A06_NIFC_300-JWH_Suite_115_Drawings_11x17.pdf

PDF 6 MB Posted

Attached to
NIFC 300 JWH Suite 115 Updates
Solicitation number
140L3724R0009
Issued by

About this file

This document is a set of architectural and engineering drawings for the renovation of NIFC 300 JWH Suite 115 in Boise, Idaho. The project includes demolition of existing finishes, modifications to the HVAC system, electrical work, and installation of new finishes. Key elements include:

  • Removal of existing doors, windows, flooring, and ceiling tiles, with patching and preparation of surfaces for new construction.
  • Installation of new access control system, column wraps, and solid surface window sills.
  • Painting of existing walls, doors, and ladder.
  • New acoustical ceiling tile to be installed in existing grid.

The related federal contract opportunity is Solicitation Number 140L3724R0009 for the "NIFC 300 JWH Suite 115 Updates" renovation project, issued by the Department of the Interior Bureau of Land Management Idaho Region. The solicitation documents were issued for construction on May 23, 2024.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESIGNERS

ALWAYS THINK SAFETY

Project #

Sh ee t T itl e:

Date:

BLM Project #

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

D ra w n by

R ev is io ns

Ap pr ov ed b y:

C he ck ed b y:

D es ig ne d by

Seal:

Sheet of 21

05/24/2024

070117.020

140L0624F0022

N

IF

C

-J

W H

S U

IT

E

U

PD

AT

E

D ev el op m en t A ve

, B oi se , I

D

G-001

B.

C

AR

TE

R

A.

R

IC

O

B.

C

AR

TE

R

B.

C

AR

TE

R

C O

VE

R

S H

EE

T

VICINITY MAPSTATE REFERENCE MAP

PROJECT LOCATION

LATITUDE: 43.567070°

LONGITUDE: -116.209100°

3833 DEVELOPMENT AVE, BOISE, ID 83705

NATIONAL INTERAGENCY FIRE CENTER

NIFC 300-JWH SUITE 115 UPDATE

NATIONAL INTERAGENCY FIRE CENTER

BOISE, IDAHO

PROJECT

LOCATION

BOISE AIRPORT

INTERSTATE 84

NIFC CAMPUS

DRAWING INDEX

SHEET

SUB

SHEET TITLE OF SHEET

GENERAL

1 G-001 COVER SHEET

ARCHITECTURAL

2 AD101 FIRST FLOOR DEMOLITION PLANS

3 AD102 FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN

4 A-101 FIRST FLOOR PLAN

5 A-102 FIRST FLOOR REFLECTED CEILING PLAN

6 A-601 SCHEDULES AND DETAILS

INTERIORS

7 I-101 FINISH FLOOR PLAN

MECHANICAL

8 M-001 MECHANICAL LEGEND, NOTES AND ABBREVIATIONS

9 MD101 HVAC DEMOLITION FLOOR 1

10 MD401 ENLARGED HVAC DEMOLITION VIEWS

11 M-101 HVAC FLOOR 1

12 M-401 ENLARGED HVAC VIEWS

13 M-501 HVAC DETAILS

14 M-502 HVAC DETAILS

15 M-503 HVAC DETAILS

16 M-601 HVAC SCHEDULES

ELECTRICAL

17 E-001 ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS

18 ED101 DEMO PLAN SUITE 115

19 E-101 ELECTRICAL PLAN SUITE 115

20 E-102 LIGHTING PLAN SUITE 115

21 E-501 ELECTRICAL DETAILS

Ben Carter Digitally signed by Ben Carter Date: 2024.05.23 15:17:50 -06'00'

OPEN OFFICE

HALL

OFFICE

OFFICE

OFFICE

HUDDLE

OFFICE

OFFICE

E115.1

E111.1

5 5 5

4 1 4 1

4 1

4 1

31' - 4" V.I.F.

V .I .F

ROOM NAME AND NUMBER

KEYNOTE

DOOR NUMBER (SEE SHEET A601)

DIMENSION TO FACE OF FRAMING

-1

NAME

X

A. THESE DRAWINGS ARE BASED UPON EXISTING

DRAWINGS AND SITE OBSERVATIONS. THE

CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL

CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING

WORK.

B. ALL ITEMS, MATERIAL, AND EQUIPMENT, SPECIFICALLY

DETAILED OR NOT, THAT IS REQUIRED TO BE REMOVED

IN ORDER TO COMPLETE THE WORK AS DESCRIBED

SHALL BE INCLUDED IN THE BID.

C. UNKNOWN CONDITIONS THAT IMPACT THE BUILD BACK

OF THESE AREAS SHALL BE BROUGHT TO THE

ATTENTION OF THE ARCHITECT AS SOON AS

DISCOVERED.

D. OWNER SHALL REMOVE AND SALVAGE ALL WALL

MOUNTED EQUIPMENT, MOVEABLE FURNITURE AND

EQUIPMENT IN ALL SPACES WITH DEMOLITION WORK.

E. REMOVE DEBRIS FROM THE SITE IMMEDIATELY AND

DISPOSE OF LEGALLY, THE BUILDING AND GROUNDS

SHALL BE KEPT FREE OF DEBRIS AND REFUSE AT ALL

TIMES.

F. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING

CONTINUOUS ACCESS TO ALL EXITS AT ALL TIMES.

G. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING

AIR QUALITY AND DUST CONTROL DURING DEMOLITION

AND NEW CONSTRUCTION.

H. WHERE NEW FLOOR FINISH IS SCHEDULED, REMOVE

EXISTING FLOORING AND ADHESIVE TO SUBSTRATE.

1 2 3 4 5

D

C

B

A

S h e e t T it le

D e s ig n e d b y

D ra w n b y

C h e c k e d b y

A p p ro v e d b y

R e v is io n s

U n it e d S ta te s D e p a rt m e n t o f th e

I n te ri o r

B u re a u o f L a n d M a n a g e m e n t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

KEY PLAN VIEW

/2

/2

:1

:2

A

M C

U s e rs

\a lf o n s o ra m ir e z \D o c u m e n ts

R e v it L o c a lT e m p \L

B Y

D B

L M

T O a rc h a lf o n s o ra m ir e z .r v t

F

IR

S T

F L

O O

R D

E M

O L

IT

IO

N P

L A

N S K

E

D W

A R

D S

K

E D

W A

R D

S

A

R A

M

IR

E Z

S

R O

B E

R T

S

N

IF

C

-J W

H S

U

IT

E

U P

D A

T E

S D e v e lo p e m e n t

A v e

B o is e

ID

140L0622D0002

070117.020

05.23.2024

AD101

N A

T

IO

N A

L I

N T

E R

A G

E N

C Y

F

IR

E C

E N

T E

R

2 21

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

B1

FIRST FLOOR DEMOLITION PLAN

1 REMOVE WINDOW COVERINGS. GOVERNMENT TO

PROVIDE NEW BUILDING STANDARD SHADES.

2 REMOVE DOOR AND ASSOCIATED HARDWARE, EXISTING

DOOR FRAME TO REMAIN. SEE DOOR SCHEDULE ON

SHEET A-601.

3 REMOVE EXISTING DOOR, DOOR FRAME TO REMAIN.

PREP DOOR FRAME TO RECIEVE NEW ACCESS CONTROL

SYSTEM AND DOOR HARDWARE.

SEE SHEET A-601 FOR DOOR HARDWARE AND ELECTRICAL

DRAWINGS FOR FURTHER REQUIREMENTS.

4 REMOVE ALL CARPET, WALL BASE, AND ANY WALL

HANGING ITEMS. PATCH DRYWALL AS NEEDED.

5 REMOVE WINDOW SILL AND PREPARE SUBSTRATE FOR

NEW SOLID SURFACE SILL.

0 2' 4' 8'

N

SHEET KEYNOTES

PLAN LEGEND

GENERAL DEMO NOTES

D es cr ip tio n D at e

0%

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

5.

.2

OFFICE

OPEN OFFICE

HALL

OFFICE

OFFICE

OFFICE

HUDDLE

OFFICE

HALL

1 1 1

CEILING MATERIAL

CEILING HEIGHT

ADDITIONAL NOTES

2X4 ACOUSTICAL

LAY-IN CEILING TILE

TO BE REMOVED.

GRID TO REMAIN.

EXISTING

GYPSUM BOARD

CEILING - PAINT

ACT

VARIES

NOTES

EXISTING SOUND

INSULATION ABOVE

CEILING TO REMAIN.

1 2 3 4 5

D

C

B

A

S h e e t T it le

D e s ig n e d b y

D ra w n b y

C h e c k e d b y

A p p ro v e d b y

R e v is io n s

U n it e d S ta te s D e p a rt m e n t o f th e

I n te ri o r

B u re a u o f L a n d M a n a g e m e n t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

KEY PLAN VIEW

/2

/2

:1

:3

A

M C

U s e rs

\a lf o n s o ra m ir e z \D o c u m e n ts

R e v it L o c a lT e m p \L

B Y

D B

L M

T O a rc h a lf o n s o ra m ir e z .r v t

F

IR

S T

F L

O O

R D

E M

O L

IT

IO

N R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N

K

E D

W A

R D

S

K

E D

W A

R D

S

A

R A

M

IR

E Z

S

R O

B E

R T

S

N

IF

C

-J W

H S

U

IT

E

U P

D A

T E

S D e v e lo p e m e n t

A v e

B o is e

ID

140L0622D0002

070117.020

05.23.2024

AD102

N A

T

IO

N A

L I

N T

E R

A G

E N

C Y

F

IR

E C

E N

T E

R

3 21

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

B1

FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN

1 REMOVE CEILING TILE. CEILING GRID TO REMAIN.

2 EXISTING SOUND INSULATION TO REMAIN, TYPICAL.

0 2' 4' 8'

N

SHEET KEYNOTES

REFLECTED CEILING DEMO LEGEND

D es cr ip tio n D at e

0%

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

5.

OPEN OFFICE

HALL

OFFICE

OFFICE

OFFICE

HUDDLE

OFFICE

OFFICE

HALL

E115.1

E111.1

ROOM NAME AND NUMBER

KEYNOTE

DOOR NUMBER (SEE SHEET A601)

DIMENSION TO FACE OF FRAMING

-1

NAME

X

A. VERIFY ALL CONDITIONS AND DIMENSIONS IN FIELD.

EXISTING CONDITIONS OF W INDOWS AND OTHER BUILDING

ELEMENTS MAY VARY. IF MEASUREMENTS IN FIELD

DEVIATE FROM THE DIMENSIONS SHOW N WITHIN THESE

DOCUMENTS BY GREATER THAN 6" OR AFFECT DESIGN

INTENT COORDINATE AND NOTIFY THE PROJECT

ARCHITECT PRIOR TO CONTINUING WORK.

B. FOR DOOR TYPES SEE SHEET A-601.

C. ALL DIMENSIONS ARE TO FACE OF STUD FOR GYPSUM

BOARD WALLS OR TO THE FACE OF EXISTING FINISH WALL

SURFACE, UNLESS OTHERWISE NOTED.

D. COORDINATE GOVERNMENT FURNISHED EQUIPMENT,

ACCESSORIES, AND FURNITURE WITH GOVERNMENT

AND/OR GOVERNMENT’S VENDOR.

1 2 3 4 5

D

C

B

A

S h e e t T it le

D e s ig n e d b y

D ra w n b y

C h e c k e d b y

A p p ro v e d b y

R e v is io n s

U n it e d S ta te s D e p a rt m e n t o f th e

I n te ri o r

B u re a u o f L a n d M a n a g e m e n t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

KEY PLAN VIEW

/2

/2

:1

:3

A

M C

U s e rs

\a lf o n s o ra m ir e z \D o c u m e n ts

R e v it L o c a lT e m p \L

B Y

D B

L M

T O a rc h a lf o n s o ra m ir e z .r v t

F

IR

S T

F L

O O

R P

L A

N

K

E D

W A

R D

S

K

E D

W A

R D

S

A

R A

M

IR

E Z

S

R O

B E

R T

S

N

IF

C

-J W

H S

U

IT

E

U P

D A

T E

S D e v e lo p e m e n t

A v e

B o is e

ID

140L0622D0002

070117.020

05.23.2024

A-101

N A

T

IO

N A

L I

N T

E R

A G

E N

C Y

F

IR

E C

E N

T E

R

4 21

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

B1

FIRST FLOOR PLAN

1 NEW ACCESS CONTROL SYSTEM, COORDINATE WITH

DOOR SCHEDULE AND ELECTRICAL DRAWINGS. PATCH,

REPAIR AND FINISH WALL AS REQUIRED FOR ELECTRICAL

WORK.

2 PREMANUFACTURED COLUMN WRAP AROUND EXISTING

ROOF DRAIN LINE. COLUMN BASIS-OF-DESIGN " 3-PLUS-1

COLUMN WRAP" AS MANUFACTURED BY AZEK EXTERIOR

OR EQUAL. COLUMN SIZE TO BE 8"X8"X10', PROVIDE TRIM

AT BASE AND TOP OF COLUMN. PAINT COLUMN, SEE

FINISH PLAN FOR PAINT INFORMATION.

3 PAINT EXISTING ROOF ACCESS LADDER SEE FINISH PLAN

FOR PAINT INFORMATION. DO NOT PAINT THE YELLOW

LADDER UP DEVICE.

4 TV MONITOR AND BLOCKING NOT IN CONTRACT. SEE

ELECTRICAL PLANS FOR ELECTRICAL AND DATA

COORDINATION.

5 OUTLINE OF FURNITURE/CUBICLE LAYOUT AND

EQUIPMENT NOT IN CONTRACT, TYPICAL.0 2' 4' 8'

N

SHEET KEYNOTES

PLAN LEGEND

GENERAL NOTES

D es cr ip tio n D at e

0%

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

5.

HALL

OPEN OFFICE

OFFICE

OFFICE

HALL

OFFICE

OFFICE

OFFICE

HUDDLE

AC1

8' - 6"

AC1

8' - 6"

AC1

8' - 6"

AC1

8' - 6"

EXIST

8' - 6"

CEILING MATERIAL

CEILING HEIGHT

ADDITIONAL NOTES

2X4 ACOUSTICAL

LAY-IN CEILING

GYPSUM BOARD

CEILING - PAINT

ACT

VARIES

NOTES

A. VERIFY ALL CONDITIONS AND DIMENSIONS IN FIELD.

EXISTING CONDITIONS OF W INDOWS AND OTHER BUILDING

ELEMENTS MAY VARY. IF MEASUREMENTS IN FIELD

DEVIATE FROM THE DIMENSIONS SHOW N WITHIN THESE

DOCUMENTS BY GREATER THAN 6" OR AFFECT DESIGN

INTENT COORDINATE AND NOTIFY THE PROJECT

ARCHITECT PRIOR TO CONTINUING WORK.

B. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION.

C. COORDINATE WITH THE MECHANICAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL ITEMS TO BE PROVIDED AT

THE CEILING PLANE.

D. ALL LIGHT FIXTURES AND SPRINKLER HEADS TO BE

CENTERED IN THEIR RESPECTIVE CEILING PANEL.

E. COORDINATE WITH THE MECHANICAL AND ELECTRICAL

DRAWINGS AND SPECIFICATIONS FOR THE LOCATION AND

PHYSICAL SIZES OF ALL CEILING GRILLS, DIFFUSERS,

FIXTURES, CANS, AND RELATED ITEMS.

1 2 3 4 5

D

C

B

A

S h e e t T it le

D e s ig n e d b y

D ra w n b y

C h e c k e d b y

A p p ro v e d b y

R e v is io n s

U n it e d S ta te s D e p a rt m e n t o f th e

I n te ri o r

B u re a u o f L a n d M a n a g e m e n t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

KEY PLAN VIEW

/2

/2

:1

:3

A

M C

U s e rs

\a lf o n s o ra m ir e z \D o c u m e n ts

R e v it L o c a lT e m p \L

B Y

D B

L M

T O a rc h a lf o n s o ra m ir e z .r v t

F

IR

S T

F L

O O

R R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N

K

E D

W A

R D

S

K

E D

W A

R D

S

A

R A

M

IR

E Z

S

R O

B E

R T

S

N

IF

C

-J W

H S

U

IT

E

U P

D A

T E

S D e v e lo p e m e n t

A v e

B o is e

ID

140L0622D0002

070117.020

05.23.2024

A-102

N A

T

IO

N A

L I

N T

E R

A G

E N

C Y

F

IR

E C

E N

T E

R

5 21

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

B1

FIRST FLOOR REFLECTED CEILING PLAN

1 CLEAN EXISTING GRID AS REQUIRED. NEW CEILING TILE

TO BE PLACED IN EXISTING GRID.

2 PATCH GYPSUM CEILING WHERE EXISTING FIXTURES AND

EQUIPMENT WERE REMOVED. CEILING TO BE PAINTED

PC1.

3 PREMANUFACTURED COLUMN WRAP, SEE FLOOR AND

FINISH PLAN FOR ADDITIONAL INFORMATION.

0 2' 4' 8'

N

SHEET KEYNOTES

REFLECTED CEILING LEGEND

GENERAL RCP NOTES

D es cr ip tio n D at e

0%

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

5.

HM HOLLOW METAL

T 1/4" TEMPERED GLAZING

WD SOLID CORE WOOD

PT# PAINT ( REFERENCE SPECIFICATION

SECTION 9 )

1. PAINT EXISTING HOLLOW METAL

DOOR FRAMES PER SPECIFICATION

SECTION 9.

2. EXISTING DOOR FRAME IS RATED.

MAINTAIN EXISTING FIRE RATING.

GROUP 1

-HINGES: PER SPECIFICATIONS,

ELECTRIC MIDDLE HINGE.

-LOCK: ELECTRIC MORTISE LOCK,

FAIL SECURE, LEVER.

-CLOSER: PER SPECIFICATIONS.

-SILENCERS: PER SPECIFICATIONS.

-SECURE CARD ACCESS J-BOX FOR ELECTRIFIED DOOR

HARDWARE FUNCTION.

GROUP 2

-LOCKSET (PASSAGE): PER SPECIFICATIONS.

-HINGES: PER SPECIFICATIONS.

-WALL STOP: PER SPECIFICATIONS.

-SILENCER: PER SPECIFICATIONS.

A. FIELD VERIFY ALL OPENING

DIMENSIONS PRIOR TO

FABRICATION/INSTALLATION.

B. SEE ELECTRICAL DRAWINGS FOR

ADDITIONAL REQUIREMENTS.

DOOR TYPES

S E

E S

C H

E D

U L E

SCHED

SEE

T

A

6" 8"

S E

E S

C H

E D

U L E

SCHED

SEE

B

INTERIOR

SEALANT

EXISTING WALL

EXISTING ALUMINUM

FRAMED WINDOW

SOLID SURFACE

WINDOW SILL, EASE

EDGE TO 1/8" RADIUS.

EXTERIOR

1/2"

/2

1 2 3 4 5

D

C

B

A

S h e e t T it le

D e s ig n e d b y

D ra w n b y

C h e c k e d b y

A p p ro v e d b y

R e v is io n s

U n it e d S ta te s D e p a rt m e n t o f th e

I n te ri o r

B u re a u o f L a n d M a n a g e m e n t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

:1

:3

A

M C

U s e rs

\a lf o n s o ra m ir e z \D o c u m e n ts

R e v it L o c a lT e m p \L

B Y

D B

L M

T O a rc h a lf o n s o ra m ir e z .r v t

S C

H E

D U

L E

S A

N D

D E

T A

IL

S

K

E D

W A

R D

S

K

E D

W A

R D

S

A

R A

M

IR

E Z

S

R O

B E

R T

S

N

IF

C

-J W

H S

U

IT

E

U P

D A

T E

S D e v e lo p e m e n t

A v e

B o is e

ID

140L0622D0002

070117.020

05.23.2024

A-601

N A

T

IO

N A

L I

N T

E R

A G

E N

C Y

F

IR

E C

E N

T E

R

6 21

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

DOOR, FRAME AND HARDWARE SCHEDULE

DOOR

NUMBER

ROOM

NUMBER

ROOM

NAME

DOOR FRAME

FIRE

RATING HARDWARE

GROUP NOTES

SIZE

MTL TYPE GLAZE MTL TYPE

W H T

E111.1 111 HUDDLE 3' - 0" 7' - 0" 0' - 1 3/4" WD A T HM EXST -- 2 1

E115.1 115 OPEN

OFFICE

3' - 0" 7' - 0" 0' - 1 3/4" WD B - HM EXST 20 MIN 1 1,2

MATERIALS LIST

ITEM

NO PRODUCT TYPE MANUFACTURER DESCRIPTION COLOR SIZE NOTES

BASE

RB1 RESILENT BASE ROPPE PINNACLE RUBBER COVED WALL

BASE

DARK BROWN 4" H

CEILING

AC1 ACOUSTIC CEILING ARMSTRONG FINE FISSURED SECOND LOOK WHITE 24" X 48" NEW TILE IN EXISTING GRID

FLOOR

CP1 CARPET J+J FLOORING KINETEX PUT A CORK IN IT 2197 DRUM 24" X 24" FOR ACCESS FLOORING - USE KINETEX PREFIX ADHESIVE (PEEL & STICK). IN

ALL NON-ACCESS FLOORING AREA USE STANDARD KINETEX ADHESIVE PER

MANUFACTURER INSTRUCTION.

MILLWORK

SS2 SOLID SURFACE CORIAN BONE WINDOW SILL ONLY.

TRANSITIONS

TR1 TRANSITION PROFILE ROPPE ADAPTOR/TRANSITION LIGHT BROWN EXISTING CARPET TO NEW

WALL

P1 PAINT SHERWIN WILLIAMS GENERAL WALL PAINT PACER WHITE SW

LOW VOC. SATIN FINISH

P2 PAINT SHERWIN WILLIAMS TRIM PAINT DARK CLOVE SW 9183 SEMI GLOSS FINISH. DIRECT TO METAL PAINT - MATCH STANDARD PAINT TYPE

USED THROUGHOUT BUILDING.

P3 PAINT SHERWIN WILLIAMS ACCENT WALL PAINT AMAZING GRAY SW

LOW VOC. SATIN FINISH

P5 PAINT SHERWIN WILLIAMS ACCENT WALL PAINT STARDEW SW 9138 LOW VOC. SATIN FINISH

C3

SOLID SURFACE W INDOW SILL

GENERAL NOTES

ABBREVIATIONS

DOOR NOTES

DOOR HARDW ARE

D es cr ip tio n D at e

0%

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

5.

OPEN OFFICE

OFFICE

OFFICE

OFFICE

HUDDLE

HALL

OFFICE

OFFICE

HALL

RB1

P1

CP1

P5

P

RB1

P1

CP1

RB1

P1

CP1

RB1

P1

CP1

RB1

P1

CP1

1 1 1

V.I.F

31' - 4"

V .I

.F

P3 P3 P3

4 4 4

EXTENT OF ACCENT PAINT OR WALL FINISHES

ROOM NAME AND NUMBER

FLOOR FINISH 'CP1'

FINISH TAG

NAME

FINISH TAGS DISPLAYED IN GROUPING ON FINISH PLAN

REPRESENT MAJORITY ROOM FINISH SELECTIONS. ORDER

OF GROUPING DEFINED IN EXAMPLE BELOW:

MAJORITY WALL FINISH

MAJORITY BASE FINISH

MAJORITY FLOOR FINISH

XX###

XX###

XX###

XX###

XX###

1 2 3 4 5

D

C

B

A

S h e e t T it le

D e s ig n e d b y

D ra w n b y

C h e c k e d b y

A p p ro v e d b y

R e v is io n s

U n it e d S ta te s D e p a rt m e n t o f th e

I n te ri o r

B u re a u o f L a n d M a n a g e m e n t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

KEY PLAN VIEW

/2

/2

:1

:3

A

M C

U s e rs

\a lf o n s o ra m ir e z \D o c u m e n ts

R e v it L o c a lT e m p \L

B Y

D B

L M

T O a rc h a lf o n s o ra m ir e z .r v t

F

IN

IS

H

F L

O O

R P

L A

N

K

E D

W A

R D

S

K

E D

W A

R D

S

A

R A

M

IR

E Z

S

R O

B E

R T

S

N

IF

C

-J W

H S

U

IT

E

U P

D A

T E

S D e v e lo p e m e n t

A v e

B o is e

ID

140L0622D0002

070117.020

05.23.2024

I-101

N A

T

IO

N A

L I

N T

E R

A G

E N

C Y

F

IR

E C

E N

T E

R

7 21

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

B1

FIRST FLOOR FINISH PLAN

1 SOLID SURFACE WINDOW SILL.

2 PAINT PREFAB COLUMN P5 TO MATCH ADJACENT WALL

3 LADDER TO BE PAINTED P1.

4 PATCH WALLS WHERE DEMO AS OCCURED TO CREATE

SMOOTH FINISH FOR NEW PAINT TO BE APPLIED. ALL

WALLS TO BE PAINTED WITHIN ROOM INDICATED.

5 EXISTING GYPSUM BOARD COLUMN ENCLOSURE,

PAINT P3.

0 2' 4' 8'

N

SHEET KEYNOTES

FINISH PLAN LEGEND

D es cr ip tio n D at e

0%

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

5.

P R O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:18-06'00'

O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:24-06'00'

O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:28-06'00'

O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:31-06'00'

O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:34-06'00'

O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:38-06'00'

O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:41-06'00'

O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:44-06'00'

O

FE

SS

IONAL ENGINEER

NATHAN J. FRON

GN

ER

STATE OF IDA

HO

L I C E N S E D

18674

Digitally signed by Nathan Frongner, P.E.

13:05:05-06'00'

PR

OFESS IONAL ENG INEER

D A R R E L L D E A

N

L

I C E N S E D

STA T E OF I DA HO

19543 darrell dean 2024.05.24

08:08:32-04'00'

D A R R E L L D E A

N

L

I C E N S E D

STA T E OF I DA HO

19543

08:08:32-04'00'

D A R R E L L D E A

N

L

I C E N S E D

STA T E OF I DA HO

19543

08:08:33-04'00'

D A R R E L L D E A

N

L

I C E N S E D

STA T E OF I DA HO

19543

08:08:34-04'00'

D A R R E L L D E A

N

L

I C E N S E D

STA T E OF I DA HO

19543

08:08:34-04'00'

File details come from the government source that posted it. Updated .