputs and line lengths.

2. The boiler and loop pumps are to be left in place. Only the cooling tower is to be removed.

3. Zoomlock fittings may affect the equipment/system warranty. They are very sensitive to installer capabilities. Consult with your selected manufacturer to see if they are allowed without compromising the warranty.

4. If using Mitsubishi Electric Trane, provide the TAR-CT01MAU-SB TOUCH MA CONTROLLER thermostat. If using another VRF supplier, provide a similar thermostat.

5. Control wiring for the Mitsubishi Electric Trane system is to be 16-2 stranded and shielded.

6. Filter box should be furnished by VRF manufacturer. If not possible, contractor should purchase a pre-fabricated filter box or fabricate a filter box.

END OF ADDENDUM NO. 1

Accessibility Report

Filename:

Addendum .pdf

Report created by:

Organization:

[Enter personal and organization information through the Preferences > Identity dialog.]

Summary

The checker found no problems in this document.

Needs manual check: 0

Passed manually: 2

Failed manually: 0

Skipped: 1

Passed: 29

Failed: 0

Detailed Report

Document

Rule Name Status Description

Accessibility permission flag Passed Accessibility permission flag must be set

Image-only PDF Passed Document is not image-only PDF

Tagged PDF Passed Document is tagged PDF

Logical Reading Order Passed manually Document structure provides a logical reading order

Primary language Passed Text language is specified

Title Passed Document title is showing in title bar

Bookmarks Passed Bookmarks are present in large documents

Color contrast Passed manually Document has appropriate color contrast

Page Content

Rule Name Status Description

Tagged content Passed All page content is tagged

Tagged annotations Passed All annotations are tagged

Tab order Passed Tab order is consistent with structure order

Character encoding Passed Reliable character encoding is provided

Tagged multimedia Passed All multimedia objects are tagged

Screen flicker Passed Page will not cause screen flicker

Scripts Passed No inaccessible scripts

Timed responses Passed Page does not require timed responses

Navigation links Passed Navigation links are not repetitive

Forms

Rule Name Status Description

Tagged form fields Passed All form fields are tagged

Field descriptions Passed All form fields have description

Alternate Text

Rule Name Status Description

Figures alternate text Passed Figures require alternate text

Nested alternate text Passed Alternate text that will never be read

Associated with content Passed Alternate text must be associated with some content

Hides annotation Passed Alternate text should not hide annotation

Other elements alternate text Passed Other elements that require alternate text

Tables

Rule Name Status Description

Rows Passed TR must be a child of Table, THead, TBody, or TFoot

TH and TD Passed TH and TD must be children of TR

Headers Passed Tables should have headers

Regularity Passed Tables must contain the same number of columns in each row and rows in each column

Summary Skipped Tables must have a summary

Lists

Rule Name Status Description

List items Passed LI must be a child of L

Lbl and LBody Passed Lbl and LBody must be children of LI

Headings

Rule Name Status Description

Appropriate nesting Passed Appropriate nesting

Back to Top

File details come from the government source that posted it. Updated .