Addendum _3.pdf
PDF 5 MB Posted
- Attached to
- Griffin Golf Course Bridge Replacements
- Solicitation number
- PE-72650-NONST-2024-000000004
- Issued by
- Taliaferro County, Georgia
About this file
This document is an Addendum for the Griffin Golf Course Bridge Replacements project in Griffin, Georgia, issued by Paragon Consulting Group, Inc. on behalf of the City of Griffin.
The Addendum modifies the original Bidding Documents and includes a revised Bid Tabulation, updated contract drawings for Bridge A and Bridge B, contact information for the gabion supplier, and a revised plan sheet. Key changes include adjustments to quantities for certain line items, the addition of a new "Trench Rock" line item, and the removal of a guard rail line item for Bridge B. The deadline for submitting bids is March 14, 2024. The Addendum also provides detailed specifications and requirements for the Aluminum Box Culvert assembly, engineered backfill material, and placement procedures.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Advertisement for Bidders_.pdf | ||
| Addendum _4.pdf | ||
| Addendum _2.pdf | ||
| Addendum _1.pdf | ||
| Pre_BID Meeting_Sign in Sheet_2_27_2024.pdf | ||
| NOIA (Notice of Intent to Award)_ 24_007 Golf.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CITY OF GRIFFIN
GRIFFIN GOLF COURSE BRIDGE REPLACEMENTS
BID # 24-007
FROM: PARAGON CONSULTING GROUP, INC.
350 AIRPORT ROAD
GRIFFIN, GA 30224
TO: ALL BIDDERS OF RECORD
RE: Addendum No. 3, dated March 14, 2024
This Addendum forms a part of the Contract Documents and modifies the original Bidding
Documents dated February 2024.
This Addendum consists of two (2) pages, a revised Bid Tabulation consisting of four (4) pages, Contech Contract Drawings titled “Griffin Golf Course Bridge A” consisting of sixteen (16) pages, Contech Contract Drawings titled “Griffin Golf Course Bridge B” consisting of sixteen (16) pages, contact information for Adam Pierce, CPESC from Solmax consisting of one (1) page, and a revised plan sheet No. 20 consisting of one (1) page.
CONTRACT DOCUMENTS AND SPECIFICATIONS
Add. 1.1 Modification: A revised Bid Tabulation dated March 14, 2024, is attached to this
Addendum and becomes a part of the Contract Documents. All Bidders should use the revised Bid Tabulation when submitting a bid.
Add. 1.2 Modification: The quantity of line item ‘G.A.B. IN PLACE FOR BACKFILL OF
CULVERT & WINGWALLS’ has been changed to 591 TN. This change applies to the Bid Tabulation for Bridge A.
Add. 1.3 Modification: The quantity of line item ‘G.A.B. IN PLACE FOR BACKFILL OF
CULVERT & WINGWALLS’ has been changed to 618 TN. This change applies to the Bid Tabulation for Bridge B.
Add. 1.4 Modification: The line item ‘TRENCH ROCK’ has been added to the Bid Tabulation with a quantity of 10 CY. This change applies to the Bid Tabulation for both
Bridge A and Bridge B.
Add. 1.5 Modification: The line item ‘G.D.O.T. STANDARE W BEAM GUARD RAIL &
SUPPORTS WITH REFLECTROS COMPLETE’ has been removed from the Bid
Tabulation for Bridge B.
Add. 1.6 Modification: Contech Contract Drawings titled ‘Griffin Golf Course Bridge A’ are attached to this Addendum and becomes a part of the Contract Documents.
Add. 1.7 Modification: Contech Contract Drawings titled ‘Griffin Golf Course Bridge B’ are attached to this Addendum and becomes a part of the Contract Documents.
Add. 1.8 Modification: Contact information for Adam Pierce, CPESC from Solmax is attached to this Addendum. Solmax will be providing the Gabions for both Bridge
A and Bridge B.
Add. 1.9 Modification: Plan sheet No. 20 has been revised and is attached to this
Addendum and becomes part of the Contract Documents.
End of Addendum No. 3
Item Description Unit Quantity Unit Price Item Total
BRIDGE A
GENERAL
1. PAYMENT & PERFORMANCE BONDS LS 1
2. GENERAL CONDITIONS LS 1
3. CONSTRUCTION STAKING BY REGSITERED SURVEYOR LS 1
4. AS-BUILT SURVEY BY REGISTERED SURVEYOR LS 1
DEMOLITION/REMOVAL
5. COMPLETE DEMOLITION OF EXISTING CONCRETE BRIDGE INCLUDING OFFSITE DISPOSAL LS 1
6. SAW CUT ASPHALT (VARIOUS DEPTHS) LF 130
7. REMOVAL OF ASHPALT PAVING COMPLETE INCLUDING OFFSITE DISPOSAL (VARIOUS THICKNESSES) SY 163
8. REMOVAL OF DEBRIS AND CONCRETE IN STREAM LS 1
9. REMOVAL OF EXISTING GATES & POSTS LS 1
10. REMOVAL & DISPOSAL OF CONCRETE POURED WALL SECTION (VERTICAL SAW CUT INCLUDED) LS 1
11. REMOVAL & DISPOSAL OF STACKED CONCRETE WALL SECTION LS 1
NEW STRUCTURE - CONTECH ALUMINUM BOX CULVERT #51
12. ALUMINUM BOX CULVERT ASSEMBLY & INSTALLATION INCLUDING ALUMINUM WING WALLS COMPLETE LS 1
13. ALUMINUM BOX CULVERT FOUNDATION SYSTEM COMPLETE PER PLANS LS 1
14. PREPARATION FOR INSTALLATION OF CONTECH STRUCTURE, WING WALL EMBEDMENT & TIE BACKS LS 1
15. #4 STONE FOR FOUNDATION BASE TN 35
16. G.A.B. IN PLACE FOR BACKFILL OF CULVERT & WINGWALLS TN 591
17. ASPHALT PAVING (6 : 2 : 1 1/2) SECTION) SY 163
18. GRADING COMPLETE (TOPSOIL & FINE GRADING) LS 1
ASPHALT PAVING & CONCRETE FLATWORK
19. 8" REINFORCED CONCRETE BRIDGE SLAB INCLUDING REINFORCING PER DETAIL SF 540
20. 32" TALL CONCRETE BARRIER LF 56
21. CONCRETE CURB AT BASE OF BARRIER ON BRIDGE LF 56
22. CONCRETE AT CART PATH - 5" THICK SF 245
EROSION CONTROL & DIVERSION
23. TYPE 'C' SILT FENCE INLCUDING MAINTENANCE & REMOVAL LF 525
24. SAND BAGS FOR FLOW DIVERSION, INCLUDING MAINTENANCE & REMOVAL LF 140
25. FLOW DIVERSION & FOUNDATION EXCAVATION WATER CONTROL BY CONTRACTOR MEANS LS 1
26. HAY BALES, INCLUDING MAINTENANCE & REMOVAL LF 100
27. BERMUDA SOD SF 550
28. STRAW/COCONUT MATTING SF 600
29. GABION EROSION SYSTEM - SCOURLOK LF 44
30. REINFORCED SLOPE STABILIZATION - ARMORMAX SY 42
30. TEMPORARY GRASSING, INCLUDING MULCH SF 650
31. PERMANENT GRASSING, INCLUDING MULCH SF 2,000
32. TYPE III RIP RAP TN 50
Demolition/Removal Subtotal =
New Struction - Contech Aluminum Box Culvert #51 Subtotal =
Paving & Concrete Flatwork Subtotal =
CITY OF GRIFFIN
GRIFFIN GOLF COURSE BRIDGE REPLACEMENTS
BID TABULATION
General Subtotal =
EXHIBIT "A"
Revised March 14, 2024
33. CONCRETE WASHOUT PER PLANS EA 2
MISCELLANEOUS
34. ONE WAY SIGNS INCLUDING INSTALLATION EA 3
35. SINGLE SWING GATE - 18' LONG EA 1
36. BARRIER REFLECTORS - SHUR-TITE 3" WHITE EA 14
37. 4-INCH WHITE STRIPING (PARKING SPACES) THERMOPLASTIC LF 34
38. ROAD BARRICADES FOR TRAFFIC CONTROL LF 146
39. ORANGE BARRIER FENCE - 4' HIGH LF 130
39. WING WALL TO EXISTING CONCRETE WALL DETAIL LS 1
40. WING WALL TO EXISTING STACKED CONCRETE WALL DETAIL LS 1
41. 36-INCH DIAMETER TREE REMOVAL AND DISPOSAL LS 1
42. TRENCH ROCK CY 10
Erosion Control & Diversion Subtotal =
TOTAL CONSTRUCTION
Miscellaneous Subtotal =
EXHIBIT "A"
BRIDGE B
GENERAL
1. PAYMENT & PERFORMANCE BONDS LS 1
2. GENERAL CONDITIONS LS 1
3. CONSTRUCTION STAKING BY REGSITERED SURVEYOR LS 1
4. AS-BUILT SURVEY BY REGISTERED SURVEYOR LS 1
DEMOLITION/REMOVAL
5. COMPLETE DEMOLITION OF EXISTING CONCRETE BRIDGE INCLUDING OFFSITE DISPOSAL LS 1
6. SAW CUT ASPHALT (VARIOUS DEPTHS) LF 79
7. REMOVAL OF ASHPALT PAVING COMPLETE INCLUDING OFFSITE DISPOSAL (VARIOUS THICKNESSES) SY 162
8. REMOVAL OF DEBRIS AND CONCRETE IN STREAM LS 1
9. REMOVAL OF EXISTING GATE & POSTS LS 1
10. REMOVAL OF CONCRETE FLUME NOTED ON DEMO PLAN LS 1
NEW STRUCTURE - CONTECH ALUMINUM BOX CULVERT #52
11. ALUMINUM BOX CULVERT ASSEMBLY & INSTALLATION INCLUDING ALUMINUM WING WALLS COMPLETE LS 1
12. ALUMINUM BOX CULVERT FOUNDATION SYSTEM COMPLETE PER PLANS LS 1
13. PREPARATION FOR INSTALLATION OF CONTECH STRUCTURE, WING WALL EMBEDMENT & TIE BACKS LS 1
14. #4 STONE FOR FOUNDATION BASE TN 35
15. G.A.B. IN PLACE FOR BACKFILL OF CULVERT & WINGWALLS TN 618
16. ASPHALT PAVING (6 : 2 : 1 1/2) SECTION) SY 162
17. GRADING COMPLETE (TOPSOIL, FINE GRADING, & REPLACEMENT OF EXISTING FILL EXCAVATED) LS 1
PAVING & CONCRETE FLATWORK
18. 8" REINFORCED CONCRETE BRIDGE SLAB INCLUDING REINFORCING PER DETAIL SF 540
19. 32" TALL CONCRETE BARRIER LF 56
20. CONCRETE CURB AT BASE OF BARRIER ON BRIDGE LF 56
21. CONCRETE FLUME LS 1
STORM DRAINAGE
22. 18" CLASS III RCP LF 14
23. 4' DIAMETER MANHOLE VF 7
24. 4' FLAT LID WITH SQUARE OPENING EA 1
25. 4X4 RAISED LID WITH PEDESTALS EA 1
30. CONCRETE FILL AT GABION EA 1
31. CONCRETE HEADWALL EA 1
EROSION CONTROL
32. TYPE 'C' SILT FENCE INLCUDING MAINTENANCE & REMOVAL LF 640
33. SAND BAGS FOR FLOW DIVERSION, INCLUDING MAINTENANCE & REMOVAL LF 140
CITY OF GRIFFIN
GRIFFIN GOLF COURSE BRIDGE REPLACEMENTS
BID TABULATION
General Subtotal =
Demolition/Removal Subtotal =
New Structure - Contech Aluminum Box Culvert #52 Subtotal =
Paving & Concrete Flatwork Subtotal =
Storm Drainage Subtotal =
EXHIBIT "A"
34. FLOW DIVERSION & FOUNDATION EXCAVATION WATER CONTROL BY CONTRACTOR MEANS LS 1
35. HAY BALES, INCLUDING MAINTENANCE & REMOVAL LF 100
36. BERMUDA SOD SF 600
37. STRAW/COCONUT MATTING SF 1,000
38. GABION EROSION SYSTEM - SCOURLOK LF 100
39. REINFORCED SLOPE STABILIZATION - ARMORMAX SY 56
40. TEMPORARY GRASSING, INCLUDING MULCH SF 500
41. ROAD BARRICADES FOR TRAFFIC CONTROL SF 2,000
42. TYPE III RIP RAP TN 50
43. CONCRETE WASHOUT PER PLANS EA 2
MISCELLANEOUS
1. TRENCH ROCK CY 10
44. STOP SIGN WITH POST POST COMPLETE EA 1
45. ONE WAY SIGNS INCLUDING INSTALLATION EA 2
46. 12-INCH WHITE STOP BAR - 12' IN LENGTH EA 1
47. DOUBLE SWING GATE - 10' LONG EA 2
48. BARRIER REFLECTORS - SHUR-TITE 3" WHITE EA 14
49. 4-INCH WHITE STRIPING (PARKING SPACES) THERMOPLASTIC LF 40
50. CONCRETE DUMPSTER PAD - 10'X10'X8" LS 1
51. ROAD BARRICADES FOR TRAFFIC CONTROL LF 100
52. ORANGE BARRIER FENCE - 4' HIGH LF 146
52. 45-INCH DIAMETER TREE REMOVAL AND DISPOSAL LS 1
53. TRENCH ROCK CY 10
TOTAL CONSTRUCTION FOR BRIDGE A & BRIDGE B
Erosion Control Subtotal =
Miscellaneous Subtotal =
TOTAL CONSTRUCTION FOR BRIDGE A
TOTAL CONSTRUCTION FOR BRIDGE B
TOTAL CONSTRUCTION
EXHIBIT "A"
GENERAL NOTES:
1. THIS SPECIFICATION COVERS THE MANUFACTURE AND INSTALLATION OF THE
ALUMINUM BOX CULVERT (ALBC) STRUCTURE AS DETAILED IN THE PLANS. ANY
INSTALLATION INFORMATION PROVIDED HEREIN SHALL BE REVIEWED AND APPROVED
BY THE ENGINEER. CHANGES AND DISCREPANCIES MUST BE FORWARDED TO THE
MANUFACTURER TO BE INCORPORATED IN A REVISED DRAWING SET.
2. THE ENGINEER SHALL VERIFY THAT THE PROPOSED STRUCTURE IS APPROPRIATE FOR
THE SITE CONDITIONS AND THE DESIGN PARAMETERS ARE CONSISTENT WITH THE
PROJECT REQUIREMENTS. ALL ASPECTS OF THE STRUCTURE DESIGN AND SITE
LAYOUT NOT EXPLICITLY INCLUDED IN THESE DRAWINGS SHALL BE PROVIDED OR
COORDINATED BY THE ENGINEER. THIS MAY INCLUDE BUT IS NOT LIMITED TO:
FOUNDATIONS, BACKFILL, END TREATMENTS, HYDRAULIC ANALYSIS AND SCOUR
ANALYSIS AS REQUIRED.
3. CONTECH PRODUCT DRAWINGS MAY NOT BE USED, REPRODUCED, COPIED, OR
ISSUED TO A THIRD PARTY WITHOUT THE PRIOR WRITTEN PERMISSION OF CONTECH
ENGINEERED SOLUTIONS.
4. ALL DIMENSIONS ARE TO THE INSIDE CREST OF THE CORRUGATION PROFILE UNLESS
NOTED OTHERWISE AND ARE SUBJECT TO MANUFACTURING TOLERANCES.
5. THE STRUCTURE GEOMETRY, DESIGN, AND MATERIALS AS SHOWN IN THESE
DRAWINGS ONLY APPLY TO THE ALBC, DESIGNED AND FABRICATED BY CONTECH
ENGINEERED SOLUTIONS (CONTECH). ALTERNATIVE SYSTEMS SHALL BE FULLY
DESIGNED AND APPROVED PRIOR TO BIDDING, WITH SEALED DRAWINGS AND
CALCULATIONS PROVIDED TO DEMONSTRATE COMPLIANCE WITH THE SAME
GEOMETRY, DESIGN, AND MATERIAL REQUIREMENTS AS SHOWN HEREIN.
6. CIRCUMFERENTIAL PLATE LENGTHS ARE IN TERMS OF N = 9.625 INCHES.
7. FOR WATER CONVEYANCE APPLICATIONS THE STRUCTURE MUST MEET HYDRAULIC
REQUIREMENTS OF THE SITE AS DETERMINED BY THE ENGINEER. SHEET PILING,
INLET AND OUTLET APRONS, CUTOFF WALLS, RIP RAP, AND/OR OTHER MEASURES
SHALL BE INSTALLED AS NECESSARY TO PREVENT LOSS OF ENGINEERED BACKFILL
AND/OR FOUNDATION SOILS DUE TO SCOUR. THE EXTENT, SIZE, AND LOCATION OF
SCOUR PROTECTION SHALL BE DETERMINED BY THE ENGINEER.
8. PERIMETER DRAINAGE, SURFACE DRAINAGE, AND GRADING AROUND THE STRUCTURE
SHALL BE DESIGNED, SPECIFIED, SUPPLIED, AND INSTALLED BY OTHERS.
DESIGN PARAMETERS
1. DESIGN BY CONTECH ENGINEERED SOLUTIONS IS BASED ON THE FOLLOWING DESIGN
CRITERIA:
VEHICLE LIVE LOAD:HL-93
MINIMUM COVER: 2.5
MAXIMUM COVER: 4.0
UNIT WEIGHT OF ENGINEERED BACKFILL = 120 LBS/FT³.
2. ENGINEERED BACKFILL MATERIAL SHALL COMPLY WITH THE ENGINEERED BACKFILL
MATERIAL REQUIREMENTS SHOWN IN THESE DRAWINGS.
3. DESIGN COVER AND LATERAL EXTENT OF ENGINEERED BACKFILL ZONE SHALL BE AS
SHOWN IN THESE DRAWINGS AND REQUIRED BY THE DESIGN STANDARDS
REFERENCED IN THESE NOTES.
4. REFERENCE AASHTO LRFD SECTION 12.6.1 FOR SEISMIC DESIGN CONSIDERATIONS.
5. STRUCTURE DESIGN BASED ON SITE SOIL INFORMATION PROVIDED IN CONTRACT
DOCUMENTS. IF UNEXPECTED SITE SOIL CONDITIONS ARE ENCOUNTERED, CONTECH
MUST BE NOTIFIED TO DETERMINE IF DESIGN CHANGES ARE NEEDED.
6. TEMPORARY CONSTRUCTION VEHICLE LOADING HEAVIER THAN THE DESIGN VEHICLE
LIVE LOAD SHALL NOT BE PERMITTED TO CROSS OVER THE STRUCTURE WITHOUT THE
APPROVAL OF CONTECH. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY
CONTECH OF THE SIZE, TYPE AND WEIGHT OF ANY CONSTRUCTION VEHICLES
INTENDED TO CROSS OVER THE STRUCTURE.
7. STANDARD HIGHWAY LOADS THAT MEET PERMISSIBLE DESIGN LOAD LIMITS FOR AN
ALBC ARE NOT ALLOWED ON THE STRUCTURE UNTIL IT IS BACKFILLED COMPLETELY
AND PAVEMENT IS IN PLACE.
8. IT IS RECOMMENDED THAT UNPAVED ROADS INCORPORATE AT LEAST 6" MORE THAN
MINIMUM ALLOWABLE COVER DEPTH TO ALLOW FOR RUTTING.
HAUNCH REINFORCING RIB
RIB SPLICE CROWN REINFORCING RIB
ALBC - END VIEW
INVERT CORNERS OF HAUNCH
PLATES PAINTED RED
20'-6"
KF
JEM
CHECKED:
DRAWN:
DESIGNED:
APPROVED:
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
U M
B
O X
C
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
W G
P
M
SHEET NO.:
OF
2/28/2024
DATE:PROJECT No.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
REVISION DESCRIPTIONDATEMARK BY
700 Tech Drive, Winchester, KY 40391
859-744-3339 859-744-9665 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
1. DESIGN AND MANUFACTURING STANDARDS
1.1 STANDARDS - ALL STANDARDS REFER TO THE CURRENT ASTM / AASHTO EDITION UNLESS
OTHERWISE NOTED.
1.2 AASHTO M219 - STANDARD SPECIFICATION FOR CORRUGATED ALUMINUM ALLOY STRUCTURAL
PLATE FOR FIELD-BOLTED PIPE, PIPE-ARCHES AND ARCHES
1.3 AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SECTION 12.
1.4 AASHTO LRFD BRIDGE CONSTRUCTION SPECIFICATIONS - SECTION 26.
1.5 ASTM B864 - STANDARD SPECIFICATION FOR CORRUGATED ALUMINUM BOX CULVERTS.
2. DEFINITIONS
2.1 ENGINEER - IN THESE NOTES THE WORD “ENGINEER” SHALL MEAN THE ENGINEER OF RECORD OR
OWNER'S DESIGNATED ENGINEERING REPRESENTATIVE.
2.2 MANUFACTURER - IN THESE NOTES THE WORD “MANUFACTURER” SHALL MEAN THE
MANUFACTURER OF THE ALBC, CONTECH ENGINEERED SOLUTIONS @ PHONE 800/338-1122.
2.3 CONTRACTOR - IN THESE NOTES THE WORD “CONTRACTOR” SHALL MEAN THE FIRM OR
CORPORATION UNDERTAKING THE EXECUTION OF ANY INSTALLATION WORK UNDER THE TERMS OF
THESE SPECIFICATIONS.
3. ALUMINUM BOX CULVERT (ALBC) STRUCTURE ASSEMBLY
3.1 ASSEMBLY OF THE ALBC SHALL BE IN ACCORDANCE WITH SECTION 26 OF AASHTO LRFD
CONSTRUCTION SPECIFICATIONS (LATEST EDITION, WITH INTERIMS) AND ANY SUPPLEMENTAL
RECOMMENDATIONS PROVIDED BY THE MANUFACTURER.
3.2 ALL PLATES AND ACCESSORIES SHALL BE UNLOADED AND HANDLED WITH REASONABLE CARE.
PLATES SHALL NOT BE ROLLED OR DRAGGED OVER GRAVEL ROCK AND SHALL BE PREVENTED FROM
STRIKING ROCK OR OTHER HARD OBJECTS DURING PLACEMENT IN TRENCH OR ON BEDDING.
3.3 FOR STRUCTURES SET ON CONCRETE FOOTINGS, PLATE ASSEMBLY CAN BEGIN AFTER PLACEMENT
OF STRUCTURE FOOTINGS HAS BEEN APPROVED BY THE ENGINEER. VERIFICATION OF PROPER
SPACING, ALIGNMENT, AND ORIENTATION OF THE FOUNDATIONS IS STRONGLY RECOMMENDED
PRIOR TO BEGINNING PLATE ASSEMBLY. ANY MODIFICATIONS TO THE FOUNDATIONS SHALL BE
MADE PRIOR TO BEGINNING PLATE ASSEMBLY.
3.4 WHEN A METAL FOUNDATION IS USED, THE SOIL BEDDING REQUIRES A MINIMUM OF 6 INCHES OF
LOOSE GRANULAR MATERIAL WITH A MAXIMUM PARTICLE SIZE OF ONE HALF THE CORRUGATION
DEPTH. THE PROPER WIDTH OF THE BEDDING MATERIAL REQUIRED SHALL CONFORM TO THE
PROJECT PLANS AND SPECIFICATIONS.
BEDDING PREPARATION SHOULD BE APPROVED BY THE ENGINEER PRIOR TO ASSEMBLY. THE BED
SHOULD BE CONSTRUCTED TO UNIFORM LINE AND GRADE. IT SHOULD BE FREE OF ROCK
FORMATIONS, PROTRUDING STONES, FROZEN LUMPS, ROOTS AND OTHER FOREIGN MATTER.
3.5 THE SPAN AND RISE OF THE STRUCTURE SHOULD BE CHECKED FREQUENTLY DURING THE EARLY
STAGES OF ASSEMBLY TO VERIFY THAT ASSEMBLY TOLERANCES ARE BEING ACHIEVED AND TO
ALLOW FOR ADJUSTMENTS TO PROCEDURES, IF NECESSARY, BEFORE ASSEMBLY IS COMPLETE.
3.6 CUT PLATES FOR SKEWED ENDS SHOULD BE ATTACHED AFTER THE MAIN BARREL OF A STRUCTURE
HAS BEEN ASSEMBLED. WHEN CAST-IN-PLACE CONCRETE COLLARS OR HEADWALLS ARE TO BE
CONSTRUCTED, THE CONTRACTOR MUST ALLOW FOR FORMWORK TO BE ERECTED ON THE END OF
THE STRUCTURE. FORMING AGAINST A SKEWED CORRUGATION PROFILE IS COMPLEX AND SHOULD
BE ACCOUNTED FOR BY THE FORMING CONTRACTOR WHEN PLANNING PROCEDURES AND
METHODS FOR FORMWORK CONSTRUCTION. IN SOME CASES, FIELD TRIMMING OF THE
STRUCTURE MAY BE NECESSARY. SPECIAL BRACING AND/OR SCAFFOLDING (DESIGN BY OTHERS) IS REQUIRED TO SUPPORT SKEWED ENDS UNTIL ADEQUATE COMPRESSIVE STRENGTH IS ACHIEVED AS
REQUIRED BY THE COLLAR/HEADWALL DESIGNER.
3.7 NUTS SHALL BE PLACED WITH THE ROUNDED FACE IN CONTACT WITH THE PLATES UNLESS NOTED OTHERWISE. NUTS CAN BE ON EITHER THE INSIDE OR OUTSIDE OF THE STRUCTURE TO FACILITATE
ASSEMBLY.
3.8 BOLTS AND NUTS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-307 and/or ASTM A-449.
RECOMMENDED TORQUE RANGE ON THE BOLTS IS 100 TO 150 FT-LBS.
3.9 INSIDE SPAN AND RISE OF THE ASSEMBLED STRUCTURE AFTER BOLTING SHALL BE WITHIN 2% OF
THE PLAN DIMENSIONS. THE STRUCTURE LENGTH SHALL BE WITHIN 1%.
4. ENGINEERED BACKFILL ENVELOPE
4.1 ENGINEERED BACKFILL MATERIAL SHALL BE PLACED WITHIN THE ENGINEERED BACKFILL ENVELOPE
TO THE MINIMUM WIDTH AND WITHIN THE COVER LIMITS SHOWN ON THESE DRAWINGS. THE
ENGINEERED BACKFILL ENVELOPE SHALL NOT BE ALTERED WITHOUT WRITTEN APPROVAL FROM
CONTECH.
4.2. IN-SITU SOILS BELOW AND ADJACENT TO THE ENGINEERED BACKFILL ENVELOPE SHALL PROVIDE A
FIRM SURFACE AGAINST WHICH TO COMPACT THE ENGINEERED BACKFILL MATERIAL. THE
GEOTECHNICAL ENGINEER SHALL EVALUATE THE IN-SITU SOILS AND DETERMINE THE TYPE AND DEGREE OF ANY SOIL IMPROVEMENTS REQUIRED. THESE MAY INCLUDE BENCHING OR SLOPING OF THE SIDE SOILS. BACKFILL PLACEMENT MAY NOT BEGIN UNTIL THE GEOTECHNICAL ENGINEER HAS
APPROVED THE IN-SITU SOILS AND ANY REQUIRED IMPROVEMENTS.
4.3. A DRAINED CONDITION WAS ASSUMED FOR THE ENGINEERED BACKFILL ENVELOPE. DESIGN AND
SUPPLY OF A SUBSURFACE DRAINAGE SYSTEM (IF NEEDED) SHALL BE PROVIDED BY OTHERS.
4.4. IF REQUIRED BY THE GEOTECHNICAL ENGINEER, A GEOTEXTILE OR GRADED SOIL FILTER MAY BE USED BETWEEN THE ENGINEERED BACKFILL AND IN-SITU SOIL TO PREVENT MIGRATION OF FINES
AND POSSIBLE INTERNAL EROSION OF THE SOIL.
5. ENGINEERED BACKFILL MATERIAL REQUIREMENTS
5.1 THE DESIGN OF ALBC STRUCTURES RELIES ON COMPACTED SOIL PROPERTIES PROVIDED BY THE
ENGINEERED BACKFILL MATERIALS. THE CORRECT SELECTION AND PLACEMENT OF COMPACTED
ENGINEERED BACKFILL MATERIAL IS CRITICAL TO THE PERFORMANCE OF ALBC STRUCTURES.
5.2 THE ENGINEERED BACKFILL MATERIAL SHALL NOT BE ADVERSELY AFFECTED BY WETTING, DRYING, SATURATION, FREEZE/THAW, VIBRATIONS, OR FLOWING WATER.
5.3 BACKFILL MATERIALS SHALL CONFORM TO PROPERTIES REFERENCED IN THE PROJECT
SPECIFICATIONS OR THE PROPERTIES DESCRIBED HEREIN, WHICHEVER IS MORE STRINGENT.
5.4 ALBC NUMBERS 1 THROUGH 87 SHALL BE BACKFILLED USING CLEAN WELL GRADED GRANULAR MATERIAL THAT MEETS THE REQUIREMENTS FOR SOIL CLASSIFICATIONS A-1, A-2-4, A-2-5, OR A-3
MODIFIED PER AASHTO M-145.
A-3 MATERIAL MAY NOT CONTAIN FINE BEACH SANDS, WINDBLOWN SANDS, STREAM DEPOSITED
SAND, ETC. EXHIBITING FINE, ROUNDED PARTICLES.
ALBC NUMBERS 88 THROUGH 143 SHALL BE BACKFILLED USING CLEAN WELL GRADED GRANULAR
MATERIAL THAT MEETS THE REQUIREMENTS FOR SOIL CLASSIFICATIONS A-1, A-2-4 OR A-2-5 PER
AASHTO M-145.
REFER TO BACKFILL DETAILS FOR SOIL CLASSIFICATION TABLE. OPEN GRADED OR GAP GRADED MATERIALS ARE NOT PREFERRED. THE BACKFILL MATERIAL SHOULD BE FREE OF FROZEN LUMPS, FOREIGN MATERIAL OR ORGANIC DECOMPOSABLE MATERIALS. WHEN USING A-2 MATERIALS, MOISTURE CONTENT MUST BE BETWEEN -3% AND +2% OPTIMUM AS DEFINED BY AASHTO T 180.
5.5 GRAIN SIZE DISTRIBUTION (GRADATION) OF THE ENGINEERED BACKFILL MATERIAL SHALL SATISFY:
Cu GREATER THAN OR EQUAL TO 3 AND Cc BETWEEN 0.7 AND 3, WHERE Cu = COEFFICIENT OF UNIFORMITY = D60/D10 AND Cc = COEFFICIENT OF CURVATURE = (D30)²/(D60XD10). DXX IS THE PARTICLE SIZE CORRESPONDING TO XX% FINER ON THE CUMULATIVE PARTICLE SIZE DISTRIBUTION
CURVE (ASTM D2487).
Cu REQUIREMENTS ARE WAIVED FOR CRUSHER RUN SCREENED AGGREGATES. Cc REQUIREMENTS
ARE WAIVED FOR BACKFILL MATERIAL CONTAINING MORE THAN 60% GRAVEL (> #4 SIEVE).
5.6 ABRASION LOSS SHALL NOT EXCEED 45% AS DETERMINED BY THE LOS ANGELES ABRASION TEST
(ASTM C131).
5.7 HUMIC (DECAYING) ORGANIC MATTER SHALL NOT EXCEED 1.0% (DRY WEIGHT BASIS).
5.8 ELECTROCHEMICAL REQUIREMENTS FOR SOIL AND WATER IN CONTACT WITH BOTH THE INSIDE
AND OUTSIDE OF THE ALBC STRUCTURE ARE AS FOLLOWS:
- PH = 4 TO 9
- RESISTIVITY > 500 OHM-CM
5.9 IF THE ELECTROCHEMICAL PROPERTIES OF THE BACKFILL OR WATER FALL OUTSIDE OF THE
RECOMMENDED RANGE, A SECONDARY PROTECTION SYSTEM MAY BE NEEDED TO ACHIEVE THE
DESIGN SERVICE LIFE. SECONDARY PROTECTION SYSTEMS (IF REQUIRED) SHALL BE DESIGNED AND
PROVIDED BY OTHERS.
5.10 THE SELECTION AND EVALUATION OF PROPOSED ENGINEERED BACKFILL MATERIAL IS THE RESPONSIBILITY OF THE CONTRACTOR. THE PROPOSED ENGINEERED BACKFILL MATERIAL SHALL
MEET OR EXCEED THE REQUIREMENTS OF THESE SPECIFICATIONS.
6. ENGINEERED BACKFILL PLACEMENT PROCEDURE
6.1 CONTECH RECOMMENDS THAT A PRECONSTRUCTION CONFERENCE IS HELD PRIOR TO
COMMENCEMENT OF WORK TO REVIEW AND DISCUSS THE RECOMMENDED PROCEDURES FOR
BACKFILLING, AND STRUCTURE SHAPE MEASUREMENTS. ANY CONTRACTOR WITH RESPONSIBILITY
FOR BACKFILLING OR CONSTRUCTION OF END TREATMENTS MUST BE REPRESENTED AT THIS
MEETING. IT IS RECOMMENDED THAT THE ENGINEER AND ANY THIRD PARTY INVOLVED IN
COMPACTION TESTING OR OTHER QUALITY CONTROL MEASURES ALSO ATTEND.
6.2 ANY IMPROVEMENT OF THE SUBGRADE AND EMBANKMENT SOILS REQUIRED BY THE
GEOTECHNICAL ENGINEER SHALL BE COMPLETED AND APPROVED PRIOR TO BEGINNING
PLACEMENT OF ENGINEERED BACKFILL MATERIAL.
6.3 THE ENGINEERED BACKFILL MATERIAL SHALL BE PLACED UNIFORMLY ON BOTH SIDES OF THE
STRUCTURE IN LAYERS OF 8 INCHES OR LESS (BEFORE COMPACTION).
6.4 BACKFILL SHALL BE COMPACTED TO THE MINIMUM DENSITY INDICATED IN THESE DRAWINGS.
DEPENDING ON THE COMPACTION EQUIPMENT AND ENGINEERED BACKFILL MATERIAL USED, IT
MAY BE NECESSARY TO DECREASE THE LIFT THICKNESS AND/OR MOISTURE CONDITION THE LOOSE
SOIL TO ACHIEVE THE SPECIFIED MINIMUM LEVEL OF COMPACTION.
6.5 IF THE ENGINEERED BACKFILL MATERIAL DOES NOT PRODUCE A PROCTOR CURVE AND/OR IS NOT CONDUCIVE TO TRADITIONAL FIELD-TESTING METHODS, QUALITATIVE METHODS OF EVALUATING
COMPACTION MAY BE USED. SUCH METHODS SHALL BE EVALUATED AND APPROVED BY THE
GEOTECHNICAL ENGINEER AND A COPY OF THE METHOD BE PROVIDED TO THE DESIGNER.
6.6 THE DIFFERENCE IN BACKFILL LEVELS ON THE TWO SIDES OF THE STRUCTURE AT ANY TRANSVERSE
SECTION SHALL NOT EXCEED 24 INCHES WITHOUT PRIOR APPROVAL FROM CONTECH.
6.7 CONSTRUCTION EQUIPMENT USED WITHIN 5 FEET LATERALLY OF THE WIDEST PART OF THE STRUCTURE, UP TO THE MINIMUM DESIGN COVER HEIGHT ABOVE THE STRUCTURE, SHALL HAVE A STATIC MASS OF 10 TONS OR LESS. IT MAY BE POSSIBLE TO USE HEAVIER EQUIPMENT IF IT CAN BE
DEMONSTRATED THAT THE STRUCTURE SHAPE IS NOT ADVERSELY AFFECTED. ENGINEERED
BACKFILL MATERIAL PLACED WITHIN 1 FOOT LATERALLY OF THE WIDEST PART OF THE STRUCTURE
SHALL BE COMPACTED USING HAND OPERATED EQUIPMENT UNTIL THE MINIMUM COVER HEIGHT
IS REACHED. OVER-COMPACTION OF ENGINEERED BACKFILL IN THIS ZONE SHOULD BE AVOIDED, AS THIS CAN CONTRIBUTE TO EXCESSIVE DEFLECTION OF SOME STRUCTURES. AREAS CLOSEST TO THE
STRUCTURE SHALL BE COMPACTED RUNNING PARALLEL TO THE LENGTH OF THE STRUCTURE.
6.8 ONCE THE BACKFILL ELEVATION REACHES THE MIDDLE OF THE HAUNCH CURVE (DEPENDING ON
RELATIVE MOVEMENT DURING THE BACKFILL PROCESS), PLACE AND COMPACT ENGINEERED
BACKFILL MATERIAL IN RADIAL LIFTS OVER THE TOP OF THE STRUCTURE USING EQUIPMENT AS DESCRIBED ABOVE. THE FIRST RADIAL LIFT SHOULD BE THICKER AND PROVIDE A MINIMUM 12
INCHES OF COVER BETWEEN THE STRUCTURE AND COMPACTION EQUIPMENT. EQUIPMENT
SHOULD RUN PERPENDICULAR TO THE LONGITUDINAL AXIS OF THE STRUCTURE. NO EQUIPMENT
SHALL BE ALLOWED OVER THE STRUCTURE THAT WOULD EXCEED THE DESIGN LOAD AT THE
MINIMUM DESIGN HEIGHT OF COVER. NO CONSTRUCTION EQUIPMENT SHALL BE ALLOWED TO
PARK ON TOP OF A PARTIALLY BACKFILLED STRUCTURE.
6.9 AT NO TIME SHALL THE ENGINEERED BACKFILL MATERIAL BE DUMPED OR PUSHED AGAINST THE STRUCTURE WALL(S) SO AS TO CHANGE THE SHAPE OR ALIGNMENT OF THE STRUCTURE. MATERIAL
SHALL NOT BE DUMPED ON TOP OF THE STRUCTURE AT ANY TIME. TRUCKS MAY UNLOAD IN
ROUGH LAYERS NO CLOSER THAN 5 FEET FROM THE WIDEST PART OF THE STRUCTURE.
6.10 THE STRUCTURE SHALL BE CHECKED PERIODICALLY DURING BACKFILLING TO ENSURE THE FINAL
SHAPE OF THE STRUCTURE MEETS DESIGN REQUIREMENTS AND IS CONSISTENT WITH THE
ASSEMBLY TOLERANCES AS STATED IN THESE NOTES. IF DEFLECTION OF THE STRUCTURE IS
GREATER THAN EXPECTED, BACKFILLING SHALL BE HALTED AND BACKFILL PLACEMENT AND
COMPACTION PROCEDURES MODIFIED TO CORRECT THE STRUCTURE SHAPE. IT MAY BE
NECESSARY TO REMOVE SOME OF THE BACKFILL TO CORRECT EXCESSIVE DEFLECTION.
7. CONSTRUCTION OBSERVATIONS AND TESTING
7.1. OBSERVATION AND TESTING SHALL BE PERFORMED DURING CONSTRUCTION TO VERIFY
COMPLIANCE WITH THESE DRAWINGS, APPLICABLE PROJECT DOCUMENTS, AND STANDARDS
REFERENCED IN THESE NOTES.
7.2. THE CONTRACTOR IS RESPONSIBLE FOR QUALITY CONTROL PROCEDURES, VERIFICATION
MEASUREMENTS, ADEQUATE SUPERVISION, PROGRESS TESTING, EVALUATION OF PROPOSED
ENGINEERED BACKFILL MATERIALS, AND/OR OTHER MEASURES AS NEEDED TO ENSURE THAT THE
COMPLETED PROJECT COMPLIES WITH THESE DRAWINGS AND NOTES.
7.3. THE PROJECT OWNER (OR THEIR DESIGNATED REPRESENTATIVE) IS RESPONSIBLE FOR PROJECT
OVERSIGHT AND FINAL ACCEPTANCE OF THE CONSTRUCTED STRUCTURE. THE OWNER MAY
ACCEPT THE CONTRACTOR'S QUALITY CONTROL PROGRAM OR ADOPT AN INDEPENDENT QUALITY
ASSURANCE PROGRAM TO VERIFY COMPLIANCE.
7.4. OBSERVATIONS AND TESTING PRIOR TO STRUCTURE ASSEMBLY & BACKFILL SHALL INCLUDE BUT
NOT BE LIMITED TO:
- EVALUATION OF FOUNDATION SOILS BELOW FOOTINGS AND THE ENGINEERED BACKFILL
ENVELOPE
- VERIFICATION OF PROPER ALIGNMENT, DIMENSIONS, AND PLACEMENT OF FOUNDATIONS
- VERIFICATION OF PROPER SHAPING, PLACEMENT, AND PREPARATION OF BEDDING SOILS
(STRUCTURES WITH INVERTS)
- VERIFICATION OF PROPER PREPARATION OF EMBANKMENT SOILS ADJACENT TO THE ENGINEERED
BACKFILL ENVELOPE
- EVALUATION AND APPROVAL OF ENGINEERED BACKFILL MATERIALS
- VERIFICATION OF PROPER PLACEMENT OF GEOTEXTILES (WHEN REQUIRED)
7.5 OBSERVATIONS AND TESTING DURING ASSEMBLY & BACKFILLING SHALL INCLUDE BUT NOT BE
LIMITED TO:
- STRUCTURE ALIGNMENT
- PLATE TIGHTNESS OBSERVATIONS
- BOLT TORQUE MEASUREMENTS
- INITIAL STRUCTURE SHAPE MEASUREMENTS (PRIOR TO STARTING BACKFILLING)
- PERIODIC STRUCTURE SHAPE MEASUREMENTS (DURING BACKFILLING)
- ENGINEERED BACKFILL MATERIAL SAMPLING AND TESTING
- OBSERVATIONS OF PROPER FILL PLACEMENT AND COMPACTION PROCEDURES.
7.6 CONTECH MAY REQUIRE ADDITIONAL OBSERVATIONS AND/OR TESTING WHICH MAY INCLUDE, BUT
NOT BE LIMITED TO, FULL TIME SHAPE MONITORING, ADDITIONAL SOIL TESTING, AND SITE
EVALUATIONS DEPENDING ON THE STRUCTURE GEOMETRY, DESIGN, AND/OR OTHER PROJECT
SPECIFIC FACTORS.
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
3/4" DIA. x 10'-0"
ANCHOR ROD (TYPICAL)
FLOW
PLAN VIEW
S
P A
N
OVERALL LENGTH = 18'-3"
ALUMINUM BOX CULVERT
#51: 20'-6" SPAN x 7'-3" RISE
H
E A
D W
A L L
H
E A
D W
A L L
4'-9"
4'-6"
DEADMAN ANCHOR
ALUMINUM STRUCTURAL PLATE 0.150"
(1'-8" x 2' 4-3/4" (TYPICAL)
3/4" DIA. x 12'-6" ANCHOR ROD (TYPICAL)
9'-3"
4'-9"
4'-6"
DEADMAN ANCHOR
ALUMINUM STRUCTURAL PLATE 0.150"
(1'-8" x 2' 4-3/4" (TYPICAL)
3/4" DIA. x 12'-6" ANCHOR ROD (TYPICAL)
9'-3"
4'-9"
4'-6"
DEADMAN ANCHOR
ALUMINUM STRUCTURAL PLATE 0.150"
(1'-8" x 2' 4-3/4" (TYPICAL)
3/4" DIA. x 12'-6" ANCHOR ROD (TYPICAL)
9'-3"
4'-9"
DEADMAN ANCHOR
ALUMINUM STRUCTURAL PLATE 0.150"
(1'-8" x 2' 4-3/4" (TYPICAL)
3/4" DIA. x 12'-6" ANCHOR ROD (TYPICAL)
NOTE:
SHADED AREA REPRESENTS CRITICAL BACKFILL ZONES.
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
K
E Y
W A
Y
4'-6"
C.I.P. CONCRETE
(10) - #5 BARS CONTINUOUS
TOP & BOTTOM
#5 BENT BARS @ 18" O.C.
INSIDE FACE
OF ALBC
2'-6" 8" 1'-4"
T Y
P
2'-11" 1'-7"
20'-6" SPAN
4'-6"
2'-11" 1'-7"
R I S
E
ALUMINUM BOX CULVERT
ALBC #51
20'-6" SPAN X 7'-3" RISE
4'-6"
2'-11"1'-7"
17'-4" CLEAR SPAN
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
FOOTING DETAIL
CROSS SECTION
FOUNDATION NOTES:
1. THE ENGINEER SHALL VERIFY THAT THE PROPOSED FOUNDATION IS APPROPRIATE FOR THE
SITE CONDITIONS AND THE DESIGN PARAMETERS ARE CONSISTENT WITH THE PROJECT
REQUIREMENTS. THE FOUNDATION DESIGN CONSIDERS STRUCTURAL REQUIREMENTS OF THE
FOUNDATION ONLY. HYDRAULIC ANALYSIS AND SCOUR ANALYSIS, AS REQUIRED, SHALL BE
PERFORMED OR COORDINATED BY THE ENGINEER.
2. PRIOR TO CONSTRUCTION, CONTRACTOR MUST VERIFY ALL ELEVATIONS SHOWN WITH THE
ENGINEER.
3. FOUNDATION DESIGN IS BASED ON SITE SOIL INFORMATION PROVIDED TO CONTECH AND
DESCRIBED IN THE DESIGN PARAMETERS BELOW. FOUNDATION BEARING SOILS, INCLUDING
ANY SOIL IMPROVEMENTS REQUIRED, SHALL BE EVALUATED AND APPROVED BY OTHERS
PRIOR TO FOUNDATION CONSTRUCTION. IF UNEXPECTED SOIL CONDITIONS ARE
ENCOUNTERED, OR THE BEARING REQUIREMENTS CANNOT BE ACHIEVED, CONTECH MUST BE
NOTIFIED TO DETERMINE IF FOOTING DESIGN CHANGES ARE NEEDED.
4. REINFORCED CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE AASHTO LRFD
BRIDGE CONSTRUCTION SPECIFICATIONS, SECTION 8, REINFORCED CONCRETE, FOR CLASS A
CONCRETE HAVING A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI.
5. REINFORCING STEEL FOR FOUNDATIONS SHALL CONFORM TO ASTM A615, GRADE 60 (Fy=60 ksi).
6. KEYWAY TO BE FILLED WITH NON-METALLIC, NON-SHRINK GROUT, WITH A MINIMUM 4,000 PSI
COMPRESSIVE STRENGTH (ASTM C1107). GROUT AND SHIMMING MATERIAL SHOULD NOT
CONTAIN ANY CORROSION-PROMOTING AGENTS.
DESIGN PARAMETERS:
DESIGN LIVE LOAD: HL-93
DESIGN MAXIMUM FILL HEIGHT: 4'
DESIGN METHOD: LOAD FACTOR DESIGN PER AASHTO SPECIFICATION
DESIGN MINIMUM NET ALLOWABLE BEARING CAPACITY: 3,000 PSF*
*BEARING CAPACITY PROVIDED IN GEOTECHNICAL REPORT PREPARED BY ATLAS TECHNICAL
CONSULTANTS, LLC DATED APRIL 26, 2023.
PLATES ONLY - (REINFORCING RIBS NOT SHOWN FOR CLARITY)
MARK CORNERS RED
MARK CORNERS RED
LIP (1
")LIP (1
CENTERLINE LENGTH = 18'-0"
OVERALL LENGTH = 18'-3"
FLOW
12N PLATE
.125 THK.
12N PLATE
.125 THK.
12N PLATE
.125 THK.
A
A
A
A
A
A
A
A
CROWN
CENTERLINE
ALBC - DEVELOPED PLAN (OUTSIDE VIEW)
20'-6" SPAN x 7'-3" RISE
B B B
1 2
PLATE LAPPING DETAIL
3 PLATE STRUCTURE
NOTE:
BEGIN SHELL ASSEMBLY AT INLET END. SEE
ASSEMBLY GUIDE INCLUDED WITH THE MATERIAL
SHIPMENT FOR FURTHER INSTRUCTIONS.
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
LIP (1
")LIP (1
CENTERLINE LENGTH = 18'-0"
OVERALL LENGTH = 18'-3"
FLOW
HR1 - 2 PCS. x 86.0" LG.
TYPE IV HAUNCH LOCATE WHERE SHOWN
CR3 - 2 PCS. x 144.5" LG.
TYPE IV CROWN LOCATE WHERE SHOWN
HR4 - 11 PCS. x 95.5" LG.
TYPE VI HAUNCH @18" LOCATE WHERE SHOWN
CR6 - 11 PCS. x 144.5" LG.
TYPE VI CROWN @18" LOCATE WHERE SHOWN
HR1
CR3
RIB SPLICE
(22 REQD)
12N PLATE
.125 THK.
12N PLATE
.125 THK.
12N PLATE
.125 THK.
A
A
A
A
A
A
A
A
CROWN
CENTERLINE
ALBC - DEVELOPED PLAN (OUTSIDE VIEW)
20'-6" SPAN x 7'-3" RISE
B B B
REFER TO BOLT LENGTH
USAGE DETAIL - SHEET 7
1 2
FR7 - 2 PCS. x 17" LG.
TYPE IV FILLER LOCATE WHERE SHOWN
FR7
HR2 - 2 PCS. x 86.0" LG.
TYPE IV HAUNCH LOCATE WHERE SHOWN
HR5 - 11 PCS. x 95.5" LG.
TYPE VI HAUNCH @18" LOCATE WHERE SHOWN
FR8 - 2 PCS. x 17" LG.
TYPE IV FILLER LOCATE WHERE SHOWN
HR2
FR8
RIB SPLICE
TYPE VI RIB
TYPE IV RIB
NOTES:
1. PLATE ONLY LAPS AT CORRUGATION VALLEYS NOT SHOWN FOR CLARITY.
2. REFER TO SHEET 7 FOR ADDITIONAL DETAIL.
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
NOTES:
1. FOR PROPER BOLT SIZE USAGE, REFER TO THE FOLLOWING:
2 PLATE 3 PLATE
0.125" THK. PLATE 1 1/4" 1 1/4"
PLATE ONLY
1 PLATE 2 PLATE
0.125" THK. PLATE 1 1/4" 1 1/2"
PLATE W/ TYPE IV REINFORCING RIB
1 PLATE 2 PLATE 3 PLATE
0.125" THK. PLATE 1 1/2" 2" 2"
PLATE W/ TYPE VI REINFORCING RIB
A
B
1 PLATE W/ TYPE IV RIB
" BOLTS
USE 1
" BOLTS
@RIB SPLICES
1 PLATE W/ TYPE VI RIB
" BOLTS
BOLT LENGTH USAGE DETAIL
2 PLATE W/ TYPE VI RIB
2" BOLTS
2 PLATE W/ TYPE VI RIB
2" BOLTS
3 PLATE W/ TYPE VI RIB
2" BOLTS
2 PLATE LAP - (NO RIB)
" BOLTS
1 PLATE W/ TYPE VI RIB
" BOLTS
2 PLATE W/ TYPE IV RIB
" BOLTS
3 PLATE LAP - (NO RIB)
" BOLTS
1'-4
RIB SPLICE
RIB SPLICE
TYPE VI
CROWN RIB
" x 1
" BOLT
" NUT
RIB SPLICE
ATTACHMENT TO TYPE VI RIB
TYPE VI
CROWN RIB
TYPE VI
HAUNCH RIB
RIB SPLICE
NOTE:
THE ORIENTATION OF THE RIBS IS NOT CRITICAL,
BUT SHOULD BE KEPT CONSISTENT ALONG THE
LENGTH OF THE STRUCTURE.
RIB SPLICE
ISOMETRIC VIEW
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
1. WALL PANEL NUMBERS ARE MARKED ON THE SOIL SIDE.
2. BOLT HEADWALL TO REINFORCING RIB AT END OF STRUCTURE.
3. SEE SHEETS 10-14 FOR REFERENCED SECTIONS AND ADDITIONAL DETAILS.
4. ALL 2'-3" DIMENSIONS ARE RELATIVE TO SECTION B-B.
5. ALL 4 1/2" DIMENSIONS ARE RELATIVE TO SECTION F-F.
6. ○ DENOTES BOLTS CONNECTION
7. ● DENOTES ANCHOR ROD CONNECTION
ALBC - INLET EXPANDED END VIEW
SEE DETAIL M
SEE DETAIL L
24'-0"
BASEWALL WIDTH
90° HORIZONTAL
19° VERTICAL
ELBOW CAP MK. EC1
2'-3"
4'-9"
CORNER
PANEL
WALE BEAM
x 5'-2" LG.
HW CAP MK HC2
x 5'-5" LG.
4'-6"
END
PANEL
4'-6"
CENTER
PANEL
1'-6"
CENTER
PANEL
4'-6"
CENTER
PANEL
4'-6"
CENTER
PANEL
4'-6"
END
PANEL
HW CAP MK HC1
24'-3" LG.
80° HORIZONTAL
15° VERTICAL
ELBOW CAP MK. EC2
4'-9"
CORNER
PANEL
2'-3"
4'-6"
WING
PANEL
WALE BEAM
x 9'-7" LG.
HW CAP MK HC3
x 9'-10" LG.
TYPE VI RIB x 24'-0" LG.
B
B
D
D
F
F
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
1. WALL PANEL NUMBERS ARE MARKED ON THE SOIL SIDE.
2. BOLT HEADWALL TO REINFORCING RIB AT END OF STRUCTURE.
3. SEE SHEETS 10-14 FOR REFERENCED SECTIONS AND ADDITIONAL DETAILS.
4. ALL 2'-3" DIMENSIONS ARE RELATIVE TO SECTION B-B.
5. ALL 4 1/2" DIMENSIONS ARE RELATIVE TO SECTION F-F.
6. ○ DENOTES BOLTS CONNECTION
7. ● DENOTES ANCHOR ROD CONNECTION
ALBC - OUTLET EXPANDED END VIEW
SEE DETAIL M
SEE DETAIL L
24'-0"
BASEWALL WIDTH
80° HORIZONTAL
18° VERTICAL
ELBOW CAP MK. EC3
2'-3"
4'-9"
CORNER
PANEL
4'-6"
WING
PANEL
WALE BEAM
x 9'-10" LG.
4'-6"
END
PANEL
4'-6"
CENTER
PANEL
1'-6"
CENTER
PANEL
4'-6"
CENTER
PANEL
4'-6"
CENTER
PANEL
4'-6"
END
PANEL
HW CAP MK HC1
24'-3" LG.
85° HORIZONTAL
29° VERTICAL
ELBOW CAP MK. EC4
4'-9"
CORNER
PANEL
2'-3"
4'-6"
WING
PANEL
WALE BEAM
x 10'-9" LG.
HW CAP MK HC5
x 11'-0" LG.
TYPE VI RIB x 24'-0" LG.
HW CAP MK HC4
x 10'-1" LG.
B
B
D
D
F
F
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
WHEN HEADWALLS ARE ORDERED FOR BOTH ENDS,
THE LENGTH OF STRUCTURE MUST BE A MULTIPLE OF 9"
0.150"
THICK PLATE
CORRUGATED
HEADWALL
REINFORCING RIB
FIELD DRILL HOLES FOR
ATTACHMENT OF THE
HEADWALL PLATE TO
THE END REINFORCING RIB
(ATTACH TO EVERY OTHER
CORRUGATION CREST ON
THE HEADWALL PANEL)
END OF
STRUCTURE
HEADWALL
CAP
Ø
4" x 10'-0" ANCHOR ROD
(HOLE THROUGH PLATE TO
BE FIELD DRILLED, RIB TO BE
SHOP PUNCHED)
GEOTEXTILE
(NOTE #4)
CORRUGATED
PLATE
SECTION D-D
HEADWALL ATTACHMENT TO
CROWN OF STRUCTURE
NOTES:
1) REVERSE CROWN RIBS AT THIS CORRUGATION IF NECESSARY FOR PROPER ANCHOR
ROD ATTACHMENT PLATE ORIENTATION.
2) NO SPLICE PLATES ARE USED FOR THE TYPE IV REINFORCING RIBS ATTACHED TO
THE CORRUGATED HEADWALL.
3) REINFORCING RIBS AT EACH END OF STRUCTURE MUST BE ORIENTED SUCH THAT
THE HEADWALL CAN BE PLACED BEHIND THEM AS SHOWN.
4) GEOTEXTILE PREVENTS INFILTRATION OF THE BACKFILL BETWEEN THE HEADWALL AND
STRUCTURE. A ROLL OF GEOTEXTILE IS PROVIDED FOR THIS PURPOSE.
TYPE VI RIB
" x 1-
" STEEL BOLTS & NUTS
ANCHOR ROD
ATTACHMENT PLATE
FIELD DRILL
AND BOLT
DETAIL D1-D1
NOTE #1
DETAIL D1-D1
" GALVANIZED NUT
" GALVANIZED BOLT
" DIA. ANCHOR ROD
" GALVANIZED NUT
FIELD DRILL HOLE
IN TYPE VI RIB
TYPE IV ARAP
TYPE VI CROWN RIB
TYPE IV ANCHOR ROD
7"
ATTACHMENT PLATE
(ARAP)
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
BOTTOM HOLE
IN HEADWALL PLATE
FIELD-DRILL THE HEADWALL CAP
TO MATCH THE BOTTOM HOLE IN
THE HEADWALL PLATE.
1"
FIELD-DRILL THE HEADWALL PLATE FOR RIB
ATTACHMENT.
TYPE VI RIB
USE A 2 X 4 TO ACHIEVE THE 1
" GAP,
THEN REMOVE THE WOOD BLOCK
ONCE THE HEADWALL CAP IS
FASTENED.
TOP OF HEADWALL PLATE
HEADWALL PLATE
HEADWALL
(CAP AND RIB ATTACHMENT)
X X
Y Y
" x 1-
" STEEL BOLTS,
FLAT WASHERS AND NUTS
(FIELD DRILLED)
OUTSIDE FACE OF WALL
& HEADWALL CAP
C WALL PANEL
L
HEADWALL/WINGWALL CAP
AT ATTACHMENT TO PANEL
DETAIL SECTION X-X
Ø
" x 10'-0" ANCHOR ROD
(FIELD DRILLED)
" x 1-
" STEEL BOLTS & NUTS
(FIELD DRILLED)
TYPE VI RIB
C WALL PANEL
L
TYPICAL ANCHOR ROD ATTACHMENT
AT HEADWALL SECTION Y-Y
" x 1-
" STEEL BOLTS & NUTS
FACE SIDE
SOIL SIDE
℄OF PLATE SEAM
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
TYPICAL PANEL LAP DETAIL
HEADWALL CAP
HEADWALL PLATE
A
L
P
N
E
L
L
" x 1-1/2" x STEEL BOLTS, FLAT
WASHERS AND NUTS
(FIELD DRILLED)
Ø
" x 10'-0" ANCHOR ROD
(FIELD DRILLED)
" x 1-1/2" STEEL BOLTS AND NUTS
(FIELD DRILLED)
HEADWALL PLATE
TYPE VI RIB
HEADWALL CAP
P
N
E
L
L
BACKFILL SIDE
FRONT OF WALL
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
CONTRACT
CONTECH
DRAWING
FOR APPROVAL
STRUCTURAL PLATE
TYPE: BOX
SIZE: 51R1
SPAN: 20'-6"
RISE: 7'-3"
LENGTH @ ℄: 18'-0"
SKEW
BEVEL
INLET OUTLET
PLATE THICKNESS: .125 (H)/.125(C)
REINFORCING RIB SPACING: AS SHOWN
REINFORCING RIB TYPE: AS SHOWN
NUMBER OF STRUCTURES: 1
HEADWALL / WINGWALL CAP AT ATTACHMENT TO PANEL DETAIL
SECTION X-X (ISOMETRIC VIEW)
TYPICAL ANCHOR ROD ATTACHMENT AT HEADWALL
SECTION Y-Y (ISOMETRIC VIEW)
L L
H
E I G
H T
V
R
I E
S
HOLE THROUGH PLATE
TO BE FIELD DRILLED (TYP.)
Ø3/4" x 12'-6" ANCHOR ROD
DEADMAN ANCHOR ALUMINUM
STRUCTURAL PLATE
0.150" (1'-8" x 2'-4 3/4") (TYP.)
0.150"
THICK PLATE
REINFORCING
RIB
REFER TO SECTION X-X FOR WINGWALL CAP ATTACHMENT
SECTION B-B
SINGLE DEADMAN ANCHOR
ATTACHMENT
T
O
T O
P
O
F
C
A P
SEE DETAIL "G"
SEE DETAIL "H"
" x 2" STEEL BOLT
HOLE THROUGH
WINGWALL PANEL
TO BE FIELD DRILLED
WALE
BEAM
WALE
NUT
SECURE ANCHOR ROD
WITH
" NUT
DETAIL H
SECURE ANCHOR ROD
WITH
" NUT
DETAIL G
THREADED FOR
" ANCHOR ROD
KF
JEM
I M
E R
L I N
P
R O
J E
C T
A
C T
I V
E
A
L U
M I N
L
V E
R T
D
R A
W I N
G S
C
O N
T R
A C
T
A
L B
C C
O N
A
D
P
M
SHEET NO.:
716372
SEQ. No.:
010GRIFFIN GOLF COURSE
GRIFFIN, GA
BRIDGE A
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by
Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of
Contech. Failure to comply is done at the user's own risk and
Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .