Addendum 1.pdf
PDF 14 MB Posted
- Solicitation number
- M-2510C
- Issued by
- Garfield County, Oklahoma
About this file
Addendum No. 1 is issued by the City of Enid, Oklahoma for the Meadowlake Golf Course Automatic Irrigation Improvements project (Project M-2510C). The addendum modifies the original contract documents and provides clarifications for the irrigation system upgrade. The project involves comprehensive automatic irrigation improvements for the golf course, with specific details on pipe sizing, valve types, and installation requirements. The bid date is set for 10/31/2024, and bidders are required to acknowledge receipt of this addendum, with failure to do so potentially resulting in bid disqualification.
The addendum includes technical specifications for irrigation components, such as specifying 3" lateral valves and lateral loop feeders, and 2" lateral loops. The project will utilize Toro and Hunter irrigation equipment, including rotors, sprinklers, controllers, and valves. The irrigation system will employ HDPE (High-Density Polyethylene) piping with specific DR (Dimension Ratio) ratings, and includes provisions for power wiring, control valve wiring, and grounding requirements. The existing Watertronics pump station will be retained, and the system will incorporate a Toro Lynx central control software with a premium computer and maintenance radios.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| M-2510C Bid Package.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Main Office 400 - 5th Street
West Des Moines, IA 50265 Phone: (515) 225-6365
Fax: (515) 225-6366
A N I R R I G A T I O N C O N S U L T I N G & W A T E R M A N A G E M E N T F I R M
Irrigation Addendum #1
To: All Bidders Date: 10/21/2024
From: EC Design Group
Project: Meadowlake Golf Course
Bid Date: 10/31/2024
This addendum shall be a part of the Plans, Contract Documents and Specifications to the same extent as though it were originally included therein, and it shall supersede anything contained in the Plans, Contract Documents and Specifications with which it might conflict. Acknowledgement of receipt of this Addendum must be provided on the proposal form in the Contract Documents.
Clarifications:
1.Refer to Typical Golf Hole for lateral pipe sizing. All lateral valves and lateral loop feeders to be 3” and lateral loops to be 2” pipe sizes.
2. All lateral vales to be 3” Aquafuse 360 PE Valve – See plans.
Amendments to Plans:
1. Revised plans and irrigation legend.
2. Added Remote Control Valve Detail.
Attachments:
Meadowlake GC_ Addendum #1
END OF ADDENDUM
Please notify the office of EC Design Group, Ltd. in writing if you feel the information above is not clear or misrepresented within 24 hours of receiving this addendum and/or before bid due date.
LI-4
LI-3 ELECTRICAL SCHEMATIC PLAN
IMPACT COVERAGE PLAN
DESCRIPTION
COVER
HYDRAULIC PIPING PLANLI-2
LI-1
LI-0
SHEET
MEADOWLAKE GOLF COURSE
LI-5 IRRIGATION DETAILS
SITE IRRIGATION PLAN
NOTE:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW OF THE ABOVE AND ANY OTHER PLANS THAT PERTAIN TO THE
COORDINATION OF THE IRRIGATION CONSTRUCTION, WHETHER THEY BE NOTED OR NOT.
2. IRRIGATION PLANS AND SPECIFICATIONS ARE DIAGRAMMATIC IN NATURE AND ARE NOT A LIST OF INSTRUCTIONS FOR CONSTRUCTION, BUT RATHER TO ILLUSTRATE A DESIGN INTENT. THEREFORE ANY AND ALL CHANGES, CONFLICTS, DISCREPANCIES, OMISSIONS, AND QUESTIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE SAID IRRIGATION CONSULTANT DURING THE BIDDING
AND CONSTRUCTION PERIOD IN WRITING.
E R
IK
C
H R
IS
T
IA
N
SE
N
D E
SI
G
N G
R O
U P, L T
D
5T H
ST
RE
ET
W
ES
T
DE
S M
OI
NE
S, IO
W A
5-
PH
ON
E
(5
) 2
-6
FA
X (5
) 2
-6
REVISIONS:
SHEET #:
D R
AW
IN
G T
IT
LE
SC
AL
E:
DATE:
DRAWN BY:
REVIEWED BY:
09/20/2024
PR
IN
TE
D
M
EA
D O
W
LA
K E
G O
LF
C
O U
R
SE
EN
ID
, O K
LI-0
C O
VE
R
N O
N E
PC
EC
10.24.24
Z:
\C ol e' s Pr oj ec ts \M ea do w la ke \M ea do w la ke G
C .d w g
/2
1/
0:
:2
AM
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Hunter I-20-04-SS Turf Rotor, 4.0" Pop-Up. Adjustable and Full Circle. Stainless Steel Riser. Drain Check Valve. Standard Nozzle.
Toro FLX34-348-2 Full-circle golf sprinkler, body inlet 1", ACME body threads, electric valve type w/ Spike Guard solenoid, pressure regulation at 80psi
Toro FLX35-358-2 Adjustable from 40 to 330 degrees, and 360 full circle. 1" inlet, ACME body threads, electric valve type w/ Spike Guard solenoid, pressure regulation at 80psi
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Toro P220G-27-04 Electric, 1" Plastic In-Line Remote Control Valve With EZ Reg Pressure Regulator.
Toro 474-00 One-Piece, 1" Single Lug Quick Coupler Valve with Standard Cover.
Clow Isolation Valve w/ HDPE Extensions
- Line Sized
Bermad C30 2" Air/Vacuum Relief Valve
(10) To Be Field Located By Irrigation Consultant
Aquafuse 360 PE Ball Valve - 2" 360 Degree PE valve with Position Indication and HDPE 4710 DR13.5 Extensions. Provide with Manufacturers 10" Round Valve Box
Drain/Fill Valve - Aquafuse 360 PE Ball Valve 2" 360 Degree PE valve with Position Indication and HDPE 4710 DR13.5 Extensions. Provide with Manufacturers 10" Round Valve Box
Toro G4-XXP6R4 Toro G4 OSMAC Satellite Controller w/ Plastic Green Cabinet, Radio Controls, Large Terminal Blocks, Switches & Premium Surge - See Plan For Station Counts.
Spectrum Watchdog Wireless/Solar Weather Station - Actual Location By Owner
Toro LX-04-5-21 Toro Lynx central control software w/ premium computer, (5) years NSN support, (4) maintenance radios and all associated equipment.
Existing Watertronics Pump Station 1
Irrigation Lateral Line: HDPE PE4710 DR 13.5 52,698 l.f.
Irrigation Mainline: HDPE PE4710 DR 13.5 20,594 l.f.
220vac Power Wire (Twisted Single Conductor - Red, Black, White, Green & #8 Bare Shielding Wire) - As Per Local Codes
Irrigation Zone Limits
Note: All Quantities Are For Reference Only. Contractor Responsible For Actual Counts.
A
D
X
XX
W
CC
P
LEGEND
DESIGN NOTES:
ELECTRICAL NOTES:
PLUMBING NOTES:
PROGRAMMING NOTES:
1. ALL 120 V.A.C. POWER SPLICES AT FIELD SATELLITES.
2. ALL POWER WIRE TAPS AND CONNECTIONS SHALL CONFORM TO ALL LOCAL AND STATE CODES
AND PERFORMED BY LICENSED ELECTRICIAN.
3. 24" LOOP OF WIRE LOCATED BELOW EACH HEAD.
4. ALL 24 V.A.C. SECONDARY WIRING SHALL BE (RED) #14 HOT AND (WHITE) #12 COMMON. (ONE HOT
WIRE PER HEAD)
5. ALL WIRE SHALL HAVE ENOUGH SLACK AS TO ACCOMMODATE FOR EXPANSION AND/OR
CONTRACTION.
6. ALL WIRE TO BE UL APPROVED FOR DIRECT BURIAL.
7. ALL 120 V.A.C. PRIMARY, AND 24 V.A.C. SECONDARY POWER TO BE INSTALLED AS PER STATE AND LOCAL CODES. SIZED AS PER PLAN WITH GROUND WIRE; MEETING N.E.C. REQUIREMENTS.
8. TWO SPARE HOT (#14) WIRE TO EACH GREEN AND ONE SPARE HOT (#14) TO WIRE TO EACH TEE
COMPLEX AND MARKED AS SPACE (BLUE IN COLOR).
1. FIELD SATELLITES SHALL CARRY APPROPRIATE STATION CARDS FOR INDIVIDUAL HEAD
CONTROL OF ALL SPRINKLERS.
2. ALL SPRINKLERS SHALL HAVE ONE WIRE (HOT 24 V.A.C.) TO RESPECTIVE FIELD SATELLITE.
3. ALL SATELLITE LOCATIONS SHALL BE IN ACCORDANCE WITH RAIN FALL SURVEYS AND OUT OF
100 YEAR FLOOD PLAIN.
SATELLITE NUMBER
APPROXIMATE STATION COUNT
XX
X
1. ALL PRODUCT APPLICATIONS AND INSTALLATIONS MUST MEET MANUFACTURER'S
REQUIREMENTS.
2. FLOW RATES THROUGH HDPE PIPING NOT TO EXCEED MANUFACTURER'S RECOMMENDATIONS.
3. PIPING AS SHOWN IS DIAGRAMMATIC IN NATURE. ALL PIPING TO BE LOCATED WITHIN OWNER'S
PROPERTY LINES.
4. CONTRACTOR IS RESPONSIBLE FOR PROPER OPERATION OF IRRIGATION SYSTEM. SYSTEM
SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATIONS AND SHALL WATER ALL SEEDED
AND SODDED AREAS NOTED. IRRIGATION PLAN IS INTENDED TO INCLUDE EVERYTHING
NECESSARY TO THE PROPER OPERATION OF SAID IRRIGATION SYSTEM. IF ADJUSTMENTS ARE
REQUIRED, CONTRACTOR SHALL MAKE ADJUSTMENTS FOR SAME.
5. IRRIGATION PLANS SHALL HAVE PRECEDENCE OVER IRRIGATION SPECIFICATIONS. ANY
DISCREPANCIES BETWEEN THESE TWO DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF
THE IRRIGATION CONSULTANT BEFORE INSTALLATION.
6. IT IS THE INTENT TO KEEP IRRIGATION WATER OFF OF ALL BUILDINGS, SIDEWALKS AND PARKING AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FIELD TUNE EACH
SPRINKLER AS TO KEEPING IRRIGATION ADJUSTED TO GRASSED AND SEEDED AREAS ONLY. IT
WILL ALSO BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO SUPPLY THE OWNER
WITH AN OPERATING SCHEDULE THAT WORKS WITH EXISTING PLANS AND ANY FIELD
ADJUSTMENTS.
7. IT IS THE INTENT OF THE IRRIGATION DESIGN TO ACHIEVE HEAD TO HEAD COVERAGE IN ALL
GRASSED AND SEEDED AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION
CONTRACTOR TO ADJUST FOR SAME.
8. IRRIGATION PLANS ARE DIAGRAMMATIC IN NATURE CONTRACTOR WILL BE RESPONSIBLE FOR THE LOCATION OF ALL EQUIPMENT AS STAKED BY IRRIGATION CONSULTANT. SAID EQUIPMENT, WHEN FIELD LOCATED, MAY VARY FROM PROPOSED PLAN DUE TO SITE CONDITIONS AND
CONTRACTOR WILL MAKE ADJUSTMENTS ACCORDINGLY AT NO ADDITIONAL COST TO OWNER.
1. ALL PIPE FITTINGS SHALL BE OF FUSED HDPE E.F. OR F.M. RATED TYPE. ALL SPRINKLERS SHALL
BE MOUNTED WITH MANUFACTURER'S SWING JOINTS ON CMF GLOBAL FUSED HDPE SERVICE
RISERS. NO BRAND MIXING ALLOWED AND CONTRACTOR/EQUIPMENT TO BE SITE CERTIFIED BY
SUPPLIER AS SPECIFIED - NO EXCEPTIONS.
2. ALL PIPE SHALL BE CARRIED IN SEPARATE TRENCH.
NG
PG
SCALE: NOT TO SCALE
TYPICAL HOLE
70'
70'
65'
65' x
70'
70'360 PE BALL VALVE WITH HDPE
EXTENSIONS
3"1" Q.C.V.
TEE SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE
AS PER STAKING
HDPE 4710 DR13.5 (UNLESS NOTED)
LATERAL PIPING
FAIRWAY SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
1" Q.C.V.
GREENS SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
SURROUND SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
ALL PIPE HDPE 4710 DR13.5 (UNLESS
NOTED)
360 PE BALL VALVE WITH HDPE
EXTENSIONS
3"
R.F. SATELLITE
220 V.A.C. POWER WIRE - SEE PLANS AND
GROUNDING DETAIL
HDPE 4710 DR13.5 MAIN LINE PIPING
3"
360 PE BALL VALVE WITH HDPE
EXTENSIONS
2"
2"
2"
2"
3"
THIS IMPACT STUDY SHOWS APPROXIMATE COVERAGE OF SPRINKLER HEADS. ACTUAL COVERAGE
WILL VARY DEPENDING ON MANY FACTORS SUCH AS, BUT NOT LIMITED TO: TOTAL OPERATION OF SYSTEM, RETURNING SPRINKLER COVERAGE, WIND CONDITIONS, PRECIPITATION RATE FACTORS, AND LENGTH OF OPERATION. THIS STUDY IS TO BE USED FOR INFORMATIONAL PURPOSES ONLY AND
COULD BE EFFECTED BY ONE OR ALL OF THE ABOVE ISSUES.
IMPACT COVERAGE NOTES:
IMPACT COVERAGE PLAN
SCALE: 1" = 100'-0"NORTH
E R
IK
C
H R
IS
T
IA
N
SE
N
D E
SI
G
N G
R O
U P, L T
D
5T H
ST
T
DE
S M
OI
NE
S, IO
W A
5-
PH
ON
E
(5
) 2
-6
FA
X (5
) 2
-6
REVISIONS:
SHEET #:
D R
AW
IN
G T
IT
LE
SC
AL
E:
DATE:
DRAWN BY:
REVIEWED BY:
09/20/2024
PR
IN
TE
D
M
EA
D O
W
LA
K E
G O
LF
C
O U
R
SE
EN
ID
, O K
LI-1
IM
PA
C T
C O
VE
R
A G
E
PL
A N
1"
'-0
PC
EC
10.24.24
Z:
\C ol e' s Pr oj ec ts \M ea do w la ke \M ea do w la ke G
C .d w g
/2
1/
0:
:2
AM
AutoCAD SHX Text xx
Turf Rotor, 4.0" Pop-Up. Adjustable and Full Circle. Stainless Steel Riser. Drain Check Valve. Standard Nozzle.
Toro FLX34-348-2 Full-circle golf sprinkler, body inlet 1", ACME body threads, electric valve type w/ Spike Guard solenoid, pressure regulation at 80psi
Toro FLX35-358-2 Adjustable from 40 to 330 degrees, and 360 full circle. 1" inlet, ACME body threads, electric valve type w/ Spike Guard solenoid, pressure regulation at 80psi
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Toro P220G-27-04 Electric, 1" Plastic In-Line Remote Control Valve With EZ Reg Pressure Regulator.
Toro 474-00 One-Piece, 1" Single Lug Quick Coupler Valve with Standard Cover.
Clow Isolation Valve w/ HDPE Extensions
- Line Sized
Bermad C30 2" Air/Vacuum Relief Valve
(10) To Be Field Located By Irrigation Consultant
Aquafuse 360 PE Ball Valve - 2" 360 Degree PE valve with Position Indication and HDPE 4710 DR13.5 Extensions. Provide with Manufacturers 10" Round Valve Box
Drain/Fill Valve - Aquafuse 360 PE Ball Valve 2" 360 Degree PE valve with Position Indication and HDPE 4710 DR13.5 Extensions. Provide with Manufacturers 10" Round Valve Box
Toro G4-XXP6R4 Toro G4 OSMAC Satellite Controller w/ Plastic Green Cabinet, Radio Controls, Large Terminal Blocks, Switches & Premium Surge - See Plan For Station Counts.
Spectrum Watchdog Wireless/Solar Weather Station - Actual Location By Owner
Toro LX-04-5-21 Toro Lynx central control software w/ premium computer, (5) years NSN support, (4) maintenance radios and all associated equipment.
Existing Watertronics Pump Station 1
Irrigation Lateral Line: HDPE PE4710 DR 13.5 52,698 l.f.
Irrigation Mainline: HDPE PE4710 DR 13.5 20,594 l.f.
220vac Power Wire (Twisted Single Conductor - Red, Black, White, Green & #8 Bare Shielding Wire) - As Per Local Codes
Irrigation Zone Limits
Note: All Quantities Are For Reference Only. Contractor Responsible For Actual Counts.
A
D
X
XX
W
CC
P
LEGEND
DESIGN NOTES:
ELECTRICAL NOTES:
PLUMBING NOTES:
PROGRAMMING NOTES:
1. ALL 120 V.A.C. POWER SPLICES AT FIELD SATELLITES.
2. ALL POWER WIRE TAPS AND CONNECTIONS SHALL CONFORM TO ALL LOCAL AND STATE CODES
AND PERFORMED BY LICENSED ELECTRICIAN.
3. 24" LOOP OF WIRE LOCATED BELOW EACH HEAD.
4. ALL 24 V.A.C. SECONDARY WIRING SHALL BE (RED) #14 HOT AND (WHITE) #12 COMMON. (ONE HOT
WIRE PER HEAD)
5. ALL WIRE SHALL HAVE ENOUGH SLACK AS TO ACCOMMODATE FOR EXPANSION AND/OR
CONTRACTION.
6. ALL WIRE TO BE UL APPROVED FOR DIRECT BURIAL.
7. ALL 120 V.A.C. PRIMARY, AND 24 V.A.C. SECONDARY POWER TO BE INSTALLED AS PER STATE AND LOCAL CODES. SIZED AS PER PLAN WITH GROUND WIRE; MEETING N.E.C. REQUIREMENTS.
8. TWO SPARE HOT (#14) WIRE TO EACH GREEN AND ONE SPARE HOT (#14) TO WIRE TO EACH TEE
COMPLEX AND MARKED AS SPACE (BLUE IN COLOR).
1. FIELD SATELLITES SHALL CARRY APPROPRIATE STATION CARDS FOR INDIVIDUAL HEAD
CONTROL OF ALL SPRINKLERS.
2. ALL SPRINKLERS SHALL HAVE ONE WIRE (HOT 24 V.A.C.) TO RESPECTIVE FIELD SATELLITE.
3. ALL SATELLITE LOCATIONS SHALL BE IN ACCORDANCE WITH RAIN FALL SURVEYS AND OUT OF
100 YEAR FLOOD PLAIN.
SATELLITE NUMBER
APPROXIMATE STATION COUNT
XX
X
1. ALL PRODUCT APPLICATIONS AND INSTALLATIONS MUST MEET MANUFACTURER'S
REQUIREMENTS.
2. FLOW RATES THROUGH HDPE PIPING NOT TO EXCEED MANUFACTURER'S RECOMMENDATIONS.
3. PIPING AS SHOWN IS DIAGRAMMATIC IN NATURE. ALL PIPING TO BE LOCATED WITHIN OWNER'S
PROPERTY LINES.
4. CONTRACTOR IS RESPONSIBLE FOR PROPER OPERATION OF IRRIGATION SYSTEM. SYSTEM
SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATIONS AND SHALL WATER ALL SEEDED
AND SODDED AREAS NOTED. IRRIGATION PLAN IS INTENDED TO INCLUDE EVERYTHING
NECESSARY TO THE PROPER OPERATION OF SAID IRRIGATION SYSTEM. IF ADJUSTMENTS ARE
REQUIRED, CONTRACTOR SHALL MAKE ADJUSTMENTS FOR SAME.
5. IRRIGATION PLANS SHALL HAVE PRECEDENCE OVER IRRIGATION SPECIFICATIONS. ANY
DISCREPANCIES BETWEEN THESE TWO DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF
THE IRRIGATION CONSULTANT BEFORE INSTALLATION.
6. IT IS THE INTENT TO KEEP IRRIGATION WATER OFF OF ALL BUILDINGS, SIDEWALKS AND PARKING AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FIELD TUNE EACH
SPRINKLER AS TO KEEPING IRRIGATION ADJUSTED TO GRASSED AND SEEDED AREAS ONLY. IT
WILL ALSO BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO SUPPLY THE OWNER
WITH AN OPERATING SCHEDULE THAT WORKS WITH EXISTING PLANS AND ANY FIELD
ADJUSTMENTS.
7. IT IS THE INTENT OF THE IRRIGATION DESIGN TO ACHIEVE HEAD TO HEAD COVERAGE IN ALL
GRASSED AND SEEDED AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION
CONTRACTOR TO ADJUST FOR SAME.
8. IRRIGATION PLANS ARE DIAGRAMMATIC IN NATURE CONTRACTOR WILL BE RESPONSIBLE FOR THE LOCATION OF ALL EQUIPMENT AS STAKED BY IRRIGATION CONSULTANT. SAID EQUIPMENT, WHEN FIELD LOCATED, MAY VARY FROM PROPOSED PLAN DUE TO SITE CONDITIONS AND
CONTRACTOR WILL MAKE ADJUSTMENTS ACCORDINGLY AT NO ADDITIONAL COST TO OWNER.
1. ALL PIPE FITTINGS SHALL BE OF FUSED HDPE E.F. OR F.M. RATED TYPE. ALL SPRINKLERS SHALL
BE MOUNTED WITH MANUFACTURER'S SWING JOINTS ON CMF GLOBAL FUSED HDPE SERVICE
RISERS. NO BRAND MIXING ALLOWED AND CONTRACTOR/EQUIPMENT TO BE SITE CERTIFIED BY
SUPPLIER AS SPECIFIED - NO EXCEPTIONS.
2. ALL PIPE SHALL BE CARRIED IN SEPARATE TRENCH.
NG
PG
P
8"
8"
4"
8"
4"
8"
8"
A A
A
A
8"
8"8"
8" 8" 8" 6"
6"
6"
4"
6"
4"
8"
8"
8"
6"
8"8"
6" 4"
6"
6"
4"
6"
6"
4" 6"
3"
6"
4"
D8"
D
6"
6"
4"
6"
6"
A
8"
8"
8"
8"
SCALE: NOT TO SCALE
TYPICAL HOLE
70'
70'
65'
65' x
70'
70'360 PE BALL VALVE WITH HDPE
EXTENSIONS
3"1" Q.C.V.
TEE SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE
AS PER STAKING
HDPE 4710 DR13.5 (UNLESS NOTED)
LATERAL PIPING
FAIRWAY SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
1" Q.C.V.
GREENS SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
SURROUND SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
ALL PIPE HDPE 4710 DR13.5 (UNLESS
NOTED)
360 PE BALL VALVE WITH HDPE
EXTENSIONS
3"
R.F. SATELLITE
220 V.A.C. POWER WIRE - SEE PLANS AND
GROUNDING DETAIL
HDPE 4710 DR13.5 MAIN LINE PIPING
3"
360 PE BALL VALVE WITH HDPE
EXTENSIONS
2"
2"
2"
2"
3"
HYDRAULIC PIPING PLAN
SCALE: 1" = 100'-0"NORTH
E R
IK
C
H R
IS
T
IA
N
SE
N
D E
SI
G
N G
R O
U P, L T
D
5T H
ST
T
DE
S M
OI
NE
S, IO
W A
5-
PH
ON
E
(5
) 2
-6
FA
X (5
) 2
-6
REVISIONS:
SHEET #:
D R
AW
IN
G T
IT
LE
SC
AL
E:
DATE:
DRAWN BY:
REVIEWED BY:
09/20/2024
PR
IN
TE
D
M
EA
D O
W
LA
K E
G O
LF
C
O U
R
SE
EN
ID
, O K
LI-2
H
YD
R A
U
LI
C P
IP
IN
G P
LA
N
1"
'-0
PC
EC
10.24.24
Z:
\C ol e' s Pr oj ec ts \M ea do w la ke \M ea do w la ke G
C .d w g
/2
1/
0:
:3
AM
Turf Rotor, 4.0" Pop-Up. Adjustable and Full Circle. Stainless Steel Riser. Drain Check Valve. Standard Nozzle.
Toro FLX34-348-2 Full-circle golf sprinkler, body inlet 1", ACME body threads, electric valve type w/ Spike Guard solenoid, pressure regulation at 80psi
Toro FLX35-358-2 Adjustable from 40 to 330 degrees, and 360 full circle. 1" inlet, ACME body threads, electric valve type w/ Spike Guard solenoid, pressure regulation at 80psi
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Toro P220G-27-04 Electric, 1" Plastic In-Line Remote Control Valve With EZ Reg Pressure Regulator.
Toro 474-00 One-Piece, 1" Single Lug Quick Coupler Valve with Standard Cover.
Clow Isolation Valve w/ HDPE Extensions
- Line Sized
Bermad C30 2" Air/Vacuum Relief Valve
(10) To Be Field Located By Irrigation Consultant
Aquafuse 360 PE Ball Valve - 2" 360 Degree PE valve with Position Indication and HDPE 4710 DR13.5 Extensions. Provide with Manufacturers 10" Round Valve Box
Drain/Fill Valve - Aquafuse 360 PE Ball Valve 2" 360 Degree PE valve with Position Indication and HDPE 4710 DR13.5 Extensions. Provide with Manufacturers 10" Round Valve Box
Toro G4-XXP6R4 Toro G4 OSMAC Satellite Controller w/ Plastic Green Cabinet, Radio Controls, Large Terminal Blocks, Switches & Premium Surge - See Plan For Station Counts.
Spectrum Watchdog Wireless/Solar Weather Station - Actual Location By Owner
Toro LX-04-5-21 Toro Lynx central control software w/ premium computer, (5) years NSN support, (4) maintenance radios and all associated equipment.
Existing Watertronics Pump Station 1
Irrigation Lateral Line: HDPE PE4710 DR 13.5 52,698 l.f.
Irrigation Mainline: HDPE PE4710 DR 13.5 20,594 l.f.
220vac Power Wire (Twisted Single Conductor - Red, Black, White, Green & #8 Bare Shielding Wire) - As Per Local Codes
Irrigation Zone Limits
Note: All Quantities Are For Reference Only. Contractor Responsible For Actual Counts.
A
D
X
XX
W
CC
P
LEGEND
DESIGN NOTES:
ELECTRICAL NOTES:
PLUMBING NOTES:
PROGRAMMING NOTES:
1. ALL 120 V.A.C. POWER SPLICES AT FIELD SATELLITES.
2. ALL POWER WIRE TAPS AND CONNECTIONS SHALL CONFORM TO ALL LOCAL AND STATE CODES
AND PERFORMED BY LICENSED ELECTRICIAN.
3. 24" LOOP OF WIRE LOCATED BELOW EACH HEAD.
4. ALL 24 V.A.C. SECONDARY WIRING SHALL BE (RED) #14 HOT AND (WHITE) #12 COMMON. (ONE HOT
WIRE PER HEAD)
5. ALL WIRE SHALL HAVE ENOUGH SLACK AS TO ACCOMMODATE FOR EXPANSION AND/OR
CONTRACTION.
6. ALL WIRE TO BE UL APPROVED FOR DIRECT BURIAL.
7. ALL 120 V.A.C. PRIMARY, AND 24 V.A.C. SECONDARY POWER TO BE INSTALLED AS PER STATE AND LOCAL CODES. SIZED AS PER PLAN WITH GROUND WIRE; MEETING N.E.C. REQUIREMENTS.
8. TWO SPARE HOT (#14) WIRE TO EACH GREEN AND ONE SPARE HOT (#14) TO WIRE TO EACH TEE
COMPLEX AND MARKED AS SPACE (BLUE IN COLOR).
1. FIELD SATELLITES SHALL CARRY APPROPRIATE STATION CARDS FOR INDIVIDUAL HEAD
CONTROL OF ALL SPRINKLERS.
2. ALL SPRINKLERS SHALL HAVE ONE WIRE (HOT 24 V.A.C.) TO RESPECTIVE FIELD SATELLITE.
3. ALL SATELLITE LOCATIONS SHALL BE IN ACCORDANCE WITH RAIN FALL SURVEYS AND OUT OF
100 YEAR FLOOD PLAIN.
SATELLITE NUMBER
APPROXIMATE STATION COUNT
XX
X
1. ALL PRODUCT APPLICATIONS AND INSTALLATIONS MUST MEET MANUFACTURER'S
REQUIREMENTS.
2. FLOW RATES THROUGH HDPE PIPING NOT TO EXCEED MANUFACTURER'S RECOMMENDATIONS.
3. PIPING AS SHOWN IS DIAGRAMMATIC IN NATURE. ALL PIPING TO BE LOCATED WITHIN OWNER'S
PROPERTY LINES.
4. CONTRACTOR IS RESPONSIBLE FOR PROPER OPERATION OF IRRIGATION SYSTEM. SYSTEM
SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATIONS AND SHALL WATER ALL SEEDED
AND SODDED AREAS NOTED. IRRIGATION PLAN IS INTENDED TO INCLUDE EVERYTHING
NECESSARY TO THE PROPER OPERATION OF SAID IRRIGATION SYSTEM. IF ADJUSTMENTS ARE
REQUIRED, CONTRACTOR SHALL MAKE ADJUSTMENTS FOR SAME.
5. IRRIGATION PLANS SHALL HAVE PRECEDENCE OVER IRRIGATION SPECIFICATIONS. ANY
DISCREPANCIES BETWEEN THESE TWO DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF
THE IRRIGATION CONSULTANT BEFORE INSTALLATION.
6. IT IS THE INTENT TO KEEP IRRIGATION WATER OFF OF ALL BUILDINGS, SIDEWALKS AND PARKING AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FIELD TUNE EACH
SPRINKLER AS TO KEEPING IRRIGATION ADJUSTED TO GRASSED AND SEEDED AREAS ONLY. IT
WILL ALSO BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO SUPPLY THE OWNER
WITH AN OPERATING SCHEDULE THAT WORKS WITH EXISTING PLANS AND ANY FIELD
ADJUSTMENTS.
7. IT IS THE INTENT OF THE IRRIGATION DESIGN TO ACHIEVE HEAD TO HEAD COVERAGE IN ALL
GRASSED AND SEEDED AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION
CONTRACTOR TO ADJUST FOR SAME.
8. IRRIGATION PLANS ARE DIAGRAMMATIC IN NATURE CONTRACTOR WILL BE RESPONSIBLE FOR THE LOCATION OF ALL EQUIPMENT AS STAKED BY IRRIGATION CONSULTANT. SAID EQUIPMENT, WHEN FIELD LOCATED, MAY VARY FROM PROPOSED PLAN DUE TO SITE CONDITIONS AND
CONTRACTOR WILL MAKE ADJUSTMENTS ACCORDINGLY AT NO ADDITIONAL COST TO OWNER.
1. ALL PIPE FITTINGS SHALL BE OF FUSED HDPE E.F. OR F.M. RATED TYPE. ALL SPRINKLERS SHALL
BE MOUNTED WITH MANUFACTURER'S SWING JOINTS ON CMF GLOBAL FUSED HDPE SERVICE
RISERS. NO BRAND MIXING ALLOWED AND CONTRACTOR/EQUIPMENT TO BE SITE CERTIFIED BY
SUPPLIER AS SPECIFIED - NO EXCEPTIONS.
2. ALL PIPE SHALL BE CARRIED IN SEPARATE TRENCH.
NG
PG
P
CC
CENTRAL, PUMP STATION, WEATHER
STATION, AND MAINTENANCE RADIO
ANTENNAS - ACTUAL LOCATION BY
OWNER
W
1/8
64 10
12/11
13/14
14/15
DR
#8 220vac
#8 220vac
#8 220vac #6 220vac#4
220vac
#6 220vac
#6 220vac
#6 220vac
#8 220vac
#8 220vac
#10 220vac
#10 220vac
#4 220vac
#6 220vac
#6 220vac
#6 220vac
#8 220vac
#8 220vac
#6 220vac
#8 220vac
#8 220vac
#6 220vac
#6 220vac
SCALE: NOT TO SCALE
TYPICAL HOLE
70'
70'
65'
65' x
70'
70'360 PE BALL VALVE WITH HDPE
EXTENSIONS
3"1" Q.C.V.
TEE SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE
AS PER STAKING
HDPE 4710 DR13.5 (UNLESS NOTED)
LATERAL PIPING
FAIRWAY SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
1" Q.C.V.
GREENS SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
SURROUND SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
ALL PIPE HDPE 4710 DR13.5 (UNLESS
NOTED)
360 PE BALL VALVE WITH HDPE
EXTENSIONS
3"
R.F. SATELLITE
220 V.A.C. POWER WIRE - SEE PLANS AND
GROUNDING DETAIL
HDPE 4710 DR13.5 MAIN LINE PIPING
3"
360 PE BALL VALVE WITH HDPE
EXTENSIONS
2"
2"
2"
2"
3"
ELECTRICAL SCHEMATIC PLAN
SCALE: 1" = 100'-0"NORTH
E R
IK
C
H R
IS
T
IA
N
SE
N
D E
SI
G
N G
R O
U P, L T
D
5T H
ST
T
DE
S M
OI
NE
S, IO
W A
5-
PH
ON
E
(5
) 2
-6
FA
X (5
) 2
-6
REVISIONS:
SHEET #:
D R
AW
IN
G T
IT
LE
SC
AL
E:
DATE:
DRAWN BY:
REVIEWED BY:
09/20/2024
PR
IN
TE
D
M
EA
D O
W
LA
K E
G O
LF
C
O U
R
SE
EN
ID
, O K
LI-3
EL
EC
TR
IC
A L
SC
H
EM
A
TI
C
PL
A
N 1"
'-0
PC
EC
10.24.24
Z:
\C ol e' s Pr oj ec ts \M ea do w la ke \M ea do w la ke G
C .d w g
/2
1/
0:
:3
AM
Turf Rotor, 4.0" Pop-Up. Adjustable and Full Circle. Stainless Steel Riser. Drain Check Valve. Standard Nozzle.
Toro FLX34-348-2 Full-circle golf sprinkler, body inlet 1", ACME body threads, electric valve type w/ Spike Guard solenoid, pressure regulation at 80psi
Toro FLX35-358-2 Adjustable from 40 to 330 degrees, and 360 full circle. 1" inlet, ACME body threads, electric valve type w/ Spike Guard solenoid, pressure regulation at 80psi
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Toro P220G-27-04 Electric, 1" Plastic In-Line Remote Control Valve With EZ Reg Pressure Regulator.
Toro 474-00 One-Piece, 1" Single Lug Quick Coupler Valve with Standard Cover.
Clow Isolation Valve w/ HDPE Extensions
- Line Sized
Bermad C30 2" Air/Vacuum Relief Valve
(10) To Be Field Located By Irrigation Consultant
Aquafuse 360 PE Ball Valve - 2" 360 Degree PE valve with Position Indication and HDPE 4710 DR13.5 Extensions. Provide with Manufacturers 10" Round Valve Box
Drain/Fill Valve - Aquafuse 360 PE Ball Valve 2" 360 Degree PE valve with Position Indication and HDPE 4710 DR13.5 Extensions. Provide with Manufacturers 10" Round Valve Box
Toro G4-XXP6R4 Toro G4 OSMAC Satellite Controller w/ Plastic Green Cabinet, Radio Controls, Large Terminal Blocks, Switches & Premium Surge - See Plan For Station Counts.
Spectrum Watchdog Wireless/Solar Weather Station - Actual Location By Owner
Toro LX-04-5-21 Toro Lynx central control software w/ premium computer, (5) years NSN support, (4) maintenance radios and all associated equipment.
Existing Watertronics Pump Station 1
Irrigation Lateral Line: HDPE PE4710 DR 13.5 52,698 l.f.
Irrigation Mainline: HDPE PE4710 DR 13.5 20,594 l.f.
220vac Power Wire (Twisted Single Conductor - Red, Black, White, Green & #8 Bare Shielding Wire) - As Per Local Codes
Irrigation Zone Limits
Note: All Quantities Are For Reference Only. Contractor Responsible For Actual Counts.
A
D
X
XX
W
CC
P
LEGEND
DESIGN NOTES:
ELECTRICAL NOTES:
PLUMBING NOTES:
PROGRAMMING NOTES:
1. ALL 120 V.A.C. POWER SPLICES AT FIELD SATELLITES.
2. ALL POWER WIRE TAPS AND CONNECTIONS SHALL CONFORM TO ALL LOCAL AND STATE CODES
AND PERFORMED BY LICENSED ELECTRICIAN.
3. 24" LOOP OF WIRE LOCATED BELOW EACH HEAD.
4. ALL 24 V.A.C. SECONDARY WIRING SHALL BE (RED) #14 HOT AND (WHITE) #12 COMMON. (ONE HOT
WIRE PER HEAD)
5. ALL WIRE SHALL HAVE ENOUGH SLACK AS TO ACCOMMODATE FOR EXPANSION AND/OR
CONTRACTION.
6. ALL WIRE TO BE UL APPROVED FOR DIRECT BURIAL.
7. ALL 120 V.A.C. PRIMARY, AND 24 V.A.C. SECONDARY POWER TO BE INSTALLED AS PER STATE AND LOCAL CODES. SIZED AS PER PLAN WITH GROUND WIRE; MEETING N.E.C. REQUIREMENTS.
8. TWO SPARE HOT (#14) WIRE TO EACH GREEN AND ONE SPARE HOT (#14) TO WIRE TO EACH TEE
COMPLEX AND MARKED AS SPACE (BLUE IN COLOR).
1. FIELD SATELLITES SHALL CARRY APPROPRIATE STATION CARDS FOR INDIVIDUAL HEAD
CONTROL OF ALL SPRINKLERS.
2. ALL SPRINKLERS SHALL HAVE ONE WIRE (HOT 24 V.A.C.) TO RESPECTIVE FIELD SATELLITE.
3. ALL SATELLITE LOCATIONS SHALL BE IN ACCORDANCE WITH RAIN FALL SURVEYS AND OUT OF
100 YEAR FLOOD PLAIN.
SATELLITE NUMBER
APPROXIMATE STATION COUNT
XX
X
1. ALL PRODUCT APPLICATIONS AND INSTALLATIONS MUST MEET MANUFACTURER'S
REQUIREMENTS.
2. FLOW RATES THROUGH HDPE PIPING NOT TO EXCEED MANUFACTURER'S RECOMMENDATIONS.
3. PIPING AS SHOWN IS DIAGRAMMATIC IN NATURE. ALL PIPING TO BE LOCATED WITHIN OWNER'S
PROPERTY LINES.
4. CONTRACTOR IS RESPONSIBLE FOR PROPER OPERATION OF IRRIGATION SYSTEM. SYSTEM
SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATIONS AND SHALL WATER ALL SEEDED
AND SODDED AREAS NOTED. IRRIGATION PLAN IS INTENDED TO INCLUDE EVERYTHING
NECESSARY TO THE PROPER OPERATION OF SAID IRRIGATION SYSTEM. IF ADJUSTMENTS ARE
REQUIRED, CONTRACTOR SHALL MAKE ADJUSTMENTS FOR SAME.
5. IRRIGATION PLANS SHALL HAVE PRECEDENCE OVER IRRIGATION SPECIFICATIONS. ANY
DISCREPANCIES BETWEEN THESE TWO DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF
THE IRRIGATION CONSULTANT BEFORE INSTALLATION.
6. IT IS THE INTENT TO KEEP IRRIGATION WATER OFF OF ALL BUILDINGS, SIDEWALKS AND PARKING AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FIELD TUNE EACH
SPRINKLER AS TO KEEPING IRRIGATION ADJUSTED TO GRASSED AND SEEDED AREAS ONLY. IT
WILL ALSO BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO SUPPLY THE OWNER
WITH AN OPERATING SCHEDULE THAT WORKS WITH EXISTING PLANS AND ANY FIELD
ADJUSTMENTS.
7. IT IS THE INTENT OF THE IRRIGATION DESIGN TO ACHIEVE HEAD TO HEAD COVERAGE IN ALL
GRASSED AND SEEDED AREAS. IT WILL BE THE RESPONSIBILITY OF THE IRRIGATION
CONTRACTOR TO ADJUST FOR SAME.
8. IRRIGATION PLANS ARE DIAGRAMMATIC IN NATURE CONTRACTOR WILL BE RESPONSIBLE FOR THE LOCATION OF ALL EQUIPMENT AS STAKED BY IRRIGATION CONSULTANT. SAID EQUIPMENT, WHEN FIELD LOCATED, MAY VARY FROM PROPOSED PLAN DUE TO SITE CONDITIONS AND
CONTRACTOR WILL MAKE ADJUSTMENTS ACCORDINGLY AT NO ADDITIONAL COST TO OWNER.
1. ALL PIPE FITTINGS SHALL BE OF FUSED HDPE E.F. OR F.M. RATED TYPE. ALL SPRINKLERS SHALL
BE MOUNTED WITH MANUFACTURER'S SWING JOINTS ON CMF GLOBAL FUSED HDPE SERVICE
RISERS. NO BRAND MIXING ALLOWED AND CONTRACTOR/EQUIPMENT TO BE SITE CERTIFIED BY
SUPPLIER AS SPECIFIED - NO EXCEPTIONS.
2. ALL PIPE SHALL BE CARRIED IN SEPARATE TRENCH.
NG
PG
P
8"
8"
4"
8"
4"
8"
8"
A A
A
A
8"
8"8"
8" 8" 8" 6"
6"
6"
4"
6"
4"
8"
8"
8"
6"
8"8"
6" 4"
6"
6"
4"
6"
6"
4" 6"
3"
6"
4"
CC
CENTRAL, PUMP STATION, WEATHER
STATION, AND MAINTENANCE RADIO
ANTENNAS - ACTUAL LOCATION BY
OWNER
W
D8"
D
1/8
6"
6"
32 4"
64 10
12/11
13/14
14/15
6"17
DR
6"
A
#8 220vac
#8 220vac
#8 220vac #6 220vac#4
220vac
#6 220vac
8"
#6 220vac
8" #6
220vac
#8 220vac
8"
#8 220vac
#10 220vac
#10 220vac
#4 220vac
#6 220vac
#6 220vac
#6 220vac
#8 220vac
#8 220vac
#6 220vac
#8 220vac
#8 220vac
#6 220vac
#6 220vac
8"
SCALE: NOT TO SCALE
TYPICAL HOLE
70'
70'
65'
65' x
70'
70'360 PE BALL VALVE WITH HDPE
EXTENSIONS
3"1" Q.C.V.
TEE SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE
AS PER STAKING
HDPE 4710 DR13.5 (UNLESS NOTED)
LATERAL PIPING
FAIRWAY SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
1" Q.C.V.
GREENS SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
SURROUND SPRINKLER NOZZLES AND
SPACING SUBJECT TO CHANGE AS
PER STAKING
ALL PIPE HDPE 4710 DR13.5 (UNLESS
NOTED)
360 PE BALL VALVE WITH HDPE
EXTENSIONS
3"
R.F. SATELLITE
220 V.A.C. POWER WIRE - SEE PLANS AND
GROUNDING DETAIL
HDPE 4710 DR13.5 MAIN LINE PIPING
3"
360 PE BALL VALVE WITH HDPE
EXTENSIONS
2"
2"
2"
2"
3"
SITE IRRIGATION PLAN
SCALE: 1" = 100'-0"NORTH
E R
IK
C
H R
IS
T
IA
N
SE
N
D E
SI
G
N G
R O
U P, L T
D
5T H
ST
T
DE
S M
OI
NE
S, IO
W A
5-
PH
ON
E
(5
) 2
-6
FA
X (5
) 2
-6
REVISIONS:
SHEET #:
D R
AW
IN
G T
IT
LE
SC
AL
E:
DATE:
DRAWN BY:
REVIEWED BY:
09/20/2024
PR
IN
TE
D
M
EA
D O
W
LA
K E
G O
LF
C
O U
R
SE
EN
ID
, O K
LI-4
SI
TE
IR
R
IG
A
TI
O
N P
LA
N
1"
'-0
PC
EC
10.24.24
Z:
\C ol e' s Pr oj ec ts \M ea do w la ke \M ea do w la ke G
C .d w g
/2
1/
0:
:3
AM
ROAD CROSSING DETAIL
SCALE: NOT TO SCALE
SEE SPECS.
SEE SPECS.
6" 6"
6" MIN.
6" 6"
MIN. MIN. MIN. MIN.
PEDESTAL-MOUNT CONTROLLER
TORO R.F. G4 OSMAC
SCALE: NOT TO SCALE
DRAIN/FILL VALVE DETAIL
SCALE: NOT TO SCALE
SINGLE LARGE TURF GEARED ROTOR
SCALE: NOT TO SCALE SCALE: NOT TO SCALE
BRIDGE CROSSING DETAIL
SCALE: NOT TO SCALE
AIR RELEASE VALVE ASSEMBLY
SCALE: NOT TO SCALE
SINGLE QUICK-COUPLING VALVE
WITH STABILIZER
SCALE: NOT TO SCALE
(3" OR LARGER)
CAST IRON VALVE DETAIL
STREAM CROSSING DETAIL
SCALE: NOT TO SCALE
MIN.
4'-0"
3'-0"
MIN.
2'-0" MIN.
6'-0"
MIN.
AquaFuse SOCKET FUSION
COUPLING
AquaFuse CONTROLFLO
PE X PE BALL VALVE
HDPE RISER CUT TO FIT
AquaFuse SOCKET FUSION
90° ELBOW
3" MINIMUM DEPTH OF
3/4" WASHED GRAVEL
HDPE PIPE TO RELIEF
POINT - DAYLIGHT (SEE PLAN)
HDPE MAIN LINE
AquaFuse SQUARE OR ROUND
BASE BRANCH SADDLE
PVC SLEEVE
NOTCH PIPE TO FIT VALVE
VALVE BOX
FINISH GRADE
STREET
FUSED DR11 HDPE 4710FUSED DR11 HDPE 4710
HDPE MAINHDPE MAIN
HDPE PIPING
FUSED AS PER HDPE
DR11 4710 PIPING
FUSED AS PER HDPE
DR11 4710 PIPING
STAINLESS STEEL HANGERS AT 2'-0"
O.C. OR AS REQUIRED FOR ENGINEERED
WEIGHT LOAD
PREFABRICATED FUSED HDPE
PIPING
FUSED SIZE AS PER
HDPE DR11 4710
PIPING
FUSED SIZE AS PER
HDPE DR11 4710
PIPING
NOTE:
ALL STREAM CROSSINGS SHALL BE PERFORMED IN
ACCORDANCE WITH ALL GOVERNING BODIES. CONTRACTOR WILL
BE RESPONSIBLE FOR ALL COSTS INCURRED AS THEY PERTAIN
TO SAID CROSSINGS.
NOTE:
ALL 120 V.A.C AND 24 V.A.C. SHALL BE CARRIED IN SEPARATE
PVC CLASS 315 SLEEVES. ALL SLEEVES SHALL BE INSTALLED
AS PER LOCAL, STATE AND FEDERAL CODES.
OVERALL ASSEMBLY LENGTH
3" MINIMUM DEPTH OF
3/4" WASHED GRAVEL
SE
E
SP
EC
IF
IC
AT
IO
N S
FO
R
D
EP
TH
CONTROLFLO GATE VALVE WITH
BUTT FUSION STUB ENDS
MODEL #AF2638
PVC SLEEVE
NOTCH PIPE TO FIT VALVE
VALVE BOX
FINISH GRADE
HDPE MAIN LINE PIPE
AQUAFUSE FUSIBLE HDPE
SERVICE SADDLE WITH
FEMALE ACME OUTLET
PART NUMBERS: 2"
AFAS15-020 3"
AFAS15-030 63mm AFAS15-063 75mm AFAS15-075 90mm
AFAS15-090
HDPE MAINLINE PIPE
AQUAFUSE FUSIBLE HDPE
SERVICE SADDLE WITH
FEMALE ACME OUTLETMANUFACTURED SWING JOINT
NOTE:
TO BE LOCATED AT HIGH POINTS
ON GOLF COURSE IRRIGATION
MAINS AND APPROVED BY
IRRIGATION CONSULTANT.
VALVE BOX WITH COVER
FINISH GRADE
QUICK-COUPLING VALVE:
INSTALLED AT HEIGHT TO
ALLOW
KEY HANDLE TO CLEAR BOX
3" MINIMUM DEPTH OF
3/4" WASHED GRAVEL
BRICK (1 OF 2)
QUICK COUPLER ANCHOR
HARCO PT# 82202
SCH. 80 NIPPLE
(LENGTH AS REQUIRED)
NOTE:
FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL
TO NOMINAL QUICK COUPLING VALVE INLET SIZE.
SWING JOINT INSTALLATION NOTE:
1. ACME O-RING SEALED THREADS ARE TO BE
FINGER TIGHTENED AND "BACKED OFF" ONE FULL
ROTATION BEFORE INSTALLATION.
2. THE SWING JOINT LAY ARM IS TO BE
INSTALLED AT AN ANGLE BETWEEN 30° AND 45°.
SWING JOINT IS REQUIRED
TO HAVE THE "M" INLET
CONNECTION (MALE ACME
THREAD)
MANUFACTURED SWING
JOINT
INSTALLATION NOTES: CUT PIPE END SQUARE AND
BEVEL AT 15° TO 20° FOR PROPER INSERTING.
MARK PIPE TO INDICATE PROPER INSERTION
DEPTH. APPLY APPROVED PIPE LUBRICANT FROM
END TO PIPE INSERTION DEPTH (REFERENCE
MARK). INSERT PIPE INTO TAP'T COUPLING UNTIL
MARK REACHES GASKET.
12" SWING
(SIDE VIEW)
PRESSURIZED MAIN OR
LATERAL PIPE
NOTE: INSTALL SPRINKLER
AT FINISHED GRADE
APPROVED BACKFILL
MANUFACTURED SWING
JOINT (AS SPECIFIED)
LAY LENGTH AS PER
LATERAL DEPTH AND
MANUFACTURES
INSTRUCTIONS
30°-40°
GRAVEL SUMP
CONCRETE FOOTING
SLOPE TO DRAIN
FINISHED SURFACE
RIGHT-SIDE
SECTION/ELEVATION
FRONT
SECTION/ELEVATION
CONDUIT FOR VALVE WIRES
CONDUIT FOR GROUND
(SEE DETAIL)
220/110V CONDUIT WITH
CONDUCTORS PER LOCAL
AND NATIONAL ELECTRICAL
CODES
CONDUIT FOR SUMP
IRRIGATION CONTROLLER
SEE PLAN FOR NUMBER
OF STATIONS.
CONNECTION LOCATED
IN VALVE BOX
CONNECTION
LOCATED IN
VALVE BOX
VALVE BOX WITH
LID/GRATE
POWER CABLE (PAIGE WIRE TRAY CABLE)
- MIN. WIRE SEPARATION FROM ALL
COMMUNICATION AND SECONDARY
WIRING AS PER CODE(S).
POWER WARNING TAPE
NOTE: MIN. VALVE WIRES
SEPARATION FROM ALL
COMMUNICATION CABLE - AS
REQUIRED. COMM. CABLES AS PER
MANUFACTURES RECOMMENDATIONS.
COMMUNICATION CABLE - AS
REQUIRED AND AS PER
MANUFACTURES RECOMMENDATIONS
PIPE
NOTES:
1. CONNECT ALL 6 AWG WIRES INSIDE THE
CONTROLLER. CONNECT ONE WIRE TO THE
CONTROLLER GROUND LUG AND USE A #4 SPLIT
BOLT TO CONNECT ALL WIRES TOGETHER.
2. MAKE SURE THAT THE EARTH CONTACT MATERIAL
COMPLETELY COVERS THE WELD JOINT OF THE
GROUND PLATE. THE GREEN/YELLOW WIRE INSULATION
SHOULD BE COVERED BY THE EARTH CONTACT
MATERIAL.
SPHERE OF INFLUENCE
SE
E
SP
EC
S
WIRES AND CABLES
POWER WIRING (120 VAC OR 220 VAC):
ALL POWER CABLES ARE TYPE TRAY CABLE; THEY ARE TO BE UL LISTED FOR DIRECT BURIAL, AND RATED AT 600 VOLTS. THE CABLE SHALL INCLUDE THREE CONDUCTORS, WHICH ARE TO BE
COLORED PER WIRE INDUSTRY STANDARD OR NUMBERED AS 1, 2, AND 3. THE SIZE OF THE
"HOT" AND "COMMON" CONDUCTORS ARE TO BE AS SHOWN ON THE IRRIGATION PLANS, AND THE
SIZE OF THE "GROUND" CONDUCTOR AS REQUIRED BY THE NATIONAL ELECTRICAL CODE, OR
LARGER. THE INNER COPPER CONDUCTORS SHALL ARE TO BE COVERED WITH HIGH DIELECTRIC
PVC AND NYLON. THE OUTER JACKET WILL BE BLACK PVC AND IS TO BE SUNLIGHT RESISTANT.
[PAIGE ELECTRIC CO., LP SPECIFICATION NUMBER P7266D FOR 10 AWG AND SMALLER AND
SPECIFICATION NUMBER P7267D FOR 8 AWG AND LARGER.]
CONTROL VALVE WIRING (24 VOLT AC, NOMINAL):
WIRES CONNECTING THE REMOTE CONTROL VALVES TO THE IRRIGATION CONTROLLER ARE SINGLE
CONDUCTORS, TYPE PE. ITS CONSTRUCTION INCORPORATES A SOLID COPPER CONDUCTOR AND
POLYETHYLENE (PE) INSULATION WITH A MINIMUM THICKNESS OF 0.045 INCHES. THE WIRES
SHALL BE UL LISTED FOR DIRECT BURIAL IN IRRIGATION SYSTEMS AND BE RATED AT A MINIMUM
OF 30 VAC. WIRE SIZES AND COLORS ARE DEFINED IN THE IRRIGATION PLANS AND OTHER
SPECIFICATIONS. [PAIGE ELECTRIC CO., LP SPECIFICATION NUMBER P7079D.]
SIDE VIEW
TOP VIEW
COPPER GROUND PLATE
4" X 8'-0"
GROUND ROD
8" X 10'-0"
6 AWG SOLID BARE
COPPER WIRES
C
8'-0"
10'-0"
'-0
DEDICATED PLASTIC
SWEEP ELL
(1 1/2" OR LARGER)
CADWELD
CONNECTION
EARTH CONTACT
MATERIAL
GROUND ROD
COPPER GROUND
PLATE
6 AWG SOLID BARE
COPPER WIRES
2'-6"
1'-0"
CONCRETE
PAD
CONTROLLER
THE COPPER GROUNDING PLATE ASSEMBLIES [PAIGE ELECTRIC PART NUMBER 182199L] MUST
MEET THE MINIMUM REQUIREMENTS OF ARTICLE 250-52(D) OF THE 1999 NEC. THEY ARE TO BE
MADE OF A COPPER ALLOY INTENDED FOR GROUNDING APPLICATIONS AND WILL HAVE MINIMUM
DIMENSIONS OF 4" X 96" X 0.0625". A 25-FOOT CONTINUOUS LENGTH (NO SPLICES ALLOWED UNLESS USING EXOTHERMIC WELDING PROCESS) OF 6 AWG SOLID BARE COPPER WIRE IS TO BE ATTACHED TO THE PLATE BY THE MANUFACTURER USING AN APPROVED WELDING PROCESS. THIS
WIRE IS TO BE CONNECTED TO THE ELECTRONIC EQUIPMENT GROUND LUG AS SHOWN IN THE
DETAIL. THE GROUND PLATE IS TO BE INSTALLED TO A MINIMUM DEPTH OF 30", AT A LOCATION
8 FEET FROM THE ELECTRONIC EQUIPMENT AND UNDERGROUND WIRES AND CABLES. TWO 50 -
POUND BAGS OF POWERSET ® [PAIGE ELECTRIC PART NUMBER 1820058] EARTH CONTACT MATERIAL MUST BE SPREAD SO THAT IT SURROUNDS THE COPPER PLATE EVENLY ALONG ITS LENGTH WITHIN A 6" WIDE TRENCH. SALTS, FERTILIZERS, BENTONITE CLAY, CEMENT, COKE, CARBON, AND OTHER CHEMICALS ARE NOT TO BE USED TO IMPROVE SOIL CONDUCTIVITY BECAUSE THESE MATERIALS
ARE CORROSIVE AND WILL CAUSE THE COPPER ELECTRODES TO ERODE AND BECOME LESS
EFFECTIVE WITH TIME.
INSTALL ALL GROUNDING CIRCUIT COMMONEST IN STRAIGHT LINES. WHEN NECESSARY TO MAKE
BENDS, DO NOT MAKE SHARP TURNS. TO PREVENT THE ELECTRODE-DISCHARGED ENERGY FROM
REENTERING THE UNDERGROUND WIRES AND CABLES, ALL ELECTRODES SHALL BE INSTALLED AWAY
FROM SAID WIRES AND CABLES. THE SPACING BETWEEN ANY TWO ELECTRODES SHALL BE AS
SHOWN IN THE DETAIL OF PAGE 1, SO THAT THEY DON'T COMPETE FOR THE SAME SOIL.
THE EARTH-TO-GROUND RESISTANCE OF THIS CIRCUIT TO BE MEASURED USING A MEGGER ®, OR
OTHER SIMILAR INSTRUMENTS, AND THE READING IS TO BE NO MORE THAT 10 OHMS. IF THE
RESISTANCE IS MORE THAN 10 OHMS, ADDITIONAL GROUND PLATES AND THE SOIL SURROUNDING
COPPER ELECTRODES BE KEPT AT A MINIMUM MOISTURE LEVEL OF 15% AT ALL TIMES BY
DEDICATING AN IRRIGATION STATION AT EACH CONTROLLER LOCATION. THE IRRIGATED AREA SHOULD
INCLUDE A CIRCLE WITH A 10-FOOT RADIUS AROUND THE GROUND ROD AND A RECTANGLE
MEASURING 1-FOOT X 24-FEET AROUND THE PLATE.
ALL UNDERGROUND CIRCUIT CONNECTIONS ARE TO BE MADE USING AN EXOTHERMIC WELDING
PROCESS BY UTILIZING PRODUCTS SUCH AS THE CADWELD "ONE-SHOT" KITS. SOLDER SHALL NOT
BE ALLOWED TO MAKE CONNECTIONS. IN ORDER TO ENSURE PROPER IGNITION OF THE
"ONE-SHOT", THE CADWELD T-320 IGNITER MUST BE UTILIZED [PAIGE ELECTRIC PART NUMBER 1820040.] THE 6 AWG BARE COPPER WIRES ARE TO BE INSTALLED IN AS STRAIGHT A LINE AS
POSSIBLE, AND IF IT IS NECESSARY TO MAKE A TURN OR A BEND IT SHALL BE DONE IN A
SWEEPING CURVE WITH A MINIMUM RADIUS OF 8" AND A MINIMUM INCLUDED ANGLE OF 90°.
MECHANICAL CLAMPS SHALL BE PERMITTED TEMPORARILY DURING THE RESISTANCE TEST PROCESS, BUT ARE TO BE REPLACED WITH CADWELD "ONE-SHOT" KITS IMMEDIATELY THEREAFTER.
GROUND RODS ARE TO HAVE A MINIMUM DIAMETER OF 5/8" AND A MINIMUM LENGTH OF 10
FEET. THESE ARE TO BE DRIVEN INTO THE GROUND IN A VERTICAL POSITION OR AN OBLIQUE ANGLE NOT TO EXCEED 45 DEGREES AT A LOCATION 10 FEET FROM THE ELECTRONIC EQUIPMENT, THE GROUND PLATE, OR THE WIRES AND CABLES CONNECTED TO SAID EQUIPMENT, AS SHOWN IN
THE DETAIL ABOVE. THE ROD IS TO BE STAMPED WITH THE UL LOGO [PAIGE ELECTRIC PART
NUMBER 1820037.] A 6 AWG SOLID BARE COPPER WIRE (ABOUT 12 FEET LONG) SHALL BE
CONNECTED TO THE ELECTRONIC EQUIPMENT GROUND LUG AS SHOWN IN THE DETAIL ABOVE.
EARTH GROUNDING
IT IS THE RESPONSIBILITY OF THE INSTALLER TO CONNECT ALL ELECTRONIC IRRIGATION
EQUIPMENT FOR WHICH HE IS RESPONSIBLE TO EARTH IN ACCORDANCE WITH ARTICLE 250 OF
THE NATIONAL ELECTRICAL CODE (NEC.) GROUNDING COMPONENTS WILL INCLUDE THE ITEMS
DESCRIBED IN THE FOLLOWING PARAGRAPHS, AT A MINIMUM.
USE GROUNDING ELECTRODES THAT ARE UL LISTED OR MANUFACTURED TO MEET THE MINIMUM
REQUIREMENTS OF ARTICLE 250-52 OF THE 2002 EDITION OF THE NEC. AT THE VERY MINIMUM, THE GROUNDING CIRCUIT WILL INCLUDE A COPPER CLAD STEEL GROUND ROD, A SOLID COPPER GROUND PLATE AND 100 POUNDS OF POWERSET ® EARTH CONTACT MATERIAL, AS DEFINED BELOW
AND PER THE FOLLOWING DETAIL.
SUPPLEMENTARY
GROUND
EARTH GROUND BY THE
UTILITY COMPANY
BONDING CONDUCTOR
GREEN OR BARE ( EQUIP. GRD)
WHITE (NEUTRAL)
BLACK (LINE OR HOT)
IRRIGATION
CONTROLLERPO
W
ER
S O
U R
C E
FR
O
M U
TI
LI
TY
C
O M
PA
N
Y
SERVICE
ENTRANCE
GROUND
BUS BAR
FUSE OR
CRKT. BRKR
THE BONDING CONDUCTORS ARE TO BE 6 AWG SOLID BARE COPPER UNLESS THE SYSTEM POWER
CONDUCTORS ARE LARGER THAT 1/0 AWG, IN WHICH CASE THEY ARE TO BE 4 AWG SOLID BARE
COPPER. ALL SPLICES TO THE BONDING CONDUCTORS SHALL BE MADE USING A CADWELD
"ONE-SHOT" KIT AS SHOWN IN THE DETAILS.
[PAIGE ELECTRIC PART NUMBER 1820074.]
BONDING
THE ABOVE GROUNDING CIRCUIT IS REFERRED-TO AS "SUPPLEMENTARY GROUNDING" IN THE NEC.
AND FOR SAFETY REASONS, THE NEC REQUIRES THAT ALL SUPPLEMENTARY GROUNDS BE
"BONDED" TO EACH OTHER AND TO THE SERVICE ENTRANCE GROUND (POWER SOURCE) AS
SHOWN IN THE DETAIL. THIS IS ALSO "RECOMMENDED PRACTICE " OF IEEE STANDARD 1100-1999.
NOTE THAT THIS IS IN ADDITION TO THE EQUIPMENT GROUND, WHICH IS COMMONLY REFERRED-TO AS "THE GREEN WIRE." THE BLACK, WHITE AND GREEN WIRES MUST ALWAYS BE KEPT TOGETHER
IN A TRENCH/CONDUIT/TRAY/ETC. SEE TRENCH DETAIL.
DISCLAIMER: EC DESIGN GROUP, LTD. HAS MADE EVERY EFFORT TO ENSURE THAT THE INFORMATION AND RECOMMENDATIONS CONTAINED WITHIN ARE CORRECT. HOWEVER, NEITHER EC DESIGN GROUP, LTD
NOR ANY OF ITS EMPLOYEES WARRANTS NOR ACCEPTS ANY LIABILITY FOR THE USE OF THIS
INFORMATION. NATIONAL AND LOCAL ELECTRICAL CODES SHOULD ALWAYS BE FOLLOWED. WIRING, GROUNDING, SHIELDING, AND BONDING IRRIGATION SYSTEMS COMPONENTS OFTEN REQUIRE COMPETENT ENGINEER JUDGMENT ON A CASE-BY-CASE BASIS. COMPETENT ENGINEERING ASSISTANCE SHOULD BE
SOUGHT FROM FIRMS SPECIALIZING IN THIS FIELD.
SWEEP BEND
CADWELD
PG11
CROSSTEE
90° ELLSTRAIGHT CONNECTION
WIRE STUB
WHEN JOINING BARE COPPER WIRES, DO SO USING AN ERICO PG11L "ONE-SHOT"
KIT AS SHOWN IN THE DETAILS.
[PAIGE ELECTRIC PART NUMBER 1820074.]
THE SHIELD NETWORK IS TO BE CONNECTED TO THE SERVICE ENTRANCE EARTH
GROUND, TO ALL ELECTRONIC EQUIPMENT GROUND LUGS, AND ALL EQUIPMENT
SUPPLEMENTARY GROUNDING ELECTRODES. ONE SUCH NETWORK IS NECESSARY
FOR EACH POWER SOURCE. DO NOT INTERCONNECT THE EQUIPMENT GROUND
WIRES FROM DIFFERENT POWER SOURCES.
8" MINIMUM
90°
NOTE: WHEN CONNECTING BARE COPPER WIRES TO
THE GROUND LUG OF ELECTRONIC EQUIPMENT, FEED
IT THROUGH A DEDICATED 1 1/2" PLASTIC SWEEP
ELL TO AUTOMATICALLY MEET THE REQUIREMENTS OF
THE "SWEEP BEND" SHOWN HERE.
THE BARE WIRE IS TO BE INSTALLED AS CLOSE TO THE SURFACE AS POSSIBLE,
YET BEING SUFFICIENTLY BELOW THE GROUND LEVEL AS TO PREVENT DAMAGE
FROM MAINTENANCE EQUIPMENT SUCH AS AERATORS. AND IT MUST BE PLACED
ABOVE ALL OTHER VALVE/ POWER/ COMMUNICATION WIRES AND CABLES, PER
DETAIL, AND INSTALLED IN ALL TRENCHES AS SHOWN ON THE ELECTRICAL PLAN
DRAWINGS. IT IS NOT NECESSARY TO INSTALL THIS CONDUCTOR OVER A SHORT
WIRE RUNS (LESS THAN 150 FEET) AWAY FROM THE MAIN WIRE BUNDLES. THE
CONDUCTOR IS LAID IN AS STRAIGHT A LINE AS POSSIBLE, AND WHEN NECESSARY
TO MAKE BENDS, DO SO IN A SWEEPING MOTION USING THE FOLLOWING DETAIL
AS A GUIDELINE.
SHIELDING
THE BONDING CONDUCTORS ARE TO BE INSTALLED IN SUCH A WAY SO THAT
THEY ALSO ACT AS SHIELDING CONDUCTORS. THIS BECOMES A NETWORK OF
SOLID BARE COPPER WIRE OVER ALL THE MAIN BUNDLES OF OTHER WIRES AND
CABLES AS SHOWN IN THE DETAIL.
DOUBLE HEAD SWING JOINT
SCALE: NOT TO SCALE
FOR GREENS/QCV'S
WEATHER STATION
SCALE: NOT TO SCALE
SOLAR POWERED
R.F. ANTENNA FROM WEATHER
STATION TO CENTRAL LOCATION
(MAINT. BLDG.)
GROUNDING DEVICE TO PROVIDE
10 OHMS RESISTANCE. SEE
GROUNDING PLATE DETAIL.
ALL STREAM CROSSINGS TO BE HORIZONTAL BORE
OF WIRE, COILED
3" MIN.
3.0-INCH MINIMUM DEPTH OF
3/4-INCH WASHED GRAVEL
LATERAL PIPE - 2" HDPE
CONTINUOUS BRICK (1 OF 4)
WATER PROOF CONNECTION
FINISH GRADE
JUMBO VALVE BOX
REMOTE CONTROL VALVE:
(SIZED AS PER PLAN)
(1 OF 2)
30-INCH LINEAR LENGTH
MAIN LINE PIPE
ISOLATION VALVE
SCALE: NOT TO SCALE
REMOTE CONTROL VALVE 1
E R
IK
C
H R
IS
T
IA
N
SE
N
D E
SI
G
N G
R O
U P, L T
D
5T H
ST
T
DE
S M
OI
NE
S, IO
W A
5-
PH
ON
E
(5
) 2
-6
FA
X (5
) 2
-6
REVISIONS:
SHEET #:
D R
AW
IN
G T
IT
LE
SC
AL
E:
DATE:
DRAWN BY:
REVIEWED BY:
09/20/2024
PR
IN
TE
D
M
EA
D O
W
LA
K E
G O
LF
C
O U
R
SE
EN
ID
, O K
LI-5
IR
R
IG
A
TI
O
N D
ET
A
IL
S
N O
N E
PC
EC
10.24.24
Z:
\C ol e' s Pr oj ec ts \M ea do w la ke \M ea do w la ke G
C .d w g
/2
1/
0:
:3
AM
AutoCAD SHX Text AquaFuse ELECTROFUSION
AutoCAD SHX Text
BRANCH SADDLE.
AutoCAD SHX Text AquaFuse ELECTROFUSION COUPLING
AutoCAD SHX Text
63MM OR 2".
AutoCAD SHX Text
2" HDPE PIPE CUT TO FIT.
AutoCAD SHX Text
JUMBO VALVE BOX.
AutoCAD SHX Text
HDPE MAINLINE.
AutoCAD SHX Text AquaFuse ELECTROFUSION
AutoCAD SHX Text
PE MALE TRANSITION FITTING.
AutoCAD SHX Text
AIR RELIEF VALVE 2".
AutoCAD SHX Text
SUPPORT BLOCK.
AutoCAD SHX Text
COUPLING 2".
AutoCAD SHX Text AquaFuse HDPE BALL VALVE
AutoCAD SHX Text
W/FUSED ENDS FOR PE PIPE
AutoCAD SHX Text
AND LEVER HANDLE.
AutoCAD SHX Text AquaSaddle
AutoCAD SHX Text
HDPE LATERAL LINE
AutoCAD SHX Text AquaFuse AF312-015 AquaSaddle (BELOW)
AutoCAD SHX Text
LASCO #305-015 DOUBLE SWING TEE
AutoCAD SHX Text
HDPE LATERAL LINE
AutoCAD SHX Text
XXX MANUFACTURED 1 " ACME 12" ACME INLET SWING JOINT
AutoCAD SHX Text
LASCO #305-015 DOUBLE SWING TEE
AutoCAD SHX Text
XXX MANUFACTURED 1 " ACME 12" ACME INLET SWING JOINT
AutoCAD SHX Text
TOP VIEW
AutoCAD SHX Text
SIDE VIEW
AquaFuse AF312-015
| Meadowlake GC Addendum #1.pdf |
| Sheets and Views |
| Meadowlake GC-LI-0 Cover |
| Meadowlake GC-LI-1 Impact |
| Meadowlake GC-LI-2 Hydraulic |
| Meadowlake GC-LI-3 Electric |
| Meadowlake GC-LI-4 Composite |
| Meadowlake GC-LI-5 Details |
File details come from the government source that posted it. Updated .