2024_03_01_Staunton-JDR_Drawings_BID_Part2.pdf
PDF 36 MB Posted
- Attached to
- Bid #C00124 - J&DR COURTS FACILITY
- Solicitation number
- 60532
- Issued by
- Martinsville City, Virginia
About this file
This document is a set of drawings for the bid of the J&DR Courts Facility construction project in the City of Staunton, Virginia. The project involves the construction of a new courthouse facility for the Juvenile and Domestic Relations (J&DR) Courts. The drawings provide detailed architectural, structural, mechanical, and electrical plans and specifications for the construction of the new building. The bid is identified as Bid #C00124 and is being issued by the City of Staunton. The bid requires the submission of construction proposals by interested contractors, with a deadline for responses. The contract will be awarded to the successful bidder, who will be responsible for the completion of the construction project.
The pricing and other commercial terms are not included in this set of drawings, as they would typically be outlined in the overall bid package or contract documents. The drawings provide the technical specifications and design details required for contractors to prepare their bids. The project is being funded through state and local funding sources, with specific amounts and sources not detailed in this document. There is no information provided regarding any set-asides or incumbent contractors for this project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DADA
SECURITY ELECTRONICS
DPS
M
PLC
NETWORK
SWITCH
NETWORK
SWITCH (POE)
B A
NETWORK
VIDEO
MANAGEMENT
SYSTEM
AUDIO
WATER CONTROL SOLENOID
VALVES(COORDINATE WITH DIV 22)
LIGHTING CONTROL RELAY
PANEL (COORDINATE WITH DIV
26)
PB
REPRESENTED BY n
APPLIES TO SINGLE LINE DIAGRAM
KEYNOTES
1. EXTERIOR POLE MOUNTED CAMERAS/INTERCOM SHALL USE FIBER OPTIC CABLE FOR
VIDEO, AUDIO, AND DATA TRANSMISSION.
2. ALL FIBER OPTIC CABLING FOR SECURITY NETWORK, CATEGORY 6 CABLING FOR
CAMERAS, AND SECURITY SERVERS/WORKSTATIONS SHALL BE INSTALLED,
TERMINATED, AND TESTED PRIOR TO USE. PROVIDE FIBER BACKBONE FOR NETWORK
INFRASTRUCTURE BETWEEN BUILDINGS.
3. PROVIDE SMS SERVER IN SECURITY ELECTRONICS ROOM 0016. CONNECT TO KVM IN
RACK FOR CCTV SERVERS.
4. ALL POWER TO SECURITY HEADEND EQUIPMENT AND ASSOCIATED FIELD
COMPONENTS SHALL BE CONNECTED TO EMERGENCY / GENERATOR POWER
(THROUGH AN SCSC PROVIDED UPS).
5. PROVIDE A SECOND NETWORK CARD ON ALL CCTV SERVERS AND SMS/ACS SERVER
FOR USE BY THE COUNTY.
6. PROVIDE CAPABILITY TO CUT OFF WATER AND LIGHTING VIA TOUCHSCREEN.
7. PROVIDE AN ALARM DIALER TO SEND ALL SECURITY ALARMS TO 911 FOR AFTER HOURS
WHEN TOUCHSCREENS ARE NOT LOGGED IN.
SECURITY MGMT
SERVER (SMS)
NETWORK
VIDEO STORAGE
CRCARD
ACCESS
RX
A. SECURITY CONTROL SYSTEM CABLING AND WIRING INDICATED IS DIAGRAMMATIC
ONLY. IT IS INTENDED TO SHOW PROPOSED LOCATIONS OF MAJOR COMPONENTS OF
THE SECURITY CONTROL SYSTEM AND THEIR INTERCONNECTION.
B. NO CONDUIT SIZES OR QUANTITIES NOR CONDUCTOR TYPES OR QUANTITIES ARE
INDICATED. THE SECURITY CONTROL SYSTEM CONTRACTOR'S (SCSC) INDIVIDUAL
CONTROL SOLUTION WILL DETERMINE THE EXACT CONDUIT AND CONDUCTOR
REQUIREMENTS. REFER TO DRAWINGS FOR QUANTITIES AND LOCATIONS OF
INDIVIDUAL SECURITY CONTROL SYSTEM EQUIPMENT AND DEVICES. REFER TO
DIVISION 26 ELECTRICAL FOR POWER.
ONE-LINE DIAGRAM GENERAL NOTES
CONTROL ROOM
A
24" TOUCHSCREEN
CONTROL PANEL
CPU
120VAC
EMERGENCY
.UPSCPU
120VAC
EMERGENCY
.UPS
24"
VMS
MONITOR
24"
CALL-UP
MONITOR
LEVEL 1
LEVEL 2
LEVEL 1
LEVEL 2
EL
DADA
SECURITY ELECTRONICS
DPS
PLC
NETWORK
SWITCH (POE)
B A
CR
CARD
ACCESS
EL
GB
RX
SECURITY DESK
B
24" TOUCHSCREEN
CONTROL PANEL
CPU
120VAC
EMERGENCY
.UPSCPU
120VAC
EMERGENCY
.UPS
24"
VMS
MONITOR
24"
CALL-UP
MONITOR
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
ANTHONY J. BELL III
Lic. No. 009147
M O S E L E Y A R C H
IT
E C T S .C O M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
F
A X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/1
/2
:1
:0
A
M
SECURITY
ELECTRONICS ONE
LINE DIAGRAMS
W E
S T
B E
V E
R L
E Y
S T
R E
E T
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
C
IT
Y O
F S
T A
U N
T O
N
V A
SE4.0
630874
MARCH 1, 2024
SECURITY TYPICAL ONE-LINE DIAGRAM
REVISIONS
DATE DESCRIPTION
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
ANTHONY J. BELL III
Lic. No. 009147
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
ANTHONY J. BELL III
Lic. No. 009147
UP
UP
F E C
FEC
FEB
F E B
FEBF
E C
F E C
FEC
F E C
UP
UP
UP
WOMEN'S
TOILET
WAITING
VISITOR
WAITING
DOC REVIEW
OPEN OFFICE
CUSTOMER
SERVICE
COUNTER
STAFF TLT
ATTNY/WITNESS
VEST
ATTNY/WITNESS/REMOTE
JAN
BLUE RIDGE
COURT SRVCS
COMM ATTNY
CORR
INV
INV
SALLY PORT
HOLDING
HOLDING
SALLY PORT
HOLDING
SECURE CORR
SALLY PORT
CORR
INACTIVE
FILES
WORKROOM
J&DR CLERK
CONFERENCE
TOILET
CLOSET
SECURE
STORAGE
STORAGE
SHARED
BREAK
WELLNESS
ROOM
JUDGE
CHAMBER
RAMP
A/V
MECH
ELEC
SALLY PORT
STAFF TOILET
CONTROL
ROOM
HOLD TOILET
VEHICLE
SALLY PORT
ELEVATOR
FILES
STAFF TLT
SECURITY
DESK
MEN'S TOILET
J&DR
COURTROOM
KITCHENETTE
WAITING
FAMILY TLT
MDF
MAIN ELEC
VEST
OPEN STAIR
S01-01 STAIR 2
S02-01
STAIR 3
S03-01 STAFF ELEV
LOBBY
CORR
CORR
COUNTER
SECURE
ELEVATOR
R E F
A7.2.1
A8.2.1 6
A7.1.2
A7.1.2 5
A8.1.2
A8.1.1
A8.1.1 9
A8.1.1 11
A8.1.112
A8.1.18
A8.1.15
A8.1.0
A7.1.2
A8.1.2
A8.1.1 7
SECURITY
ELECTRONICS
A8.1.1 13
A8.2.1
A8.2.1 3
A8.1.1
A8.2.1
A7.1.2
4 3
A8.1.0
A8.1.2
A3.0.4
A. FURNITURE AND EQUIPMENT ARE NOT PART OF THE CONSTRUCTION CONTRACT
AND ARE SHOWN AS A REFERENCE FOR COORDINATION PURPOSES ONLY.
FURNITURE GENERAL NOTE
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
ANTHONY J. BELL III
Lic. No. 009147
M O S E L E Y A R C H
IT
E C T S .C O M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/1
/2
:3
:0
A
M
FIRST FLOOR
FURNITURE PLAN
W E
S T
B E
V E
R L
E Y
S T
R E
E T
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
C
IT
Y O
F S
T A
U N
T O
N
V A
FE2.1
630874
MARCH 1, 2024
1/8" = 1'-0"
FIRST FLOOR FURNITURE PLAN
REVISIONS
DATE DESCRIPTION
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
ANTHONY J. BELL III
Lic. No. 009147
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
UP
F E C
F E C
FEC
F E C
FEC
UP
FEC
WORKROOM
CUSTOMER
TLT
VISITOR
WAITING
OFFICE
SPECIALIST
INTAKE
OFFICER
FILES
SUPERVISOR
DIRECTOR
STAFF TLT
PROBATION
OFFICER
CONFERENCE
ROOM
KITCHENETTE
STAFF TLT
217COFFEE
SERVER ROOM
WAITING
WAITING
HOLDING
SALLYPORT
SECURE CORR
SALLYPORT
HOLDING
SALLYPORT
HOLDING
INV
268A
INV
HOLDING
BENCH
ATTNY/WITNESS/REMOTE
CORR
PUBLIC
DEFENDER/ATTORNEY
MEDIATOR
JAN
VEST
ATTNY/WITNESS
JUVENILE AND
DOMESTIC
RELATIONS
COURTROOM
A/V
RAMP
231TLT
STAIR 3
STAFF
ELEVATOR
DEPUTY
SHERIFF
SERGEANT
CHIEF DEPUTY
SHERIFF
CONFERENCE
ROOM
OPEN OFFICE
JUDGES
CHAMBER
CLOSET
CONFERENCE
CORRIDOR
STAFF TLT
SECURE
STORAGE
INTERN
WOMEN'S
TOILET
MEN'S TOILET
CONFERENCE
ROOM
FAMILY TLT
STAFF TLT
ELEC
CORRIDOR
CORRIDOR
LOBBY
KITCHENETTE
IDF
CORR
STAIR 2
S02-02
A7.2.2
A8.1.1 14
A8.1.2
A8.1.2
A8.1.1
A8.1.1
A8.1.0
A8.1.0
A8.1.0
A8.1.1 17
SECURITY
ELECTRONICS
STAIR 4
S04-02
A. FURNITURE AND EQUIPMENT ARE NOT PART OF THE CONSTRUCTION CONTRACT
AND ARE SHOWN AS A REFERENCE FOR COORDINATION PURPOSES ONLY.
FURNITURE GENERAL NOTE
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
ANTHONY J. BELL III
Lic. No. 009147
M O S E L E Y A R C H
IT
E C T S .C O M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/1
/2
:3
:0
A
M
SECOND FLOOR
FURNITURE PLAN
W E
S T
B E
V E
R L
E Y
S T
R E
E T
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
C
IT
Y O
F S
T A
U N
T O
N
V A
FE2.2
630874
MARCH 1, 2024
1/8" = 1'-0"
SECOND FLOOR FURNITURE PLAN
REVISIONS
DATE DESCRIPTION
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
ANTHONY J. BELL III
Lic. No. 009147
C
AO
M
M O N
W E
A LTH OF
V
I R G I N I
A TRCH I T EC
1. CLASSIFICATION OF BUILDING
RISK CATEGORY (IBC TABLE 1604.5) III
2. FLOOR LIVE LOADS UNIFORM CONCENTRATED
OFFICES 50 PSF 2000 LB
PARTITION ALLOWANCE 15 PSF WHERE UNIFORM LIVE LOAD IS
LESS THAN 80 PSF
LOBBIES, COURTROOMS, STAIRS AND CORRIDORS 100 PSF 2000 LB
LIGHT STORAGE 125 PSF
MECHANICAL ROOMS 150 PSF
CELLS 40 PSF
HANDRAILS AND GUARDS 50 PLF 200 LB
LOADS ARE NOT CONCURRENT AND ARE TO BE APPLIED IN ANY DIRECTION
CONCENTRATED LOAD APPLIED OVER 2'-6" x 2'-6" AREA.
REDUCTION OF FLOOR LIVE LOAD HAS NOT BEEN UTILIZED.
3. ROOF LIVE LOADS
MINIMUM ROOF LIVE LOAD 20 PSF 300 LB
CONCENTRATED LOAD APPLIED OVER 2'-6" x 2'-6" AREA.
REDUCTION OF MINIMUM ROOF LIVE LOAD HAS NOT BEEN UTILIZED.
4. SUPERIMPOSED DEAD LOADS
ROOF 28 PSF
ALL FRAMED FLOORS, U.N.O. 13 PSF
PHOTOVOLTAIC PANEL SYSTEMS 15 PSF
5. ROOF SNOW LOAD
GROUND SNOW LOAD (Pg) 43 PSF IMPORTANCE FACTOR (ls) 1.1 EXPOSURE FACTOR (Ce) 1.0 THERMAL FACTOR (Ct) 1.0 FLAT ROOF SNOW LOAD (Pf = 0.7 x Ce x Ct x ls x Pg) 33 PSF MINIMUM Pf FOR Pg > 20 PSF
Pf min = 20 x I 22 PSF
SNOW DRIFTING LOADS PER ASCE 7
6. WIND DESIGN DATA
DESIGN WIND SPEED 120 MPH
EXPOSURE B
INTERNAL PRESSURE COEFFICIENT (GCpi) ±0.18 (ENCLOSED)
COMPONENTS AND CLADDING WIND PRESSURE REFER TO TABLE BELOW (PER IBC & ASCE7)
7. SEISMIC DESIGN DATA
SEISMIC DESIGN CATEGORY B
SEISMIC IMPORTANCE FACTOR (le) 1.25
SITE CLASS D
MAPPED SPECTRAL RESPONSE ACCELERATIONS
(Ss) 0.15 (S1) 0.06
DESIGN SPECTRAL RESPONSE ACCELERATIONS
(Sds) 0.16 (Sd1) 0.09
BASIC SEISMIC FORCE RESISTING SYSTEM: B. BUILDING FRAME SYSTEM
INTERMEDIATE REINFORCED MASONRY SHEAR WALLS
ALL STEEL SYSTEMS ARE: H. SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC
RESISTANCE.
RESPONSE MODIFICATION COEFFICIENT (R) 3.0
SYSTEM OVERSTRENGTH FACTOR 2.5
DEFLECTION AMPLIFICATION FACTOR 3.0
SEISMIC RESPONSE COEFFICIENT (Cs) 0.07 DESIGN BASE SHEAR (V = Cs x W) 0.07W
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE
1. FOUNDATIONS ARE DESIGNED TO BEAR ON ORIGINAL UNDISTURBED SOIL OR CONTROLLED COMPACTED FILL WITH AN ALLOWABLE BEARING CAPACITY OF 2,000 PSF, IN ACCORDANCE WITH THE GEOTECHNICAL ENGINEERING REPORT PREPARED BY TIMMONS DATED 12-07-23. REFER TO THIS REPORT FOR UNDER CUT OF SOILS BELOW BUILDING PAD AND FOR REPLACEMENT WITH IMPORTED GRANULAR FILL MATERIALS.
2. THE GEOTECHNICAL ENGINEER FOR THE OWNERS TESTING AGENCY SHALL VERIFY BEARING CAPACITY
AND SUITABILITY OF SUBGRADE PRIOR TO PLACING FOUNDATIONS AND GRADE SLABS.
3. SELECT AND PLACE CONTROLLED COMPACTED FILL UNDER DIRECT SUPERVISION OF THE GEOTECHNICAL
ENGINEER FOR THE OWNERS TESTING AGENCY.
4. FOOTING STEPS FOR UNDERSLAB UTILITIES INDICATED ON FOUNDATION PLANS SHALL BE CONSIDERED
APPROXIMATE. COORDINATE FOOTINGS WITH ACTUAL LOCATION, SIZE AND INVERT OF ALL
UNDERGROUND PIPE (AND CONDUIT). REFER TO "FOOTING STEP" DETAIL TO STEP WALL FOOTING DOWN TO ALLOW UNDERSLAB PIPING TO PASS ABOVE THE FOOTING. ALTERNATELY, REFER TO "FOOTING SLEEVE" AND "PIPE TRENCH BACKFILL AT FOOTING" DETAILS TO ALLOW UNDERSLAB PIPING TO PASS
BELOW THE TOP OF THE WALL FOOTING.
5. AVOID INFLUENCE OF PIPE TRENCH PARALLEL TO WALL FOOTING AND / OR ADJACENT TO COLUMN
FOOTING. REFER TO "FOOTING EXCAVATION LIMITS".
6. PROTECT FOOTINGS AND GRADE SLABS FROM FROST HEAVE UNTIL BUILDING IS PERMANENTLY
ENCLOSED.
7. BRACE WALLS PLUMB WHICH ARE SUBJECTED TO UNBALANCED BACKFILL UNTIL PERMANENTLY
STABILIZED BY STRUCTURE.
1. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE FOLLOWING AISC DOCUMENTS:
AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS"
AISC 303 "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES"
RCSC'S "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS"
2. STRUCTURAL STEEL SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS:
WIDE FLANGE SHAPES AND ANGLES ASTM A992 (FY=50 KSI)
MISCELLANEOUS SHAPES, PLATES & BARS (TO 8" THICK) ASTM A36 (FY=36 KSI)
HOLLOW STRUCTURAL SECTIONS (HSS)
SQUARE & RECTANGLE ASTM A500, GRADE C (FY=50 KSI)
ROUND ASTM A500 GRADE C (FY=46 KSI)
HIGH STRENGTH BOLTS (CONVENTIONAL) ASTM F3125 GRADE A325 OR A490 (TYPE 1)
WASHERS ASTM F436 (FLAT AND BEVELED)
HEAVY HEX NUTS ASTM A563
TWIST OFF TENSION CONTROL BOLTS ASTM F3125 GRADE F1852 OR F2280 (TYPE 1)
COMPRESSIBLE-WASHER DIRECT-TENSION INDICATORS ASTM F959 (TYPE 325 OR 490)
ANCHOR RODS ASTM F1554, GRADE 55 INCLUDE SUPPLEMENT S1
WELDING ELECTRODES E70 (LOW HYDROGEN)
HEADED SHEAR STUDS AWS D1.1 CLAUSE 9, TYPE B (FY=51 KSI)
THREADED ROD ASTM A36
3. UNLESS NOTED OTHERWISE, CONNECTIONS SHALL BE DESIGNED IN ACCORDANCE WITH AISC MANUAL OF STEEL CONSTRUCTION, AS SIMPLE CONNECTIONS USING ALLOWABLE STRENGTH DESIGN (ASD). CONNECTIONS FOR NON- COMPOSITE BEAMS SHALL BE DESIGNED FOR THE UNIFORM LOAD CAPACITY INDICATED IN THE ALLOWABLE UNIFORM LOAD TABLES, PART 3, OF THE AISC MANUAL. CONNECTIONS FOR COMPOSITE STEEL BEAMS SHALL BE DESIGNED FOR
THE REACTIONS INDICATED ON THE PLANS.
4. UNLESS NOTED OTHERWISE, THE TOP OF ALL STEEL COLUMNS SHALL HAVE A STEEL CAP PLATE WITH A MINIMUM THICKNESS OF 1/2". CAP PLATE DIMENSIONS SHALL MATCH COLUMN WIDTH AND DEPTH MINIMUM. WHERE JOISTS
BEAR ON COLUMN, COORDINATE BEARING REQUIREMENTS WITH JOIST MANUFACTURER.
5. BOLTED JOINTS SHALL BE "SNUG TIGHTENED", UNLESS OTHERWISE INDICATED.
6. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING CODE - STEEL".
7. WHERE STRUCTURAL STEEL IS EXPOSED BELOW GRADE, PROVIDE MINIMUM 3" CONCRETE COVER OR COAT WITH
BITUMINOUS MASTIC.
8. STRUCTURAL STEEL EXPOSED TO WEATHER IN THE FINISHED WORK SHALL BE HOT DIPPED GALVANIZED IN
ACCORDANCE WITH ASTM A123, UNLESS NOTED OTHERWISE.
1. ALL STEEL DECK WORK SHALL CONFORM TO THE LATEST EDITION OF THE STEEL DECK INSTITUTE (SDI) "DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS", AND AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS".
2. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE - SHEET STEEL".
3. PERMANENT LOADS SHALL NOT BE SUSPENDED FROM STEEL ROOF DECK UNLESS APPROVED BY ENGINEER
OF RECORD.
4. STEEL DECK UP TO 2" DEEP SHALL BE INSTALLED WITH A MINIMUM OF 3 CONTINUOUS SPANS, UNLESS NOTED. STEEL DECK SHALL BE INSTALLED WITH A MINIMUM OF 2 CONTINUOUS SPANS, UNLESS NOTED OTHERWISE. ANY LOCATIONS NOT MEETING THESE CONDITIONS SHALL BE SPECIFICALLY IDENTIFIED ON THE
STEEL DECK SHOP DRAWINGS.
5. REFER TO "STEEL DECK SCHEDULE" FOR DECK TYPES AND FASTENING REQUIREMENTS.
1. ALL MASONRY WORK SHALL CONFORM TO THE REQUIREMENTS OF TMS 402 "BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES WITH COMMENTARY" AND TMS 602
"SPECIFICATIONS FOR MASONRY STRUCTURES WITH COMMENTARY".
2. NET AREA COMPRESSIVE STRENGTH OF CONCRETE MASONRY(F'm), SHALL BE 2000 PSI, DETERMINED IN ACCORDANCE WITH THE UNIT STRENGTH METHOD PER TMS 602, UNLESS NOTED
OTHERWISE.
3. CONCRETE MASONRY UNITS (CMU) SHALL CONFORM TO ASTM C90, AND SHALL BE MADE WITH
LIGHTWEIGHT AGGREGATE.
4. MORTAR FOR CMU SHALL CONFORM TO ASTM C270, TYPE S, AND PROVIDE TYPE M MORTOR AT
SECURITY WALLS.
5. GROUT SHALL CONFORM TO ASTM C476 AND SHALL BE PROPORTIONED TO OBTAIN MINIMUM
ULTIMATE 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI.
6. PLACE GROUT IN ACCORDANCE WITH TMS 402. ALLOW A MINIMUM OF 24 HOURS FOR MASONRY
TO SET PRIOR TO PLACING GROUT. HIGH LIFT GROUTING IS PROHIBITED.
7. FILL COLLAR JOINTS OF COMPOSITE WALLS SOLID WITH MORTAR AS THE WALLS PROGRESS.
BOND WYTHES OF COMPOSITE WALLS TOGETHER USING HORIZONTAL JOINT REINFORCING @ 16"
ON CENTER, UNLESS NOTED OTHERWISE.
8. PROVIDE VERTICAL REINFORCING STEEL OF SIZE AND SPACING INDICATED. LAP SPLICE LENGTHS
SHALL BE AS FOLLOWS:
#4 BAR AND SMALLER 26 INCHES
#5 BAR 34 INCHES
#6 BAR 38 INCHES
9. PROVIDE POSITIONERS TO HOLD VERTICAL WALL REINFORCING STEEL IN PROPER ALIGNMENT.
10. REINFORCING STEEL SHALL COMPLY WITH ASTM A615, GRADE 60.
11. DO NOT PLACE CONDUIT IN CELLS CONTAINING STRUCTURAL REINFORCING.
12. NO SWITCHES OR BOXES WITHIN 20 INCHES OF A DOOR JAMB.
13. REINFORCING AND CONDUIT SHALL BE SEPARATED A MINIMUM OF 1 INCH WHEN THEY
INADVERTENTLY OCCUR WITHIN THE SAME CMU CELL.
14. MASONRY WALLS OF HOLLOW UNITS WHICH CHANGE THICKNESS SHALL HAVE A CONTINUOUS
GROUT FILLED COURSE BELOW THE TRANSITION. IF WALL THICKNESS IS GREATER ABOVE THE
TRANSITION, THE COURSE ABOVE THE TRANSITION SHALL ALSO BE GROUTED SOLID.
15. FILL CMU CELLS WITH GROUT FROM TOP OF FOOTING TO TOP OF SLAB-ON-GRADE ELEVATION.
16. MASONRY WALL CONTROL JOINTS ARE NOT INDICATED ON THE STRUCTURAL DRAWINGS. REFER
TO ARCHITECTURAL DRAWINGS FOR JOINT LOCATIONS AND DETAILS. COORDINATE JOINT
LOCATIONS TO AVOID BEAM BEARING LOCATIONS AND SHEAR WALLS. DO NOT BREAK BOND BEAM
REINFORCEMENT AT CONTROL JOINTS.
17. QUALITY ASSURANCE LEVEL FOR THIS STRUCTURE SHALL BE LEVEL 3.
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE VIRGINIA UNIFORM STATEWIDE BUILDING CODE (USBC), 2018 EDITION.
1. THE STRUCTURAL DRAWINGS ARE INTENDED TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL
DRAWINGS AND THE DRAWINGS OF THE OTHER ENGINEERING DISCIPLINES.
2. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. IN THE CASE OF A CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE BETTER QUANTITY. IN THE CASE OF A CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE GREATER QUANTITY OF
WORK.
3. VERIFY AND COORDINATE MECHANICAL UNIT SUPPORTS AND OPENINGS WITH EQUIPMENT PURCHASED FOR THE PROJECT. COORDINATE REQUIREMENTS FOR SLEEVES, HANGERS, INSERTS, ANCHORS AND ALL OTHER ITEMS
TO BE SET IN STRUCTURAL WORK.
4. SPECIAL INSPECTIONS ARE REQUIRED BY THE USBC (SECTION 1704).
REFER TO THE STATEMENT OF SPECIAL INSPECTIONS PREPARED FOR THIS PROJECT AND THE PROJECT
SPECIFICATIONS FOR SPECIFIC INSPECTION REQUIREMENTS.
REFER TO SPECIFICATION SECTION 014000 FOR GENERAL INSPECTION REQUIREMENTS. SPECIAL INSPECTOR SHALL SUBMIT INSPECTION REPORTS IN COMPLIANCE WITH IBC SECTION 1704.2.4. USE OF "GENERAL
CONFORMANCE" OR "GENERAL ACCORDANCE" IS UNACCEPTABLE.
6. CONTRACTOR SHALL CONDUCT PRE-INSTALL MEETINGS ON PROJECT SITE PRIOR TO COMMENCEMENT OF WORK. REFER TO PROJECT SPECIFICATIONS FOR SPECIFIC REQUIREMENTS. GENERAL CONTRACTOR WILL CONDUCT THE MEETING AND SHALL BE RESPONSIBLE FOR THE ATTENDANCE OF ALL REQUIRED TRADES
AND SUBCONTRACTORS INCLUDING THE SPECIAL INSPECTOR.
SECTION AND DETAIL 1
S2.1 S4.2
S2.2 S2.3
SECTION OR DETAIL NUMBER
DRAWING NUMBER WHERE SECTION OR DETAIL IS DRAWN
DRAWING NUMBER WHERE SECTION OR DETAIL IS CUT
ADDITIONAL DRAWING NUMBERS WHERE SECTION OR DETAIL IS CUT
S2.1
A
DETAIL WHERE CUT
DETAIL LETTER
DRAWING NUMBER WHERE DETAIL
IS DRAWN
S2.1
SECTION WHERE CUT
SECTION NUMBER
DRAWING NUMBER WHERE
SECTION IS DRAWN
(WHERE DRAWN)
EARTH
CAST IN PLACE CONCRETE
CLAY BRICK
SPLIT-FACE CONCRETE BLOCK
GROUT FILLED CONCRETE BLOCK
HOLLOW CONCRETE BLOCK
POROUS FILL OR GRANULAR BASE COURSE
STRUCTURAL MATERIALS LEGEND
PRECAST CONCRETE, CAST STONE
JBE (+X'-X")
BP1, BP2 ...
BP-A, BP-B ...
P-1, P-2 ...
JS
SP
-X'-X"
WP
L1, L2 ...
X.X
(+X'-X")
(J)
(SL)
JOIST BEARING ELEVATION
BEAM BEARING PLATE
COLUMN BASE PLATE
CONCRETE PIER
JOIST SUBSTITUTE
SPECIAL JOIST
WALL FOOTING STEP
TOP OF FOOTING ELEVATION
WORK POINT
TOP OF SLAB ELEVATION
LINTEL
COLUMN FOOTING
TOP OF STEEL BEAM ELEVATION
INDICATES TOP OF STRUCTURAL MEMBER SHALL
BE IN SAME PLANE AS TOP OF JOIST
INDICATES TOP OF STRUCTURAL MEMBER SHALL
BE SLOPED
CENTERLINE
WFX.X WALL FOOTING
THICKENED SLAB
* STEEL JOIST BOTTOM CHORD EXTENSION,
WELDED
STEEL BEAM MOMENT CONNECTION
(EX) EXISTING
TRANSFER FORCETF
(X'-X")
H1, H2 ...
J1, J2 ...
T-1, T-2 ...
WOOD HEADER
WOOD JOIST
TRUSS
WP1, WP2 ... WOOD POST
CMU WALL REINFORCING SIZE AND SPACING
CHANGE IN SLAB ELEVATION
#5@48"
KCS CONSTANT SHEAR JOIST
TCX TOP CHORD EXTENSION
1. ALL STRUCTURAL COLD FORMED STEEL FRAMING (CFSF) SHALL COMPLY WITH AISI'S "NORTH AMERICAN
SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS".
2. CFSF-S (STRUCTURAL): INCLUDES ALL EXTERIOR WALLS, SOFFITS, BULKHEADS, TRUSSES, RAFTERS, JOISTS AND CEILING JOISTS (IF SELF-SUPPORTING). PROVIDE ENGINEERING DESIGN OF ALL CFSF-S, AND SUBMIT DESIGN CALCULATIONS, ERECTION DRAWINGS AND DETAIL DRAWINGS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE COMMONWEALTH OF VIRGINIA. REFER TO SECTION 054000 FOR ADDITIONAL INFORMATION.
3. CFSF-NS (NON-STRUCTURAL): INCLUDES INTERIOR NON-LOAD BEARING STUD WALLS AND SUSPENDED CEILING
FRAMING SYSTEM. REFER TO SECTION 092216 FOR ADDITIONAL INFORMATION.
4. ALL FRAMING MEMBERS, BRIDGING AND ACCESSORIES SHALL BE FORMED FROM STEEL SHEET HAVING A
GALVANIZED COATING IN ACCORDANCE WITH ASTM A653.
5. ALL C - SHAPED FRAMING MEMBERS SHALL HAVE A MINIMUM FLANGE WIDTH OF 1 5/8 INCHES.
1. SYNTHETIC MACRO-FIBER MAY BE SUBSTITUTED FOR WELDED WIRE FABRIC IN SLAB-
ON-GRADE AND IN SLAB ON COMPOSITE STEEL FLOOR DECK, AND SHALL CONFORM TO
ASTM C1116, TYPE III SYNTHETIC FIBER REINFORCED CONCRETE.
DOSAGE RATES SHALL BE DETERMINED BY FIBER MANUFACTURER TO PROVIDE FRC
EQUIVALENT FLEXURAL STRENGTH (FE,3) EQUAL TO THE PERFORMANCE OF THE
REINFORCING STEEL INDICATED FOR EACH SLAB CASE. TESTING SHALL BE
PERFORMED IN ACCORDANCE WITH ASTM C1609. DOSAGE SHALL NOT BE LESS THAN
3 LB PER CU YD IN ANY CASE.
2. FIBER SHALL BE ADDED AT THE CONCRETE BATCH PLANT.
3. FIBER SHALL BE INCLUDED IN THE CONCRETE MIX DESIGNS SUBMITTED FOR REVIEW.
1. CONTROLLED LOW STRENGTH MATERIAL (CLSM), ALSO REFERRED TO AS FLOWABLE FILL, MAY BE
SUBMITTED FOR APPROVAL AS A SUBSTITUTE FOR COMPACTED FILL AT FOUNDATION UNDERCUT
LOCATIONS. THE CLSM MIXTURE SHALL BE PROPORTIONED TO PRODUCE AN UNCONFINED COMPRESSIVE
STRENGTH OF 100 PSI MINIMUM TO 300 PSI MAXIMUM.
1. ALL STEEL JOIST WORK SHALL CONFORM TO THE LATEST EDITION OF THE STEEL JOIST INSTITUTE (SJI)
STANDARD SPECIFICATIONS.
2. STEEL JOISTS SHALL BE DESIGNED USING ALLOWABLE STRENGTH DESIGN (ASD), AND SHALL BE
MANUFACTURED WITH STEEL HAVING A MINIMUM YIELD STRENGTH OF 50 KSI.
3. PROVIDE JOIST BRIDGING IN ACCORDANCE WITH SJI SPECIFICATIONS, OSHA REQUIREMENTS, AND AS
REQUIRED BY JOIST DESIGN.
4. ROOF JOISTS AND BRIDGING SHALL BE DESIGNED FOR A NET UPLIFT OF 20 PSF.
5. SPECIAL JOISTS, INDICATED "SP" ON FRAMING PLANS, SHALL BE DESIGNED FOR CRITERIA INDICATED.
6. DETAILING AND ERECTION OF OPEN WEB STEEL JOISTS SHALL COMPLY WITH OSHA REQUIREMENTS.
7. STEEL ROOF JOISTS SHALL BE PROVIDED WITH NO CAMBER.
8. DESIGN ALL JOISTS (K, KCS, LH) FOR A 500 LB CONCENTRATED LOAD (SERVICE LOAD) AT ANY ONE PANEL POINT ALONG THE JOIST, UNLESS NOTED OTHERWISE. THIS IS REFERRED TO AS AN "ADD-LOAD."
9. K-SERIES JOISTS SHALL BE DESIGNED FOR ADDITIONAL BENDING STRESSES RESULTING FROM A 200 POUND CONCENTRATED DEAD LOAD LOCATED AT ANY LOCATION ALONG TOP AND BOTTOM CHORD IN
ADDITION TO ALL OTHER LOADS. THIS IS REFERRED TO AS A "BEND CHECK."
10. KCS AND LH SERIES JOISTS SHALL BE DESIGNED FOR ADDITIONAL BENDING STRESSES RESULTING FROM A 500 POUND CONCENTRATED DEAD LOAD LOCATED AT ANY LOCATION ALONG TOP AND BOTTOM CHORD
IN ADDITION TO ALL OTHER LOADS. THIS IS REFERRED TO AS A “BEND-CHECK”.
11. REFER TO “TYPICAL CONCENTRATED LOAD ON STEEL JOIST” DETAIL FOR REQUIREMENTS REGARDING
PIPE HANGERS AND OTHER EQUIPMENT LOADS.
1. ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 318 "BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE" AND ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL
CONCRETE".
2. CONCRETE SHALL BE NORMAL WEIGHT AND SHALL OBTAIN ULTIMATE 28 DAY COMPRESSIVE STRENGTHS (F'c), AS FOLLOWS:
3. THE DURABILITY EXPOSURE CLASS IDENTIFIED BY THE ENGINEER OF RECORD, IN ACCORDANCE WITH ACI 318, FOR EACH MIX DESIGN/BUILDING ELEMENT AND EXPOSURE CLASS, IS BASED ON ASSUMED SEVERITY OF THE ANTICIPATED EXPOSURE. IF THE CONCRETE IS TO BE INSTALLED IN A LOCATION OR CONDITION THAT IS MORE SEVERE THAN THE EXPOSURE IDENTIFIED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER
OR ADJUST THE CONCRETE MIX REQUIREMENTS AS REQUIRED PER ACI 318.
A. EXPOSURE CATEGORIES:
• (F) FREEZE/THAW
• (S) SULFATE
• (W) WATER/PERMEABILITY
• (C) CORROSION PROTECTION
4. MAX W/C REFERS TO MAXIMUM WATER TO CEMENTITIOUS MATERIALS RATIO. MIXING WATER SHALL
CONFORM TO ASTM C1602.
5. TARGET AIR ENTRAINMENT, ±1.5%. ALL EXTERIOR CONCRETE SHALL BE AIR-ENTRAINED. AIR ENTRAINMENT
IS OPTIONAL FOR FOOTINGS AND GRADE BEAMS NOT EXPOSED TO FREEZING.
6. AGGREGATES TO CONFORM TO ASTM C33 FOR NORMAL WEIGHT CONCRETE.
7. CONCRETE BUILDING ELEMENTS IDENTIFIED WITH EXPOSURE CATEGORY F3 REQUIRE LIMITATIONS ON
CEMENTITIOUS MATERIALS AS FOLLOWS:
• CEMENTITIOUS MATERIAL MAX % OF TOTAL CEMENTITIOUS
MATERIALS BY MASS
• FLY ASH (ASTM C618) 25
• SLAG CEMENT (ASTM C989) 50
• SILICA FUME (ASTM C1240) 10
• TOTAL FLY ASH, OTHER POZZOLANS AND SILICA FUME 35
• TOTAL FLY ASH, OTHER POZZOLANS, SILICA FUME AND SLAG 50
8. SLABS NOT RECEIVING A HARD TROWEL FINISH MAY BE AIR-ENTRAINED. SLABS RECEIVING A HARD TROWEL FINISH SHALL NOT BE AIR-ENTRAINED AND SHALL HAVE A TOTAL AIR CONTENT OF NOT MORE THAN 3%.
9. COMBINED AGGREGATE GRADING SHALL BE AS FOLLOWS:
• FOR COARSE AGGREGATE WITH 1 1/2" NOMINAL MAXIMUM AGGREGATE SIZE, 8% TO 18% (BY WEIGHT) OF AGGREGATE SHALL BE RETAINED ON EACH SIEVE BELOW THE MAXIMUM AGGREGATE SIZE SIEVE AND
ABOVE THE #100 SIEVE.
• FOR COARSE AGGREGATE WITH 3/4" OR 1" NOMINAL MAXIMUM AGGREGATE SIZE, 8% TO 22% (BY WEIGHT) OF AGGREGATE SHALL BE RETAINED ON EACH SIEVE BELOW THE MAXIMUM AGGREGATE SIZE SIEVE AND
ABOVE THE #100 SIEVE.
10. MAX WATER SOLUBLE CHLORIDE ION CONTENT PERCENTAGE, BY WEIGHT OF CEMENT.
11. CONCRETE MIXTURE PROPORTIONS SHALL BE ESTABLISHED IN ACCORDANCE WITH ARTICLE 4.2.3 OF ACI 301 OR BY AN ALTERNATIVE METHOD ACCEPTABLE TO THE ENGINEER OF RECORD. EACH MIX DESIGN
SHALL IDENTIFY THE INTENDED LOCATION OF USE.
12. REINFORCING STEEL SHALL BE AS FOLLOWS:
• REINFORCING BARS: ASTM A615, GRADE 60, DEFORMED
• WELDED WIRE FABRIC: ASTM A1064, SHEET TYPE ONLY
• WELDABLE REINFORCING BARS: ASTM A706 LOW ALLOW STEEL REINFORCING BARS, DEFORMED
• DEFORMED BAR ANCHORS (DBA) ASTM A1064, DEFORMED
• WELDING PER AWS D1.4 STRUCTURAL WELDING CODE - REINFORCING STEEL
CONCRETE MATERIAL SCHEDULE (NOTE 11)
BUILDING
ELEMENT
DURABILITY REQUIREMENTS
CATEGORIES AND CLASSES
(NOTE 3)
(F) (S) (W) (C)
SPREAD FOOTINGS
AND WALL FOOTINGS
INTERIOR
SLABS ON GRADE
INTERIOR COLUMNS,
WALLS AND PIERS
S0 W0 C1
F0 S0 C0
F1 S0 C1
W0
W0 f'c (psi)
28 DAY
STRENGTH
MAX W/C
(NOTE 4)
AIR
ENTRAINMENT
(NOTE 5)
UNIT WEIGHT
PCF (NOTE 6)
MAX
AGGREGATE
(NOTE 7 & 9)
CEMENT
(ASTM C150)
CL %
(NOTE 10)
3,500
3,500
4,000
0.55
0.50
0.50 5.0
N/A
4.5 145
1 1/2"
3/4"
3/4"
II
I / II
I / II
0.30
0.30
0.30
EXTERIOR COLUMNS,
WALLS AND PIERS
EXTERIOR
SLABS ON GRADE
INTERIOR SLABS
ON METAL DECK
ELEVATED SLABS
AND BEAMS
GRADE BEAMS
F1
F1
F0
F0
F1
S0
S0
S0
S0
S0 W0
W0
W0
W1
W1
C1
C0
C1
C0
C1
3,500
3,500
4,000
4,000
4,000
0.55
0.50
0.50
0.50
0.55 5.0
6.0
N/A
NOTE 8
NOTE 8
3/4"
3/4"
3/4"
3/4"
3/4"
I / II
I / II
I / II
I / II
I / II
0.30
0.30
1.0
1.0
0.30
INTERIOR SLABS
ON METAL DECK
(NORMAL WT. CONC)
F0 S0 W0 C0 3,500 0.55 NOTE 8 145 3/4" I / II 1.0
F0
SPLICES IN THE REINFORCING STEEL SHALL BE ONLY AT THE LOCATIONS SHOWN
ON THE STRUCTURAL DRAWINGS. LAP SPLICES SHALL BE IN ACCORDANCE WITH
ACI 318 CHAPTER 25 AS INDICATED BELOW. TOP BAR LAPS (HORIZONTAL BARS
WITH MORE THAN 12” OF CONCRETE CAST BELOW THE BAR) SHALL BE MODIFIED
BY A MULTIPLICATION OF 1.3 TIMES THE LENGTHS LISTED IN THE TABLE BELOW.
LENGTHS INDICATED IN INCHES.
NORMAL-WEIGHT (145 PCF)
f’c (psi) #3 #4 #5 #6 #7 #8 #9
3500 20 26 33 40 58 66 74
4000 18 25 31 37 54 62 69
13. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE UNO:
A. UNFORMED SURFACE CAST AGAINST EARTH 3 IN
B. FORMED SURFACE EXPOSED TO EARTH/WEATHER 2 IN
C. FORMED SLABS AND WALLS NOT EXPOSED TO
EARTH/WEATHER FOR #11 AND SMALLER BAR 3/4 IN
D. ALL OTHER FORMED ELEMENTS NOT EXPOSED
TO EARTH/WEATHER 1 1/2 IN
14. REQUIRED COMPRESSIVE STRENGTH OF STRUCTURAL PRECAST CONCRETE SHALL BE DETERMINED BY THE PRECAST CONCRETE MANUFACTURER'S ENGINEER, WITH THE MINIMUM COMPRESSIVE STRENGTH
AS NOTED IN THE TABLE.
1. INSTALL ALL ANCHORS IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED PROCEDURES AT NOT LESS THAN THE MINIMUM EDGE DISTANCES INDICATED IN THE MANUFACTURER'S LITERATURE. SUBMIT MANUFACTURER'S
PRODUCT DATA FOR REVIEW BY THE ARCHITECT.
2. ALL ANCHORS (INCLUDING THREADED RODS, NUTS, WASHERS) SHALL BE ZINC PLATED IN ACCORDANCE WITH
ASTM B633, FOR SERVICE CONDITION SC-1.
3. SCREW ANCHORS SHALL BE ONE OF THE FOLLOWING:
SCREW-BOLT +, BY DEWALT
TITEN HD, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
KWIK HUS-EZ, BY HILTI
HOLE DIAMETER THROUGH STEEL MEMBER SHALL BE AS REQUIRED BY ANCHOR MANUFACTURER.
MINIMUM SCREW ANCHOR EMBEDMENTS SHALL BE AS FOLLOWS, UNO:
4" EMBEDMENT FOR 1/2" DIAMETER ANCHOR
5" EMBEDMENT FOR 5/8" DIAMETER ANCHOR
6" EMBEDMENT FOR 3/4" DIAMETER ANCHOR
4. ADHESIVE ANCHORS SHALL CONSIST OF THREADED ROD (ASTM A36), HEX NUT (ASTM A563), WASHER (ASTM F436), AND ADHESIVE (TYPE PER NOTES A, B OR C BELOW).
ADHESIVE DOWELS SHALL CONSIST OF DEFORMED REINFORCING BAR (ASTM A615, GRADE 60) AND ADHESIVE
(TYPE PER NOTE A BELOW)
A. "ADHESIVE ANCHORS" OR "ADHESIVE DOWELS" INSTALLED IN SOLID CONCRETE SHALL UTILIZE ONE OF
THE FOLLOWING ADHESIVE SYSTEMS, OR APPROVED EQUAL:
HYBRID (FAST CURE)
AC200+ BY DEWALT
ACRYLIC-TIE XP, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
HIT-HY 200-V3, BY HILTI
EPOXY (SLOW CURE)
PURE 110+, BY DEWALT
SET-XP, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
HIT RE 500-V3 EPOXY ADHESIVE, BY HILTI
B. "ADHESIVE ANCHORS" INSTALLED IN SOLID GROUT FILLED CMU SHALL UTILIZE ONE OF THE FOLLOWING
ADHESIVE SYSTEMS, OR APPROVED EQUAL:
HIT-HY 270, BY HILTI
AC 100+ GOLD, BY DEWALT
ACRYLIC-TIE, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
C. "SCREEN TUBE ANCHORS" INSTALLED IN HOLLOW CMU SHALL UTILIZE ONE OF THE FOLLOWING ADHESIVE
SYSTEMS, OR APPROVED EQUAL:
HIT-HY 270, BY HILTI
AC 100+ GOLD, BY DEWALT
ACRYLIC-TIE, BY SIMPSON STRONG-TIE ANCHORING SYSTEMS
BASIS OF DESIGN INCLUDES THE FOLLOWING DESIGN PARAMETERS:
(1) CRACKED CONCRETE
(2) ALLOWABLE WITH HAMMER-DRILL, HOLLOW DRILL BIT SYSTEM, AND CORE DRILLING METHODS
(3) CURRENT ICC-ES REPORT WITH APPROVAL FOR DEVELOPMENT OF BAR USING ACI PROVISIONS FOR
EMBEDMENT DEPTHS GREATER THAN 20 BAR DIAMETERS
INSTALL ANCHORS PER THE MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS, AS INCLUDED IN THE
ANCHOR PACKAGING.
OVERHEAD ADHESIVE ANCHORS SHALL BE INSTALLED USING A PISTON PLUG SYSTEM.
FOR PROJECTS MEETING IBC 2012 OR LATER, ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION IS REQUIRED FOR ALL INSTALLERS OF ADHESIVE ANCHORS IN HORIZONTAL OR UPWARDLY INCLINED ORIENTATION. THE HILTI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM (HAAICP) IS AN APPROVED
EQUIVALENT.
THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER’S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL ANCHOR PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD SHALL RECEIVE DOCUMENTED CONFIRMATION THAT ALL PERSONNEL WHO INSTALL ANCHORS ARE TRAINED
PRIOR TO THE COMMENCEMENT OF ANCHOR INSTALLATION.
EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. UNLESS NOTED ON THE DRAWINGS THAT THE BARS CAN BE CUT, THE CONTRACTOR SHALL REVIEW THE EXISTING STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION OF THE REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS BY GPR, X-RAY, CHIPPING OR OTHER
APPROVED METHODS.
1. COMPOSITE BEAMS AND GIRDERS DO NOT REQUIRE TEMPORARY SHORING FOR CONSTRUCTION
LOADS (WET CONCRETE + 20 PSF) UNO ON THE DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR
LIMITING THE CONSTRUCTION LOAD IMPOSED ON THE STRUCTURE.
2. STUDS SHALL BE 3/4" DIAMETER AND SHALL EXTEND NOT LESS THAN 1 1/2" ABOVE THE TOP OF THE STEEL DECK AND SHALL NOT HAVE LESS THAN 1/2" CONCRETE COVER ABOVE THE TOP OF STUD
AFTER WELDING.
3. THE NUMBER STUDS ON A BEAM OR BETWEEN ANY TWO CONNECTIONS ALONG A BEAM IS SHOWN
ON THE DRAWINGS. SPACING OF STUDS WITHIN THE LENGTH SHOWN SHALL BE AS UNIFORM AS
POSSIBLE.
4. NO SHOP PAINT SHALL BE APPLIED TO ANY STUDS NOR TO TOP FLANGES OR SURFACES OF
MEMBERS RECEIVING FIELD WELDED STUDS.
5. BREAK CERAMIC FERRULES (ARC SHIELDS) LOOSE AND REMOVE FROM DECK.
6. A STUD SHEAR CONNECTOR WELDED THROUGH THE METAL DECK MAY TAKE THE PLACE OF A
3/4" PLUG WELD IN ORDER TO SECURE THE DECK TO THE STEEL FRAMING. DO NOT WELD SHEAR
CONNECTORS THROUGH TWO LAYERS (LAPPED ENDS) OF DECK UNITS.
7. PLACE CONCRETE MONOLITHICALLY ON STEEL FLOOR DECK. CONSTRUCTION JOINTS MAY BE
PERMITTED ONLY AFTER APPROVAL OF THE ARCHITECT/STRUCTURAL ENGINEER.
8. CONCRETE THICKNESS SHALL BE OF A UNIFORM THICKNESS WHERE INDICATED ON METAL
FLOOR DECK.
DESIGN LOAD DATA FOUNDATIONS
STRUCTURAL STEEL
STEEL DECK
CONCRETE MASONRY (CMU)
GENERAL
LEGEND FOR SECTION AND DETAIL MARKS
PLAN LEGEND
STRUCTURAL ABBREVIATIONS
C
AO
M M O N
W
EA
LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL EN
G I
R E E03-01-2024
PAUL J. GAGNON
Lic. No. 029696
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :0
P
M
GENERAL NOTES AND
LEGENDS
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
W E
S T
B E
V E
R L
Y S
T R
E E
T C
IT
Y
O F
S T
A U
N T
O N
, V A
S0.0.1
630874
MARCH 1, 2024
COLD FORMED STEEL FRAMING
FIBER REINFORCING
FLOWABLE FILL
STEEL JOISTS
CONCRETE
ACI 318 LAP LENGTHS
AB ANCHOR BOLT
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL, ARCHITECT
AVG AVERAGE
BLDG BUILDING
BM BEAM
BMC BUILDING MOUNTED CANOPIES
BOT BOTTOM
BRG BEARING
BTWN BETWEEN
CANT CANTILEVER
CFSF COLD FORMED STEEL FRAMING
CIP CAST IN PLACE
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CTR CENTER
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DWG DRAWING
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELECT ELECTRICAL
ELEV ELEVATOR
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EW EACH WAY
EX EXISTING
EXP EXPANSION
EXT EXTERIOR
FB FIXED BASE
FD FLOOR DRAIN
FDN FOUNDATION
FF FINISHED FLOOR
FIN FINISHED
FLR FLOOR
FOB FACE OF BRICK
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FRMG FRAMING
FRT FIRE RETARDANT TREATED
FT FOOT
FTG FOOTING
GA GAGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
GRD GRADE
HD HEADED
HK HOOK
HORIZ HORIZONTAL
HS HIGH STRENGTH
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
ID INSIDE DIAMETER
IN INCH
INFO INFORMATION
INT INTERIOR
JBE JOIST BEARING ELEVATION
JS JOIST SUBSTITUTE
JST JOIST
JT JOINT
K KIP
LBS POUNDS
LF LINEAR FEET (FOOT)
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
M METER(S)
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MBMA METAL BUILDING MANUFACTURER'S
ASSOC
MBS METAL BULIDNG SYSTEM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MM MILLIMETER(S)
NOM NOMINAL
NS NON SHRINK
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR
INSTALLED
OPNG OPENING
OPP OPPOSITE
PAF POWDER-ACTUATED FASTENERS
PC CONC PRECAST CONCRETE
PFBC PRE-FABRICATED BUILDING COLUMN
PLF POUNDS PER LINEAR FOOT
POLY POLYETHYLENE
PPT PRESSURE PRESERVATIVE TREATED
PSF POUNDS PER SQUARE FOOT
PTFE POLYTETRAFLUOROETHYLENE
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCING, REINFORCED
REQ'D REQUIRED
SIM SIMILAR
SL SLOPE
SOG SLAB ON GRADE
SPA SPACES
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRY(RICAL)
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TF TRANSFER FORCE
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TOSL TOP OF SLAB
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VB VAPOR BARRIER
VERT VERTICAL
VR VAPOR RETARDER
WP WORK POINT
WWF WELDED WIRE FABRIC
POST INSTALLED ANCHORS & DOWELS
COMPOSITE BEAMS
REVISIONS
DATE DESCRIPTION
/8
A
4 6
B
C
D D
F F
G G
13 20
H
3 8 18
J
9 17
K K
144' - 8"
5.0
S3.1.1
S3.1.1
H S
S 7x
7x 1/
B
P -A
5 7 10 16 19 22 25 27
W 8x31BP-A
W 8x31BP-A
W 8x31BP-A
W 8x31BP-A , P-1
W 8x31BP-A
W 8x31BP-B
W 8x31BP-B
W 8x31BP-B
W 8x31BP-B
W 8x35BP-C
W 8x35BP-B , P-1
W 8x35BP-B , P-1
W 8x35BP-B
W 8x48BP-C
W 8x31BP-B
W 8x31BP-B
W 8x40BP-C
W 8x31BP-A
W 8x35BP-B , P-1
W x3
B P
-B , P
-1
W 8x31BP-B , P-1
W8x31BP-A
W 8x31BP-B
W 8x31BP-A
W 8x31BP-A
W 8x31BP-A
W 8x31BP-B
W 8x31BP-B
W 8x31BP-B
W 8x31BP-A
W 8x31BP-A
W 8x31BP-A
W 8x31BP-A
W 8x31BP-A , P-1
W 8x
BP-A
P-1
W 8x31BP-A
W 8x31BP-A
W 8x31BP-A , P-1
W 8x31BP-B
W8x31BP-A
W 8x31BP-A
W 8x
BP-A
P-1
W8x31
BP-A , P-1
W 8x31BP-A , P-1
W 8x31BP-A , P-1W
8x
BP-A
P-1
W 8x
BP-A
P-1
W 8x
BP-A
P-1
HSS7x7x1/4
BP-A
5.0 6.0
5.0
7.0
6.0
5.0
5.0
5.5
7.0
7.0
8.0 6.06.0
5.5
7.0
7.0
7.0
5.0
W F
.5
5.5
9.5
10.5
9.5 7.5
8.08.5
5.0
9.5 9.0
7.5
9.0
6.0 6.0 7.0
7.0 6.5
6.0
5.0
6.0
-4' - 0"
SHADED AREA DEFINES
EXTENTS OF 6" SLAB
WF2.5
6.0
WF3.0
W 8x31BP-A
W 8x31BP-A
SUMP PIT REFER
TO DWG S3.0.3
SUMP PIT REFER
TO DWG S3.0.3
-4' - 0"
-4' - 0"
SUMP PIT REFER
TO DWG S3.0.3
S3.1.1
#5@16
EACH FACE
#5@16
#5@16
#5@16
#5@16 #5@16 #5@8
#5@8
#5@8
#5@8
#5@8
#5@8
#5@8
AT EXTERIOR
STAIR & ELEV WALL
S3.1.1
S3.1.1
/1
8' - 8" 7' - 2"
20' - 9 7/8"
/8
/4
8' - 8 3/8" 1' - 6 5/8"
/1
/8
7' - 4 1/8" 5' - 7"
WF3.5
WF3.5
#6@8
W F
.0
W F
.0
WF3.0
W F
.0
WF4.0
WF3.5
#5@48
EACH 8" CMU WALL
#5@48
EACH 8" CMU WALL
EACH FACE
SWF3.0
W F
.0
#6@8 #6@8
5.0
WF3.0
#5@16
#5@16 WF4.0
#6@8
6 5/16"
EACH FACE
WF3.5
/8
/4
/8
/8
/8
14' - 4"
4' - 11"
10' - 5"
1' - 11"
13' - 0" 3' - 4"
1' - 1"
3' - 10"
6' - 3" 15' - 4"
2' - 1"
3' - 10"
1' - 1" 2' - 11"
5' - 5" 9' - 11" 5' - 1" 10' - 3" 15' - 0" 5"
35' - 4" 22' - 10 1/2"
5 1/2"4"
7' - 4"
20' - 10 3/16" 10' - 8 13/16" 22' - 1 5/8" 5' - 4 3/8" 16' - 5 13/16" 3' - 4" 17' - 3 3/4" 8' - 6 7/16" 25' - 3" 11' - 4"
WF4.0
7"
AT EACH W8x31 COL ON THIS GRIDLINE REINF WALL FOOTING WITH (4) #5 x 3'-0"
@ 12" OC EACH WAY BOTTOM
SWF3.0
WF3.0
SWF3.0
SWF3.0
S W
F .0
#5@16
#5@16
SWF3.0
/8
/8
#5@24
1' - 8"
J.9
/8
14' - 2"
WF3.5
S3.1.1
1' - 8"
2' - 0"
2' - 0"
S3.1.1
S3.1.1
S3.1.1
S3.1.1
S3.1.1
/8
SWF3.0
-3' - 4"
-2' - 0"
-4' - 0"
-4' - 0"
1' - 3" 34' - 2"
1' - 3"
WF4.0
W F
.0
#6@8
#6@8
W F
.5
#6@8
7"7
/2
-2' - 0"
-4' - 0"
-2' - 8"
-2' - 0"
-2' - 0"
-2' - 8"
-4' - 0"
-5' - 4" -3' - 4"
-3' - 4"
-4' - 8"
-3' - 4"
-2' - 8"
-2' - 0"
-2' - 0"
-2' - 0"
-4' - 0"
-2' - 0"
-2' - 0"
-2' - 0"
-3' - 4"
-4' - 8"
-2' - 8"
-4' - 0"
S3.1.1
EA FACE
/8
#5@16
1' - 7" 1' - 7"
8" CMU
SHEAR WALL
12" CMU
SHEAR WALL
8" CMU SHEAR
WALL ABOVE
8" CMU
SHEAR WALL
8" CMU
SHEAR WALL
8" CMU
SHEAR WALL
8" CMU
SHEAR WALL
8" CMU
SHEAR WALL
SHADED AREA
DEFINES EXTENTS
OF 6" SLAB
SHADED AREA DEFINES
EXTENTS OF 6" SLAB
REINF W/2 LAYERS OF
6x6-W2.9xW2.9 WWF
6.0
-3' - 4" -4' - 0"
-4' - 8"
-4' - 0"
-3' - 4"
-2' - 8"
-3' - 4"
-4' - 8"
-2' - 0"
/4
8" CMU
2'-0" +/-
6.0
6.0
6.0
1' - 8"
#5@12 EW T&B REINF. COORDINATE
POST LOCATIONS & QUANTITY W/
GATE POST MFR.
(+1'-6")
RAMP
1" SLAB RECESS AT
BASE OF RAMP,
REFER TO 2/A6.1.5
(+1'-0")
(+0'-0")
REINF RAMP SLAB W/2
LAYERS OF WWF,
LOCATED 1" FROM TOP
& BOTTOM OF RAMP
7.0
-2' - 0"
RAMP
1' - 4
1' - 4
C
AO
M M O N
W
EA
LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL EN
G I
R E E03-01-2024
PAUL J. GAGNON
Lic. No. 029696
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :0
P
M
FOUNDATION PLAN
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
W E
S T
B E
V E
R L
Y S
T R
E E
T C
IT
Y
O F
S T
A U
N T
O N
, V A
S1.1.1
630874
MARCH 1, 2024
FOUNDATION PLAN NOTES:
1. FINISHED FIRST FLOOR ELEVATION = 1553.75' = REFERENCE DATUM EL (+0'-0"). ALL
STRUCTURAL ELEVATIONS INDICATED ARE REFERENCED FROM THIS ELEVATION, UNO.
2. LOWER LEVEL FLOOR CONSTRUCTION SHALL BE 4" NORMAL WEIGHT CONCRETE SLAB ON GRADE REINFORCED WITH 6x6-W2.9xW2.9 WWF (AT 1" FROM TOP OF SLAB) OVER VAPOR BARRIER OVER 6" GRANULAR BASE COURSE, UNO.
FLOOR CONSTRUCTION INDICATED AS 6" SLAB ON GRADE SHALL BE NORMAL WEIGHT CONCRETE REINFORCED WITH 6x6-W2.9xW2.9 WWF (LOCATED AT 2" FROM TOP OF SLAB) OVER VAPOR BARRIER OVER 6" GRANULAR BASE COURSE.
3. REINFORCE EXTERIOR CMU WALLS, STAIR WALLS AND ELEVATOR WALLS WITH #5@24” OC, UNO.
4. BASE COURSE SHALL BE A CLEAN, DENSELY-GRADED "CRUSHER RUN" MATERIAL WITH A BALANCED FINE CONTENT, SUCH AS VDOT 21A OR 21B STONE. THE BASE COURSE SHALL BE COMPACTED AND SHALL BE
FINISHED TO A FLAT, SMOOTH, LOW-FRICTION SURFACE. COMPACTION SHALL BE MONITORED BY THE ON-SITE TESTING AGENCY.
5. TOP OF ALL INTERIOR FOOTINGS SHALL BE (-0'-8"), UNO.
TOP OF ALL EXTERIOR FOOTINGS SHALL BE (-2'-0"), UNO.
6. ALL INTERIOR WALL FOOTINGS SHALL BE WF2.0, UNO.
ALL EXTERIOR WALL FOOTINGS SHALL BE WF2.5, UNO.
7. COORDINATE FOOTING STEPS WITH ALL UNDERSLAB UTILITIES.
REFER TO FOUNDATION NOTE #4 ON DRAWING S0.0.1.
8. REFER TO DRAWING S0.0.1 FOR GENERAL NOTES, PLAN LEGEND, AND STRUCTURAL ABBREVIATIONS.
9. REFER TO DRAWINGS S3.0.1 AND S3.0.2 FOR TYPICAL FOUNDATION DETAILS AND SCHEDULES.
10. AT OPENINGS IN SITE WALLS, PROVIDE LINTEL L1 AND L FOR BRICK SHELF PER NOTE #2 IN LINTEL SCHEDULE.
11. IF STEEL SUPPORT IS REQUIRED BY THE STAIR MANUFACTURER, POST SHALL BE HSS4x4x1/4 WITH FOOTING AS INDICATED
PER THE THICKENED SLAB DETAILS ON DRAWING S3.0.2.
12. WALLS INDICATED AS ARE SHEAR WALLS. SHEAR WALLS SHALL BE GROUTED SOLID (UNO) WITH CONTROL JOINTS AS INDICATED AND NO CLOSER THAN 30'-0" OC. NO REINFORCING IN THESE WALLS IS ALLOWED TO BE CUT. LOCATE ALL PIPING AND CONDUIT OUTSIDE OF REINFORCED CELLS. TWO VERTICAL REINFORCING BARS, SPACED 8" APART, SHALL BE LOCATED AT EACH END OF THE SHEAR WALL. ALL VERTICAL REINFORCEMENT IS FULL WALL HEIGHT, UNO. BELOW GRADE SHEAR WALL PENETRATIONS SHALL BE LOCATED IN THE MIDDLE THIRD OF THE SHEAR WALL LENGTH.
1/8" = 1'-0"
FOUNDATION PLAN
1/8" = 1'-0"
FOUNDATION PLAN - DUMPSTER ENCLOSURE
FOUNDATION PLAN NOTES - DUMPSTER ENCLOSURE:
1. REINFORCE 8" CMU WALLS WITH #5@8" OC.
2. PROVIDE WF4.0 WALL FOOTING.
3. PROVIDE BP-A AT GATE POSTS W/ (4) 5/8" DIAMETER x 8" SCREW ANCHORS.
A A
4 6
B B
C C
D D
F F
G G
13 20
H H
3 8 18
J J
9 17
K K
W24x55 W21x44 (+14' - 11") W18x35 W21x44
W x5
W x1
W x3
W16x26W16x26W16x26
W x4
W x1
W x2
W30x90
W30x90
W21x44
W24x55
W24x55
W21x44 W16x36 [NC]
W x1
W21x44W16x36 W24x55
W24x55
W x5
W x2
W24x62 W21x44
W x2
W x2
W x1
W21x44 W x1
W x1
W x1
W x1
W x2
W x2
W x3
W x3
W x3
W21x44
W x1
W x2
W x2
W x2
W x2
W x2
W x1
W x1
W x1
W x1
W x1
W x2
W x2
W x2
W x2
W x2
W24x55
W x2
W x2
W x3
W21x44
W x2
W x2
W x2
W x2
W x2
W x2
W x4
W x2
W x2
W x2
W x4
N C
W x2
W x2
W x4
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x2
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W10x12
W21x44
W x1
W x2
W x2
W x2
W x1
W14x22
W x2
W x2
W x2
W x2
S4.1.1
S4.1.1
S4.1.1
W14x22
W x3
W x3
W x3
W x3
W21x44
W18x35 [NC] W18x35 W16x26 W16x26 W24x55
W14x22
W x2
W x4
W x3
W x3
W x2
N C
W18x35 W18x35
W x1
5 7 10 16 19 22 25 27
S4.1.1
W16x26
5"
W10x12
W x3
W x1
W x1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
S4.1.1
24K10
24K10
24K10
24K10
24K10
24K10
24K10
24K10
24K10
24K10
24K10
24K10
24K10
/8
4' - 7"
HSS6x5x1/4 W/
W x2
W x2
CONNECT SLAB TO CMU WITH
L4x4x1/4 AND WITH 5/8” DIA
ADHESIVE ANCHORS AT 8” OC,
GROUT CMU SOLID AT ANCHORS.
HSS7x5x1/4 BELOW
5"
(1
E Q
S P
A C
E S
STAIR 2STAIR 1
STAIR 3
STAIR 4
W10x12
W x1
5"
5"
W x1
ALL CANOPY MEMBERS ARE
HSS 8x3x1/4 UNO AND AT
ELEVATION (+9' - 5 1/8") UNO
10' - 0"
/8
W x1
W10x12
W x3
/1 " 12
S4.1.1
S4.1.1
CONNECT HSS4x4 TO EACH HSS7x7 COLUMN
G.9
J.9
W x2
W x2
W x2
W18x35
W8x24 W8x24 W8x24
W x1
W x3
L2
L
L
L
L
L
L
L
L1
L1
L
L
L
L1
L1L1L1
L 1L
L1L1L1
L2
L
L1 L2 L2
L2
L
W x2
8" CMU SHEAR WALL BELOW & ABOVE SLAB
L1
W x1
W x1
EQ EQ
EQ EQ
JB
E
JB
E
ALL CANOPY MEMBERS ARE
HSS 8x3x1/4 UNO AND AT
ELEVATION (+9' - 5 1/8") UNO
6' - 1 7/8" 6' - 11 13/16"
/2 k k k k
50k 50k
3" JOIST BEARING
SEATS AT EACH END
5"
L2
W10x12
BP3
12 - #5 x 12'-0" AT 12"OC AT
MID-DEPTH OF 5" SLAB
S4.1.1
S4.1.1
5"
S4.1.1 w/ 2ND L1 AT LOUVER
L1
L
5"
PROVIDE CONT L5x5x5/16
AT SIDES OF ALL FLOOR
OPENNINGS. WELD L5x5
TO BEAM FLANGE
SIM
SIM
SIM
PROVIDE 5/10" BENT PL W/
DBA ALONG THIS
OPENING (SIM TO 6/S4.1.1)
L1, TYPICAL AT 5
LOCATIONS
ALONG THIS WALL C
AO
M M O N
W
EA
LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL EN
G I
R E E03-01-2024
PAUL J. GAGNON
Lic. No. 029696
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :0
P
M
SECOND FLOOR
FRAMING PLAN
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
W E
S T
B E
V E
R L
Y S
T R
E E
T C
IT
Y
O F
S T
A U
N T
O N
, V A
S2.1.1
630874
MARCH 1, 2024
FLOOR FRAMING PLAN NOTES:
1. TOP OF SECOND FLOOR SLAB (+15'-4") RELATIVE TO FINISHED FIRST FLOOR.
2. TOP OF STEEL BEAMS SHALL BE (-0'-5") RELATIVE TO FINISHED SECOND FLOOR, UNO.
3. TOP OF STEEL BEAMS INDICATED THUS (+X'-X") ON PLAN SHALL BE REFERENCED
FROM FINISHED FIRST FLOOR ELEVATION.
4. FLOOR CONSTRUCTION SHALL BE 3" NORMAL WEIGHT CONCRETE SLAB ON 2" COMPOSITE
FLOOR DECK TYPE 2 (5'' TOTAL SLAB THICKNESS). REINFORCE SLAB WITH
6x6-W2.9xW2.9 WWF AT MID-DEPTH. REFER TO DRAWING S4.0.1 FOR STEEL DECK SCHEDULE.
5. PLACE CONCRETE MONOLITHICALLY ON STEEL FLOOR DECK. CONSTRUCTION JOINTS MAY BE PERMITTED
ONLY AFTER APPROVAL OF THE ARCHITECT / STRUCTURAL ENGINEER.
6. CONCRETE THICKNESS INDICATED ON FLOOR DECK SHALL BE OF A UNIFORM THICKNESS.
7. ALL FLOOR BEAMS SHALL RECEIVE 3/4" DIAMETER x 4" LONG HEADED SHEAR STUDS AT 12" OC, UNO.
ALL BEAMS NOTED [NC] SHALL BE NON-COMPOSITE (SHEAR STUDS NOT REQUIRED).
AT ALL FLOOR BEAMS AT OR LIGHTER THAN A W14x22, DESIGN END OF BEAM CONNECTION FOR A 20K REACTION, UNO.
AT ALL W16 FLOOR BEAMS, DESIGN END OF BEAM CONNECTIONS FOR A 30K REACTION, UNO.
AT ALL W18 FLOOR BEAMS, DESIGN END OF BEAM CONNECTIONS FOR A 40K REACTION, UNO.
AT ALL W21 FLOOR BEAMS, DESIGN END OF BEAM CONNECTIONS FOR A 50K REACTION, UNO.
AT ALL W24 FLOOR BEAMS, DESIGN END OF BEAM CONNECTIONS FOR A 70K REACTION, UNO.
AT ALL W30 FLOOR BEAMS, DESIGN END OF BEAM CONNECTIONS FOR A 70K REACTION, UNO.
8. COMPOSITE BEAMS ARE DESIGNED UNSHORED.
9. ALL BEAMS ARE EQUALLY SPACED BETWEEN COLUMN GRIDLINES, UNO.
10. REFER TO DRAWING S0.0.1 FOR GENERAL NOTES, PLAN LEGEND, AND STRUCTURAL ABBREVIATIONS.
11. REFER TO DRAWINGS S4.0.1 AND S4.0.2 FOR TYPICAL FRAMING DETAILS AND SCHEDULES.
12. COMPOSITE SLABS (3" CONCRETE ON 2" DECK (5" TOTAL)) HAVE BEEN DESIGNED TO ACCOMMODATE A LIFT SIMILAR TO SKYJACK SJIII 3215/19. LIFTS SHALL NOT EXCEED THIS TOTAL WEIGHT, WEIGHT PER SQUARE FOOT OF LIFT FOOTPRINT AREA OR INDIVIDUAL WHEEL LOAD. NO TWO LIFTS SHALL BE WITHIN 20 FEET OF EACH OTHER IN ANY DIRECTION AT ANY TIME. LIFTS SHALL NOT BE LOCATED ADJACENT TO STOCKPILES OF MATERIAL. FLOOR SLABS SHALL HAVE REACHED THEIR 28 DAY DESIGN STRENGTH PRIOR
TO PLACING ANY LIFT ON THE SLAB.
1/8" = 1'-0"
SECOND FLOOR FRAMING PLAN
A
4 6
C
D
G
13 20
H
3 8 18
J
9 17
K
W21x50 (+31' - 2 1/2")
W16x26 (+30' - 5 1/2") W18x40 (+30' - 5 1/2")
K C
S
W x2
J)
W18x35 (+30' - 5 1/2") W16x26 (+30' - 5 1/2") W14x22 (+30' - 5 1/2")
W24x62 (+30' - 5 1/2")
W x4
J)
W18x40 (+30' - 5 1/2") W18x40 (+30' - 5 1/2")
W x2
J)
W14x22 (+31' - 0 1/2")W14x22 (+31' - 0 1/2")W14x22 (+31' - 0 1/2")W21x44 (+31' - 0 1/2")W21x55 (+31' - 0 1/2")
W24x55 (+30' - 5 1/2")
K
K
W x3
J)
K C
S
K
K
K
K
K
K
K C
S
K
K C
S
K C
S
W x2
K
K
K
K
W x2
K
W16x31 (+31' - 2 1/2") W18x35 (+31' - 2 1/2")
W27x102 (+31' - 8 1/2")
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
W18x35 (+31' - 8 1/2")
W18x35 (+31' - 2 1/2")
W21x50 (+31' - 8 1/2")
K
K
K
K
K
K
K C
S
K C
S
K C
S
K C
S
K C
S
K
K
K C
S
K
K
K
K
W x2
J)
K C
S
K C
S
K C
S
K C
S
K
K
W x3
K
K
K
K
K
K
K
K
K
K
K
K C
S
K
K
K
K
K
K
K
K C
S
K C
S
K C
S
K C
S 2 W x2
J)
W x1
J)
W x2
J)
K
K
K
K
K
K
K
K
K
K
K
K C
S
K
K
K
K
K
K
K
K
K
K
S4.2.1
S4.2.1
W x1
J)
S4.2.1
K
K
5 7 10 16 19 22 25 27
K
K
K
K
K
W16x31 (+31' - 2 1/2")
W16x31 (+31' - 8 1/2")
W16x26 (+30' - 5 1/2")
W x5
J)
K
S4.2.1
S4.2.1
S4.2.1
S4.2.1
S4.2.1
S4.2.2
W18x35 (+30' - 5 1/2")
S4.2.2
S4.2.2
S4.2.2
S4.2.2
W16x26 (+31' - 0 1/2")
RTU-2
8650 LBS
RTU-1
6457 LBS
K C
S
W x2
J)
S4.2.1
K
K
S4.2.1
S4.2.1
K
K
K
K
W16x26 (+30' - 8")
ROOF HATCH
S4.2.2
S4.2.2
W12x14
W12x14
W x1
J)
" W18x35
/2 " 9
S4.2.2
G.9
J.9
K C
S
K C
S
K C
S
K
CFSF BOX BEAM HEADER
WITH CFSF JAMBS CFSF BOX BEAM HEADER
WITH CFSF JAMBS
L
K
K
K
L
L
L
L
L
L1
L
L1
L
L
L
L
L
L
L
L3
L
L1
L2
NOTE 9
EQ EQ
S4.2.1
SIM
W x2
J)
K
NOTE 12
NOTE 11
NOTE 10
NOTE 12
W x2
J)
NOTE 13
CONT MC6
CONN SRD TO CMU WALL
PER SECTION 7/S4.2.1(SIM)
NOTE 14
EXTEND DOUBLE HSS'S TO GRIDLINE 23
JBE (+30'-4")JBE (+30'-4")
JBE (+30'-4")
JBE (+31'-4")
JBE (+31'-4")
C
AO
M M O N
W
EA
LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL EN
G I
R E E03-01-2024
PAUL J. GAGNON
Lic. No. 029696
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :1
P
M
ROOF FRAMING PLAN
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
W E
S T
B E
V E
R L
Y S
T R
E E
T C
IT
Y
O F
S T
A U
N T
O N
, V A
S2.2.1
630874
MARCH 1, 2024
ROOF FRAMING PLAN NOTES:
1. TOP OF STEEL BEAMS INDICATED THUS (+X'-X") ON PLAN SHALL BE REFERENCED FROM
FINISHED FIRST FLOOR ELEVATION.
2. STEEL ROOF DECK SHALL BE 1 1/2" WIDE RIB ROOF DECK (DECK TYPE 1), UNO. REFER TO STEEL DECK SCHEDULE ON DRAWING S4.0.1 FOR DECK TYPES INDICATED ON PLAN. REFER TO FRAMING
PLAN AND ARCHITECTURAL AND STRUCTURAL SECTIONS FOR EXTENT OF DECK TYPES.
3. ALL BEAMS AND JOISTS ARE EQUALLY SPACED BETWEEN COLUMN GRIDLINES, UNO.
4. REFER TO DRAWING S0.0.1 FOR GENERAL NOTES, PLAN LEGEND, AND STRUCTURAL ABBREVIATIONS.
5. REFER TO DRAWINGS S4.0.1 AND S4.0.2 FOR TYPICAL FRAMING DETAILS AND SCHEDULES.
6. WHERE JOISTS BEAR ON TOP OF COLUMN, PROVIDE 1/2" CAP PLATE. COORDINATE SIZE TO
ALLOW FOR JOIST BOLTS WHERE REQUIRED.
7. ELEVATOR HOIST BEAMS SHALL BE W6x25 (+28'-4") AND BEAR ON CMU ELEVATOR WALLS WITH BP1.
COORDINATE HOIST BEAM LOCATION WITH APPROVED ELEVATOR SHOP DRAWINGS.
8. PROVIDE LINTEL AT L1 STAIR AND ELEVATOR DOOR OPENINGS, UNO.
9. BEAR JOIST ON STIFFENED L5x5x3/8 x 1'-0" SEAT WELDED TO COLUMN WITH 3/16" FILLET
WELD ALL AROUND. COPE BEAM FLANGE IF NEEDED.
1/8" = 1'-0"
ROOF FRAMING PLAN
10. DOUBLE HSS2 1/2x2 1/2x1/4 WITH L4x4x1/4 x 0'-4" SEAT AT EACH END. WELD SEAT TO TOP CHORD OF JOIST AND BEAM FLANGE.
11. CONNECT EACH HSS7x7 COLUMN TO W18 TOP FLANGE WITH DOUBLE L CONNECTION TO ALLOW FOR 1" VERTICAL BEAM DEFLECTION.
12. L4x4x1/4 FOR STEEL ROOF DECK SUPPORT CONN L TO CMU PER 7/S4.2.2.
13. EXTEND MC6 TO CMU AND CONNECT TO CMU WITH L3x3x1/4x1'-4" SEAT AND (2) 5/8" DIAMETER SCREW ANCHORS SPACED 12" APART.
14. WELD MC6 WEB TO COLUMN WEB WITH L4x4x3/8 x 0'-5 1/2".
15. PROVIDE L FRAMING AT ROOF DRAINS. FOR DRAIN LOCATIONS, REFER TO DRAWING A10.1.
H H
3 8 18
J J
9 17
K K
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
H S
S x4 x1
/4
S4.2.1
K
K
K
H S
S x4 x1
/4
5 7 19 22 25 27
K
K
S4.2.1
S4.2.1
S4.2.2
S4.2.1
S4.2.2
S4.2.2
S4.2.2
S4.2.2
H S
S x4 x1
/4
W21x44 (+34' - 6")
W16x26 (+38' - 8")
W18x35 (+34' - 6")W18x35 (+34' - 6")
S4.2.2
H S
S x4 x1
/4
CONT L5x5
HSS12x4x3/8 (+35' - 3")HSS12x4x3/8 (+35' - 3")
S4.2.1
J.9
JBE (+38'-8")
JBE (+38'-8")
SIM
C O
N T
L x5
S4.2.2
W x1
J)
HSS12x4x3/8 (+35' - 3")HSS12x4x3/8 (+35' - 3")HSS12x4x3/8 (+35' - 3") SUPPORT L5x5 WITH L4x4x1/4
POST AND PROVIDE BEARING
CONDITION SIMILAR TO 1/S4.2.2
EXTEND 8" CFSF STUD WALLS
TO UNDERSIDE OF HSS AND
PROVIDE DEFLECTION TRACK
AT COLUMNS ON GRID LINE J,
PROVIDE HSS8x4x1/4 BRACKET
TO SUPPORT STEEL ROOF DECK
W21x44 (+34' - 6")
HSS12x4x3/8 (+35' - 3")HSS12x4x3/8 (+35' - 3") 1' - 4"
4' - 11"
C O
N T
L x5
S4.2.2
S4.2.1
C
AO
M M O N
W
EA
LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL EN
G I
R E E03-01-2024
PAUL J. GAGNON
Lic. No. 029696
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :1
P
M
UPPER ROOF AND
CANOPY FRAMING
PLAN
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
W E
S T
B E
V E
R L
Y S
T R
E E
T C
IT
Y
O F
S T
A U
N T
O N
, V A
S2.2.2
630874
MARCH 1, 2024
1/8" = 1'-0"
UPPER ROOF AND CANOPY FRAMING PLAN
UPPER ROOF FRAMING PLAN NOTES
1. SLOPING CANOPY ROOF PLANE SHALL BE SUPPORTED BY A SYSTEM OF CFSF RAFTERS @ 16” OC AND CFSF VALLEY BEAMS. REFER TO ARCH ROOF
PLAN FOR ROOF SLOPES.
BELOW GRADE PIPING WITH
PIPE SLEEVE SIZED TO ALLOW
1" CLEARANCE ALL AROUND
PIPE. FILL SPACE WITH
COMPRESSIBLE MATERIAL
CONTINUOUS
REINFORCING
CONTINUOUS
REINFORCING
BACKFILL EXCAVATION WITH
FLOWABLE FILL OR CONTROLLED
COMPACTED FILL PRIOR TO
FOOTING PLACEMENT
REFER TO CIVIL OR
PLUMBING DWGS
FOR PIPE INVERTS
PIPE TRENCH BACKFILL AT FOOTINGFOOTING SLEEVE
(PIPE PLACED PRIOR TO FOOTING)
CONTINUOUS
REINFORCING
3" CLR, TYP
C L R
T
Y P
LONGITUDINAL
REINF
TOP OF FTG ELEVATION
INDICATED ON PLAN
FOOTING STEP PLAN AT CORNER PLAN AT INTERSECTION
M
IN
M
IN
1'
0" M
IN
M A
X
1' - 0" MIN
1' - 0" MIN
M A
X
H
(2 x H) MIN
CONSTRUCTION JOINT
WALL FOOTING FORMED KEY JOINTWALL FOOTING
WALL FOOTING
3" CLR
C L R
3" CLR
2' - 0" LAP
C L R
SPLICE TOP BARS SIMILARLY
3' - 0" MIN
M
IN
2' - 0" MIN
UTILITY TRENCH SHALL
NOT CROSS THIS PLANE
ADJACENT FOOTING TRENCH
SHALL NOT CROSS THIS PLANE
BOT OF FTG
EXCAVATION SHORING
OR BRACING MAY BE
REQUIRED. REFER TO
CIVIL DWGS
COLUMN AND FOOTING
STEEL COLUMN
REFER TO FDN PLAN
REFER TO FDN
PLAN FOR TOP
OF FOOTING EL
FIN FLOOR
SEPARATE POUR
PROVIDE MIN 3" COVER
AROUND BASE PLATE
AND ANCHOR BOLTS
REFER TO COLUMN BASE
PLATE SCHEDULE
T H
IC
K
N E
S S
FOR FOOTING SIZE AND REINFORCING
REFER TO SPREAD FOOTING SCHEDULE
3" CLR
C L R
/2
N S
G R
O U
T
LONGITUDINAL
REINF
TRANSVERSE
REINFORCING
REFER TO FDN
PLAN FOR FTG
ELEVATION
MASONRY WALL
UNO
EQ
UNO
EQ
T H
IC
K
N E
S S
C L R
WIDTH
3" CLR
LONGITUDINAL
REINF
TRANSVERSE
REINFORCING
REFER TO FDN
PLAN FOR FTG
ELEVATION
MASONRY WALL
UNO
EQ
UNO
EQ
T H
IC
K
N E
S S
C L R
WIDTH
3" CLR
C L R
WITH TOP & BOT
REINFORCING
WITH BOT REINFORCING
COLUMN, PIER AND FOOTING
STEEL COLUMN
REFER TO FDN PLAN
REFER TO FDN
PLAN FOR TOP
OF FOOTING EL
FIN FLOOR
SEPARATE POUR
PROVIDE MIN 3" COVER
AROUND BASE PLATE
AND ANCHOR BOLTS
REFER TO COLUMN
BASE PLATE SCHEDULE
T H
IC
K
N E
S S
FOR FOOTING SIZE AND REINFORCING
REFER TO SPREAD FOOTING SCHEDULE
3" CLR
C L R
VERT DOWELS
W/ STD HOOK
TIES
A T
I N
T E
R
IO
R C
O L S
U
N O
A
T E
X T
E R
IO
R
C O
L S
U
N O
(8) BARS
1 1/2" CLR
/2
C L R
PIER SCHEDULE
REFER TO CONC
P
IE
R S
C H
E D
U L E
R E
F E
R T
O C
O N
C
/2
N S
G R
O U
T
BASE PLATE,
REFER TO SCHEDULE
ANCHOR RODS,
REFER TO
SCHEDULEE
M B
E D
M E
N T
P R
O
JE
C T
IO
N
A S
R E
Q U
IR
E
D
STANDARD BASE (HSS)
MIN FILLET WELD
SIZE PER AISC
BASE PLATE,
REFER TO SCHEDULE
ANCHOR RODS,
REFER TO SCHEDULE
E M
B E
D M
E N
T P
R O
JE
C
T
IO
N
A S
R E
Q U
IR
E
D
STANDARD BASE (W-SHAPE)
5/16
TYP
W-SHAPE COLUMN,
REFER TO PLAN
C
AO
M M O N
W
EA
LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL EN
G I
R E E03-01-2024
PAUL J. GAGNON
Lic. No. 029696
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
N
O R
F O
L K
S T
R E
E T
R
IC
H
M O
N D
V
A
P H
O N
E
-7
X
-5
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
/2
/2
:3 :1
P
M
TYPICAL FOUNDATION
DETAILS
S T
A U
N T
O N
J
D R
C O
U R
T S
F A
C
IL
IT
Y
W E
S T
B E
V E
R L
Y S
T R
E E
T C
IT
Y
O F
S T
A U
N T
O N
, V A
S3.0.1
630874
MARCH 1, 2024
NO…