SHEET

DRAWING NO.

PKG. NO.

UNITED STATES

DEPARTMENT OF THE INTERIOR

NATIONAL PARK SERVICE

HACE OF

NAME OF PARK

LOCATION WITHIN PARK

REGION COUNTY STATE

TITLE OF DRAWINGREVISIONMARK SHEET DATE INITA/E FIRM

SAGAMORE HILL NATIONAL HISTORIC SITE

THEODORE ROOSEVELT HOUSE

CONSTRUCTION DOCUMENTS REPAIR MASONRY FOUNDATION at THEODORE ROOSEVELT HOUSE

ONE NASSAU NEW YORK

168748

SAHI

251428

SAGAMORE HILL NATIONAL HISTORIC SITE

REPAIR MASONRY FOUNDATION at

THEODORE ROOSEVELT HOUSE

SAHI 251428

-- COVER SHEET

A-01 SITE PLAN; GENERAL NOTES; KEY; OPTION NO. 1 SCOPE

A-02 PART SOUTH & EAST ELEVATIONS - MASONRY REPAIRS

A-03 PART EAST & NORTH ELEVATIONS - MASONRY REPAIRS

A-04 PART NORTH ELEVATION - MASONRY REPAIRS

A-05 PART EAST ELEVATION - BLUESTONE MASONRY REPAIRS

A-06 PART NORTH & WEST ELEVATIONS - BLUESTONE MASONRY REPAIRS

LIST OF DRAWINGS

NATIONAL PARK SERVICE, HACE/PFCA

INTERIOR REGION 1,

NORTH ATLANTIC - APPALACHIAN

View of TRH from southwest, ca. 1885

Foundation wall at north elevation, 2019

JG

A-01

SITE PLAN; GENERAL NOTES; KEY;

OPTIONS SCOPE

05/07/20

REPAIR MASONRY FOUNDATION AT

THEODORE ROOSEVELT HOUSE

SAGAMORE HILL NATIONAL HISTORIC SITE 7

OPTION #1: RAKE AND REPOINT FOUNDATION WALL BENEATH PIAZZA -- NORTH ELEVATION1

A-01 NOT TO SCALE

A-01 NOT TO SCALE

A-01 NOT TO SCALE

OPTION #1: RAKE AND REPOINT FOUNDATION WALL BENEATH PIAZZA -- WEST AND SOUTH ELEVATIONS

OPTION #1: RAKE AND REPOINT FOUNDATION WALL BENEATH PIAZZA -- BENEATH MAIN ENTRANCE AREA SITE PLAN4 A-01

DRAWING NO.

SHEET

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET

OPTION #1: PROVIDE ADDITIONAL STONE MASONRY REPOINTING AS REQUIRED, BENEATH THE PIAZZA CONTRACT LINE ITEM (CLIN) 5A: RAKE OUT LOOSE, FRAGMENTED, FAILED AND/OR FRIABLE MORTAR JOINTS. REMOVE SOIL, BIOLOGICAL GROWTH, AND MISC. DEBRIS FROM SUBJECT JOINTS. DAMPEN JOINTS TO AVOID SUCTION AND PRELIMINARY DRYING. POINT JOINTS IN LIFTS, MATCHING EXISTING MORTAR COLOR, PROFILE AND TOOLING, TYPICAL. BRUSH OFF ANY EXCESS MORTAR. PERFORM FINAL CLEANING.

REMOVE MORTAR DROPPINGS, CONSTRUCTION DEBRIS AND PACKAGING.

ANTICIPATED TASKS INCLUDE MASONRY REPAIR TREATMENTS SIMILAR TO CATEGORIES &

PER THE DIAGRAMS ABOVE, ALLOW (FOR BIDDING PURPOSES) 55 LINEAL FEET (LF) OF REPOINTING NOT INCLUDED IN THE BASE-

BID.QUANTITIES AT RIGHT.

OF ___

168748

PMIS

251428

OPTION #2: SPECIALTY MASONRY ASSESSMENT AND REPAIR

CONTRACT LINE ITEM (CLIN) 6A: ALL WORK DESCRIBED IN CATEGORY AT RIGHT AND IN THE SPECIFICATIONS.

CONTRACT LINE ITEM (CLIN) 6B: ALL WORK DESCRIBED IN CATEGORY AT RIGHT AND IN THE SPECIFICATIONS.

STONE MASONRY: ESTIMATED 15 SF EXPOSED

AREA & 42 LF MORTAR JOINTS. ALLOW 10%

RAKE AND REPOINT = 4 LF.

STONE MASONRY: ESTIMATED 145 SF

EXPOSED AREA & 420 LF MORTAR JOINTS.

ALLOW 10% RAKE AND REPOINT = 42 LF.

STONE MASONRY: ESTIMATED 32 SF EXPOSED

AREA & 90 LF MORTAR JOINTS. ALLOW 10%

RAKE AND REPOINT = 9 LF.

FOUNDATION WALL MASONRY REPAIR TREATMENT KEY

REPOINT STONE-TO-STONE GRANITE MASONRY: RAKE OUT LOOSE, FRAGMENTED, FRIABLE,

AND OTHERWISE FAILED MORTAR JOINTS. REMOVE PLANT MATERIALS AND MISCELLANEOUS

DEBRIS. DAMPEN JOINTS TO AVOID EXCESSIVE “SUCTION” (RAPID DRYING). REPOINT IN

MULTIPLE LIFTS. TUCKPOINT WITH “GRAPEVINE” JOINTS, MATCHING INTACT ADJACENT

JOINTS IN COLOR, TEXTURE AND PROFILE, TYPICAL. WHEN “THUMBPRINT HARD,” REMOVE

EXCESS MORTAR. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

REPOINT STONE-TO-STONE AND STONE-TO-BRICK FOUNDATION WALL MASONRY JOINTS AT

GRADE: REPOINT WINDOW SILL PERIMETERS AS INDICATED. REPOINT BED JOINTS PER

CATEGORY “A” ABOVE. AT LOAD-BEARING WALLS, RAKE OUT AND REPOINT JOINTS IN

CONSECUTIVE SECTIONS NOT TO EXCEED 4’-0” AT A TIME.

BRICK MASONRY: FILL CRACKS AND HOLES GREATER THAN 1/16” IN WIDTH WITH RED-

TINTED MORTAR. WHEN “THUMBPRINT HARD,” REMOVE EXCESS MORTAR.

“DEAD” AND DELAMINATED MORTAR FILL: INSPECT VISIBLE MICRO-CRACKS IN MORTAR

JOINTS, VISUALLY AND BY "RINGING" WITH A SOFT-FACE (PLASTIC) OR MASON'S HAMMER.

POINT SOUND, INTACT JOINTS WITH GROUT. IF "DEAD" SOUND INDICATES VOIDS AND/OR

DELAMINATED MASONRY, REMOVE FAILED MORTAR, CLEAN JOINT AND REPOINT PER

CATEGORY “A” ABOVE.

INAPPROPRIATE EXISTING MORTAR AND/OR SEALANT: RAKE OUT INAPPROPRIATE MORTAR

AND URETHANE SEALANTS; REMOVE RESIDUE FROM JOINT SURFACES AND FACE OF STONE.

USING THE APPROPRIATE MORTAR MIX, REPOINT JOINTS PER CATEGORY “A” ABOVE.

BLUESTONE WATER TABLE MASONRY: AT BED AND HEAD JOINTS, RAKE OUT LOOSE,

FRAGMENTED, FRIABLE, AND OTHERWISE FAILED MORTAR. REMOVE PLANT MATERIALS AND

MISCELLANEOUS DEBRIS. DAMPEN JOINTS TO AVOID EXCESSIVE “SUCTION” (RAPID

DRYING). REPOINT IN MULTIPLE LIFTS. TUCKPOINT JOINTS, MATCHING INTACT ADJACENT

JOINTS IN COLOR, TEXTURE AND PROFILE, TYPICAL. REFER TO SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

PORTE-

COCHERE

PIAZZA

EA

S T

PO

R C H

DRIVEWAY

WEST LAWN

SOUTH LAWN

NORTH LAWN

ACCESSIBLE SIDEWALK

THEODORE ROOSEVELT HOUSE

R A M

P

CIRCLE

A

B

C

D

E

F

GENERAL MASONRY FOUNDATION REPAIR NOTES

1. HISTORIC PRESERVATION TREATMENT: THROUGHOUT THIS PROJECT,

INTACT EXISTING MATERIALS, INCLUDING RANDOM-COURSED AND

DRESSED STONE COMPONENTS AND SOUND AND INTACT MORTAR JOINTS,

SHALL BE RETAINED AND PRESERVED AS MUCH AS POSSIBLE.

2. EXISTING CONDITIONS: THESE DRAWINGS REPRESENT SCHEMATICALLY

THE EXISTING DETAILS AND CONDITIONS OBSERVED DURING THE TIME

OF FIELDWORK; CONTRACTOR SHALL DOCUMENT AND VERIFY ALL

CONDITIONS, DIMENSIONS AND PROFILES.

3. EXCLUSIONS:

a.ALL BRICK AND STONE MASONRY ABOVE AND INCLUDING THE BRICK

AND TERRA COTTA WATER TABLE.

b.ALL BRICK MASONRY ABOVE THE BLUESTONE ASHLAR WATER TABLE.

c. INTERIOR FACES OF NORTH AND EAST PORCHES.

4. SCOPE OF WORK: UNLESS OTHERWISE NOTED, ALL EXPOSED STONE

MASONRY, INCLUDING BRICK BASEMENT WINDOW SURROUNDS, SHALL

BE INSPECTED, AND OBSERVED CRACKS, HOLES, MISSING AND FAILED

JOINTS SHALL BE REPAIRED OR REPLACED. MATCH COLOR, TEXTURE AND

JOINT PROFILE OF INTACT, ADJACENT MORTAR.

5. CLOSEOUT: REMOVE MORTAR DRIPS AND MISCELLANEOUS

CONSTRUCTION DEBRIS FROM MASONRY ELEMENTS, BULKHEADS AND

LANDSCAPE FEATURES.

ALLOW FOR BIDDING PURPOSES:

20 LF (CUMULATIVE) OF STONE MASONRY

MORTAR JOINT REPAIR/REPLACEMENT

TREATMENT

100 LF (CUMULATIVE) OF STONE/STONE AND

STONE/BRICK MORTAR JOINT

REPAIR/REPLACEMENT TREATMENT

5 LF (CUMULATIVE) OF BRICK MASONRY

MORTAR JOINT TREATMENT

6 SF TOTAL OF STONE MASONRY MORTAR

JOINT REPAIR/REPLACEMENT TREATMENT

30 LF TOTAL OF QUARRY STONE AND

BLUESTONE MORTAR JOINT

REPAIR/REPLACEMENT TREATMENT

25 LF TOTAL OF BLUESTONE WATER TABLE

MASONRY MORTAR JOINT

REPAIR/REPLACEMENT TREATMENT

6 SF TOTAL OF STAIN REMOVAL TREATMENT

A B

D

E

A-02

PART SOUTH & EAST ELEVATIONS

MASONRY REPAIRS

05/07/20 7

REPAIR MASONRY FOUNDATION AT

THEODORE ROOSEVELT HOUSE

SAGAMORE HILL NATIONAL HISTORIC SITE

BRICK / STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

MASONRY AT BASEMENT WINDOW OPENING

NOT TO SCALE

A-02

MASONRY AT BASEMENT WINDOW OPENING

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

BRICK / STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

STONE MASONRY CHIMNEY FOUNDATION WALL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WAL

NOT TO SCALE

A-02

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-02

DRAWING NO.

PKG

NO. SHEET

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET

REMOVE DIRT, PLANT DEBRIS AND/OR FAILED MORTAR FROM STONE-

TO-STONE AND STONE-TO-BRICK JOINTS, TYPICAL. REPOINT JOINTS

BETWEEN STONE WINDOW SILLS AND BRICK JAMBS.

A02

A02

A02

A02

A02

A02

A02

A02

A02

A02

A02

A02

A02

A02

A02

A02

A02

A0214

A02

A02

REMOVE INAPPROPRIATE (e.g., INCORRECT MIX; POOR COLOR MATCH)

MORTAR AND MISC. DEBRIS. MOISTEN JOINTS. REPOINT IN LIFTS PER

THE SPECIFICATIONS. TUCKPOINT WITH "GRAPEVINE" JOINT PROFILE

TO MATCH EXISTING COLOR, TEXTURE AND DIMENSIONS, TYPICAL.

AT EXISTING HOLES, REMOVE DEBRIS AND PREPARE SUBSTRATE.

PATCH HOLES (IN LIFTS, AS REQUIRED), MATCHING EXISTING MORTAR

COLOR AND TEXTURE, TYPICAL.

AT EXISTING HOLES, REMOVE DEBRIS AND PREPARE SUBSTRATE.

PATCH HOLES (IN LIFTS, AS REQUIRED), MATCHING EXISTING MORTAR

COLOR AND TEXTURE, TYPICAL.

WHERE EXISTING MORTAR JOINTS ARE MISSING OR DISINTEGRATING

AT AND/OR JUST BELOW EXISTING GRADE LEVEL, REMOVE ORGANIC

MATTER AND MISCELLANEOUS DEBRIS. REPOINT IN LIFTS PER THE

SPECIFICATIONS. MATCH EXISTING MORTAR COLOR, TEXTURE AND

DIMENSIONS, TYPICAL.

REMOVE DEBRIS. REPOINT JOINTS BETWEEN STONE WINDOW SILLS

AND BRICK JAMBS, TYPICAL.

REMOVE DEBRIS. REPOINT JOINTS BETWEEN STONE WINDOW SILL

AND BRICK JAMB, TYPICAL.

WHERE EXISTING MORTAR JOINTS ARE MISSING, FRIABLE AND/OR

DISINTEGRATING, REMOVE MATERIAL AND MISCELLANEOUS DEBRIS.

REPOINT IN LIFTS PER THE SPECIFICATIONS. TUCKPOINT WITH

"GRAPEVINE" JOINT PROFILE TO MATCH EXISTING COLOR, TEXTURE

AND DIMENSIONS, TYPICAL.

AT EXISTING CRACKS RESULTING FROM

DETERIORATION OR MORTAR

SHRINKAGE, REMOVE DIRT AND PLANT

DEBRIS. REPOINT (IN LIFTS, AS

REQUIRED), MATCHING EXISTING

MORTAR COLOR AND TEXTURE, TYPICAL.

UNLESS EXISTING METAL HARDWARE IS RESULTING IN PHYSICAL

DAMAGE TO BUILDING STONES (e.g., FROM RUST EXPANSION), RETAIN

IN PLACE, TYPICAL. BRING ANY FRACTURED STONES TO THE

CONTRACTING OFFICER'S ATTENTION.

OF ___

NOTE THAT EXISTING EXTERIOR BRICK MASONRY (BRICKS AND

MORTAR) IS TYPICALLY PAINTED.

REMOVE DEBRIS BETWEEN STONE WINDOW SILL AND ADJACENT

BRICK/STONE WALL. PROVIDE BACKER ROD AS REQUIRED AT DEEP

GAPS. REPOINT IN LIFTS PER THE SPECIFICATIONS.

EXISTING CONDITIONS. EXISTING CONDITIONS. NOTE APPLICATION OF "GRAPEVINE"

PROFILE TO MASK AND VISUALLY MITIGATE EXCESSIVE WIDTH OF

CERTAIN MORTAR JOINTS.

PHOTO KEY

PHOTO KEY PHOTO KEY

B

B

E

B

B

A

A

A

A

B A

B

C

168748

A-03

PART EAST & NORTH ELEVATIONS

MASONRY REPAIRS

REPAIR MASONRY FOUNDATION AT

THEODORE ROOSEVELT HOUSE

SAGAMORE HILL NATIONAL HISTORIC SITE05/07/20

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

TYPICAL "GRAPEVINE" MORTAR JOINTS

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-03

A-03 NTS DRAWING NO.

PKG

NO. SHEET

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEETSUB SHEET NO.DESIGNED:DESIGNED:

A03 2 A03

A03

A03

A03

A03

A03

A03

A03 5A03

A03

A03

A0310

A03

A03

A03

A03

A03

A03

A03

A03

A04

WHERE EXISTING MORTAR JOINTS ARE MISSING OR DISINTEGRATING

AT AND/OR JUST BELOW EXISTING GRADE LEVEL, REMOVE ORGANIC

MATTER AND MISCELLANEOUS DEBRIS. REPOINT IN LIFTS PER THE

SPECIFICATIONS. MATCH EXISTING MORTAR COLOR, TEXTURE AND

DIMENSIONS, TYPICAL.

WHERE EXISTING MORTAR JOINTS ARE MISSING OR DISINTEGRATING

AT AND/OR JUST BELOW EXISTING GRADE LEVEL, REMOVE ORGANIC

MATTER AND MISCELLANEOUS DEBRIS. REPOINT IN LIFTS PER THE

SPECIFICATIONS. MATCH EXISTING MORTAR COLOR, TEXTURE AND

DIMENSIONS, TYPICAL.

AT ABOVE-GRADE MORTAR JOINTS TO BE RAKED OUT AND REPOINTED,

MATCH EXISTING MORTAR COLOR, TEXTURE AND DIMENSIONS, AND

MATCH "GRAPEVINE" PROFILE, TYPICAL. IN GENERAL, RECESS FACE

OF MORTAR JOINT TO AVOID CONCEALING STONE ARRISES; REMOVE

EXCESS MORTAR FROM FACE OF STONES.

WHERE EXISTING MORTAR IS CRACKED, FRAGMENTED, LOOSES AND/OR

FRIABLE, RAKE OUT AND PREP JOINTS. REPOINT IN MULTIPLE LIFTS PER

THE SPECIFICATIONS. MATCH EXISTING MORTAR COLOR, TEXTURE AND

"GRAPEVINE" PROFILE, TYPICAL.

OF ___

WHERE EXISTING MORTAR JOINTS ARE MISSING OR DISINTEGRATING

REMOVE ORGANIC MATTER AND MISCELLANEOUS DEBRIS. REPOINT IN

LIFTS PER THE SPECIFICATIONS. MATCH EXISTING MORTAR COLOR,

TEXTURE AND DIMENSIONS, TYPICAL.

WHERE EXISTING MORTAR JOINTS ARE MISSING OR DISINTEGRATING

AT AND/OR JUST BELOW EXISTING GRADE LEVEL, REMOVE ORGANIC

MATTER AND MISCELLANEOUS DEBRIS. REPOINT IN LIFTS PER THE

SPECIFICATIONS. MATCH EXISTING MORTAR COLOR, TEXTURE AND

DIMENSIONS, TYPICAL.

INSPECT VISIBLE MICRO-CRACKS IN MORTAR JOINTS, VISUALLY AND

BY "RINGING" WITH A SOFT-FACE (PLASTIC) OR MASON'S HAMMER.

POINT SOUND, INTACT JOINTS WITH GROUT. IF "DEAD" SOUND

INDICATES VOIDS AND/OR DELAMINATED MASONRY, REMOVE FAILED

MORTAR, CLEAN JOINT AND REPOINT IN LIFTS PER THE

SPECIFICATIONS, TYPICAL.

WHERE EXISTING MORTAR JOINTS ARE MISSING OR DISINTEGRATING

AT AND/OR JUST BELOW EXISTING GRADE LEVEL, REMOVE ORGANIC

MATTER AND MISCELLANEOUS DEBRIS. REPOINT IN LIFTS PER THE

SPECIFICATIONS. MATCH EXISTING MORTAR COLOR, TEXTURE AND

DIMENSIONS, TYPICAL.

AT JOINT BETWEEN STONE SLAB, REMOVE ORGANIC MATTER AND

MISCELLANEOUS DEBRIS. PROVIDE BACKER ROD AT DEEP GAPS.

REPOINT IN LIFTS PER THE SPECIFICATIONS, MATCHING EXISTING

MORTAR COLOR, TEXTURE AND DIMENSIONS, TYPICAL.FILL SMALL HOLES WITH MORTAR, MATCHING EXISTING MORTAR

COLOR, TEXTURE AND DIMENSIONS, TYPICAL.

REMOVE INAPPROPRIATE (i.e., WRONG COLOR, WRONG TOOLING)

MASONRY MORTAR AND SEALANT BEADS. PREPARE JOINT AND

REPOINT IN LIFTS PER THE SPECIFICATIONS. MATCH ADJACENT

MORTAR COLOR, TEXTURE AND DIMENSIONS, TYPICAL.

PHOTO KEY PHOTO KEY

A

B A

B B

B

D

B

B

B

B

EA

B

B

A A

B A B

D

D

D

A

B B

AB

E

E

D

B

E A

B A

E

D

A-04

PART NORTH ELEVATION

MASONRY REPAIRS

REPAIR MASONRY FOUNDATION AT

THEODORE ROOSEVELT HOUSE

SAGAMORE HILL NATIONAL HISTORIC SITE05/07/20

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

PART NORTH ELEVATION: STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE / BRICK MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

STONE MASONRY FOUNDATION WALL

NOT TO SCALE

A-04

DRAWING NO.

PKG

NO. SHEET

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET

A03

A04

A04 2 A04

A04

A04

A04

A04

A04

A04

A04

A04

A04

A03

A03

A03

OF ___

REMOVE DEBRIS BETWEEN STONE WINDOW SILL AND ADJACENT

BRICK/STONE WALL. REPOINT IN LIFTS PER THE SPECIFICATIONS.

PATCH HOLES IN BRICK MASONRY, WHERE INDICATED; MATCH

EXISTING BRICK MASONRY JOINT PROFILE, TYPICAL.

PHOTO KEY

B

A

B

A

B

A

B

B

B

B B

A C

C

B

B B B B B

AT ABOVE-GRADE MORTAR JOINTS TO BE RAKED OUT AND REPOINTED,

MATCH EXISTING MORTAR COLOR, TEXTURE AND DIMENSIONS, AND

MATCH "GRAPEVINE" PROFILE WHERE APPLICABLE. IN GENERAL,

RECESS FACE OF MORTAR JOINT TO AVOID CONCEALING STONE

ARRISES; REMOVE EXCESS MORTAR FROM FACE OF STONES.

AT ABOVE-GRADE MORTAR JOINTS TO BE RAKED OUT AND REPOINTED,

MATCH EXISTING MORTAR COLOR, TEXTURE AND DIMENSIONS, AND

MATCH EXISTING PROFILE, TYPICAL. IN GENERAL, RECESS FACE OF

MORTAR JOINT TO AVOID CONCEALING STONE ARRISES; REMOVE

EXCESS MORTAR FROM FACE OF STONES.

A-05

PART EAST ELEVATION

BLUESTONE MASONRY REPAIRS

REPAIR MASONRY FOUNDATION AT

THEODORE ROOSEVELT HOUSE

SAGAMORE HILL NATIONAL HISTORIC SITE05/07/20

BLUESTONE WATER TABLE -- JOINTS

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- BED JOINTS

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- JOINTS

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- BED JOINT

NOT TO SCALE

A-05

BLUESTONE WATER TABLE

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- HEAD JOINT

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- BED JOINTS

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- JOINTS

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- HEAD JOINT

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- JOINTS

NOT TO SCALE

A-05

FOUNDATION WALL AT BULKHEAD AREA

NOT TO SCALE

A-05

STONE MASONRY; BLUESTONE WATER TABLE

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- BED JOINTS

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- BED JOINT

NOT TO SCALE

A-05

BLUESTONE WATER TABLE -- HEAD JOINTS

NOT TO SCALE

A-05

DRAWING NO.

PKG

NO. SHEET

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET

A05

A05

A05

A05

A05

A05

A05

A05

A05

A05

A05

A05

A05

A05

A05

OF ___

A05

A05

AT JOINTS BETWEEN

BLUESTONE WATER TABLE

ASHLAR CAP AND FACE

STONES, REMOVE LOOSE,

FRAGMENTED, FRIABLE AND

OTHERWISE FAILED MASONRY

MORTAR. REMOVE ORGANIC

MATTER AND MISCELLANEOUS

DEBRIS. REPOINT JOINTS IN

LIFTS PER THE

SPECIFICATIONS, MATCHING

EXISTING BLUESTONE

MASONRY MORTAR COLOR,

TEXTURE AND JOINT PROFILE,

TYPICAL.

WHERE EXISTING STONE-TO-STONE AND STONE-TO-BRICK MORTAR

JOINTS ARE MISSING OR DISINTEGRATING AT AND/OR JUST BELOW

EXISTING GRADE LEVEL, REMOVE ORGANIC MATTER AND

MISCELLANEOUS DEBRIS. REPOINT IN LIFTS PER THE SPECIFICATIONS.

MATCH EXISTING BLUESTONE MASONRY MORTAR COLOR, TEXTURE

AND JOINT PROFILES, TYPICAL.

NOTE THAT EXISTING BLUESTONE WATER TABLE IS SPALLED AND

DELAMINATED IN SEVERAL AREAS. PROTECT EXISTING STONE FACES

FROM DAMAGE DURING JOINT REPOINTING WORK, TYPICAL.

BRUSH OFF EFFLORESCENCE, AS APPLICABLE. HOWEVER, IF EXISTING

MORTAR JOINTS WERE REPOINTED WITH INAPPROPRIATE MORTARS

AND/OR SEALANTS, RAKE OUT JOINTS, TAKING CARE TO AVOID

DAMAGE TO BLUESTONE. TUCKPOINT JOINTS, MATCHING ADJACENT

BLUESTONE MASONRY MORTAR COLOR, TEXTURE AND JOINT

PROFILES, TYPICAL.

WHERE EXISTING BED JOINTS ARE MISSING OR DISINTEGRATING AT

AND/OR JUST BELOW EXISTING GRADE LEVEL, REMOVE ORGANIC

MATTER AND MISCELLANEOUS DEBRIS. REPOINT IN LIFTS PER THE

SPECIFICATIONS. MATCH EXISTING BLUESTONE MASONRY MORTAR

COLOR, TEXTURE AND JOINT PROFILES, TYPICAL.

WHERE EXISTING STONE-TO-STONE AND STONE-TO-BRICK MORTAR

JOINTS ARE MISSING OR DISINTEGRATING AT AND/OR JUST BELOW

EXISTING GRADE LEVEL, REMOVE ORGANIC MATTER AND

MISCELLANEOUS DEBRIS. REPOINT IN LIFTS PER THE SPECIFICATIONS.

MATCH EXISTING BLUESTONE MASONRY MORTAR COLOR, TEXTURE

AND JOINT PROFILES, TYPICAL.

PHOTO KEY

C

F

B

F

B

B

E

C

F

E F

F

B

B

F

B F

B

E

F

B

B

B

A05

A05

RAKE-OUT INAPPROPRIATE MORTAR/SEALANTS FROM JOINTS, TAKING

CARE TO AVOID DAMAGE TO BLUESTONE. TUCKPOINT JOINTS,

MATCHING ADJACENT INTACT BLUESTONE MASONRY MORTAR, TYP.

IN CONJUNCTION WITH REPOINTING

WORK, TREAT ADJACENT STAINS WITH

CHEMICAL CLEANERS CERTIFIED AS

APPROPRIATE FOR USE ON DRESSED

BLUESTONE, TYPICAL.

A-06

PART NORTH & WEST ELEVATIONS

BLUESTONE MASONRY REPAIRS

REPAIR MASONRY FOUNDATION AT

THEODORE ROOSEVELT HOUSE

SAGAMORE HILL NATIONAL HISTORIC SITE05/07/20

BLUESTONE MASONRY JOINTS

NOT TO SCALE

A-06

BLUESTONE MASONRY JOINTS

NOT TO SCALE

A-06

THEODORE ROOSEVELT HOUSE, NORTHWEST CORNER

NOT TO SCALE

A-06

BLUESTONE MASONRY BED JOINTS

NOT TO SCALE

A-06

BLUESTONE MASONRY BED JOINTS

NOT TO SCALE

A-06

BLUESTONE MASONRY BED JOINTS

NOT TO SCALE

A-06

BLUESTONE WATER TABLE -- JOINTS

NOT TO SCALE

A-06

HEAD JOINTS

NOT TO SCALE

A-06

HEAD JOINTS

NOT TO SCALE

A-06

BLUESTONE WATER TABLE -- JOINTS

NOT TO SCALE

A-06

BLUESTONE MASONRY -- HEAD JOINTS

NOT TO SCALE

A-06

BLUESTONE MASONRY JOINTS

NOT TO SCALE

A-06

DRAWING NO.

PKG

NO. SHEET

OF ___

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET

A06 11 A06

12A06

A06

A06

A06

A06 1 A06

A06

A06

A06

A06

A06

REMOVE LOOSE, FRAGMENTED, FRIABLE AND OTHERWISE FAILED

MASONRY MORTAR. REMOVE ORGANIC MATTER AND MISCELLANEOUS

DEBRIS. REPOINT JOINTS IN LIFTS PER THE SPECIFICATIONS,

MATCHING EXISTING MORTAR COLOR, TEXTURE AND JOINT PROFILE,

TYPICAL.

PHOTO KEY

PHOTO KEY

IN CONJUNCTION WITH

REPOINTING WORK, TREAT

ADJACENT STAINS WITH CHEMICAL

CLEANERS CERTIFIED AS

APPROPRIATE FOR USE ON

DRESSED BLUESTONE, TYPICAL.

B B B

F

F

F

E

E

E

F

F F

E

E

B

EE

E

F

B

F

File details come from the government source that posted it. Updated .