This document package includes construction drawings and specifications for a federal solicitation seeking egress doors and steel racks. The National Interagency Fire Center is soliciting bids to install new sidewalk, egress doors, and infill steel stud walls at Building 215GBK to match finish floor elevations and provide ADA accessibility. Drawings depict the work area, demolition plans, concrete details and mounting heights for devices. Specifications identify general contractor responsibilities for coordination, slopes, materials and reinforcements. The solicitation number is 140L3723R0009 and was issued by the Bureau of Land Management Idaho Region. Offerors should reference all provided documents and details in preparing proposals for the required construction work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STOPSTOP

BOLLARD

MCP

MCP

Vehicle Mail

0 5' 10'

PLAN

NORTH

SITE PLANA2

1. COORDINATE ANY UTILITY OUTAGES WITH THE GOVERNMENT.

GENERAL SHEET NOTES

1. SAWCUT AND REMOVE CURB AND GUTTER TO MAKE WAY FOR

NEW SIDEWALK.

2. AVOID PLACING SIDEWALK OVER ABANDONED SANITARY SEWER

VAULT.

SHEET KEY NOTES

KEY PLAN

215-GBK

AREA OF WORK

215-GBK

FF: 2862.90 FT

Ben L Carter, P.E.

Digitally signed by Ben L Carter, P.E.

Date: 2023.04.17 18:15:17 -06'00'

0 5' 10'

PLAN

NORTH

SITE PLANA2

1. COORDINATE ANY UTILITY OUTAGES WITH THE GOVERNMENT.

2. SIDEWALK LANDING SHALL HAVE A MAXIMUM SLOPE OF 2% IN ANY

DIRECTION.

GENERAL SHEET NOTES

1. PROVIDE AND INSTALL NEW SIDEWALK PER DETAIL 1 SHEET C501.

MATCH FINISH FLOOR ELEVATION AT DOORWAY.

2. PROVIDE AND INSTALL SIDEWALK TO GRADUALLY DESCEND AND

MATCH EXISTING SURFACE ELEVATION AT END OF SIDEWALK.

SHEET KEY NOTES

KEY PLAN

215-GBK

AREA OF WORK

215-GBK

FF: 2862.90 FT

5.00'

7.00'

13.59'

EXISTING TRASH

COMPACTOR

EL = ~2862.5'

Ben L Carter, P.E.

Digitally signed by Ben L Carter, P.E.

Date: 2023.04.17 18:16:31

SCALE: NTS

TYPICAL CONCRETE SLAB1

4" CONCRETE

REINFORCED WITH 10GA MESH

AT 4" OC OR #3 BAR AT 18" OC

4" BASE COURSE

FIRM NATIVE SOILS OR

ENGINEERED COMPACTED FILL

PROVIDE THICKENED EDGE

ALONG BOTH SIDES AND

ENDS OF WALK

8"

4' - 10'

AS SHOWN ON PLAN

MATCH EXISTING GRADE AT

END OF SIDEWALK

Ben L Carter, P.E.

Digitally signed by Ben L Carter, P.E.

Date: 2023.04.17 18:18:12

1'-51 2" V.I.F.

3'-4"

6'-8" V.I.F.3'-4"

1' -4

" V .I.

F.

3'

-4

3'-4"

8" V.I.F.

8'-0"

1" M

IN

1/ 2"

04/17/23

DETAIL NOTES

1 NEW DOOR OPENING IN EXISTING WALL

S501

2 NEW DOOR OPENING LINTEL ANGLE

S501

2 STEEL SECTION IDENTIFICATION

S502

DETAIL NOTES

1 NEW STUD WALL INFILL FOR NEW DOORS AT (E) OPENING

S502

3 TYPICAL BOX HEADER

S502

4 BOXED HEADER TO JAMB CONNECTION

S502

6 STEEL STUD BRIDGING DETAIL

S502

5 TYPICAL JAMB DETAIL

S502

LV

J

1' -6

" 1' -6

" M

IN

. I N

H

AZ

AR

D

O U

S

LO

C

AT

IO

N

S-

TO

B O

TT

O

M O

F C

AN 74

" T

O T

O P

O F

TR

IM

FINISHED CEILING

AC = ABOVE COUNTER, MINIMUM 4"

ABOVE BACKSPLASH TO

BOTTOM OF DEVICE

PANEL

BOARD

C S

F

INTERIOR BOX MOUNTING HEIGHTS

" A

FF

T

O B

O

TT

O M

O F

D

EV

IC

E

O R

" B

EL

O

W C

EI

LI

N G

T O

T O

P O

F D

EV

IC

E W

H

IC

H

EV

ER

IS

L O

W

ER

F

BOD

" M

IN

IM

U M

T O

B O

TT

O

M O

F D

EV

IC

E

FIRE FIRE

F

M O

U N

T 4"

A

BO

VE

D

O O

R F

R

AM

E

FIRE

S D

KP T CO2

48" TOD IS ACCEPTABLE FOR

CMU BLOCK CONSTRUCTION

F

BOD

BOD

BOD

BOD

FINISHED FLOOR

BATTERY

BACKUP

TO01_P2_G101
C101
C102
C501
TO01_P2_A012
TO01_P2_A013
TO01_P2_A014
TO01_P2_A112
TO01_P2_A113
TO01_P2_A114
TO01_P2_A115
TO01_P2_A116
S001_GENERAL STRUCTURAL NOTES
S501_CMU WALL OPENING STRUCTURAL DETAILS
S502_STRUCTURAL WALL INFILL DETAILS
TO01_P2_E001
TO01_P2_E002
TO01_P2_E121
TO01_P2_E122
TO01_P2_E123
TO01_P2_E124