Addendum 2 Facility Technical Diagrams.pdf
PDF 3 MB Posted
- Attached to
- Electric Bus Charger Installation
- Solicitation number
- 2025-TOWP-TR-01
- Issued by
- Gilpin County, Colorado
About this file
Addendum 2 is a technical documentation package for the Town of Winter Park Transit Maintenance Facility, specifically related to a Request for Bid (RFB) for the Installation of Battery Electric Bus Charging Infrastructure. The document, dated February 10th, 2025, provides detailed technical diagrams and floor plans for the new transit facility located at 275 GCR 5103 in Fraser, Colorado. The architectural drawings include comprehensive technology systems plans, site layouts, floor plans across multiple sectors, and detailed infrastructure mapping for electrical, telecommunications, and technological systems integration.
The technical diagrams reveal a sophisticated transit maintenance facility designed to support battery electric bus operations, with extensive technology infrastructure including network racks, security camera placements, conduit routing, and specialized electrical systems. The facility appears to include multiple functional zones such as bus parking, dispatch areas, maintenance spaces, and dedicated technology rooms. The technology systems documentation specifies detailed requirements for low-voltage systems, including specific mounting heights, cable management protocols, grounding standards, and infrastructure support specifications. The plans indicate preparation for future expansion and integration of advanced technological systems to support the transit facility's operational needs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum 3 ChargePoint Quote.pdf | ||
| Addendum 4 As-Built Documents .pdf | ||
| Addendum 1 Facility Walkthrough .pdf | ||
| TOWP_Bus_Charger_Install_RFB (002).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOLICITATION
DATE
SUBJECT
Addendum 2
Addendum 2 is the attached technical diagrams for the Town of Winter Park Transit Maintenance Facility.
RFB for the Installation of Battery Electric Bus Charging Infrastructure
February 10th, 2025
Addendum 2 Technical Diagrams of the Town of Winter Park Transit Maintenance Facility
H B H B
H B H B
H B
H B
T
T
T
T
REF.DW
TURNING HOUSE
A-201
A-201
A-201
A-301
_____2
A-301
A-301
_____1
A-301
A -1
A -1
124 6 8
K
R R
L
3 5 7 9 11
N
P P
Q Q
BUS PARKING
J
D D
F F
E E
G G
ELEC
BUS WASH
DETAILING EQUIP
IT/TEL
DISPATCH
RR
CORRIDOR
VEST
DRIVE AISLE
SHW
JC
FP WATER
STORAGE
A-301
A-301
A-301
A-301
A-313
A-313
A-310
A-311
A-311
A-311
6' - 6" 8' - 6 3/8" 45' - 2" 40' - 0" 52' - 0" 12' - 0" 6' - 0" 22' - 8" 49' - 4" 5' - 4" 21' - 8"
A-201
A-201
A-201
H H
A-311
120' - 8" 60' - 0" 76' - 4"
WASH EQUIP &
RECLAIM
BOILER
WATER
TREATMENT/ENTRY
RR
SHW
BREAKRM
29' - 6" 4' - 4" 24' - 4" 4' - 4" 24' - 4" 4' - 4" 29' - 6"
A-310
A-312
RR
A-310
A-312
A-312
A-311 Sim
A-311 Sim
20' - 0" 8' - 8" 20' - 0" 8' - 8" 20' - 0" 8' - 8" 20' - 0" 7' - 4"
31' - 8" 28' - 8" 28' - 8" 31' - 8"
/8
502B502C502D502E
205C205B
203B
202A
202B
502A
203A
202C
205A
305B
307B
307A
304 303
305A
101B
100A
101A5
/8
/4
6" 3' - 4" 24' - 0" 14' - 0" 6' - 0" 14' - 0"
EW3A
EW4A
BELOW
124.00°
.0
EW3B
EW4A
EW3A
BELOW
EW3AEW4A
BELOW
10.04
EW4A
EW3ABELOW
EW3B
F1
4" TYP.
A-502
Sim
5' - 8 3/8"
10.04
T Y
P
TYP.
4"
EW3B
F1
F1
22.123.07
3.08
22.12 2' - 0"
/8
/8
/1 A-102
A-310
A-551
3' - 8" 12' - 10"
145' - 8 3/8" 95' - 4" 21' - 8"
D.5 D.5
19' - 4" 12' - 0" 28' - 8" 49' - 4" 5' - 4" 21' - 8"
269' - 2 3/8"
A-201.1
A-201.1
A-201.1
100B
205D
94 SF
FACILITIES MAINT
T Y
P
2' - 0" 2' - 0"
4" TYP.
2' - 0"
22.07
MAINTENANCE
26.7
T Y
P
EW4B
BELOW
EW4B
BELOW
FUTURE OH DOOR
14' - 0" 6' - 0"
FUTURE OH DOOR
14' - 0" 4' - 0"
FUTURE DOOR
3' - 4"
6' - 0"
FUTURE OH DOOR
16' - 0" 6' - 0"
/8
4.12 5.67
EW4B
PROJ. NO.
DRAWN:
CHECKED:
DATE:
© OZ ARCHITECTURE
SCALE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
APPROVED:
3003 Larimer Street
Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com
REVISIONS:
ARCHITECTURE
120116.00
/5
/2
:4
:5
P M
B
IM
/1
W in te r
P a rk M a in te n a n c e
/1
.0
W in te r P a rk
M a in te n a n c e A
C e n tr a l.
rv t
3/32" = 1'-0"
W
IN
T E
R P
A R
K P
U B
L
IC
T R
A N
S
IT
O P
E R
A T
IO
N
S F
A C
IL
IT
Y
G
C R
F
R A
S E
R
C O
OZ
OZ
6/30/2022
100% CONSTRUCTION
DOCUMENTS
OVERALL FLOOR PLAN
A-101
WINTER PARK PUBLIC
TRANSIT OPERATIONS
FACILITY
OZ
3/32" = 1'-0"
OVERALL FLOOR PLAN
0' 4' 8' 16' 32' TRUE
NORTH
FLOOR PLAN NOTES
1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF 8655.50'.
2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OF CONCRETE/MASONRY,
COLUMN CENTERLINE, OR CENTERLINE OF WINDOW U.N.O.
3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE/MASONRY, OR
COLUMN CENTERLINE U.N.O. DIMENSIONS DESIGNATED AS "CLEAR" OR "HOLD" SHALL
BE MAINTAINED.
4 SEE SHEET G-502 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIES SHEETS,
FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE 23C, U.N.O.
5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O.
6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OF PARTITION
AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINT ASSEMBLIES.
7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE, THE
CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGN U.N.O.
8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDE JAMB
DIMENSION OF 4" FROM DOOR OPENING TO ADJACENT PERPENDICULAR PARTITION.
9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THE FIRE-RATED
ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS IN ACCORDANCE WITH IBC
CHAPTER 7.
10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION.
11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. IN THE ADMIN AREA. ALL SUCH
LINES SHALL BE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSED
CONSTRUCTION.
12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK, MILLWORK AND
OTHER BUILT-IN ITEMS.
13 SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTURE GRAB BARS.
14 SEE SHEET A-600 FOR DOOR SCHEDULE.
FLAGNOTES WITHIN A VIEW CAN BE ASSUMED TO BE TYP. WITHIN THAT VIEW
PROJECT FLAGNOTES
NO. FLAGNOTE
3.07 CONCRETE CURB, RE: STRUCT.
3.08 FORMED CONCRETE COLUMN BASE, RE: STRUCT
4.12 INDEPENDENT COURSING AT FUTURE PHASE OH DOOR OPENINGS
INDICATED BY GREY HATCH
5.67 PROVIDE FILLABLE BOLLARD SLEEVE FOR FUTURE PHASE DOOR OPENING
10.04 6'-0" TALL CONCRETE FILLED BOLLARD W/ PREFABRICATED TOP, PAINTED
YELLOW
22.07 AREA DRAIN, RE: PLUMBING
22.12 TRENCH DRAIN, RE: PLUMBING
26.7 CARD READER
See RFI 037
TECHNOLOGY SYSTEMS LEGEND
NOTE:
ALL SYMBOLS SHOWN ON LEGEND
ARE NOT NECESSARILY USED.
ABBREVIATIONS
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AP ACCESS POINT
AWG AMERICAN WIRE GAUGE
BAS BUILDING AUTOMATION SYSTEM
BFG BELOW FINISH GRADE
BMS BUILDING MANAGEMENT SYSTEM
C CONDUIT
CATV COMMUNITY (CABLE) ANTENNA TELEVISION SYSTEM
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CPU CENTRAL PROCESSING UNIT
(E) EXISTING
EM EMERGENCY
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS
GC GENERAL CONTRACTOR
IAW IN ACCORDANCE WITH
IC INTERMEDIATE CROSS-CONNECT
IDF INTERMEDIATE DISTRIBUTION FRAME
IG ISOLATED GROUND
IR INFRARED
LAN LOCAL AREA NETWORK
MDF MAIN DISTRIBUTION FRAME
(N) NEW
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
PA PUBLIC ADDRESS
TTB TELECOMMUNICATIONS TERMINAL BOARD
TVTB TELEVISION TERMINAL BOARD
UG UNDERGROUND
UNO UNLESS NOTED OTHERWISE
V VOLT
W WATT
WAN WIDE AREA NETWORK
WAP WIRELESS ACCESS POINT
WLAN WIRELESS LOCAL AREA NETWORK
WP WEATHERPROOF
+18" MOUNTING HEIGHT TO CENTERLINE OF DEVICE ABOVE FINISH
FLOOR (VERIFY W/ ARCH ELEVATIONS)
CLG CEILING MOUNTED
MC MAIN CROSS-CONNECT
POE POWER OVER ETHERNET
ILO IN LIEU OF
TYP. TYPICAL
V
SCHEMATIC/FUNCTIONAL
STRUCTURED CABLING CROSS-CONNECT FIELD
SERVICE PROVIDER DEMARCATION POINT
EQUIPMENT (AS INDICATED)
AMPLIFIER
POTENTIAL TRANSFORMER (CONSTANT VOLTAGE AUDIO)
GROUND
COLD WATER GROUND CONNECTION
BUILDING STEEL GROUND CONNECTION
LOUDSPEAKER
VOLUME CONTROL
CONNECTION
CATV SPLITTER
CATV DIRECTIONAL COUPLER
CATV 4-WAY TAP
CATV 8-WAY TAP
VOICE/DATA
COMMUNICATIONS OUTLET
ANALOG OUTLET
COMBO ANALOG/COMMUNICATIONS OUTLET
POWER/TELECOM POLE
MULTI-OUTLET WIREWAY
OUTLET DESIGNATIONS (XX)
NUMBER OF DATA JACKS NUMBER OF VOICE JACKS
NUMBER OF FIBER JACKS
#D/#V/#F
XX
C - MOUNT ABOVE COUNTER W - WALL PHONE PLATE WITH LUGS
E - ELEVATOR EM - EMERGENCY SERVICES
POS - POINT-OF-SALE
WIRELESS LAN (WI-FI) ACCESS POINT OUTLET
WALL FLOOR CEILING
J
ANALOG CLOCK
SPECIAL SYSTEMS
D DIGITAL CLOCKD
CALL IN SWITCH
M INTERCOM - MAIN STATION
INTERCOM - CALL STATION
CHIME
PA/INTERCOM LOUDSPEAKER
MIC TWO-WAY COMM SPEAKERMIC
C
IC
S
IC
C H
S
S
S
DAS ANTENNA - CEILING MOUNTED
WALL CEILING
V INTERCOM - VIDEO DOOR STATION
2-WAY EMERGENCY COMMUNICATION SYSTEM - CALL BOX
2-WAY EMERGENCY COMMUNICATION SYSTEM - MAIN PANELM
IC
E
E
CHIME STROBEC
H
PUSH BUTTON - DOORBELLDB
ELECTRONIC SAFETY & SECURITY (ESS)
CEILING MOUNTED CAMERA
WALL MOUNTED CAMERA
CORNER MOUNTED CAMERA
CARD READER LOCKSET COMBO
RF GATEWAY - WIRELESS
INTRUSION MOTION SENSOR - WALL MOUNT
INTRUSION MOTION SENSOR - CEILING MOUNT
SECURITY KEYPAD
I
I
S K
RF
REX
CR
L
XX
CREDENTIAL READER
B - BIOMETRIC
P - PROXIMITY
W - WIRELESS
TF - TWO-FACTOR
XX
LOCKING DEVICE
M - MAGNETIC LOCK
Q - LATCH RETRACTOR (QEL)
R - ROD RETRACTOR
S - ELECTRIC STRIKE
XX
REQUEST-TO-EXIT DEVICE
C - PANIC BAR
M - MOTION (PIR)
P - PUSH BUTTON
XX
DOOR POSITION SENSOR
G - GARAGE DOOR
LB - LATCHBOLT SWITCH
M - MAGNETIC CONTACT
XX
PUSHBUTTON FUNCTION
DR - DOOR RELEASE
EM - PANIC / DURESS
CR L
LV
K
CONTROL - HANDHELD REMOTE
CONTROL TOUCHSCREEN FLIP TOP TABLE BOX
SWITCH - 120V
SWITCH - 120V KEYED
SWITCH - LOW VOLTAGE
CONTROLS
CONTROL KEYPAD
CONTROL TOUCHSCREEN (WALL MOUNT)
CONTROL TOUCHSCREEN (WIRELESS)
VOLUME CONTROL
OCC SENSOR - CEILING MOUNTED
C K
C T
C T
V
HH
TB
J
J
J
GENERAL
CEILING MOUNTED JUNCTION BOX
WALL MOUNTED JUNCTION BOX
FLOOR MOUNTED JUNCTION BOX
CONDUIT RUN
CONDUIT RUN BELOW GRADE
CONDUIT UP
CONDUIT DOWN
BONDING BUSBAR (PBB/SBB)
CABLETRAY (PREMISES; NUMBER INDICATES WIDTH/DEPTH)
DEMARCATION POINT
WALL-MOUNT CABINET
EQUIPMENT RACK
WALL-MOUNTED EQUIPMENT RACK
CABLE RUNWAY
CT12/4
AUDIOVISUAL (AV)
TELEVISION OUTLET
AUDIOVISUAL OUTLET
LOUDSPEAKER
LOUDSPEAKER OUTLET
MICROPHONE OUTLET
PROJECTION SCREEN, TV, OR OTHER DISPLAY EQPT
VIDEO PROJECTOR
SPEAKER ZONE HOMERUN
SPK
POINT SOURCE LOUDSPEAKER
AVAVA
V
TVTVT
V
S
MMM
S
WALL FLOOR CEILING
FIRE ALARM
FIRE ALARM CONTROL PANEL
REMOTE ANNUNCIATOR PANEL
MONITORED RELAY
POST-INDICATOR VALVE
CARBON MONOXIDE DETECTOR
SMOKE DETECTOR
HEAT DETECTOR
DUCT DETECTOR
COMBO SMOKE/HEAT DETECTORH
SMOKE DETECTOR W/ SOUNDER BASE
SB
CO
SMOKE DETECTOR W/ CARBON MONOXIDE
T BEAM TYPE SMOKE DETECTOR TRANSMITTER
R BEAM TYPE SMOKE DETECTOR RECEIVER
FIRE ALARM PULL STATION
FIRE ALARM HORN
FIRE ALARM STROBE
FIRE ALARM COMBO HORN/STROBE
FIRE ALARM SPEAKER
FIRE ALARM COMBO SPEAKER/STROBE
FIREMAN'S PHONE JACK
SPRINKLER SYSTEM FLOW SWITCH
SPRINKLER SYSTEM TAMPER SWITCH
FIRE/SMOKE DAMPER
MAGNETIC DOOR HOLD
CEILINGWALL
H
SB
CO
FSD
H
H
F
FACP
FATC
MDH
MR
PIV
F
ANN
F
FF
FT
F
FIRE ALARM TERMINAL CABINET
H
H
F
F
CLG
CLG
CLG
CLG
CLG
FSD
C
O CO
B
D BD
B
D BD
T
R
INDIVIDUAL ADDRESSABLE MODULE
REMOTE TESTER SWITCH
IAM
RTS
NOTES:
- LIGHT LINEWEIGHT INDICATES EXISTING
C
- HATCHED AREAS INDICATE DEMOLITION
- 'C' ADJACENT TO A DEVICE INDICATES
MOUNTING ABOVE COUNTERTOPS
S
TYPICAL DEVICE MOUNTING HEIGHTS
NOTES:
1. IF MOUNTING HEIGHT OF
DEVICES INDICATED HERE
IS IN CONFLICT WITH ADA
REQUIREMENTS DUE TO
INSTALLATION DETAIL, ADA
DIMENSIONS SHALL
GOVERN.
2. RE: ARCH INTERIOR
ELEVATIONS, WHICH SHALL
SUPERCEDE LOCATIONS
SHOWN HERE, UNLESS
LOCATIONS SHOWN ON
INTERIOR ELEVATIONS ARE
NOT CODE COMPLIANT.
FINISH FLOOR LOW VOLTAGE DEVICES
FINISH CEILING
TOP OF DEVICE
TOP OF CABINET
8'-0" CEILING
9'-0" CEILING
SCALE: NONE
OF DEVICE
0"
M A
X
CL
OF DEVICECL
OF DEVICECL
WALL-MTD
CABINET
S
AVTV
SK CRC
M
CK CT V
I
I
I
OFFSET COMMUNICATIONS
DEVICES FROM POWER DEVICES
TO EITHER OPPOSITE SIDE OF
STUD BAY, OR ADJACENT STUD
BAY.
TYPICAL DEVICE ALIGNMENT
FINISH FLOOR
FINISH CEILING
SCALE: NONE
ALIGN DEVICES (OUTLETS,
CONTROLS, ETC.) VERTICALLY.
DO NOT VERTICALLY ALIGN
POWER AND COMMUNICATIONS
DEVICES SIMULTANEOUSLY.
NOTES:
1. IF ALIGNMENT OF DEVICES
INDICATED HERE IS IN
CONFLICT WITH ADA
REQUIREMENTS DUE TO
INSTALLATION DETAIL, ADA
DIMENSIONS SHALL GOVERN.
2. REFERENCE ARCHITECTURAL
INTERIOR ELEVATIONS.
LOCATIONS SHOWN ON
INTERIOR ELEVATIONS SHALL
SUPERCEDE LOCATIONS
SHOWN HERE, UNLESS
LOCATIONS SHOWN ON
INTERIOR ELEVATIONS ARE
NOT CODE COMPLIANT.DOOR WINDOW
ACCESS
CONTROL
OUTLET
ABOVE
COUNTER
DEVICE
CL
CL
EQ EQ
CL
6"
BACKSPLASH
COUNTERTOP
CL
6" M
IN
M A
X
TYPICAL DEVICE MOUNTING HEIGHTS
FINISH FLOOR
FINISH CEILING
TOP OF DEVICE
TOP OF CABINET
TOP OF CABINET
MINIMUM, TOP OF DEVICE
BOTTOM OF DEVICE
M A
X , 8
0" M
IN
SCALE: NONE
6" M
IN
NOTES:
1. IF MOUNTING HEIGHT OF
DEVICES INDICATED HERE
IS IN CONFLICT WITH ADA
REQUIREMENTS DUE TO
INSTALLATION DETAIL, ADA
DIMENSIONS SHALL
GOVERN.
2. REFERENCE
ARCHITECTURAL INTERIOR
ELEVATIONS. LOCATIONS
SHOWN ON INTERIOR
ELEVATIONS SHALL
SUPERCEDE LOCATIONS
SHOWN HERE, UNLESS
LOCATIONS SHOWN ON
INTERIOR ELEVATIONS ARE
NOT CODE COMPLIANT.
FIRE ALARM DEVICES
FACP
ANN
H S
H F
F
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www.bgbuildingworks.com Project No. 10295.00 Copyright 2021
PROJ. NO.
DRAWN:
CHECKED:
DATE:
© OZ ARCHITECTURE
SCALE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
APPROVED:
3003 Larimer Street
Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com
ARCHITECTURE
120116
/1
4/
:3 7:
A
M B
IM
W in te r P ar k
M ai nt en an ce
/1
.0
0- M
E P
T -v
.r vt
As indicated
W
IN
T E
R P
A R
K P
U B
L
IC
T R
A N
S
IT
O P
E R
A T
IO
N
S F
A C
IL
IT
Y
G C
R
3, F R
A S
E R
, C O
JEB
ELR
11/09/2022
ADDENDUM #2
TECHNOLOGY
SYSTEMS COVER
SHEET
TS-000
WINTER PARK PUBLIC
TRANSIT OPERATIONS
FACILITY
ELR
TECHNOLOGY SHEET INDEX
# TITLE
ISSUE LOG
0%
D D
.1 6.
D E
S
IG
N D
E V
E
LO
P M
E N
T
.3
0.
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
6.
.2
A D
D E
N D
U M
7.
.2
0%
C D
S
2.
.2
A D
D E
N D
U M
TS-000 TECHNOLOGY SYSTEMS COVER SHEET √ √ √ √ √
TS-001 TECHNOLOGY SYSTEMS SCHEDULES √ √ √
TS-100 TECHNOLOGY SYSTEMS SITE PLAN √ √
TS-101 TECHNOLOGY SYSTEMS LEVEL 1 FLOOR PLAN √ √ √ √ √
TS-102 TECHNOLOGY SYSTEMS LEVEL 1 FLOOR PLAN -
SECTOR A
TS-103 TECHNOLOGY SYSTEMS LEVEL 1 FLOOR PLAN -
SECTOR B
TS-104 TECHNOLOGY SYSTEMS LEVEL 1 FLOOR PLAN -
SECTOR C
TS-106 TECHNOLOGY SYSTEMS ROOF PLAN √
TS-401 TECHNOLOGY SYSTEMS ENLARGED PLANS √ √ √ √
TS-501 TECHNOLOGY SYSTEMS RISER DIAGRAMS AND
FUCNTIONALS
TS-503 ELECTRONIC SECURITY AND FIRE ALARM
FUNCTIONALS
TS-601 COMMUNICATIONS DIAGRAMS √ √ √ √
TS-603 ELECTRONIC SECURITY DIAGRAMS √ √ √ √
GENERAL NOTES:
1. THESE DRAWINGS ACCOMPANY THE PUBLISHED CONSTRUCTION DOCUMENT SPECIFICATION BOOK (PROJECT MANUAL).
2. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF
WORK.
3. WORK ASSOCIATED WITH TECHNOLOGY SYSTEMS REQUIRES CAREFUL, DETAILED COORDINATION, BOTH PREPARTORY AND ON- SITE, BETWEEN THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR, AND THE TECHNOLOGY SYSTEMS CONTRACTOR(S).
LACK OF PLANNING, COORDINATION, OR SKILL ON PART OF ANY PARTY ASSOCIATED WITH THE SCOPE OF WORK INDICATED WILL NOT BE ACCEPTED AS REASON FOR INSTALLATION THAT DOES NOT MEET SPECIFICATIONS OR INDUSTRY STANDARDS.
4. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS
REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS.
5. REVIEW ENTIRE CONTRACT DOCUMENT PACKAGE (INCLUDING ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND OTHER
DRAWINGS AND SPECIFICATIONS) PRIOR TO BID.
6. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER.
7. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL AND STATE ADOPTED CODES AND ORDINANCES. 2014 EDITION OF NFPA 70 – NATIONAL ELECTRICAL CODE SHALL BE MET AT A MINIMUM. APPLICABLE VOLUMES OF NFPA (NFPA 72, NFPA 75, NFPA 76, NFPA 99, NFPA 101, ETC.) SHALL BE ADHERED TO AT A MINIMUM.
8. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST APPLICABLE STANDARDS AND RECOMMENDATIONS AS PUBLISHED BY AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA), ELECTRONIC INDUSTRIES ALLIANCE (EIA), INSULATED CABLE ENGINEERS ASSOCIATION (ICEA), INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE), SECURITY INDUSTRY ASSOCIATION (SIA), BUILDING INDUSTRY CONSULTING SERVICES
INTERNATIONAL (BICSI), AND INFOCOMM INTERNATIONAL.
9. PROVIDE WITH SHOP DRAWING SUBMITTAL, 1/4” SCALE LAYOUT DRAWINGS OF ROOMS WITH COMMUNICATIONS, AUDIOVISUAL, AND SECURITY DISTRIBUTION OR HEAD-END EQUIPMENT. LAYOUTS SHALL SHOW LOCATIONS OF, AND SHALL BE COORDINATED
WITH ELECTRICAL AND MECHANICAL EQUIPMENT. ALL EQUIPMENT SHALL BE DRAWN TO SCALE.
10. CONTRACTOR’S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A
REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.
11. VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING, AND RACEWAY SYSTEMS PRIOR TO TRENCHING. PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, BACKBONES/SERVICE ENTRANCES (CONDUIT AND/OR CABLING), PULLBOXES, HANDHOLES, MANHOLES, PEDESTALS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC.
REQUIRED. BACKFILL TRENCHES TO 90 PERCENT COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT SERVICE PROVIDER DRAWINGS AND REQUIREMENTS. CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE SERVICE PROVIDERS WITHIN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THEIR REVIEW, APPROVAL, CONSTRUCTION SCHEDULING AND INSTALLATION OF THE PEDESTALS OR PROVIDER-OWNED
MANHOLES WITH THE SERVICE PROVIDER. NOTIFY OWNER OF ANY SCHEDULING CONFLICTS.
12. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN.
13. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE
BROUGHT TO THE ARCHITECT/ENGINEER’S ATTENTION PRIOR TO INSTALLATION.
14. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER’S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE
WITH EQUIPMENT ACTUALLY SUPPLIED.
15. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION.
16. ALL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY.
17. SYSTEMS SHALL BE TESTED AND VERIFIED UPON COMPLETION OF INSTALLATION. SYSTEMS THAT DO NOT PASS INDUSTRY
STANDARD TESTS SHALL BE CORRECTED AT NO ADDITIONAL COST TO OWNER.
18. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER’S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE
OWNER.
19. PROVIDE SOLUTION-BASED EXTENDED WARRANTIES FOR STRUCTURED CABLING SYSTEMS. PROVIDE ALL NECESSARY
DOCUMENTATION TO OWNER PRIOR TURNOVER.
20. CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT RECORD DRAWINGS ON-SITE WHICH SHALL BE AVAILABLE FOR REVIEW DURING ENGINEER’S SITE OBSERVATIONS. UPON COMPLETION, PROVIDE OFFICIAL SET OF RECORD DRAWINGS TO ARCHITECT, IN FORMAT AS REQUESTED BY OWNER. DRAWINGS SHALL INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS, FIELD
ALTERATIONS, REROUTINGS, ETC.
21. CONDUITS FOR TECHNOLOGY SYSTEMS LARGER THAN TRADE SIZE 1 (1”) SHALL HAVE LONG-RADIUS SWEEPS AT ALL CHANGES IN
DIRECTION. LONG-RADIUS SWEEPS SHALL BE MINIMUM 12X CONDUIT DIAMETER.
22. OUTLET BOXES SHALL BE MINIMUM 4-11/16”x4-11/16”x2-1/2”, METALLIC OR NONMETALLIC AS PROJECT REQUIREMENTS DICTATE.
23. FLEXIBLE METAL CONDUIT SHALL NOT BE USED AS CABLE PATHWAY. ONLY SMOOTH-WALLED METALLIC CONDUIT OR TUBING MAY
BE USED. ALTERNATELY, PLASTIC-TYPE (ENT AND/OR PVC) TUBING MAY BE USED.
24. ALL METALLIC SUPPORT COMPONENTS (CONDUITS, SLEEVES, PATHWAYS, CABLETRAY, J-HOOKS OR OTHER SUPPORT, RACKS, CABINETS, ETC.) SHALL BE BONDED WITH NO SMALLER THAN #6AWG INSULATED (GREEN) COPPER BONDING CONDUCTORS. ALL COMPONENTS SHALL BE BONDED TO TELECOMMUNICATIONS GROUNDING BUS. REFERENCE DRAWINGS AND ANSI J-STD-607-A
STANDARD.
25. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A NYLON PULLTAPE INSTALLED. PULLTAPE SHALL HAVE PHYSICAL LENGTH MARKINGS AND BE RATED FOR 200-LB STRENGTH. EMPTY PATHWAYS SHALL BE IDENTIFIED AS SUCH AT ALL JUNCTION BOXES, PULLBOXES, AND OUTLET/DEVICE BOXES, USING PERMANENT LABELING. LABELING TAG SHALL INDICATE INTENDED USE OF CONDUIT, LOCATION OF PATHWAY ORIGINATION, AND LOCATION OF TERMINATION OF EACH INDIVIDUAL CONDUIT.
26. ALL CABLING SHALL BE INDEPENDENTLY SUPPORTED FROM STRUCTURAL ELEMENTS. CABLING IS NOT ALLOWED TO COME IN CONTACT WITH PIPING, ELECTRICAL CIRCUITS/CONDUITS, LIGHTING FIXTURES, DUCTWORK, OR ANY OTHER INSTALLED SYSTEM.
CABLING SHALL NOT USE STRUCTURAL MEMBERS ALONE AS SUPPORT; APPROPRIATE J-HOOKS, BRIDLE RINGS, OR SIMILAR SHALL
BE USED. CABLING SHALL BE INSTALLED WITH SUPPORTS NO GREATER THAN 5’-0” SPACING.
27. ALL EQUIPMENT SHALL BE INDEPENDENTLY SUPPORTED FROM STRUCTURAL ELEMENTS.
28. PROVIDE PULLBOXES ALONG CONDUIT RUNS AT 100 FEET INTERVALS OR EVERY 180-DEGREES OF BENDS, OR BOTH.
29. CONDUITS MAY NOT CHANGE DIRECTION MORE THAN 90 DEGREES AT ANY SINGLE BEND.
30. CONDULETTE FITTINGS MAY NOT BE USED TO CHANGE PATHWAY DIRECTION AT ANY TIME.
31. FIRE ALARM SYSTEM IS A DESIGN/BUILD SYSTEM THAT SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION (AHJ). INFORMATION CONTAINED HEREIN IS PROVIDED TO INDICATE A SYSTEM INTENT AND GENERAL PERFORMANCE REQUIREMENTS. DEVICE LOCATONS SHOWN ARE FOR BASIC QUANTITY COORDINATION FOR BIDDING PURPOSES AND GENERAL INTER-TRADE COORDINATION. FINAL SYSTEM SHOP DRAWINGS (SUBMITTED TO THE AHJ FOR APPROVAL) SHALL BE PREPARED AND STAMPED BY EITHER A LICENSED FIRE PROTECTION PROFESSIONAL ENGINEER (PE) IN THE STATE OF JURISDICTION, OR FIRE ALARM SYSTEM DESIGNER/CONTRACTOR WITH NICET LEVEL III (OR ABOVE) CERTIFICATION. DESIGN/BUILD CONTRACTOR SHALL, UPON REVIEW OF THE DOCUMENTS, PROVIDE ALLOWANCE FOR ADDITIONAL COMPONENTS (DEVICES, CABLING, ETC.) REQUIRED BEYOND INDICATED SCOPE IN THESE DRAWINGS TO PROVIDE A COMPLETE AND OPERABLE SYSTEM.
ISSUE LOG KEY:
ISSUED AS PART OF SET
NOT PART OF SET
ISSUED FOR INFORMATION ONLY
FIRE ALARM IS SHOWN AS THE BASIS-OF-DESIGN FOR BIDDING PURPOSES BY
DESIGN-BUILD CONTRACTOR. ADDITIONAL DEVICES/EQUIPMENT MAY BE
REQUIRED. REQUIREMENTS OR CODE AMENDMENTS BY THE AUTHORITY HAVING
JURISDICTION (AHJ) SHALL SUPERSEDE INFORMATION CONTAINED HEREIN.
FIRE ALARM SHOP DRAWINGS SHALL BE PROVIDED BY THE FIRE ALARM SYSTEM
CONTRACTOR AS A DEFERRED SUBMITTAL PER 2015 IBC 107.3.4.1.
FIRE ALARM NOTE:
LOW VOLTAGE CONTRACTOR TO PROVIDE PRICING ON ALL AUDIOVISUAL AND
CONTROL SYSTEM DEVICES PER THE DESIGN CONTAINED HEREIN. CONTRACTOR
TO COORDINATE INSTALLATION OF LIGHTING AND CLIMATE CONTROL DEVICES
WITH OTHER TRADES. CONTRACTOR TO PROVIDE PRICING OPTION FOR REMOTE
MONITORING SOFTWARE SUITE FROM CONTROL SYSTEM MANUFACTURER.
CONTRACTOR TO COORDINATE SOFTWARE INSTALLATION WITH BUILDING IT
MANAGER.
PRICING NOTE:
THIS PROJECT REQUIRES INSTALLATION OF PATHWAYS MORE STRINGENT THAN
NFPA 70 REQUIREMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
UNDERSTAND AND INSTALL TO ANSI/TIA-569-B PATHWAY STANDARDS.
UNFAMILIARITY WITH THESE SPECIFIED STANDARDS DOES NOT RELIEVE THE
CONTRACTOR FROM THE PROJECT REQUIREMENTS AND SPECIFICATIONS. NON-
COMPLIANT PATHWAYS WILL NOT BE ACCEPTED.
PATHWAY COMPLIANCE NOTE:
CONTRACTOR SHALL NOT SCALE THESE DRAWINGS TO DETERMINE LOCATIONS
OF DEVICES SHOWN. IF EXACT DIMENSIONS ARE NECESSARY TO BE ADHERED
TO, DIMENSIONS ARE INDICATED WITH CONSTRUCTION DOCUMENTS.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO REFER TO THE ARCHITECTURAL
INTERIOR ELEVATIONS, DETAILS AND REFLECTED CEILING PLANS TO DETERMINE
EXACT LOCATIONS OF COMPONENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY
TO REFER TO THE ARCHITECTURAL INTERIOR.
DEVICE COORDINATION NOTE:
(1)
SPECIFIC NOTES:
A.
GENERAL NOTES:
CCTV CAMERA SCHEDULE
MARK MANUF. MODEL
CAMERA SPECIFICATIONS
DESCRIPTION QTYMOUNTING TYPE RESOLUTION
MIN. ILLUM.
(LUX)
HOR
VIEW
ANGLE DIMENSIONS
CAM-1 AVIGILON 3.0C-H4M-D1-IR SURFACE MINIDOME 3 MP 0.02 LUX 100° 2.9" X 2.9" X 2.0" CEILING-MOUNTED MINIDOME CAMERA. 2 CAM-2 AVIGILON 9C-H4A-3MH-270 PENDANT MULTISENSOR 9 MP 0.025 LUX 270° W/ WALL ARM
15.2" X 10.3" X 11.8"
WALL PENDANT MOUNTED THREE-SENSOR
CAMERA WITH 270° HOR. VIEW RANGE.
CAM-3 AVIGILON 9C-H4A-3MH-270 CORNER MULTISENSOR 9 MP 0.025 LUX 270° W/ WALL ARM
15.2" X 10.3" X
11.8"
9MP MULTISENSOR EXTERIOR PENDANT
MOUNT CAMERA. PROVIDE WALL CORNER
MOUNT BRACKET.
SPECIFIC NOTES:
B. COORDINAGE BLOCKING AT MOUNTING LOCATIONS. VERIFY WEIGHTS AND CENTER OF GRAVITY LOCATIONS WITH STRUCTURAL ENGINEER.
A. SAMSUNG, LG, SHARP EQUIVALENT DISPLAY MANUFACTURERS. MODEL NUMBERS SUBJECT TO CHANGE; PROVIDE CURRENT GENERATION MODEL MEETING REQUIEMENTS
SPECIFIED.
GENERAL NOTES: LEGEND:
VIDEO DISPLAY SCHEDULE
MARK MANUFACTURER
MODEL
NUMBER
NOMINAL
SIZE TYPE
RESOLUTIO
N
REFRESH
RATE MOUNT CONTROL
MOUNT
DESCRIPTION
MANUFACTU
RER MODEL
TO SERVICE PROVIDER
PEDESTAL. RE: CIVIL.
(3) 4" C.
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www.bgbuildingworks.com Project No. 10295.00 Copyright 2021
KEY PLAN
A
B
C
PROJ. NO.
DRAWN:
CHECKED:
DATE:
© OZ ARCHITECTURE
SCALE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
APPROVED:
3003 Larimer Street
Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com
ARCHITECTURE
120116
2/
/2
4:
:3
P
M B
IM
W in te r P ar k
M ai nt en an ce
/1
.0
0- M
E P
T -v
.r vt
1" = 50'-0"
W
IN
T E
R P
A R
K P
U B
L
IC
T R
A N
S
IT
O P
E R
A T
IO
N
S F
A C
IL
IT
Y
G C
R
3, F R
A S
E R
, C O
JEB
ELR
02/18/2022
100% CONSTRUCTION
DOCUMENTS
TECHNOLOGY
SYSTEMS SITE PLAN
TS-100
WINTER PARK PUBLIC
TRANSIT OPERATIONS
FACILITY
ELR
SCALE: 1" = 50'-0"
TECHNOLOGY SITE PLAN
# FLAG NOTES:
NOTES:
1. PROVIDE CONDUIT SLEEVES THROUGH WALLS
TO FACILITATE CABLING. PROVIDE
FIRESTOPPING AS REQUIRED.
2. ALL LOW VOLTAGE CONDUIT STUBBED OUT
ABOVE FINISHED CEILINGS SHALL HAVE LONG
RADIUS SWEEPS.
3. CABLE TIES SHALL BE RELEASABLE AND
COMPOSED OF HOOK AND LOOP, RUBBER OR
SOFT POLYMER. ZIP-TIES OR EQUAL SHALL
NOT BE USED.
4. CABLING SHALL BE ROUTED VIA CONDUIT
FROM OUTLET BOX TO ABOVE ACCESSIBLE
CEILING.
5. HOMERUN CABLING TO SERVING
DISTRIBUTION FRAME. USE J-HOOKS FOR
PATHWAYS ABOVE ACCESSIBLE CEILING.
6. CABLING SHALL NOT RUN UNSUPPORTED FOR
LENGTHS GREATER THAN 5'-0". ALL
VOICE/DATA CABLING SHALL BE TERMINATED
ON RACK MOUNTED PATCH PANELS.
7. PROVIDE EXPANSION CAPABILITY IN CONDUIT
CROSSING BUILIDNG EXPANSION JOINTS. RE:
ARCHITECTRUAL DRAWINGS FOR LOCATIONS.
8. ALL INFRASTRUCTURE SUPPORTING
VOICE/DATA STRUCTURED CABLING SYSTEMS
(RACKING, GROUNDING, PATHWAYS, ETC.)
SHALL MEET BICSI STANDARDS.
9. CONTRACTOR TO PROVIDE BLOCKING AT
PROJECTOR AND DISPLAY LOCATIONS TO
SUPPORT 100LBS.
10. LIGHT LINEWEIGHT INDICATES OFCI
EQUIPMENT.
02/18/2022
SEAL
THIS IS IDENTICAL TO THE OFFICIAL
DIGITALLY SEALED DOCUMENTS
PRODUCED ON THIS SAME DATE.
THIS VERSION IS BEING SUBMITTED
AT THE REQUEST OF THE AHJ. THE
OFFICIAL DIGITALLY SEALED VERSION
IS AVAILABLE FROM THE ENGINEER
UPON REQUEST.
02/18/2022
SEAL
THIS IS IDENTICAL TO THE OFFICIAL
DIGITALLY SEALED DOCUMENTS
PRODUCED ON THIS SAME DATE.
THIS VERSION IS BEING SUBMITTED
AT THE REQUEST OF THE AHJ. THE
OFFICIAL DIGITALLY SEALED VERSION
IS AVAILABLE FROM THE ENGINEER
UPON REQUEST.
2 124 6 8 10
16 17
3 5 7 9 11
13 15
1 14
A A
B B
K
R R
L N
P P
Q Q
J
C
C
D
D
F F
E E
G G
H H
TS-401
3" C.
(3) 4" C. UNDER SLAB.
TO SERVICE PROVIDER
PEDESTAL. RE: CIVIL.
CONDUIT MOUNTED TO BOTTOM
OF STRUCTURE.
TURNING HOUSE
BUS PARKING
ELEC
BUS WASH
DETAILING EQUIP
IT/TEL
DISPATCH
RR
CORRIDOR
BREAKRM
VEST
DRIVE AISLE
SHW
JC
FP WATER
STORAGE
WATER
TREATMENT/ENTRY
BOILER
WASH EQUIP &
RECLAIM
VEST
SHW
RR
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www.bgbuildingworks.com Project No. 10295.00 Copyright 2021
KEY PLAN
A
B
C
PROJ. NO.
DRAWN:
CHECKED:
DATE:
© OZ ARCHITECTURE
SCALE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
APPROVED:
3003 Larimer Street
Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com
ARCHITECTURE
120116
2/
/2
4:
:3
P
M B
IM
W in te r P ar k
M ai nt en an ce
/1
.0
0- M
E P
T -v
.r vt
3/32" = 1'-0"
W
IN
T E
R P
A R
K P
U B
L
IC
T R
A N
S
IT
O P
E R
A T
IO
N
S F
A C
IL
IT
Y
G C
R
3, F R
A S
E R
, C O
JEB
ELR
02/18/2022
100% CONSTRUCTION
DOCUMENTS
TECHNOLOGY
SYSTEMS LEVEL 1
FLOOR PLAN
TS-101
WINTER PARK PUBLIC
TRANSIT OPERATIONS
FACILITY
ELR
SCALE: 3/32" = 1'-0"
TECHNOLOGY LEVEL 1 FLOOR PLAN
# FLAG NOTES:
NOTES:
1. PROVIDE CONDUIT SLEEVES THROUGH WALLS
TO FACILITATE CABLING. PROVIDE
FIRESTOPPING AS REQUIRED.
2. ALL LOW VOLTAGE CONDUIT STUBBED OUT
ABOVE FINISHED CEILINGS SHALL HAVE LONG
RADIUS SWEEPS.
3. CABLE TIES SHALL BE RELEASABLE AND
COMPOSED OF HOOK AND LOOP, RUBBER OR
SOFT POLYMER. ZIP-TIES OR EQUAL SHALL
NOT BE USED.
4. CABLING SHALL BE ROUTED VIA CONDUIT
FROM OUTLET BOX TO ABOVE ACCESSIBLE
CEILING.
5. HOMERUN CABLING TO SERVING
DISTRIBUTION FRAME. USE J-HOOKS FOR
PATHWAYS ABOVE ACCESSIBLE CEILING.
6. CABLING SHALL NOT RUN UNSUPPORTED FOR
LENGTHS GREATER THAN 5'-0". ALL
VOICE/DATA CABLING SHALL BE TERMINATED
ON RACK MOUNTED PATCH PANELS.
7. PROVIDE EXPANSION CAPABILITY IN CONDUIT
CROSSING BUILIDNG EXPANSION JOINTS. RE:
ARCHITECTRUAL DRAWINGS FOR LOCATIONS.
8. ALL INFRASTRUCTURE SUPPORTING
VOICE/DATA STRUCTURED CABLING SYSTEMS
(RACKING, GROUNDING, PATHWAYS, ETC.)
SHALL MEET BICSI STANDARDS.
9. CONTRACTOR TO PROVIDE BLOCKING AT
PROJECTOR AND DISPLAY LOCATIONS TO
SUPPORT 100LBS.
10. LIGHT LINEWEIGHT INDICATES OFCI
EQUIPMENT.
1 07.14.21 ADDENDUM 1
02/18/2022
SEAL
THIS IS IDENTICAL TO THE OFFICIAL
DIGITALLY SEALED DOCUMENTS
PRODUCED ON THIS SAME DATE.
THIS VERSION IS BEING SUBMITTED
AT THE REQUEST OF THE AHJ. THE
OFFICIAL DIGITALLY SEALED VERSION
IS AVAILABLE FROM THE ENGINEER
UPON REQUEST.
02/18/2022
SEAL
THIS IS IDENTICAL TO THE OFFICIAL
DIGITALLY SEALED DOCUMENTS
PRODUCED ON THIS SAME DATE.
THIS VERSION IS BEING SUBMITTED
AT THE REQUEST OF THE AHJ. THE
OFFICIAL DIGITALLY SEALED VERSION
IS AVAILABLE FROM THE ENGINEER
Per RFI 167, Door 302 to have power for card reader, power supplied from S2-47.
C R
L
CR
F
H
FH
L
H
H
HH
H
H
FACP
R E
X M
REX
M
H H
H
H
HH
H
H
FF
FT
H
J
J
J
F
CR
L
REX
M
H
H
CR
REX
M
H
16 17
11 13 15
B
K
L N
J
C C
D
D
F F
E E
G G
6D
6D
2D
6D
CAM-2
TS-401
OH
OH
OH
H H
3" C.
CAM-2
CAM-1
+48"+48"
1D1D
2D
CAM-1
WP
WP
1D
1D
1D
1D
RE: 2/TS-503
+10'-0"
RE: 2/TS-503
+14'-0"
+10'-0"
+10'-0"
ELEC
BUS WASH
DETAILING EQUIP
IT/TEL
DISPATCH
RR
CORRIDOR
BREAKRM
VEST
DRIVE AISLE
SHW
JC
FP WATER
STORAGE
WATER
TREATMENT/ENTRY
BOILER
WASH EQUIP &
RECLAIM
CORR
SHW
RR
RR
+48"
1D
W
1D
RE: 2/TS-503
WP
(2) 4" C.
1D 1D
RE: 2/TS-503
6D
6D
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www.bgbuildingworks.com
Project No. 10295.00 Copyright 2021
KEY PLAN
A
B
C
PROJ. NO.
DRAWN:
CHECKED:
DATE:
© OZ ARCHITECTURE
SCALE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
APPROVED:
3003 Larimer Street
Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com
ARCHITECTURE
120116
/1 /2
:0
:1
P M
B
IM
/1
W in te r
P a rk M a in te n a n c e
/1
.0
-M
E P
T -v
.r v t
1/8" = 1'-0"
W
IN
T E
R P
A R
K P
U B
L
IC
T R
A N
S
IT
O P
E R
A T
IO
N
S F
A C
IL
IT
Y
G
C R
F
R A
S E
R
C O
JEB
ELR
11/14/2022
ADDENDUM #2
TECHNOLOGY
SYSTEMS LEVEL 1
FLOOR PLAN - SECTOR
A
TS-102
WINTER PARK PUBLIC
TRANSIT OPERATIONS
FACILITY
ELR
SCALE: 1/8" = 1'-0"
TECHNOLOGY LEVEL 1 FLOOR PLAN - SECTOR A
# FLAG NOTES:
NOTES:
1. PROVIDE CONDUIT SLEEVES THROUGH WALLS
TO FACILITATE CABLING. PROVIDE
FIRESTOPPING AS REQUIRED.
2. ALL LOW VOLTAGE CONDUIT STUBBED OUT
ABOVE FINISHED CEILINGS SHALL HAVE LONG
RADIUS SWEEPS.
3. CABLE TIES SHALL BE RELEASABLE AND
COMPOSED OF HOOK AND LOOP, RUBBER OR
SOFT POLYMER. ZIP-TIES OR EQUAL SHALL
NOT BE USED.
4. CABLING SHALL BE ROUTED VIA CONDUIT
FROM OUTLET BOX TO ABOVE ACCESSIBLE
CEILING.
5. HOMERUN CABLING TO SERVING
DISTRIBUTION FRAME. USE J-HOOKS FOR
PATHWAYS ABOVE ACCESSIBLE CEILING.
6. CABLING SHALL NOT RUN UNSUPPORTED FOR
LENGTHS GREATER THAN 5'-0". ALL
VOICE/DATA CABLING SHALL BE TERMINATED
ON RACK MOUNTED PATCH PANELS.
7. PROVIDE EXPANSION CAPABILITY IN CONDUIT
CROSSING BUILIDNG EXPANSION JOINTS. RE:
ARCHITECTRUAL DRAWINGS FOR LOCATIONS.
8. ALL INFRASTRUCTURE SUPPORTING
VOICE/DATA STRUCTURED CABLING SYSTEMS
(RACKING, GROUNDING, PATHWAYS, ETC.)
SHALL MEET BICSI STANDARDS.
9. CONTRACTOR TO PROVIDE BLOCKING AT
PROJECTOR AND DISPLAY LOCATIONS TO
SUPPORT 100LBS.
10. LIGHT LINEWEIGHT INDICATES OFCI
EQUIPMENT.
1 DATA OUTLET FOR MECHANICAL CONTROLS.
FIELD-COORDINATE EXACT LOCATION WITH
MECHANICAL CONTRACTOR.
2 ADA PUSH BUTTONS TO BE COORDINATED
WITH ACCESS CONTROL SYSTEM.
3 PROVIDE DOOR POSITION SENSOR FOR
OVERHEAD DOOR. CONNECT TO ACCESS
CONTROL SYSTEM FOR MONITORING
PURPOSES. COORDINATE EXACT DETAILS WITH
DOOR VENDOR.
4 PROVIDE J-BOX WITH CONDUIT SLEEVE TO
ABOVE CEILING FOR OVERHEAD DOOR
OPENERS. CONFIRM WITH OVERHEAD DOOR
CONFIGURATION.
5 PROVIDE WEATHERPROOF HORN/STROBE
NOTIFICATION APPLIANCE AT FIRE
DEPARTMENT CONNECTION, IF REQUIRED.
CONFIRM WITH FIRE PROTECTION VENDOR.
4 11.14.2022 ADDENDUM #2
2 124 6 8 10
3 5 7 9 111
A A
B B
C
C
D D
F F
E E
G G
CAM-2
CAM-3
3" C.
OH
+14'-0"
+14'-0"
TURNING HOUSE
ELEC
IT/TEL
DISPATCH
SHW
JC
SHW
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www.bgbuildingworks.com Project No. 10295.00 Copyright 2021
KEY PLAN
A
B
C
PROJ. NO.
DRAWN:
CHECKED:
DATE:
© OZ ARCHITECTURE
SCALE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
APPROVED:
3003 Larimer Street
Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com
ARCHITECTURE
120116
2/
/2
4:
:4
P
M B
IM
W in te r P ar k
M ai nt en an ce
/1
.0
0- M
E P
T -v
.r vt
1/8" = 1'-0"
W
IN
T E
R P
A R
K P
U B
L
IC
T R
A N
S
IT
O P
E R
A T
IO
N
S F
A C
IL
IT
Y
G C
R
3, F R
A S
E R
, C O
JEB
ELR
02/18/2022
100% CONSTRUCTION
DOCUMENTS
TECHNOLOGY
SYSTEMS LEVEL 1
FLOOR PLAN - SECTOR
B
TS-103
WINTER PARK PUBLIC
TRANSIT OPERATIONS
FACILITY
ELR
SCALE: 1/8" = 1'-0"
TECHNOLOGY LEVEL 1 FLOOR PLAN - SECTOR B
# FLAG NOTES:
NOTES:
1. PROVIDE CONDUIT SLEEVES THROUGH WALLS
TO FACILITATE CABLING. PROVIDE
FIRESTOPPING AS REQUIRED.
2. ALL LOW VOLTAGE CONDUIT STUBBED OUT
ABOVE FINISHED CEILINGS SHALL HAVE LONG
RADIUS SWEEPS.
3. CABLE TIES SHALL BE RELEASABLE AND
COMPOSED OF HOOK AND LOOP, RUBBER OR
SOFT POLYMER. ZIP-TIES OR EQUAL SHALL
NOT BE USED.
4. CABLING SHALL BE ROUTED VIA CONDUIT
FROM OUTLET BOX TO ABOVE ACCESSIBLE
CEILING.
5. HOMERUN CABLING TO SERVING
DISTRIBUTION FRAME. USE J-HOOKS FOR
PATHWAYS ABOVE ACCESSIBLE CEILING.
6. CABLING SHALL NOT RUN UNSUPPORTED FOR
LENGTHS GREATER THAN 5'-0". ALL
VOICE/DATA CABLING SHALL BE TERMINATED
ON RACK MOUNTED PATCH PANELS.
7. PROVIDE EXPANSION CAPABILITY IN CONDUIT
CROSSING BUILIDNG EXPANSION JOINTS. RE:
ARCHITECTRUAL DRAWINGS FOR LOCATIONS.
8. ALL INFRASTRUCTURE SUPPORTING
VOICE/DATA STRUCTURED CABLING SYSTEMS
(RACKING, GROUNDING, PATHWAYS, ETC.)
SHALL MEET BICSI STANDARDS.
9. CONTRACTOR TO PROVIDE BLOCKING AT
PROJECTOR AND DISPLAY LOCATIONS TO
SUPPORT 100LBS.
10. LIGHT LINEWEIGHT INDICATES OFCI
EQUIPMENT.
1 PROVIDE DOOR POSITION SENSOR FOR
OVERHEAD DOOR. CONNECT TO ACCESS
CONTROL SYSTEM FOR MONITORING
PURPOSES. COORDINATE EXACT DETAILS WITH
DOOR VENDOR.
02/18/2022
SEAL
THIS IS IDENTICAL TO THE OFFICIAL
DIGITALLY SEALED DOCUMENTS
PRODUCED ON THIS SAME DATE.
THIS VERSION IS BEING SUBMITTED
AT THE REQUEST OF THE AHJ. THE
OFFICIAL DIGITALLY SEALED VERSION
J
J
F
FH
H
H H
H H
H H
H
H H
H H
J
J
K
R R
L N
N
P P
Q Q
J
G G
BUS PARKING
DISPATCH
CAM-3
H H
OH OH OH OH
1D
1D
1D
RE: 3/TS-503
RE: 3/TS-503
+10'-0"
+10'-0"
+10'-0"
1 1 1 1
+14'-0"
TS-401
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www.bgbuildingworks.com Project No. 10295.00 Copyright 2021
KEY PLAN
A
B
C
PROJ. NO.
DRAWN:
CHECKED:
DATE:
© OZ ARCHITECTURE
SCALE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
APPROVED:
3003 Larimer Street
Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com
ARCHITECTURE
120116
2/
/2
4:
:4
P
M B
IM
W in te r P ar k
M ai nt en an ce
/1
.0
0- M
E P
T -v
.r vt
1/8" = 1'-0"
W
IN
T E
R P
A R
K P
U B
L
IC
T R
A N
S
IT
O P
E R
A T
IO
N
S F
A C
IL
IT
Y
G C
R
3, F R
A S
E R
, C O
JEB
ELR
02/18/2022
100% CONSTRUCTION
DOCUMENTS
TECHNOLOGY
SYSTEMS LEVEL 1
FLOOR PLAN - SECTOR
C
TS-104
WINTER PARK PUBLIC
TRANSIT OPERATIONS
FACILITY
ELR
SCALE: 1/8" = 1'-0"
TECHNOLOGY LEVEL 1 FLOOR PLAN - SECTOR C
# FLAG NOTES:
NOTES:
1. PROVIDE CONDUIT SLEEVES THROUGH WALLS
TO FACILITATE CABLING. PROVIDE
FIRESTOPPING AS REQUIRED.
2. ALL LOW VOLTAGE CONDUIT STUBBED OUT
ABOVE FINISHED CEILINGS SHALL HAVE LONG
RADIUS SWEEPS.
3. CABLE TIES SHALL BE RELEASABLE AND
COMPOSED OF HOOK AND LOOP, RUBBER OR
SOFT POLYMER. ZIP-TIES OR EQUAL SHALL
NOT BE USED.
4. CABLING SHALL BE ROUTED VIA CONDUIT
FROM OUTLET BOX TO ABOVE ACCESSIBLE
CEILING.
5. HOMERUN CABLING TO SERVING
DISTRIBUTION FRAME. USE J-HOOKS FOR
PATHWAYS ABOVE ACCESSIBLE CEILING.
6. CABLING SHALL NOT RUN UNSUPPORTED FOR
LENGTHS GREATER THAN 5'-0". ALL
VOICE/DATA CABLING SHALL BE TERMINATED
ON RACK MOUNTED PATCH PANELS.
7. PROVIDE EXPANSION CAPABILITY IN CONDUIT
CROSSING BUILIDNG EXPANSION JOINTS. RE:
ARCHITECTRUAL DRAWINGS FOR LOCATIONS.
8. ALL INFRASTRUCTURE SUPPORTING
VOICE/DATA STRUCTURED CABLING SYSTEMS
(RACKING, GROUNDING, PATHWAYS, ETC.)
SHALL MEET BICSI STANDARDS.
9. CONTRACTOR TO PROVIDE BLOCKING AT
PROJECTOR AND DISPLAY LOCATIONS TO
SUPPORT 100LBS.
10. LIGHT LINEWEIGHT INDICATES OFCI
EQUIPMENT.
1 PROVIDE DOOR POSITION SENSOR FOR
OVERHEAD DOOR. CONNECT TO ACCESS
CONTROL SYSTEM FOR MONITORING
PURPOSES. COORDINATE EXACT DETAILS WITH
DOOR VENDOR.
02/18/2022
SEAL
THIS IS IDENTICAL TO THE OFFICIAL
DIGITALLY SEALED DOCUMENTS
PRODUCED ON THIS SAME DATE.
THIS VERSION IS BEING SUBMITTED
AT THE REQUEST OF THE AHJ. THE
OFFICIAL DIGITALLY SEALED VERSION
E
TS-401
3 4
6 7
LEVEL 1
100' - 0"
UPSUPS
DISTRIBUTION
RACK
SERVER RACK
S P
A C
E R
E S
E R
V E
D
F O
R O
F E
E Q
U
IP
M E
N T
CCTV SWITCH
NVR
TS-4014
LEVEL 1
100' - 0"
11' - 0"
UPS
ALBUQUERQUE | AVON | DENVER | FORT COLLINS
303.278.3820 www.bgbuildingworks.com Project No. 10295.00 Copyright 2021
PROJ. NO.
DRAWN:
CHECKED:
DATE:
© OZ ARCHITECTURE
SCALE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
APPROVED:
3003 Larimer Street
Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com
ARCHITECTURE
120116
2/
/2
4:
:5
P
M B
IM
W in te r P ar k
M ai nt en an ce
/1
.0
0- M
E P
T -v
.r vt
1/2" = 1'-0"
W
IN
T E
R P
A R
K P
U B
L
IC
T R
A N
S
IT
O P
E R
A T
IO
N
S F
A C
IL
IT
Y
G C
R
3, F R
A S
E R
, C O
JEB
ELR
02/18/2022
100% CONSTRUCTION
DOCUMENTS
TECHNOLOGY
SYSTEMS ENLARGED
PLANS
TS-401
WINTER PARK PUBLIC
TRANSIT OPERATIONS
FACILITY
ELR
SCALE: 1/2" = 1'-0"1 ENLARGED TECHNOLOGY PLAN - IT/TEL [117]
SCALE: 1/2" = 1'-0"2 RACK ELEVATION - IT/TEL [117]
# FLAG NOTES:
NOTES:
1. PROVIDE CONDUIT SLEEVES THROUGH WALLS
TO FACILITATE CABLING. PROVIDE
FIRESTOPPING AS REQUIRED.
2. ALL LOW VOLTAGE CONDUIT STUBBED OUT
ABOVE FINISHED CEILINGS SHALL HAVE LONG
RADIUS SWEEPS.
3. CABLE TIES SHALL BE RELEASABLE AND
COMPOSED OF HOOK AND LOOP, RUBBER OR
SOFT POLYMER. ZIP-TIES OR EQUAL SHALL
NOT BE USED.
4. CABLING SHALL BE ROUTED VIA CONDUIT
FROM OUTLET BOX TO ABOVE ACCESSIBLE
CEILING.
5. HOMERUN CABLING TO SERVING
DISTRIBUTION FRAME. USE J-HOOKS FOR
PATHWAYS ABOVE ACCESSIBLE CEILING.
6. CABLING SHALL NOT RUN UNSUPPORTED FOR
LENGTHS GREATER THAN 5'-0". ALL
VOICE/DATA CABLING SHALL BE TERMINATED
ON RACK MOUNTED PATCH PANELS.
7. PROVIDE EXPANSION CAPABILITY IN CONDUIT
CROSSING BUILIDNG EXPANSION JOINTS. RE:
ARCHITECTRUAL DRAWINGS FOR LOCATIONS.
8. ALL INFRASTRUCTURE SUPPORTING
VOICE/DATA STRUCTURED CABLING SYSTEMS
(RACKING, GROUNDING, PATHWAYS, ETC.)
SHALL MEET BICSI STANDARDS.
9. CONTRACTOR TO PROVIDE BLOCKING AT
PROJECTOR AND DISPLAY LOCATIONS TO
SUPPORT 100LBS.
10. LIGHT LINEWEIGHT INDICATES OFCI
EQUIPMENT.
1 4-POST EQUIPMENT RACK FRAME - PROVIDE
CHATSWORTH OR EQUAL.
2 2-POST EQUIPMENT RACK FRAME - 45U.
PROVIDE CHATSWORTH OR EQUAL.
3 PBB - PRIMARY BONDING BUSBAR. PROVIDE
CHATSWORTH, HARGER, OR EQUAL.
4 VERTICAL CABLE MANAGER - 6" W, DOUBLE
SIDED. PROVIDE CHATSWORTH VELOCITY OR
EQUAL.
5 CABLE RUNWAY - 12" W. PROVIDE
CHATSWORTH OR EQUAL.
6 HORIZONTAL / BACKBONE PATHWAYS. REFER
TO FLOOR PLANS FOR ROUTING.
7 3/4" PLYWOOD BACKBOARD - 'AC' GRADE. PAINT
WITH WHITE FIRE RETARDANT PAINT.
8 SPACE RESERVED FOR FUTURE 2-POST
EQUIPMENT RACK FRAME.
9 19U WALL MOUNT EQUIPMETN CABINET.
PROVIDE CHATSWORTH OR EQUAL.
10 48-PORT PATCH PANEL.
11 2U CABLE MANAGER.
12 2U FIBER SHELF.
13 PROVIDE RACK-MOUNTED SBB BUSBAR IN IDF
CABINET.
14 INCOMING SERVICE CONDUIT - (3) 4" C.
15 OFE - RACK MOUNTED UPS.
SCALE: 1/2" = 1'-0"3 ENLARGED TECHNOLOGY PLAN - IDF CABINET
SCALE: 1/2" = 1'-0"4 IDF CABINET ELEVATION
02/18/2022
SEAL
THIS IS IDENTICAL TO THE OFFICIAL
DIGITALLY SEALED DOCUMENTS
PRODUCED ON THIS SAME DATE.
THIS VERSION IS BEING SUBMITTED
AT THE REQUEST OF THE AHJ. THE
OFFICIAL DIGITALLY SEALED VERSION
| Addendum 2- Technical Diagrams.pdf |
| ARCHITECTURAL |
| A-101 - OVERALL FLOOR PLAN |
| TS-000_V5_2023-03-27_04-12-50pm.pdf |
| TELE |
| TS-000 - SYSTEMS COVER SHEET |
| TS-100_V4_2023-03-27_04-14-08pm.pdf |
| TELE |
| TS-100 - SYSTEMS SITE PLAN |
| TS-101_V4_2023-03-27_04-16-07pm.pdf |
| TELE |
| TS-101 - SYSTEMS LEVEL 1 FLOOR PLAN |
| TS-102_V5_2023-03-27_04-17-40pm.pdf |
| TELE |
| TS-102 - SYSTEMS LEVEL 1 FLOOR PLAN -SECTOR |
| TS-103_V4_2023-03-27_04-18-27pm.pdf |
| TELE |
| TS-103 - SYSTEMS LEVEL 1 FLOOR PLAN -SECTOR |
| TS-104_V4_2023-03-27_04-19-26pm.pdf |
| TELE |
| TS-104 - SYSTEMS LEVEL 1 FLOOR PLAN -SECTOR |
| TS-401_V4_2023-03-27_04-15-13pm.pdf |
| TELE |
| TS-401 - SYSTEMS ENLARGED PLANS |
File details come from the government source that posted it. Updated .