A06_Drawings.pdf
PDF 4 MB Posted
- Attached to
- UPGRADE ELECTRICAL SERVICE AT FVC Federal contract opportunity
- Solicitation number
- 140P4325R0037
About this file
These architectural and engineering drawings detail an electrical distribution upgrade project for the Fredericksburg & Spotsylvania National Military Park's Headquarters and Visitor Center located in Fredericksburg, Virginia. The comprehensive set of eight drawing sheets covers electrical system modifications across multiple building floors, including removals, revisions, and new electrical panel installations. Key elements include replacing existing electrical panels (Panels 1, 2, B, and B1) with new panels, installing a new Main Distribution Panel (MDP), upgrading feeders and branch circuits, and modifying electrical infrastructure while preserving the historic integrity of the facility. The project involves careful electrical system reconfiguration across ground, first, and second floors, with specific attention to maintaining operational continuity and minimizing disruption to the historic site's functionality.
The drawings provide detailed specifications for electrical work, including removing existing equipment, installing new panels with 120/208V configurations, upgrading conduit and wiring, and implementing new grounding systems. The technical documentation includes floor plans, panel schedules, riser diagrams, and phased removal and installation notes. Specific requirements include preserving historic fabric, using existing routing for new feeders where possible, and coordinating all modifications with the Contracting Officer's Representative (COR). The project scope encompasses electrical distribution upgrades, panel replacements, feeder modifications, and comprehensive electrical system improvements while maintaining the historic character of the National Military Park facility.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P4325R0037.pdf | ||
| A04_Statement_of_Work.pdf | ||
| B03_Wage_Determination_VA20240165_28_February_2025.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FREDERICKSBURG & SPOTSYLVANIA
NATIONAL MILITARY PARK
ELECTRICAL DISTRIBUTION UPGRADES
FREDERICKSBURG CITY
VIRGINIA
SHEET SUB TITLE
NO. SHEET
1 CS COVER SHEET
2 E.001 GENERAL NOTES & DETAILS
3 E.101 REMOVALS FLOOR PLANS - DISTRIBUTION SYSTEM
4 E.102 REVISIONS FLOOR PLANS - DISTRIBUTION SYSTEM
5 E.103 PART FLOOR PLANS - UTILITY ROOM
6 E.201 UTILITY ROOM ELEVATIONS - REMOVALS & REVISIONS
7 E.301 SCHEDULE OF PANEL MDP & 1-LINE RISER DIAGRAM
8 E.302 SCHEDULES OF DISTRIBUTION PANELS
C:
\U se rs
\r to rp ey
\O ne
D riv e
- D
O I\0
PR
O
JE
CT
S\
FR
SP
\F
RS
P
PM
IS
-2
- F
VC
E
LE
CT
RI
CA
L
UP
GR
AD
E\
D
RA
W
IN
GS
\0
FR
SP
Co ve r S he et
-1 .d w g, L ay ou t3
, 2 /4
/2
1:
:0
PM
1. DRAWINGS ARE CONCEPTUAL AND ARE INTENDED TO SHOW GENERAL SYSTEM
CONFIGURATION AND PERFORMANCE. NOT ALL NECESSARY DEVICES AND
COMPONENTS ARE SHOWN. PROVIDE ALL DEVICES AND COMPONENTS FOR A
FULLY FUNCTIONAL SYSTEM.
2. INSTALL DEVICES AND SYSTEM WIRING TO AVOID DISTURBANCE TO HISTORIC
FABRIC AND TO AVOID VISUAL INTRUSION INTO PUBLIC VISITATION AREAS.
HISTORIC PRESERVATION SHALL BE TAKEN INTO ACCOUNT THROUGHOUT THE
PROJECT.
3. USE EXISTING ROUTING FOR NEW FEEDERS AND BRANCH CIRCUITS
WHENEVER POSSIBLE. IF A PATH IS FOUND TO BE UNTENABLE, CONFIRM NEW
ROUTING WITH THE COR. WIRING SHALL BE INSTALLED WITHIN CONDUIT
WHERE EXISTING PATHS INCLUDE CONDUIT.
4. USE EXISTING HOLES AND OPENINGS TO INSTALL CONDUIT AND CABLE. WHERE
NO USABLE PATH EXISTS, CUT NEW HOLES. COORDINATE SIZE AND LOCATIONS
OF DRILLED HOLES AND CUT OPENINGS WITH THE COR.
5. IT IS RECOMMENDED THAT THE CONTRACTOR VISIT AND BECOME FAMILIAR
WITH THE SITE PRIOR TO SUBMITTING BID.
6. EXISTING SERVICE SHALL REMAIN ON-LINE DURING THE WORK.
7. CONTRACT DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND MUST
BE USED IN CONJUNCTION TO OBTAIN COMPLETE CONSTRUCTION
INFORMATION. CONTRACTOR SHALL COORDINATE ALL DRAWINGS AND
SPECIFICATIONS PRIOR TO COMMENCING WORK. QUESTIONS REGARDING
DESIGN INTENT OR SYSTEM OPERATION SHALL BE PROMPTLY BROUGHT TO
ATTENTION OF THE COR.
8. THE TERM "REMOVE" MEANS DISCONNECT AND REMOVE THE DEVICE
INCLUDING OUTLET AND BRANCH CIRCUIT WIRING AND RACEWAY.
9. THE TERM “PROVIDE” MEANS FURNISH AND INSTALL, COMPLETE AND READY
FOR USE.
10. THE TERM “CONTRACT DOCUMENTS” MEANS THE PROJECT MANUAL,
DRAWINGS, ADDENDUMS, SKETCHES AND OTHER DOCUMENTATION THAT
DEFINE THE WORK.
11. ANY CONFLICTS BETWEEN SPECIFICATIONS AND DRAWINGS SHALL BE
PROMPTLY BROUGHT TO COR’S ATTENTION. THE CONTRACTOR SHALL NOT
PROCEED WITH ANY WORK EXCEPT AT THEIR OWN RISK, UNTIL
CLARIFICATIONS OF CONFLICTS ARE ISSUED TO THE CONTRACTORS BY THE
COR.
12. WHERE DEVICES, WIRING, MOLDING, ETC. ARE TO BE REMOVED FROM EXISTING
HISTORIC FABRIC AND REMOVAL MAY NOT BE POSSIBLE WITHOUT DAMAGING
EXISTING HISTORIC FABRIC, NOTIFY COR PRIOR TO THE REMOVAL OF THE ITEM.
13. PROVIDE ENGRAVED, PHENOLIC NAMEPLATE PANELS, SAFETY SWITCHES,
CABINETS, ETC, TO IDENTIFY THE UNIT AND THE SOURCE PANEL AND CIRCUIT
NUMBER.
14. ALL ELECTRICAL MATERIALS SHALL BE TEMPERATURE RATED FOR 90°C.
GENERAL NOTES
GFCI DUPLEX RECEPTACLE IN SURFACE BELL BOX WITH IN-USE
WEATHERPROOF COVER. MOUNTED 18" A.F.F. UNLESS NOTED OTHERWISE.
SAFETY DISCONNECT SWITCH MOUNTED AT UNIT.
JUNCTION BOX, SURFACE, WALL MOUNTED 18" A.F.F. WITH BLANK COVER.
NEW WIRING IN CONDUIT (SOLID, BOLD): 2-#12 & 1-#12G - 3/4"C, UNLESS
NOTED OTHERWISE.
EXISTING WIRING (SOLID, LIGHT) TO REMAIN.
EXISTING WIRING (DASHED) TO BE REMOVED.
D
GF
SYMBOLS LIST
J
HALLWAY
CLOSET
FILE RM
(BLANK)
(BLANK)
A/C ADMIN
A/C SECRT
A/C UNITS
LIGHTS ADMIN
LIGHTS SECY
LIGHTS SUPRV
(BLANK)
A/C FILE ROOM
A/C CO SUPRV
A/C UNITS
TO
N
EW
PA
N
EL
P
GROUND BAR
DETAIL TERMINAL CABINET, 2ND FLOOR
BRANCH CIRCUIT WIRING FROM
REMOTE EQUIPMENT & DEVICES.
EXISTING RECESSED CABINET
BRANCH CIRCUIT WIRING FROM
REMOTE EQUIPMENT & DEVICES.
LIGHTS #1
GROUND BAR
DETAIL : SWITCHES AT PANEL P "1"
a
LIGHTS #2b
LIGHTS #3c
LIGHTS #4d
LIGHTS #5e
GENERAL NOTES AND DETAILS
E-001
ELECTRICAL DISTRIBUTION UPGRADES AT FVC
FREDERICKSBURG & SPOTSYLVANIA NMP
1013 LAFAYETTE BLVD, FREDERICKSBURG, VA 22401
C:
\U se rs
\r to rp ey
\O ne
D riv e
- D
O I\0
PR
O
JE
CT
S\
FR
SP
\F
RS
P
PM
IS
-2
- F
VC
E
LE
CT
RI
CA
L
UP
GR
AD
E\
D
RA
W
IN
GS
\0
2-
D
IS
TR
IB
UT
IO
N
F
LO
O R
PL
AN
S.
dw g, GE
N
ER
AL
, 2
/4 /2
1:
:4
FIRST FLOOR PLAN
UP TO SECOND FL
HALL
EXHIBIT
WEST
EXHIBIT
EAST
OFFICE
EXHIBIT
NORTH
STAFF
EXISTING PANEL 1,
120/240V, 1Ø, 100A
FC
U
-6
FC
U
-7
FC
U
-8
FCU-8
SECOND FLOOR PLAN
ATTIC
WEST
ATTIC
EAST
OFFICE
OFFICE
OFFICE
OFFICE
HALL
STAIR
EXISTING PANEL 2,
120/240V, 1Ø, 100A
CLOSET
201A
CLOSET
202A
CLOSET
203A
CLOSET
204A
UP UP
UP
FCU #1
FCU #1
FU
R
N
AC
E
10 PNL
B
EXISTING MAIN SERVICE
CIRCUIT BREAKER: 400A, 3P.
WH
WC
GROUND FLOOR PLAN
UP TO PANEL 1,
FIRST FLOOR.
EXISTING UTILITY
TRANSFORMER
208/120V, 3Ø
EU
G
E
EX
T'
G C
H
IL
LE
R
8V
, 3 Ø
EXHIBIT WEST
B06
STORAGE
B05
EXHIBIT EAST
B03
WOMEN'S
ROMM
B02
MEN'S
ROOM
B07
STAIR
HALL
B00
WOMEN'S
VESTIBULE
B01
MEN'S
VESTIBULE
B07
CLOSET
B09
EXISTING UTILITY
TRANSFORMER
240/120V, 1Ø
EXISTING PANEL B,
120/240V, 1Ø, 100A
LT
SHEET NOTES:
1. SEE SHEET 8 FOR ELECTRICAL REMOVALS IN THIS AREA.
2. EXISTING SERVICE FEEDER RUN ON WALL TO BE REMOVED.
3. REMOVE SERVICE FEEDER WIREWAY AND PLUG ABANDON
CONDUIT.
4. ABANDON UNDERGROUND CONDUIT AFTER REMOVAL OF
CONDUCTORS.
5. EXISTING UTILITY TRANSFORMER TO REMAIN. COORDINATE
REMOVAL OF SECONDARY CONDUCTORS WITH THE ELECTRIC
COMPANY.
6. REMOVE CONDUIT & WIRING TO EXISTING CHILLER.
7. REMOVE CONDUCTORS FROM PANEL MDP TO PANEL 1, FIRST
FLOOR. RETAIN CONCEALED CONDUIT FOR RE-USE.
8. REMOVE FEEDER TO PANEL B, BASEMENT & FEEDER TO
PANEL 2, SECOND FLOOR.
9. DISCONNECT BRANCH CIRCUITS FROM PANEL 2 AND RETAIN.
REMOVE EXISTING SURFACE MOUNTED PANEL B.
10. REMOVE FEEDERS TO PANEL 2 VIA FIRST FLOOR.
11. DISCONNECT BRANCH CIRCUITS FROM PANEL AND RETAIN.
REMOVE EXISTING PANEL 1, RECESSED MOUNTED.
12. REMOVE FEEDER TO PANEL 2.
13. DISCONNECT BRANCH CIRCUITS FROM PANEL 2 AND RETAIN.
REMOVE PANEL 2, SURFACE MOUNTED WITHIN LARGER,
RECESSED MOUNTED PANEL BACK BOX.
REMOVALS FLOOR PLANS
ELECTRICAL DISTRIBUTION
E-101
SCALE: 3/16" = 1'-0"
2'0 6' 10' 14' 22'
ELECTRICAL DISTRIBUTION UPGRADES AT FVC
FREDERICKSBURG & SPOTSYLVANIA NMP
1013 LAFAYETTE BLVD, FREDERICKSBURG, VA 22401
C:
\U se rs
\r to rp ey
\O ne
D riv e
- D
O I\0
PR
O
JE
CT
S\
FR
SP
\F
RS
P
PM
IS
-2
- F
VC
E
LE
CT
RI
CA
L
UP
GR
AD
E\
D
RA
W
IN
GS
\0
2-
D
IS
TR
IB
UT
IO
N
F
LO
O R
PL
AN
S.
dw g, D
EM
O
P
LA
N S, /4
/2
1:
:1
SaSbScSdSe
UP TO SECOND FL
HALL
EXHIBIT
WEST
EXHIBIT
EAST
OFFICE
EXHIBIT
NORTH
STAFF
FIRST FLOOR PLAN
FC
U
-6
FC
U
-7
FC
U
-8
FCU-8
NEW PANEL P2:
120/208V, 1Ø, 100A
3-#4 & 1-#6G - 1"C
ATTIC
WEST
ATTIC
EAST
OFFICE
OFFICE
OFFICE
OFFICE
HALL
STAIR
SECOND FLOOR PLAN
CLOSET
201A
CLOSET
202A
CLOSET
203A
CLOSET
204A
UP UP
UP
FCU #1
FCU #1
FU
R
N
AC
E
EXISTING MAIN SERVICE
CIRCUIT BREAKER: 400A, 3P.
3-#3 & 1-#8G - 1-1/4"C. UP
TO PANEL 1, FIRST FL.
3-#3 & 1-#8G - 1-1/4"C.
TO PANEL MDP
WH
WC
UTILITY ROOM
B04
SEE SHEET 5
EXISTING UTILITY
TRANSFORMER
208/120V, 3Ø
EU
G
E
EX
T'
G C
H
IL
LE
R
8V
, 3 Ø
PNL
B
EXHIBIT WEST
B06
STORAGE
B05
EXHIBIT EAST
B03
WOMEN'S
ROMM
B02
MEN'S
ROOM
B07
STAIR
HALL
B00
WOMEN'S
VESTIBULE
B01
MEN'S
VESTIBULE
B07
CLOSET
B09
3-# & 1-#8G - 1-1/4"C
TO EXISTING CHILLER.
3-#3 & 1-#8G - 1-1/4"C.
TO PANEL MDP
NEW PANEL MDP:
120/208V, 3Ø, 400A.
3-#3 & 1-#8G - 1-1/4"C
CONCEALED
NEW PANEL 'B':
120/240V, 1Ø
LT
GROUND FLOOR PLAN
4-600KCMIL & 1-#3, FEEDER FROM
EXISTING MAIN SEVICE CB TO NEW
PANEL MDP.CONDUITS RUN IN SPACE
BEHIND EXHIBITS
CONDUIT RUN IN SPACE
BEHIND EXHIBITS
SHEET NOTES:
1. RUN NEW CONDUIT TO EXISTING CONDUIT THAT IS
CONCEALED IN THE FLOOR AND WALL, UP TO PANEL
"1", FIRST FLOOR. RUN NEW CONDUCTORS THROUGH
NEW AND EXISTING CONDUITS.
2. FURNISH AND INSTALL NEW PANEL "B" IN SAME
LOCATION AS THE REMOVED PANEL. CONNECT
EXISTING BRANCH CIRCUITS TO CIRCUIT BREAKERS
MATCHING THE CHARACTERISTICS OF THE REMOVED
CIRCUIT BREAKERS. SEE SCHEDULE ON SHEET 7.
3. RUN NEW CONDUIT ALONG THE SAME ROUTE AS THE
REMOVED CONDUIT AND UTILIZE THE SAME
PENETRATIONS. FIRE SEAL ALL PENETRATIONS.
4. FURNISH AND INSTALL NEW PANEL "1" IN SAME
LOCATION AS THE REMOVED PANEL. CONNECT
EXISTING BRANCH CIRCUITS TO CIRCUIT BREAKERS
MATCHING THE CHARACTERISTICS OF THE REMOVED
CIRCUIT BREAKERS. SEE SCHEDULE ON SHEET 7.
5. FURNISH AND INSTALL NEW LIGHTING CIRCUIT
SWITCHES IN, ONE 5-GANG RECESSED SWITCH BOX
WITH SINGLE FACE PLATE.
6. RUN NEW FEEDER ALONG SAME ROUTE AS REMOVED
CONDUIT INTO CLOSED. THEN RUN HIGH ON THE
BACK WALL OF THE CLOSET, TURN THROUGH THE
WALL INTO THE ADJACENT CLOSET AND TO PANEL "2".
7. FURNISH AND INSTALL NEW TERMINAL STRIP IN
RECESSED CABINET: SEE WIRING DIAGRAM ON SHEET
2. PROVIDE A NEW, HINGED COVER FOR THE EXISTING
RECESSED CABINET.
8. FURNISH AND INSTALL NEW PANEL "2" ON WALL IN
HALL 200. CONNECT EXISTING BRANCH CIRCUITS,
FROM NEW TERMINAL STRIP, TO CIRCUIT BREAKERS
MATCHING THE CHARACTERISTICS OF THE REMOVED
CIRCUIT BREAKERS IN REMOVED PANEL "2". SEE
SCHEDULE ON SHEET 7.
9. FURNISH AND INSTALL NEW CABINET ENCLOSING
NEW PANEL "2". CABINET DOOR DIMENSION SHALL BE
THE FULL HEIGHT AND WIDTH OF PANEL "2" PLUS 1/2"
PER SIDE, TOP AND BOTTOM.
FLOOR PLANS
ELECTRICAL DISTRIBUTION
E.102
SCALE: 3/16" = 1'-0"
2'0 6' 10' 14' 22'
ELECTRICAL DISTRIBUTION UPGRADES AT FVC
FREDERICKSBURG & SPOTSYLVANIA NMP
1013 LAFAYETTE BLVD, FREDERICKSBURG, VA 22401
C:
\U se rs
\r to rp ey
\O ne
D riv e
- D
O I\0
PR
O
JE
CT
S\
FR
SP
\F
RS
P
PM
IS
-2
- F
VC
E
LE
CT
RI
CA
L
UP
GR
AD
E\
D
RA
W
IN
GS
\0
2-
D
IS
TR
IB
UT
IO
N
F
LO
O R
PL
AN
S.
dw g, RE
VI
SI
O N
S
PL
AN
S, /4
/2
1:
:4
FCU #1
FCU #1
FU
R
N
AC
E
UTILITY ROOM FLOOR PLAN:
REMOVALS
WH
SP
PANEL B1 TO
BE REMOVED
DISC SW TO
BE REMOVED.
FUSE PANEL TO
BE REMOVED.
PHASE CONVERTER
#1 TO BE REMOVED.
MAIN SVC SW TO
BE REMOVED.
PH CONV MOTOR 1 DISC
SW TO BE REMOVED.
SUMP PIT
ABANDONED DISC SW
TO BE REMOVED.
CHILLER DISC SW
TO BE REMOVED.
PANEL CH2 TO
BE REMOVED.
PANEL CH1 TO
BE REMOVED.
FAC
P
SAC
P
WH
FURNACE PANEL
TO REMAIN.
MDP
B1
B1
EXISTING FIRE ALARM
CONTROL PANEL
EXISTING SECURITY
ALARM CONTROL PANEL
UTILITY
ROOM
PC2
PC1
STORAGE
EXHIBIT EAST
B03
HALL
B00
CLOSET
D
ER
D
ER
WATER DRINKING
FOUNTAIN.
LT
UP UP
UP
WH
FCU #1
FCU #1
FU
R
N
AC
E5 3-#4 & 1-#8G - 1"C.
MDP
WH
SP
WATER DRINKING
FOUNTAIN.
UTILITY ROOM FLOOR PLAN:
REVISIONS
2-#10 & 1-#12G - 3/4"C.
MDP
J
B1 B1
FAC
P
SAC
P
B1
B1
WP
GF
UTILITY
ROOM
STORAGE
EXHIBIT EAST
B03
HALL
B00
CLOSET
D X
D X
B1
B1
NEW PANEL MDP: 120/208V,
3Ø, 400A. SEE SCHEDULE
ON SHEET 6.
MDP
B1 wp
GF
2-#- & 1-#-G - -"C.
2-#- & 1-#-G - -"C.
LT
FURNACE PANEL
TO REMAIN.
NEW PANEL "B1": 120/240V, 1Ø.
SEE SCHEDULE ON SHEET 6.
B1
10 8
WP
GF
SHEET NOTES:
1. SEE SHEET 8 FOR ELECTRICAL WORK IN THIS AREA.
2. REMOVE EXISTING PHASE CONVERTER #1 AND WIRING BACK TO CONTROLLER #1.
3. REMOVE EXISTING PHASE CONVERTER #2 AND CONTROLLER #2 INCLUDING WIRING
BACK TO CONTROLLER #1.
4. REMOVE DUPLEX RECEPTACLE SURFACE MOUNTED ON THE FLOOR. FILL AND LEVEL
FLOOR.
5. EXISTING FURNACE ELECTRICAL PANEL TO REMAIN. REMOVE FEEDER BACK TO
SOURCE.
6. EXISTING PANEL B1 TO BE REMOVED INCLUDING FEEDER. REMOVE BRANCH CIRCUITS
TO WATER HEATER, CEILING LIGHT, WATER COOLER AND WALL MOUNTED
RECEPTACLE.
7. REMOVE WIRING FROM EXISTING CEILING LIGHT TO PANEL B1. RETAIN CONCEALED
CONDUIT.
8. REMOVE BRANCH CIRCUITS TO FCU #1 & #2. RETAIN DISCONNECT SWITCH AND
LOAD-SIDE WIRING TO UNIT.
9. NEW DUPLEX GFCI 20A, RECEPTACLE IN WEATHER PROOF OUTLET WITH IN-USE
WEATHER-PROOF COVER. RECEPTACLE AT SUMP PIT MOUNTED HIGH ON THE WALL.
10. TRENCH CONCRETE FLOOR AND PROVIDE RGC FROM NEW PANEL B1 TO NEW
RECEPTACLE MOUNTED ON SUMP PIT WALL. FILL TRENCH WITH APPROVED CONCRETE
PATCHING MATERIAL.
11. PROVIDE NEW BRANCH CIRCUIT TO EXISTING WATER HEATER.
12. PROVIDE NEW BRANCH CIRCUIT TO EXISTING WATER COOLER THROUGH NEW WALL
MOUNTED JUNCTION BOX. UTILIZE EXISTING WALL PENETRATION.
13. PROVIDE NEW BRANCH CIRCUITS TO EXISTING FIRE ALARM CONTROL PANEL (FACP)
AND EXISTING SECURITY ALARM CONTROL PANEL (SACP) FROM INDIVIDUAL,
DEDICATED BRANCH BREAKERS. BRANCH CIRCUIT FOR THE FACP SHALL BE RED AND
LOCKABLE.
14. PROVIDE NEW BRANCH CIRCUITS TO EXISTING FCU #1 & FCU #2 TO EXISTING
DISCONNECT SWITCH AT RESPECTIVE UNIT FROM INDIVIDUAL. DEDICATED BRANCH
BREAKERS.
PART FLOOR PLANS
UTILITY ROOM
E.103
KEY PLAN: GROUND FLOOR
SCALE: 3/8" = 1'-0"
1'0 3' 5' 7' 11'
ELECTRICAL DISTRIBUTION UPGRADES AT FVC
FREDERICKSBURG & SPOTSYLVANIA NMP
1013 LAFAYETTE BLVD, FREDERICKSBURG, VA 22401
C:
\U se rs
\r to rp ey
\O ne
D riv e
- D
O I\0
PR
O
JE
CT
S\
FR
SP
\F
RS
P
PM
IS
-2
- F
VC
E
LE
CT
RI
CA
L
UP
GR
AD
E\
D
RA
W
IN
GS
\0
2-
D
IS
TR
IB
UT
IO
N
F
LO
O R
PL
AN
S.
dw g, UT
IL
IT
Y
RM
, 2 /4
/2
2:
:0
EXISTING
CABINET
TO REMAIN.
EXT'G
ELEC.
METER
TBR
EXT'G
MAIN
SWITCH
TBR
EXT'G
FUSE
PANEL
TBR
EXISTING
PHASE
CONVERTER
#1
CONTROLS
PNL 1A
CH DISC
SW
PH
CONV
#2
DISC
SW
TO PH CONV #2
CH
PUMP
STRT
PNL 1B
OUT
OF
SVC
ELEVATION PHASE 1: REMOVALS
TO PH CONV #1 AND PH
CONV #2 CONTROLS.
EXT'G
DISC
SW
TBR
PNL 3
EXT'G
COMM
EQUIP
TRU
EXT'G
FUSE
BOX
TBR
T.C.
EXISTING
CABINET
TO REMAIN.
EXT'G
ELEC.
METER
TBR
EXT'G
MAIN
SWITCH
TBR
EXT'G
FUSE
PANEL
TBR
NEW MAIN
PANELBOARD
MDP
NEW
PANEL
B1
ELEVATION PHASE 2: NEW MAIN DISTRIBUTION PANEL & SERVICE
EXT'G
DISC
SW
TBR
PNL 3
EXT'G
COMM
EQUIP
TRU
EXT'G
FUSE
BOX
TBR
9 8 10
T.C.
EXISTING
CABINET
TO REMAIN.
EXT'G
MAIN
SWITCH
TBR
EXT'G
FUSE
PANEL
TBR
21 22
PANEL
PANEL
ABANDONED
NEW MAIN
PANELBOARD
MDP
NEW
PANEL
B1
SVC GRD
ELEVATION PHASE 3: CUT-OVER OF FEEDERS
EXT'G
DISC
SW
TBR
PNL 3
EXT'G
COMM
EQUIP
TRU
EXT'G
FUSE
BOX
TBR
PANEL 1
T.C.T.C.
PHASE 01:
1. REMOVE POWER WIRING TO THE CHILLER FROM THE DISCONNECT SWITCH. SEE
NOTE EN1.
2. REMOVE POWER WIRING TO THE CONDENSING FAN, CIRCULATOR PUMP AND
SHUTOFF SEQUENCE SWITCH, FROM THE LOAD-CENTER. SEE NOTE EN1.
3. REMOVE POWER TO FEEDER PUMP AND THE SUMP PUMP. SEE NOTE EN1.
4. REMOVE EXPOSED, ABANDONED CONDUIT TO 1" BELOW THE FINISHED FLOOR.
PATCH THE CONCRETE FLOOR.
5. REMOVE WIRING TO FLOOR RECEPTACLE AND REMOVE RECEPTACLE. REMOVE
EXPOSED CONDUIT TO 1" BELOW THE FINISHED FLOOR. PATCH THE CONCRETE
FLOOR.
6. REMOVE ALL EQUIPMENT, WIRING AND CONDUIT ASSOCIATED WITH THE CHILLER,
INCLUDING TWO PHASE-CONVERTERS AND ALL ASSOCIATE DEVICES, WIRING AND
CONDUIT.
PHASE 2:
7. BOND MDP SERVICE GROUND TO NEW GROUND BAR.
8. NEW COPPER GROUND BAR.
9. NEW GROUNDING ELECTRODE TO WATER SERVICE ENTRANCE WITH BONDING
JUMPER FROM LOAD-SIDE TO LINE-SIDE OF WATER METER.
10. INSTALL NEW FEEDER BETWEEN EXISTING 400A, 3P MAIN SERVICE CIRCUIT
BREAKER ON EXTERIOR WALL TO NEW MAIN DISTRIBUTION PANEL, MDP.
11. PROVIDE NEW FEEDER TO PANEL B1.
12. PROVIDE NEW FEEDER TO CHILLER.
13. PROVIDE NEW FEEDER TO CONDENSING FAN, CIRCULATOR PUMP AND SHUTOFF
SEQUENCE SWITCH.
14. PROVIDE NEW FEEDERS TO SUMP PUMP AND FEEDER PUMP.
15. REMOVE EXISTING SERVICE WIRING FROM EXISTING ELECTRIC METER TO EXISTING
SINGLE PHASE TRANSFORMER. REMOVE ALL EXPOSED RACEWAY.
16. PROVIDE NEW TEMPORARY FEEDER TO LINE0SIDE OF EXISTING MAIN SERVICE
FUSED SWITCH.
17. REMOVE FEEDER BETWEEN EXISTING METER AND MAIN SERVICE SWITCH AND
REMOVE THE METER AND CABINET.
PHASE 03:
18. REMOVE EXISTING FEEDERS TO EXISTING PANEL B1 AND EXISTING FURNACE
PANEL.
19. PROVIDE NEW FEEDER TO EXISTING FURNACE PANEL.
20. REMOVE EXISTING FEEDER TO PANEL 3, ON THE SECOND FLOOR, AND PROVIDE A
NEW FEEDER TO NEW PANEL 3.
21. REMOVE EXISTING FEEDER TO UNKNOWN EQUIPMENT. INVESTIGATE IN THE FIELD
AND PROVIDE A NEW FEEDER TO THE EQUIPMENT.
22. REMOVE EXISTING FEEDERS (2) TO UNKNOWN EQUIPMENT. INVESTIGATE IN THE
FIELD AND PROVIDE A NEW FEEDERS TO THE EQUIPMENT.
23. REMOVE EXISTING FEEDER TO PANEL 2, ON THE FIRST FLOOR, AND PROVIDE A NEW
FEEDER TO NEW PANEL 2.
24. REMOVE WIRING TO PANEL 1, IN MEN'S ENTRY. REMOVE CONDUIT FROM MAIN
SWITCH TO FIRST FITTING. RETAIN CONCEALED CONDUIT AND EXTEND TO MDP.
PROVIDE NEW WIRING TO PANEL 1.
25. CUT OFF ABANDONED CONDUIT BELOW GRADE AND PATCH FLOOR.
26. REMOVE EXISTING SERVICE GROUNDING ELECTRODE CONDUCTOR.
27. REMOVE MAIN SERVICE SWITCH, DISTRIBUTION EQUIPMENT, RACEWAYS, BOXES,
ACCESSORIES AND APPURTENANCES.
ELEVATIONS NOTES
ELECTRIC ROOM ELEVATIONS
REMOVALS & MODIFICATIONS
E-5
ELECTRICAL DISTRIBUTION UPGRADES AT FVC
FREDERICKSBURG & SPOTSYLVANIA NMP
1013 LAFAYETTE BLVD, FREDERICKSBURG, VA 22401
C:
\U se rs
\r to rp ey
\O ne
D riv e
- D
O I\0
PR
O
JE
CT
S\
FR
SP
\F
RS
P
PM
IS
-2
- F
VC
E
LE
CT
RI
CA
L
UP
GR
AD
E\
D
RA
W
IN
GS
\0
EL
EC
R
M E
LE
VA
TI
O
N S.
dw g, EL
EV
AT
IO
N S, /4
/2
2:
:3
EXISTING
TRANSFORMER
208/120V, 3Ø
SECONDARY
32 3 3
PANEL 2
120/208
1Ø
100 MLO
PANEL 1
120/208
1Ø
100 MLO
PANEL 'B1'
120/208
1Ø
100 MLO
PANEL 'B'
120/208
1Ø
100 MLO
1-LINE RISER DIAGRAM
120/208V, 3Ø
CHILLER
208V, 3PH
79 MCA
PB1 1
EXISTING MAIN SERVICE SWITCH
ON EXTERIOR WALL. PROVIDE
NEW LINE-SIDE FEEDER.
NEW PULL BOX ON WALL IN
CLOSET OFF EXHIBIT EAST B03.
MAIN DISTRIBUTION PANEL (MDP)
PANEL 'FP'
120/208
1Ø
60 MLO
G R
O U
N D
F
LO
O R
FC
U
'S (2
1 TWO 4-3/0 & 1-#3 - 2"C
3-#3 & 1-#8G - 1-1/4"C (100A)
4-#3 & 1-#8G - 1-1/4"C (100A)
4-#4 $ 1-#6G - 1"C
FEEDER SCHEDULE
MAIN DISTRIBUTION PANEL
& 1-LINE RISER DIAGRAM
E-301
ELECTRICAL DISTRIBUTION UPGRADES AT FVC
FREDERICKSBURG & SPOTSYLVANIA NMP
1013 LAFAYETTE BLVD, FREDERICKSBURG, VA 22401
C:
\U se rs
\r to rp ey
\O ne
D riv e
- D
O I\0
PR
O
JE
CT
S\
FR
SP
\F
RS
P
PM
IS
-2
- F
VC
E
LE
CT
RI
CA
L
UP
GR
AD
E\
D
RA
W
IN
GS
\0
2-
D
IS
TR
IB
UT
IO
N
F
LO
O R
PL
AN
S.
dw g, M
D P
R
IS
ER
, 2 /4
/2
2:
:3
120/208 VOLTS, 1 PHASE, 3 WIRE SURFACE MOUNTED NEMA TYPE 1 ENCLOSURE
100 AMPERE MAIN LUGS
SCHEDULE OF EXISTING PANEL 2
LOCATION: SECOND FLOORCOPPER BUSSES & FULL-SIZE GROUND BAR
120/208 VOLTS, 1 PHASE, 3 WIRE SURFACE MOUNTED NEMA TYPE 1 ENCLOSURE
100 AMPERE MAIN LUGS
SCHEDULE OF EXISTING PANEL 1
LOCATION: FIRST FLOORFULL-SIZE GROUND BAR
120/208 VOLTS, 1 PHASE, 3 WIRE SURFACE MOUNTED NEMA TYPE 1 ENCLOSURE
100 AMPERE MAIN LUGS
SCHEDULE OF EXISTING PANEL B
LOCATION: GROUND FLOORCOPPER BUSSES, FULL-SIZE GROUND BAR
120/208 VOLTS, 1 PHASE, 3 WIRE SURFACE MOUNTED NEMA TYPE 1 ENCLOSURE
100 AMPERE MAIN LUGS
SCHEDULE OF EXISTING PANEL B1
LOCATION: GROUND FLOORCOPPER BUSSES, FULL-SIZE GROUND BAR
SCHEDULES OF DISTRIBUTION PANELS
E-302
ELECTRICAL DISTRIBUTION UPGRADES AT FVC
FREDERICKSBURG & SPOTSYLVANIA NMP
1013 LAFAYETTE BLVD, FREDERICKSBURG, VA 22401
C:
\U se rs
\r to rp ey
\O ne
D riv e
- D
O I\0
PR
O
JE
CT
S\
FR
SP
\F
RS
P
PM
IS
-2
- F
VC
E
LE
CT
RI
CA
L
UP
GR
AD
E\
D
RA
W
IN
GS
\0
2-
D
IS
TR
IB
UT
IO
N
F
LO
O R
PL
AN
S.
dw g, LO
AD
C
EN
TE
RS
, 2
/4 /2
2:
:0
File details come from the government source that posted it. Updated .