Addendum 1 19359.pdf
PDF 336 KB Posted
- Solicitation number
- RFQ 171 190000000601 2
- Issued by
- Oscoda County, Freeport Village, Michigan
About this file
This is Construction Bid Addendum No. 1 issued by the Department of Technology, Management and Budget (DTMB), State Facilities Administration Design and Construction Division, in coordination with the Department of Natural Resources-Forest Resources Division (DNR-FRD) for the Gaylord Repair Shop Radiant Tube Heat project (File Number 751-19359AGY). The project involves removal and disposal of existing tube heaters from the shop area and installation of new radiant tube heating equipment, including all associated electrical, gas piping, and venting work to comply with applicable Michigan Codes. The scope requires installation of two two-stage natural gas burners rated at 175,000 BTU each with 60-foot tube heat exchangers and shields, and one two-stage natural gas burner at 175,000 BTU with a 70-foot tube heat exchanger and shields, with Superior Radiant Products or approved equivalent equipment. The bid opening date was August 21, 2019, with the addendum issued on August 7, 2019. Bidders were required to acknowledge receipt of this addendum in their bid submission, and failure to do so could result in bid rejection.
The contractor selected for this project is responsible for determining proper equipment heights to accommodate overhead doors, cranes, and lifts within the shop area, obtaining all required permits and inspections through the State of Michigan LARA (Licensing and Regulatory Affairs), and submitting a proposed tube layout with manufacturer specifications as part of the proposal. The addendum attached specifications referenced in the work scope that were not included in the original bid package. Pricing terms, contract duration, and funding sources are not detailed in this addendum document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 75119359AGY 50K Spec (Rev02-19).docx | DOCX document | |
| 751 19359AGY work scope Gaylord Repair Shop Tube Heater Replacement.pdf | ||
| 751 19359AGY DTMB-0415 (Advertisment)(R04-19).doc | DOC document | |
| Pre Bid Sign In 19359.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DTMB-0414 (Rev 12/17)
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
State Facilities Administration Design and Construction Division
CONSTRUCTION BID ADDENDUM NO. 1
This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents. Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.
TO:
ALL BIDDERS
DATE ISSUED
8/7/2019
PROJECT NAME
Gaylord Repair Shop – Radiant Tube Heat
FILE NUMBER
751-19359AGY
PROFESSIONAL
Sharon Conley – DNR-FRD
PROJECT DIRECTOR
Sharon Conley – DNR-FRD
BID OPENING DATE:
8/21/2019
ADDENDUM ITEMS: (attach additional sheets and drawings if required)
Attached are the specifications referenced in the work scope that were not included in the original bid package.
ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.
PROFESSIONAL: Sharon Conley – DNR_FRD DATE: 8/7/2019
APPROVED BY:
PROJECT DIRECTOR: Sharon Conley – DNR-FRD DATE: 8/7/2019 http://www.michigan.gov/SIGMAVSS
Gaylord Repair Shop Tube Heater Replacement
This project consists of removal and proper disposal of existing tube heaters in shop area of the Gaylord Repair Shop and provide all materials, equipment and labor to remove existing and install new tube heaters and shields including all electrical, gas piping and venting as required to meet applicable Michigan Codes.
Proposal to Include cost to remove and dispose of the existing heating equipment in the shop area and install 2 - Two stage natural gas burners at 175,000 btu with 60’ tube heat exchangers with shields.
1 – Two stage natural gas burner at 175,000 btu with 70’ of tube heat exchanger with shields.
Superior Radiant Products or approved equivalent- see attached specifications.
Successful contractor to determine proper heights of all equipment in shop area taking into account overhead doors, cranes and lifts.
Contractor responsible for all permits and inspections through State of Michigan LARA
Proposal to include proposed tube layout and manufactures specifications.
File details come from the government source that posted it. Updated .