Addendum 1.pdf
PDF 461 KB Posted
- Solicitation number
- RFB 785 2700000190 3
- Issued by
- Harrison County, Kentucky
About this file
This addendum document modifies Invitation to Bid (RFB) No. RFB-109-27, issued by the Commonwealth of Kentucky Department for Facilities and Support Services Division of Engineering and Contract Administration, for the re-advertisement of RFB-158-25 for the Pennyrile Forest Beach Complex Repair and Upgrade project located at the Department of Parks facility in Dawson Springs, Kentucky. The project involves repair and upgrade work at the beach restroom building, with specifications and drawings originally dated September 8, 2026. A site visit was conducted on November 12, 2026, with all bidder questions due by 8:00 AM EST on November 23, 2026, to be addressed in a final addendum issued November 24, 2026. The addendum provides clarifications and modifications to the original specifications and drawings, addressing concrete sealing requirements, water heater pad specifications, louver openings, sill sealer requirements, joint flashing details, exterior wood stain systems, roofing material specifications, and electrical lighting fixture additions. Specific clarifications include confirmation that asphalt shingles (not metal roofing) are the required roofing system per Specification Section 07 31 13, concrete sealer specifications for interior and exterior applications, and the requirement for Tremco ExoAir 230 fluid-applied air barrier behind all new fiber-cement siding with six-inch minimum clearance from grade.
The addendum does not establish pricing terms, set-asides, incumbent information, or funding sources. Bidders are required to acknowledge receipt of this addendum by inserting its number on the official bid document. All work must comply with the specifications outlined in the contract documents and applicable manufacturer requirements. The document includes detailed electrical legends, lighting fixture schedules with specific manufacturer models and specifications, and general demolition notes that outline contractor responsibilities for site familiarization, equipment removal, proper disposal, and coordination with the owner regarding service disruptions. Additional requirements address occupancy sensor installations, lighting control wiring diagrams, and coordination protocols with the architect and owner for final installation details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_RFB_785_2700000190_3_SO_FORM.PDF | ||
| Final_RFB_785_2700000190_1_SO_FORM.PDF | ||
| Addendum 2.pdf | ||
| Final_RFB_785_2700000190_2_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-109-27
FOR: Re-Advertisement of RFB-158-25
Pennyrile Forest Beach Complex Repair/Upgrade Department of Parks Dawson Springs, Kentucky
DATE: November 18, 2026
RFB-785-2700000190
ADDENDUM NO. One (1)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to attached addendum for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-109-27 For: Re-Advertisement of RFB-158-25
Pennyrile Forest Beach Complex Repair/Upgrade Department of Parks Dawson Springs, Kentucky
Janis Wilhoite, Statewide Procurement Analyst II Division of Engineering and Contract Administration
Parks – Pennyrile Forest Beach Complex Repair/Upgrade Engineering File No. 670-CBRB-PF28-00 C/S Project No. 2422
RFB 109-27 Re-Ad of RFB 158-25
2026.11.17
Addendum No. 01 _
The original specifications and drawings dated RTA 09/08/2026 for the above referenced project are amended as noted in this Addendum.
Receipt of this Addendum shall be acknowledged by inserting its number in the space provided on the Official Bid Document for RFB 109-27.
GENERAL
1) A Site Visit took place on November 12, 2026.
a) All questions are due by 8:00 AM EST on November 23, 2026 for consideration in the last addendum to be issued November 24, 2026.
2) Please provide the specification for the concrete sealer (product/system, number of coats, and any other requirements) and delineate on the plans where it starts and stops, interior and exterior, so all bidders price the same scope.
a) The mechanical room floor is to be sealed. The chase space does not need to be sealed.
In Mechanical (Room Number 3), sealant to start at door opening and extend to face of 7 5/8” CMU wall with mop sink.
b) Add the following to Specification Section 03 30 00 Cast-in-Place Concrete Section 2.
i) A. Penetrating Concrete Sealer (For “SEALED CONCRETE” shown on Room Finish
Schedule on architectural drawings): Clear, chemically reactive, waterborne solution of inorganic silicate or siliconate materials and proprietary components; odorless; that penetrates, hardens, and densifies concrete surfaces.
(1) Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated in the Work include, but are not limited to, the following:
(a) BASF Corporation; Construction Systems.
(b) ChemMasters, Inc.
(c) Dayton Superior.
(d) Euclid Chemical Company.
(e) Kaufman Products, Inc.
(f) L&M Construction Chemicals, Inc.
(g) Metalcrete Industries.
(h) PROSOCO, Inc.
(i) SpecChem, LLC.
(j) W. R. Meadows, Inc.
c) Refer to Specification Section 03 30 00 Cast-in-Place Concrete Section 3.12.F.4 for application.
3) Water heater pad: length x width x thickness and reinforcing, confirm whether EWH-1 sits on a floor pad, and who furnishes and installs the pad (not stated on the drawings).
a) Water heater sits on 2’x2’ – 4” concrete pad. Provided by plumbing contractor. Water heater P&T valve drains to floor drain. Anchor water heater straps to wall. Expansion tank gets mounted as high as possible, secure to structure or wall.
4) Louver opening (GC framing information only): tag/model or rough opening width x height, elevation (bottom or centerline), quantity and locations (A301: Elevations A and B; M101: one plenum), whether it is in the ICF wall or the gable framing, and any buck, lintel, header, or framing at the opening.
a) Louver is a custom architectural louver. Refer to Specification Section 08 90 00.
Mechanical exhaust ductwork connects directly to the back of the architectural provided louver. Dimensions are on A301 elevations. Section 1 on M101 shows the ductwork connecting to the gable framing. Note that building code requires free area for cross ventilation in the attic since insulation is at the ceiling level. The ductwork connects to the louver and the remainder of that louver is open with an insect screen per detail G/A401 to achieve required free area.
5) Whether sill sealer is required under the wood top plate on the ICF wall and, if so, the product, thickness, and width.
a) Yes, as indicated in Specification Section 06 10 00 Rough Carpentry Section 2.7.A.
6) Joint flashing at vertical panel seams: profile, material (gauge/finish), and color; and the panel width and seam layout on the elevations.
a) See explanation on elevations on Item 13 in this Section.
b) Refer to manufacturer’s typical details. Specification Section 07 46 46 Fiber Cement Siding calls for a moderate contact joint. Wall Section A/A401 shows horizontal flashing.
c) Caulk vertical joints between panels as required per manufacturer’s recommendation.
d) Refer to Specification Section 05 50 00 Metal Fabrications for gauge and finish of materials.
7) Exterior 1x4 stained wood: stain system and product, number of coats, sheen, and color/opacity, and whether it also applies to the other exterior cedar/wood trim in Attachment A.
a) All exterior wood will receive the stain system outlined in Specification Section 09 91 00
Painting Section 3.6.F.1 for Stain and 3.6.F.2 for Paint. Section 06 20 13 Exterior Finish Carpentry calls out Exterior Trim in Section 2.3 and Lumber Soffits in Section 2.4.
8) Is Copper ProPress an allowable product?
a) Yes, copper pressure seal-joint fittings similar to Viega are allowed.
9) Fire extinguishers are called out in Specification Section 10 44 16 but not on the plans.
a) One 10 pound fire extinguisher in Mechanical room mounted on the wall. Location coordinated with Owner and Architect.
10) The architectural drawings (A301/A401) indicate asphalt shingles, while the bid form requests a metal roofing manufacturer. Can you confirm the intended roofing system?
a) The system is to be Asphalt Shingles per Specification Section 07 31 13.
b) Where indicated on the Form of Proposal as “Metal Roofing Manufacturer,” Contractor shall change wording to “Asphalt Shingle Manufacturer” during submission process. New form will not be issued.
11) Can you clarify the required roofing warranties, specifically the 20-year workmanship requirement and the separate two-year installer warranty?
a) Refer to Specification Section 07 31 13 Asphalt Shingles Section 1.1 Warranty for breakout of warranty requirements. All requirements shall be met by bidding contractor.
b) 20 year workmanship requirement pertains to the nonprorated manufacturer’s warranty with labor. 2 year installer warranty pertains to the installing contractor specifically.
12) Is the Tremco ExoAir 230 fluid-applied air barrier required behind all new fiber-cement siding?
a) Yes. This product is serving as a continuous weather barrier.
13) Please clarify the required siding clearance at grade and adjacent paving, as the elevations and wall details reference different elevations.
a) The elevations have dimensions showing elevation changes in panels from grade because the grades around the building slope. The fiber cement siding must be 6” minimum from grade. Refer to wall section A/A401 for condition at pavement and further information. The dimensions on the elevations on A301 were coordinated with the Site Grading Plan – Restroom on C101 and the width of each fiber cement panel. Wall Section A/A401 notes that the bottom of the panel height from grade varies with grade changes. At paving, the 4” minimum note applies along with the other notes called out on A/A401.
14) Are there any additional exterior flashing, sealant, or weatherproofing requirements not specifically identified in the architectural details?
a) All installed work must meet the requirements set forth in the Contract Documents and manufacturer’s requirements.
DRAWINGS
15) E101: Additional lights added to Lighting Fixture Schedule.
END of ADDENDUM
S
S a
"WP"
a,b,c,...
JUNCTION BOX AS REQUIRED OR AS NOTED.
PHASE
CONDUCTOR
NEUTRAL
GROUND
LC1-1
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
SYMBOL DESCRIPTIONDESCRIPTIONSYMBOL
WALL OUTLET WITH 20A, 125V DUPLEX RECEPTACLE. INSTALL
18 INCHES ABOVE FINISHED FLOOR TO CENTER, UNLESS
NOTED OTHERWISE.
WALL OUTLET WITH 20A, 125V DUPLEX RECEPTACLE. INSTALL
ABOVE COUNTER TOP, UNLESS NOTED OTHERWISE. COORDINATE
THE REQUIRED HEIGHT ABOVE COUNTER TOP WITH ARCHITECT
AND ALL OTHER INSTALLATION IN AREA PRIOR TO ROUGH-IN.
NUMBER INDICATES MOUNTING HEIGHT ABOVE FINISHED
FLOOR TO BOTTOM OF OUTLET BOX WHEN SHOWN NEXT
TO SYMBOL.
+42"
SYMBOL INDICATES FIXTURE TYPE WHEN SHOWN ON LIGHTING
PLANS AND SITE ELECTRICAL PLANS ADJACENT TO FIXTURE
SYMBOL. REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE
REQUIREMENTS.
"GFI"
OUTLET BOX AND 20A, SINGLE POLE SWITCH. MOUNT AT 46 INCHES
ABOVE FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.
LOCATE WITHIN 8" OF STRIKE SIDE OF DOOR, UNLESS NOTED
OTHERWISE. LOWER CASE LETTER INDICATES CIRCUIT SWITCHED.
NOMENCLATURE INDICATES GROUND FAULT
INTERRUPTER TYPE RECEPTACLE WHEN SHOWN PLANS
ADJACENT TO SYMBOL.
OUTLET AND EXIT LIGHT FIXTURE AS SCHEDULED OR NOTED.
ARROWS INDICATE DIRECTION ARROWS REQUIRED.
OCCUPANCY SENSOR. THE LETTER(S) DESIGNATION NEXT TO
THE SYMBOL (IF SHOWN) INDICATE SWITCHING ZONES TO BE
CONTROLLED VIA THE OCCUPANCY SENSOR. IF A LETTER
DESIGNATION IS NOT SHOWN, THE OCCUPANCY SENSOR SHALL
CONTROL ALL LIGHTING FIXTURES WITHIN THE ROOM. SEE
OCCUPANCY SENSOR CONTROL WIRING DIAGRAMS, AND
DETAILS, SHEET E101, FOR ADDITIONAL REQUIREMENTS.
LOWER CASE LETTERS INDICATE SWITCHING ARRANGEMENT
WHEN SHOWN NEXT TO OR WITHIN SYMBOL ON PLANS.
OCCUPANCY SENSOR SWITCH. MOUNT AT 46 INCHES ABOVE
FINISHED FLOOR TO CENTER, UNLESS NOTED OTHERWISE.
LOCATE WITHIN 8" OF STRIKE SIDE OF DOOR, UNLESS NOTED
OTHERWISE.
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
a
O
ELECTRICAL LEGEND - POWERELECTRICAL LEGEND - LIGHTING
J J
WALL OUTLET (WHERE REQUIRED) AND LIGHTING FIXTURE AS
SCHEDULED.
NOMENCLATURE INDICATES WEATHER RESISTANT
RECEPTACLE IN WEATHERPROOF WHILE IN-USE DIECAST
ALUMINUM ENCLOSURE WHEN SHOWN ON PLANS ADJACENT
TO SYMBOL.
HOMERUN TO PANEL INDICATED. PREFIX INDICATES PANEL
NOMENCLATURE. NUMBERS INDICATE CIRCUIT NUMBERS.
CIRCUIT. NUMBER OF CROSSBARS INDICATE QUANTITY OF
CONDUCTORS REQUIRED. MINIMUM CONDUIT SIZE SHALL BE
3/4 INCH TRADE SIZE. MINIMUM SIZE CONDUCTORS SHALL BE
12 AWG.
"WR" NOMENCLATURE INDICATES WEATHER RESISTANT
RECEPTACLE WHEN SHOWN ON PLANS ADJACENT TO SYMBOL.
"EX" NOMENCLATURE INDICATES EXISTING DEVICE WHEN
SHOWN ON PLANS ADJACENT TO SYMBOL.
L11-17
UNLESS NOTED OTHERWISE, NOMENCLATURE SHOWN NEXT
TO DEVICE SYMBOL INDICATES THE PANEL AND BRANCH
CIRCUIT WHICH SHALL BE USED TO FEED THE DEVICE.
PANEL ID
CKT. NO.
"TR" NOMENCLATURE INDICATES TAMPER RESISTANT RECEPTACLE
WHEN SHOWN ON PLANS ADJACENT TO SYMBOL.
WALL OUTLET WITH TYPE OF RECEPTACLE AS NOTED.
MOUNT 18 INCHES ABOVE FINISHED FLOOR TO CENTER,
UNLESS NOTED OTHERWISE.
GENERAL DEMOLITION NOTES:
GD1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE
SITE TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. THESE
REMOVAL DRAWINGS SHALL SERVE TO AID THE CONTRACTOR IN HIS
EVALUATION OF THE EXTENT OF REMOVALS, BUT SHALL NOT BE HELD
TO BE ALL INCLUSIVE.
GD2. FOR FURTHER REQUIREMENTS WITH REGARD TO EXTENT OF
REMOVALS, SEE THE NEW CONSTRUCTION PLANS WHICH ILLUSTRATE
THE ADJACENT NEW CONSTRUCTION.
GD3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVALS
REQUIRED FOR THE INSTALLATION OF NEW WORK, WHETHER OR NOT
IT IS SPECIFICALLY INDICATED OR NOTED IN THESE DOCUMENTS.
GD4. ALL CONDUIT RUNS TO REMOVED EQUIPMENT SHALL HAVE ALL
CONDUCTORS REMOVED, UNLESS CONDUCTORS ARE REQUIRED TO
SERVE EXISTING EQUIPMENT TO REMAIN.
GD5. REMOVAL OF EMPTY CONDUIT SHALL BE REQUIRED ONLY IF
SUCH CONDUIT INTERFERES WITH THE NEW CONSTRUCTION AND/OR IF
INDICATED TO BE DISCONNECT AND REMOVED COMPLETE BACK TO
SOURCE OF FEED.
GD6. IF PORTIONS OF CIRCUITS SERVING EQUIPMENT TO REMAIN
MUST BE RELOCATED OR REMOVED DUE TO OTHER DEMOLITION OR
DUE TO INTERFERENCE WITH NEW EQUIPMENT INSTALLATION, THE
CIRCUITS SHALL BE MODIFIED IN A MANNER WHICH SHALL ENSURE
PROPER OPERATION OF THE EQUIPMENT AFTER THE CONSTRUCTION
IS COMPLETE. CONTRACTOR SHALL USE THE SAME GAUGE AND TYPE
OF CONDUCTOR, AND THE SAME CONDUIT SIZE AS EXISTING TO MAKE
ALL REQUIRED CIRCUIT MODIFICATIONS.
GD7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER
DISPOSAL OF ALL EQUIPMENT REMOVED.
GD8. OWNER RESERVES THE FIRST RIGHT OF REFUSAL OF REMOVED
EQUIPMENT.
GD9. THE CONTRACTOR SHALL COORDINATE DISRUPTION OF
SERVICES WITH THE OWNER. DISRUPTIONS OF SERVICES SHALL BE
KEPT TO A MINIMUM. DISRUPTIONS SHALL ONLY OCCUR AFTER
RECEIVING OWNER PRIOR APPROVAL.
GD10. THE CONTRACTOR SHALL REFER TO THE MECHANICAL,
PLUMBING, AND ARCHITECTURAL PLANS FOR ADDITIONAL
REQUIREMENTS ON EQUIPMENT AND AREAS REQUIRING
DISCONNECTIONS AND REMOVALS.
GD11. IT IS NOT THE INTENT OF THIS DRAWING TO SHOW ALL EXISTING
ELECTRICAL DEVICES, EQUIPMENT, AND ITEMS TO BE DISCONNECTED
AND REMOVED. THIS DRAWING DOES NOT SHOW ALL ELECTRICAL
DEVICES, EQUIPMENT, AND ITEMS TO BE DISCONNECTED AND
REMOVED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING
THE PROJECT AREAS TO BECOME FAMILIAR WITH THE EXISTING
CONDITIONS AND TO DETERMINE THE AMOUNT OF REMOVALS.
LIGHTING FIXTURE SCHEDULE
MANUFACTURERDESCRIPTION
TYPE
FIXTURE SERIES
LAMP
LITHONIA
LEDS 4000K
(90,000 HRS WITH
81% LUMEN
MAINTENANCE)
80 CRI
CSVT-L48-AL03-MVOLT- SWW3 80CRI
SERIES
LITHONIA
LED RED
LHQM QUANTUM SERIES
WATTS
MOUNTING
FIXTURE
VOLTAGE
120/277
(MULTI-
VOLT)
44W
(NOMINAL
FIXTURE
INPUT
WATTS)
SUSPENDED
/ CHAIN
120/277
(MULTI-
VOLT)
AS
REQ'D
CEILING
REMARKSSYMBOL
F1H
4' VAPER TIGHT LED STRIP FIXTURE WITH
STAINLESS STEEL LATCHES & 301 STAINLESS
MOUNTING HARDWARE. SWITCHED TO HIGH
LUMEN OUTPUT.
[FIXTURE LUMEN OUTPUT ~ 5000 LUMENS]
EX1R
EXIT LIGHTING FIXTURE, SINGLE-FACED, WHITE
HOUSING, RED LETTERS. PROVIDE WITH BATTERY
BACK UP SYSTEM TO ILLUMINATE SIGN ON LOSS OF
NORMAL POWER SOURCE FOR A MINIMUM OF 90
MINUTES WITH SELF-DIAGNOSTICS FUNCTIONALITY.
PROVIDE WITH INTEGRAL LIGHT HEADS FOR
EGRESS ILLUMINATION.
ISOLITE
DUAL-LITE LED
BUG-6W-WH-SD SERIES
EV4D-02WAL SERIES
120/277
(MULTI-
VOLT)
6W
(NOMINAL
FIXTURE
INPUT
WATTS)
WALLEMB1
LED THERMOPLASTIC EMERGENCY LIGHTING UNIT
WITH TWO LED FIXTURE HEADS, INTEGRAL
BATTERY BACK-UP WITH HIGH OUTPUT LITHIUM
IRON PHOSPHATE BATTERIES CAPABLE OF 90
MINUTES OF OPERATION ON LOSS OF NORMAL
POWER SOURCE. PROVIDE WITH SELF-
DIAGNOSTICS.
(END OF LIGHTING FIXTURE SCHEDULE)
LITHONIA ELM4L SERIES
CONTRACTOR SHALL DETERMINE BEST INSTALLATION HARDWARE
SELECTION BASED ON INSTALLATION MATERIALS AND SURFACES.
CONTRACTOR SHALL DETERMINE IF WET LOCATION FITTINGS OUT BOTH
ENDS OPTION IS REQUIRED FOR INSTALLATION.
BEACON
LEDS 5000K
(50,000 HRS WITH
70% LUMEN
MAINTENANCE)
90+ CRI
RWL1-48L-15-5K7-4W-UNV
120/277
(MULTI-
VOLT)
15W
(NOMINAL
FIXTURE
INPUT
WATTS)
WALLF3
LOW PROFILE LED WALL LUMINAIRE SCONCE WITH
DIE-CAST HOUSING.
FIXTURE LUMEN OUTPUT ~ 2000 LUMENS]
DUAL-LITE EVCURWD4 SERIES
COMPASS CCRG SERIES
COOPER APVT SERIES
KURTZON WL-SEG SERIES
EX1L
PROVIDE CHEVRONS AS INDICATED.
ELITE LIGHTING
LEDS 4000K
(50,000 HRS WITH
70% LUMEN
MAINTENANCE)
90+ CRI
RL675-1100L-DIMTR-120-27K/30K/35K/40K/
50K-90-WH/RL-ACC-SLIM-6-ROUGHPLATE
SERIES
120/277
(MULTI-
VOLT)
14W
(NOMINAL
FIXTURE
INPUT
WATTS)
RECESSEDF2
6” ROUND MULTI-CCT & OUTPUT LED SLIM DISK
WITH DIE CAST ALUMINUM BODY & TRIM, ROUND
FLAT LENS WITH WHITE TRIM. PROVIDE WITH
ROUGH-IN PLATE AS REQUIRED FOR
INSTALLATION.
FIXTURE LUMEN OUTPUT ~ 1000 LUMENS]
CONTRACTOR SHALL DETERMINE BEST INSTALLATION HARDWARE
SELECTION BASED ON INSTALLATION MATERIALS AND SURFACES.
CONTRACTOR SHALL FIELD SET / SELECT COLOR TEMPERATURE AND
FIXTURE OUTPUT IN FIELD PER MFG INSTALLATION INSTRUCTIONS.
SUBSTITUTIONS BY ARCHITECT AND ENGINEER APPROVAL ONLY.
SUBSTITUTIONS BY ARCHITECT AND ENGINEER APPROVAL ONLY.
HALO HLB6LSFS5 SERIES
NLS
TRC-LWM-1-T4FTW-16L-35-50K8-UNV-WSM-
D-STANDARD FINISH-CTG SERIES
SURE-LITE LPXC25R3SD
SURE-LITE SELHP100R3SD
BEGHELLI USA BS100LED-4-HT-LO-WT40-120-277V
LIGHTOLIER
FD2-6R-SLM-Z10-SCT-U-W-
DSANCPR468 SERIES
ILP SWS-2L-U-50-T4 SERIES
BEGHELLI USA EPC-ATR
BEGHELLI USA BBXSEWHTAT
R e d
W h t
Wht
Blk/Orn Blue
Blue
Relay (if req'd)
Normally Closed
Photocell (if req'd)
Common
Normally Open
Auto Dimming Ctrl (if req'd)
7-Brn
8-Vio
6-Gry
5-Blu
4-Vio w/ Wht stripe
3-Blk
2-Wht
1-Red
SWITCH "a" N
SWITCH "b"
Power Pack
Additional Occupancy
Sensor (qty. as shown on Lighting Plans)
3-WAY
SWITCH
3-WAY
SWITCH
4-WAY
SWITCH
UNSWITCHED HOT CONDUCTOR.
SWITCHED HOT CONDUCTOR.
Occupancy
Sensor
LIGHTING CONTROL DIAGRAM - TYPICAL FOR ROOMS WITH SINGLE OR
MULTIPLE CONTROL SWITCHES & OCCUPANCY SENSORS
NO SCALE
7-Brn
8-Vio
6-Gry
5-Blu
4-Vio w/ Wht stripe
3-Blk
2-Wht
1-Red
B lk
Relay (if req'd)
Relay (if req'd)
Relay (if req'd)
Normally Closed
Photocell (if req'd)
Common
Normally Open
Auto Dimming Ctrl (if req'd)
Relay (if req'd)
Relay (if req'd)
GENERAL LIGHTING CONTROL NOTES:
A. OCCUPANCY SENSOR DESIGNS ARE BASED ON PRODUCTS BY ACUITY LIGHTING CONTROLS. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
DESIGN CHANGES REQUIRED TO USE PRODUCTS BY ANOTHER MANUFACTURER.
B. CEILING MOUNT SENSOR LOCATIONS ARE BASED ON SENSOR SWITCH CM PDT9 SERIES OCCUPANCY SENSOR.
C. IT IS NOT THE INTENT OF THIS DRAWING TO SHOW, NOR DOES THIS DRAWING SHOW EVERY CONFIGURATION OF LIGHTING CONTROL DIAGRAM REQUIRED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING ALL LIGHTING CONTROL PER THE LIGHTING CONTROL SYSTEM
MANUFACTURER'S REQUIREMENTS.
OPERATION & PROGRAMMING NOTE: OCCUPANCY SENSORS SHALL ALLOW LIGHTING FIXTURES TO BE "TURNED ON" VIA THE LIGHTING CONTROL SWITCHES WHEN OCCUPANCY HAS BEEN DETECTED. THE LIGHTING FIXTURES SHALL REMAIN "ON" UNTIL AREA HAS BEEN FOUND TO BE "UNOCCUPIED" FOR THE PROGRAMMED TIME PERIOD (OR WHENEVER THE LIGHTING CONTROL SWITCH HAS BEEN TURNED "OFF". COORDINATE "ON" DURATION TIME PERIODS FOR EACH TYPE OF ROOM WITH OWNER PRIOR TO INSTALLATION OF THE
OCCUPANCY SENSORS.
NOTE: CONTROL DIAGRAM IS TYPICAL FOR ALL SPACES WITH ONE OR MORE
SWITCHES AND ONE OR MORE OCCUPANCY SENSORS, UNLESS NOTED OTHERWISE.
NOTE: SWITCH CONFIGURATIONS SHOWN FOR WIRING
REFERENCE ONLY. SWITCH CONFIGURATION FOR A
PARTICULAR SPACE SHALL BE A COMBINATION OF THE
ABOVE TYPES OF SWITCHES, QUANTITY AS INDICATED
ON THE LIGHTING PLANS.
R E
NI
G
NEAN L
OI
S
E
S
F O R P
E
KENTU
C
K Y
FO
ET
A T S
D
ESNE
L I C
CRAIG
34886
AJ
SON
A&E FILE NO.
DRAWING DATE
DRAWN BY
CHECKED BY
DECA LOG #
DRAWING INFORMATION
DRAWING NO.
AS BUILT DATE
DATEDESCRIPTION OF REVISIONS
REVISION HISTORY OF THIS DRAWING
DATEDESCRIPTION OF REVISIONS
FRANKFORT, KENTUCKY
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
FINANCE AND ADMINISTRATION CABINET
COMMONWEALTH OF KENTUCKY
ACCOUNT NO.
670-CBRB-PF28-00
PHASE
RTA DATE
RTA
09/08/2026
09/08/2026
/1 /2
:3
:0
A M
E101BJH
09/08/2026
2505-196
JMC
ELECTRICAL LEGEND
-1
P E
N N
Y R
IL
E
F O
R E
S T
B E
A C
H R
E S
T R
O O
M B
U
IL
D
IN
G
PENNYRILE FOREST BEACH RESTROOM BUILDING
ADD-001 11/17/26
| Item 1: Refer to attached addendum for all additions, deletions, and/or changes to specifications and/or drawings. |
| END OF ADDENDUM |
File details come from the government source that posted it. Updated .