About this file

Addendum 1, dated May 2, 2025, is issued by Brevard County Housing and Human Services for the 24-HRAP-28 Rehab/Repair Project located at 1106 Pinedale Rd, Rockledge, FL 32955. The addendum provides two additional scope of work items for the exterior of the property: replacing a damaged gable vent on the right side of the building to ensure code compliance and proper attic ventilation, and repairing damaged and missing vinyl siding to maintain weather protection and code standards. The addendum requires contractors to match existing materials as closely as possible in color, exposure, and texture, with an acknowledgement form for vendors to complete and return.

The images accompanying the addendum visually depict the existing conditions of the property, showing the damaged gable vent area covered with a temporary material and the overall exterior of the building. The top image reveals a white vertical siding structure with a white sheet temporarily covering part of the gable area, while the bottom image shows the broader context of the building with surrounding trees and neighboring structures. These images provide visual documentation of the repair needs outlined in the addendum, supporting the scope of work described in the document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Brevard County Housing and Human Services 24-HRAP-28, 1106 Pinedale Rd, Rockledge, FL 32955

Rehab/Repair Project Addendum 1 May 2, 2025

Location: 2 – Exterior - Spec #2448 VENT – GABLE

Addition to scope of work. Replace damaged gable vent to ensure code compliance.

Existing gable vent on the right side of the building was damaged during storm and is currently covered with a temporary material. Replace with a new, code-compliant vent to ensure proper attic ventilation and to prevent potential moisture damage.

Total Price

Location: 2 – Exterior - Spec #2635 SIDING -- VINYL REPAIR

Addition to scope of work. Replace damaged and missing siding to ensure code compliance and weather protection, including all trim and starter pieces. Match existing as closely as possible in color, exposure and texture.

Total Price

Addendum Acknowledgement

Company Name ____________________________________________________

Authorized Signature ________________________________________________

Printed Name ___________________________________ Date_______________