The document is a detailed architectural building section drawing for a covered parking structure at Jefferson Barracks, located at 4141 May Road in St. Louis, MO. The drawing (Sheet A600) provides technical specifications for a canopy section with precise measurements, including grade levels, clearance heights, and structural details. Key alternates are noted, such as Alternate 3 (deleting PV panel system and adding standing seam metal roof) and Alternate 4 (adding gutters and downspouts). Specific technical specifications include exposed steel to be AESS3, primed and painted, concrete footings to be painted safety yellow, and minimum canopy clearances of 10'-0" on the south side and 12'-0" on the north side. The drawing is marked as a 100% Construction Documents (CD) submittal, dated 07/02/2024, and prepared by BranchPattern with architectural review by Douglas B Loveland, a licensed Missouri architect.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A3 Covered Parking Specifications.pdf | ||
| A3 Revision 1 20240827.pdf | ||
| A3 Covered Parking Drawings 20240702.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S. GRADE - LOW
449'-1"
S. GRADE - HIGH
451'-6"
CLEARANCE
HEIGHT
463'-6"
A
T.O. FOOTING
453'-3"
N. GRADE HIGH
451'-0 101/256"
N. GRADE LOW
448'-4 37/256"
T.O. COLUMN
465'-9"
B.O. FOOTING
443'-3"
(S E
E S
T R
U C
T U
R A
L
(S O
U T
H C
A N
O P
Y M
IN
IM
U M
C L
E A
R A
N C
E
(N O
R T
H C
A N
O P
Y M
IN
IM
U M
C L E
A R
A N
C E
/2
2 1/8"
12"
A600
24'-0"
23'-7 1/2" +/-
NOTE: VERIFY OVERALL
ROOF DIMENSIONS WITH
FINAL SOLAR PANEL
INSTALL DIMENSIONS
ALTERNATE 4: ADD GUTTER AND
DOWNSPOUTS; 6" STYLE "A"
GUTTER, 4" DOWNSPOUT AT
EACH COLUMN, PROVIDE AND
INSTALL BRACKETS AS
REQUIRED, PREFINISHED TO
MATCH STEEL PAINT
ALTERNATE 3: DELETE PV
PANEL SYSTEM AND ADD
STANDING SEAM METAL ROOF;
PROVIDE INSTALLATION SHOP
DRAWINGS
EXPOSED STEEL TO BE AESS3,
PRIMED AND PAINTED, TYP.
ALTERNATE 2: PROVIDE
WATERPROOF DUPLEX
RECEPTACLE AT SECOND AND
FIFTH COLUMNS, TYP.; SEE
ELECTRICAL
PAINT EXPOSED CONCRETE
FOOTINGS SAFETY YELLOW,
TYP.
CLEARANCE
HEIGHT
463'-6"
ALTERNATE 4: ADD GUTTER AND
DOWNSPOUTS; 6" STYLE "A"
GUTTER, 4" DOWNSPOUT AT
EACH COLUMN, PROVIDE AND
INSTALL BRACKETS AS
REQUIRED, PREFINISHED TO
MATCH STEEL PAINT
ALTERNATE 3: DELETE PV
PANEL SYSTEM AND ADD
STANDING SEAM METAL ROOF;
PROVIDE INSTALLATION SHOP
DRAWINGS
SEE STRUCTURAL
PRELIMINARY
DRAWINGS FOR
REVIEW
PURPOSES ONLY,
NOT FOR
CONSTRUCTION
OR
IMPLEMENTATION
www.branchpattern.com
BETTER BUILT ENVIRONMENTS
Phone: 800-200-9160
These drawing and the designs here Illustrated are the sole property of BranchPattern, Inc. and may not be reproduced in whole or in part without express written permission.
Designed By:
Drawn By:
Reviewed By:
Project No:
Date:
Submittal Level:
Sheet Title:
Sheet No.:
1218003
Seal:
Civil Engineering | Surveying | Utilities | Construction Services 7101 College Blvd., Ste. 400 Overland Park, KS 66210 o: (913) 663-1900
P R
O J E
C T
N A
M E
TM
TM
07/02/2024
A600
BUILDING SECTIONS
100% CD
KM
J E
F F
E R
S O
N B
A R
R A
C K
S C
O V
E R
E D
P A
R K
IN
G
B
U
IL
D
IN
G
M
A Y
R O
A D
S T
L
O U
IS
M O
1/2" = 1'-0"1 CANOPY SECTION
1" = 1'-0"3 LOWER ROOF EDGE DETAIL
Description Date
REVISION 1 8/27/24
Seal:
D ou gl as
B L ov el an d
A rc hi te ct M
O A
-2
77/
2/
| Sheets |
| A600 - BUILDING SECTIONS |