Addendum #3 - Bid C00124 - Staunton J&DR Courts Facility.pdf
PDF 35 MB Posted
- Attached to
- Bid #C00124 - J&DR COURTS FACILITY
- Solicitation number
- 60532
- Issued by
- Martinsville City, Virginia
About this file
This document is Addendum #3 to Bid C00124 for the construction of the Staunton J&DR Courts Facility, a project managed by the City of Staunton, Virginia. The addendum provides updated information and clarifications to the original bid solicitation.
The project scope includes the construction of a new J&DR court facility for the City of Staunton. The bid solicitation sets a deadline of October 15, 2022 for submissions. A mandatory pre-bid conference was held on September 15, 2022. The contract is expected to be awarded on November 15, 2022, with the successful bidder required to begin work within 30 days of the award. The contract term is 18 months, with no renewal options specified.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM NO. 03
STAUNTON J&DR COURTS FACILITY
CITY OF STAUNTON, VIRGINIA
STAUNTON CITY BID REQUEST NO.: C00124
ARCHITECT’S PROJECT NO.: 630874
ARCHITECT/ENGINEER RICHMOND, VIRGINIA
TIMMONS GROUP
CIVIL CONSULTANT RICHMOND, VIRGINIA
SHEN MILSOM AND WILKE
AUDIO VISUAL CONSULTANT ARLINGTON, VIRGINIA
March 26, 2024
STAUNTON, VIRGINIA
March 26, 2024 ADDENDUM NO. 03 Page 2 of 8
QUESTION RESPONSES: 10
1. Drawing A3.1.2 indicates two different notes for roller shades. Note A under general notes 11 indicates provide manual roller shades at all exterior windows UNO. Note 2 under Door, Frame 12 and Glazing Type Keynotes indicates Provide roller shades as indicated by dashed lines. Please 13 clarify which is correct. 14
RESPONSE: A3.1.2 - Keynote 2 and dashed lines removed. 15
2. Hazardous Materials Abatement – Section 024100 indicates hazardous materials abatement will be 16 performed as Part of this Project and there is also a Section 028000 in the Project Manual. (not 17 listed in the table of contents) Please advise of who is performing the abatement of the hazardous, 18 is it the Contractor or the Owner by separate contract? 19
RESPONSE: Refer to revisions per ADD 01R. Contractor is responsible for abatement. 20
3. Steel fabricators are requesting the structural revit model for bidding purposes. Please advise if the 21
CAD/Revit models for structural, civil, etc.. will be released for bidding purposes prior to award of 22 the project. 23
RESPONSE: We do not release these models during bidding - after bidding CAD release 24 agreements must be signed with the contractor. 25
4. Section 000515, 1.9, Taxes - notes that the Owner is exempt from State sales tax; however it is our 26 understanding that the Contractors still need to include sales tax in their bids. Please confirm sales 27 tax associated with the Work is to be included in the Contractors bid. 28
RESPONSE: The City is tax-exempt and shall not be charged taxes for the project. The 29 contractor must include any taxes they pay in the bid price. 30
5. Section 010200 General Sitework Requirements is missing page 1. Please provide. 31
RESPONSE: Refer to full section included in AD-03 32
6. Bonds – please advise if there will be any Erosion and Sediment Bonds and/or any other site bonds 33 required for this project. 34
RESPONSE: No E&S bond will be required for the project. 35
7. Section 014520 Testing, Adjusting, and Balancing – please confirm the Contractor/Subcontractors 36 are only to assist the TAB agent/agency and also confirm the TAB agent/agency is engaged and 37 paid for by the Owner 38
RESPONSE: The TAB agent is NOT paid for by the owner. Refer to specification section 39
014520. 40
8. Commissioning - please confirm the Contractor/Subcontractors are only to assist the 41
Commissioning agent/agency and also confirm the Commissioning agent/agency is engaged and 42 paid for by the Owner. 43
RESPONSE: Refer to Commissioning Specifications. 44
9. Section 018317 Exterior Building Enclosure Air Barrier Requirements, please confirm the 45
Contractor/Subcontractors are only to assist the Third Party Testing agency for this section of work 46 and also confirm the Third Party Testing agency for this work is engaged and paid for by the Owner. 47
RESPONSE: There is no testing required by this section. The Contractor is, however, 48 responsible for engaging ABAA to perform air barrier inspection/testing per Section 072736. 49
10. Floor Polishing & Waxing – please confirm the Owner is providing the floor polishing & waxing 50 for the new floors or advise if the Contractor’s are to include this in their pricing. 51
RESPONSE: Refer to specification section 096513 for polishing. No waxing specified. 52
11. Section 024113 Selective Site Demolition – paragraph 1.9, Payment for Utility 53
Removal/Relocations notes that “The Owner will pay for the relocation of”; please confirm the 54
Owner will pay for the relocation of all the listed utilities, items A thru F as required. 55
RESPONSE: Relocation of existing services and associated infrastructure identified in the 56 contract documents is the responsibility of the contractor. Costs for reconnection of those 57 services by third party utility purveyors to be paid for by the Owner. 58
March 26, 2024 ADDENDUM NO. 03 Page 3 of 8
12. Section 312000 Earth Moving – paragraph 1.5 notes the site is classified to subgrade paragraph and 59 paragraph 1.5, E, 1 notes the additional excavation shall be counted toward the unit price 60 allowances established in the Bid Form. However, the Bid Form does not provide any site related 61
Unit Prices. Please provide the unit prices that are related to the Additional Work. 62
RESPONSE: Site is unclassified to subgrade, refer to quantity allowances in section 012100 63 and the bid form. 64
13. Section 329200 Lawns and Grasses – paragraph 1.9, B notes “areas under existing modular 65 buildings removed by the Owner”; please confirm this does not apply to this project or advise of 66 these locations. 67
RESPONSE: Confirmed. This note does not apply to this project. 68
14. The existing parking lots to remain appear to be in very rough condition with cracks, potholes, etc.. 69 and there is a note on C4.0 noting “Damaged asphalt beyond the extents of mill & overlay to be 70 replaced at the contractor’s expense”. Please confirm the contractors are not responsible for 71 replacing the existing parking lots/paving that is already in very rough condition and/or already 72 damaged. 73
RESPONSE: Refer to drawings in AD-03. Contractors are not responsible for any 74 remediation work outside of what is delineated on the plans, however, if areas outside of what 75 is delineated are further damaged, it will need to be replaced at the contractors expense. 76
15. Section 042000, 2.01, 4, notes decorative concrete ground face block, however it does not provide 77 a ground face manufacturer/basis of design selection. Please provide a basis of design if the project 78 requires decorative ground face block. We are not currently finding any ground face block on the 79 exterior elevations or on the finish schedule. Please advise of the intent. 80
RESPONSE: Refer to revised specification section 042000 included in AD-03. 81
16. Section 042000, 2.02 does not provide a brick manufacturer/basis of design selection. Please 82 provide a basis of design brick or provide a brick allowance to be used for bidding purposes. 83
RESPONSE: Refer to revised specification section 042000 included in AD-03. 84
17. Precast and cast stone trim units – drawing A4.2 notes cast stone bands and architectural precast 85 concrete coping, A5.2.2 provides APC shapes, and the project manual provides an architectural 86 precast concrete scope, but not a cast stone specification. Please advise of the intent for precast 87 versus cast stone trim units. 88
RESPONSE: Refer to drawings A4.1, A4.2, A5.2.2 and specification section 047200 in AD-89
03. All units will be cast stone. 90
18. Can the AWI QCP requirement be removed and replaced with a specification requirement to 91 provide millwork fabrication and installation that is commensurate with the AWI Standards? 92
RESPONSE: AWI QCP is required. 93
19. Section 126723. Referencing the courtroom benches specified, please advise on what wood species 94 the benches should be. 95
RESPONSE: Refer to revised specification section 126723 in AD-03. 96
20. Drawing C4.0, A1.1.1. Referencing the flagpoles shown on the drawings referenced above, please 97 provide the total height of the flagpoles, and provide a detail for the concrete foundation. 98
RESPONSE: Refer to drawing A1.1.1 in AD-03. 99
21. Are Civil CAD Files available? 100
RESPONSE: We do not release these models for bidding - after bidding CAD release 101 agreements must be signed with the contractor. 102
22. Is there a REVIT model available to be issued to the contractors? 103
RESPONSE: We do not release these models for bidding - after bidding CAD release 104 agreements must be signed with the contractor. 105
23. Please confirm that the top railing molding and handrail for glass Guardrail (3/A6.1.3) is not 106 wood/millwork. 107
RESPONSE: Refer to specification section 057000 in AD-03 108
24. Please confirm that the wood hatch on 6/A6.1.5 ramp section is not required paneling. 109
March 26, 2024 ADDENDUM NO. 03 Page 4 of 8
RESPONSE: Refer to drawing A6.1.5 in AD-03. Paneling is not required on the ramp side of 110 the wall. 111
25. Please confirm tags #2 and #8 on 6/A8.2.2 are all accurate as drawn. The inside of some areas are 112 tagged to be painted (#8) while the far right is tagged to have a veneer finish (#2). 113
RESPONSE: Refer to drawing A8.2.2 in AD-03. 114
26. Reference 5/A7.2.1. Please clarify the extent of wall paneling. Does it go above the crown as 115 hatched? Is it above the chair rail as hatched in some areas? If so, does it go behind the acoustic 116 panels? 117
RESPONSE: Refer to drawing A7.2.1 in AD-03. 118
27. The site lighting layout on the C4.1 differs from the electrical site plan E1.0. Which is correct? 119
RESPONSE: Refer to drawing E1.0 in AD-03. 120
28. DRAWING A3.3.1 SPECIFICATION 111900. Detention door and frame schedule calls for a 121 shutter to be provided on doors D152, D154, D158, D255, D259, D260. Please provide a detail for 122 the shutter, as well as any security hardware requirements. 123
RESPONSE: Refer to Detail 12/A3.3.1 on revised Drawing A3.3.1. 124
29. SHEET C-2.0 calls out areas of the access road and asphalt parking lot to be "Milled and Overlaid". 125
Sheet C-4.0 highlights those same areas as new heavy-duty asphalt which the detail on C-1.1 shows 126 as 8" of stone base and 2" of surface asphalt. 127
RESPONSE: Refer to revised drawings. Mill and overlay have been removed. 128
30. There are no grade changes in these areas except for the entrance where it has an exploded view 129 showing specific regrading. There needs to be clarity as to whether the Mill and Overlay is to be 130 utilized or full excavation, 8" of stone base and 2" of surface. 131
RESPONSE: Refer to revised drawings. Mill and overlay have been removed. 132
31. In the entrance area near West Beverley, Sheet C5.0 calls for "Existing Asphalt to Remain" in the 133 crosswalk and parking areas. This area is also left out of the areas to be milled and overlaid on 134 sheet C-2.0, but on Sheet C-4.0 that same area is shaded as if it is new heavy-duty Asphalt. Which 135 is correct? 136
RESPONSE: Refer to revised drawings. Mill and overlay have been removed. 137
32. L2.0 On sheet L2.0 in the Notes, Note 2. Says the owner is responsible for maintaining shrubs and 138 trees and also replacing any that die. Note 4-6 talks about maintenance but does not specify who is 139 responsible. So, note 2 and 4-6 seem to contradict themselves. Plus, the landscaper should replace 140 any shrubs or trees that die. Should the contractor assume warranting shrubs and trees for 1 yar 141 and the Owner doing the maintenance? Also, can the contractor assume all the evergreens along 142 the border would just have individual mulch rings around them? 143
RESPONSE: Include a 1 year warrantee on shrubs & trees. Owner shall be responsible for 144 maintenance of the trees, shrubs, landscape after it is accepted. Include a mulch ring on the 145 evergreen screening trees individually. 146
33. Please state the anticipated award date and the anticipated project start date. 147
RESPONSE: Award date tentatively week of 8 April, NTP week of 15 April. 148
34. A7.3.1 Should room 166, Hold Toilet, receive a detention equipment item D1 or D2 single or 149 double detention mirror? 150
RESPONSE: A detention mirror is not required in this space. 151
35. SE1.1 Please advise if pedestrian gates G6 & G7 are to be controlled and monitored by the security 152 electronics system. If yes, are these tow gates to be equipped with hardware set SH12 per spec 153 section 111960? 154
RESPONSE: Refer to Drawing SE2.1 for gate control status. Provide Security Hardware Set 155
SH12 at each gate, per Section 111960. 156
36. Addendum 1R detail 1 on Sheet 3.0.3 shows a resilient base which I believe is a special profile 157 from Roppe. The specs do not indicate any special profile, just standard 4-inch cove base. Is the 158 special profile desired and if so, can we get a product name? 159
RESPONSE: Refer to revised specification section 096513 in AD-03 160
March 26, 2024 ADDENDUM NO. 03 Page 5 of 8
37. Spec 096513 Resilient base and accessories, regarding the stair covering a rubber stringer is listed 161 in the products. The manufacturer of the specified tread does not make a matching stringer and 162 stringer is not normally used where there is a mental stringer. Please let us know if a rubber stringer 163 is desired and if so, what product. 164
RESPONSE: Refer to revised specification section 096513 in AD-03 165
38. On the finish plan and finish schedule room 218 Elec calls for C-Tile (carpet tile). Is that correct? 166
RESPONSE: Refer to updated drawing in AD-03. 167
39. 096519 Resilient Tile calls for moisture mitigation, but I believe this is part of a separate allowance 168 and not part of the base bid. Am I correct? 169
RESPONSE: Indicate as separate allowance. 170
40. Referencing the AIA General Conditions, subparagraph 15.1.7 and the supplementary general 171 conditions revising this subparagraph, please reinstate the original AIA subparagraph 15.1.7 and 172 remove the revision from the project documents. 173
RESPONSE: The City will leave the supplementary language unchanged at 15.1.7. 174
41. Could Delta Controls be added to the list of manufacturers shown in 230900 2.1A? 175
RESPONSE: Yes 176
42. Drawing A3.1.2 General Note A. states, " Provide Manual Roller Shades at all exterior windows 177
UNO. Door, Frame and Glazing Type Keynote 2. stats, "Provide Roller Shades as indicated by 178
Dashed Lines." 1. Are roller shades only required at Types notes with Keynote 2? 2. Are roller 179 shades only required at the Glazing sections with dashed lines? 3. May we exclude Shades at: 180
Doors, Vestibules, stairs, interior glazing? 4. May we exclude shades at: Vestibule 100? 5. Attached 181 is our Shade Plan Takeoff Drawing. Please confirm accuracy. 182
RESPONSE: Refer to drawing A3.1.2 in AD-03. Keynote 2 and dashed lines removed. 183
43. Spec section 122400 2.0.2 B. 6 a specifies, " Fascia". This is not detailed in the drawings. May 184 we exclude? 185
RESPONSE: Refer to revised specification section 122400 in AD-03. Refer to "Closure Clip" 186 that houses the roller shade mechanism shown in detail 12/A5.2.3. 187
44. Spec section 122400 2.0.2 B. 6 c specifies, " Ceiling pockets." Detail 12/A5.2.3 articulates "Custom 188 sided panel cover by Ceiling Perimeter System manufacturer," and " Ceiling Perimeter System 189
Perimeter Pocket." The panel cover is not available by the Division 12 manufacturers. May be 190 exclude? The pocket is available, however, for consistency, it is recommended that Division 09 191 provide both (Panel Cover and Pocket) for consistency/continuity. May we exclude Pocket? Are 192 panel covers and pockets both color white? 193
RESPONSE: Refer to revised specification section 122400 in AD-03. The "custom sided panel 194 cover" is required due to ceiling heights and recessed pockets that have been noted as, 195
“varies," therefore a specific size will not work for all applications. Panel covers are to be 196
VIF for accuracy for each panel cover size throughout. A full range of standard colors are to 197 be selected by the architect. 198
45. The project manual table of contents list Section 285220 Interview Room Recording System; 199 however, it does not appear that we actually have that Section in the manual. 200
RESPONSE: Delete specification section 285220. 201
46. Please confirm which A305 version should be used. 202
RESPONSE: Refer to specifications in AD-03. 203
47. Addendum 1R, noted a revised Section 285000 Security Control System, however it was not 204 included in the addendum. 205
RESPONSE: Refer to specifications in AD-03. 206
48. Per the electrical service riser shown on Drawing E5.1 feeders 100Y and 225Y are to be installed 207 between the generator and transfer switches. The detail for Duct bank B-B doesn't indicate either 208 of the conduit sizes associated with 100Y or 225Y. Please provide clarification of required conduit 209 sizes and the intent of each conduit shown in the B-B duck bank detail. 210
RESPONSE: Refer to revised drawing E5.1 in AD-03. 211
March 26, 2024 ADDENDUM NO. 03 Page 6 of 8
49. Referencing the excavation scope, it does not clearly state in the bid documents to date what the 212 intentions are of being an unclassified or classified site. There are currently no unit prices for rock 213 or unsuitable materials on the bid form. There are no mention that I see of any allowances or units 214 clearly stated in section 012100, 012100 or 012200. Earthwork section 312000 Definition 1.4 A 215 mentions excavation (except for rock) but the Execution section 3 does not clearly spell out 216 excavations or compensation. Excavation 312000 section part 1.5 Additional Work - part A refers 217 to Paragraph 4.3.4 of the General Conditions for conditions of additional excavation work, yet there 218 is no section 4.3.4 in the General Conditions or reference to excavations in the General Conditions. 219
Can we clearly ask if units can be applied to the bid form? Can the site be fully classified or at least 220 classified BELOW subgrade for rock or unsuitable materials. 221
RESPONSE: Refer to question 12. Site is unclassified to subgrade, refer to quantity 222 allowances in section 012100 and the bid form. 223
50. For the BAS Controls in DIV 23. Is it the intent that the UH’s and CUH’s are to be controlled and 224 monitored on the BAS system? The control flow diagrams to mention it, the sequence of operations 225 reference them, but the equipment specs call for integral thermostats. 226
RESPONSE: UH and CUH to be controlled by BAS system. Equipment spec revised to 227 include unit mounted thermostats rather than integral thermostats. 228
51. Spec 230993, section 2.17 calls for Fire Alarm Monitoring, but just leaves it to monitor dry 229 contacts. Can you confirm the number of dry contacts? Does this system need to be integrated in 230 to the BAS? 231
RESPONSE: System is not integrated with control to the BAS - just monitored by the BAS. 232
Dry contacts for simple status of fire alarm (alarm/normal) 233
52. Spec 230900 , section 2.1 allows for Scheider Electric, but then the following paragraphs refer to 234
Niagra N4. Is a Scheider Electric Head end acceptable for this project or should it be a Tridium 235 front end? 236
RESPONSE: Paragraph updated to remove the specific manufacturer framework/head ends 237 and leave it open to multiple manufacturers set up 238
MODIFICATIONS TO THE PROJECT MANUAL AND DRAWINGS: 240
DELETE the previously issued Documents indicated below in their entirety and SUBSTITUTE the 241 revised Documents in their entirety, noted as Addendum 03, dated March 26, 2024. 242
March 26, 2024 ADDENDUM NO. 03 Page 7 of 8
SECTION 000110 – TABLE OF CONTENTS 243
SECTION 000301 – GENERAL CONSTRUCTION BID FORM 244
SECTION 004513 – CONTRACTOR’S QUALIFICATION STATEMENT (AIA DOCUMENT 245
A305) WITH EXHIBITS 246
SECTION 010200 – GENERAL SITE WORK 247
SECTION 012100 – ALLOWANCES 248
SECTION 012200 – UNIT PRICES 249
SECTION 019113 – GENERAL COMMISSIONING 250
SECTION 019113 – COMMISSIONING PLAN PART 2 251
SECTION 024113 – SELECTIVE SITE DEMOLITION 252
SECTION 042000 – UNIT MASONRY 253
SECTION 047200 – CAST STONE MASONRY 254
SECTION 057000 – DECORATIVE METAL RAILING 255
SECTION 081416 – FLUSH WOOD DOORS 256
SECTION 081433 – STILE AND RAIL WOOD DOORS 257
SECTION 093000 – TILING 258
SECTION 096513 – RESILIENT BASE AND ACCESSORIES 259
SECTION 096519 – RESILIENT TILE FLOORING 260
SECTION 097200 – WALL COVERING 261
SECTION 098414 – ACOUSTIC STRETCH-FABRIC WALL AND CEILING SYSTEMS 262
SECTION 122400 – WINDOW SHADES 263
SECTION 126723 – COURTROOM BENCH SEATING 264
SECTION 220800 – PLUMBING SYSTEMS COMMISSIONING 265
SECTION 230800 – MECHANICAL SYSTEMS COMMISSIONING 266
SECTION 230900 – BUILDING AUTOMATION SYSTEM 267
SECTION 238239 – UNIT HEATERS 268
SECTION 260800 – ELECTRICAL SYSTEMS COMMISSIONING 269
SECTION 285000 – SECURITY CONTROL SYSTEM 270
SECTION 312000 – EARTH MOVING 271
DRAWING C1.1 – NOTES AND DETAILS 272
DRAWING C2.0 – EXISTING CONDITIONS AND DEMOLITION 273
DRAWING C4.0 – LAYOUT PLAN 274
DRAWING C4.1 – UTILITY PLAN 275
DRAWING A1.1.1 – ARCHITECTURAL SITE PLAN 276
DRAWING A2.0.0 – ADD ALTERNAT NO 1 PARTIAL BUILDING DEMO PLAN AND 277
DETAILS 278
March 26, 2024 ADDENDUM NO. 03 Page 8 of 8
DRAWING A3.0 – FINISH SCHEDULE 279
DRAWING A3.0.1 – FIRST FLOOR PATTERN AND FINISH PLAN 280
DRAWING A3.0.2 – SECOND FLOOR PATTERN AND FINISH PLAN 281
DRAWING A3.1.2 – DOOR, FRAME AND GLAZING TYPES 282
DRAWING A3.3.1 – DETENTION DOOR & WINDOW SCHEDULE & DETAILS 283
DRAWING A4.1 – BUILDING ELEVATIONS 284
DRAWING A4.2 – BUILDING ELEVATIONS 285
DRAWING A5.2.2 – SECTION DETAILS 286
DRAWING A6.1.3 – ENLARGD RAMP PLANS & DETAILS 287
DRAWING A6.1.5 – ENLARGED RAMP PLANS & DETAILS 288
DRAWING A7.2.1 – ENLARGED FIRST FLOOR COURTROOM AND ELEVATIONS 289
DRAWING A7.2.2 – ENLARGED SECOND FLOOR COURTROOM AND ELEVATIONS 290
DRAWING A8.1.0 – FIRST FLOOR AND SECOND FLOOR LOBBY ELEVATIONS 291
DRAWING A8.2.2 – COURTROOM BENCH PLAN, SECTION & DETAILS 292
DRAWING A8.2.3- COURTROOM CASWORK DETAILS 293
DRAWING S1.1.1 – FOUNDATION PLAN 294
DRAWING S2.1.1 – SECOND FLOOR FRAMING PLAN 295
DRAWING S4.1.1 – FRAMING SECTIONS 296
DRAWING S4.2.2 – FRAMING SECTIONS 297
DRAWING E1.0 – SITE PLAN – ELECTRICAL 298
DRAWING E5.1 – POWER ONE-LINE DIAGRAM 299
REFER TO DRAWINGS ATTACHED TO THE END OF THIS ADDENDUM 301
END OF ADDENDUM NO 03 303
Architect’s Project No: 630874
TABLE OF CONTENTS (*AD-01R) (*AD-03) TOC - 1
TABLE OF CONTENTS (*AD-01R) (*AD-03)
DIVISION 00 PROCUREMENT AND CONTRACTING REQUIREMENTS
Invitation to Bid
Instructions to Bidders (AIA Document A701)
000101 Supplemental Instructions to Bidders (*AD-01R)
Prebid Question Form (*AD-01R)
Bid Form (*AD-01R) (*AD-03)
Bid Bond
004513 Contractor's Qualification Statement (AIA Document A305) with Exhibits(*AD-03)
000515 City of Staunton / VPPA Project Requirements
000516 Employment Verification Act
Standard Form of Agreement Between Owner and Contractor (AIA Document A101)
Performance Bond
Payment Bond
General Conditions of the Contract for Construction (AIA Document A201)
000750 Supplementary General Conditions
SPECIFICATIONS
DIVISION 1 – GENERAL REQUIREMENTS
010200 General Sitework Requirements(*AD-03)
011000 Summary
012000 Price and Payment Procedures
012100 Allowances(*AD-03)
012200 Unit Prices(*AD-03)
012300 Alternates (*AD-01R)
012500 Substitution Procedures
Substitution Request Form (After Receipt of Bids)
013000 Administrative Requirements
013216 Construction Progress Schedule
014000 Quality Requirements
014200 Definitions and Reference Standards
014520 Testing, Adjusting, and Balancing for HVAC
015000 Temporary Facilities and Controls
016000 Product Requirements
017000 Execution and Closeout Requirements
017419 Construction Waste Management and Disposal
017800 Closeout Submittals
017900 Demonstration and Training
018119 Indoor Air Quality Requirements
018317 Exterior Building Enclosure Air Barrier Requirements
019113 Commissioning Requirements(*AD-03)
TABLE OF CONTENTS (*AD-01R) (*AD-03) TOC - 2
DIVISION 2 – EXISTING CONDITIONS
024100 Demolition
024113 Selective Site Demolition(*AD-03)
028000 Hazardous Materials Remediation (*AD-01R)
DIVISION 3 – CONCRETE
033000 Cast-In-Place Concrete
034500 Precast Architectural Concrete (*AD-03)
DIVISION 4 – MASONRY
042000 Unit Masonry(*AD-03)
047200 Cast Stone Masonry (*AD-03)
DIVISION 5 – METALS
051200 Structural Steel Framing
052100 Steel Joist Framing
053100 Steel Decking
054000 Cold-Formed Steel Framing – Structural (CFSF-S)
054003 Continuous Insulation (CI) Framing System, Clipped
055000 Metal Fabrications
055100 Metal Stairs
055133 Metal Ladders
055213 Pipe and Tube Railings
057000 Decorative Metal Railing(*AD-03)
DIVISION 6 – WOOD PLASTICS AND COMPOSITES
061000 Rough Carpentry
064100 Architectural Woodwork and Casework (*AD-01R)
064400 Custom Courts Woodwork and Casework
DIVISION 7 – THERMAL AND MOISTURE PROTECTION
071300 Sheet Waterproofing
072100 Thermal Insulation
072736 Sprayed Foam (SPF) Air Barrier
074213.23 Metal Composite Material Wall Panels
075423 TPO Membrane Roofing
076200 Sheet Metal Flashing and Trim
077100 Roof Specialties
077200 Roof Accessories
078400 Firestopping
078426 Thermal Barriers for Plastics
079200 Joint Sealants
DIVISION 8 – OPENINGS
081113 Steel Doors and Frames
081416 Flush Wood Doors (*AD-03)
081433 Stile and Rail Wood Doors (*AD-03)
083100 Access Doors and Panels
083323 Overhead Coiling Doors
TABLE OF CONTENTS (*AD-01R) (*AD-03) TOC - 3
084313 Aluminum-Framed Storefronts
084413 Glazed Aluminum Curtain Walls
085619 Pass Windows
085653 Security Windows
087100 Door Hardware
087113 Power Door Operators
088000 Glazing
088813 Fire-Rated Glazing
089100 Louvers
DIVISION 9 – FINISHES
092216 Cold Formed Steel Framing - Non-Structural (CFSF-NS)
092900 Gypsum Board
093000 Tiling(*AD-03)
095100 Acoustical Ceilings
095753 Security Ceiling Assemblies
096513 Resilient Base and Accessories(*AD-03)
096519 Resilient Tile Flooring(*AD-03)
096623 Resinous Matrix Terrazzo Flooring
096813 Tile Carpeting
097200 Wall Coverings(*AD-03)
098414 Acoustic Stretched-Fabric Wall and Ceiling Systems(*AD-03)
099100 Painting
DIVISION 10 – SPECIALTIES
101400 Signage
102113.17 Phenolic Toilet Compartments
102600 Wall and Door Protection
102800 Toilet and Bath Accessories
104400 Fire Protection Specialties
107300 Protective Covers
107500 Flagpoles
DIVISION 11 – EQUIPMENT
111400 Pedestrian Control Equipment
111900 Detention Equipment
111910 Custom / Security Hollow Metal Work
111950 Security Glass and Glazing
111960 Security Hardware
DIVISION 12 – FURNISHINGS
122400 Window Shades(*AD-03)
126723 Courtroom Bench Seating(*AD-03)
DIVISION 13 – SPECIAL CONSTRUCTION (not used)
DIVISION 14 – CONVEYING SYSTEMS
142400 Hydraulic Elevators
TABLE OF CONTENTS (*AD-01R) (*AD-03) TOC - 4
DIVISION 21 – FIRE SUPPRESSION
210500 Common Work Results for Fire-Suppression
211000 Water-Based Fire-Suppression Systems
DIVISION 22 – PLUMBING
220500 Common Work Results for Plumbing Piping
220513 Motors for Plumbing Equipment
220516 Expansion Fittings and Loops for Plumbing Piping
220517 Sleeves and Sleeve Seals for Plumbing Piping
220519 Meters and Gages for Plumbing Piping
220523 General-Duty Valves for Plumbing Piping
220529 Hangers and Supports for Plumbing Piping and Equipment
220553 Identification for Plumbing Piping and Equipment
220700 Plumbing Insulation
220800 Plumbing Systems Conditioning(*AD-03)
221113 Facility Natural Gas Piping
221116 Domestic Water Piping
221119 Domestic Water Piping Specialties
221125 Circulating Pumps
221316 Sanitary Waste and Vent Piping
221319 Sanitary Waste Piping Specialties
221413 Facility Storm Drainage Piping
221423 Storm Drainage Piping Specialties
221429 Sump Pumps
223400 Fuel-Fired Domestic Water Heaters
224000 Plumbing Fixtures
224500 Emergency Plumbing Fixtures
224600 Security Plumbing Fixtures
DIVISION 23 – MECHANICAL
230500 Common Work Results for HVAC
230513 Motors for HVAC Equipment
230514 Variable Speed Drives
230516 Expansion Fittings and Loops for HVAC Piping
230517 Sleeves and Sleeve Seals for HVAC Piping
230519 Meters and Gages for HVAC Piping
230523 General-Duty Valves for HVAC Piping
230529 Hangers and Supports for HVAC Piping and Equipment
230548 Vibration Control for HVAC
230553 Identification for HVAC Piping and Equipment
230700 HVAC Insulation
230800 Mechanical Systems Commissioning(*AD-03)
230900 Building Automation System
230993 Sequence of Operations for HVAC Controls
232113 Hydronic Piping
232123 Hydronic Pumps
232300 Refrigerant Piping
233113 Metal Ducts
TABLE OF CONTENTS (*AD-01R) (*AD-03) TOC - 5
233300 Air Duct Accessories
233423 HVAC Power Ventilators
233600 Air Terminal Units
233713 Diffusers, Registers, and Grilles
234100 Particulate Air Filtration
235100 Breechings, Chimneys, and Stacks
235216 Condensing Boilers
237413 Packaged Outdoor Central Station Air Handling Units
238126 Ductless Mini-Split Air Conditioning Units
238239 Unit Heaters(*AD-03)
DIVISION 25 – INTEGRATED AUTOMATION (not used)
DIVISION 26 – ELECTRICAL
260519 Low-Voltage Electrical Power Conductors and Cables
260526 Grounding and Bonding for Electrical Systems
260529 Hangers and Supports for Electrical Systems
260533 Raceways and Boxes for Electrical Systems
260543 Underground Ducts and Raceways for Electrical Systems
260544 Sleeves and Sleeve Seals for Electrical Raceways and Cabling
260553 Identification for Electrical Systems
260572 Overcurrent Protective Device Short-Circuit Study
260573 Overcurrent Protective Device Coordination Study
260574 Overcurrent Protective Device Arc-Flash Study
260800 Electrical Systems Commissioning(*AD-03)
260923 Lighting Control Devices
260943 Relay-Based Lighting Controls
262200 Low-Voltage Transformers
262413 Switchboards
262416 Panelboards
262714 Utility Service Entrance (DVP)
262726 Wiring Devices
262813 Fuses
262816 Enclosed Switches and Circuit Breakers
262913 Enclosed Controllers
263213 Engine Generators
263600 Transfer Switches
264113 Lightning Protection for Structures
264313 Surge Protection for Low-Voltage Electrical Power Circuits
265119 LED Interior Lighting
265613 Lighting pole and standards
265619 LED Exterior Lighting
DIVISION 27 – COMMUNICATIONS
270500 Common Work Results for Communications
270528 Pathways for Communications Systems
271100 Communications Equipment Room Fittings
271300 Communications Backbone Cabling
TABLE OF CONTENTS (*AD-01R) (*AD-03) TOC - 6
271500 Communications Horizontal Cabling
275227 Elevator 2-way Intercom System
276410 RF BDA-Based Signal Booster System
DIVISION 28 – ELECTRONIC SAFETY AND SECURITY
280500 Common Work Results for Electronic Safety and Security
283111 Digital, Addressable Fire-Alarm System
285000 Security Control System (*AD-01R) (*AD-03)
285010 PLC, Network, and UPS Systems
285020 Video Graphical User Interface
285030 Cabinets and Enclosures
285100 Audio Communication Systems
285200 Video Surveillance
285220 Interview Room Recording System(*AD-03)
285260 Video Management System
285300 Access Control System (*AD-01R)
285400 Duress – Misc. Systems
285500 Auxiliary Control Systems
285900 Security Management Server
DIVISION 31 – EARTHWORK
312000 Earth Moving(*AD-03)
DIVISION 32 – EXTERIOR IMPROVEMENTS
321216 Asphalt Paving
321313 Site Concrete
321700 Pavement Markings, Signs, and Specialties
323114 Security Chain-Link Fences and Gates
329200 Lawns & Grasses
329300 Exterior Plants
DIVISION 33 – UTILITIES
331000 Exterior Water System
333000 Sanitary Sewerage
334100 Storm Utility Drainage Piping
334200 Foundation Drainage Systems
DIVISION 34 – TRANSPORTATION (not used)
APPENDIX A: Asbestos and Lead Paint Survey Report (*AD-01R)
APPENDIX B: Geotechnical Engineering Study (*AD-01R)
END OF TABLE OF CONTENTS
Architect’s Project No: 630874
City of Staunton, VA 000301-1
J&DR Courts Facility General Construction Bid Form
Moseley Architects Project No: 630874
City of Staunton IFB#C00124
BID FORM - GENERAL CONSTRUCTION – Architect’s Project No: 630874 (*AD-01R) (*AD-03)
City of Staunton IFB#C00124
DATED: ____________________________ Bidder’s Name and Address (Print or Type)
(Bidder to insert date bid submitted)
City of Staunton, VA
116 W. Beverley St
Staunton, VA 24401 _______________________________________
To Whom It May Concern:
This Bid is submitted in accordance with your Advertisement inviting Bids to be received for the General
Construction Work for Staunton J&DR Courts Facility, City of Staunton, VA.
Having carefully examined the Contract Documents as defined in Article 1 of the Agreement, bound in the
Specifications, and including the Addenda enumerated in the Bid, which are incorporated with these documents indicating various conditions affecting this Contract, the undersigned herein agrees to furnish all materials, perform all labor and do all else necessary to complete the Contract for the above-named
Project in accordance with said Contract Documents for:
Total Base Bid Project Cost for All General Construction (INCLUDING ALLOWANCES)
___________________________________________________________________ DOLLARS
Accompanying this Bid is a certified check, bank cashier's check, bank treasurer's check or Bid Bond required by Paragraph 4.2 of the Instructions to Bidders which is deposited as a bid guarantee, and is to be retained by you and applied as provided in Paragraph 4.2.1 of the Instructions to Bidders, in case the undersigned shall default in executing the Contract or in furnishing the required Bonds and insurance certificates within the time specified by these Contract Documents.
The undersigned hereby certifies that this Bid is genuine, and is not a sham or collusive, or made in the interest of, or on behalf of any person, firm or corporation not herein named, and that the undersigned has not directly or indirectly induced or solicited any bidder to refrain from bidding and that the undersigned has not in any manner sought by collusion to secure for itself, any advantages over any other bidder.
The undersigned, intending to be legally bound, agrees that this Bid shall be irrevocable and shall remain subject to your acceptance for 60 days after the date set for bid opening.
Architect’s Project No: 630874
City of Staunton, VA 000301-2
J&DR Courts Facility General Construction Bid Form
Moseley Architects Project No: 630874
City of Staunton IFB#C00124
It is hereby certified that the undersigned is the only person(s) or entity(ies) interested in this Bid as
Principal, and that the Bid is made without collusion with any person, firm or corporation. The Bidder hereby agrees to furnish surety company bonds in the form incorporated in the Contract Documents, in the amount of one hundred percent (100%) of the Contract Price for the Performance Bond and the
Payment Bond as surety against defects or inferior materials or workmanship which may develop during the period of one (1) year from the date of completion and acceptance of the Work performed under the
Contract, within ten (10) days after notice by the Owner of the intention to award the Contract and execute the Agreement and furnish evidence of required insurance coverage, upon request, within ten
(10) days after mailing by the Owner of Notice of Intent to Award, and to commence work within forty-eight (48) hours after receipt of Notice to Proceed.
The Bidder guarantees that, if awarded a Contract, it will furnish and deliver all materials, all specified temporary facilities and controls, tools, equipment, tests, and transportation, to secure all permits and licenses, to do and perform all labor, superintendence, and all means of construction, pay all fees (unless specifically noted otherwise), and do all incidental Work, and to execute, construct and finish, in an expeditious, substantial and workmanlike manner in accordance with the plans and specifications, to the complete satisfaction and acceptance of the Owner for the price herein stated.
It is understood that the City of Staunton reserves the right to reject any or all Bids or Proposals, or parts thereof, or items thereof, and to waive technicalities required for the best interests of the Owner.
The undersigned submits this Bid with the full knowledge of the Contract requirements and hereby agrees that Work of this Project, under this Contract, shall be substantially completed by November 1st, 2025, which period shall be the essence of the Contract. Each phase of construction will have its own substantial completion date. See Section 011000 Summary of Work.
The Bidder agrees that it will not assign its Bid or any of its rights or interests hereunder without written consent of the Owner.
The undersigned Contractor agrees to furnish all labor and materials for any additional work ordered by the Owner, and for which no pre-agreed price has been fixed, for the net cost of all labor and materials furnished plus the contracted markup noted in Article 6 of the Supplementary General Conditions.
THE BID FORM AND THE FOLLOWING ATTACHMENTS SHALL BE SUBMITTED IN DUPLICATE:
1. Two (2) Bid Security
2.
3.
4.
Two (2)
Two (2)
Two (2)
Contractor’s Qualification Statement (AIA Document A305)
Virginia SCC number
Non-Collusion Affidavit
Architect’s Project No: 630874
City of Staunton, VA 000301-3
J&DR Courts Facility General Construction Bid Form
Moseley Architects Project No: 630874
ALLOWANCES: The Instructions to Bidders and the Contract Documents comprising the plans and specifications, and all documents bound therewith, together with all Addenda thereto, shall apply to all
Allowances and Unit Prices as listed in Division 1 Sections “Allowances”, “Unit Prices”, and as listed below:
Lump Sum Allowance #1: Interior and Exterior Panel Signage $50,000.
Quantity Allowance #1: Moisture Vapor Treatment (MVT):
Provide quantity of 20,000 square feet (sf) at $____________ per sf (in-place unit price/measurement);
for a total allowance amount of $_______________________ (figures only)
Quantity Allowance #2: Additional Excavation: (*AD-03)
Provide quantity of 200 cubic yards (cy) at $____________ per cy (in-place unit price/measurement);
Quantity Allowance #3: Additional Excavation for Trenches and Footings: (*AD-03)
Provide quantity of 100 cubic yards (cy) at $____________ per cy (in-place unit price/measurement);
Quantity Allowance #4: Mass Rock Excavation: (*AD-03)
Provide quantity of 25 cubic yards (cy) at $____________ per cy (in-place unit price/measurement);
Quantity Allowance #5: Trench Rock Excavation: (*AD-03)
Provide quantity of 10 cubic yards (cy) at $____________ per sf (in-place unit price/measurement);
The Owner reserves the right to accept or reject any and all Unit Prices stipulated on the Bid Form.
Architect’s Project No: 630874
City of Staunton, VA 000301-4
J&DR Courts Facility General Construction Bid Form
ALTERNATE BID PRICE: (Reference Section 012300 – Alternates) (*AD-01R)
1. Alternate #1 Bid Price: Partial Building Demolition: Provide all work associated with Partial
Building Demolition, the existing structure is a single-level steel-framed building consisting of steel roof deck. The demolition shall consist generally of roof structure, steel columns, and exterior and interior walls, in strict accordance with the Bid Documents; Lump Sum + Lump Sum Allowances + associated
Quantity Allowances
$ (Figures only)
ADDENDA
The undersigned hereby acknowledge receipt of following Addenda and has prepared this bid accordingly:
ADDENDUM #_______ Dated_______________ ADDENDUM #_______ Dated_______________
ADDENDUM #_______ Dated_______________ ADDENDUM #_______ Dated_______________
Bids shall be officially signed in accordance with the Instructions to Bidders, using the applicable portion of the "Signature Pages".
Architect’s Project No: 630874
City of Staunton, VA 000301-5
J&DR Courts Facility General Construction Bid Form
Moseley Architects Project No: 630874
SIGNATURES
IN WITNESS WHEREOF, the undersigned has caused this Bid to be executed as of the day and year indicated on the first page hereof.
For Individual Bidder
Name of Bidder (Printed)
______________________________ By: __________________________________________
Witness (Signature of Individual)
Trading and doing business as * ______
Business Address
*If a fictitious or trade name is employed in the conduct of business, insert name here:
Next, complete, by deletion as appropriate, the following statement:
Foregoing fictitious or trade name (has) (has not) been registered by the individual proprietorship under
Virginia Law.
Architect’s Project No: 630874
City of Staunton, VA 000301-6
J&DR Courts Facility General Construction Bid Form
Moseley Architects Project No: 630874
For Partnership Bidder
(Name of Partnership)
Name of General Partner (Printed)
_____________________________ By: _____
Witness (Signature of General Partner)
The Partners constituting the Partnership herein named are:
Partner Address
[Add additional lines for the names and addresses of additional Partners, if there are more than four
Partners in the Partnership, by attaching an additional page or pages to this Bid.]
*If a fictitious or trade name is employed by the Partnership in conduct of its business, insert name here:
Next, complete, by deletion as appropriate, the following statement:
Foregoing fictitious or trade name (has) (has not) been registered by the partnership under Virginia Law.
Architect’s Project No: 630874
City of Staunton, VA 000301-7
J&DR Courts Facility General Construction Bid Form
Moseley Architects Project No: 630874
For Corporate Bidder
(Name of Corporation)
By:_______________________________ Attest:
Signature of President, Vice President, Signature of Secretary, Assistant Secretary, or other authorized representative * Treasurer, Assistant Treasurer or other authorized representative **
(CORPORATE SEAL)
* If a representative other than the President or a Vice President of the Corporation signs this Bid on its behalf, then attach a valid corporate resolution or other appropriate proof, dated prior to or as of the date of the Bid, evidencing authority to execute this Bid on behalf of the Corporation.
** If a representative other than the Secretary, an Assistant Secretary, the Treasurer or an Assistant
Treasurer attests to the signature of the corporate representative, then attach a valid corporate resolution or other appropriate proof, dated prior to or as of the date of the Bid, evidencing authority to attest to the execution of this Bid on behalf of the Corporation.
(1) Complete the following statement:
The Corporation has been organized and is existing under laws of the State/Commonwealth of
(2) If the Corporation has been organized under laws of a State other than those of the Commonwealth of Virginia, complete, by deletion as appropriate, the following statement:
The Corporation (has) (has not) been granted a certificate of authority to do business in the
Commonwealth of Virginia under applicable laws.
(3) If the Corporation has been organized under laws other than those of the Commonwealth of Virginia and has NOT been granted a certificate of authority, complete, by deletion as appropriate, the following statement:
The Corporation (has) (has not) applied for a certificate of authority to do business in the Commonwealth of Virginia and (has) (has not) attached a copy of the pending application to this Bid.
Architect’s Project No: 630874
City of Staunton, VA 000301-8
J&DR Courts Facility General Construction Bid Form
Moseley Architects Project No: 630874
For Limited Liability Company (LLC) Bidder
[Name of Contractor]
(Print Name of Limited Liability Company)
Attest:___________________________ By: ________________________________________
Signature of an authorized representative* Signature of an authorized representative**
* The individual attesting verifies and represents that the person whose signature is affixed to this Bid on behalf of the Limited Liability Company (LLC) is duly authorized in accordance with the representations hereafter set forth.
** Check the box which applies to this Bid:
□ The Certificate of Organization or operating agreement provides that the LLC is to be managed by managers, and this Bid has been executed by a Manager fully authorized by the Certificate, by the
Operating Agreement and by Resolutions of the LLC. Copies of the relevant documents are provided with the Bid or can be provided upon request within three (3) working days.
□ The Certificate of Organization and operating agreement does not provide that LLC is to be managed by managers, and this Bid has been executed by a Member fully authorized by the Certificate, by the
Operating Agreement and by Resolutions of the LLC. Copies of the relevant documents are provided with the Bid or can be provided upon request within three (3) working days.
□ This Bid has been executed by a representative of the LLC who is not a Manager or a Member of the
LLC, and instead who holds the office of ______________________ (insert title), and the execution of this Bid is fully authorized by the Certificate, by the Operating Agreement and by Resolutions of the
LLC. Copies of the relevant documents are provided with the Bid or can be provided upon request within three (3) working days.
The Bidder and the individuals signing and attesting to the execution of this document further represent that (1) execution of the Bid is carrying on business in the usual way; (2) the LLC authorizes the execution of this Bid even if execution and submission of this Bid is not carrying on business in the usual way for the
LLC; and (3) to the best of the individuals’ information and belief, the Owner has no knowledge of the
Member’s or the Manager’s lack of actual authority, or of any applicable and relevant restriction on his or her authority.
Architect’s Project No: 630874
City of Staunton, VA 000301-9
J&DR Courts Facility General Construction Bid Form
Complete the following statement:
The LLC has been organized and is existing under laws of the State/Commonwealth of:
If the LLC has been organized under laws of a State other than those of the Commonwealth of Virginia, complete, by deletion as appropriate, the following statement:
The LLC (has) (has not) been granted a certificate of authority to do business in the Commonwealth of
Virginia under applicable laws.
If the LLC has been organized under laws other than those of the Commonwealth of Virginia and has NOT been granted a certificate of authority, complete, by deletion as appropriate, the following statement:
The LLC (has) (has not) applied for a certificate of authority to do business in the Commonwealth of
Virginia and (has) (has not) attached a copy of the pending application to this Bid.
Architect’s Project No: 630874
GENERAL SITEWORK REQUIREMENTS 01 02 00 - Page 1 of 3
GENERA
SECTION 01 02 00 – GENERAL SITEWORK REQUIREMENTS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the contract, including General and Supplemental Conditions and other Division 1 Specification Sections, apply to this Section.
1.2 SITEWORK LAYOUT
A. Monuments and Benchmarks
1. Maintain all monuments, property corners, benchmarks and other reference points.
2. If these are disturbed or destroyed during construction operations, have them replaced by a surveyor licensed in the Commonwealth of Virginia. This replacement shall be at no additional expense to the Contract.
B. Laying out the Work.
1. Locate all existing benchmarks and other reference points.
2. Protect these points throughout construction.
3. Layout work utilizing these reference points.
C. As-Built Drawings
1. Maintain a record of the as-built locations of all underground utilities and piping.
2. Maintain a record of any as-built variations of the work.
3. As-built Drawings shall be prepared and certified by a Land Surveyor registered in the
Commonwealth of Virginia and in accordance with the City of Staunton’s As-Built requirements and submitted to them for approval.
4. Submit these as-built drawings at Project Closeout.
1.3 EASEMENTS
A. Restore all off-site easements to the condition existing prior to the start of work.
1.4 MAINTENANCE OF TRAFFIC
A. Maintain vehicular and pedestrian traffic across the frontage of this project. Comply with all applicable safety requirements.
kgaray Text Box
(*AD-03)
kgaray Text Box
(*AD-03)
Architect’s Project No: 630874
GENERAL SITEWORK REQUIREMENTS 01 02 00 - Page 2 of 3
GENERA
1.5 SUBMITTALS
A. For those submittals, close-out documents and O&M manuals requiring review by the engineer’s consultants, contractor shall ship such documents to the engineer.
1.6 CORRELATION OF CONSTRUCTION DOCUMENTS
A. Review construction documents thoroughly prior to the start of construction.
B. Report any conflict or discrepancy discovered in the Construction Documents to the Engineer prior to the start of construction.
C. Report any conflict or discrepancy discovered between the Construction Documents and state and local governmental regulations to the Engineer prior to the start of construction.
1.7 PROJECT CONDITIONS
A. The conditions existing at the time of inspection for bidding purposes will be maintained by the Owner to the extent practical. However, minor variations may occur due to Owner’s removal and salvage operations prior to the start of demolition work.
B. The location of existing underground utilities indicated is approximate only. Field locate all existing underground utilities in the area of work, regardless of whether or not they are indicated. Call “Miss Utility” prior to the start of demolition work for assistance in the location of existing underground utilities.
C. Should charted, uncharted or incorrectly charted utilities be encountered during demolition, contact the engineer immediately for instructions. Cooperate with Owner and utility companies to keep services and facilities in operation.
PART 2 - PRODUCTS (Not Applicable)
PART 3 - EXECUTION
3.1 PROJECT CLEAN UP
A. Clean site as construction progresses. Do not allow trash or other waste materials to accumulate.
B. Prior to requesting the punch-list inspection, clean the site to the following requirements:
1. Power wash all walks and pavements.
2. The remainder of the site shall be broom clean.
3. Remove all trash and debris.
kgaray
Architect’s Project No: 630874
GENERAL SITEWORK REQUIREMENTS 01 02 00 - Page 3 of 3
GENERA
3.2 EXISTING FACILITIES
A. Preserve existing signs, markers, guardrails and fences in their original condition unless written permission is obtained for their removal and replacement.
B. Replace damaged items at no additional cost to the Contract.
END OF SECTION
kgaray
Architect's Project No.: 630874
Allowances (*AD-03) 012100 - 1
SECTION 012100
ALLOWANCES (*AD-03)
PART 1 GENERAL
1.01 SUBMITTALS
A. Allowance Proposal: Submit initial proposal for purchase of products and materials, on Change Order form.
B. Supporting Documentation:
1. Products and Material: Provide invoices and other documents as required, for products and materials indicating quantities, prices, taxes, delivery fees, and other costs.
2. Labor and Installation: Provide time sheets and other documents as required, indicating all on-site Subcontractor costs, including hours worked, quantity or amount of product/material installed, hourly wages, and…
This is the start of the file's text. The full file is on GovTribe.