A06_Drawings_100_CDs_NEPE_V16.pdf
PDF 20 MB Posted
- Attached to
- NEZ PERCE NHP VC RESTROOM REHAB.
- Solicitation number
- 140P8325R0001
About this file
This is a set of architectural construction drawings detailing the renovation of restroom facilities at the Nez Perce National Historical Park Visitor Center. The drawings include demolition plans, new floor plans, interior elevations, wall and ceiling details, and finish schedules for renovating men's, women's, and an accessible unisex restroom.
The drawings specify installation of new ADA-compliant fixtures including wall-mounted sinks, toilets, grab bars, and accessories manufactured by American Standard, Bobrick, and other specified vendors. Key materials include epoxy flooring systems, ceramic tile walls in specified Daltile patterns, and metal stud/gypsum board construction with sound insulation. The drawings provide detailed dimensions and mounting heights for all fixtures to meet accessibility requirements, along with comprehensive mechanical, electrical and plumbing details. Special attention is given to ceiling systems, wall blocking, and other structural elements needed to support the new fixtures and ensure ADA compliance. The project is being managed by the Department of the Interior National Park Service Southeast Region.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 140P8325R0001NEZ_PERCE_NATIONAL_HISTORICAL_PARK_questions_0001.docx | DOCX document | |
| Sol_140P8325R0001_Amd_0001.pdf | ||
| A06_SPECS_100_Project_Manual_NEPE_V16.pdf | ||
| Construction_Contract_Administration.docx | DOCX document | |
| B08_Project_Experience_Questionnaire.docx | DOCX document | |
| B08_Offeror_s_representations_and_certificates_to_be_provided_with_proposal.pdf | ||
| B08_Price_Schedule_Sheet_.xlsx | XLSX spreadsheet | |
| Sol_140P8325R0001.pdf | ||
| B08_Current_TCP110816_Attachment_10.pdf | ||
| B03_Davis_Bacon_Act_WD_ID20250007_SAM_attachmnet__6.pdf | ||
| B08_Sub_contracting_form_12_9_24.xlsx | XLSX spreadsheet | |
| B08_PAST_PERFORMANCE_QUESTIONNAIRE.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:50:24 AM, _AutoCAD PDF (General Documentation).pc3
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:51:09 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text
BASIC DATA:
AutoCAD SHX Text
STATE
AutoCAD SHX Text
NATIONAL PARK SERVICE
AutoCAD SHX Text
PACIFIC WEST REGIONAL OFFICE
AutoCAD SHX Text
REGION
AutoCAD SHX Text
COUNTY
AutoCAD SHX Text
DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text
UNITED STATES
AutoCAD SHX Text
LOCATION WITHIN PARK
AutoCAD SHX Text
NAME OF PARK
AutoCAD SHX Text
TITLE OF PROJECT
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
RESTROOM REMODEL
AutoCAD SHX Text
VISITOR CENTER
AutoCAD SHX Text
NEZ PERCE COUNTY
AutoCAD SHX Text
ID
AutoCAD SHX Text
CONSTRUCTION DRAWINGS
AutoCAD SHX Text
NEZ PERCE N.H.P.
AutoCAD SHX Text
PACIFIC WEST
AutoCAD SHX Text
IDAHO
AutoCAD SHX Text 193561
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 194369
AutoCAD SHX Text
AutoCAD SHX Text & AND AND @ AT AT # NUMBER NUMBER } PLUS OR MINUS ABA ARCHITECTURAL BARRIERS ACT ADDL ADDITIONAL AFF ABOVE FINISH FLOOR AHJ AUTHORITY HAVING JURISDICTION ALUM ALUMINUM BD BOARD BED BEDROOM BLDG BUILDING BLKG BLOCKING B.O. BOTTOM OF BOTTOM OF CENTERLINE CENTERLINE CB CEMENTITIOUS BOARD CJ CONTROL JOINT CLG CEILING CL CLOSET CLR CLEAR(ANCE) CMU CONCRETE MASONRY UNIT(S) C.O. CONTRACTING OFFICER CONTRACTING OFFICER COL(S) COLUMN(S) CONC CONCRETE CONT CONTINUOUS CONSTR CONSTRUCTION CORR CORRIDOR CPT CARPET CT CERAMIC TILE D DRYER DIA DIAMETER DIM DIMENSION DR DOOR DS DOWNSPOUT DW DISHWASHER (E) EXISTING EXISTING EA EACH EL ELEVATION ELEC ELECTRIC(AL) EQ EQUAL EQUIP EQUIPMENT EXT EXTERIOR FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISH FLOOR FG FIBERGLASS DRAIN PAN FIG FIGURE FIN FINISH(ED) FLR FLOOR FN FURNACE F.O. FACE OF FACE OF FOS FACE OF STUD, SLAB FRP FIBER REINFORCED PLASTIC GA GAUGE, GYPSUM ASSOCIATION GALV GALVANIZE(D) GB GRAB BAR GYP GYPSUM GWB GYPSUM WALL BOARD HM HOLLOW METAL HR HOUR HVAC HEATING, VENTILATION, AND AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE ICC INTERNATIONAL CODE COUNCIL INFO INFORMATION INT INTERIOR IRC INTERNATIONAL RESIDENTIAL CODE MANUF MANUFACTURER MAX MAXIMUM MECH MECHANICAL MEP MECHANICAL, ELECTRICAL AND PLUMBING MDF MEDIUM DENSITY FIBERBOARD MIL MILLIMETER MIN MINIMUM MIRR MIRROR(ED) MTD MOUNTED MTL METAL
AutoCAD SHX Text
(N) NEW NEW NA NOT APPLICABLE NFPA NATIONAL FIRE PROTECTION ASSOCIATION NO NUMBER NPS NATIONAL PARK SERVICE NR NON-RATED O.C. ON CENTER ON CENTER OFOI OWNER FURNISH/OWNER INSTALL OH OVERHEAD OPP OPPOSITE OSB ORIENTED STRAND BOARD OTS OPEN TO STRUCTURE PERF PERFORATE(D) PL PLATE, PROPERTY LINE PLAM PLASTIC LAMINATE PT PRESSURE TREATED, PAINT PTD PAINTED PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE RCP REFLECTED CEILING PLAN REF REFRIGERATOR, REFERENCE REQD REQUIRED REV REVERSE(D) RO ROUGH OPENING RS RESILIENT SHEET GOODS RWB RESILIENT WALL BASE
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text 46°26'50.51"N 116°49'23.78"W
AutoCAD SHX Text ADOPTED CODES: 2024 INTERNATIONAL BUILDING CODE (IBC) 2021 INTERNATIONAL FIRE CODE (IFC) 2017 INTERNATIONAL ELECTRICAL CODE (NEC) 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC): (INCLUDING LOCAL CODES AND AMENDMENTS) SINGLE USE OCCUPANCY CLASSIFICATION: A-3 ASSEMBLY MIXED USE OCCUPANCY CLASSIFICATIONS: NONE NON-SEPARATED USE: NO SEPARATED (FIRE BARRIER): NO FIRE SEPARATED: NO AREA OF INTERIOR REMODEL 480 SF TYPE OF CONSTRUCTION PER IBC 2015: IIIB FIRE ALARM SYSTEM: YES AUTOMATIC FIRE SPRINKLERS: YES NUMBER OF STORIES: 1
AutoCAD SHX Text
CODE SUMMARY
AutoCAD SHX Text SAMF SELF-ADHERED MEMBRANE FLASHING SC SOLID CORE SF SQUARE FEET SIM SIMILAR SPEC SPECIFICATION(S) STC SOUND TRANSMISSION CLASS STD STANDARD STOR STORAGE STRUCT STRUCTURAL T TEMPERED, TREAD TBD TO BE DETERMINED TEL TELEPHONE THK THICK TJI TRUSS JOIST I-JOIST T.O. TOP OF TOP OF TYP TYPICAL UL UNDERWRITER'S LABORATORY UNO UNLESS NOTED OTHERWISE UTIL UTILITY VRFY VERIFY W WASHER W/ WITH WASO WASHINGTON, D.C. AREA SERVICE OFFICE WD WOOD WH WATER HEATER WIN WINDOW WR WATER RESISTANT WRB WEATHER RESISTANT BARRIER W/D WASHER AND DRYER
AutoCAD SHX Text
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, EXISTING UTILITIES, FIXTURES AND CONDITIONS THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, EXISTING UTILITIES, FIXTURES AND CONDITIONS AT THE SITE. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF AND RESOLVED WITH THE CONTRACTING OFFICER 2. DO NOT SCALE DRAWINGS: USE DIMENSIONS SHOWN. ALL DIMENSIONS SHALL BE VERIFIED IN THE DO NOT SCALE DRAWINGS: USE DIMENSIONS SHOWN. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD. DIMENSIONS SHOWN AT (E) CONDITIONS ARE TO FACE OF (E) FINISH. DIMENSIONS OF (E) CONDITIONS ARE FOR REFERENCE ONLY AND SHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD. WHERE NO DIMENSION IS PROVIDED CONSULT WITH THE CONTRACTING OFFICER FOR CLARIFICATION BEFORE PROCEEDING WITH AFFECTED WORK. ALL DIMENSIONS ARE TO THE FACE OF GYP WALL, CENTERLINE OF COLUMNS, FACE OF CONCRETE WALLS, FACE OF CMU WALLS, CENTERLINE OF FIXTURES, AND CENTERLINE OF OPENINGS, UNLESS OTHERWISE NOTED. 3. CONTRACTOR SHALL PROVIDE BACKING/BLOCKING AS REQUIRED FOR THE PROPER ANCHORAGE CONTRACTOR SHALL PROVIDE BACKING/BLOCKING AS REQUIRED FOR THE PROPER ANCHORAGE OF ALL WALL ATTACHED ITEMS SUCH AS TOILET ACCESSORIES, WALL-MOUNTED FIXTURES, DOOR STOPS, ETC. 4. THE CONTRACTOR IS RESPONSIBLE FOR ADVANCED REVIEW OF THE WORK REQUIRED IN THE THE CONTRACTOR IS RESPONSIBLE FOR ADVANCED REVIEW OF THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY. IF THE CONTRACTOR FINDS DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS OR SPECIFICATIONS, THEN THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IMMEDIATELY. THE CONTRACTOR SHALL WORK TO HAVE ALL DISCREPANCIES RESOLVED WELL IN ADVANCE OF ACTUAL CONSTRUCTION OCCURRING. NO CLAIMS FOR NO CLAIMS FOR EXTRA COMPENSATION FOR WORK THAT COULD HAVE BEEN FORESEEN BY SUCH INSPECTION, WHETHER SHOWN ON CONTRACT DOCUMENTS OR NOT, SHALL BE ACCEPTED OR PAID. 5. ALL CONSTRUCTION AND INSTALLATION WORK SHOWN ON DRAWINGS SHALL BE DONE IN ALL CONSTRUCTION AND INSTALLATION WORK SHOWN ON DRAWINGS SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. USE METHODS AS REQUIRED TO COMPLETE WORK WITHIN LIMITATIONS OF ALL PREVAILING LAWS AND CODES. IN CASE OF DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS, REFERENCED STANDARDS AND THE GOVERNING CODES, THE CONTRACTING OFFICER WILL DETERMINE WHICH SHALL GOVERN. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF AND RESOLVED WITH THE CONTRACTING OFFICER BEFORE PROCEEDING WITH THE WORK. 6. REPETITIVE FEATURES NOTED TYPICAL ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF REPETITIVE FEATURES NOTED TYPICAL ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. REPETITIVE FEATURES NOT NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF NOTED IN FULL. 7. CONTRACTOR SHALL VERIFY AND COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS FOR CONTRACTOR SHALL VERIFY AND COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK AND EQUIPMENT WITH EACH TRADE. 8. INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS AND WHERE INSTALL METAL TRIM ON ALL GYPSUM BOARD EDGES ABUTTING OTHER MATERIALS AND WHERE GYPSUM BOARD IS STOPPED SHORT OF OTHER MATERIALS TO FORM A RECESS OR REVEAL. 9. VERIFY THAT REQUIRED OPERATION AND MAINTENANCE CLEARANCES ARE PROVIDED FOR ALL VERIFY THAT REQUIRED OPERATION AND MAINTENANCE CLEARANCES ARE PROVIDED FOR ALL EQUIPMENT ITEMS. INSTALL ALL ITEMS IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS EXCEPT WHEN IN CONFLICT WITH THE SPECIFICATIONS HEREIN, IN WHICH CASE THE MORE STRINGENT REQUIREMENTS SHALL BE COMPLIED WITH. NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY CONFLICTS. 10. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL REQUIRED UTILITY SHUT-DOWNS WITH CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL REQUIRED UTILITY SHUT-DOWNS WITH CONTRACTING OFFICER AND PARK POINT OF CONTACT, NOTIFY CONTRACTING OFFICER OF INTENDED SHUTDOWN AT LEAST 48 HOURS PRIOR TO SCHEDULED SHUTDOWN. 11. CONTRACTOR SHALL IMMEDIATELY NOTIFY CONTRACTING OFFICER IF HAZARDOUS MATERIAL IS CONTRACTOR SHALL IMMEDIATELY NOTIFY CONTRACTING OFFICER IF HAZARDOUS MATERIAL IS ENCOUNTERED DURING DEMOLITION OR CONSTRUCTION. REMOVAL AND DISPOSAL OF HAZARDOUS MATERIALS SHALL BE ACCOMPLISHED IN COMPLIANCE WITH STATE REGULATIONS. IT IS NOT ANTICIPATED THAT ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE PRESENT IN THE AREA OF WORK. 12. ALL WASTE AND REFUSE CAUSED IN CONNECTION WITH THE WORK SHALL BE REMOVED FROM ALL WASTE AND REFUSE CAUSED IN CONNECTION WITH THE WORK SHALL BE REMOVED FROM THE PREMISES AND DISPOSED OF BY THE CONTRACTOR. THE PREMISES SHALL BE LEFT CLEAR AND CLEAN TO THE SATISFACTION OF THE CONTRACTING OFFICER. COORDINATE THE AVAILABILITY AND LOCATION OF RECYCLING DUMPSTER AND TRASH DUMPSTER WITH CONTRACTING OFFICER. TRASH SHALL BE DISPOSED OF AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION (AHJ). 13. IT IS CONTRACTORS RESPONSIBILITY TO REMOVE, PROTECT AND SAFELY STORE FIXTURES AND/OR IT IS CONTRACTORS RESPONSIBILITY TO REMOVE, PROTECT AND SAFELY STORE FIXTURES AND/OR EQUIPMENT AS NOTED IN PLANS AND SPECIFICATIONS. 14. SAFETY MEASURES: AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE SAFETY MEASURES: AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONDITIONS AT THE JOB SITE, INCLUDING SAFETY OF PEOPLE AND PROPERTY. CONTRACTING OFFICER SITE VISITS ARE NOT INTENDED TO REVIEW THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 15. INSTALL MANUFACTURED MATERIALS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS INSTALL MANUFACTURED MATERIALS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS, UNLESS OTHERWISE INSTRUCTED. 16. APPLICATION OF FINISH: SURFACES PREVIOUSLY PREPARED OR INSTALLED BY ANOTHER TRADE APPLICATION OF FINISH: SURFACES PREVIOUSLY PREPARED OR INSTALLED BY ANOTHER TRADE SHALL BE INSPECTED CAREFULLY BY THE CONTRACTOR BEFORE APPLYING SUBSEQUENT MATERIALS OR FINISHES. IF SURFACES ARE NOT ACCEPTABLE, THE CONTRACTING OFFICER SHALL BE NOTIFIED IMMEDIATELY IN ORDER THAT CORRECTIONS MAY BE MADE. APPLICATIONS OF FINISHES WILL BE CONSTRUED AS ACCEPTANCE OF RESPONSIBILITY BY THE SUBCONTRACTOR FOR THE BASE UPON WHICH IT IS APPLIED. 17. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. THE DRAWINGS AND SPECIFICATIONS REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE COMPLEMENTARY. CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE DRAWINGS, SPECIFICATIONS, NOTES AND DETAILS SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER AND RESOLVED BEFORE PROCEEDING WITH WORK. 18. CONTRACTOR TO PERFORM DEMOLITION AS REQUIRED FOR INSTALLATION OF NEW WORK. CONTRACTOR TO PERFORM DEMOLITION AS REQUIRED FOR INSTALLATION OF NEW WORK. DEMOLITION DRAWINGS ARE NOT INCLUSIVE OF EVERY CONDITION THAT MAY BE ENCOUNTERED 19. PROTECT AREAS OUTSIDE AREA OF WORK FROM DAMAGE DURING CONSTRUCTION. PROTECTION PROTECT AREAS OUTSIDE AREA OF WORK FROM DAMAGE DURING CONSTRUCTION. PROTECTION REQUIREMENTS INCLUDE THE INSTALLATION OF PHYSICAL BARRIERS TO RESTRICT ACCESS TO, AND PREVENT DAMAGE FROM, CONSTRUCTION ACTIVITIES RELATED TO THIS WORK. PROTECTION SHALL BE OF REQUIRED SIZE AND THICKNESS TO WITHSTAND IMPACT FROM FALLING DEBRIS, ROLLING EQUIPMENT, AND DELIVERY OF MATERIALS. BARRIER MATERIALS ARE TO BE INSTALLED WITHOUT ATTACHMENT DIRECTLY TO ADJACENT HISTORIC BUILDINGS, SURFACE, OR SITE WORK. PROTECT EXISTING SITE IMPROVEMENTS, APPURTENANCES, AND LANDSCAPING. COVER AND PROTECT FURNITURE, FURNISHINGS, SUPPLIES, AND EQUIPMENT THAT HAVE NOT BEEN REMOVED. PROVIDE TEMPORARY WEATHER PROTECTION TO ENSURE THAT NO WATER LEAKAGE OR DAMAGE OCCURS TO STRUCTURE OR INTERIOR AREAS OF EXISTING BUILDING. 20. PATCH AND REFINISH ALL (E) SURFACES AFFECTED BY DEMO AND NEW WORK.PATCH AND REFINISH ALL (E) SURFACES AFFECTED BY DEMO AND NEW WORK.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
DOOR SYMBOL
AutoCAD SHX Text
DETAIL: DETAIL NUMBER SHEETS SYMBOL OCCURS ON SHEET SYMBOL REFERENCES
AutoCAD SHX Text
NORTH ARROW
AutoCAD SHX Text
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
ELEVATION: ELEVATION NUMBER SHEETS SYMBOL OCCURS ON SHEET SYMBOL REFERENCES
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
XX
AutoCAD SHX Text X
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text COVER SHEET A1 TYP ACCESSIBLE DETAILS TYP ACCESSIBLE DETAILS A2 DEMOLITION PLANS DEMOLITION PLANS A3 DEMOLITION REFLECTED CEILING PLAN DEMOLITION REFLECTED CEILING PLAN A4 NEW FLOOR PLAN NEW FLOOR PLAN A5 NEW REFLECTED CEILING NEW REFLECTED CEILING A6 INTERIOR DETAILS (1 OF 2) INTERIOR DETAILS (1 OF 2) A7 INTERIOR DETAILS (2 OF 2) INTERIOR DETAILS (2 OF 2) A8 WALL AND CEILING DETAILS WALL AND CEILING DETAILS A9 SCHEDULES SCHEDULES
AutoCAD SHX Text
SHEET INDEX
SHEET INDEX
VERTICAL CHANGES IN LEVEL
BEVELED CHANGES IN LEVEL
1/4
MA
X 1/2
" M
AX
NAPKIN /
TAMPON
DISPOSAL
54" MIN.
36" GRAB BAR
12" MAX.
39" - 41" MIN.
9"
" T
O B
O
TT
O M
7" - 9"
42" GRAB BAR
TOILET PAPER
DISPENSER
WALL HUNG
TOILET (W.C.)
" M
IN
. T
O B
O T.
" M
AX
. T
O T
O P
6"
TO
P
O F
G R
AB
B
AR
(I
.C .C
. 6
.4
1"
BO
T.
O F
G R
AB
B
AR
(I
.C .C
. 6
.5 .1
" M
IN
" M
AX
SEAT COVER
DISPENSER
" M
AX
9"
16" - 18" 17" - 19"
6" 36" MIN.
MIRROR
" M
IN
" M
AX
" M
AX
3' -3
" M
AX
SOAP
DISPENSER
LAVATORY
INSULATE SINK PIPES
" M
IN
" M
AX
15" MIN.
SO
AP
A N
D P
AP
ER
TO
W
EL
D
IS
PE
N
SE
R S
CENTERLINE
OF
EDGE OF
DISPENSER
SINK TO
/2
DISPENSER/
WASTE
RECEPTACLE 40
NAPKIN/
TAMPON
DISPENSER
NAPKIN/
TAMPON
DISPOSAL
1 3/4" = 1'-0"
MOUNTING HEIGHTS
603 TOILET AND BATHING ROOMS:
1.) 603.2.1 TURNING SPACE:
A TURNING SPACE COMPLYING WITH 304 SHALL BE PROVIDED WITHIN THE ROOM.
2.) 603.2.2 OVERLAP:
CLEAR FLOOR SPACES, CLEARANCES AT FIXTURES, AND TURNING SPACES SHALL
BE PERMITTED TO OVERLAP.
3.) 603.2.3 DOOR SWING:
DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE FOR
ANY FIXTURE.
EXCEPTIONS:
1.) DOORS TO A TOILET AND BATHING ROOM FOR A SINGLE OCCUPANT.
ACCESSED ONLY THROUGH A PRIVATE OFFICE AND NOT FOR COMMON USE
OR PUBLIC USE HALL BE PERMITTED TO SWING INTO THE CLEAR FLOOR
SPACE. PROVIDED THE SWING OF THE DOOR CAN BE REVERSED TO MEET
SECTION 603.2.3
2 3/4" = 1'-0"
RESTROOM SIGNAGE
6' -8
" M
IN
. H
EI
G H
T
32" MIN. CLEAR
FLOORFLOOR
FLOOR
PROVIDE LEVER TYPE HANDLE
DOOR LATCH WITH OPENING
FORCE OF 5 LBS. MAX.
(INTERIOR DOOR), DOOR
HANDLES SHALL NOT REQUIRE
TIGHT GRASP, PINCHING OR
TWISTING OF WRIST TO OPERATE
NOTES:
PROVIDE AT H.C. TOILET ROOM
(MOUNT CENTERED ON DOOR)
MEN
6"
8"
1" 4" 3 1/
2"
MOUNT WITH
DOUBLE
BACK TAPE
3/4" HIGH WHITE
TACTILE LETTERS w/
BRAILLE CHARACTERS
1/2" RADIUS
CORNERS,
TYPICAL
WHITE GRAPHIC
SYMBOLS AT
RESTROOMS WITH
1/4" GRAY PLASTIC
LAMINATE WITH
POLISHED EDGES
MEN
5' -4
" M
AX
5 1 1/2" = 1'-0"
ABAAS GRABBAR ATTACHMENT 6 N.T.S.
SIGNAGE
CENTERLINE OF DOOR AND SIGN
5'-0"
A.F.F.
MEN / WOMEN OR UNISEX AS REQUIRED PER PLAN
SEE PLAN FOR SIGNAGE LOCATIONS
C
EN
TE
R
LI
N
E O
F
SI
G N
RESTROOM SIGNAGE
NOTE: IDENTIFICATION SYMBOLS
PER ADA SECTION 4.30 SIGNAGE
INTERNATIONAL SYMBOL OF ACCESSIBILITY
IBC SECTION 1110 - SIGNAGE
1110.1 SIGNS
7.) UNISEX TOILETS AND BATHING ROOMS
ICC ANSI 117.1
703.5 PICTOGRAMS
703.5.2 PICTOGRAM FIELD. PICTOGRAMS SHALL HAVE A
6 INCH FIELD MIN. IN HEIGHT.
703.6 SYMBOLS OF ACCESSIBILITY
" M
IN
" M
AX
IC
C
.5
" M
AX
IC
C
.3
" M
IN
IC
C
.3 .3
6 MAX.
PER ICC 306.2.4
LEVER
VALVE
M
IR
R O
R (S
AF
ET
Y G
LA
ZI
N G
8" MIN.
11" MIN.
KNEE
CLEARANCE
9" M
IN
PIPING
17" MAX.
17" MIN. - 25" MAX.
KNEE/TOE
CLEARANCE
3 3/4" = 1'-0"
ABAAS CLEARANCE
NOTES:
1.) TOE CLEARANCE 30" MINIMUM IN WIDTH
2.) KNEE CLEARANCE 30" MINIMUM IN WIDTH
3.) CONTRASTING COLOR BETWEEN COUNTER TOP AND FLOORING.
4.) CLEAR KNEE SPACE TO BE 29" A.F.F. MIN.
SEE DETAIL
DETAIL
ELEVATION
IC
C
6.
2.
PROTECTED
ICC 606.6
32" MIN.
4 3/8" = 1'-0"
DOOR CLEARANCE
" M
AX
32" MIN.
36" MIN.
32" MIN.
ACCESSIBLE PER ICC 604.2
AMBULATORY PER ICC 604.2
12" MIN. 24" MIN.
FLUSH HANDLE
ON WIDE SIDE
OF STALL OR
ROOM
6"
I.C .C
. 6
.4
I.C .C
. 6
.4
42" MIN.
18" VERT.
GRAB BAR
24" MIN.
GRAB BARS PER I.B.C. 1110.2.2.4GRAB BAR SECTION
1 1/2" MAX. 1 1/4" - 2" MAX.
PER I.C.C. 609.2.1
METAL STUDS PER PLAN
16GA. METAL STUD
BLKG. w/ 1- A35
CLIP TOP AND BOTTOM
1/4"Ø SHEET METAL
SCREWS TO METAL
BLOCKING
1 1/4"Ø GRAB BAR
SEE 5/A4.01
BACKING
DETAIL
1.) 604.5.1 FIXED WALL GRAB BARS:
FIXED SIDEWALL GRAB BARS SHALL BE 42 INCHES MIN. IN LENGTH, LOCATED 12 INCHES
MAX. FROM THE REAR WALL AND EXTENDING 54 INCHES MIN. FROM THE REAR WALL IN
ADDITION, A VERTICAL GRAB BAR 18 INCHES MIN. IN LENGTH SHALL BE MOUNTED WITH
THE BOTTOM OF THE BAR LOCATED BETWEEN 39 INCHES ABD 41 INCHES ABOVE THE FLOOR,
AND 41 INCHES FROM THE REAR WALL.
2.) 604.5.2 REAR WALL GRAB BARS:
3.) 609.1 GENERAL:
GRAB BARS IN ACCESSIBLE TOILET OR BATHING FACILITIES SHALL COMPLY WITH SECTION 1110
4.) 609.2.1 CIRCULAR CROSS SECTION:
GRAB BARS WITH A CIRCULAR CROSS SECTION SHALL HAVE A OUTSIDE DIAMETER OF
1 1/4" MIN. AND 2 INCHES MAX.
5.) 609.2.2 NON-CIRCULAR CROSS SECTION:
GRAB BARS WITH A NON-CIRCULAR CROSS SECTION SHALL HAVE A CROSS SECTION DIMENSION
OF 2 INCHES MAX. AND PERIMETER DIMENSION OF 4 INCHES MIN. AND 4.8 INCHES MAX.
6.) 609.2.3 SPACING:
WALL AND THE GRAB BARS AND PROJECTING OBJECTS BELOW AND AT THE ENDS OF GRAB BARS
SHALL BE 1 1/2" MIN. THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS ABOVE
THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1 1/2". THE SPACE BETWEEN THE
THE GRAB BAR SHALL BE 12" MIN.
7.) 609.4 POSITION OF GRAB BARS:
GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MIN. AND 36 INCHES MAX. ABOVE THE FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. AT WATER CLOSETS
PRIMARILY FOR CHILDREN USE COMPLYING WITH SECTION 604.10, GRAB BARS SHALL BE
INSTALLED IN A HORIZONTAL POSITION 18" MIN. AND 27" MAX. ABOVE THE FLOOR MEASURED
TO THE TOP OF GRIPPING SURFACE.
8.) 609.5 SURFACE HAZARDS:
GRAB BARS, AND ANY WALL OR OTHER SURFACES ADJACENT TO GRAB BARS, SHALL BE FREE
OF SHARP OR ABRASIVE ELEMENTS. EDGES SHALL BE ROUNDED.
THE REAR WALL GRAB BAR SHALL BE 36" MIN. IN LENGTH AND EXTEND FROM THE
CENTERLINE OF THE WATER CLOSET 12" MIN. ON THE SIDE OF CLOSET TO WALL AND
24 INCHES MIN. ON THE TRANSFER SIDE.
9.) 609.6 FITTINGS:
GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
2.) WHERE THE ROOM IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE
COMPLYING WITH SECTION 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE
ARC OF THE DOOR SWING.
4.) 603.3 MIRRORS:
WITH THE BOTTOM EDGE 40 INCHES MAX. ABOVE THE FLOOR. MIRRORS NOT
5.) 603.4 COAT HOOKS AND SHELVES:
6.) 604.1 GENERAL:
MIRRORS LOCATED ABOVE LAVATORIES, SINKS OR COUNTERS SHALL BE MOUNTED
LOCATED ABOVE LAVATORIES, SINKS OR COUNTERS HALL BE MOUNTED WITH THE
BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES MAX. ABOVE THE FLOOR.
COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH SPECIFIED
IN SECTION 308. SHELVES SHALL BE 40 INCHES MIN. AND 48 INCHES MAX.
ABOVE THE FLOOR.
SECTION 604. COMPARTMENTS CONTAINING MORE THAN ONE PLUMBING FIXTURE
SHALL COMPLY WITH SECTION 603. WHEELCHAIR ACCESSIBLE COMPARTMENTS
ACCESSIBLE WATER CLOSETS AND TOILET COMPARTMENTS SHALL COMPLY WITH
SHALL COMPLY WITH SECTION 604.8 AMBULATORY ACCESSIBLE COMPARTMENTS
SHALL COMPLY WITH SECTION 604.9
7.) 604.2 LOCATION:
THE WATER CLOSET SHALL BE LOCATED WITH A WALL OR PARTITION TO THE REAR AND
TO ONE SIDE. THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM
TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION. WATER CLOSET LOCATED
IN AMBULATORY ACCESSIBLE COMPARTMENTS SPECIFIED IN SECTION 604.9 SHALL HAVE
THE CENTERLINE OF THE WATER CLOSET 17 INCHES MAX. FOR THE SIDE OF WALL OR
PARTITION.
8.) 604.3 CLEARANCE:
9.) 604.3.1 SIZE:
A CLEARANCE AROUND A WATER CLOSET 60 INCHES MINIMUM, MEASURED PERPENDICULAR
FROM THE SIDE WALL, AND 56 INCHES MIN. MEASURED PERPENDICULAR FROM THE REAR
WALL, SHALL BE PROVIDED.
10.) 604.3.2 OVERLAP:
THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO
OVERLAP THE WATER CLOSET. ASSOCIATED GRAB BARS, PAPER DISPENSERS, SANITARY
NAPKIN RECEPTACLES, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES. CLEAR FLOOR
SPACE AT OTHER FIXTURES AND THE TURNING SPACE. NO OTHER FIXTURES OR
OBSTRUCTIONS SHALL BE WITHIN THE REQUIRED WATER CLOSET CLEARANCES.
11.) 604.4 HEIGHT:
ABOVE THE FLOOR, MEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG
THE HEIGHT OF WATER CLOSET SEATS SHALL BE 17 INCHES MIN. AND 19 INCHES MAX.
TO RETURN TO A LIFTED POSITION.
FLOOR
L.L.C. 404 DOORS AND DOORWAYS:
1.) 404.1 GENERAL:
DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY
WITH SECTION 404.
2.) 404.2 MANUAL DOORS:
MANUAL DOORS AND DOORWAYS AND MANUAL GATES, INCLUDING TICKET GATES,
SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 404.2
3.) 404.2.1 DOUBLE-LEAF DOORS AND GATES:
AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL
COMPLY WITH SECTIONS 404.2.2 AND 404.2.3
4.) 404.2.2 CLEAR WIDTH:
WIDTH OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF
THE DOOR AND STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS DOOR AND DOORWAYS
WITHOUT DOORS MORE THAN 24 INCHES IN DEPTH SHALL PROVIDE A CLEAR OPENINGS
WIDTH OF 36 INCHES MIN. THERE SHALL BE NO PROJECTIONS INTO THE CLEAR
CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FLOOR SHALL
NOT EXCEED 4 INCHES.
DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32 INCHES MIN. CLEAR OPENING
OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FLOOR. PROJECTIONS INTO THE
EXCEPTIONS:
1.) DOOR CLOSER AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MIN.
ABOVE THE FLOOR
2.) IN ALTERATIONS, PROJECTION OF 5/8 INCH MAX. INTO THE REQUIRED CLEAR
OPENING WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP.
5.) 404.2.3.5 FLOOR SURFACE:
FLOOR SURFACE WITHIN THE MANEUVERING CLEARANCES SHALL HAVE A SLOPE NOT
STEEPER THAN 1:48 AND SHALL COMPLY WITH SECTION 302
6.) 404.2.4 THRESHOLDS AT DOORWAYS:
IF PROVIDED THRESHOLD OR DOORWAYS SHALL BE 1/2 INCH MA.X IN HEIGHT.
RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH
SECTIONS 302 AND 303.
5.) CLEARANCE REDUCTION. BETWEEN 9" AND 27" ABOVE THE FLOOR, THE KNEE
CLEARANCE SHALL BE PERMITTED TO BE REDUCED AT A RATE OF 1" FOR EACH 6" IN HEIGHT.
REQUIRED ACCESSIBLE ELEMENTS HALL BE IDENTIFIED BY
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT THE
FOLLOWING LOCATIONS.
703.5.1 GENERAL PICTOGRAMS SHALL COMPLY WITH
SECTION 703.5
CHARACTERS OR BRAILLE SHALL NOT BE LOCATED IN THE
PICTOGRAMS FIELD.
TABLE 404.2.3.1 MANEUVERING AT MANUAL SWINGING DOORS
TYPE OF USE MINIMUM MANEUVERING CLEARANCES
APPROACH DIRECTION
DOOR SIDE
PERPENDICULAR TO DOORWAY
PARALLEL TO DOORWAY
(BEYOND LATCH UNLESS NOTED)
FROM START
FROM START
FROM HINGE SIDE
FROM HINGE SIDE
FROM HINGE SIDE
FROM LATCH SIDE
FROM LATCH SIDE
PULL
PUSH
PULL
PULL
PUSH
PULL
PUSH
60 INCHES
48 INCHES
60 INCHES
54 INCHES
42 INCHES (1)
48 INCHES (2)
42 INCHES (3)
18 INCHES
0 INCHES (3)
36 INCHES
42 INCHES
22 INCHES (3 & 4)
24 INCHES
24 INCHES
(A)
HINGED
DOOR
(B) SLIDING DOOR
(C) FOLDING DOOR
(D) DOORWAYS WITHOUT DOORS
703.5.3 FINISH AND CONTRAST. PICTOGRAMS AND THEIR
FIELDS SHALL HAVE A NON GLARE FINISH. PICTOGRAMS
SHALL CONTRAST WITH THEIR FIELDS, WITH EITHER A LIGHT
PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A
LIGHT FIELD.
703.6.2 FINISH AND CONTRAST.
SYMBOLS OF ACCESSIBILITY AND
THEIR FIELDS SHALL HAVE A NON
GLARE FINISH. SYMBOLS OF
ACCESSIBILITY SHALL CONTRAST
WITH THEIR FIELDS, WITH EITHER A
LIGHT SYMBOL ON A DARK FIELD OR
DARK SYMBOL ON A LIGHT FIELD.
703.6.1 GENERAL SYMBOLS OF ACCESSIBILITY
SHALL COMPLY WITH SECTION 703.6
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF
A1 TYP ACCESSIBLE DETAILS
194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
A1
2 ACCESSIBLE THRESHOLD
09/01/24
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:50:41 AM, _AutoCAD PDF (General Documentation).pc3
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF
A2 DEMOLITION PLANS
194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
A2
1 EXISTING DEMOLITION FLOOR PLAN
09/01/24
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:50:28 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text
(E) WOMEN'S RESTROOMWOMEN'S RESTROOM
AutoCAD SHX Text
REMOVE (E) SINKS, COUNTERTOPS, MIRRORS & ALL TOILET ROOM ACCESSORIES, TYP.
AutoCAD SHX Text
REMOVE (E) TOILET PARTITIONS AND DOORS TYP. THROUGHOUT
AutoCAD SHX Text
REMOVE WALL FINISH/FRAMING AS NEEDED TO DEMO (E) PIPING, TYP. THROUGHOUT
AutoCAD SHX Text
REMOVE (E) HAND DRYERS AND SAVE FOR RE-INSTALLATION
AutoCAD SHX Text
REMOVE HAND DRYER AND SAVE FOR RE-INSTALLATION
AutoCAD SHX Text
REMOVE ALL (E) FLOOR AND WALL TILE THROUGHOUT
AutoCAD SHX Text
REMOVE (E) TOILETS & FLUSH VALVES TYP THROUGHOUT.
AutoCAD SHX Text
REMOVE WALL FINISH/FRAMING AS NEEDED TO DEMO (E) PIPING, TYP. THROUGHOUT
AutoCAD SHX Text
HATCHED AREA NIC
AutoCAD SHX Text
REMOVE (E) TOILETS, & FLUSH VALVES TYP.
AutoCAD SHX Text DEMOLITION NOTES 1) THE CONTRACTOR SHALL VERIFY IN THE FIELD ALL THE CONTRACTOR SHALL VERIFY IN THE FIELD ALL LINES, LEVELS, DIMENSIONS, AND EXISTING CONDITIONS. THE INFORMATION ON THE DRAWINGS IS THE RESULT OF FIELD SURVEY AND IS ACCURATE TO THE BEST OF OUR KNOWLEDGE IT IS INTENDED, HOWEVER, AS A GUIDE FOR USE IN VERIFICATION ONLY. 2) ANY EXISTING EQUIPMENT IN THE AREA OF NEW ANY EXISTING EQUIPMENT IN THE AREA OF NEW CONSTRUCTION NOT SHOWN ON THE EXISTING PLANS SHALL BE DOCUMENTED AND SUBMITTED TO THE CO/COR FOR DETERMINATION OF ACTION REQUIRED. 3) WHENEVER THE REMOVAL OF EXISTING CONSTRUCTION WHENEVER THE REMOVAL OF EXISTING CONSTRUCTION REVEALS WORK THAT IS TO REMAIN, BUT CONFLICTS WITH NEW CONSTRUCTION, CONTRACTOR SHALL NOTIFY THE CO/COR FOR DIRECTION. 4) THE CONTRACTOR SHALL COORDINATE WITH THE CO/COR THE CONTRACTOR SHALL COORDINATE WITH THE CO/COR PRIOR TO REMOVAL OF ITEM/MATERIAL THAT IS TO BE PROTECTED AND MAINTAINED. 5) IF ANY ITEM/MATERIAL THAT IS SCHEDULED TO REMAIN IF ANY ITEM/MATERIAL THAT IS SCHEDULED TO REMAIN IN OPERATION IS DAMAGED BY THE CONTRACTOR, IT SHALL BE REPLACED TO ITS ORIGINAL CONDITION, SATISFACTORY TO THE CO/COR AT THE CONTRACTORS EXPENSE. 6) IF HAZARDOUS MATERIALS ARE PRESENT ON SITE THE IF HAZARDOUS MATERIALS ARE PRESENT ON SITE THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CO/COR. ALL ABATEMENT SHALL MEET ALL APPLICABLE CODES & REGULATIONS. 7) REMOVE ALL (E) WALL BOARD AS NEEDED TO INSTALL REMOVE ALL (E) WALL BOARD AS NEEDED TO INSTALL BLOCKING, POWER OR PIPING AS REQD. 8) PATCH AND REFINISH ALL (E) SURFACES AFFECTED BY PATCH AND REFINISH ALL (E) SURFACES AFFECTED BY DEMO NEW WORK TYP. 9) PROTECT ALL ADJACENT SYSTEMS AND STRUCTURES PROTECT ALL ADJACENT SYSTEMS AND STRUCTURES WITH APPROPRIATE SHORING, AND PROTECTION.
AutoCAD SHX Text
PROTECT OR RETAIN EMERGENCY LIGHTS MAINTAIN LOCATION
AutoCAD SHX Text
PROTECT OR MAINTAIN ACC. DOOR OPENER
AutoCAD SHX Text
REMOVE (E) UTILITY SINK TO BE REPLACED WITH (N)
AutoCAD SHX Text
REMOVE (E) DOOR, FRAME HARDWARE & THRESHOLD
AutoCAD SHX Text
REMOVE (E) DOOR, FRAME HARDWARE & THRESHOLD
AutoCAD SHX Text
REMOVE (E) DOOR, FRAME HARDWARE & THRESHOLD
AutoCAD SHX Text
REMOVE ALL (E) FLOOR AND WALL TILE THROUGHOUT
AutoCAD SHX Text
(E) UTILITY CLOSETUTILITY CLOSET
AutoCAD SHX Text
HATCHED AREA NIC
AutoCAD SHX Text
PROTECT OR RETAIN EMERGENCY LIGHTS MAINTAIN LOCATION
AutoCAD SHX Text
REMOVE ALL (E) URINALS & URINAL SCREENS TYP.
AutoCAD SHX Text
REMOVE (E) HAND DRYERS AND SAVE FOR RE-INSTALLATION
AutoCAD SHX Text
REMOVE (E) SINKS, COUNTERTOPS, MIRRORS & ALL TOILET ROOM ACCESSORIES, TYP.
AutoCAD SHX Text
DOOR (E) NIC
AutoCAD SHX Text
PROTECT OR RETAIN
AutoCAD SHX Text
PROTECT OR RETAIN
AutoCAD SHX Text
PROTECT OR RETAIN
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
REMOVE (E) NAPKIN/TAMPON DISPENSER
AutoCAD SHX Text
REMOVE ALL (E) FLOOR AND WALL TILE THROUGHOUT
AutoCAD SHX Text
(E) MEN'S RESTROOMMEN'S RESTROOM
REMOVE ALL (E) FLOOR AND WALL TILE THROUGHOUT
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF
A3 DEMOLITION REFLECTED
CEILING PLAN 194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
A3
1 EXISTING DEMOLITION REFLECTED CEILING PLAN
09/01/24
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:50:52 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text
REMOVE ALL (E) FLUORESCENT LIGHT FIXTURES AND RETURN TO PARK.
AutoCAD SHX Text
(E) WOMEN'S RESTROOMWOMEN'S RESTROOM
AutoCAD SHX Text
(E) MEN'S RESTROOMMEN'S RESTROOM
AutoCAD SHX Text
REMOVE WALL FINISH/FRAMING AND DEMO (E) PIPING, TYP. THROUGHOUT
AutoCAD SHX Text
REMOVE ALL (E) FLOOR AND WALL TILE THROUGHOUT TYP.
AutoCAD SHX Text
REMOVE WALL FINISH/FRAMING AND DEMO (E) PIPING, TYP. THROUGHOUT
AutoCAD SHX Text
HATCHED AREA NIC
AutoCAD SHX Text
REMOVE (E) HVAC GRILLES TYP. THROUGHOUT
AutoCAD SHX Text DEMOLITION NOTES 1) CARE SHALL BE TAKEN IN ORDER TO IDENTIFY AND CARE SHALL BE TAKEN IN ORDER TO IDENTIFY AND PROTECT ALL EXISTING MECHANICAL, ELECTRICAL, PLUMBING, STRUCTURAL EXISTING CONDITION. 2) REMOVE ALL ABANDONED M.E.P. SYSTEMS. REMOVE ALL ABANDONED M.E.P. SYSTEMS. 3) WHEN M.E.P. SYSTEMS ARE REMOVED FROM AN EXISTING WHEN M.E.P. SYSTEMS ARE REMOVED FROM AN EXISTING WALL OR CEILING WHICH IS TO REMAIN, PATCH ABANDONED OPENINGS TO MATCH EXISTING FINISH. 4) ALL EXISTING LIFE SAFETY DEVICES MUST REMAIN IN ALL EXISTING LIFE SAFETY DEVICES MUST REMAIN IN OPERATION.
AutoCAD SHX Text
REMOVE (E) DOOR, FRAME HARDWARE & THRESHOLD
AutoCAD SHX Text
REMOVE (E) DOOR, FRAME HARDWARE & THRESHOLD
AutoCAD SHX Text
REMOVE (E) DOOR, FRAME HARDWARE & THRESHOLD
AutoCAD SHX Text
REMOVE ALL (E) CEILING TILE AND GRID THROUGHOUT
AutoCAD SHX Text
(E) UTILITY CLOSETUTILITY CLOSET
AutoCAD SHX Text
HATCHED AREA NIC
AutoCAD SHX Text
REMOVE ALL (E) HVAC DIFFUSERS TYP. THROUGHOUT
AutoCAD SHX Text
REMOVE ALL (E) HVAC DIFFUSERS TYP. THROUGHOUT
AutoCAD SHX Text
REMOVE (E) HVAC GRILLES TYP. THROUGHOUT
AutoCAD SHX Text
PROTECT & MAINTAIN SPRINKLER SYSTEM THROUGHOUT TYP.
AutoCAD SHX Text
PROTECT & MAINTAIN SPRINKLER SYSTEM THROUGHOUT TYP.
AutoCAD SHX Text PROTECT & MAINTAIN MOTION DETECTOR FOR LIGHTING ADJUST LOCATION TO SO THAT IT DOES NOT INTERFERE WITH CEILING GRID.
AutoCAD SHX Text
PROTECT & MAINTAIN MOTION DETECTOR FOR LIGHTING
AutoCAD SHX Text
PROTECT & MAINTAIN FIRE ALARM SYSTEM THROUGHOUT TYP.
AutoCAD SHX Text
PROTECT & MAINTAIN FIRE ALARM SYSTEM THROUGHOUT TYP.
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
PROTECT (E) SOFFIT AND THRESHOLD
PROTECT (E) SOFFIT AND THRESHOLD
30x48"
CLEAR
FLOOR
SPACE
30x48"
CLEAR
FLOOR
SPACE
30x48"
CLEAR
FLOOR
SPACE
30x48"
CLEAR
FLOOR
SPACE
30x48"
CLEAR
FLOOR
SPACE
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF
A4 NEW FLOOR PLAN
194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
WOMEN'S RESTROOM
MEN'S RESTROOM
A4
ACCESSIBLE
UNISEX
RESTROOM
5'- 0"
5'- 0"
NEW FLOOR PLAN
1'-6"
1'-6"
5'-8" (5'-0" MIN.) 1'-6"
3'-1"
8'-0"
3'- 1"
3'-1" 1'-6"3'-1"3'-1"
EQ. EQ. EQ. EQ.
3'-0" EQ. EQ. EQ.
4'-51 2" 7'-
1"
6'-3" 2'-7"
2'-7"6'-3"
3'- 0"
1'-
2'- 0"
2'-
3'-
1"
09/02/24
3'- 3"
2'- 0"
2'-0" 3'-0"
2'-0" 3'-0"
2'- 0"
107A
A8
A8
A8
A8
A8
A8
A8
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:50:44 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text
HATCHED AREA NIC
AutoCAD SHX Text
(N) SERVICE MOP BASIN
AutoCAD SHX Text
(N) WALL MOUNTED SINK
AutoCAD SHX Text
HATCHED AREA NIC
AutoCAD SHX Text NOTES 1. CHECK (E) CONCRETE FLOORS FOR ABAAS SLOPE COMPLIANCE. CHECK (E) CONCRETE FLOORS FOR ABAAS SLOPE COMPLIANCE. GRIND AND FILL (E) FLOOR AS REQUIRED TO MEET ABAAS REQUIREMENTS THROUGHOUT, TYP 2. (N) FLOOR DRAIN TO HAVE ABAAS COMPLIANT GRATE, TYP. (N) FLOOR DRAIN TO HAVE ABAAS COMPLIANT GRATE, TYP. 3. RESINOUS FLOORING WITH 4” INTEGRAL BASE, TYP. THROUGHOUT RESINOUS FLOORING WITH 4” INTEGRAL BASE, TYP. THROUGHOUT INTEGRAL BASE, TYP. THROUGHOUT AREA OF (N) WORK. 4. INSTALL RESINOUS FLOORING PER MFR'S INSTALLATION INSTALL RESINOUS FLOORING PER MFR'S INSTALLATION INSTRUCTIONS. 5. WALL-MOUNTED STAINLESS STL 3'-0" W. MOP AND BROOM WALL-MOUNTED STAINLESS STL 3'-0" W. MOP AND BROOM HOLDER WITH UTILITY SHELF. COORDINATE LOCATION WITH PARK STAFF. 6. (N) PROVIDE (N) SIGN ON EXTERIOR OF DOOR THAT READS (N) PROVIDE (N) SIGN ON EXTERIOR OF DOOR THAT READS DIAPER CHANGING STATION INSIDE, COORDINATE LOCATION WITH PARK STAFF. 7. CONTRACTOR TO PROVIDE COLOR SAMPLES OF ALL FINISHES FOR CONTRACTOR TO PROVIDE COLOR SAMPLES OF ALL FINISHES FOR CO/COR TO SELECT FROM.
AutoCAD SHX Text
AutoCAD SHX Text A6
AutoCAD SHX Text
AutoCAD SHX Text A7
AutoCAD SHX Text
AutoCAD SHX Text A7
AutoCAD SHX Text
AutoCAD SHX Text A6
AutoCAD SHX Text
AutoCAD SHX Text A7
AutoCAD SHX Text
AutoCAD SHX Text A7
AutoCAD SHX Text
AutoCAD SHX Text A6
AutoCAD SHX Text
AutoCAD SHX Text A6
AutoCAD SHX Text
AutoCAD SHX Text A7
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
3'-0" DOOR
AutoCAD SHX Text
EXISTING WALLS
AutoCAD SHX Text
5'-0" DIAM CIRCLE
AutoCAD SHX Text
UTILITY CLOSET
AutoCAD SHX Text
(E) LEAVE LEGACY TILE AND PAINT TO MATCH NEW WORK
AutoCAD SHX Text
RECESSED SHELF SEE DETAIL 1/A9
AutoCAD SHX Text
DOOR (E) NIC
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text
(N) FULL HEIGHT WALL WITH BLOCKING OVER EXISTING WALL
AutoCAD SHX Text A7
AutoCAD SHX Text
AutoCAD SHX Text
(N) COATHOOK TYP., MOUNT ON COATHOOK TYP., MOUNT ON BACK OF PARTITION(S) 62" A.F.F.
AutoCAD SHX Text
(N) COATHOOK, MOUNT ON COATHOOK, MOUNT ON WALL JUST BELOW ACCENT COURSE NO HIGHER THAN 48" A.F.F.
AutoCAD SHX Text
(N) FULL HEIGHT WALLS SEE DETAIL 9/A8
AutoCAD SHX Text
(N) URINAL SCREEN
(N) URINAL SCREEN
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF
A5 NEW REFLECTED CEILING
194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
A5
1 NEW REFLECTED CEILING PLAN
09/01/24
LIGHT SCHEDULE
TYPE DESCRIPTION FINISH NOTES
F-1 2x2 LED TROFER 40W, 4400 LUMENS | ADJ. CCT WHITE
F-2 METALLIC GRAY
F-3
ON/OFF SWITCH WITH OCCUPANCY SENSORS (KEYED SWITCHED -OVERRIDE)
WHITE
BASIS OF DESIGN MANUF & MODEL
INTERIOR LINEAR LIGHT
INTERIOR RECESSED ROUND LIGHT
INTERIOR SURFACE LIGHT PROGRESS LIGHTING 5" LED FLUSH MOUNT CT FIXTURE
LITHONIA LIGHTING 6” LED REC CT BAFFLE MODULE ON/OFF SWITCH WITH OCCUPANCY SENSORS (KEYED SWITCHED -OVERRIDE)
ON/OFF SWITCH WITH OCCUPANCY SENSORS (KEYED SWITCHED -OVERRIDE)
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:51:05 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text
WOMEN'S RESTROOM
AutoCAD SHX Text
MEN'S RESTROOM
AutoCAD SHX Text
(N) SURFACE MOUNTED LUMINAIRE SURFACE MOUNTED LUMINAIRE F-2, TYP.,
AutoCAD SHX Text
(N) 2X2 DROP IN CEILING TILE 2X2 DROP IN CEILING TILE @ 8'-2" AFF
AutoCAD SHX Text
(N) LED LIGHT LED LIGHT FIXTURE F-1, TYP.
AutoCAD SHX Text STD. 24 IN. X 24 IN. 24 IN. X 24 IN. DROP CEILING AIR VENT REGISTER, TYP., WHITE TYP., WHITE WHITE
AutoCAD SHX Text
HATCHED AREA NIC
AutoCAD SHX Text
NOTES 1. SEE SHEET A8 FOR CEILING DETAILS.SEE SHEET A8 FOR CEILING DETAILS.
AutoCAD SHX Text
(N) 2X2 DROP IN CEILING TILE @ 8'-2" AFF2X2 DROP IN CEILING TILE @ 8'-2" AFF
AutoCAD SHX Text
UTILITY CLOSET
AutoCAD SHX Text
HATCHED AREA NIC
AutoCAD SHX Text
(N) PLACE RUNNER AND CROSS TEE FRAMEWORK TO SUPPORT LIGHTS, PLACE SINGLE TILE ABOVE SINK FOR LED RECESSED, LIGHT OTHERWISE LEAVE WITHOUT PANELS
AutoCAD SHX Text
(E) FIRE SUPPRESSION SYSTEM
AutoCAD SHX Text
(N) SURFACE MOUNTED LUMINAIRE F-2, TYP.
AutoCAD SHX Text
(N) LED LIGHT FIXTURE F-1, TYP.
AutoCAD SHX Text STD. 24 IN. X 24 IN. 24 IN. X 24 IN. DROP CEILING AIR VENT REGISTER, TYP., WHITE TYP., WHITE WHITE
AutoCAD SHX Text
(N) SOFFIT @ 8'-0" AFFSOFFIT @ 8'-0" AFF
AutoCAD SHX Text
(N) SOFFIT @ 7'-0" AFFSOFFIT @ 7'-0" AFF
AutoCAD SHX Text
(N) SOFFIT @ 7'-0" AFFSOFFIT @ 7'-0" AFF
AutoCAD SHX Text
(N) 2X2 DROP IN CEILING 2X2 DROP IN CEILING TILE @ 8'-0" AFF
AutoCAD SHX Text
(E)SPRINKLER HEAD
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
(N) SURFACE MOUNTED SURFACE MOUNTED LUMINAIRE, F-3, TYP.
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text
SURFACE MOUNTED LED EXIT SIGN, RED LETTERS, UNIVERSAL MOUNT, WHITE.
AutoCAD SHX Text
SURFACE MOUNTED LED EXIT SIGN, RED LETTERS, UNIVERSAL MOUNT, WHITE.
AutoCAD SHX Text
ACCESSIBLE UNISEX RESTROOM
ACCESSIBLE UNISEX RESTROOM
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF
A6 INTERIOR ELEVATIONS
SHEET 1 OF 2
194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
SOUTH WALL WOMEN'S RESTROOM
WALL RESTROOMENTRY
A6
2 EAST WALL WOMEN'S RESTROOM
A6
A6
A6
A6
1 ACCESSIBLE UNISEX RESTROOM
EAST WALL MEN'S RESTROOM
A6
09/02/24
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:51:01 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text 2'-8"
AutoCAD SHX Text 1'-4"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 1'-4 "12"
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text
UNISEX
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
MEN
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text
KEY NOTES
AutoCAD SHX Text 4"
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text
NOTE: PROVIDE BLOCKING IN WALLS AT ALL WALL MOUNTED ITEMS.
AutoCAD SHX Text
RECESSED SHELF SEE DETAIL 1/A9
AutoCAD SHX Text 96'-0"
AutoCAD SHX Text 3'-1"
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 1 BABY CHANGING STATION 2 ACCESS PANEL 3 TILE TYPE 3 TYP. 4 TILE TYPE 4 TYP. 5 TILE TYPE 5 TYP. 6 TOILET ACCESSORY: ELEC. HAND DRYER TYP. 7 TOILET ACCESSORY: SANITARY NAPKIN DISPENSER 8 TOILET ACCESSORY: TOILET ROLL DISPENSER TYP. 9 TOILET ACCESSORY: GRAB BAR TYP. 10 TOILET ACCESSORY: SANITARY NAPKIN DISPOSAL TYP. 11 TOILET ACCESSORY: SOAP DISPENSER TYP. 12 TOILET ACCESSORY: MIRROR 13 SIGNAGE 14 TOILET ACCESSORY: SEAT COVER DISPENSER 15 TOILET PARTITION TYP. 16 WALL-MOUNT URINAL TYP. 17 WALL-MOUNT WATER CLOSET TYP. 18 MOTION SENSOR 19 PAINT TYPE 1 TYP. 20 SERVICE MOP BASIN 21. MOP BASIN FAUCET 22. WALL MOUNTED SINK 23. TOUCHLESS FAUCET 24. URINAL SCREEN 25. WASTEBASKET 26. COATHOOK TYP.
1 BABY CHANGING STATION 2 ACCESS PANEL 3 TILE TYPE 3 TYP. 4 TILE TYPE 4 TYP. 5 TILE TYPE 5 TYP. 6 TOILET ACCESSORY: ELEC. HAND DRYER TYP. 7 TOILET ACCESSORY: SANITARY NAPKIN DISPENSER 8 TOILET ACCESSORY: TOILET ROLL DISPENSER TYP. 9 TOILET ACCESSORY: GRAB BAR TYP. 10 TOILET ACCESSORY: SANITARY NAPKIN DISPOSAL TYP. 11 TOILET ACCESSORY: SOAP DISPENSER TYP. 12 TOILET ACCESSORY: MIRROR 13 SIGNAGE 14 TOILET ACCESSORY: SEAT COVER DISPENSER 15 TOILET PARTITION TYP. 16 WALL-MOUNT URINAL TYP. 17 WALL-MOUNT WATER CLOSET TYP. 18 MOTION SENSOR 19 PAINT TYPE 1 TYP. 20 SERVICE MOP BASIN 21. MOP BASIN FAUCET 22. WALL MOUNTED SINK 23. TOUCHLESS FAUCET 24. URINAL SCREEN 25. WASTEBASKET 26. COATHOOK TYP.
A7 INTERIOR ELEVATIONS
SHEET 2 OF 2
194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
1008DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF
A7
4 MEN'S RESTROOM NORTH WALL
A7
1 WOMEN'S RESTROOM NORTH WALL
A7
5 SOUTH WALL MEN'S RESTROOM
A7
3 MEN'S RESTROOM EAST WALL
A7
2 JANITOR WEST WALL
09/02/24
A7
6 WEST WALL - ENTRY AREA
A7
7 TILE DETAIL
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:50:49 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text
MODELNUMBER
AutoCAD SHX Text
TRADENAME
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text
KEY NOTES
AutoCAD SHX Text
RECESSED SHELF SEE DETAIL 1/A9
AutoCAD SHX Text
NOTE: PROVIDE BLOCKING IN WALLS AT ALL WALL MOUNTED ITEMS.
AutoCAD SHX Text 72'-0"
AutoCAD SHX Text
MATCH TO EXISTING SOFFIT AND APPLY NEW PAINT ON ENTIRE AREA
AutoCAD SHX Text
ENSURE THRESHOLD MEETS ACCESSIBILITY STANDARDS.
AutoCAD SHX Text 4'-4"
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text 4"
AutoCAD SHX Text
ONE ROW OF ALTERNATING TILES 45° DIAGONAL CUT FOR TILES 3 & 4
1 BABY CHANGING STATION 2 ACCESS PANEL 3 TILE TYPE 3 TYP. 4 TILE TYPE 4 TYP. 5 TILE TYPE 5 TYP. 6 TOILET ACCESSORY: ELEC. HAND DRYER TYP. 7 TOILET ACCESSORY: SANITARY NAPKIN DISPENSER 8 TOILET ACCESSORY: TOILET ROLL DISPENSER TYP. 9 TOILET ACCESSORY: GRAB BAR TYP. 10 TOILET ACCESSORY: SANITARY NAPKIN DISPOSAL TYP. 11 TOILET ACCESSORY: SOAP DISPENSER TYP. 12 TOILET ACCESSORY: MIRROR 13 SIGNAGE 14 TOILET ACCESSORY: SEAT COVER DISPENSER 15 TOILET PARTITION TYP. 16 WALL-MOUNT URINAL TYP. 17 WALL-MOUNT WATER CLOSET TYP. 18 MOTION SENSOR: DIRECT TOWARD DOORWAY, TYP. 19 PAINT TYPE 1 TYP. 20 SERVICE MOP BASIN 21. MOP BASIN FAUCET 22. WALL MOUNTED SINK 23. TOUCHLESS FAUCET 24. URINAL SCREEN 25. WASTEBASKET 26. COATHOOK TYP.
1. MULTIPLE LAYERS OF DRYWALL TO BE APPLIED
WITH STAGGERED JOINTS
2. PROVIDE WATER RESISTANT GREEN BOARD GYPSUM
BOARD AT TOILET ROOMS AND JANITOR CLOSETS
AND OTHER SIMILAR 'WET' SPACES.
3. AT PARTITIONS SCHEDULED TO RECEIVE WALL TILE
FINISH PROVIDE CEMENTITIOUS BACKER BOARD.
4. COORDINATE DIMENSIONAL LAYOUT WITH APPLIED
FINISH THICKNESS WHERE CLEAR OR MINIMUM
CLEAR DIMENSIONS ARE REQUIRED. MAINTAIN CODE
REQUIRED CLEARANCES AT ALL APPLIED FINISHES.
5. METAL STUDS SHALL BE SPACED 16" O.C.
U.O.N. OR REQUIRED TO COMPLY WITH MAX.
DEFLECTION CRITERIA PER SPECIFICATIONS.
2" MAX.
#12 GAGE HANGER WIRE,
4' EACH WAY PLUS ONE
WIRE AT EA CORNER OF
LIGHT FIXTURES
LIGHT SHALL BE ATTACHED
TO THE CEILING SYSTEM
WITH POSITIVE CLAMP
DEVICES
LIGHT FIXTURE
#12 GAGE HANGER AT
EACH CORNER
RIGID STEEL HEAVY DUTY EMT
CONDUIT STRUT. @ 12'-0" O.C. EA.
WAY. START 6'-0" MAX FROM EDGE
OF CEILING AROUND PERIMETER
WIRE LOCKING PIN TO FASTEN
CROSS RUNNER TO MAIN
4- #12 GA SEISMIC SPLAY WIRE ONE
EACH WAY IN PLANE OF OF EACH
MAIN RUNNER - VERTICAL ANGLE OF
45° - ALL WIRES SECURED TO MAIN
RUNNER WITHIN 3" OF INTERSECTION
AT EA. END OF SPLAY WIRE THRU
HOLE IN RUNNER, CONDUIT STRUT
OR THRU EYE SCREW & TWISTING
WIRE TIGHT AROUND ITSELF AT
LEAST THREE COMPLETE TURNS IN
1-1/2" TYP.
CROSS TEE
1"DIA. X 20GA EMT STEEL CONDUIT
WHER "L" IS GREATER THAN 5'-6" -
3/4" DIA. 22 GA. EMT STEEL CONDUIT
STRUT UP TO "L" OF 5'-6". SLIP OVER
#12 GA. IN PLACE VERTICAL WIRE.
CUT TO FIT AND SHIM TIGHT TO
FLOOR OR ROOF STRUCTURE AND
MAIN RUNNER
45°
MAIN TEE (HEAVY DUTY)2"MAX
WHERE "L" IS GREATER THAN 8'-6"
AND LESS THAN 17'-0" ADD (4) SPLAY
WIRES AT MID HEIGHT OF STRUT.
LATERAL FORCE BRACING
3 FULL TURNS MIN.
HEAVY DUTY SYSTEM
1.) CEILING OVER 1,000SF REQUIRE HORIZONTAL RESTRAINT SYSTEM.
2.) CEILING WITHOUT RIGID BRACING MUST HAVE 2" OVERSIZED TRIM
RINGS FOR SPRINKLERS AND OTHER PENETRATIONS.
TOTAL SUSPENDED CEILING AREA
NOTE:
< 1000SF. LATERAL RESTRAINT
SYSTEM NOT REQUIRED PER ASCE
7-05 - 13.5.6.2.2 EXCEPTION C.
SECURE ALL WIRES TO
TEES MAXIMUM 2" FROM
INTERSECTION
NO. 12 GA. VERT. WIRE
HANGER IN COMPRESSION TUBE
- LEVEL CEILING GRID PRIOR
TO SETTING CONDUIT
45°
45°
45°
2"MAX
8" MAX.
3/4" CLR.
8" MAX.
3/4" CLR.7/8" BERC
2 CLIP
PERIMETER MEMBER
AT STARTER WALLS AT OPPOSITE WALLS
7/8" BERC
2 CLIP
MINIMUM
CLEARANCE
RUNNERS AT WALLS
IF LIGHT FIXTURE IS LESS
THAN 56 LBS. & 4-#12 GA.
IF LIGHT FIXTURE EXCEEDS
APPROVED HANGERS
PROVIDE 2-#12 GA. HANGERS
56 LBS. IT SHALL BE
SUPPORTED FROM THE
STRUCTURE ABOVE BY
0'-0"
A8
4" RESINOUS FLOORING BASE
SUSPENDED CEILING
PER 5-6/A8
FULL HT. W/ 20GA. 3 5/8"
METAL STUDS @ 16" O.C.
WITH SOUND BATT
INSULATION
BLOCKING @ 8'-0" A.F.F.
8'-0"
EXISTING CONCRETE SLAB
EXISTING
STRUCTURE
ABOVE
C O
N
TR
AC
TO
R
TO
V
ER
IF
Y
EXIST.
STRUCTURE
ABOVE
A8
5/8" GWB , MUD AND PAINT
ATTACH EXIST. METAL DECK
w/ #8 METAL SCREWS FASTENERS @ 16"oc
DEFLECTION TRACK @ FULL HEIGHT
PARTITIONS - SEAL ALL VOIDS & GAPS
CEILING RUNNER 25MSG MIN. GALV.
STL. w/ 3" OR 4" LEGS OFFSET @
MIDPOINT 5/8"
METAL STUDS @ 16"oc 20 GA. -
TO UNDERSIDE OF STRUCTURE
ACOUSTIC INSULATION (PROVIDE
ACOUSTIC SEALANT @ TOP TRACK -
BOTH SIDES)
GYPSUM WALL BOARD TYP.
READY FOR PAINT
ACOUSTIC INSULATION (PROVIDE
ACOUSTIC SEALANT @ BOTTOM
4" RESINOUS FLOORING - TYP.
SEALANT - ALL VOIDS
FIRE SEAL, TYP.
3/ 4"
G
AP 1
1/
4" M
IN
O
VE
R
LA
P
3/ 4"
EXIST. MTL. DECK
ATTACH w/ 1" RAMSET 1508
POWER ACTUATED FASTENERS
@ 16"oc @ CONCRETE
EXIST. CONCRETE
SUBFLOOR
MTL. STUD BASE TRACK, TYP.
5/8" G.W.B. EA. SIDE,
ALTERNATE TAPE & MUD
CEILING RUNNER 25MSG MIN. GALV.
STL. W/ 3" OR 4" LEGS OFFSET @
MIDPOINT 5/8"
2X4 STUDS @ 16" O.C.
TO UNDERSIDE OF STRUCTURE
ACOUSTIC INSULATION (PROVIDE
ACOUSTIC SEALANT @ TOP TRACK -
BOTH SIDES)
5/8" GYPSUM WALL BOARD TYP.
READY FOR PAINT
ACOUSTIC INSULATION (PROVIDE
ACOUSTIC SEALANT @ BOTTOM
4" RESINOUS FLOORING - TYP.
SEALANT TYP.
3/ 4"
G
AP
1/
4" M
IN
O
VE
R
LA
P
3/ 4"
GWB
CEILING LINE +8'-0"
20 GA METAL DEFLECTION TRACK
@ FULL HEIGHT PARTITIONS - SEAL
ALL VOIDS & GAPS
ATTACH TO JOISTS W/ (2) #8
SCREW FASTENERS @ 16"OC
0'-0"
2x12 JOISTS
ATTACH METAL TRACK TO
CONCRETE FLOOR WITH
0.145 DIA. HILTI POWER
ACTUATED ANCHORS @ MIN.
2'-0" O.C. (ICBO ER-2388)
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF
A8
WALL AND CEILING DETAILS
194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
A8
3 TYPICAL WALL BLOCKING
A8
4 TOILET PARTITION AT WALL
A8
1 ACCESSIBLE SINK SECT
M. KERR
A8
2 WALL DETAIL
A8
7 SOFFIT @ TRANSITION
A8
6 TYPICAL CEILING BRACING DETAIL
A8
5 LIGHT FIXTURE BRACING DETAIL
A8
10 TYPICAL WALL HEAD DEFLECTION
A8
A8
8 TYPICAL WALL AT SOFFIT
SCALE: 1 12"= 1'-0"SCALE: 1 12"= 1'-0"
TYPICAL FULL HEIGHT WALL
09/02/24
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:50:56 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text
SHEET NOTES
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text
INSULATE EXPOSED PIPES
AutoCAD SHX Text 2'-3"
AutoCAD SHX Text 9"
AutoCAD SHX Text 8"
AutoCAD SHX Text 11"
AutoCAD SHX Text
17" MIN
AutoCAD SHX Text
WALL-MOUNTED SINK, SEE
AutoCAD SHX Text
FIXTURE SCHEDULE
AutoCAD SHX Text
REQUIRED KNEE
AutoCAD SHX Text
CLEARANCE AT ACCESSIBLE
AutoCAD SHX Text
SINK
AutoCAD SHX Text
40" MAX A.F.F.
AutoCAD SHX Text
40" MAX A.F.F.
AutoCAD SHX Text
TO REFLECTIVE SURFACE OF MIRROR
AutoCAD SHX Text
TILT-MIRROR, SEE
AutoCAD SHX Text
ACCESSORIES SCHEDULE
AutoCAD SHX Text
BLOCKING TYP.
AutoCAD SHX Text
WALL-MOUNTED SINK CARRIER
AutoCAD SHX Text
(E) 2X12 ROOF RAFTER, WHERE OCCURS
AutoCAD SHX Text
(N) 5/8" GYP. BD. CLG.
AutoCAD SHX Text
(E) 2X4 CEILING JOISTS @ 16" O.C., FILL W/ (N) MIN. R-11 BATT INSUL.
AutoCAD SHX Text
(N) 1/4" SEALANT OVER BACKER ROD, TYP.
AutoCAD SHX Text
(E) WALL
AutoCAD SHX Text
(N) INTER. FINISH, SEE INTER. ELEVS.
AutoCAD SHX Text
WALL ASSEMBLY AS SCHEDULED
AutoCAD SHX Text
A34 CLIP EACH END, TOP AND BOTTOM
AutoCAD SHX Text
* 4X BLOCKING TO MATCH STUD FRAMING WIDTH
AutoCAD SHX Text
* PROVIDE 4X BLOCKING AT ALL WALL MOUNTED
AutoCAD SHX Text
ITEMS WEIGHING MORE THAN 50 LBS
AutoCAD SHX Text
(2) #6 X 3" SCREW TO 4X4 BLOCKING,
AutoCAD SHX Text
TYP EACH LOCATION
AutoCAD SHX Text
ANGLE BRACKET
AutoCAD SHX Text
PARTITION PANEL
AutoCAD SHX Text
BLOCKING AS REQUIRED
AutoCAD SHX Text
#12 X 2 1/2" SMS
AutoCAD SHX Text
WALL PARTITION PER DETAIL
AutoCAD SHX Text
5/8" GYP. BOARD
AutoCAD SHX Text
3 5/8" METAL STUDS @ 16" O.C. (MAX.)
AutoCAD SHX Text
3" SOUND ATTENUATION BLANKETS
AutoCAD SHX Text
ACOUSTICAL SEALANT AT TOP & BOTT. OF WALL
TO U.S.D. STC 49
A9 SCHEDULES
194369
NEZ PERCE NATIONAL HISTORICAL PARK
M. KERR
M. KERR
193561
1010DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
CADD:
OF09/02/24
PT-1 PAINT MATCH EXISTING
T-3
T-4 TILE DALTILE
MATERIAL BASIS OF DESIGN
MANUFACTURER MODEL / STYLE COLOR/FINISH SIZE REMARKS
INTERIOR FINISH SCHEDULE
ROOM FINISH SCHEDULE
ROOM NO. ROOM NAME FLOOR FINISH REMARKS
110 ALCOVE EPOXY
109 ACCESSIBLE
UNISEX
RESTROOM
EPOXY
DOOR SCHEDULE
DOOR ROOM
NAME (E)/(N)
TYP
E
OPENING DOOR FRAME HW
GROUP RATING REMARKWIDTH HEIGHT THICK MAT FINISH MAT PUSH PULL
A UNISEX (N) A 3' - 0" 7' - 0" 1 3/8" WD PT-1 MTL PT-1 PT-1 01 NR
B JANITOR (N) A 3' - 0" 7' - 0" 1 3/8" WD PT-1 MTL PT-1 PT-1 01 NR
BABY CHANGING TABLE KOALA KARE KB300-01SS GRAY
ELECTRIC HAND DRYER EXCEL XLERATOR XL-BLW BRUSHED NICKEL
SANITARY NAPKIN DISPOSAL BOBRICK B-270 SATIN FINISH STAINLESS STEEL
TILT MIRRORS BOBRICK B-293 2436 SATIN FINISH STAINLESS STEEL 24 X 36 IN
CLOTHES HOOK BOBRICK B-7672 SATIN FINISH STAINLESS STEEL INSTALL ON TOILET PARTITION...
SOAP DISPENSER BOBRICK B-818615 SATIN FINISH STAINLESS STEEL
GRAB BARS BOBRICK B-6806 SATIN FINISH STAINLESS STEEL
TOILET PAPER DISPENSER BOBRICK B-4288 CONTURA SERIES SATIN FINISH STAINLESS STEEL
TOILET PARTITION BOBRICK DURA LINE 1082.67 OVERHEAD-BRACED SAND 414-SEI SOLID PHENOLIC LAMINATE PANELS
W/ INSTITUTIONAL HARDWARE
TOILET FLUSHOMETER SLOAN REGAL 111XL 1.6 GAL
FLOOR-MTD TOILET AMERICAN STD WALL-HUNG AFWALL MILLENNIUM 1.1-1.6 GPF 16.5 IN
HIGH ELONGATED TOP SPUD FLUSHOMETER WHITE
SINK FAUCET CENTRAL BRASS 0355 POLISHED CHROME
WALL-MTD SINK TRUEFORM 72" ADA FLOATING CONCRETE RAMP SINK STORM 2 WIDESPREAD FAUCET HOLES
ITEM BASIS OF DESIGN
MANUFACTURER MODEL / STYLE COLOR/FINISH REMARKS
FIXTURES & ACCESSORIES SCHEDULE
WALL-MTD SINK AMERICAN STD LUCERNE 0356.041 WHITE SINGLE HOLE
AMERICAN STD NEXTGEN SELECTRONIC® TOUCHLESS FAUCET,
BASE MODEL, 0.5 GPM/1.9 LPM BRUSHED NICKELSINK FAUCET
POWER KITS MUST BE PURCHASED
SEPARATELY.
REUSE EXISTING
MIRRORS 3 X 6 FT
108 WOMAN'S EPOXY
107 MEN'S EPOXY
107A UTILITY CLOSET EPOXY
WALL PAINT
PT-1
PT-1
PT-1
PT-1
PT-1
TILE FINISH
T-4,3,5
T-4,3,5 T-4,3,5
FLOOR EPOXY
FARRIER BLUE ROAN -FA59 5 X 5 X 5/16IN
CUSTOM BUILDING PRODUCTS
T-5 DALTILE
TILE
TILE GROUT
TILE
DALTILE 5 X 5 X 5/16IN
5 X 5 X 5/16IN
GRULLO -FA60
PALOMINO -FA58
FARRIER
FARRIER
643 WARM GRAYSEE SPECS COORDINATE FINAL COLOR
WITH OWNER
EVERLAST EPOXY SYSTEMS ECO-FRIENDLY FLOOR LIGHT TEAL
A10
1 SHELF DETAIL
URINAL AMERICAN STD WALL HUNG FLOWISE WASHOUT TOP SPUD URINAL WHITE
C:\Users\mekerr\OneDrive - DOI\___Admin items for sharing__Public\Current Projects Update\NEPE - update folder\NEPE_V16.dwg, 9/16/2024 11:50:37 AM, _AutoCAD PDF (General Documentation).pc3
AutoCAD SHX Text 1'-4"
AutoCAD SHX Text 3'-10"
AutoCAD SHX Text 2'-7"
AutoCAD SHX Text 2'-9"
AutoCAD SHX Text
2" CONCRETE COUNTERTOP MATCH COLOR TO RAMP SINK
AutoCAD SHX Text SOFFIT 20GA.3 5/8" METAL STUD 20GA.3 5/8" METAL STUD BLOCKING AS REQUIRED COVERED IN 5/8" GWB. COVERED IN 5/8" GWB. 5/8" GWB.
AutoCAD SHX Text
20GA. 3 5/8" METAL STUD BLOCKING AS REQUIRED COVERED IN 5/8" GWB. 5/8" GWB.
AutoCAD SHX Text
MATCH ADJACENT FINISHES
ASSEMBLY(S) SHALL TIE INTO WALL BLOCKING
| Sheets and Views |
| NEPE_V16-Model |
| NEPE_V16-Cover Sheet |
| NEPE_V16-Accessible Details |
| NEPE_V16-Demo |
| NEPE_V16-Demo Ceiling Plan |
| NEPE_V16-New Floor Plan |
| NEPE_V16-New Reflected Ceiling |
| NEPE_V16-Interior Elevations |
| NEPE_V16-Interior Elevations (2) |
| NEPE_V16-DETAILS |
| NEPE_V16-SCHEDULES |
File details come from the government source that posted it. Updated .