About this file

These specifications detail the procurement of a Medium Head Oxygenator (MHO) for the Ouray National Fish Hatchery – Randlett Unit in Randlett, Utah. The MHO is for a Recirculating Aquaculture System, with specific technical requirements including a 6-inch discharge and intake size, maximum flow of 315 gpm, minimum flow of 200 gpm, oxygen flow of 9 lpm, dissolved oxygen output of 28 ppm, and a transfer efficiency of 90%. The device will be located in the Filtration Room and is intended to supersaturate water with oxygen for fish production.

Delivery terms are FOB Destination to 21000 West Wildlife Refuge Road, Randlett, Utah 84078. The contractor must contact Zane Olsen (Project Leader, cell: 435-899-0503) at least 3 days before delivery to arrange a specific delivery time, with acceptances between 7:30 am and 3:00 pm, Monday through Friday, excluding federal holidays. The delivery site can accommodate large vehicles, and equipment is available on-site for unloading. The government will handle installation, and the contractor is responsible for packing, marking, and delivering the equipment in good condition, bearing all associated delivery charges.

View the file

Other files for this federal contract opportunity

Other files attached to UT - OURAY NFH - Medium Head Oxygenator, newest first.
File Type Posted
Sol_140FS225Q0192.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATIONS

Hatchery Building Medium Head Oxygenator Purchase for

Ouray National Fish Hatchery – Randlett Unit in Randlett, Utah

1. Product Features

Salient Characteristics: Medium Head Oxygenator to be used on a Recirculating Aquaculture System to supersaturate the water with oxygen for fish production.

Medium Head Oxygenator Specifications:

MHO Location: Filtration Room

Discharge Size: 6 Inch Intake Size: 6 Inch Max Flow: 315 gpm Min Flow: 200 gpm Oxygen flow In: 9 lpm Dissolved Oxygen Out: 28 ppm Oxygen Transfer: 0.6 kg/h Transfer Efficience: 90% Fall Through Gas Space: 24 inches Max Pressure: 15 PSI Extra Items: Any additional parts needed to operate the MHO.

Quantity Needed: 1 Consider Different Option: Yes

Capabilities (if applicable): Medium Head Oxygenator to be used on a Recirculating Aquaculture System to supersaturate the water with oxygen in fish culture operation and production.

2. Delivery

Prices quoted must be FOB Destination

“F.o.b. destination” means --Free of expense to the Government delivered, on board the carrier’s conveyance, at a specified delivery point where the consignee’s facility (plant, warehouse, store, lot, or other location to which shipment can be made) is located; and

Supplies shall be delivered to the destination consignee’s wharf (if destination is a port city and supplies are for export), warehouse unloading platform, or receiving dock, at the expense of the contractor. The Government shall not be liable for any delivery, storage, demurrage, accessorial, or other charges involved before the actual delivery (or “constructive placement” as defined in carrier tariffs) of the supplies to the destination, unless such charges are caused by an act or order of the Government acting in its contractual capacity. If rail carrier is used, supplies shall be delivered to the specified unloading platform of the consignee. If motor carrier (including “piggyback”) is used, supplies shall be delivered to truck tailgate at the unloading platform of the consignee, except when the supplies delivered meet the requirements of Item 568 of the National Motor Freight Classification for “heavy or bulky freight.” When supplies meeting the requirements of the referenced Item 568 are delivered, unloading (including movement to the tailgate) shall be performed by the consignee, with assistance from the truck driver, if requested. If the contractor uses rail carrier or freight forwarder for less than carload shipments, the contractor shall ensure that the carrier will furnish tailgate delivery when required, if transfer to truck is required to complete delivery to consignee.

Contractor responsibilities. The contractor shall -- (1)(i) Pack and mark the shipment to comply with contract specifications; or

(ii) In the absence of specifications, prepare the shipment in conformance with carrier requirements;

(2) Prepare and distribute commercial bills of lading;

(3) Deliver the shipment in good order and condition to the point of delivery specified in the contract;

(4) Be responsible for any loss of and/or damage to the goods occurring before receipt of the shipment by the consignee at the delivery point specified in the contract;

(5) Furnish a delivery schedule and designate the mode of delivering carrier; and

(6) Pay and bear all charges to the specified point of delivery.

3. Delivery Location:

Product shall be delivered to the following location:

21000 West Wildlife Refuge Road Randlett, Utah 84078

5. Technical Point of Contact (POC):

Zane Olsen, Ouray NFH, Project Leader

Cell PH: (435) 899-0503

Email address: zane_olsen@fws.gov

6. Delivery Instructions:

No later than 3 days prior to delivery, delivering company shall contact the Point of Contact listed above, to arrange a specific time for delivery. Deliveries will be accepted between 7:30 am to 3:00 pm, Monday through Friday. Deliveries on federal holidays will not be accepted. The delivery address can accommodate large vehicle with plenty of room to navigate large trucks. There is equipment on site to unload delivery.

7. Installation

Installation will be completed by Government staff.

mailto:zane_olsen@fws.gov