About this file

This document is an Addendum to Invitation to Bid No. RFB-91-25 issued by the Commonwealth of Kentucky Department for Facilities and Support Services Division of Engineering and Contract Administration for Campground Renovation Parks - Campgrounds - Multi Park West at My Old Kentucky Home Campground and Taylorsville Lake Campground in Bardstown and Mt. Eden, Kentucky. The addendum changes the official bid opening date to October 18, 2024 at 1:30 PM ET and refers bidders to an additional addendum with further specification and drawing changes. The project involves renovations to the campgrounds and associated facilities, and the contract is expected to be awarded following the bid opening.

The addendum also provides additional details on the required specifications, including the addition of new sections for plastic-laminate-clad architectural cabinets and plastic-laminate-clad countertops. Bidders are required to acknowledge receipt of the addendum on their official bid documents. No other salient pricing, funding, or contracting details are provided in this addendum.

View the file

Other files

File Type Posted
Final_RFB_785_2500000164_2_SO_FORM.PDF PDF
Addendum 1.pdf PDF
Final_RFB_785_2500000164_3_SO_FORM.PDF PDF
Final_RFB_785_2500000164_1_SO_FORM.PDF PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-91-25

FOR: Campground Renovation Parks - Campgrounds - Multi Park West My Old Kentucky Home Campground Taylorsville Lake Campground Bardstown and Mt. Eden, Kentucky

DATE: October 10, 2024

RFB-785-2500000164

ADDENDUM NO. Two (2)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Change Official Bid Opening date to October 18, 2024, at 1:30 PM ET.

Item 2: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.

END OF ADDENDUM

Invitation to Bid No. RFB-91-25 For: Campground Renovation Parks - Campgrounds - Multi Park West My Old Kentucky Home Campground Taylorsville Lake Campground Bardstown and Mt. Eden, Kentucky

Kristi Sharp, Statewide Procurement Manager Division of Engineering and Contract Administration

Campground Renovation Parks – Campgrounds – Multi Park West My Old Kentucky Home Campground Taylorsville Lake Campground Engineering File No. 670-CB58-CO54-06 C/S Project No. 2326F

RFB 91-25

2024.10.08

Addendum No. 02 _ The original specifications and drawings dated RTA 08/21/24 for the above referenced project are amended as noted in this Addendum.

Receipt of this Addendum shall be acknowledged by inserting its number in the space provided on the Official Bid Document for RFB 91-25

GENERAL

1) Sanitary, water and electrical base files will be provided for Taylorsville Lake for bidding purposes.

SPECIFICATIONS

2) Add the following Specification Sections to the Index: “06 41 16 Plastic-Laminate-Clad Architectural Cabinets” and “12 36 23.13 Plastic-Laminate-Clad Countertops.”

3) Section 06 41 16 Plastic-Laminate-Clad Architectural Cabinets: Add the attached section in its entirety.

4) Section 10 14 26 Post and Panel/Pylon Signage: Revise 2.2.A.2.a as follows: Thickness: 0.080 inch.

5) Section 12 36 23.13 Plastic-Laminate-Clad Countertops: Add the attached section in its entirety.

DRAWINGS

6) Sheet A301 – Add the following notes to elevation 21A301: “Plastic laminate countertop, plastic laminate lockable cabinets and plastic laminate shelf.” Shelf is 7’-0 tall and 2’-6” wide.

Countertop and cabinets are 5’-0 wide and 2’-10” tall.

Parks - Campgrounds - Multi Park West Account # 670-CB58-CO54-06 My Old Kentucky Home & Taylorsville Lake Campgrounds CS Project No.: 2326F

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS 06 41 16 - 1

SECTION 06 41 16 - PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Plastic-laminate-clad architectural cabinets.

2. Cabinet hardware and accessories.

3. Miscellaneous materials.

B. Related Requirements:

1. Section 12 36 23.13 "Plastic-Laminate-Clad Countertops."

1.2 COORDINATION

A. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of Work specified in other Sections to support loads imposed by installed and fully loaded cabinets.

1.3 ACTION SUBMITTALS

A. Product Data:

1. Plastic-laminate-clad architectural cabinets.

2. Cabinet hardware and accessories.

3. Miscellaneous materials.

B. Product Data Submittals: For each product.

C. Shop Drawings:

1. Include plans, elevations, sections, and attachment details.

2. Show large-scale details.

3. Show locations and sizes of furring, blocking, and hanging strips, including concealed blocking and reinforcement specified in other Sections.

4. Show locations and sizes of cutouts and holes for items installed in plastic-laminate architectural cabinets.

5. Apply AWI Quality Certification Program label to Shop Drawings.

D. Samples: For each exposed product and for each color and texture specified, in manufacturer's or manufacturer's standard size.

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS 06 41 16 - 2

1.4 INFORMATIONAL SUBMITTALS

A. Qualification Data: For fabricator.

B. Product Certificates: For the following:

1. Composite wood products.

2. Thermally fused laminate panels.

3. High-pressure decorative laminate.

4. Adhesives.

1.5 QUALITY ASSURANCE

A. Fabricator Qualifications: Employs skilled workers who custom fabricate products similar to those required for this Project and whose products have a record of successful in-service performance.

1. Fabricators Certification: Licensed participant in AWI's Quality Certification Program.

B. Installer Qualifications: Fabricator of products or licensed participant in AWI's Quality Certification Program.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Do not deliver cabinets until painting and similar finish operations that might damage architectural cabinets have been completed in installation areas. Store cabinets in installation areas or in areas where environmental conditions comply with requirements specified in "Field Conditions" Article.

1.7 FIELD CONDITIONS

A. Environmental Limitations without Humidity Control: Do not deliver or install cabinets until building is enclosed, wet-work is complete, and HVAC system is operating and maintaining temperature and relative humidity at levels planned for building occupants during the remainder of the construction period.

B. Field Measurements: Where cabinets are indicated to fit to other construction, verify dimensions of other construction by field measurements before fabrication, and indicate measurements on Shop Drawings. Coordinate fabrication schedule with construction progress to avoid delaying the Work.

1. Locate concealed framing, blocking, and reinforcements that support cabinets by field measurements before being enclosed/concealed by construction and indicate measurements on Shop Drawings.

C. Established Dimensions: Where cabinets are indicated to fit to other construction, establish dimensions for areas where cabinets are to fit. Provide allowance for

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS 06 41 16 - 3

trimming at site, and coordinate construction to ensure that actual dimensions correspond to established dimensions.

PART 2 - PRODUCTS

2.1 ARCHITECTURAL CABINET FABRICATORS

A. Fabricators: Subject to compliance with requirements, available fabricators offering products that may be incorporated into the Work include, but are not limited to, the following:

1. Leininger.

2. Louisville Lumber.

3. Lyndon Millwork.

4. Morgan Smith Ind.

5. Smith Laminating.

6. Stevens.

7. TMI.

8. Top Service.

9. Southern Cabinetry.

2.2 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

A. Quality Standard: Unless otherwise indicated, comply with the Architectural Woodwork Standards for grades of cabinets indicated for construction, finishes, installation, and other requirements.

1. Provide labels and certificates from AWI certification program indicating that woodwork complies with requirements of grades specified.

B. Architectural Woodwork Standards Grade: Premium.

C. Type of Construction: Frameless.

D. Door and Drawer-Front Style: Reveal overlay.

1. Reveal Dimension: 1/2 inch.

E. High-Pressure Decorative Laminate: ISO 4586-3, grades as indicated or if not indicated, as required by quality standard.

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. ABET Inc.

b. Formica Corporation.

c. Laminart LLC.

d. Pionite; a Panolam Industries International, Inc. brand.

http://www.specagent.com/Lookup?ulid=5711 http://www.specagent.com/Lookup?uid=123457225924 http://www.specagent.com/Lookup?uid=123457225925 http://www.specagent.com/Lookup?uid=123457225926 http://www.specagent.com/Lookup?uid=123457225927

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS 06 41 16 - 4

e. Wilsonart LLC.

F. Laminate Cladding for Exposed Surfaces:

1. Horizontal Surfaces: HGS.

2. Vertical Surfaces: VGS.

3. Edges: Grade HGS.

4. Pattern Direction: Vertically for drawer fronts, doors, and fixed panels.

G. Semiexposed Surfaces:

1. Surfaces Other Than Drawer Bodies: High-pressure decorative laminate, ISO 4586- 3.

a. Edges of Plastic-Laminate Shelves: PVC edge banding, 3.0 mm thick, matching laminate in color, pattern, and finish.

b. For semiexposed backs of panels with exposed plastic-laminate surfaces, provide surface of high-pressure decorative laminate, ISO 4586-3, grade to match exposed surface.

2. Drawer Sides and Backs: Solid-hardwood lumber or thermally fused laminate panels with PVC or polyester edge banding.

3. Drawer Bottoms: Hardwood plywood or thermally fused laminate panels.

H. Concealed Backs of Panels with Exposed Plastic-Laminate Surfaces: High-pressure decorative laminate, ISO 4583-3, grade to match exposed surface.

I. Drawer Construction: Fabricate with exposed fronts fastened to subfront with mounting screws from interior of body.

1. Join subfronts, backs, and sides with glued rabbeted joints supplemented by mechanical fasteners.

J. Colors, Patterns, and Finishes: Provide materials and products that result in colors and textures of exposed laminate surfaces complying with the following requirements:

1. As selected by Architect from laminate manufacturer's full range in the following categories:

a. Solid colors, matte finish.

b. Patterns, matte finish.

2.3 WOOD MATERIALS

A. Wood Products: Provide materials that comply with requirements of referenced quality standard for each type of architectural cabinet and quality grade specified unless otherwise indicated.

1. Wood Moisture Content: 5 to 10 percent.

http://www.specagent.com/Lookup?uid=123457225928

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS 06 41 16 - 5

B. Composite Wood Products: Provide materials that comply with requirements of referenced quality standard for each type of architectural cabinet and quality grade specified unless otherwise indicated.

1. Medium-Density Fiberboard (MDF): ANSI A208.2, Grade 130.

2. Particleboard (Medium Density): ANSI A208.1, Grade M-2.

3. Softwood Plywood: DOC PS 1, medium-density overlay.

4. Thermally Fused Laminate (TFL) Panels: Particleboard or MDF finished with thermally fused, melamine-impregnated decorative paper and complying with requirements of ISO 4586.

2.4 CABINET HARDWARE AND ACCESSORIES

A. Butt Hinges: 2-3/4-inch, five-knuckle steel hinges made from 0.095-inch-thick metal, and as follows:

1. Semiconcealed Hinges for Overlay Doors: ANSI/BHMA A156.9, B01521.

B. Wire Pulls: Back mounted, solid metal, 4 inches long, 5/16 inch in diameter.

C. Catches: Magnetic catches, ANSI/BHMA A156.9, B03141.

D. Adjustable Shelf Standards and Supports: ANSI/BHMA A156.9, B04071; with shelf rests, B04081.

E. Drawer Slides: ANSI/BHMA A156.9.

1. Heavy-Duty (Grade 1HD-100 and Grade 1HD-200): Side mount.

a. Type: Full extension.

b. Material: Zinc-plated ball bearing slides.

2. General-purpose drawers more than 3 inches high, but not more than 6 inches high and not more than 24 inches wide, provide 75 lb load capacity.

F. Door Locks: ANSI/BHMA A156.11, E07121.

G. Drawer Locks: ANSI/BHMA A156.11, E07041.

H. Door and Drawer Silencers: ANSI/BHMA A156.16, L03011.

I. Exposed Hardware Finishes: For exposed hardware, provide finish that complies with ANSI/BHMA A156.18 for ANSI/BHMA finish number indicated.

1. Satin Chromium Plated: ANSI/BHMA 626 for brass or bronze base; ANSI/BHMA 652 for steel base.

2. Bright Chromium Plated: ANSI/BHMA 625 for brass or bronze base;

ANSI/BHMA 651 for steel base.

3. Satin Stainless Steel: ANSI/BHMA 630.

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS 06 41 16 - 6

J. For concealed hardware, provide manufacturer's standard finish that complies with product class requirements in ANSI/BHMA A156.9.

2.5 MISCELLANEOUS MATERIALS

A. Furring, Blocking, Shims, and Hanging Strips: Softwood or hardwood lumber, kiln-dried to less than 15 percent moisture content.

B. Anchors: Select material, type, size, and finish required for each substrate for secure anchorage. Provide metal expansion sleeves or expansion bolts for post-installed anchors.

Use nonferrous-metal or hot-dip galvanized anchors and inserts at inside face of exterior walls and at floors.

C. Adhesive for Bonding Plastic Laminate: Contact cement.

1. Adhesive for Bonding Edges: Hot-melt adhesive or adhesive specified above for faces.

2.6 FABRICATION

A. Fabricate architectural cabinets to dimensions, profiles, and details indicated.

B. Complete fabrication, including assembly and hardware application, to maximum extent possible before shipment to Project site. Disassemble components only as necessary for shipment and installation. Where necessary for fitting at site, provide ample allowance for scribing, trimming, and fitting.

1. Notify Architect seven days in advance of the dates and times architectural cabinet fabrication will be complete.

2. Trial fit assemblies at manufacturer's shop that cannot be shipped completely assembled. Install dowels, screws, bolted connectors, and other fastening devices that can be removed after trial fitting. Verify that various parts fit as intended and check measurements of assemblies against field measurements before disassembling for shipment.

C. Shop-cut openings to maximum extent possible to receive hardware, appliances, electrical work, and similar items. Locate openings accurately and use templates or roughing-in diagrams to produce accurately sized and shaped openings. Sand edges of cutouts to remove splinters and burrs.

PART 3 - EXECUTION

3.1 PREPARATION

A. Before installation, condition cabinets to humidity conditions in installation areas for not less than 72 hours.

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS 06 41 16 - 7

3.2 INSTALLATION

A. Architectural Woodwork Standards Grade: Install cabinets to comply with quality standard grade of item to be installed.

B. Assemble cabinets and complete fabrication at Project site to extent that it was not completed in the shop.

C. Anchor cabinets to anchors or blocking built in or directly attached to substrates. Secure with wafer-head cabinet installation screws.

D. Install cabinets level, plumb, and true in line to a tolerance of 1/8 inch in 96 inches using concealed shims.

1. Scribe and cut cabinets to fit adjoining work, refinish cut surfaces, and repair damaged finish at cuts.

2. Install cabinets without distortion so doors and drawers fit openings and are accurately aligned. Adjust hardware to center doors and drawers in openings and to provide unencumbered operation. Complete installation of hardware and accessory items as indicated.

3. Fasten wall cabinets through back, near top and bottom, and at ends not more than 16 inches o.c. with anchors or blocking built-in or directly attached to substrates.

3.3 ADJUSTING AND CLEANING

A. Repair damaged and defective cabinets, where possible, to eliminate functional and visual defects. Where not possible to repair, replace architectural cabinets. Adjust joinery for uniform appearance.

B. Clean, lubricate, and adjust hardware.

C. Clean cabinets on exposed and semiexposed surfaces.

END OF SECTION 06 41 16

PLASTIC-LAMINATE-CLAD COUNTERTOPS 12 36 23.13 - 1

SECTION 12 36 23.13 - PLASTIC-LAMINATE-CLAD COUNTERTOPS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Plastic-laminate-clad countertops.

1.2 ACTION SUBMITTALS

A. Product Data:

1. Plastic-laminate-clad countertops.

2. Accessories.

B. Product Data Submittals: For each product.

C. Shop Drawings: For plastic-laminate-clad countertops.

1. Include plans, sections, details, and attachments to other work. Detail fabrication and installation, including field joints.

2. Show locations and sizes of cutouts and holes for items installed in plastic-laminate-clad countertops.

3. Apply AWI Quality Certification Program label to Shop Drawings.

D. Samples: Plastic laminates in each type, color, pattern, and surface finish required in manufacturer's standard size.

1.3 INFORMATIONAL SUBMITTALS

A. Qualification Data: For fabricator.

B. Product Certificates: For the following:

1. Composite wood products.

2. High-pressure decorative laminate.

3. Adhesives.

1.4 QUALITY ASSURANCE

A. Fabricator Qualifications: Shop that employs skilled workers who custom fabricate products similar to those required for this Project and whose products have a record of successful in-service performance.

PLASTIC-LAMINATE-CLAD COUNTERTOPS 12 36 23.13 - 2

1. Shop Certification: AWI's Quality Certification Program accredited participant.

B. Installer Qualifications: Fabricator of products or AWI's Quality Certification Program accredited participant.

1.5 DELIVERY, STORAGE, AND HANDLING

A. Deliver countertops only after casework and supports on which they will be installed have been completed in installation areas.

B. Store countertops in areas where environmental conditions comply with requirements specified in "Field Conditions" Article.

C. Keep surfaces of countertops covered with protective covering during handling and installation.

1.6 FIELD CONDITIONS

A. Environmental Limitations without Humidity Control: Do not deliver or install countertops until building is enclosed, wet-work is complete, and HVAC system is operating and maintaining temperature and relative humidity at levels planned for building occupants during the remainder of the construction period.

B. Field Measurements: Where countertops are indicated to fit to other construction, verify dimensions of other construction by field measurements before fabrication and indicate measurements on Shop Drawings. Coordinate fabrication schedule with construction progress to avoid delaying the Work.

C. Established Dimensions: Where countertops are indicated to fit to other construction, establish dimensions for areas where countertops are to fit. Provide allowance for trimming at site, and coordinate construction to ensure that actual dimensions correspond to established dimensions.

PART 2 - PRODUCTS

2.1 PLASTIC-LAMINATE-CLAD COUNTERTOPS

A. Quality Standard: Unless otherwise indicated, comply with the "Architectural Woodwork Standards" for grades of plastic-laminate-clad countertops indicated for construction, finishes, installation, and other requirements.

B. Grade: Premium.

C. High-Pressure Decorative Laminate: ISO 4586-3, Grade HGS.

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

http://www.specagent.com/Lookup?ulid=5879

PLASTIC-LAMINATE-CLAD COUNTERTOPS 12 36 23.13 - 3

a. ABET Inc.

b. Formica Corporation.

c. Laminart LLC.

d. Nevamar Company, LLC.

e. Pionite; a Panolam Industries International, Inc. brand.

f. Wilsonart LLC.

D. Colors, Patterns, and Finishes: Provide materials and products that result in colors and textures of exposed laminate surfaces complying with the following requirements:

1. As selected by Architect from manufacturer's full range in the following categories:

a. Solid colors, matte finish.

b. Patterns, matte finish.

E. Edge Treatment: 3.0-mm PVC edging.

F. Core Material: Particleboard or MDF.

G. Core Thickness: 3/4 inch.

1. Build up countertop thickness to 1-1/2 inches at front, back, and ends with additional layers of core material laminated to top.

2.2 WOOD MATERIALS

A. Wood Products: Provide materials that comply with requirements of referenced quality standard unless otherwise indicated.

1. Wood Moisture Content: 5 to 10 percent.

B. Composite Wood Products: Provide materials that comply with requirements of referenced quality standard for each type of countertop and quality grade specified unless otherwise indicated.

1. MDF: Medium-density fiberboard, ANSI A208.2, Grade 130.

2. Particleboard: ANSI A208.1, Grade M-2.

3. Softwood Plywood: DOC PS 1.

2.3 MISCELLANEOUS MATERIALS

A. Adhesive for Bonding Plastic Laminate: Contact cement.

1. Adhesive for Bonding Edges: Hot-melt adhesive or adhesive specified above for faces.

http://www.specagent.com/Lookup?uid=123457184410 http://www.specagent.com/Lookup?uid=123457184411 http://www.specagent.com/Lookup?uid=123457184412 http://www.specagent.com/Lookup?uid=123457184413 http://www.specagent.com/Lookup?uid=123457184414 http://www.specagent.com/Lookup?uid=123457184415

PLASTIC-LAMINATE-CLAD COUNTERTOPS 12 36 23.13 - 4

2.4 FABRICATION

A. Fabricate countertops to dimensions, profiles, and details indicated. Provide front and end overhang of 1 inch over base cabinets.

B. Complete fabrication, including assembly, to maximum extent possible before shipment to Project site. Disassemble components only as necessary for shipment and installation. Where necessary for fitting at site, provide ample allowance for scribing, trimming, and fitting.

1. Trial fit assemblies at fabrication shop that cannot be shipped completely assembled.

Install dowels, screws, bolted connectors, and other fastening devices that can be removed after trial fitting. Verify that various parts fit as intended, and check measurements of assemblies against field measurements before disassembling for shipment.

C. Shop cut openings to maximum extent possible to receive appliances, plumbing fixtures, electrical work, and similar items. Locate openings accurately, and use templates or roughing-in diagrams to produce accurately sized and shaped openings. Sand edges of cutouts to remove splinters and burrs.

1. Seal edges of cutouts by saturating with varnish.

PART 3 - EXECUTION

3.1 PREPARATION

A. Before installation, condition countertops to average prevailing humidity conditions in installation areas.

B. Before installing countertops, examine shop-fabricated work for completion and complete work as required, including removal of packing.

3.2 INSTALLATION

A. Grade: Install countertops to comply with same grade as item to be installed.

B. Assemble countertops and complete fabrication at Project site to the extent that it was not completed in the shop.

1. Provide cutouts for appliances, plumbing fixtures, electrical work, and similar items.

Locate openings accurately and use templates or roughing-in diagrams to produce accurately sized and shaped openings. Sand edges of cutouts to remove splinters and burrs.

2. Seal edges of cutouts by saturating with varnish.

C. Field Jointing: Where possible, make in the same manner as shop jointing, using dowels, splines, adhesives, and fasteners recommended by manufacturer. Prepare

PLASTIC-LAMINATE-CLAD COUNTERTOPS 12 36 23.13 - 5

edges to be joined in shop so Project-site processing of top and edge surfaces is not required. Locate field joints where shown on Shop Drawings.

1. Secure field joints in countertops with concealed clamping devices located within 6 inches of front and back edges and at intervals not exceeding 24 inches. Tighten in accordance with manufacturer's written instructions to exert a constant, heavy-clamping pressure at joints.

D. Scribe and cut countertops to fit adjoining work, refinish cut surfaces, and repair damaged finish at cuts.

E. Countertop Installation: Anchor securely by screwing through corner blocks of base cabinets or other supports into underside of countertop.

1. Install countertops level and true in line. Use concealed shims as required to maintain not more than a 1/8-inch-in-96-inches variation from a straight, level plane.

2. Secure backsplashes to walls with adhesive.

3. Seal joints between countertop and backsplash, if any, and joints where countertop and backsplash abut walls with mildew-resistant silicone sealant or another permanently elastic sealing compound recommended by countertop material manufacturer.

3.3 ADJUSTING AND CLEANING

A. Repair damaged and defective countertops, where possible, to eliminate functional and visual defects. Where not possible to repair, replace countertops. Adjust joinery for uniform appearance.

B. Clean countertops on exposed and semiexposed surfaces.

C. Protection: Provide Kraft paper or other suitable covering over countertop surfaces, taped to underside of countertop at a minimum of 48 inches o.c. Remove protection at Substantial Completion.

END OF SECTION 12 36 23.13

Addendum 2