Addendum 2 21029.pdf
PDF 59 KB Posted
- Attached to
- 591/21029. AGY; M-136 Culvert Replacement
- Solicitation number
- RFQ - 171 - 220000000426
- Issued by
- St. Clair County, Michigan
About this file
This document is Addendum No. 2 to the bidding documents for the M-136 Culvert Replacement Project for Tributary to Brandymore Drain, issued by the Michigan Department of Transportation (MDOT). The addendum revises the bid schedule item description for the 60-inch dual-wall polymer-precoated galvanized steel culvert and clarifies several questions regarding subcontractor prequalification, HAZWOPER training requirements, and the need for verification of soil remediation samples. The original bid due date of July 21, 2022, has been revised to July 27, 2022.
The project is funded under MDOT code 1116 and is located in Fort Gratiot, Michigan, within St. Clair County. The contract requires MDOT prequalification for all subcontractors, and HAZWOPER training is only necessary for crews working on contaminated soil removal, dewatering, and bypass pumping. Verification of soil remediation samples is not required, but record drawings documenting the contaminated soil removal limits are needed.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date Issued: Thursday, July 21, 2022
Department/Agency: Michigan Department of Transportation (MDOT)
Professional: Arcadis of Michigan, LLC
Project Name: M-136 Culvert Replacement Project for Tributary to Brandymore Drain
M-136 at Brandymore Drain Site
Fort Gratiot, Michigan
File No.: 591/21029.AGY
Funding Code: 1116
Original Bid Due Date: 2 pm EST, Thursday, July 21, 2022
Revised Bid Due Date: 2 pm EST, Wednesday, July 27, 2022
ADDENDUM NO. 2
TO: Prospective Bidders
SUBJECT: Revision and Clarification of Bidding Documents
INTENT: The following Addendum items form part of the Bidding Documents and revise the original Bidding Documents dated June 27, 2022, as noted below. Receipt of this
Addendum must be acknowledged by the Bidder in the space provided on the Bid
Form. Failure of a Bidder to acknowledge this Addendum may cause the Bidder to be disqualified.
CHANGES TO PROJECT MANUAL
1. Revise the Bid Schedule, Bid Item 18 Description to the following: Culv, Cl A, 60 inch, dual-wall polymer-precoated galvanized steel.
CHANGES TO PRIOR ADDENDA
None.
CHANGES TO DRAWINGS
1. Revise the new culvert description on MDOT Sheets 7 and 8 to: Culv, Cl A, 60 inch, dual-wall polymer-precoated galvanized steel.
ADDENDUM NO. 2
M-136 Culvert Replacement Project for
Tributary to Brandymore Drain
ATTACHMENTS
None.
CLARIFICATIONS
Question 1: What material is required for the Class A culvert?
Answer 1: As requested by MDOT, the culvert shall be dual-wall polymer-precoated galvanized steel.
Question 2: Is MDOT prequalification required for all subcontractors?
Answer 2: In summary yes. The MDOT 2022 Standard Specifications for Construction are included in the Contract by reference, and Section 108.01 requires: “The Contractor must issue only subcontracts to subcontractors that are prequalified by the Department to perform the classification of the proposed work, if applicable.”
Question 3: Is 40-hour HAZWOPER training required for all workers on site?
Answer 3: The 40-hour HAZWOPER training is required only for crews completing the contaminated soil removal (excluding truck drivers), the excavation dewatering, and bypass pumping work. Work crews for the paving, guard rail, pavement markings, etc.
will not have the potential to come into contact with contaminated media, and therefore HAZWOPER training is not required for workers that do not have the potential for exposure to contaminants.
Question 4: Are verification of soil remediation (VSR) samples required for this work?
Answer 4: VSR samples are not required for this work. However, record drawings are required for documenting the contaminated soil removal limits (i.e. average length, average width, and average depth).
REFERENCES
None.
ACKNOWLEDGEMENT
Acknowledge receipt of this Addendum No. 2 in the space provided on the Bid Form. Failure to do so may subject the Bidder to disqualification. Refer to Division 00 for requirements related to properly acknowledging this Addendum on the Bid Form.
Sincerely, Arcadis of Michigan, LLC
Theodore J. Kremer, PE, CCCA Christopher S. Peters, CPM
Principal Engineer Certified Project Manager