This Addendum Number 1 document modifies the procurement documents for the South Dakota Department of the Military's Replace Drill Floor Windows and Panels project at the Mitchell Armory (CFMO# 466443), issued by architect Colby McGinley on July 27, 2026. The addendum updates specifications for aluminum-framed storefronts and glazing systems to be installed in the drill floor windows and panels. Key changes include modifications to the aluminum storefront specifications in Section 08 8413, establishing center-set glazing position and mullion dimensions of 2 inches wide by 5 inches deep with a Dark Bronze finish. The glazing specifications in Section 08 8100 are updated to require laminated float annealed glass with a minimum thickness of 9/16 inch for inboard lites and laminated heat-strengthened float glass for spandrel units, both with a total thickness of 1 5/16 inch. The addendum also adds details to Drawing A101 (Main Level Floor Plan) and Drawing A806 (Details), including a new storefront jamb detail. Bids are due July 30, 2026 at 2:00 PM Central Time, and all bidders must acknowledge receipt of this addendum in their bid forms or face disqualification. The contractor will have 184 consecutive calendar days from the Notice to Proceed to complete the work, with liquidated damages assessed at $575 per day for delays.
The project scope encompasses demolition of the existing clerestory window system and installation of new aluminum storefront windows with insulated glass units and insulated spandrel glass units, along with treated wood blocking for a future reroof project, new prefinished metal flashing and brake metal, repair and repainting of existing wood soffits, and installation of new backer rod and sealant. All bids must be all-inclusive and complete; conditional or incomplete bids will be rejected. Puetz Design + Build serves as the Architect of Record and is not bidding on the project. The pre-bid meeting held on July 21, 2026 included representatives from the South Dakota Department of the Military and provided project overview information, with notes and an attendee sign-in sheet attached to the addendum. Bidders are required to coordinate with the owner regarding ongoing drill operations, typically occurring in the third week of the month, and maintain a clean construction area with thorough cleaning upon project completion. Employee access lists and federal background checks conducted at the state's expense are required, and all communications must be directed through Kelly Eitreim (South Dakota Department of the Military) and Colby McGinley (Architect).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Puetz Design + Build CFMO# 466443 SDNG Drill Floor Window & Panel Replacement
Addendum Number 1 00 9111-1
SECTION 00 9111
ADDENDUM NUMBER 1
PARTICULARS
DATE: JULY 27, 2026
BID DATE: JULY 30, 2026
PROJECT: REPLACE DRILL FLOOR WINDOWS AND PANELS
OWNER: SOUTH DAKOTA DEPARTMENT OF THE MILITARY
ARCHITECT: COLBY MCGINLEY
TO: PROSPECTIVE BIDDERS:
A. This Addendum forms a part of the Contract Documents and Modifies the Original Procurement Documents dated July 7, 2026 , with Amendments and Additions noted below.
B. Acknowledge Receipt of the Addendum in the space provided in the Bid Form . Failure to do so May Disqualify the Bidder.
C. Approvals of Products willl require full Compliance with the Specifications reguarding Product Performance.
GENERAL:
A. All bids must be submitted in accordance with Section 00 00 05 - Instructions to Bidders. No exceptions. If you have questions regarding the process by which you are to submit a bid, please contact Colby McGinley, Architect, for further direction.
B. Attendence sheet from Pre-Bid Meeting is attached for Reference.
C. Meeting Notes from Pre-Bid Meeting is attached for Reference.
IMPORTANT NOTICE
A. Bids shall be all inclusive. Conditional and incomplete bids will be rejected. Subcontractors and Material Suppliers who wish to submit proposals for specific items of work or materials, shall submit said proposal to a Bidder who is submitting a Complete Bid.
B. Puetz Design +Build is not bidding on this Project.
C. Bidders are encouraged to test out the online bidding process beforehand and make sure they have plenty of time to upload their bids. OSE can't help much if you call 1 hour beofre the bid opening with issues or difficulties.
1. Bidders can go in and edit their bid anytime before bid opening.
CHANGES TO THE PROJECT MANUAL - SPECIFICATIONS:
A. SECTION 08 8413 - Aluminum-Framed Storefronts
1. Update glazing position: Center-Set
2. Update mullion Dimensions: 2 inches wide by 5 inches deep
B. SECTION 08 8100 - Glazing
1. Updated Insultating Glass Units Inboard Lite:
a. Laminated float annealed glass, 9/16 inch thick minimum
b. Total Thickness: 1 5/16 inch
2. Updated Sprandrel Insultating Glass Units Inboard Lite:
a. Laminated Heat-strengthened float glass, 9/16 inch thick minimum
Puetz Design + Build CFMO# 466443 SDNG Drill Floor Window & Panel Replacement
Addendum Number 1 00 9111-2
b. Total Thickness: 1 5/16 inch
CHANGES TO DRAWINGS:
A. Drawing A101 - MAIN LEVEL FLOOR PLAN
1. Details added at window
2. Add keynote 7.15.
B. Drawing A806 - DETAILS
1. Detail added for Storefront Jamb
END OF ADDENDUM NUMBER 1
From: Colby McGinley
Date: 07/21/2026 (1:00pm CT)
Re: SD DOM – CFMO# 466443 – Replace Drill Floor Windows and Panels
Sign In Sheet
Introductions
Owner: SD Dept of the Military – Kelly Eitreim
Architect: Puetz Design + Build: Colby McGinley
Brief Overview of Project Scope & Information
• Demo of existing clerestory window system and installation of new Aluminum storefront windows.
• Aluminum Storefront windows with insulated glass units and insulated spandrel glass units.
• Additional treated wood blocking installed with the anticipation of a future reroof project.
• New prefinished metal flashing and brake metal.
• Repair and repaint existing wood soffit.
• New backer rod and sealant.
Discussion notes:
• The Contractor will have 184 consecutive calendar days to complete the work from the Notice to Proceed date.
• Puetz Design + Build is the Architect of Record and will not be bidding on or self-performing work on any portion of this project.
• Liquidated damages are $575/day, see specifications manual.
• The entire construction area must be kept clean and a thorough cleaning is required at the end of the project.
• There will be drill ongoing during construction, coordinate with the Owner (typically the 3rd week of the month).
• All communications go though Kelly and Colby.
• Employee access list will be required, a federal background check will be done at the State’s expense.
• Bidders are encouraged to get familiar with the Electronic Bid System prior to bid day.
• Bids opening date: July 30, 2026 at 2:00pm CT.
• Roof membrane must be protected at all times during construction
• Temporary enclosures/openings required during construction to keep building sealed from weather, dust, debris, and insects.
Pre-Bid Conference Agenda
08 43 13 – ALUMINUM-FRAMED STOREFRONTS 1 March 2022
08 43 13
ALUMINUM-FRAMED STOREFRONTS
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA CW-10 Care and Handling of Architectural Aluminum from Shop to Site: 2015
AAMA 609 & 610 Cleaning and Maintenance Guide for Architecturally Finished Aluminum (Combined
Document); 2015.
AAMA 611 Specification for Anodized Architectural Aluminum; 2024.
AAMA 2604 Voluntary Specification, Performance Requirements and Test Procedures for High
Performance Organic Coatings on Aluminum Extrusions and Panels (with Coil
Coating Appendix); 2022.
ASTM INTERNATIONAL (ASTM)
ASTM B209/B209M Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate; 2021a.
ASTM B221 Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes; 2021.
ASTM B221M Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric); 2021.
ASTM E283/E283M Standard Test Method for Determining Rate of Air Leakage Through Exterior
Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences
Across the Specimen; 2019.
ASTM E283 Standard Test Method for Determining the Rate of Air Leakage Through Exterior
Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the
Specimen; 2004 (Reapproved 2012).
ASTM E330/E330M Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference; 2014
(Reapproved 2021).
ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference; 2000 (Reapproved
2023).
1.2 SUBMITTALS
Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
A. Shop Drawings
1. Indicate system dimensions, framed opening requirements and tolerances, affected related work, expansion and contraction joint location and details, and field welding required.
B. Product Data
1. Provide component dimensions, describe components within assembly, anchorage and fasteners, glass and infill, internal drainage details.
C. Finish Samples
1. Submit two 6x6 inch in size illustrating funished aluminum surface, glass, infill panels, glazing materials
D. Manufacturer’s Certificate
1. Certify that the products supplied meet or exceed the specified requirements.
E. Design Data
1. Provide framing member structural and physical characteristics, engineering calculations, and dimensional limitations.
F. Manufacturer's Instructions for Installation
G. Quality Control Plan
H. Operation and Maintenance Data Cleaning and Maintenance
I. Warranty
1.3 QUALITY CONTROL
Submit Manufacturer Qualifications; company specializing in performing work of type specified and with at least three years of documented experience.
08 43 13 – ALUMINUM-FRAMED STOREFRONTS 2 March 2022
1.4 DELIVERY, STORAGE, AND HANDLING
A. Handle products of this section in accordance with AAMA CW-10.
B. Protect finished aluminum surfaces with wrapping. Do not use adhesive papers or sprayed coatings that bond to aluminum when exposed to sunlight or weather.
1.5 ENVIRONMENTAL REQUIREMENTS
Do not install sealants when ambient temperature is less than 40 degrees F. Maintain this minimum temperature during and 48 hours after installation.
1.6 WARRANTY
A. Correct defective Work within a five year period after Date of Substantial Completion
B. Provide five year manufacturer warranty against failure of glass seal on insulating glass units, including interpane dusting or misting. Include provision for replacement of failed units.
C. Provide five year manufacturer warranty against excessive degradation of exterior finish. Include provision for replacement of units with excessive fading, chalking, or flaking.
PART 2 PRODUCTS
2.1 MANUFACTURERS
Aluminum-Framed Storefronts
A. Kawneer North America
B. Manko Window Systems
C. CMI Architectural
D. Oldcastle Building Envelope
E. Tubelite USA Inc
2.2 ALUMINUM-FRAMED STOREFRONT
A. Aluminum-Framed Storefronts: Factory fabricated, factory finished aluminum framing members with infill, and related flashings, anchorage and attachment devices.
1. Glazing Position: Center-set.
2. Mullion Dimensions: 2 inches wide by 5 inches deep.
3. Finish Color: Dark Bronze
4. Fabrication: Joints and corners flush, hairline, and weatherproof, accurately fitted and secured; prepared to receive anchors and hardware; fasteners and attachments concealed from view; reinforced as required for imposed loads.
5. Construction: Eliminate noises caused by wind and thermal movement, prevent vibration harmonics, and prevent
"stack effect" in internal spaces.
6. System Internal Drainage: Drain to the exterior by means of a weep drainage network any water entering joints, condensation occurring in glazing channel, and migrating moisture occurring within system.
7. Expansion/ Contraction: Provide for expansion and contraction within system components caused by cycling temperature range of 170 degrees F over a 12 hour period without causing detrimental effect to system components, anchorages, and other building elements.
8. Movement: Allow for movement between storefront and adjacent construction, without damage to components or deterioration of seals.
9. Perimeter Clearance: Minimize space between framing members and adjacent construction while allowing expected movement.
10. Maintain continuous air barrier and/or vapor retarder seal throughout assembly, primarily in line with inside pane of glazing and inner sheet of infill panel, and heel bead of glazing compound.
B. Performance Requirements
1. Wind Loads: Design and size components to withstand the specified load requirements without damage or permanent set, when tested in accordance with ASTM E330/E330M, using loads 1.5 times the design wind loads and 10 second duration of maximum load.
a. Member Deflection: Limit member deflection to flexure limit of glass in any direction, with full recovery of glazing materials.
2. Water Penetration Resistance on Manufactured Assembly: No uncontrolled water on interior face, when tested in accordance with ASTM E331 at pressure differential of 8 psf.
3. Air Leakage: 0.06 cfm/sq ft maximum leakage of storefront wall area when tested in accordance with ASTM
E283/E283M at 1.57 psf pressure difference.
08 43 13 – ALUMINUM-FRAMED STOREFRONTS 3 March 2022
2.3 COMPONENTS
A. Aluminum Framing Members: Tubular aluminum sections, thermally broken with interior section insulated from exterior, drainage holes and internal weep drainage system. :
1. Framing members for interior applications need not be thermally broken.
2. Glazing Stops: Flush
3. Structurally Reinforced Members: Extruded aluminum with internal reinforcement of structural steel member.
B. Glazing: See Section 08 81 00.
2.4 MATERIALS
A. Extruded Aluminum: ASTM B221 (ASTM B221M).
B. Sheet Aluminum: ASTM B209/B209M.
C. Fasteners: Stainless steel.
D. Exposed Flashings: Aluminum sheet, 20 gauge, 0.032 inch minimum thickness; finish to match framing members.
E. Concealed Flashings: Galvanized steel, 26 gauge, 0.0179 inch minimum base metal thickness.
F. Sill Flashing Sealant: Elastomeric, silicone or polyurethane, compatible with flashing material.
G. Sealant for Setting Thresholds: Non-curing butyl type.
H. Perimeter Sealant: See Section 07 92 00
I. Glazing Gaskets: Type to suit application to achieve weather, moisture, and air infiltration requirements.
J. Shop and Touch-Up Primer for Steel Components: Zinc oxide, alkyd, linseed oil primer appropriate for use over hand cleaned steel.
2.5 FINISHES
A. Class I Color Anodized Finish: AAMA 611 AA-M12C22A42 Integrally colored anodic coating not less than 0.7 mils thick.
B. Color: Dark Bronze
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify dimensions, tolerances, and method of attachment with other work.
B. Verify that storefront wall openings and adjoining water-resistive and/or air barrier seal materials are ready to receive work in this section.
3.2 INSTALLATION
A. Install wall system in accordance with manufacturer's instructions.
B. Attach to structure to permit sufficient adjustment to accommodate construction tolerances and other irregularities.
C. Provide alignment attachments and shims to permanently fasten system to building structure.
D. Align assembly plumb and level, free of warp or twist. Maintain assembly dimensional tolerances, aligning with adjacent work.
E. Provide thermal isolation where components penetrate or disrupt building insulation.
F. Install sill flashings. Turn up ends and edges; seal to adjacent work to form water tight dam.
G. Where fasteners penetrate sill flashings, make watertight by seating and sealing fastener heads to sill flashing.
H. Use Low Expanding Spray insulation in shim spaces at perimeter of assembly to maintain continuity of thermal barrier.
I. Install glass and infill panels using glazing method required to achieve performance criteria; see Section 08 81
00.
J. Install perimeter sealant in accordance with Section 07 92 00.
K. Touch-up minor damage to factory applied finish; replace components that cannot be satisfactorily repaired.
3.3 TOLERANCES
A. Maximum Variation from Plumb: 0.06 inch per 3 feet non-cumulative or 0.06 inch per 10 feet, whichever is less.
B. Maximum Misalignment of Two Adjoining Members Abutting in Plane: 1/32 inch.
3.4 CLEANING
A. Remove protective material from pre-finished aluminum surfaces.
08 43 13 – ALUMINUM-FRAMED STOREFRONTS 4 March 2022
B. Wash down surfaces with a solution of mild detergent in warm water, applied with soft, clean wiping cloths, and take care to remove dirt from corners and to wipe surfaces clean.
C. Upon completion of installation, thoroughly clean aluminum surfaces in accordance with AAMA 609 & 610.
3.5 PROTECTION
A. Protect installed products from damage until Date of Substantial Completion.
-- END OF SECTION --
08 81 00 – GLAZING 1 March 2022
08 81 00
GLAZING
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 800 Voluntary Specifications and Test Methods for Sealants
AAMA GDSG-1 Glass Design for Sloped Glazing
AAMA TIR A7 Sloped Glazing Guidelines
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 Safety Glazing Materials Used in Buildings - Safety Performance Specifications and
Methods of Test
ASTM INTERNATIONAL (ASTM)
ASTM C509 Elastomeric Cellular Preformed Gasket and Sealing Material
ASTM C864 Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers
ASTM C920 Standard Specification for Elastomeric Joint Sealants
ASTM C1021 Standard Practice for Laboratories Engaged in Testing of Building Sealants
ASTM C1036 Standard Specification for Flat Glass
ASTM C1048 Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
ASTM C1087 Standard Test Method for Determining Compatibility of Liquid-Applied Sealants with
Accessories Used in Structural Glazing Systems
ASTM C1172 Standard Specification for Laminated Architectural Flat Glass
ASTM C1184 Standard Specification for Structural Silicone Sealants
ASTM C1281 Standard Specification for Preformed Tape Sealants for Glazing Applications
ASTM C1376 Standard Specification for Pyrolytic and Vacuum Deposition Coatings on Flat Glass
ASTM D395 Standard Test Methods for Rubber Property - Compression Set
ASTM D2287 Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds
ASTM D4802 Standard Specification for Poly (Methyl Methacrylate) Acrylic Plastic Sheet
ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound
Transmission Loss of Building Partitions and Elements
ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials
ASTM E413 Classification for Rating Sound Insulation
ASTM E1300 Standard Practice for Determining Load Resistance of Glass in Buildings
ASTM E2190 Standard Specification for Insulating Glass Unit Performance and Evaluation
ASTM E2226 Standard Practice for Application of Hose Stream
ASTM F1642/F1642M Standard Test Method for Glazing and Glazing Systems Subject to Airblast Loadings
ASTM F2912 Standard Specification for Glazing and Glazing Systems Subject to Airblast Loadings
GLASS ASSOCIATION OF NORTH AMERICA (GANA)
GANA Glazing Manual Glazing Manual
GANA Sealant Manual Sealant Manual
GANA Standards Manual Engineering Standards Manual
INSULATING GLASS MANUFACTURERS ALLIANCE (IGMA)
IGMA TB-1200 Guidelines for Insulating Glass Dimensional Tolerances
IGMA TB-3001 Guidelines for Sloped Glazing
IGMA TM-3000 North American Glazing Guidelines for Sealed Insulating Glass Units for Commercial
& Residential Use
NATIONAL FENESTRATION RATING COUNCIL (NFRC)
NFRC 100 Procedure for Determining Fenestration Product U-Factors
NFRC 200 Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and
Visible Transmittance at Normal Incidence
08 81 00 – GLAZING 2 March 2022
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 80 Standard for Fire Doors and Other Opening Protectives
NFPA 251 Standard Methods of Tests of Fire Resistance of Building Construction and Materials
NFPA 252 Standard Methods of Fire Tests of Door Assemblies
NFPA 257 Standard on Fire Test for Window and Glass Block Assemblies
U.S. DEPARTMENT OF ENERGY (DOE)
Energy Star Energy Star Energy Efficiency Labeling System (FEMP)
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
16 CFR 1201 Safety Standard for Architectural Glazing Materials
UNDERWRITERS LABORATORIES (UL)
UL 752 Standard for Bullet-Resisting Equipment
UL MEAPD Mechanical Equipment and Associated Products Directory (online version is listed under Certifications at www.ul.com)
1.2 SUBMITTALS
Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
A. SD-03 Product Data
1. Insulating Glass
2. Plastic Glazing
3. Glazing Accessories
4. Sealants
5. Joint Backer
B. SD-04 Samples
1. Insulating Glass
2. Plastic Sheet Glazing Compound
3. Glazing Tape
4. Sealing Tapes
C. SD-07 Certificates
1. Insulating Glass
2. Plastic Glazing
D. SD-08 Manufacturer's Instructions Setting and Sealing Materials
1. Glass Setting
E. SD-11 Closeout Submittals
1. Warranty for Insulated Glass Units
2. Warranty for Polycarbonate Sheet
3. Warranty for Monolithic Reflective Glass
4. Warranty for Monolithic Opacified Spandrel
1.3 SYSTEM DESCRIPTION
Fabricate and install watertight and airtight glazing systems to withstand thermal movement and wind loading without glass breakage, gasket failure, deterioration of glazing accessories, or defects in the work. Glazed panels must comply with the safety standards, in accordance with ANSI Z97.1, and comply with indicated wind/snow loading in accordance with ASTM E1300.
1.4 QUALITY CONTROL
Submit two 8 by 10-inch samples of each of the following: tinted glass, patterned glass, heat-absorbing glass, and insulating glass units. Submit three samples of each other material. Samples of plastic sheets must be minimum 5 by 7 inches.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver products to the site in unopened containers, labeled plainly with manufacturers' names and brands. Store glass and setting materials in safe, enclosed dry locations and do not unpack until needed for installation. Handle and install materials in a manner that will protect them from damage.
08 81 00 – GLAZING 3 March 2022
1.6 ENVIRONMENTAL REQUIREMENTS
Do not start glazing work until the outdoor temperature is above 40 degrees F and rising, unless procedures recommended by the glass manufacturer and approved by the Contracting Officer are made to warm the glass and rabbet surfaces. Provide ventilation to prevent condensation of moisture on glazing work during installation. Do not perform glazing work during damp or rainy weather.
1.7 WARRANTY
A. Warranty for Insulated Glass Units
Warranty insulating glass units against development of material obstruction to vision (such as dust, fogging, or film formation on the inner glass surfaces) caused by failure of the hermetic seal, other than through glass breakage, for a 10-year period following acceptance of the work. Provide new units for any units failing to comply with terms of this warranty within 45 working days after receipt of notice from the Government.
B. Monolithic Opacified Spandrel
Manufacturer must warrant the opacifier film on the spandrel to be free of peeling for a period of five years after Date of Substantial Completion.
Warranty must be signed by manufacturer.
PART 2 PRODUCTS
2.1 GLASS
ASTM C1036, unless specified otherwise. In doors and sidelights, provide safety glazing material conforming to 16
CFR 1201.
A. Clear Glass
For interior glazing (i.e., pass and observation windows), 1/4-inch-thick glass should be used.
Type I, Class 1 (clear), Quality q4 (A). Provide for glazing openings not indicated or specified otherwise. Use double-strength sheet glass or 1/8-inch float glass for openings up to and including 15 square feet, 3/16 inch for glazing openings over 15 square feet but not over 30 square feet, and 1/4 inch for glazing openings over 30 square feet but not over 45 square feet.
B. Annealed Glass
Annealed glass must be Type I transparent flat type, Class 1 - clear, Quality q3 - glazing select, conforming to
ASTM C1036.
C. Heat-Absorbing Glass
Type I, Class 2 (tinted), Quality q3 ¼ inch thick, color to be determined, conforming to ASTM C1036.
D. Laminated Glass
ASTM C1172, Laminated glass fabricated from two nominal 1/8 inch pieces of Type I, Class 1, Quality Q3, flat annealed clear glass conforming to ASTM C1036. Flat glass to be laminated together with a minimum of 0.030 inch thick, clear polyvinyl butyral, conforming to requirements of 16 CFR 1201 and ASTM C1172.
The total thickness of nominally 1/4 inches. Color to be selected from manufacturer’s standard range.
E. Heat-Strengthened Glass
ASTM C1048, Type I, Class 2 (tinted heat absorbing), Quality q3, ¼ inch thick, conforming to ASTM C1036. Color to be selected from manufacturer’s standard range.
F. Spandrel Glass
1. Ceramic-Opacified Spandrel Glass
Ceramic-opacified spandrel glass must be Kind HS heat-strengthened transparent flat type, Condition B, coated with a colored ceramic material on No. 4 surface, Quality q3 - glazing select, ¼ inch thick, conforming to ASTM C1048. Color to be selected from manufacturer’s standard range.
2. Spandrel Glass With Adhered Backing
ASTM C1048, Kind HS or FT, Condition B (ceramic coated), Type I, Quality q5, ¼ inch thick and must pass the fallout resistance test specified in ASTM C1048.
08 81 00 – GLAZING 4 March 2022
2.2 INSULATING GLASS UNITS
A. Manufacturers:
1. Glass: Basis of Design; Guardian Glass, LLC, SunGuard SNX 62/27
B. Insulating Glass Units (IG): Vision glass, double glazed.
1. Applications: Exterior glazing unless otherwise indicated.
2. Two panes of glass separated by a dehydrated airspace, filled with argon gas and hermetically sealed, conforming to ASTM E2190. Submit performance and compliance documentation for each type of insulating glass.
3. Outboard Lite: Fully tempered float glass, 1/4 inch thick minimum
a. Tint : To be determined; to be selected from manufacturer’s standard range
b. Coating: Low-E (passive type), on #2 surface
4. Inboard Lite: Laminated float annealed glass, 9/16 inch thick minimum
a. Tint: Clear
b. Laminated panes shall be adhered to its supporting frame using structural silicone sealant or adhesive glazing tape. The structural silicone sealant bite shall be equal to the larger of 3/8 inch or the thickness of the laminate glass to which it adheres. The minimum thickness of the structural silicone bead shall be 3/16 inch. The glazing tape bite shall be equal to two times the thickness of the laminate glass to which it adheres. The structural silicone bead or glazing tape shall be applied to both sides of single pane laminate glass but need only be applied to the inboard (protected) side of an IGU.
5. Total Thickness: 1 5/16 inch
6. Low -E Coating: pyrolytic or sputtered on second surface.
7. Winter Nighttime U-Factor: 0.29 maximum
8. Visible Light Transmittance (VLT): 62 percent, nominal.
9. Solar Heat Gain Coefficient (SHGC): 0.27, maximum
10. Glazing Method: Dry glazing method, gasket glazing.
11. Tempered glass when required by code.
C. Spandrel Insulating Glass Units (IP): Spandrel glazing
1. Applications: Exterior spandrel glazing unless otherwise indicated.
2. To panes of glass separated by a dehydrated airspace, filled with argon gas hermetically sealed, conforming to ASTEM E2190. Submit performance and compliance documentation to each type of glass.
3. Outboard Lite: Annealed float glass, 1/4 inch thick minimum
a. Tint: To be determined; to be selected from manufacturer’s standard range
b. Coating: Low-E (passive type), on #2 surface
4. Inboard Lite: Laminated Heat-strengthened float glass, 9/16 inch thick minimum
a. Tint: To be determined
b. Opacifier: Ceramic frit, on #4 surface
5. Total Thickness: 1 5/16 inch
6. Thermal Transmittance (U-Value), Winter – Center of Glass: 0.29 maximum
7. Glazing Method: Dry glazing method, gasket glazing.
D. Low Emissivity Coatings
Interior and exterior glass panes for Low-E insulating units must be Type I annealed flat glass, Class 1-clear with anti-reflective low-emissivity coating or heat-strengthened or fully tempered glass complying with ASTM
C1048, Condition C on No. 2 surface (inside surface of exterior pane, Quality q3 - glazing select, conforming to
ASTM C1036. Glass performance must be U value maximum of 0.24 Solar Heat Gain Coefficient (SHGC) maximum of 0.27 Color to be selected from manufacturer’s standard range.
2.3 SETTING AND SEALING MATERIALS
Provide as specified in the GANA Glazing Manual, IGMA TM-3000, IGMA TB-3001, and manufacturer's recommendations, unless specified otherwise herein. Do not use metal sash putty, non-skinning compounds, non-resilient preformed sealers, or impregnated preformed gaskets. Materials exposed to view and unpainted must be gray or neutral color. Sealant testing must be performed by a testing agency qualified according to ASTM C1021.
Submit glass manufacturer's recommendations for setting and sealing materials and for installation of each type of glazing material specified. Include cleaning instructions for plastic sheets.
08 81 00 – GLAZING 5 March 2022
A. Putty and Glazing Compound
Provide glazing compound as recommended by manufacturer for face-glazing metal sash. Putty must be linseed oil type. Do not use putty and glazing compounds with insulating glass or laminated glass.
B. Glazing Compound
Use for face glazing metal sash. Do not use with insulating glass units or laminated glass.
C. Sealants
Provide elastomeric and structural sealants.
1. Elastomeric Sealant
ASTM C920, Type S, Grade NS, Class 12.5, Use G. Use for channel or stop glazing metal sash. Sealants must be chemically compatible with setting blocks, edge blocks, and sealing tapes with sealants used in manufacture of insulating glass units
Color of sealant must be white.
2. Structural Sealant ASTM C1184, Type S.
D. Joint Backer
Joint backer must have a diameter size at least 25 percent larger than joint width; type and material as recommended in writing by glass and sealant manufacturer.
E. Glazing Tapes
1. Back-Bedding Mastic Glazing Tapes
Preformed, butyl-based, 100 percent solids elastomeric tape; nonstaining and nonmigrating in contact with nonporous surfaces; with or without spacer rod as recommended in writing by tape and glass manufacturers for application indicated; and complying with ASTM C1281 and AAMA 800 for products indicated below:
a. AAMA 804.3 tape, where indicated.
b. AAMA 806.3 tape, for glazing applications in which tape is subject to continuous pressure.
c. AAMA 807.3 tape, for glazing applications in which tape is not subject to continuous pressure.
2. Expanded Cellular Glazing Tapes
Closed-cell, PVC foam tapes; factory coated with adhesive on both surfaces; and complying with AAMA
800 for the following types:
a. AAMA 810.1, Type 1, for glazing applications in which tape acts as the primary sealant.
b. AAMA 810.1, Type 2, for glazing applications in which tape is used in combination with a full bead of liquid sealant.
F. Sealing Tapes
Preformed, semisolid, PVC-based material of proper size and compressibility for the particular condition, complying with ASTM D2287. Use only where glazing rabbet is designed for tape and tape is recommended by the glass or sealant manufacturer. Provide spacer shims for use with compressible tapes. Tapes must be chemically compatible with the product being set.
G. Setting Blocks and Edge Blocks
Closed-cell neoprene setting blocks must be dense extruded type conforming to ASTM C509 and ASTM D395, Method B, Shore A durometer between 70 and 90. Edge blocking must be Shore A durometer of 50 (plus or minus 5). Provide silicone setting blocks when blocks are in contact with silicone sealant. Profiles, lengths and locations must be as required and recommended in writing by glass manufacturer. Block color must be black.
H. Glazing Gaskets
Glazing gaskets must be extruded with continuous integral locking projection designed to engage into metal glass holding members to provide a watertight seal during dynamic loading, building movements and thermal movements. Glazing gaskets for a single glazed opening must be continuous one-piece units with factory-fabricated injection-molded corners free of flashing and burrs. Glazing gaskets must be in lengths or units recommended by manufacturer to ensure against pull-back at corners.
Provide glazing gasket profiles as recommended by the manufacturer for the intended application.
1. Fixed Glazing Gaskets
Fixed glazing gaskets must be closed-cell (sponge) smooth extruded compression gaskets of cured elastomeric virgin neoprene compounds conforming to ASTM C509, Type 2, Option 1.
2. Wedge Glazing Gaskets
Wedge glazing gaskets must be high-quality extrusions of cured elastomeric virgin neoprene compounds, ozone resistant, conforming to ASTM C864, Option 1, Shore A durometer between 65 and 75.
3. Aluminum Framing Glazing Gaskets
Glazing gaskets for aluminum framing must be permanent, elastic, non-shrinking, non-migrating, watertight and weathertight.
08 81 00 – GLAZING 6 March 2022
I. Accessories
Provide as required for a complete installation, including glazing points, clips, shims, angles, beads, and spacer strips. Provide noncorroding metal accessories. Provide primer-sealers and cleaners as recommended by the glass and sealant manufacturers. Use ASTM C1087 to determine whether priming and other specific joint preparation techniques are required to obtain rapid, optimum adhesion of glazing sealants to surface.
PART 3 EXECUTION
Any materials that show visual evidence of biological growth due to the presence of moisture must not be installed on the building project.
3.1 PREPARATION
Preparation, unless otherwise specified or approved, must conform to applicable recommendations in the GANA
Glazing Manual, GANA Sealant Manual, IGMA TB-3001, IGMA TM-3000, and manufacturer's recommendations.
Determine the sizes to provide the required edge clearances by measuring the actual opening to receive the glass.
Grind smooth in the shop glass edges that will be exposed in finish work. Leave labels in place until the installation is approved, except remove applied labels on heat-absorbing glass and on insulating glass units as soon as glass is installed. Securely fix movable items or keep in a closed and locked position until glazing compound has thoroughly set.
3.2 GLASS SETTING
Shop glaze or field glaze items to be glazed using glass of the quality and thickness specified or indicated. Glazing, unless otherwise specified or approved, must conform to applicable recommendations in the GANA Glazing
Manual, GANA Sealant Manual, IGMA TB-3001, IGMA TM-3000, and manufacturer's recommendations. Aluminum windows, wood doors, and wood windows may be glazed in conformance with one of the glazing methods described in the standards under which they are produced, except that face puttying with no bedding will not be permitted. Handle and install glazing materials in accordance with manufacturer's instructions. Use beads or stops which are furnished with items to be glazed to secure the glass in place. Verify products are properly installed, connected, and adjusted.
A. Sheet Glass
Cut and set with the visible lines or waves horizontal.
B. Patterned Glass
Set glass with one patterned surface with smooth surface on the weather side. When used for interior partitions, place the patterned surface in same direction in all openings.
C. Insulating Glass Units
Do not grind, nip, or cut edges or corners of units after the units have left the factory. Springing, forcing, or twisting of units during setting will not be permitted. Handle units so as not to strike frames or other objects.
Installation must conform to applicable recommendations of
IGMA TB-3001 and IGMA TM-3000.
D. Installation of Wire Glass
Install glass for fire doors in accordance with installation requirements of NFPA 80.
E. Installation of Heat-Absorbing Glass
Provide glass with clean-cut, factory-fabricated edges. Field cutting will not be permitted.
F. Installation of Laminated Glass
Sashes which are to receive laminated glass must be weeped to the outside to allow water drainage into the channel.
G. Plastic Sheet
Conform to manufacturer's recommendations for edge clearance, type of sealant and tape, and method of installation.
3.3 CLEANING
Clean glass surfaces and remove labels, paint spots, putty, and other defacement as required to prevent staining.
Glass must be clean at the time the work is accepted.
3.4 PROTECTION
Protect glass work immediately after installation. Identify glazed openings with suitable warning tapes, cloth or paper flags, attached with non-staining adhesives. Protect reflective glass with a protective material to eliminate any contamination of the reflective coating. Place protective material far enough away from the coated glass to allow air to circulate to reduce heat buildup and moisture accumulation on the glass. Upon removal, separate
08 81 00 – GLAZING 7 March 2022 protective materials for reuse or recycling. Remove and replace glass units which are broken, chipped, cracked, abraded, or otherwise damaged during construction activities with new units.
3.5 SCHEDULE
Some metric measurements in this section are based on mathematical conversion of inch-pound measurements, and not on metric measurement commonly agreed to by the manufacturers or other parties. The inch-pound and metric measurements are as follows:
PRODUCTS INCH-POUND
Glass 1/8 inch
3/16 inch
7/32 inch
1/4 inch
3/8 inch
Interlayer 0.015 inch
Glazing Channels 1/4 inch
-- END OF SECTION –
08 81 00 – GLAZING 8 March 2022
PAGE INTENTIONALLY LEFT BLANK
.3
.9
.0
.9
.1
.4
.4
.5
.6
.0
.2
.5
.3
.0
.4
.3
.6
.0
.3
.0
150.67
.5
.3
.8
120.00
A
A
A
A
B
C
A
100A
A
110C
S T O R A G E
S T O R A G E
M E C H R O O M
S C U L
LE
R Y
F O O D
P R E P
F O O D
S T O R A G E
S T O R A G E
C L A S S R O O M
C O R R
ID
O R
S T O R A G E
C O
B
M A
IN
T C O N T R O L
C O
B
S U P P L Y
S T A F F
R O O M
O F F
IC
E
R E T E N T
IO
N
O F F
IC
E
O F F
IC
E
F A M
IL
Y
S U P P O R T
C O P
IE
R
M A
IL
F A X
C O
B
T R A
IN
N G
C O
B
R E A D
IN
E S S
V E S T
IB
U L E
T A B L E
C H A
IR
F A C
IL
IT
Y
M A
IN
T
& SERVICE CORRIDOR
R E C R U
IT
IN
G
R E C R U
IT
IN
G
T E L E C O M M
O F F
IC
E
D E E R S
C O
B
T R A
IN
IN
G
A
ID
CORRIDOR
GENERAL FLOOR
PLAN NOTES
A. DIMENSIONS ARE SHOWN FOR
REFERENCE ONLY- CONTRACTORS SHALL
VERIFY ALL DIMENSIONS.
B. PATCH & REPAIR EXISTING WALLS WHERE
ITEMS WERE REMOVED TO MATCH
EXISTING CONDITIONS.
C. THE CONTRACTOR SHALL PROVIDE ALL
NECESSARY PROTECTION OF EXISTING
WORK AND NEWLY ADDED WORK THE
CONTRACTOR SHALL REPAIR AND
RESTORE TO ITS ORIGINAL CONDITION ALL
WORK AND ITEMS DAMAGED AS A RESULT
OF BUILDING OPERATIONS.
D. G.C. TO COORDINATE WITH OWNERS ON
ALL OWNER SUPPLIED/INSTALLED ITEMS.
E. EXISTING CONDITIONS SHOWN ON THE
DRAWINGS ARE ASSUMED. IF CONDITIONS
OTHER THAN THOSE SHOWN EXIST,
IMMEDIATELY NOTIFY ARCHITECT BEFORE
PROCEEDING WITH THE WORK AT THAT
LOCATION; ALTERNATE METHODS OF
CONSTRUCTION MAY NEED TO BE USED.
F. USE APPROPRIATE CONSTRUCTION
METHODS AND EQUIPMENT TO SUPPORT
EXISTING STRUCTURAL FRAMING AND
AVOID OVERSTRESSING THE EXISTING
STRUCTURE AS NEEDED DURING
DEMOLITION AND CONSTRUCTION.
G. PROVIDE PLYWOOD OR OTHER
PROTECTION DURING CONSTRUCTION AND
MOVING MATERIALS.
7048 SF
ASSEMBLY HALL
2 /A-401
A-501
REFERENCE PHOTOS 7, 8,
10-12, ON SHEET A-003
1 /A-401
7.10 8.4
8.4
1 /A-402
7.10
2 /A-402
A-806
A-806
Sim
A-806
Sim
A-501
Sim
7.15
7.15
DEPARTM
EN
T O
F
TH
E M
IL
ITARY
S T A
T E
O F
S O
U T
H D
A K
O T
A
SHEET No:
DATE:
SUBMITTAL:
100%
S O
U T
H D
A K
O T
A D
E P
A R
T M
E N
T O
F T
H E
M
IL
IT
A
R Y
S D
A R
N G
C O
N S T
R U
C T
IO
N
F
A C
IL
IT
Y
M A
N A
G E
M E
N T
O F F
IC
E
W E
S T
M A
IN
S
T R
E E
T
R A
P
ID
C
IT
Y
S D
(6
-6
F A
X
-6
C F
M O
07/07/2026
A-101
R E
P L A
C E
D R
IL
L F
L O
O R
W
IN
D O
W S
A N
D P
A N
E L S
M A
IN
L
E V
E L
F L O
O R
P L A
N
A ir p o rt
R d
M it ch e ll
S
D
PLAN NOTES
7.10 CAP FLASHING, PREFIN METAL
7.15 PREFIN METAL BY ALUM
STOREFRONT PROVIDER
8.4 NEW ALUMINUM STOREFRONT
WINDOW AND FRAME, INSTALL IN
EXISTING OPENING
TRUE
1/16" = 1'-0"
FLOOR PLAN
REVISION SCHEDULE
No. Description Date
1. ADDN #1 07/27/2026
DIGITAL USERS:
CLICK FOR FLOOR PLANHERE
EXISTING ROOF TO REMAIN
EXISTING TERMINATION BAR TO REMAIN
PREFIN BRAKE METAL BY
ALUM STOREFRONT SUPPLIER
SEALANT
BACKER ROD & SEALANT
1' - 0 3/4" ALUMINUM STOREFRONT
TREATED 2X6 WOOD
1' - 0 1/2" FUTURE ROOF INSULATION
EXISTING CMU
PREFIN METAL FLASHING
EXISTING EPDM TO REMAIN
TREATED 2X WOOD
TREATED PLYWOOD
24 GA. PREFIN METAL FLASHING
FILL VOID WITH INSULATION
EXISTING ROOF TO
REMAIN
ALUMINUM STOREFRONT
BACKER ROD & SEALANT
RE-INSTALL SALVAGED
SCUPPER AND DOWNSPOUTS
EXISTING FASCIA AND PREFINISHED
METAL FLASHING/TRIM TO REMAIN
EXISTING STEEL BEAM
REMOVE PAINT FROM SOFFIT, SAND SMOOTH,
PRIME, AND PAINT
FURNISH AND INSTALL NEW TREATED
BLOCKING AS REQUIRED FOR
INSTALLATION OF ALUM STOREFRONT
BACKER ROD & SEALANT
ALUMINUM STOREFRONT
EXISTING MASONRY WALL
EXISTING C4 6X6 @ 20# COLUMN
PREFINISHED METAL BY
STOREFRONT PROVIDER
BACKER ROD & SEALANT
PREFINISHED METAL BY
STOREFRONT PROVIDER
TREATED BLOCKING AS
REQUIRED FOR INSTALLATION
OF ALUM STOREFRONT
ALUM STOREFRONT
REINSTALL SALVAGED
DOWNSPOUT
EXISTING T SHAPED STEEL
DEPARTM
EN
T O
F
TH
E M
IL
ITARY
S T A
T E
O F
S O
U T
H D
A K
O T
A
SHEET No:
DATE:
SUBMITTAL:
100%
S O
U T
H D
A K
O T
A D
E P
A R
T M
E N
T O
F T
H E
M
IL
IT
A
R Y
S D
A R
N G
C O
N S T
R U
C T
IO
N
F
A C
IL
IT
Y
M A
N A
G E
M E
N T
O F F
IC
E
W E
S T
M A
IN
S
T R
E E
T
R A
P
ID
C
IT
Y
S D
(6
-6
F A
X
-6
C F
M O
07/07/2026
A-806
R E
P L A
C E
D R
IL
L F
L O
O R
W
IN
D O
W S
A N
D P
A N
E L S
D E
T A
IL
S
A ir p o rt R d
M it ch e ll
S D
1 1/2" = 1'-0"
ALUM STOREFRONT @ HEAD, TYP
1 1/2" = 1'-0"
ALUM STOREFRONT @ SILL, TYP
1 1/2" = 1'-0"
ALUM STOREFRONT @ JAMB
1 1/2" = 1'-0"
ALUM STOREFRONT @ JAMB
REVISION SCHEDULE
No. Description Date
1. ADDN #1 07/27/2026
009111 - Addendum Number 1