A1j - 3740-23-000003 DRAWINGS Solicitation.pdf
PDF 28 MB Posted
- Solicitation number
- GNFR-FC-CAV-24-20593
- Issued by
-
Department of Defense
About this file
This solicitation is for the renovation of an existing Burger King located at Fort Cavazos, Texas to be converted into a Panera Bread with a drive-thru. The project will reconfigure mechanical, electrical and plumbing systems to accommodate Panera's food equipment and finishes will be replaced to meet Panera's branding standards. Interested parties can find additional details and amendments on the Army Air Force Exchange Service's construction solicitation website at https://odin.aafes.com/ConstructionSolicitations/. Proposals must acknowledge any amendments and be submitted through the portal to be considered for this project numbered 3740-23-000003 being undertaken by the Department of Defense.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Room name
101A ROOM NUMBER
101 DOOR NUMBER
A1.1
A1.1
WALL SECTION / SECTION DETAIL
A1.1
ENLARGED DETAIL
INTERIOR ELEVATION
ELEVATION REFERENCE
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET WHERE DRAWN
A WINDOW TAG
DEMOLITION REFERENCE NOTE
REFERENCE NOTE1
TOILET ACCESSORY REFERENCE NOTEA
G3.B.2 WALL TAG
A1.11
EXTERIOR ELEVATION
ELEVATION NUMBER
SHEET WHERE DRAWN
North
NORTH ARROW
? KEYNOTE INDICATION 04A01
000 EQUIPMENT TAG
FINISH TAG
WDXXXXX
CASEWORK/ WOOD ID TAG
XXXX
XXXXXXXX
LIGHTING ID TAG
ARTWORK ID TAG
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
Project Team Index of Drawings Drawing Symbols
Base Location Map
Area Location Map Site Location Map/ Haul Route
CONVERT BK TO PANERA WITH DRIVE-THRU
Ft. Cavazos, Texas
AAFES PN: 3740-23-000003
PANERA STORE 2479
October 23, 2023
ISSUED FOR SOLICITATION
ARCHITECT
MECHANICAL/ ELECTRICAL ENGINEERS
12" = 1'-0"10.23.2023
T-1.00 3740-23-000003
TITLE SHEET / INDEX
OF DRAWINGS
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
SHEET INDEX
SHEET NO. SHEET NAME
GENERAL
T-1.00 TITLE SHEET / INDEX OF DRAWINGS
T-1.01 GENERAL INFORMATION SHEET
T-1.02 REFERENCE FLOOR PLAN AND LIFE SAFETY PLAN
CIVIL
C-1.00 SITE PLAN
C-1.01 SITE DETAILS
DEMOLITION
D-1.01 DEMOLITION FLOOR PLAN
D-1.02 DEMOLITION FLOOR SLAB PLAN
D-6.01 DEMOLITION ELEVATIONS
D-7.01 DEMOLITION REFLECTED CEILING PLAN
ARCHITECTURAL
A-1.01 FLOOR PLAN
A-1.02 FLOOR SLAB & DIMENSION PLANS
A-4.01 EXTERIOR BUILDING ELEVATIONS
A-5.01 ROOF PLAN
A-6.01 INTERIOR ELEVATIONS - FRONT OF HOUSE
A-6.02 INTERIOR ELEVATIONS - BACK OF HOUSE
A-6.03 CASEWORK SECTIONS, SCHEDULES, DETAILS, & 3D VIEWS
A-7.01 REFLECTED CEILING PLAN & CEILING DETAILS
A-9.01 INTERIOR MATERIALS LIST
A-9.02 INTERIOR FINISH PLAN
FS-1.01 EQUIPMENT PLAN
FS-1.02 EQUIPMENT SCHEDULE, NATIONAL ACCOUNTS CONTACTS
MECHANICAL
MD-1.01 DEMOLITION FLOOR PLAN - MECHANICAL
M-1.01 FLOOR PLAN - MECHANICAL
M-2.01 SYMBOLS AND SCHEDULES - MECHANICAL
PLUMBING
PD-1.01 DEMOLITION FLOOR PLAN - PLUMBING
P-1.01 FLOOR PLAN - PLUMBING
P-1.02 FLOOR PLAN - PLUMBING
P-2.01 SYMBOLS AND SCHEDULES - PLUMBING
FIRE PROTECTION
FP-1.00 FLOOR PLANS - FIRE PROTECTION
FA-0.01 SYMBOLS, SCHEDULES AND GENERAL NOTES - FIRE ALARM
FAD-1.01 DEMOLITION FLOOR PLAN - FIRE ALARM
FA-1.01 FLOOR PLAN - FIRE ALARM
ELECTRICAL
E-0.01 SYMBOLS AND SCHEDULES - ELECTRICAL
ED-1.01 DEMOLITION FLOOR PLAN - LIGHTING
ED-2.01 DEMOLITION FLOOR PLAN - POWER
E-1.01 FLOOR PLAN - LIGHTING & SITE PLAN
E-2.01 FLOOR PLAN - POWER
E-3.00 RISER DIAGRAM AND PANEL SCHEDULES - ELECTRICAL
PROJECT SITE PROJECT SITE
BUILDING 33012 - 761 TANK BATTALION AVENUE
FORT CAVAZOS, TX 76544
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
001-022279 T
10/23/2023
2S2S
2H2H
1S1S
1H1H
SSSS
SS
E2SE2S
E2HE2H
E1SE1S
E1HE1H
ESSESS
ESES
WATER COOLER
PAPER TOWEL
DISPENSER
FIRE EXTINGUISHER
CABINET
C .L
. O F
H
AN
D
LE
" M
AX
. T
O
FIRE HOSE
CABINET
C .L
. O F
H
AN
D
LE
" M
AX
. T
O
3'
4"
" M
AX
" M
IN
9" M
IN
DEPTH
17" MIN.
TOE CLEARANCE
6" MAX.
KNEE CLEARANCE
8" MIN.
4'
1/
2"
3'
0"
2'
3/
4"
9 7/8"1' - 7 3/4"
" M
AX
TOWEL
DISPENSING
GENERAL ABBREVIATIONS:
AFF. Above Finish Floor ACC. Accessories ACST. Acoustic AB. Acoustic Board AP. Acoustic Panel AT. Acoustic Tile ADD. Add, Addition or Additional ADDM. Addendum ADJT. Adjacent ADJ. Adjustable AGGR. Aggregate ALT. Alternate APPROX. Approximate AD. Area Drain ARCH. Architectural ASPH. Asphalt AUTO. Automatic BB STOP Basketball Backstop BJ. Bar Joist BSMT. Basement BM. Beam BRG. Bearing BR. Bedroom B/M Bench Mark BITUM. Bituminous BLK. Block BLKG. Blocking BRD. Board BOT. Bottom B/C Bottom of Curb B/F Bottom of Footing B/W Bottom of Wall BRKT. Bracket BLDG. Building CBT. Cabinet CPT. Carpet CI. Case Iron CB. Catch Basin CLG. Ceiling CEM. Cement CTR. Center C/C Center to Center CER. Ceramic CT. Ceramic Tile CLR. Clear CLO. Closet CW. Cold Water COL. Column CPU. Computer
(Central Processing Unit) CONC. Concrete CMU. Concrete Masonry Unit CONF. Conference CONSTR. Construction CONT. Continuous CONTR. Contractor CTL. Control CJ. Control Joint CORR. Corridor CNTR. Counter CS. Countersunk DP. Deep DEPT. Department DET. Detail DIA. Diameter DIM. Dimension DR. Door DO. Door Opening DBL. Double DN. Down DS. Down Spout DWG. Drawing DF. Drink Fountain
EA. Each EW. Each Way ELECT. Electrical EWC. Electrical Water Cooler EL. Elevation ELEV. Elevator ENCL. Enclosure ENGR. Engineer ENTR. Entrance EQ. Equal EXH. Exhaust EXIST Existing EXP. Expansion EJ. Expansion Joint EXT. Exterior F4S. Finish Four Sides FWC. Fabric Wall Covering FOC. Face of Concrete FOF. Face of Finish FOS. Face of Studs FIN. Finish FIN. FL. Finish Floor FG. Finish Grade FE. Fire Extinguisher FEC. Fire Extinguisher Cabinet FHC. Fire Hose Cabinet FH. Fire Hydrant FLR. Floor FD. Floor Drain FT. Foot or Feet FTG. Footing FND. Foundation FURR. Furring FURN. Furnishing GC. General Contractor GL. Glass GR. Grade GRAN. Granular GYM. Gymnasium GYP. Gypsum GYP. BD. Gypsum Board HDW. Hardware HDWD. Hardwood HT. Height HP. High Point HM. Hollow Metal HORZ. Horizontal IN. Inch IEC. In Electrical Contract IMC. In Mechanical Contract IPC. In Plumbing Contract ID. Inside Diameter INSUL. Insulation INT. Interior JAN. Janitor JC. Janitor's Closet JT. Joint JST. Joist LAB. Laboratory LDR. Ladder LAM. Laminate LAV. Lavatory LG. Length LP. Low Point MH. Manhole MFR. Manufacturer MO. Masonry Opening MAX. Maximum MECH. Mechanical MEMBR. Membrane MTL. Metal MEZZ. Mezzanine MLWK. Millwork
MIN. Minimum MISC. Miscellaneous MLDG. Moulding MTD. Mounted MNTG. Mounting NOM. Nominal NIC. Not In Contact NTS. Not To Scale NO. Number OC. On Center OPNG. Opening OPP. Opposite OD. Outside Diameter OF. Outside Face OA. Overall OH. Overhead PR. Pair PC. Piece PLAS. Plastic P-LAM. Plastic Laminate PL. Plate PLWD. Plywood PT. Point PVC. Polyvinyl Chloride QT. Quarry Tile RAD. Radius REINF. Reinforce or Reinforcing REBAR. Reinforcing Bar REQD. Required R. Riser RD. Roof Drain RM. Room RGH. Rough RO. Rough Opening SCH. Schedule SLT. Sealant SHT. Sheet SIM. Similar STC. Sound Transmission Class
Rating Eg45) SYM. Symmetrical TEL. Telephone T.V. Television TEMP. Tempered TRD. Tread THK. Thick, Thickness T & G. Tongue and Groove T/B. Top of Beam T/C. Top of Curb T/CONC. Top of Concrete T/F Top of Footing T/J Top of Joist T/S Top of Steel T/M Top of Masonry T/W Top of Wall TRT. WD. Treated Wood TYP. Typical UL. Underwriter's Label VERT. Vertical VCT. Vinyl Composition Tile VT. Vinyl Tile VWC. Vinyl Wall Covering WC. Water Closet WT. Weight W.W.F. Welded Wire Fabric WID. Width W/ With W/O Without WD. Wood WP. Work Point YH. Yard Hydrant
DEMO LETTER DEFINITIONS
A SITEWORK
B CONCRETE WORK
C MASONRY
D METALS
E WOOD & PLASTICS
F THERMAL & MOISTURE PROTECTION
G DOORS & WINDOWS
H FINISHES
J SPECIALTIES
K EQUIPMENT
L FURNISHINGS
M SPECIAL CONSTRUCTION
N CONVEYING SYSTEMS
O MECHANICAL
P ELECTRICAL
RATED PARTITION LEGEND:
SMOKE TIGHT WALL UP TO FLOOR OR ROOF DECK
ABOVE (SEALED PERIMETER AND PENETRATIONS)
1-HOUR FIRE BARRIER WALL UP TO FLOOR OR ROOF
DECK ABOVE. (FIRE DAMPERS, 45 MIN. LABELED
DOORS AND FRAMES, FIRE CAULK PENETRATIONS)
2-HOUR FIRE BARRIER WALL UP TO FLOOR OR ROOF
DECK ABOVE. (FIRE DAMPERS, 90 MIN. LABELED
DOORS AND FRAMES, FIRE CAULK PENETRATIONS)
SMOKE BARRIER WALL UP TO FLOOR OR ROOF DECK
(1-HOUR CONSTRUCTION WITH 20 MIN. LABELED
DOORS AND SMOKE DAMPERS, SEALED PERIMETER
AND PENETRATIONS)
SMOKE BARRIER 1-HOUR FIRE BARRIER WALL UP TO
FLOOR OR ROOF DECK ABOVE. (FIRE AND SMOKE
DAMPERS, 45 MIN. LABELED DOORS AND FRAMES,
FIRE CAULK PENETRATIONS)
SMOKE BARRIER 2-HOUR FIRE BARRIER WALL UP TO
FLOOR OR ROOF DECK ABOVE. (FIRE AND SMOKE
DAMPERS, 90 MIN. LABELED DOORS AND FRAMES,
FIRE CAULK PENETRATIONS)
THE PREFIX 'E' DENOTES EXISTING WALL RATING.
PARTITION PRIORITY LEGEND
TWO HOUR RATED FIRE AND SMOKE PARTITION PRIORITY 1 HIGHEST
TWO HOUR RATED SHAFTWALL PRIORITY 2
TWO HOUR RATED PARTITION
ONE HOUR SMOKE PARTITION PRIORITY 3
ONE HOUR RATED PARTITION PRIORITY 4
PARTITION TO DECK PRIORITY 5
PARTITION TO 4" MIN. ABOVE CEILING PRIORITY 6 LOWEST
THIS DRAWING IS FOR
GRAPHIC PRESENTATION
ONLY. REFERENCE
PARTITION TYPE FOR
NUMBER OF LAYERS OF
GYP. BD., ETC.
HIGHER PRIORITY
WALLS TO RUN
CONTINUOUS PAST
LOWER PRIORITY WALL
LOWER
PRIORITY
WALL
SEE PLAN DIMENSION
USE 3 5/8" MTL STUDS
USE 6" MTL STUDS
USE 2 1/2" MTL STUDS
USE 1 5/8" MTL STUDS 8" THICKNESS TO FINISH
V3
V2
V1
V V6
V8
20GA CHANNEL RUNNERS ATTACHED
W/ FASTENERS @ 24" O.C. MAX.
FINISHED
FLOOR
CHANNEL SHAPED 20 GA. STEEL
STUDS @ 16 in. O.C. MAX.
5/8" DUROCK BRAND CEMENT BOARD
ATTACHED TO METAL STUDS W/1-1/4"
HOT-DIPPED GALVANIZED SCREWS @
8" O.C.
5/8" FIRE TREATED PLYWOOD
ATTACHED W/ 1" TYPE 'S'
SCREWS @ 8" O.C. ALONG
EDGES, @ 12" O.C. IN THE
FIELD OF THE BOARD. JOINTS
ORIENTED VERTICALLY AND
STAGGERED ON OPPOSITE SIDES
OF ASSEMBLY.
FRONT OF HOUSE
BACK
OF HOUSE
IF TILE FINISH: 5/8" DUROCK
BRAND CEMENT BOARD
IF WOOD FINISH: 5/8" PLYWOOD
TO REPLACE CEMENT BOARD.
SCHEDULED
CEILING
20GA CHANNEL RUNNERS ATTACHED
W/ FASTENERS @ 24" O.C. MAX.
3-5/8" KICKERS ATTACHED
@ 4' O.C. MAX. ALTERNATE
DIRECTION TO STRUCTURE ABOVE
PL
AN
2' -0
7'
-0
3"
GENERAL NOTES
A.
B.
C.
D.
E.
F.
G.
H.
I.
ALL PARTITIONS EXTEND TO ROOF OR FLOOR STRUCTURE ABOVE UNLESS
NOTED OTHERWISE.
REFER TO LIFE SAFETY PLAN FOR FURTHER INFORMATION REGARDING FIRE/
SMOKE RATINGS AND LOCATIONS.
REFER TO EXTERIOR WALL SECTIONS AND DETAILS FOR EXTERIOR WALL
MATERIALS AND FINISHES.
PROVIDE 20 GAUGE METAL STUDS, UNLESS NOTED OTHERWISE OR REQUIRED
BY METAL STUD GAUGE SELECTION CHART.
PROVIDE (2) 20 GAUGE METAL STUDS AT ALL WINDOW AND DOOR JAMBS.
ALL FIRE-RATED PARTITIONS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH
APPROPRIATE U.L. ASSEMBLY.
REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF SOUND
ATTENUATION BLANKETS.
PARTITIONS NOT REQUIRED TO EXTEND TO FLOOR OR ROOF STRUCTURE
ABOVE SHALL BE BRACED BY ATTACHING ALTERNATING DIAGONAL STUDS 48"
O.C. (MAX.) FROM TOP OF PARTITION TO STRUCTURE ABOVE.
FIRE RATED WALLS TO RECEIVE ELECTRICAL OUTLET BOXES SHALL CONFORM
TO THE FOLLOWING GUIDELINES. METALLIC OUTLET BOXES SHALL BE UTILIZED
IN WALLS AND PARTITIONS WITH A TWO HOUR OR LESS CLASSIFICATION. THE
SURFACE AREA OF INDIVIDUAL BOXES SHALL NOT EXCEED 16 SQUARE INCHES.
THE AGGREGATE SURFACE AREA OF BOXES SHALL NOT EXCEED 100 SQUARE
INCHES IN ANY 100 SQUARE FEET. BOXES LOCATED ON OPPOSITE SIDES OF
RATED WALL OR PARTITIONS SHALL BE SEPARATED BY A MINIMUM HORIZONTAL
DISTANCE OF 24 INCHES.
INTERIOR PARTITION METAL
STUD GAUGE SELECTION CHART
16" O.C. STUD SPACING WITH ALLOWABLE DEFLECTION CRITERIA OF L\360
STUD
DEPTH
MAXIMUM VERTICAL
UNBRACED SPAN IN FEET
(1 LAYER GYPSUM
BOARD EACH SIDE)
MAXIMUM VERTICAL
UNBRACED SPAN IN FEET
(2 LAYER GYPSUM BOARD
EACH SIDE)
STUD
GAUGE
1-5/8" 8'-3" 9'-0" 25 2-1/2" 10'-9" 11'-9" 25 2-1/2" 11'-6" 12'-3" 22 2-1/2" 12'-0" 14'-0" 20 3-5/8" 14'-0" 14'-9" 25 3-5/8" 15'-0" 15'-9" 22 3-5/8" 15'-7" 17'-8" 20
4" 15'-0" 15'-9" 25 4" 16'-3" 16'-9" 22 4" 16'-10" 16'-11" 20 6" 20'-0" 20'-0" 25 6" 22'-0" 22'-9" 22 6" 22'-10" 24'-11" 20
SEE PLAN DIMENSION
USE 3 5/8" MTL STUDS
USE 6" MTL STUDS
USE 2 1/2" MTL STUDS
USE 1 5/8" MTL STUDS 8" THICKNESS TO FINISH
S3
S2
S1
S S6
S8
20GA CHANNEL RUNNERS ATTACHED
W/ FASTENERS @ 24" O.C. MAX.
FINISHED
FLOOR
CHANNEL SHAPED 20 GA. STEEL
STUDS @ 16 in. O.C. MAX.
5/8" DUROCK BRAND CEMENT BOARD
ATTACHED TO METAL STUDS W/1-1/4"
HOT-DIPPED GALVANIZED SCREWS @
8" O.C.
5/8" FIRE TREATED PLYWOOD
ATTACHED W/ 1" TYPE 'S'
SCREWS @ 8" O.C. ALONG
EDGES, @ 12" O.C. IN THE
FIELD OF THE BOARD. JOINTS
ORIENTED VERTICALLY AND
STAGGERED ON OPPOSITE SIDES
OF ASSEMBLY.
SCHEDULED
CEILING
20GA CHANNEL RUNNERS ATTACHED
W/ FASTENERS @ 24" O.C. MAX.
3-5/8" KICKERS ATTACHED
@ 4' O.C. MAX. ALTERNATE
DIRECTION TO STRUCTURE ABOVE
PL
AN
2' -0
7'
-0
3"
FRP ON BOTH SIDES
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
As indicated10.23.2023
T-1.01 3740-23-000003
GENERAL
INFORMATION SHEET
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
3/8" = 1'-0"
STANDARD MOUNTING HEIGHTS
DESIGN CRITERIA
UNIFIED FACILITIES CRITERIA (UFC)1-200-01
DOD BUILDING COD, IBC 2021 & 2020
BUILDING TYPE
OCCUPANCY
FIRE PROTECTION
ALLOWABLE SOIL
BEARING PRESSURE
LIVE LOAD ROOF
GROUND SNOW LOAD
WIND LOAD BASIC WIND SPEED = 112 MPH
EXPOSURE = C
RISK FACTOR = II
SEISMIC LOAD
TYPE II-B
A-2, B, M, S
FULLY SPRINKLERED
1,500 PSF
20 PSF
10 PSF
SEISMIC DESIGN CATEGORY = A
SITE CLASS = D
REGULATORY REQUIREMENTS
APPLICABLE CRITERIA:
INSTALLATION DESIGN GUIDES (IDG):
DEPARTMENT OF PUBLIC WORKSDPW
ARCHITECTURAL SERVICES REQUIREMENTS FOR
PREPERATION OF CONTRACT DOCUMENTS
ENERGY POLICY ACT OF 2005
WATER CONSERVVATION REQUIREMENT OF THE FEDERAL
ENERGY POLICY ACT
1 1/2" = 1'-0"
PARTITION TYPE V
1 1/2" = 1'-0"
PARTITION TYPE S
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
NOTES
ACCESSIBLE PATH OF TRAVEL SLOPES NOT TO
EXCEED RUNNING SLOPE OF 1:20 (5%) MAX, AND
CROSS SLOPE OF 1:50 (2%) MAX
ACCESSIBLE PARKING SPACES AND AISLES
SHALL BE LEVEL WITH SURFACE SLOPES AND
NOT EXCEEDING 1:50 (2%) IN ALL DIRECTIONS.
TOTAL TRAVEL DISTANCE 80'-7"
TO
TA
L
TR
A V E L D
IS
TA
N C E 9' -6
TO
TA
L
TR
A V E L D
IS
TA
N C E 4' -0
FE
FE
FE
FE
FE
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
1/8" = 1'-0"10.23.2023
T-1.02 3740-23-000003
REFERENCE FLOOR
PLAN AND LIFE SAFETY
PLAN
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
North
1/8" = 1'-0"
FIRST FLOOR REFERENCE AND LIFE SAFETY PLAN
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
SAWCUT AND REMOVE ASPHALT AS REQUIRED TO
INSTALL NEW CONCRETE PAD.
SAWCUT AND REMOVE CONCRETE AND DETECTOR
LOOP AS REQUIRED TO INSTALL NEW DETECTOR
LOOP.
REMOVE MENU CANOPY AND ORDER STATION,
REMOVE FOOTING AND REFER TO ELECTRICAL
DRAWINGS FOR REMOVAL OF ELECTRICAL
CONNECTIONS.
REMOVE MENU BOARD, REMOVE FOOTING AND
REFER TO ELECTRICAL DRAWINGS FOR REMOVAL
OF ELECTRICAL CONNECTIONS.
REMOVE INTERNALLY LIT DIRECTIONAL SIGN, CAP
ELECTRICAL CONNECTION REFER TO ELECTRICAL
DRAWINGS.
REMOVE CLEARANCE BAR AND FOOTING.
REMOVE TENANT DECAL FOR BURGER KING - SEE
REMOVE BURGER KING BUILDING MOUNTED
INTERNALLY LIT SIGNAGE, MAINTAIN ELECTRICAL
CONNECTION FOR REUSE.
REMOVE BUILDING CANOPY. PROVIDE SEALANT
MATCHED TO BUILDING EXTERIOR TO FILL HOLES IN
BRICK.
REMOVE BOLLARD AND PATCH CONCRETE.
SITE DEMOLITION PLAN
REFERENCE NOTES::
/4 C-1.00
VERIFY WITH MUNICIPAL OR UTILITY AUTHORITIES,
LOCATIONS OF EXISTING UTILITIES ABOVE AND BELOW
GRADE. CONTRACTOR IS RESPONSIBLE FOR
PROTECTING AND MAINTAINING UTILITIES TO REMAIN.
SITE PLAN REFERENCE NOTES:
1 NEW MENU BOARD AND FOOTING IN NEW LOCATION,
SEE ELECTRICAL AND DATA DRAWINGS FOR
CONNECTIONS AND SITE SIGNAGE SCHEDULE FOR
TYPE.
NEW PRE ORDER BOARD AND FOOTING IN NEW
LOCATION, SEE ELECTRICAL AND DATA DRAWINGS
FOR CONNECTIONS AND SITE SIGNAGE SCHEDULE
FOR TYPE.
NEW CANOPY AND FOOTING IN NEW LOCATION, SEE
ELECTRICAL DRAWINGS FOR CONNECTIONS AND SITE
SIGNAGE SCHEDULE FOR TYPE.
NEW DRIVE THRU SIGNAGE NON ILLUMINATED AND
FOOTING, REFER TO SITE SIGNAGE SCHEDULE FOR
TYPE.
NEW WALL MOUNTED LIT SIGNAGE, SEE ELECTRICAL
DRAWINGS FOR CONNECTIONS AND SITE SIGNAGE
SCHEDULE FOR TYPE.
EXISTING BOLLARD TO REMAIN
VINYL INSERT PROVIDED BY OWNER, ART PROVIDED
BY PANERA, INSTALLED BY CONTRACTOR.
NEW DETECTOR LOOP, INFILL WITH NEW CONCRETE
AT DETECTOR LOOP. PROVIDE NO. 5 GREASED
DOWELS AT JUNCTURE OF NEW AND EXISTING
CONCRETE. PROVIDE NEW CONCRETE OF THICKNESS
& REINFORCING TO MATCH EXISTING.
NEW BOLLARD AND FOOTING.
NEW CONCRETE PAD, REMOVE ASPHALT, INFILL WITH
NEW CONCRETE.
NEW CLEARANCE BAR.
EXISTING FENCE TO REMAIN
EXISTING UTILITES AND GREASE TRAPS TO REMAIN
NEW CONCRETE SIDEWALK. 5' WIDE X 4" THICK WITH 8"
TURNDOWN ON 4" STONE.
NEW CONCRETE PAD FOR COOLER FREEZER.
NEW COOLER FREEZER BY OWNER.
NEW FENCE. INTEGRATE INTO EXISTING.
CONDENSER UNIT PADS. COORDINATE WITH TAFCO.
A.
B.
C.
D.
E.
F.
ALL WORK SHALL COMPLY WITH THE REGULATION AND
ORDINANCES OF FORT CAVAZOS, AND ANY OTHER
APPLICABLE CODES.
THE GENERAL CONTRACTOR (G.C.) SHALL CONTACT
LOCAL UTILITIES TO VERIFY ALL SIZES, LOCATIONS, AND
CONNECTION POINTS FOR ALL UTILITIES AFFECTED.
ANY CONNECTIONS, DISCONNECTIONS, AND
INSTALLATIONS TO LOCAL UTILITIES SHALL BE MADE IN
ACCORDANCE WITH APPLICABLE CODES.
EXTERIOR BUILDING SIGN FURNISHED AND INSTALLED
BY OWNER'S SIGN VENDOR, G.C. TO PROVIDE POWER.
G.C. TO VERIFY EXISTING SITE CONDITIONS PRIOR TO
BID. ALSO PROVIDE CONTINUOUS CURB CUTS AND
SMOOTH PAVEMENT & CURB TRANSITIONS BETWEEN
NEW AND EXISTING CONDITIONS AS REQUIRED FOR
SITE WORK AS REQUIRED.
G.C. SHALL PROVIDE AND INSTALL ELECTRICAL
CONDUIT AND STRUCTURAL FOOTINGS FOR ALL NEW
SITE DRIVE-THRU SIGNAGE (TYPICAL).
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
NOTE: LANDLORD TO PROVIDE THE FOLLOWING PER
SIGNAGE SHOP DRAWINGS AND SHEET C-1.00
MENU CANOPY: FOUNDATION READY TO RECEIVE
MENU CANOPY STEEL POSTS, CONCRETE PAD, DATA
AND POWER CONDUIT BACK TO BUILDING
CLEARANCE BAR: FOUNDATION READY TO RECEIVE
CLEARANCE BAR STEEL POST.
MENU SIGN: FOUNDATION READY TO RECEIVE MENU
BOARD STEEL POST, CONDUITS STUBBED & CAPPED AT
MENU BOARD AND DRIVE-THRU DIRECTIONAL SIGNAGE
AND BACK TO BUILDING.
PREVIEW MENU SIGN: FOUNDATION, CONDUITS
STUBBED UP AND CAPPED, PULL WIRES
DIRECTIONAL DRIVE THRU SIGNAGE: FOOTING,
FOUNDATIONS AND SIGNAGE, AND CONDUITS STUBBED
UP AND CAPPED TO BUILDING
DIRECTIONAL & THANK YOU SIGNAGE: FOOTING,
FOUNDATION AND SIGNAGE.
DRIVE-THRU WINDOW DETECTOR LOOP IN CONCRETE
PAD WITH ALL ASSOCIATED CONCRETE SLAB AND
CURBING.
DRIVE THRU SIGNAGE NOTES
A-4.01
A-4.01
A-4.01 3
SW210.B1
SW401.A1
SW403.A1
SW403.A1
SW403.A1
SW403.A1
SW403.A1
SW403.A1SW409.A1
SW408.A1
DT003.A1
DT005.A1
DT001.A1
DT004.A1
WIF
C-1.01
16 FS-1.01
A-6.0110
SLOPE @ 1:12 MAX
SLOPE @ 1:12 MAX
F.F.E.
ASSUMED
100'-0"
F.F.E.
99"-7"
C O
N C
. P
AD
8'
0"
W /8
" M
IN
TU
R N
D O
W N
SLOPE @ 1:20 MAX
1:10 SLOPE
EACH WAY
GRADE AS REQUIRED
TO MEET SITE
CONDITIONS AND
PROVIDE POSITIVE
DRAINAGE IN ALL
AREAS OF NEW
WORK.
SW210.E1
OWNER TO
CONFRIM
LOCATION OF
SIGN
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
As indicated10.23.2023
C-1.00 3740-23-000003
SITE PLAN
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
North North
SITE SIGNAGE SCHEDULE
ID TAG QTY DESCRIPTION SIZE
MOUNTING
INSTRUCTIONS DETAIL/REF. COMMENTS
DT001.A1 1 DRIVE THRU MENU CANOPY 6'-6" X 7'-8" REFER TO SHOP
DRAWINGS
6/C-1.01 OF/CI
DT003.A1 1 "DRIVE THRU" HEIGHT CLEARANCE BAR 9'6"H x 6'9"L REFER TO SHOP
DRAWINGS
OF/CI
DT004.A1 1 MENU SIGN 7'-4 3/8"W X 9 1/4"D X 57"H REFER TO SHOP
DRAWINGS
6/C-1.01 OF/CI
DT005.A1 1 PREVIEW MENU SIGN 56 3/8"W X 8 3/4"D X 36"H REFER TO SHOP
DRAWINGS
4/C-1.01 OF/CI
SW210.B1 1 TALL "DRIVE-THRU" DIRECTIONAL SIGN, TURN 21.875"W x 4"D x 41.375"H;
39.375"H SIGN FACE
REFER TO SHOP
DRAWINGS
5/C-1.01 OF/CI
SW210.E1 1 TALL "EXIT ONLY" & "THANK YOU" SIGN 21.875"W x 4"D x 41.375"H;
39.375"H SIGN FACE
REFER TO SHOP
DRAWINGS
5/C-1.01
SW401.A1 1 PAVEMENT SIGN: "DRIVE THRU" W/ ARROW; FULL COLOR APPROX. 8'W REFER TO SHOP
DRAWINGS
OF/CI
SW403.A1 6 PAVEMENT SIGN: ARROW; LIGHT GREEN APPROX. 3'0" W REFER TO SHOP
DRAWINGS
OF/CI
SW408.A1 1 PAVEMENT SIGN: 'DO NOT ENTER' APPROX. 4'10"W REFER TO SHOP
DRAWINGS
OF/CI
SW409.A1 1 PAVEMENT SIGN: 'STOP' WITH HORIZONATAL BAR APPROX. 8'0"W REFER TO SHOP
DRAWINGS
OF/CI
1/16" = 1'-0"
SITE PLAN
1/16" = 1'-0"
SITE DEMOLITION PLAN
1" = 1'-0"
EXISTING BUILDING SIGN
3/C-1.01
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
18"
MAINTAIN 3' OF CLEARANCE ON ALL SIDES FROM REBAR,
WIRESCREEN, REINFORCING BARS, ELECTRICAL CABLE
AND METAL OBJECTS
SPEAKER POST
DATA CONDUIT FROM
INSIDE BUILDING
STUB DETECTOR LOOP
CONDUIT @ SPEAKER POST.
SEE ELECTRICAL SITE PLAN
FOR ADDITIONAL
INFORMATION
POWER CONDUIT FROM
INSIDE BUILDING
DETECTOR LOOP PLAN DETAIL
A - DETECTOR LOOP SECTION @ MENU BOARD
NOTE: REFERENCE ELECTRICAL DRAWINGS & SIGNAGE SHOP
DRAWINGS FOR DETECTOR LOOP INFORMATION & INSTALLATION
INSTRUCTIONS
CURB
CENTERLINE TO ALIGN
WITH CENTERLINE OF
SPEAKER POST/DRIVE
THRU WINDOW
LOOP SUPPORTS
PAVEMENT PER PLAN
VEHICLE DETECTOR
LOOP
8" 6"2"
1/2" PVC TUBING
COUPLING FOR 1/2" PVC TUBING
COORDINATE ELECTRICAL
CONDUIT W/ ELECTRICAL
DWGS.
CONCRETE
BASE FOOTING W/ (4) 3/4"
(ASTM-36) ANCHOR BOLTS
18" MIN EMBEDMENT
24" DIA.
CONCRETE
FOOTING
(4) 1/2" HOLES
12" SQ. STEEL
BASE PLATE BY
SIGN VENDOR
CANOPY ABOVE
A R C H
IT
E C T
TO
C O N
FI
R M D E P
TH
R E
IN
FO
R C E M E N T P E R L O C A L C O D E S
1 1/2" 9"
9"
1/ 2"
12" X 12" X 3/4" THICK
STEEL BASE PLATE W/
CONT. PASS-THRU WELD
TO STEEL SQ. TUBE
3/4" THICK HIGH STRENGTH
NON-SHRINK, NON-
STAINING GROUT. TYP.
ALIGN TOP OF
FOOTING WITH TOP
OF CURB
ALUMINUM
ESCUTCHEON COVER BY
SIGN VENDOR
2' - 0"
5'
0" 4"
E
XP
O
SE
D
SECTION
PLAN
NOTE: REFERENCE MANUFACTURER'S SHOP DRAWINGS PRIOR
TO FORMING/POURING BASES TO COORDINATE BOLT
PLACEMENT.
8" X 14" X 3/4" THICK STEEL
BASE PLATE W/ CONT. PASS-
THRU WELD TO STEEL PIPE
GROUT BASE
CONCRETE
BASE FOOTING W/ (4) 3/4"
(ASTM-36) ANCHOR
BOLTS 18" MIN
EMBEDMENT
3/4" THICK HIGH STRENGTH
NON-SHRINK, NON-
STAINING GROUT. TYP.
ALIGN TOP OF
FOOTING WITH TOP
OF CURB
PLAN
8" X 14" X 3/4" THICK
STEEL BASE PLATE
BY SIGN VENDOR
(4) 1/2" HOLES
18" DIA. CONCRETE
FOOTING
CLEARANCE BAR
ABOVE
A R C H
IT
E C T
TO
C O N
FI
R M D E P
IN
FO
R C E M E N T P E R L O C A L C O D E S
SECTION
ALUMINUM
ESCUTCHEON
COVER BY SIGN VENDOR
4'
0"
1' - 6"
4" E
XP
O
SE
D
6" 1"
NOTE: REFERENCE MANUFACTURER'S SHOP DRAWINGS PRIOR
TO FORMING/POURING BASES TO COORDINATE BOLT
PLACEMENT.
2" 10"
PREVIEW MENU BOARD
SIGN BY SIGN
VENDOR
SECTION
2' - 6"
4'
0" 4"
E
XP
O
SE
D
CONCRETE
BASE FOOTING W/
(4) 3/4" (ASTM-36)
ANCHOR BOLTS 18"
MIN EMBEDMENT
NOTE: REFERENCE MANUFACTURER'S SHOP DRAWINGS PRIOR
TO FORMING/POURING BASES TO COORDINATE BOLT
PLACEMENT.
A R C H
IT
E C T
TO
C O N
FI
R M D E P
IN
FO
R C E M E N T P E R L O C A L C O D E S
(4) 1/2" HOLES. 8" O.C.
30" DIA. CONCRETE
FOOTING
12" X 22" X 3/4" THICK
STEEL BASE PLATE
BY SIGN VENDOR8"
8"
2" X 3" X 1/4" THICK
ALUMINUM TUBE
SUPPORT BY SIGN
VENDOR
4" DIA. HOLE FOR
ELECTRIC FEED
COORDINATE
ELECTRICAL CONDUIT
W/ ELECTRICAL DWGS.
12" X 22" X 3/4" THICK
STEEL BASE PLATE W/
CONT. PASS-THRU WELD
TO STEEL PIPE GROUT
BASE
3/4" THICK HIGH STRENGTH
NON-SHRINK, NON-
STAINING GROUT. TYP.
ALIGN TOP OF FOOTING
WITH TOP OF CURB
ALUMINUM
ESCUTCHEON COVER
BY SIGN VENDOR
DIRECT BURIAL ON
FREE-FORMED
CONCRETE FOOTING
BLACK ALUM. TUBE
POST
DRIVE-THRU
DIRECTIONAL SIGN.
STYLE VARIES; SEE
PLAN.
FORM TOP OF FOOTING
6" BELOW GRADE TO
ALLOW LANDSCAPING TO
COVER
VA
R
IE
S
VA
R
IE
S
6"
[4
NOTE: REFERENCE MANUFACTURER'S SHOP DRAWINGS PRIOR
TO FORMING/POURING BASES TO COORDINATE BOLT
PLACEMENT.
PAVEMENT MARKINGS
SITE SIGNAGE
SW201.A1 SW210.B1 SW201.A1SW201.A1
CONFIRM
ARROW
DIRECTIONS
SW401.A1 SW403.A1 SW406.A1 SW408.A1 SW409.A1
MENU BOARD
SIGN BY SIGN
VENDORMENU
BOARD
SIGN BY
SIGN
VENDOR
6" STEEL SQ. TUBE PAINTED
12" SQ. STEEL
BASE PLATE BY SIGN
VENDOR
ELEVATION SECTION
4'
0" 2"
3' - 6"
CONCRETE
BASE FOOTING W/ (8) 3/4"
(ASTM-36) ANCHOR BOLTS
18" MIN EMBEDMENT
CANOPY TOP
PAINTED TO
MATCH PANTONE
2307 C GREEN
SATINE FINISH
CANOPY TOP
PAINTED TO
MATCH PANTONE
2307 C GREEN
SATINE FINISH
4'
0" 2"
NOTE: REFERENCE MANUFACTURER'S SHOP DRAWINGS PRIOR
TO FORMING/POURING BASES TO COORDINATE BOLT
PLACEMENT.
3' - 6"
9"
9"
PLAN
8"
8"
12" X 22" X 3/4" THICK
STEEL BASE PLATE
BY SIGN VENDOR
A R C H
IT
E C T
TO
C O N
FI
R M D E P
IN
FO
R C E M E N T P E R L O C A L C O D E S
A R C H
IT
E C T
TO
C O N
FI
R M D E P
IN
FO
R C E M E N T P E R L O C A L C O D E
SCOORDINATE
ELECTRICAL CONDUIT
W/ ELECTRICAL DWGS.
GROUT SOLID UNDER
BASE PLATES - TYPICAL
SMOOTH
CROWN ON
TOP, TYP.
4" DIA CONCRETE FILLED
BOLLARD W/ STANDARD
STEEL PIPE. COLOR TO
MATCH PANERA P165
1/2" EXPANSION JOINT
18" DIA.
CONCRETE
FOOTING
CONCRETE CURB &
SLAB AT DRIVE THRU
3"
18" DIA.
3' 0"
3' 0"
SIGN PROVIDED BY
PANERA VENDOR,
INSTALLED BY G.C.
1.66" O.D. 14 GAUGE SIGN
POST HI-DENSITY
POLYETHYLENE
THERMOPLASTIC SILVER
FINISH, 1.90" O.D. 1/8"
NOMINAL WALL THICKNESS
W/ ULTRA-VIOLET AND
ANTI-STATIC ADDITIVE
PLASTIC CAP STANDARD
3/8" HOLES
1' - 0"
1' 4"
" M
IN
SMOOTH
CROWN ON
TOP, TYP.
1/2" EXPANSION JOINT
18" DIA.
CONCRETE
FOOTING
CONCRETE CURB &
SLAB AT DRIVE THRU
.3 '-0
3" 3' 0"
18" DIA
4" DIA CONCRETE FILLED
BOLLARD W/ STANDARD STEEL
PIPE. COLOR TO MATCH P285
(PAINT SAFETY YELLOW AT
DRIVE THRU)
1" WHITE REFLECTIVE
TAPE. PROVIDED AND
INSTALLED BY G.C.
1" 4"
FIRST FLOOR
0"
1/2" EXPANSION JOINT
6" MIN. COMPACTED
GRANULAR BASE
6" REINF. CONCRETE
COOLER/FREEZER SLAB
W/8" FROST WALLS
5"
M
IN
3'
0"
6X6 W2.9XW2.9 WWF
WALK-IN
COOLER/FREEZER (EF/EI)
10"
#5'S @ 12" o.c.
VERT ALL
SIDES
#4 BENT 90'S
(24"HX30"V) ON 16"
CTRS.
SIM BOTH SIDES
TOOLED EDGE +/- 11"
FIELD VERIFY EXISTING
CONCRETE PAD
DIMENSION
NEW PAD TO EXTEND
TO EXISTING
CONCRETE PAD
2" RIGID INSULATION
4"
BEYOND -
CONCRETE TURN
DOWN ALL SIDES
2' - 0"
MIN.
5' - 0"
FENCE LINE
MAX SLOPE OF 1':3'
UNTIL REACHING
EXISTING GRADE
GRADE
SLOPE 1":1'
EXTEND FOOTING
MINIMUM 3' OR UNTIL
ACHIEVING
ACCEPTABLE BEARING
EXISTING COOLER
FLOOR SLAB
INTERIOR RAMP
ANTI-SWEAT
HEATER
SNAP-IN DOOR
SWEEP
TAFCO DOOR
S/S SILL PLATE
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
As indicated10.23.2023
C-1.01 3740-23-000003
SITE DETAILS
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
3/4" = 1'-0"
SECTION DETAILS @ DETECTOR LOOP IN CONCRETE PAD
3/4" = 1'-0"
FOUNDATION DETAIL @ CANOPY
3/4" = 1'-0"
FOUND. DTL @ CLEARANCE BAR
3/4" = 1'-0"
FOUND. DTL @ MENU BOARD
3/4" = 1'-0"
DIRECTIONAL SIGN FOUND. DTL
1/4" = 1'-0"
SITE SIGNAGE
3/4" = 1'-0"
DIGITAL MENU BOARD & CANOPY FOUNDATION DETAILS
3/4" = 1'-0"
BOLLARD DETAIL @ SIGNAGE
3/4" = 1'-0"
BOLLARD DETAIL @ D.T. WINDOW
3/8" = 1'-0"
COOLER SLAB
1/2" = 1'-0"
TAFCO FLOOR SILL
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
DEMOLITION NOTES:
2E1
2E2 DEMOLISH QUEUE LINE RAILS AND PATCH/PREPARE
FLOOR FOR NEW FINISH.
2E3 DEMOLISH PLASTIC LAMINATE BASE CABINETS,
COUNTERTOPS, & SHELVING.
DISCONNECT ALL HARDWIRED & PIPED FOOD SERVICE
EQUIPMENT & DELIVER TO EXCHANGE DESIGNATED ON-SITE
STORAGE. SEE PLUMBING & ELECTRICAL DEMO SHEETS FOR
DEMOLITION OF SERVICES.
2K2
MAINTAIN INSULATED FREEZER FLOOR, WALL, & ROOF PANELS,
DOOR & RELATED HARDWARE. PROTECT UNIT DURING
DEMOLITION AND CONSTRUCTION. REPAIR OR REPLACE ANY
DAMAGE AT SUBSTANTIAL COMPLETION BACK TO EXISTING
CONDITION AT START OF CONSTRUCTION.
2K3
OWNER TO REMOVE EXISTING FURNITURE.2L1
SEE "PD" SHEETS FOR DEMOLITION OF EXISTING SINK AND
RELATED PIPING.
2O1
SEE PD SHEETS FOR DEMOLITION OF WATER FILTER AND
RELATED PIPING.
2O2
SEE "ED" SHEETS FOR DEMOLITION OF EXISTING J-BOXES,
CONDUIT & WIRING WHERE APPLICABLE.
2P2
SEE "ED" SHEETS FOR DEMOLITION OF EXISTING POWER PANEL,
CONDUIT & WIRING.
2P3
DEMOLISH WALL SHELVES & STANDARDS.
2E4 DEMOLISH SOLID SURFACE COUNTERTOP.
OWNER TO RELOCATE EXISTING TRASH UNITS AND LOOSE
FURNITURE.
2L2
MAINTAIN ELECTRICAL PANELS, PROTECT FROM DAMAGE
DURING CONSTRUCTION .
2P1
SEE PD SHEETS FOR DEMOLITION OF ANSUL SYSTEM.2M1
DEMOLISH INTERIOR WOOD DOOR, H.M. FRAME, HARDWARE &
RELATED CONSTRUCTION.
2G1
DEMOLISH LIGHT GAUGE METAL STUD FRAMED GYPSUM
BOARD PARTITION & RELATED FINISHES INCLUDING GLAZED
WALL TILE AND OR WOOD WALL PANELS
2H1
CUT & DEMOLISH DESIGNATED PORTION OF GYPSUM BOARD &
RELATED FINISHES TO FACE OF LIGHT GAUGE METAL FRAMING.
SEE INTERIOR ELEVATIONS.
2H2
DEMOLISH QUARRY TILE FLOORING, MORTAR, & DEBRIS FROM
CONCRETE SURFACE. GRIND SLAB SURFACE SMOOTH &
PREPARE TO RECEIVE NEW FINISH.
2H3
DEMOLISH QUARRY TILE WALL BASE.2H4
DEMOLISH FIRE EXTINGUISHER & BRACKET & SALVAGE FIRE
EXTINGUISHER FOR REINSTALLATION IN SAME LOCATION.
2J1
OWNER TO REMOVE EXISTING PORTABLE FOOD SERVICE
EQUIPMENT & FIXTURES EXCEPT WHERE NOTED OTHERWISE.
2K1
2E5 DEMOLISH SODA COUNTER AND SODA DISPENSERS,
RETURN EQUIPMENT TO OWNER
DEMOLISH DRIVE THRU WINDOW/ WINDOW SILL AND
SUPPORTING EQUIPMENT. PATCH/REPAIR ROUGH OPENING
TO RECEIVE NEW DRIVE-UP WINDOW.
2G2
DEMOLISH BULKHEAD.2H5
DEMOLISH EXISTING ACOUSTIC CEILING TILE SYSTEM
AND/OR GYPSUM CEILING SYSTEM.
2H6
DEMOLISH EXISTING TILE AND ASSOCIATED WALL
BASE. SALVAGE FOH TILE AND BASE FOR PATCHING.
2H7
2B2 DEMOLISH BOLLARD.
REMOVE EXISTING WALL PROTECTION, WALL COVERING
GRAPHIC, AND VINYL WALL BASE.
2H8
2C1 DEMOLISH AND SALVAGE BRICK FACE EXTERIOR
WALL. DEMOLISH ALL CONSTRUCTION OF WALL
INCLUDING FRAMING, INSULATION, AND FINISH.
OWNER TO REMOVE SHELVING.2L3
REMOVE EXISTING FRP FINISH AND GYPSUM BOARD TO
EXISTING WALL FRAMING.
2H9
REMOVE STAINLESS STEEL WALL PANELS. 2H10
2D1 DEMOLISH EXTERIOR CANOPY.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
X.
Y.
Z.
FIELD VERIFY ALL EXISTING CONDITIONS. NOTIFY ARCHITECT /
ENGINEER IMMEDIATELY OF ANY DISCREPANCIES THAT EXIST.
REMOVE EXISTING CONSTRUCTION AS NOTED AND WHERE SHOWN
DASHED. CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION
REQUIRED FOR THE INSTALLATION OF NEW WORK, AND FOR
PROTECTION OF ITEMS TO REMAIN.
CONTRACTOR IS RESPONSIBLE FOR ANY DEMOLITION THAT IS NOT
SHOWN ON DEMOLITION DRAWINGS BUT IS REQUIRED FOR NEW
CONSTRUCTION.
IF CONTRACTOR BECOMES AWARE OF ANY LOAD BEARING POINTS
WITHIN DEMOLITION NOT NOTED ON THE DRAWINGS, THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT / ENGINEER
PRIOR TO REMOVING THE CONSTRUCTION.
PATCH OPENINGS IN WALLS, CEILINGS AND FLOORS RESULTING
FROM DEMOLITION WORK. PATCH WITH MATCHING MATERIALS AND
CONSTRUCTION UNLESS NOTED OTHERWISE.
THE OWNER HAS FIRST RIGHT OF REFUSAL OF ALL SALVAGEABLE
ITEMS REMOVED DURING DEMOLITION INCLUDING FURNISHINGS.
CUT OPENINGS IN FLOOR AND ROOF STRUCTURE FOR NEW
MECHANICAL AND ELECTRICAL DUCTWORK, PIPING AND CONDUIT.
REINFORCE OPENINGS AS REQUIRED. SAW CUT AND PATCH
EXISTING FLOOR SLABS AS REQUIRED FOR NEW PIPING. REFER TO
PLUMBING DRAWINGS.
REFER TO MECHANICAL/ELECTRICAL PLANS AND SPECIFICATIONS
FOR REMOVAL/RELOCATION/REROUTING OF EXISTING UTILITIES.
DEMOLITION OF EXISTING UTILITIES SHALL BE MADE SO THAT
SERVICE TO OTHER AREAS UTILIZED BY THE OWNER ARE NOT
INTERRUPTED. PROVIDE TEMPORARY UTILITIES, ISOLATION VALVES,
DISCONNECTS, ETC. WHERE REQUIRED DURING DEMOLITION AND
NEW CONSTRUCTION.
WHERE EXISTING ELECTRICAL DEVICES ARE INDICATED TO BE
REMOVED, REPAIR WALL AS REQUIRED TO MATCH EXISTING (TO
REMAIN) WALL RATING. PATCH WALL AS REQUIRED TO RECEIVE NEW
FINISHES FOR A SMOOTH, FLUSH APPEARANCE.
REMOVE EXISTING CEILINGS WHERE REFLECTED CEILING PLANS
INDICATE NEW CEILINGS.
REMOVE ALL EXISTING FLOOR FINISHES, ADHESIVES AND WALL BASE
WHERE NEW FLOOR FINISH IS REQUIRED. REFER TO ROOM FINISH
SCHEDULE. PREPARE EXISTING FLOOR SUBSTRATE TO RECEIVE
NEW FLOOR FINISHES AS RECOMMENDED BY FLOOR FINISH
MANUFACTURER.
PROVIDE DUST BARRIERS AS REQUIRED TO PREVENT MIGRATION TO
AREAS TO BE OCCUPIED BY OWNER. PROTECT ALL EQUIPMENT TO
REMAIN. COORDINATE PROTECTION OF EXISTING EQUIPMENT WITH
OWNER.
COORDINATE DEMOLITION WITH SEQUENCING OF THE WORK.
PROTECT EXISTING FINISHES WHICH ARE TO REMAIN.
REFER TO STRUCTURAL DRAWINGS FOR SCOPE OF STRUCTURAL
DEMOLITION WORK.
CONDUCT DEMOLITION ACTIVITIES CLEANLY, COMPLETELY AND IN A
MANNER SUITABLE FOR NEW FINISHES.
WHILE DEMOLITION IS OCCURRING, SENSITIVE OWNER ACTIVITIES
WILL BE PROCEEDING IN ADJACENT AREAS. MINIMIZE NOISE AND
DUST LEVELS AND TEMPORARILY SUSPEND DEMOLITION AS
REQUESTED BY THE OWNER.
PROVIDE TEMPORARY PARTITIONS TO MAINTAIN PROPER FIRE EXITS
AND TO CONFINE PEDESTRIAN ACTIVITY TO OCCUPIED SPACES
MAINTAIN REQUIRED MEANS OF EGRESS AND SIGNAGE FOR
EGRESS.
WHERE DEMOLITION ACTIVITY DAMAGES OR REMOVES ANY APPLIED
FIREPROOFING OR CONSTRUCTION INSTALLED AS PART OF A RATED
ASSEMBLY, REPLACE FIREPROOFING AND CONSTRUCTION
MATERIALS TO ACHIEVE AND MAINTAIN APPROPRIATE ASSEMBLY
RATING.
VERIFY FLOOR ELEVATIONS ON EACH SIDE OF WALLS BEING
REMOVED. GRIND AND PATCH FLOOR AND INSTALL EPOXY FILL
MATERIAL AS REQUIRED FOR A SMOOTH LEVEL FLOOR CONDITION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN-UP
COST FOR DUST AND DEBRIS WHICH MIGRATE INTO EXISTING,
ADJACENT SPACES.
REMOVE ALL EXISTING WALL-MOUNTED ITEMS WITHIN THE PROJECT
LIMITS WHICH ARE NOT INDICATED TO REMAIN. IF ITEMS ARE
REMOVED FROM WALLS OR COLUMNS THAT REMAIN, PATCH WALLS
AND COLUMNS AS REQUIRED TO RECEIVE NEW FINISHES.
PATCH ALL FLOOR PENETRATIONS RESULTING FROM REMOVAL OF
EXISTING DUCTWORK, PIPING ELECTRICAL RACEWAYS, ETC. FILL
PENETRATION WITH CONCRETE, FULL FLOOR THICKNESS AND
MAINTAIN FIRE-RESISTIVE RATING OF FLOOR SYSTEM. FINISH
CONCRETE IN MANNER SUITABLE FOR NEW FLOOR FINISHES.
PATCH ALL WALL INTERSECTIONS AND PENETRATIONS RESULTING
FROM THE REMOVAL OF EXISTING WALLS, DUCTWORK, PIPING,
ELECTRICAL RACEWAYS, ETC. IN THE INTERIOR WALLS TO REMAIN.
THE PENETRATIONS SHALL BE FILLED FLUSHED WITH AND OF THE
SAME MATERIALS AS THE SURROUNDING WALLS (INCLUDES WORK
ABOVE CEILINGS).
DEMOLITION SHALL NOT INTERFERE WITH ADJACENT TENANTS DAILY
OPERATION OR DAILY OPERATION OF BUILDING.
GENERAL DEMOLITION NOTES:
D-6.01
2H1
2H1
2H1
2H1 2H1
2H1
2E3
2E4
2E1
2H4
2H4
2H4
2H4
2H4
2E2
2E5 2G1
2H3
2K1
2K2
2K4
2K4
2L1
2L1 2L1
2L2
2O1
2O2
2M1
2P1
2P2
2G2
D-6.01 23
2P3
2K3
2K3
2J1
2L1
2L1
D-6.01 4
2L1 2E3
2K22K1
2E5
2E52J1
2H7
D-6.01
2B2
2H8
2H7
2B2
2L3
2L3
2H9
2H9
2H9
2H9
2H9
A-6.0110
2H3
2H3
2H4
2H4
2H5
2H10
2H9
2H9
2H9
2H2
A-1.01
SALVAGE TILE AND BASE FOR PATCHING
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
As indicated10.23.2023
D-1.01 3740-23-000003
DEMOLITION FLOOR
PLAN
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
North 1/4" = 1'-0"
FIRST FLOOR DEMOLITION FLOOR PLAN
FE
C
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
1.
2.
3.
4.
5.
6.
7.
REFER TO PLUMBING DEMOLITION SHEET FOR DEMOLITION OF
EXISTING PLUMBING FIXTURES, FLOOR SINKS, & UNDERSLAB PIPING.
PROTECT ALL EXISTING UNDERSLAB PIPING TO REMAIN.
REFER TO DEMOLITION INTERIOR ELEVATION SHEETS FOR REMOVAL
OF CONSTRUCTION RELATED TO WALL DEMOLITION INCLUDING
DOORS, FRAMES & OTHER MISCELLANEOUS ITEMS.
REFER TO PLUMBING/MECHANICAL/ELECTRICAL SHEETS FOR
DEMOLITION OF PLUMBING FIXTURES, PIPING, DIFFUSERS, DEVICES,
WIRING, ELECTRICAL FIXTURES & MISCELLANEOUS
PLUMBING/MECHANICAL/ELECTRICAL ITEMS.
ITEMS NOT NOTED ARE EXISTING TO REMAIN OR REMOVED BY
OTHERS.
CONTRACTOR SHALL LOCATE, IDENTIFY & PROTECT ALL EXTERIOR &
INTERIOR PIPING & CONDUITS INCLUDING ELECTRICAL CIRCUITS,
PLUMBING WASTE PIPING, POWER, WATER SEWER & NATURAL GAS
SERVICES PRIOR TO COMMENCEMENT OF SLAB DEMOLITION &
EXCAVATION.
PROTECT EXISTING EDGE & SURFACES TO REMAIN ALONG ALL
SAWCUTS WHERE CONCRETE FLOOR SLAB IS NOTED TO BE
CUT/DEMOLISHED.
CONCRETE FLOOR SLAB AND FLOORING TO BE REMOVED AS
REQUIRED FOR UNDERGROUND UTILITIES WORK. REFER TO
SECTION 014516 QUALITY CONTROL, SECTION 014529 TESTING
LABORATORY SERVICES, SECTION 033000 CAST-IN-PLACE
CONCRETE, SECTION 312000 EARTHWORK, ARCHITECTURAL,
PLUMBING AND ELECTRICAL DRAWINGS FOR PROPOSED LOCATIONS.
ONCE SUITABLE BEARING CONDITIONS ARE DETERMINED BY THE
TESTING AGENCY, PROVIDE TESTED COMPACTED STONE, VAPOR
BARRIER AND DOWEL EXISTING CONCRETE SLAB INTO NEW
CONCRETE SLAB WITH REBAR, SIZE AND SPACING, TO BE
DETERMINED, REVIEWED AND APPROVED BY CONTRACTING
OFFICER BEFORE INSTALLATION.
TYPICAL NOTES:
DEMOLITION FLOOR SLAB NOTES:
SAWCUT PERIMETER OF AREA INDICATED, DEMOLISH
REINFORCED CONCRETE SLAB-ON- GRADE & BASE
COURSE AS INDICATED TO REQUIRED SUBGRADE.
SCARIFY & PREPARE SUB-BASE TO RECEIVE NEW BASE
COURSE MATERIALS, VAPOR BARRIER, & FLOOR SLAB.
SALVAGE MIN. 2'-0" OF EXG. VAPOR BARRIER AROUND
PERIMETER FOR LAPPING WITH NEW.
EXISTING GREASE WASTE LINE. SEE PLUMBING
SHEETS.
EXISTING SOIL, WASTE, OR SANITARY SEWER LINE. SEE
PLUMBING SHEETS.
2B1
2B3
2B4
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
X.
Y.
Z.
FIELD VERIFY ALL EXISTING CONDITIONS. NOTIFY ARCHITECT /
ENGINEER IMMEDIATELY OF ANY DISCREPANCIES THAT EXIST.
REMOVE EXISTING CONSTRUCTION AS NOTED AND WHERE SHOWN
DASHED. CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION
REQUIRED FOR THE INSTALLATION OF NEW WORK, AND FOR
PROTECTION OF ITEMS TO REMAIN.
CONTRACTOR IS RESPONSIBLE FOR ANY DEMOLITION THAT IS NOT
SHOWN ON DEMOLITION DRAWINGS BUT IS REQUIRED FOR NEW
CONSTRUCTION.
IF CONTRACTOR BECOMES AWARE OF ANY LOAD BEARING POINTS
WITHIN DEMOLITION NOT NOTED ON THE DRAWINGS, THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT / ENGINEER
PRIOR TO REMOVING THE CONSTRUCTION.
PATCH OPENINGS IN WALLS, CEILINGS AND FLOORS RESULTING
FROM DEMOLITION WORK. PATCH WITH MATCHING MATERIALS AND
CONSTRUCTION UNLESS NOTED OTHERWISE.
THE OWNER HAS FIRST RIGHT OF REFUSAL OF ALL SALVAGEABLE
ITEMS REMOVED DURING DEMOLITION INCLUDING FURNISHINGS.
CUT OPENINGS IN FLOOR AND ROOF STRUCTURE FOR NEW
MECHANICAL AND ELECTRICAL DUCTWORK, PIPING AND CONDUIT.
REINFORCE OPENINGS AS REQUIRED. SAW CUT AND PATCH
EXISTING FLOOR SLABS AS REQUIRED FOR NEW PIPING. REFER TO
PLUMBING DRAWINGS.
REFER TO MECHANICAL/ELECTRICAL PLANS AND SPECIFICATIONS
FOR REMOVAL/RELOCATION/REROUTING OF EXISTING UTILITIES.
DEMOLITION OF EXISTING UTILITIES SHALL BE MADE SO THAT
SERVICE TO OTHER AREAS UTILIZED BY THE OWNER ARE NOT
INTERRUPTED. PROVIDE TEMPORARY UTILITIES, ISOLATION VALVES,
DISCONNECTS, ETC. WHERE REQUIRED DURING DEMOLITION AND
NEW CONSTRUCTION.
WHERE EXISTING ELECTRICAL DEVICES ARE INDICATED TO BE
REMOVED, REPAIR WALL AS REQUIRED TO MATCH EXISTING (TO
REMAIN) WALL RATING. PATCH WALL AS REQUIRED TO RECEIVE NEW
FINISHES FOR A SMOOTH, FLUSH APPEARANCE.
REMOVE EXISTING CEILINGS WHERE REFLECTED CEILING PLANS
INDICATE NEW CEILINGS.
REMOVE ALL EXISTING FLOOR FINISHES, ADHESIVES AND WALL BASE
WHERE NEW FLOOR FINISH IS REQUIRED. REFER TO ROOM FINISH
SCHEDULE. PREPARE EXISTING FLOOR SUBSTRATE TO RECEIVE
NEW FLOOR FINISHES AS RECOMMENDED BY FLOOR FINISH
MANUFACTURER.
PROVIDE DUST BARRIERS AS REQUIRED TO PREVENT MIGRATION TO
AREAS TO BE OCCUPIED BY OWNER. PROTECT ALL EQUIPMENT TO
REMAIN. COORDINATE PROTECTION OF EXISTING EQUIPMENT WITH
OWNER.
COORDINATE DEMOLITION WITH SEQUENCING OF THE WORK.
PROTECT EXISTING FINISHES WHICH ARE TO REMAIN.
REFER TO STRUCTURAL DRAWINGS FOR SCOPE OF STRUCTURAL
DEMOLITION WORK.
CONDUCT DEMOLITION ACTIVITIES CLEANLY, COMPLETELY AND IN A
MANNER SUITABLE FOR NEW FINISHES.
WHILE DEMOLITION IS OCCURRING, SENSITIVE OWNER ACTIVITIES
WILL BE PROCEEDING IN ADJACENT AREAS. MINIMIZE NOISE AND
DUST LEVELS AND TEMPORARILY SUSPEND DEMOLITION AS
REQUESTED BY THE OWNER.
PROVIDE TEMPORARY PARTITIONS TO MAINTAIN PROPER FIRE EXITS
AND TO CONFINE PEDESTRIAN ACTIVITY TO OCCUPIED SPACES
MAINTAIN REQUIRED MEANS OF EGRESS AND SIGNAGE FOR
EGRESS.
WHERE DEMOLITION ACTIVITY DAMAGES OR REMOVES ANY APPLIED
FIREPROOFING OR CONSTRUCTION INSTALLED AS PART OF A RATED
ASSEMBLY, REPLACE FIREPROOFING AND CONSTRUCTION
MATERIALS TO ACHIEVE AND MAINTAIN APPROPRIATE ASSEMBLY
RATING.
VERIFY FLOOR ELEVATIONS ON EACH SIDE OF WALLS BEING
REMOVED. GRIND AND PATCH FLOOR AND INSTALL EPOXY FILL
MATERIAL AS REQUIRED FOR A SMOOTH LEVEL FLOOR CONDITION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN-UP
COST FOR DUST AND DEBRIS WHICH MIGRATE INTO EXISTING,
ADJACENT SPACES.
REMOVE ALL EXISTING WALL-MOUNTED ITEMS WITHIN THE PROJECT
LIMITS WHICH ARE NOT INDICATED TO REMAIN. IF ITEMS ARE
REMOVED FROM WALLS OR COLUMNS THAT REMAIN, PATCH WALLS
AND COLUMNS AS REQUIRED TO RECEIVE NEW FINISHES.
PATCH ALL FLOOR PENETRATIONS RESULTING FROM REMOVAL OF
EXISTING DUCTWORK, PIPING ELECTRICAL RACEWAYS, ETC. FILL
PENETRATION WITH CONCRETE, FULL FLOOR THICKNESS AND
MAINTAIN FIRE-RESISTIVE RATING OF FLOOR SYSTEM. FINISH
CONCRETE IN MANNER SUITABLE FOR NEW FLOOR FINISHES.
PATCH ALL WALL INTERSECTIONS AND PENETRATIONS RESULTING
FROM THE REMOVAL OF EXISTING WALLS, DUCTWORK, PIPING,
ELECTRICAL RACEWAYS, ETC. IN THE INTERIOR WALLS TO REMAIN.
THE PENETRATIONS SHALL BE FILLED FLUSHED WITH AND OF THE
SAME MATERIALS AS THE SURROUNDING WALLS (INCLUDES WORK
ABOVE CEILINGS).
DEMOLITION SHALL NOT INTERFERE WITH ADJACENT TENANTS DAILY
OPERATION OR DAILY OPERATION OF BUILDING.
GENERAL DEMOLITION NOTES:
2B1
2B1
2B1
2B1
2B1
NOT IN SCOPE
2B1
2B3
2B4
A-1.01
2B1
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
As indicated10.23.2023
D-1.02 3740-23-000003
DEMOLITION FLOOR
SLAB PLAN
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
North 1/4" = 1'-0"
FIRST FLOOR DEMOLITION FLOOR SLAB PLAN
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
DEMOLITION NOTES:
2E1
2E2 DEMOLISH QUEUE LINE RAILS AND PATCH/PREPARE
FLOOR FOR NEW FINISH.
2E3 DEMOLISH PLASTIC LAMINATE BASE CABINETS,
COUNTERTOPS, & SHELVING.
DISCONNECT ALL HARDWIRED & PIPED FOOD SERVICE
EQUIPMENT & DELIVER TO EXCHANGE DESIGNATED ON-SITE
STORAGE. SEE PLUMBING & ELECTRICAL DEMO SHEETS FOR
DEMOLITION OF SERVICES.
2K2
MAINTAIN INSULATED FREEZER FLOOR, WALL, & ROOF PANELS,
DOOR & RELATED HARDWARE. PROTECT UNIT DURING
DEMOLITION AND CONSTRUCTION. REPAIR OR REPLACE ANY
DAMAGE AT SUBSTANTIAL COMPLETION BACK TO EXISTING
CONDITION AT START OF CONSTRUCTION.
2K3
OWNER TO REMOVE EXISTING FURNITURE.2L1
SEE "PD" SHEETS FOR DEMOLITION OF EXISTING SINK AND
RELATED PIPING.
2O1
SEE PD SHEETS FOR DEMOLITION OF WATER FILTER AND
RELATED PIPING.
2O2
SEE "ED" SHEETS FOR DEMOLITION OF EXISTING J-BOXES,
CONDUIT & WIRING WHERE APPLICABLE.
2P2
SEE "ED" SHEETS FOR DEMOLITION OF EXISTING POWER PANEL,
CONDUIT & WIRING.
2P3
DEMOLISH WALL SHELVES & STANDARDS.
2E4 DEMOLISH SOLID SURFACE COUNTERTOP.
OWNER TO RELOCATE EXISTING TRASH UNITS AND LOOSE
FURNITURE.
2L2
MAINTAIN ELECTRICAL PANELS, PROTECT FROM DAMAGE
DURING CONSTRUCTION .
2P1
SEE PD SHEETS FOR DEMOLITION OF ANSUL SYSTEM.2M1
DEMOLISH INTERIOR WOOD DOOR, H.M. FRAME, HARDWARE &
RELATED CONSTRUCTION.
2G1
DEMOLISH LIGHT GAUGE METAL STUD FRAMED GYPSUM
BOARD PARTITION & RELATED FINISHES INCLUDING GLAZED
WALL TILE AND OR WOOD WALL PANELS
2H1
CUT & DEMOLISH DESIGNATED PORTION OF GYPSUM BOARD &
RELATED FINISHES TO FACE OF LIGHT GAUGE METAL FRAMING.
SEE INTERIOR ELEVATIONS.
2H2
DEMOLISH QUARRY TILE FLOORING, MORTAR, & DEBRIS FROM
CONCRETE SURFACE. GRIND SLAB SURFACE SMOOTH &
PREPARE TO RECEIVE NEW FINISH.
2H3
DEMOLISH QUARRY TILE WALL BASE.2H4
DEMOLISH FIRE EXTINGUISHER & BRACKET & SALVAGE FIRE
EXTINGUISHER FOR REINSTALLATION IN SAME LOCATION.
2J1
OWNER TO REMOVE EXISTING PORTABLE FOOD SERVICE
EQUIPMENT & FIXTURES EXCEPT WHERE NOTED OTHERWISE.
2K1
2E5 DEMOLISH SODA COUNTER AND SODA DISPENSERS,
RETURN EQUIPMENT TO OWNER
DEMOLISH DRIVE THRU WINDOW/ WINDOW SILL AND
SUPPORTING EQUIPMENT. PATCH/REPAIR ROUGH OPENING
TO RECEIVE NEW DRIVE-UP WINDOW.
2G2
DEMOLISH BULKHEAD.2H5
DEMOLISH EXISTING ACOUSTIC CEILING TILE SYSTEM
AND/OR GYPSUM CEILING SYSTEM.
2H6
DEMOLISH EXISTING TILE AND ASSOCIATED WALL
BASE. SALVAGE FOH TILE AND BASE FOR PATCHING.
2H7
2B2 DEMOLISH BOLLARD.
REMOVE EXISTING WALL PROTECTION, WALL COVERING
GRAPHIC, AND VINYL WALL BASE.
2H8
2C1 DEMOLISH AND SALVAGE BRICK FACE EXTERIOR
WALL. DEMOLISH ALL CONSTRUCTION OF WALL
INCLUDING FRAMING, INSULATION, AND FINISH.
OWNER TO REMOVE SHELVING.2L3
REMOVE EXISTING FRP FINISH AND GYPSUM BOARD TO
EXISTING WALL FRAMING.
2H9
REMOVE STAINLESS STEEL WALL PANELS. 2H10
2D1 DEMOLISH EXTERIOR CANOPY.
FIRST FLOOR
0"
2G1
2H1
2L1
2H1
2L2
2E4
2E3
2K4
2K4
2H5
2H1
2H6
2H4
2H1
A-7.01
FIRST FLOOR
0"
2H1
2H6
2H4
FIRST FLOOR
0"
2G2
2H4
2H10
2H9
2H9
A-1.01
FIRST FLOOR
0"
33012
2G2
2B22B2
2C1
2D12D1
FIRST FLOOR
0"
2K4
FIRST FLOOR
0"
2H8
2E5
2E52E5
EXISTING
TO REMAIN
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
As indicated10.23.2023
D-6.01 3740-23-000003
DEMOLITION
ELEVATIONS
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
3/8" = 1'-0"
DEMOLITION INTERIOR ELEVATION
1/4" = 1'-0"
DEMOLITION INTERIOR ELEVATION
1/4" = 1'-0"
DEMOLITION INTERIOR ELEVATION
1/4" = 1'-0"
WEST ELEVATION DEMOLITION
1/4" = 1'-0"
SOUTH ELEVATION DEMOLITION
1/4" = 1'-0"
DEMOLITION INTERIOR ELEVATION
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
S
S S
S S
S
S
S
TYPICAL NOTES:
1.
2.
3.
4.
5.
REFER TO DEMOLITION INTERIOR ELEVATION SHEETS FOR
REMOVAL OF CONSTRUCTION RELATED TO WALL DEMOLITION
INCLUDING DOORS, FRAMES & OTHER MISCELLANEOUS ITEMS.
REFER TO MECHANICAL/ELECTRICAL SHEETS FOR DEMO OF
PLUMBING, HVAC ITEMS, WIRING, DEVICES, LIGHTING FIXTURES
& MISCELLANEOUS ELECTRICAL ITEMS.
ITEMS NOT NOTED ARE EXISTING TO REMAIN OR REMOVED BY
OTHERS.
CONTRACTOR SHALL LOCATE, IDENTIFY & PROTECT ALL
EXTERIOR & INTERIOR PIPING & CONDUITS RELATED TO AREA
OF WORK, INCLUDING ELECTRICAL CIRCUITS, PLUMBING WASTE
PIPING, POWER, WATER SEWER & NATURAL GAS SERVICES
PRIOR TO COMMENCEMENT OF SLAB DEMOLITION &
EXCAVATION.
PATCH & PREPARE GYPSUM BOARD WALL SURFACES TO
REMAIN TO RECEIVE NEW FINISH.
DEMOLITION NOTES:
DEMOLISH LAY-IN ACOUSTICAL TILE CEILING PADS & GRID
SYSTEM.
DEMOLISH LIGHT GAUGE METAL STUD FRAMED GYPSUM BOARD
FASCIA/SOFFIT IN ENTIRETY.
CUT & DEMOLISH DESIGNATED PORTION OF LIGHT GAUGE METAL
STUD FRAMED GYPSUM BOARD SOFFIT/FASCIA.
SEE "MD" SHEETS FOR DEMOLITION OF EXISTING HVAC DUCTS,
GRILLES & DIFFUSERS.
SEE "MD & ED" SHEETS FOR DEMOLITION OF EXISTING EXHAUST
FAN OR HOOD, POWER & ASSOCIATED DUCTWORK.
SEE "FPD" SHEETS FOR DEMOLITION OF/ REVISIONS TO EXISTING
SPRINKLER HEADS/DROPS.
SEE "ED" SHEETS FOR DEMOLITION OF EXISTING INTERIOR
LIGHTING FIXTURES, LAMPS & BALLASTS.
SEE "ED" SHEETS FOR DEMOLITION OF EXISTING J-BOXES,
CONDUIT & WIRING WHERE APPLICABLE.
2H1
2H2
2H3
2O1
2O2
2O3
2P1
2P2
C C
TV
C C
TV
C C
TV
JIMMY JOHNS NOT IN SCOPE
F F
H O
O D
H O
O D
8'
3/
8"
7'
8'
3/
4" C
EI
LI
N G
7' -1
3/
4" A
FF
C
EI
LI
N
G 8'
-1
/4 " A
FF
TR
U
N K
LI
N
E D
U C
T H
ER
AT
9' -1
1" T
O B
O
TT
O M
W
IF
I
C C
TV2H1
2H1
2H1
2H1
2H1
2H2
2O32O1
2O2 2P12P2
9' - 10"
2P1 2P1 2P1
2H2
2P1 2P1
2P1
2P1
2P1
2P1 2P1
2P1
2P12P12P1
2P1 2P1 2P1
2P1 2P1 2P1
2P1
2P1 2P1
2O2
2O2
8' - 1"
9' - 10"
9' - 4 3/4"
9' - 5"
9' - 6"
9' - 6 1/4"
2H1
E CHANGE
ECIVRESEGNAHCXEECROFRIA&YMRA
TM
AR
C
H
IT
EC
TS
c h.
m ic ha el b oh ns ac k
DESIGN BY:
CHECKED BY:
APPROVED:
RECOMMENDED:
PROJECT:
ARMY & AIR FORCE EXCHANGE SERVICE
DEPARTMENTS OF THE ARMY & AIR FORCE
DRAWING TITLE:
SHEET NO:
DRAWING PROJECT NO.
DATE: SCALE:
OF
RE-C
REAL ESTATE DIRECTORATE
DATE
DATE
KEYPLAN:
DATE
SEAL:
CONSULTANT:
REVISION N0. & DESCRIPTION BY
ARCHITECT:
LICENSE
EXPIRATION DATE
CURRENT DATE
As indicated10.23.2023
D-7.01 3740-23-000003
DEMOLITION
REFLECTED CEILING
PLAN
CONVERT BK TO
PANERA WITH
DRIVE-THRU
Ft. Cavazos, Texas
N/A
North 1/4" = 1'-0"
DEMOLITION REFLECTED CEILING PLAN
T
R
S
L
IC
E NSE D A
JARUS
TI
CH
C E
SI
L
TA
E O IF
NIL
O
K. JONES
GENERAL FLOOR PLAN NOTES:
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
ALL DIMENSIONS ON FLOOR PLANS ARE FROM FACE OF FINISH
GYPSUM BOARD, FACE OF MASONRY, FACE OF CONCRETE OR
CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE.
ALL NEW GYPSUM BOARD CONSTRUCTION TO BE PAINTED UNLESS
NOTED OTHERWISE.
CONTRACTOR SHALL PATCH AND MATCH EXISTING WALL FINISHES
WITH LIKE MATERIALS AND FINISHES WHERE DISTURBED BY NEW
CONSTRUCTION.
OUTSIDE EDGE OF INTERIOR DOOR FRAME JAMBS TYPICALLY
LOCATED 4" FROM ADJACENT WALL UNLESS NOTED OTHERWISE.
PROVIDE MIN. (2) 20 GA. METAL STUDS AT HEAD AND JAMB OF DOOR
OPENING.
PROVIDE 5/8" CEMENT BACKING BOARD ON ALL KITCHEN, RESTROOM,
& OFFICE WALLS FROM FLOOR TO 2'-0" A.F.F. AT WORKROOM WALLS
WITH TILE FINISH, PROVIDE CEMENT BOARD TO 6'-0" A.F.F.
PROVIDE 5/8" FIRE-TREATED PLYWOOD BACKING BOARD ON KITCHEN
& OFFICE WALLS (2'-0" AFF TO CEILING), SEE PARTITION SCHEDULE
FOR WORKROOM WALLS W/ TILE FINISH.
CONTRACTOR SHALL PROVIDE BLOCKING IN WALLS, CEILINGS, AND
ANY OTHER LOCATION AS REQUIRED FOR INSTALLATION OF
CASEWORK, SURFACE MOUNTED ITEMS, PROJECTION SCREENS,
MARKER BOARDS, TOILET ACCESSORIES, SINK ACCESSORIES, WALL
MOUNTED DOOR STOPS, AND ANY OTHER SURFACE MOUNTED ITEMS.
FOR WALL TYPES REFER TO THE WALL TYPES SCHEDULE ON SHEET
T-1.01.
FOR INTERIOR FINISHES REFER TO THE ROOM FINISH SCHEDULE ON
SHEET A-9.01.
CONTRACTOR SHALL PROVIDE ACCESS PANELS IN WALLS WHERE
SERVICE TO MECHANICAL, PLUMBING, ELECTRICAL, ETC. ELEMENTS
ARE TO BE ADJUSTED I.E. CLEANOUTS, VALVES DAMPERS, ETC.
ACCESS PANELS SHALL BE OF THE SAME RATING AS THE ADJACENT
WALL CONSTRUCTION.
CONTRACTOR SHALL PROVIDE CEMENT BOARD AT ALL WALL TILE
LOCATIONS UNLESS NOTED OTHERWISE.
CONTRACTOR SHALL PATCH FLOORING AND WHERE WALL BASE HAS
BEEN REMOVED DURING DEMOLITION WITH FLOORING AND BASE THAT
MATCHES EXISTING, ADJACENT FLOOR FINISHES UNLESS NOTED
OTHERWISE.
REFER TO ELEVATIONS AND DETAILS FOR CLARIFICATION OF WALL
FINISH EXTENTS.
CONTRACTOR SHALL CAULK DOOR FRAME FROM FLOOR
CONTINUOUSLY AT THE PERIMETER OF DOOR AND WINDOW FRAMES.
CAULK AFTER WALL COVERING IS INSTALLED (IF SPECIFIED).
MAINTAIN FIRE RATED ASSEMBLY IN WALLS, CEILINGS. FLOORS, ETC.
PROVIDE THROUGH-PENETRATION FIRESTOP SYSTEMS AT ALL
PENETRATIONS IN FIRE-RATED ASSEMBLIES. PROVIDE FIRE-RESISTIVE
JOINT SYSTEMS AT ALL JOINTS BETWEEN FIRE-RATED ASSEMBLIES
AND ADJACENT CONSTRUCTION.
HOLD GYPSUM BOARD 1/4" FROM FLOOR, CEILING AND ANY ADJACENT
SURFACE AND PROVIDE A CONTINUOUS BEAD OF ACOUSTICAL
SEALANT AROUND PERIMETER OF ACOUSTICAL PARTITIONS ON EACH
SIDE OF THE WALL. PROVIDE ACOUSTICAL FIRE SEALANT AT FIRE-
RATED PARTITIONS.
CONSTRUCTION AND INSTALLATIONS SHALL CONFORM TO
APPLICABLE FEDERAL, STATE LOCAL ORDINANCES, CODES, ETC.
ALL FIRE-RATED ASSEMBLIES WITH RECESSED WALL ACCESSORIES
AND/OR PENETRATIONS I.E. RECEPTACLES, CONDUITS, DUCTS, PIPING,
FIRE EXTINGUISHER CABINETS, PAPER TOWEL DISPENSERS. ETC.
SHALL BE CONSTRUCTED TO MAINTAIN THE DESIGNATED ASSEMBLY
RATING.
ALL PENETRATIONS THROUGH FLOORS, CHASES, SHAFTS AND FIRE
RATED ASSEMBLIES SHALL BE FIRE-STOPPED.
ALL HOLLOW METAL FRAMES TO BE PAINTED.
CONTRACTOR SHALL CAULK ALL DISSIMILAR MATERIALS (ie. DRYWALL, STOREFRONT.
PROVIDE 2" AIR SPACE AT SIDE(S) OF OVEN/PROOFER &
COOLER/FREEZER (MIN. 3" AT BACK OF OVEN). VERIFY ALL
DIMENSIONS & SPECS WITH EQUIPMENT MANUAL. NO FINISH ON
WALLS BEHIND OVEN/PROOFER & COOLER/FREEZER (TAPE & PRIME
ONLY).
FLOOR PLAN REFERENCE NOTES:
EXISTING COOLER/FREEZER TO REMAIN, PROTECT DURING
CONSTRUCTION.
NEW ELECTRICAL PANEL(S) LOCATION.
EXISTING BAG IN BOX…
This is the start of the file's text. The full file is on GovTribe.