Addendum 1 - L3 Sheet.pdf

PDF 4 MB Posted

Attached to
1632 - Baker Family Learning Center Expansion
Solicitation number
ANE223-ANE2C-6498
Issued by
San Bernardino County, California

About this file

Addendum 1 - L-3 Sheet

This is an addendum technical drawing sheet prepared by Alhambra Group Landscape Architects for the Baker Family Learning Center Expansion project in San Bernardino County, California. The sheet provides detailed specifications and construction details for planting and irrigation systems, including tree planting with root barriers, staking requirements, and subsurface drip irrigation installation. The document specifies materials and installation methods for landscape features, including pole pine trees secured with galvanized ties, root control barriers positioned at grade with minimum 8-inch depth below hardscape, and three emitters per tree drip layout. All irrigation piping must be installed prior to plant layouts, with lateral supply lines running parallel to slopes and drip emitter lines running perpendicular as shown in the technical details. The addendum references Rain Bird XF Series subsurface dripline components for both potable and non-potable applications, including specific tie-down stake placement requirements varying by soil type (three feet for sand, four feet for loam, five feet for clay) and air relief valve installation at high points in drip zones.

The technical specifications include detailed pressure and flow requirements for the irrigation system, with maximum lateral lengths provided in a reference table based on inlet pressure (15–50 psi) and emitter spacing (12, 18, or 24 inches). Installation guidance covers subsurface dripline burial depths, emitter box placement, backflow prevention equipment, controller mounting, and sensor installation for ET system compatibility with Hunter controller models. The drawing incorporates landscape hardscape details, including a mow curb with natural gray concrete smooth trowel finish and specifications for planter grade construction. The sheet is dated August 19, 2011, and represents the 3 of 4 sheets for Job No. 11-101, with all designs, arrangements, and intellectual property retained by Alhambra Group Landscape Architects for this project only.

View the file

Other files

File Type Posted
ATT-PFMD-20260930-11.2-Specifications Book--Baker Family Learning Center Expansion.pdf PDF
Addendum 1 - Roofing Warranty.pdf PDF
ATT-PFMD-20260930-11-Soils Report--Baker Family Learning Center Expansion.pdf PDF
Addendum 1 - L2 Sheet.pdf PDF
ATT-PFMD-20260930-04-Contractor Certification-CARB Compliance--Baker Family Learning Center Expansion.pdf PDF
Addendum No. 2 - Baker Family Learning Center Expansion.pdf PDF
ATT-PFMD-20260930-11.1-Structural Calculations-Baker Family Learning Center Expansion.pdf PDF
ATT-PFMD-20260930-12-Plans--Baker Family Learning Center Expansion - E-M-P-FA-T-L drawings for scale only.pdf PDF
ATT-PFMD-20260930-09-General Conditions--Baker Family Learning Center Expansion.pdf PDF
ATT-PFMD-20260930-08-Prevailing Wage--Baker Family Learning Center Expansion.pdf PDF
ATT-PFMD-20260930-02-Non-Collusion Declaration--Baker Family Learning Center Expansion.pdf PDF
Addendum 1 - Utility Plan.pdf PDF
ATT-PFMD-20260930-12-Plans--Baker Family Learning Center Expansion.pdf PDF
ATT-PFMD-20260930-05-Sample Standard Contract--Baker Family Learning Center Expansion.pdf PDF
Addendum 1 - Architect Narrative.pdf PDF
ATT-PFMD-20260930-01-Bid Advertisement-Baker Family Learning Center Expansion.pdf PDF
Addendum No. 3 - LIB Baker Family Learning Center.pdf PDF
ATT-PFMD-20260930-07-Sample Bond Forms--Baker Family Learning Center Expansion.pdf PDF
ATT-PFMD-20260930-10-Special Conditions-Baker Family Learning Center Expansion.pdf PDF
Addendum 1 Narrative.pdf PDF
ATT-PFMD-20260930-03-Non-Collusion Declaration Subcontractor--Baker Family Learning Center Expansion.pdf PDF
ATT-PFMD-20260930-06-Contractors Affidavit and Final Release--Baker Family Learning Center Expansion.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TREE PLANTING

L - 3 AND STAKING

EPOLE PINE

OCATE OUTSIDE

BALL TYP.

E, SECURED

W / GALV.

TIES MIN.)

AT SLOPE

PPLICABLE

1 MAX. CUT

PIT

IR GUARD

AREA ONLY

ASIN - SLOPES

ASIN - LAWN

FINISH GRADE

I BLETS- 3"

iH GRADE

X

TEST

U

OUTLET

INLET

ONE CUBIC FT.

3/ 4" GRAVEL SUMP

DISC FILTER

DRIP ONLY)

BRICK SUPPORTS

4 REQ' D.)

SCH. 80 PVC

UNION

n REMOTE CONTROL

LY VALVE

BRASS NIPPLE

BRASS ELBOW-

PLASTIC BOX

WITH LOCKING COVER

HEAT BRAND ' Q. V.' 2" HIGH

NOTES:

1. TOP OF ROOT CONTROL BARRIER MUST BE AT GRADE ( NEVER BELOW GRADE).

2. POSITION ROOT CONTROL BARRIER AS CLOSE TO STRUCTURE AS POSSIBLE.

3. DURING CONSTRUCTION BARRIER CAN BE PLACED AGAINST INSIDE OF FORMS.

4. THE RAISED ROOT DEFLECTORS MUST BE FACING TOWARD THE TREE.

5. BARRIER TO EXTEND A MINIMUM OF Be BELOW BOTTOM OF HARDSCAPE.

6. FOR MOST TREES 10 - 12 FEET OF BARRIER WILL BE ADEQUATE.

RO(

BAR

BAC,., . w

4 ROOT BARRIER

L - 3

4" ' BLU - LOCK' FLEX PIPE

PIED 2" BELOW GRADE & SECURED

METAL STAPLES ® EACH EMITTER

R

INSIDE WALL

rll

INSIDE WALL MOUNT

OPTION - DASHED

i i

PLASTIC RECTANGULAR VALVE BOX W/

SHORT BRASS NIPPLE

OUTSIDE WALL

LOCKABLE COVER MARKED VALVE' &

r

HEAT BRAND VALVE STATION 2" HIGH.

PRESSURE REGULATOR

Y'

PLATE SECURED TO WALL

CHRISTY TAGS

QUICK COUPLING VALVE

W / MIN. OF 6 - 1/ 4" DIA.

REMOTE CONTROL SEE PLANS & SPECS)

PRESSURE REGULATOR

VALVE

POLY DRIP ONLY)

HEIGHT PER BRASS NIPPLE

AUTOMATIC IRRIGATION

LOCAL CODES)

STRONG BOX

OUTLET

INLET

ONE CUBIC FT.

3/ 4" GRAVEL SUMP

DISC FILTER

DRIP ONLY)

BRICK SUPPORTS

4 REQ' D.)

SCH. 80 PVC

UNION

n REMOTE CONTROL

LY VALVE

BRASS NIPPLE

BRASS ELBOW-

PLASTIC BOX

WITH LOCKING COVER

HEAT BRAND ' Q. V.' 2" HIGH

NOTES:

1. TOP OF ROOT CONTROL BARRIER MUST BE AT GRADE ( NEVER BELOW GRADE).

2. POSITION ROOT CONTROL BARRIER AS CLOSE TO STRUCTURE AS POSSIBLE.

3. DURING CONSTRUCTION BARRIER CAN BE PLACED AGAINST INSIDE OF FORMS.

4. THE RAISED ROOT DEFLECTORS MUST BE FACING TOWARD THE TREE.

5. BARRIER TO EXTEND A MINIMUM OF Be BELOW BOTTOM OF HARDSCAPE.

6. FOR MOST TREES 10 - 12 FEET OF BARRIER WILL BE ADEQUATE.

RO(

BAR

BAC,., . w

4 ROOT BARRIER

L - 3

4" ' BLU - LOCK' FLEX PIPE

PIED 2" BELOW GRADE & SECURED

METAL STAPLES ® EACH EMITTER

R

INSIDE WALL

rll

INSIDE WALL MOUNT

OPTION - DASHED

i i

REDUCED PRESSURE BACKFLOW SHORT BRASS NIPPLE

OUTSIDE WALL

i

J - BOX r

2 PLACES

PRESSURE REGULATOR

Y'

PLATE SECURED TO WALL SHORT BRASS NIPPLE

AND STRAINER UNITS

SEE IRRIGATION PLAN) W / MIN. OF 6 - 1/ 4" DIA.

RISER

ANCHOR BOLTS OR EQ. BRASS ELL

PROVIDE 3/ 4" ELEC. F

REDUCED PRESSURE BACKFLOW SHORT BRASS NIPPLE

OUTSIDE WALL PREVENTOR W / BALL VALVES

3/ 4" PLYWOOD MOUNTING AND TEST COCKS. PRESSURE REGULATOR

Y'

PLATE SECURED TO WALL SHORT BRASS NIPPLE

AND STRAINER UNITS

SEE IRRIGATION PLAN) W / MIN. OF 6 - 1/ 4" DIA.

RISER

ANCHOR BOLTS OR EQ. BRASS ELL

PAINT) HEIGHT PER BRASS NIPPLE

AUTOMATIC IRRIGATION

LOCAL CODES)

STRONG BOX

CONTROLLER I95% COMPACT O II S. S. ENCLOSURE

SUBGRADE

SEE LEGEND

4" CONC. I BRASS UNION

SLAB

TYPICAL

6"

3" MIN. DIA. SCH. 40 PVC PIPE

OR 2X DIA. OF WIRE BUNDLE'

TYP

PROVIDE 3/ 4" ELEC. FFIN. GIRD.

CONNECTION \

12" MIN.

FFLOW

FIN. GIRD.

TTHREADED BRASS

j j RRISER

ADAPTOR

THRUST BLOCK PVC COUPLING

TxS) TYP.

BRASS ELLS TYP. (

ONTROL WIRE BUNDLE

SHORT BRASS

OR FOOTING AND TAPE ( 10' O. C.)

NIPPLE TYP

LL

5 CONTROLLER

L - 3 WALL MOUNT

BOWSMITH EMITTER W/ SPAGHETTI

TUBING & BUG CAP TYP

TUBING SHALL BE 1. 5' MAXIMUM LENGTH

RIANGULAR SPACED SHRUBS,

EE PLANTING PLANS FOR

fPE AND SPACING

3/ 4" ' BLU - LOCK' PURPLE FLEX

PIPE TYP.

INSTALL PARALLEL TO SLOPE FACE

BOWSMITH EMITTER W/ SPAGHETTI

TUBING & BUG CAP TYP - 3 EMITTERS

SHALL BE INSTALLED PER TREE

TUBING SHALL BE 1. 5' MAXIMUM LENGTH

TREE PLANTING PER PLANTING PLANS

MIN. 3 STAINLESS STL. NOTE:

HOSE CLAMPS NOTE:

ONE CU. FT., 3/ 4" GRAVEL

DRIP EMITTER SHALL BE PLACED TO DRIP DIRECTLY ADJACENT TO PLANT ROOTBALL. DRIP EMITTERS SHALL BE PLACED TO DRIP DIRECTLY ADJACENT TO TREE ROOTBALL.

ALL IRRIGATION PIPING SHALL BE INSTALLED PRIOR TO PLANT LAYOUTS.

SUPPLY LINE

B

36" # 4 REBAR LATERAL SUPPLY LINES SHALL RUN PARALLEL TO SLOPE WITH DRIP EMITTER

PRES. SUPPLY LINE FITTING

LINES RUN PERPENDICULAR TO SLOPE AS SHOWN ABOVE.

BRICK SUPPORTS( 3 REQ' D.) ALL IRRIGATION PIPING SHALL BE INSTALLED PRIOR TO PLANT LAYOUTS.

o OUICK COUPLER DRIP EMITTER 2 TREE DRIP LAYOUT

L - 3 - 3 ASSEMBLY DETAIL

L - 3

O PVC EXHAUST HEADER 10 SUB — SURFACE DRIPUNE:

1 2 3 4 5 OBLULOCK TEE OR EL ( TYPICAL) POTABLE: XFS

DRIPUNERIPUNE (

TYPICAL)

NON — POTABLE: XFSP DRIPUNE

r ____ _____

O3 BARB X MALE FITTING: 11 )¢" POLYETHYLENE BLANK TUBING:

RAIN BIRD XFD —MA FITTING ( TYPICAL) RAIN BIRD XF SERIES BLANK TUBING

FP

OFLUSH POINT ( TYPICAL) 12 BARB X BARB INSERT TEE OR CROSS:

SEE RAIN BIRD DETAIL " XFS FLUSH POINT" OR " XFS RAIN BIRD XFD —TEE OR

FLUSH POINT WITH BALL VALVE" RAIN BIRD XFD —CROSS ( TYPICAL)

O PERIMETER Of AREA 13 AIR RELIEF VALVE:

RAIN BIRD AR VALVE KIT

O PERIMETER DRIPLINE PIPE TO BE INSTALLED 2 " -4" SEE RAIN BIRD DETAIL ' XFS AIR RELIEF VALVE KIT" 2"- 4

FROM PERIMETER OF AREA OR " XFS AIR REUEF VALVE KIT IN PVC HEADER"

O PVC SUPPLY PIPE FROM RAIN BIRD CONTROL ZONE 14 BARB X FEMALE FITTING:

KIT ( SIZED TO MEET LATERAL FLOW DEMAND) RAIN BIRD XFD —TFA - 075 FITTING

O BLULOCK SUPPLY MANIFOLD 15 X" PVC NIPPLE, LENGTH AS NECESSARY

Q r.N O CONNECTION FRO

SEE

PLY MANIFOLD TO DRIPUNE

NOTES:

1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE,

PLANT MATERIALS AND CHANGES IN ELEVATION. SEE RAIN BIRD XF — SDI DRIPUNE

INSTALLATION GUIDE FOR SUGGESTED SPACINGS.

2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM LENGTH

SHOWN IN THE ACCOMPANYING TABLE.

3. AIR RELIEF VALVE TO BE INSTALLED AT HIGH POINT OF AREA.

XFS SUB - SURFACE DRIPLINE

N. T. S.

XFS Dripline Center Feed Layout. dwg

CENTER FEED LAYOUT

INSET A

XFS Dripline Maxitrxxn Lateral Length$ ( Feet)

12" Spacing 18" Spacing 24" Spacing

Inlet Pressure Nominal Flow ( GPH) Nominal Flow ( GPH) Nominal Flow ( GPH) psi 0. 6 1 0. 9 0. 6 0. 9 0. 6 0. 9

15 255 194 357 273 448 343

20 291 220 408 313 514 394

30 350 266 494 378 622 478

40 396 302 560 428 705 541

50 434 333 1 614 1 470 1 775 1 594

10 - 27 - 10

O EASY FIT COMPRESSION TEE:

4 "— 6" /

RAIN BIRD MDCF EE

O SUB— SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

O3 INUNE DRIP EMITTER

1 2 3 4

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF/ FINISH GRADE OR SHRUB BED

WITH MULCH

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB- SURFACE DRIPLINE BURIAL 10 - 27 - 10

N. T. S.

XFS Dripline Burial. dwg b

O FINISH GRADE

O SUBTERRANEAN EMITTER BOX:

RAIN BIRD SEB 7XB

O AIR/ VACUUM RELIEF VALVE KIT.

RAIN BIRD AR VALVE KIT

TO BE INSTALLED AT HIGH POINT IN

DRIP ZONE

FINISH GRADE

O5 BLULOCK TEE

BLULOCK HEADER PIPE

O BRICK ( 1 OF 2)

O 3" MINIMUM DEPTH OF

WASHED GRAVEL

s REDUCED PRESSURE

L - 3 BACKFLOW PREVENTER

FINISH GRADE PURPLE ROUND PLASTIC VALVE

BOX W/ PURPLE LOCKING COVER

IITII

II

3 END FLUSH CAP

L - 3

REVISED

NOS:

LOCKABLE COVER PVC VALVE W/ WIRE FROM MODULE TO SENSOR SHALL BE 16/ 2. USE

MARKED ' WATER' CROSS HANDLE CONTROLLER SMART PORT TO CONNECT TO MODULE UNIT.

VALVE BOX, W / EXTENSIONS UN

ON80

PVC

AS REQUIRED

12" MIN. FLUSH IN LAWN

FINISH GRADE 2" IN GROUND UP M 1W AWAY MODEL ET SYSTEM SENSOR

COVER ( OPTIONAL ET WIND NOT SHOWN)

INSTALL ON THE ROOF AND

ATTACH TO PARAPET.

CIL \/

SCH. 80 PVC

EDGE OF FIXED o W /

NIPPLE M

IMPROVEMENTS M( N COUPLING ( SxT) CONDUIT FROM ET SYSTEM O

SENSOR

FLOW °

p ° "` MODELET SYSTEMMODU

LL O

MOUNT LESS THAN 6' AWAY W CD co

INLET FITTINGS PVC FROM CONTROLLER /' 11 Z O

TYP. TO

OUTLj PIE COMPATIBLE HUNTER CONTROLR:

FITTINGS

L` 0 04 Z

O X i \

SRC, PRO - C, ICC, ACC I Z ' Q

g L2" MIN., 4" MAX. i \

BRICK SUPPORTS COMMUNICATION WIRE FROM

3 REQ D.) SENSOR TO MODULE U 0 N

95% COMPACTED ' POWER SOURCE W N 0 cV O -C

SUBGRADE

R — `

NE CUBIC

R ( ) _ Q) LJ Z

0 CD

MIN. 3/ 4' GRAVEL /

SUMP U ( n O Cn

BALL VALVE —

v

L - 3 1, I) ET SYSTEM m LlJ o °:

L- 3 a

Q L_ z - O

Q p O LO jj 04

V) Q

LLJ

J ZO ( 0(

ag CW

U

I(D

NATURAL GRAY CONCRETE

SMOOTH TROWEL FINISH

PLANTER GRADE

TYP.

3 REBAR CONTINUOUS

6' MAX. HEIGHT

4 MOW CURB DETAIL

L - 3

1" RADIUS

TURF TYP.

O SUB — SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

xj1 \ i \ i I I \1Ii / / i / /i 4 "— 6"

O INUNE DRIP EMITTER OUTLET

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF / FINISH GRADE OR SHRUB BED

WITH MULCH

1 2 3

O RATCHET CLAMP ( INCLUDED WITH

ADAPTER)

O INSERT ADAPTER FOR BLULOCK PIPE:

5 RAIN BIRD XFD — INVPC

O O7 BLULOCK LATERAL PIPE

MAXIMUM 1" IN DIAMETER

71 DEPTH PER SPECIFICATION

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB - SURFACE DRIPLINE INSERT 10 - 27 - 10

J N. T. S.

ADAPTER FOR 1" OR LARGER PVC

XFS Dripline Adapter tar PVC. dwg

AS - BUILT NOTE

ALHAMBRA GROUP LANDSCAPE ARCHITECTS PROVIDES NO

WARRANTY OR GUARANTEE AS TO THE ACCURACY OR

COMPLETENESS OF THE AS - BUILT INFORMATION PROVIDED

ON THE PLANS & SPECIFICATIONS SINCE ALL INFORMATION

COMPILED HEREIN HAS BEEN PROVIDED BY OTHER PARTIES.

AS - BUILT

XFMOM

RFACE DRIPLINE

1s

UUMRELIEFVALVEKITINPVCHEADER PLANTING AND IRRIGATION DETAILS

XFS Air Vacuum Relief Vale Kit In PVC Header. dwg

ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF ALHAMBRA GROUP LANDSCAPE ARCHITECTS & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ARCHITECTS. ANY CHANGE MADE BY PARTIES OTHER THAN SAID ARCHITECTS SHALL RELIEVE ARCHITECTS OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE ARCHITECT.

G\ jECT b QQ 2017 % y d0 a Q

U) O I I U s10321

5A\ P

Z W H

Q

W W

Z W

W

U

V

Z

Z

Z Q W O J U

LO_

Z W N

Q Q U

Q Q ° oLL Z = Z

I. L Cr

W W

M Z W W

QZ

Q M

Z

W co ce) ( n

U W

W Z

O drawn: V. D.

checked: V. D.

date: 08- 19- 11

SHEET

L - 3 of 4 sheets

JOB NO.

11 - 101

NOTES:

1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE,

PLANT MATERIALS AND CHANGES IN ELEVATION. SEE RAIN BIRD XF — SDI DRIPUNE

INSTALLATION GUIDE FOR SUGGESTED SPACINGS.

2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM LENGTH

SHOWN IN THE ACCOMPANYING TABLE.

3. AIR RELIEF VALVE TO BE INSTALLED AT HIGH POINT OF AREA.

XFS SUB - SURFACE DRIPLINE

N. T. S.

XFS Dripline Center Feed Layout. dwg

CENTER FEED LAYOUT

INSET A

XFS Dripline Maxitrxxn Lateral Length$ ( Feet)

12" Spacing 18" Spacing 24" Spacing

Inlet Pressure Nominal Flow ( GPH) Nominal Flow ( GPH) Nominal Flow ( GPH) psi 0. 6 1 0. 9 0. 6 0. 9 0. 6 0. 9

15 255 194 357 273 448 343

20 291 220 408 313 514 394

30 350 266 494 378 622 478

40 396 302 560 428 705 541

50 434 333 1 614 1 470 1 775 1 594

10 - 27 - 10

O EASY FIT COMPRESSION TEE:

4 "— 6" /

RAIN BIRD MDCF EE

O SUB— SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

O3 INUNE DRIP EMITTER

1 2 3 4

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF/ FINISH GRADE OR SHRUB BED

WITH MULCH

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB- SURFACE DRIPLINE BURIAL 10 - 27 - 10

N. T. S.

XFS Dripline Burial. dwg b

O FINISH GRADE

O SUBTERRANEAN EMITTER BOX:

RAIN BIRD SEB 7XB

O AIR/ VACUUM RELIEF VALVE KIT.

RAIN BIRD AR VALVE KIT

TO BE INSTALLED AT HIGH POINT IN

DRIP ZONE

FINISH GRADE

O5 BLULOCK TEE

BLULOCK HEADER PIPE

O BRICK ( 1 OF 2)

O 3" MINIMUM DEPTH OF

WASHED GRAVEL

s REDUCED PRESSURE

L - 3 BACKFLOW PREVENTER

FINISH GRADE PURPLE ROUND PLASTIC VALVE

BOX W/ PURPLE LOCKING COVER

IITII

II

3 END FLUSH CAP

L - 3

REVISED

NOS:

LOCKABLE COVER PVC VALVE W/ WIRE FROM MODULE TO SENSOR SHALL BE 16/ 2. USE

MARKED ' WATER' CROSS HANDLE CONTROLLER SMART PORT TO CONNECT TO MODULE UNIT.

VALVE BOX, W / EXTENSIONS UN

ON80

PVC

AS REQUIRED

12" MIN. FLUSH IN LAWN

FINISH GRADE 2" IN GROUND UP M 1W AWAY MODEL ET SYSTEM SENSOR

COVER ( OPTIONAL ET WIND NOT SHOWN)

INSTALL ON THE ROOF AND

ATTACH TO PARAPET.

CIL \/

SCH. 80 PVC

EDGE OF FIXED o W /

NIPPLE M

IMPROVEMENTS M( N COUPLING ( SxT) CONDUIT FROM ET SYSTEM O

SENSOR

FLOW °

p ° "` MODELET SYSTEMMODU

LL O

MOUNT LESS THAN 6' AWAY W CD co

INLET FITTINGS PVC FROM CONTROLLER /' 11 Z O

TYP. TO

OUTLj PIE COMPATIBLE HUNTER CONTROLR:

FITTINGS

L` 0 04 Z

O X i \

SRC, PRO - C, ICC, ACC I Z ' Q

g L2" MIN., 4" MAX. i \

BRICK SUPPORTS COMMUNICATION WIRE FROM

3 REQ D.) SENSOR TO MODULE U 0 N

95% COMPACTED ' POWER SOURCE W N 0 cV O -C

SUBGRADE

R — `

NE CUBIC

R ( ) _ Q) LJ Z

0 CD

MIN. 3/ 4' GRAVEL /

SUMP U ( n O Cn

BALL VALVE —

v

L - 3 1, I) ET SYSTEM m LlJ o °:

L- 3 a

Q L_ z - O

Q p O LO jj 04

V) Q

LLJ

J ZO ( 0(

ag CW

U

I( D

NATURAL GRAY CONCRETE

SMOOTH TROWEL FINISH

PLANTER GRADE

TYP.

3 REBAR CONTINUOUS

6' MAX. HEIGHT

4 MOW CURB DETAIL

L - 3

1" RADIUS

TURF TYP.

O SUB — SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

xj1 \ i \ i I I \ 1Ii / /i / /i 4 "— 6"

O INUNE DRIP EMITTER OUTLET

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF / FINISH GRADE OR SHRUB BED

WITH MULCH

1 2 3

O RATCHET CLAMP ( INCLUDED WITH

ADAPTER)

O INSERT ADAPTER FOR BLULOCK PIPE:

5 RAIN BIRD XFD — INVPC

O O7 BLULOCK LATERAL PIPE

MAXIMUM 1" IN DIAMETER

71 DEPTH PER SPECIFICATION

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB - SURFACE DRIPLINE INSERT 10 - 27 - 10

J N. T. S.

ADAPTER FOR 1" OR LARGER PVC

XFS Dripline Adapter tar PVC. dwg

AS - BUILT NOTE

ALHAMBRA GROUP LANDSCAPE ARCHITECTS PROVIDES NO

WARRANTY OR GUARANTEE AS TO THE ACCURACY OR

COMPLETENESS OF THE AS - BUILT INFORMATION PROVIDED

ON THE PLANS & SPECIFICATIONS SINCE ALL INFORMATION

COMPILED HEREIN HAS BEEN PROVIDED BY OTHER PARTIES.

AS - BUILT

XFMOM

RFACE DRIPLINE

1s

UUMRELIEFVALVEKITINPVCHEADER PLANTING AND IRRIGATION DETAILS

XFS Air Vacuum Relief Vale Kit In PVC Header. dwg

ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF ALHAMBRA GROUP LANDSCAPE ARCHITECTS & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ARCHITECTS. ANY CHANGE MADE BY PARTIES OTHER THAN SAID ARCHITECTS SHALL RELIEVE ARCHITECTS OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE ARCHITECT.

G\ jECT b QQ 2017 % y d0 a Q

U) O I I U s10321

5A\ P

Z W H

Q

W W

Z W

W

U

V

Z

Z

Z Q W O J U

LO_

Z W N

Q Q U

Q Q ° oLL Z = Z

I. L Cr

W W

M Z W W

QZ

Q M

Z

W co ce) ( n

U W

W Z

O drawn: V. D.

checked: V. D.

date: 08- 19- 11

SHEET

L - 3 of 4 sheets

JOB NO.

11 - 101

10 - 27 - 10

O EASY FIT COMPRESSION TEE:

4 "— 6" /

RAIN BIRD MDCF EE

O SUB— SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

O3 INUNE DRIP EMITTER

1 2 3 4

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF/ FINISH GRADE OR SHRUB BED

WITH MULCH

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE —DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB- SURFACE DRIPLINE BURIAL 10 - 27 - 10

N. T. S.

XFS Dripline Burial. dwg b

O FINISH GRADE

O SUBTERRANEAN EMITTER BOX:

RAIN BIRD SEB 7XB

O AIR/ VACUUM RELIEF VALVE KIT.

RAIN BIRD AR VALVE KIT

TO BE INSTALLED AT HIGH POINT IN

DRIP ZONE

FINISH GRADE

O5 BLULOCK TEE

BLULOCK HEADER PIPE

O BRICK ( 1 OF 2)

O 3" MINIMUM DEPTH OF

WASHED GRAVEL

s REDUCED PRESSURE

L - 3 BACKFLOW PREVENTER

FINISH GRADE PURPLE ROUND PLASTIC VALVE

BOX W/ PURPLE LOCKING COVER

IITII

II

3 END FLUSH CAP

L - 3

REVISED

NOS:

LOCKABLE COVER PVC VALVE W/ WIRE FROM MODULE TO SENSOR SHALL BE 16/ 2. USE

MARKED ' WATER' CROSS HANDLE CONTROLLER SMART PORT TO CONNECT TO MODULE UNIT.

VALVE BOX, W / EXTENSIONS UN

ON80

PVC

AS REQUIRED

12" MIN. FLUSH IN LAWN

FINISH GRADE 2" IN GROUND UP M 1W AWAY MODEL ET SYSTEM SENSOR

COVER ( OPTIONAL ET WIND NOT SHOWN)

INSTALL ON THE ROOF AND

ATTACH TO PARAPET.

CIL \/

SCH. 80 PVC

EDGE OF FIXED o W /

NIPPLE M

IMPROVEMENTS M( N COUPLING ( SxT) CONDUIT FROM ET SYSTEM O

SENSOR

FLOW °

p ° "` MODELET SYSTEMMODU

LL O

MOUNT LESS THAN 6' AWAY W CD co

INLET FITTINGS PVC FROM CONTROLLER /' 11 Z O

TYP. TO

OUTLj PIE COMPATIBLE HUNTER CONTROLR:

FITTINGS

L` 0 04 Z

O X i \

SRC, PRO - C, ICC, ACC I Z ' Q

g L2" MIN., 4" MAX. i \

BRICK SUPPORTS COMMUNICATION WIRE FROM

3 REQ D.) SENSOR TO MODULE U 0 N

95% COMPACTED ' POWER SOURCE W N 0 cV O -C

SUBGRADE

R — `

NE CUBIC

R ( ) _ Q) LJ Z

0 CD

MIN. 3/ 4' GRAVEL /

SUMP U ( n O Cn

BALL VALVE —

v

L - 3 1, I) ET SYSTEM m LlJ o °:

L- 3 a

Q L_ z - O

Q p O LO jj 04

V) Q

LLJ

J ZO ( 0(

ag CW

U

I(D

NATURAL GRAY CONCRETE

SMOOTH TROWEL FINISH

PLANTER GRADE

TYP.

3 REBAR CONTINUOUS

6' MAX. HEIGHT

4 MOW CURB DETAIL

L - 3

1" RADIUS

TURF TYP.

O SUB — SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

xj1 \ i \ i I I \1Ii / / i / /i 4 "— 6"

O INUNE DRIP EMITTER OUTLET

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF / FINISH GRADE OR SHRUB BED

WITH MULCH

1 2 3

O RATCHET CLAMP ( INCLUDED WITH

ADAPTER)

O INSERT ADAPTER FOR BLULOCK PIPE:

5 RAIN BIRD XFD — INVPC

O O7 BLULOCK LATERAL PIPE

MAXIMUM 1" IN DIAMETER

71 DEPTH PER SPECIFICATION

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB - SURFACE DRIPLINE INSERT 10 - 27 - 10

J N. T. S.

ADAPTER FOR 1" OR LARGER PVC

XFS Dripline Adapter tar PVC. dwg

AS - BUILT NOTE

ALHAMBRA GROUP LANDSCAPE ARCHITECTS PROVIDES NO

WARRANTY OR GUARANTEE AS TO THE ACCURACY OR

COMPLETENESS OF THE AS - BUILT INFORMATION PROVIDED

ON THE PLANS & SPECIFICATIONS SINCE ALL INFORMATION

COMPILED HEREIN HAS BEEN PROVIDED BY OTHER PARTIES.

AS - BUILT

XFMOM

RFACE DRIPLINE

1s

UUMRELIEFVALVEKITINPVCHEADER PLANTING AND IRRIGATION DETAILS

XFS Air Vacuum Relief Vale Kit In PVC Header. dwg

ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF ALHAMBRA GROUP LANDSCAPE ARCHITECTS & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ARCHITECTS. ANY CHANGE MADE BY PARTIES OTHER THAN SAID ARCHITECTS SHALL RELIEVE ARCHITECTS OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE ARCHITECT.

G\ jECT b QQ 2017 % y d0 a Q

U) O I I U s10321

5A\ P

Z W H

Q

W W

Z W

W

U

V

Z

Z

Z Q W O J U

LO_

Z W N

Q Q U

Q Q ° oLL Z = Z

I. L Cr

W W

M Z W W

QZ

Q M

Z

W co ce) ( n

U W

W Z

O drawn: V. D.

checked: V. D.

date: 08- 19- 11

SHEET

L - 3 of 4 sheets

JOB NO.

11 - 101 b

O FINISH GRADE

O SUBTERRANEAN EMITTER BOX:

RAIN BIRD SEB 7XB

O AIR/ VACUUM RELIEF VALVE KIT.

RAIN BIRD AR VALVE KIT

TO BE INSTALLED AT HIGH POINT IN

DRIP ZONE

FINISH GRADE

O5 BLULOCK TEE

BLULOCK HEADER PIPE

O BRICK ( 1 OF 2)

O 3" MINIMUM DEPTH OF

WASHED GRAVEL

s REDUCED PRESSURE

L - 3 BACKFLOW PREVENTER

FINISH GRADE PURPLE ROUND PLASTIC VALVE

BOX W/ PURPLE LOCKING COVER

IITII

II

3 END FLUSH CAP

L - 3

REVISED

NOS:

LOCKABLE COVER PVC VALVE W/ WIRE FROM MODULE TO SENSOR SHALL BE 16/ 2. USE

MARKED ' WATER' CROSS HANDLE CONTROLLER SMART PORT TO CONNECT TO MODULE UNIT.

VALVE BOX, W / EXTENSIONS UN

ON80

PVC

AS REQUIRED

12" MIN. FLUSH IN LAWN

FINISH GRADE 2" IN GROUND UP M 1W AWAY MODEL ET SYSTEM SENSOR

COVER ( OPTIONAL ET WIND NOT SHOWN)

INSTALL ON THE ROOF AND

ATTACH TO PARAPET.

CIL \/

SCH. 80 PVC

EDGE OF FIXED o W /

NIPPLE M

IMPROVEMENTS M( N COUPLING ( SxT) CONDUIT FROM ET SYSTEM O

SENSOR

FLOW °

p ° "` MODELET SYSTEMMODU

LL O

MOUNT LESS THAN 6' AWAY W CD co

INLET FITTINGS PVC FROM CONTROLLER /' 11 Z O

TYP. TO

OUTLj PIE COMPATIBLE HUNTER CONTROLR:

FITTINGS

L` 0 04 Z

O X i \

SRC, PRO - C, ICC, ACC I Z ' Q

g L2" MIN., 4" MAX. i \

BRICK SUPPORTS COMMUNICATION WIRE FROM

3 REQ D.) SENSOR TO MODULE U 0 N

95% COMPACTED ' POWER SOURCE W N 0 cV O -C

SUBGRADE

R — `

NE CUBIC

R ( ) _ Q) LJ Z

0 CD

MIN. 3/ 4' GRAVEL /

SUMP U ( n O Cn

BALL VALVE —

v

L - 3 1, I) ET SYSTEM m LlJ o °:

L- 3 a

Q L_ z - O

Q p O LO jj 04

V) Q

LLJ

J ZO ( 0(

ag CW

U

I( D

NATURAL GRAY CONCRETE

SMOOTH TROWEL FINISH

PLANTER GRADE

TYP.

3 REBAR CONTINUOUS

6' MAX. HEIGHT

4 MOW CURB DETAIL

L - 3

1" RADIUS

TURF TYP.

O SUB — SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

xj1 \ i \ i I I \ 1Ii / /i / /i 4 "— 6"

O INUNE DRIP EMITTER OUTLET

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF / FINISH GRADE OR SHRUB BED

WITH MULCH

1 2 3

O RATCHET CLAMP ( INCLUDED WITH

ADAPTER)

O INSERT ADAPTER FOR BLULOCK PIPE:

5 RAIN BIRD XFD — INVPC

O O7 BLULOCK LATERAL PIPE

MAXIMUM 1" IN DIAMETER

71 DEPTH PER SPECIFICATION

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB - SURFACE DRIPLINE INSERT 10 - 27 - 10

J N. T. S.

ADAPTER FOR 1" OR LARGER PVC

XFS Dripline Adapter tar PVC. dwg

AS - BUILT NOTE

ALHAMBRA GROUP LANDSCAPE ARCHITECTS PROVIDES NO

WARRANTY OR GUARANTEE AS TO THE ACCURACY OR

COMPLETENESS OF THE AS - BUILT INFORMATION PROVIDED

ON THE PLANS & SPECIFICATIONS SINCE ALL INFORMATION

COMPILED HEREIN HAS BEEN PROVIDED BY OTHER PARTIES.

AS - BUILT

XFMOM

RFACE DRIPLINE

1s

UUMRELIEFVALVEKITINPVCHEADER PLANTING AND IRRIGATION DETAILS

XFS Air Vacuum Relief Vale Kit In PVC Header. dwg

ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF ALHAMBRA GROUP LANDSCAPE ARCHITECTS & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ARCHITECTS. ANY CHANGE MADE BY PARTIES OTHER THAN SAID ARCHITECTS SHALL RELIEVE ARCHITECTS OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE ARCHITECT.

G\ jECT b QQ 2017 % y d0 a Q

U) O I I U s10321

5A\ P

Z W H

Q

W W

Z W

W

U

V

Z

Z

Z Q W O J U

LO_

Z W N

Q Q U

Q Q ° oLL Z = Z

I. L Cr

W W

M Z W W

QZ

Q M

Z

W co ce) ( n

U W

W Z

O drawn: V. D.

checked: V. D.

date: 08- 19- 11

SHEET

L - 3 of 4 sheets

JOB NO.

11 - 101 s REDUCED PRESSURE

L - 3 BACKFLOW PREVENTER

FINISH GRADE PURPLE ROUND PLASTIC VALVE

BOX W/ PURPLE LOCKING COVER

IITII

II

3 END FLUSH CAP

L - 3

REVISED

NOS:

LOCKABLE COVER PVC VALVE W/ WIRE FROM MODULE TO SENSOR SHALL BE 16/ 2. USE

MARKED ' WATER' CROSS HANDLE CONTROLLER SMART PORT TO CONNECT TO MODULE UNIT.

VALVE BOX, W / EXTENSIONS UN

ON80

PVC

AS REQUIRED

12" MIN. FLUSH IN LAWN

FINISH GRADE 2" IN GROUND UP M 1W AWAY MODEL ET SYSTEM SENSOR

COVER ( OPTIONAL ET WIND NOT SHOWN)

INSTALL ON THE ROOF AND

ATTACH TO PARAPET.

CIL \/

SCH. 80 PVC

EDGE OF FIXED o W /

NIPPLE M

IMPROVEMENTS M( N COUPLING ( SxT) CONDUIT FROM ET SYSTEM O

SENSOR

FLOW °

p ° "` MODELET SYSTEMMODU

LL O

MOUNT LESS THAN 6' AWAY W CD co

INLET FITTINGS PVC FROM CONTROLLER /' 11 Z O

TYP. TO

OUTLj PIE COMPATIBLE HUNTER CONTROLR:

FITTINGS

L` 0 04 Z

O X i \

SRC, PRO - C, ICC, ACC I Z ' Q

g L2" MIN., 4" MAX. i \

BRICK SUPPORTS COMMUNICATION WIRE FROM

3 REQ D.) SENSOR TO MODULE U 0 N

95% COMPACTED ' POWER SOURCE W N 0 cV O -C

SUBGRADE

R — `

NE CUBIC

R ( ) _ Q) LJ Z

0 CD

MIN. 3/ 4' GRAVEL /

SUMP U ( n O Cn

BALL VALVE —

v

L - 3 1, I) ET SYSTEM m LlJ o °:

L- 3 a

Q L_ z - O

Q p O LO jj 04

V) Q

LLJ

J ZO ( 0(

ag CW

U

I(D

NATURAL GRAY CONCRETE

SMOOTH TROWEL FINISH

PLANTER GRADE

TYP.

3 REBAR CONTINUOUS

6' MAX. HEIGHT

4 MOW CURB DETAIL

L - 3

1" RADIUS

TURF TYP.

O SUB — SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

xj1 \ i \ i I I \1Ii / / i / /i 4 "— 6"

O INUNE DRIP EMITTER OUTLET

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF / FINISH GRADE OR SHRUB BED

WITH MULCH

1 2 3

O RATCHET CLAMP ( INCLUDED WITH

ADAPTER)

O INSERT ADAPTER FOR BLULOCK PIPE:

5 RAIN BIRD XFD — INVPC

O O7 BLULOCK LATERAL PIPE

MAXIMUM 1" IN DIAMETER

71 DEPTH PER SPECIFICATION

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB - SURFACE DRIPLINE INSERT 10 - 27 - 10

J N. T. S.

ADAPTER FOR 1" OR LARGER PVC

XFS Dripline Adapter tar PVC. dwg

AS - BUILT NOTE

ALHAMBRA GROUP LANDSCAPE ARCHITECTS PROVIDES NO

WARRANTY OR GUARANTEE AS TO THE ACCURACY OR

COMPLETENESS OF THE AS - BUILT INFORMATION PROVIDED

ON THE PLANS & SPECIFICATIONS SINCE ALL INFORMATION

COMPILED HEREIN HAS BEEN PROVIDED BY OTHER PARTIES.

AS - BUILT

XFMOM

RFACE DRIPLINE

1s

UUMRELIEFVALVEKITINPVCHEADER PLANTING AND IRRIGATION DETAILS

XFS Air Vacuum Relief Vale Kit In PVC Header. dwg

ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF ALHAMBRA GROUP LANDSCAPE ARCHITECTS & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ARCHITECTS. ANY CHANGE MADE BY PARTIES OTHER THAN SAID ARCHITECTS SHALL RELIEVE ARCHITECTS OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE ARCHITECT.

G\ jECT b QQ 2017 % y d0 a Q

U) O I I U s10321

5A\ P

Z W H

Q

W W

Z W

W

U

V

Z

Z

Z Q W O J U

LO_

Z W N

Q Q U

Q Q ° oLL Z = Z

I. L Cr

W W

M Z W W

QZ

Q M

Z

W co ce) ( n

U W

W Z

O drawn: V. D.

checked: V. D.

date: 08- 19- 11

SHEET

L - 3 of 4 sheets

JOB NO.

11 - 101

3 END FLUSH CAP

L - 3

REVISED

NOS:

LOCKABLE COVER PVC VALVE W/ WIRE FROM MODULE TO SENSOR SHALL BE 16/ 2. USE

MARKED ' WATER' CROSS HANDLE CONTROLLER SMART PORT TO CONNECT TO MODULE UNIT.

VALVE BOX, W / EXTENSIONS UN

ON80

PVC

AS REQUIRED

12" MIN. FLUSH IN LAWN

FINISH GRADE 2" IN GROUND UP M 1W AWAY MODEL ET SYSTEM SENSOR

COVER ( OPTIONAL ET WIND NOT SHOWN)

INSTALL ON THE ROOF AND

ATTACH TO PARAPET.

CIL \/

SCH. 80 PVC

EDGE OF FIXED o W /

NIPPLE M

IMPROVEMENTS M( N COUPLING ( SxT) CONDUIT FROM ET SYSTEM O

SENSOR

FLOW °

p ° "` MODELET SYSTEMMODU

LL O

MOUNT LESS THAN 6' AWAY W CD co

INLET FITTINGS PVC FROM CONTROLLER /' 11 Z O

TYP. TO

OUTLj PIE COMPATIBLE HUNTER CONTROLR:

FITTINGS

L` 0 04 Z

O X i \

SRC, PRO - C, ICC, ACC I Z ' Q

g L2" MIN., 4" MAX. i \

BRICK SUPPORTS COMMUNICATION WIRE FROM

3 REQ D.) SENSOR TO MODULE U 0 N

95% COMPACTED ' POWER SOURCE W N 0 cV O -C

SUBGRADE

R — `

NE CUBIC

R ( ) _ Q) LJ Z

0 CD

MIN. 3/ 4' GRAVEL /

SUMP U ( n O Cn

BALL VALVE —

v

L - 3 1, I) ET SYSTEM m LlJ o °:

L- 3 a

Q L_ z - O

Q p O LO jj 04

V) Q

LLJ

J ZO ( 0(

ag CW

U

I( D

NATURAL GRAY CONCRETE

SMOOTH TROWEL FINISH

PLANTER GRADE

TYP.

3 REBAR CONTINUOUS

6' MAX. HEIGHT

4 MOW CURB DETAIL

L - 3

1" RADIUS

TURF TYP.

O SUB — SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

xj1 \ i \ i I I \ 1Ii / /i / /i 4 "— 6"

O INUNE DRIP EMITTER OUTLET

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF / FINISH GRADE OR SHRUB BED

WITH MULCH

1 2 3

O RATCHET CLAMP ( INCLUDED WITH

ADAPTER)

O INSERT ADAPTER FOR BLULOCK PIPE:

5 RAIN BIRD XFD — INVPC

O O7 BLULOCK LATERAL PIPE

MAXIMUM 1" IN DIAMETER

71 DEPTH PER SPECIFICATION

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB - SURFACE DRIPLINE INSERT 10 - 27 - 10

J N. T. S.

ADAPTER FOR 1" OR LARGER PVC

XFS Dripline Adapter tar PVC. dwg

AS - BUILT NOTE

ALHAMBRA GROUP LANDSCAPE ARCHITECTS PROVIDES NO

WARRANTY OR GUARANTEE AS TO THE ACCURACY OR

COMPLETENESS OF THE AS - BUILT INFORMATION PROVIDED

ON THE PLANS & SPECIFICATIONS SINCE ALL INFORMATION

COMPILED HEREIN HAS BEEN PROVIDED BY OTHER PARTIES.

AS - BUILT

XFMOM

RFACE DRIPLINE

1s

UUMRELIEFVALVEKITINPVCHEADER PLANTING AND IRRIGATION DETAILS

XFS Air Vacuum Relief Vale Kit In PVC Header. dwg

ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF ALHAMBRA GROUP LANDSCAPE ARCHITECTS & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ARCHITECTS. ANY CHANGE MADE BY PARTIES OTHER THAN SAID ARCHITECTS SHALL RELIEVE ARCHITECTS OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE ARCHITECT.

G\ jECT b QQ 2017 % y d0 a Q

U) O I I U s10321

5A\ P

Z W H

Q

W W

Z W

W

U

V

Z

Z

Z Q W O J U

LO_

Z W N

Q Q U

Q Q ° oLL Z = Z

I. L Cr

W W

M Z W W

QZ

Q M

Z

W co ce) ( n

U W

W Z

O drawn: V. D.

checked: V. D.

date: 08- 19- 11

SHEET

L - 3 of 4 sheets

JOB NO.

11 - 101

NATURAL GRAY CONCRETE

SMOOTH TROWEL FINISH

PLANTER GRADE

TYP.

3 REBAR CONTINUOUS

6' MAX. HEIGHT

4 MOW CURB DETAIL

L - 3

1" RADIUS

TURF TYP.

O SUB — SURFACE DRIPUNE:

RAIN BIRD XF SERIES DRIPUNE

POTABLE: XFS DRIPUNE

NON — POTABLE: XFSP DRIPUNE

xj1 \i \iI I \1Ii / /i / /i 4 "— 6"

O INUNE DRIP EMITTER OUTLET

O TIE DOWN STAKE: RAIN BIRD TDS - 050

WITH BEND ( TYPICAL)

O TURF / FINISH GRADE OR SHRUB BED

WITH MULCH

1 2 3

O RATCHET CLAMP ( INCLUDED WITH

ADAPTER)

O INSERT ADAPTER FOR BLULOCK PIPE:

5 RAIN BIRD XFD —INVPC

O O7 BLULOCK LATERAL PIPE

MAXIMUM 1" IN DIAMETER

71 DEPTH PER SPECIFICATION

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB - SURFACE DRIPLINE INSERT 10 - 27 - 10

J N. T. S.

ADAPTER FOR 1" OR LARGER PVC

XFS Dripline Adapter tar PVC. dwg

AS - BUILT NOTE

ALHAMBRA GROUP LANDSCAPE ARCHITECTS PROVIDES NO

WARRANTY OR GUARANTEE AS TO THE ACCURACY OR

COMPLETENESS OF THE AS - BUILT INFORMATION PROVIDED

ON THE PLANS & SPECIFICATIONS SINCE ALL INFORMATION

COMPILED HEREIN HAS BEEN PROVIDED BY OTHER PARTIES.

AS - BUILT

XFMOM

RFACE DRIPLINE

1s

UUMRELIEFVALVEKITINPVCHEADER PLANTING AND IRRIGATION DETAILS

XFS Air Vacuum Relief Vale Kit In PVC Header. dwg

ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF ALHAMBRA GROUP LANDSCAPE ARCHITECTS & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ARCHITECTS. ANY CHANGE MADE BY PARTIES OTHER THAN SAID ARCHITECTS SHALL RELIEVE ARCHITECTS OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE ARCHITECT.

G\ jECT b QQ 2017 % y d0 a Q

U) O I I U s10321

5A\ P

Z W H

Q

W W

Z W

W

U

V

Z

Z

Z Q W O J U

LO_

Z W N

Q Q U

Q Q ° oLL Z = Z

I. L Cr

W W

M Z W W

QZ

Q M

Z

W co ce) ( n

U W

W Z

O drawn: V. D.

checked: V. D.

date: 08- 19- 11

SHEET

L - 3 of 4 sheets

JOB NO.

11 - 101

NOTES:

1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, FOUR FEET IN LOAM, AND

FIVE FEET IN CLAY.

2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR

ELBOWS, USE TIE — DOWN STAKES ON EACH LEG OF THE CHANGE OF

DIRECTION.

3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN

STAKES.

XFS SUB - SURFACE DRIPLINE INSERT 10 - 27 - 10

J N. T. S.

ADAPTER FOR 1" OR LARGER PVC

XFS Dripline Adapter tar PVC. dwg

AS - BUILT NOTE

ALHAMBRA GROUP LANDSCAPE ARCHITECTS PROVIDES NO

WARRANTY OR GUARANTEE AS TO THE ACCURACY OR

COMPLETENESS OF THE AS - BUILT INFORMATION PROVIDED

ON THE PLANS & SPECIFICATIONS SINCE ALL INFORMATION

COMPILED HEREIN HAS BEEN PROVIDED BY OTHER PARTIES.

AS - BUILT

XFMOM

RFACE DRIPLINE

1s

UUMRELIEFVALVEKITINPVCHEADER PLANTING AND IRRIGATION DETAILS

XFS Air Vacuum Relief Vale Kit In PVC Header. dwg

ALL IDEAS, DESIGNS, & ARRANGEMENTS REPRESENTED HEREON ARE THE PROPERTY OF ALHAMBRA GROUP LANDSCAPE ARCHITECTS & SHALL BE USED FOR THIS PROJECT ONLY EXCEPT WITH THE WRITTEN PERMISSION OF SAID ARCHITECTS. ANY CHANGE MADE BY PARTIES OTHER THAN SAID ARCHITECTS SHALL RELIEVE ARCHITECTS OF RESPONSIBILITY FOR THE FACILITY OR AFFECTED PORTION THEREOF. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF ANY WORK & SHALL REPORT ANY DISCREPANCY TO THE ARCHITECT.

G\ jECT b QQ 2017 % y d0 a Q

U) O I I U s10321

5A\ P

Z W H

Q

W W

Z W

W

U

V

Z

Z

Z Q W O J U

LO_

Z W N

Q Q U

Q Q ° oLL Z = Z

I. L Cr

W W

M Z W W

QZ

Q M

Z

W co ce) ( n

U W

W Z

O drawn: V. D.

checked: V. D.

date: 08- 19- 11

SHEET

L - 3 of 4 sheets

JOB NO.

11 - 101

File details come from the government source that posted it. Updated .