SHEET

DRAWING NO.

PKG. NO.

UNITED STATES

DEPARTMENT OF THE INTERIOR

NATIONAL PARK SERVICE

HACE OF

NAME OF PARK

LOCATION WITHIN PARK

REGION COUNTY STATE

TITLE OF DRAWINGREVISIONMARK SHEET DATE INITA/E FIRM

SAGAMORE HILL NATIONAL HISTORIC SITE

THEODORE ROOSEVELT HOUSE

CONSTRUCTION DOCUMENTS TRH HOME RAILING AND COLUMN RESTORATION AND REHABILITATION

ONE NASSAU NEW YORK

168747

SAHI

251295

SAGAMORE HILL NATIONAL HISTORIC SITE

THEODORE ROOSEVELT HOUSE (TRH)

RAILING AND COLUMN RESTORATION AND REHABILITATION

SAHI 251295

-- COVER SHEET; GENERAL REPAIR/REFINISHING NOTES

A-01 FLOOR PLAN AND PIER/COLUMN KEY; VIEWS;

ARCHITECTURAL MILLWORK TREATMENT KEYS

A-02 REPAIR/REFINISHING OF PIAZZA PIER AND RAILING

ASSEMBLIES

A-03 REPAIR/REFINISHING OF PIAZZA PIER AND RAILING

ASSEMBLIES

A-04 REPAIR/REFINISHING OF FASCIA/SOFFIT, PIAZZA SKIRTING

AND LATTICE PANELS

LIST OF DRAWINGS

NATIONAL PARK SERVICE, HACE/PFCA

INTERIOR REGION 1,

NORTH ATLANTIC - APPALACHIAN

View of TRH piazza from west, 1907

View of TRH piazza from west, 2019

GENERAL WOOD REPAIR / REFINISHING NOTES

1. HISTORIC PRESERVATION TREATMENT: THROUGHOUT THIS PROJECT, INTACT EXISTING

MATERIALS AND SOUND, WELL-ADHERED PAINT FINISHES SHALL BE RETAINED AND

PRESERVED AS MUCH AS POSSIBLE. HISTORIC ELEMENTS THAT ARE EXTENSIVELY

DETERIORATED SHALL BE REPLACED IN KIND, USING SIMILAR WOOD SPECIES AND

MATCHING EXISTING PROFILES AND DIMENSIONS.

2. EXISTING CONDITIONS: THESE DRAWINGS REPRESENT SCHEMATICALLY THE EXISTING

DETAILS AND CONDITIONS OBSERVED DURING THE TIME OF FIELDWORK; CONTRACTOR

SHALL DOCUMENT AND VERIFY ALL CONDITIONS, DIMENSIONS AND PROFILES.

3. EXCLUSIONS:

a. PIAZZA FLOORING, WHEELCHAIR RAMP SURFACE, TREADS AT FRONT STEPS AND

ASSOCIATED COVE MOLDINGS ARE NOT IN CONTRACT (“N.I.C.”).

b. PIAZZA AND PORTE-COCHERE EAVE CORNICES AND GUTTERS, AND ALL SIDING AT

WALLS AND GABLE ENDS, ARE N.I.C.

4. SCOPE OF WORK: UNLESS OTHERWISE NOTED, ALL EXPOSED MILLWORK AT PIAZZA AND

PORTE COCHERE SHALL BE REPAIRED, PATCHED, WASHED, PREPPED AND PAINTED 100%.

COMPONENTS (OR PORTIONS OF COMPONENTS) INDICATED IN BLUE COLOR CODE HEREIN

MAY REQUIRE EXTRA SURFACE PREPARATION WORK INCLUDING, WITHOUT LIMITATION,

REMOVAL OF FAILED PAINT FILMS, CONSOLIDATION OF WEATHERED WOOD AND FILLING

OF HOLES AND MAJOR BLEMISHES.

5. REPLACEMENT IN KIND: BASED UPON DETAILED FIELD MEASUREMENTS OF IN-PLACE AND

SALVAGED COMPONENTS AND, SUBJECT TO GOVERNMENT APPROVAL OF SHOP

DRAWINGS, FABRICATE AND INSTALL REPLICA COMPONENTS AS INDICATED.

6. BACK-PRIMING NEW MILLWORK: BACK-PRIMING HELPS PREVENT PAINT PEELING BY

REDUCING THE AMOUNT OF WATER VAPOR THAT PASSES THROUGH WOOD. PRE-PRIME

OR BACK-PRIME ALL NEW FASCIA AND MOLDING COMPONENTS AND ALL TOP AND BOTTOM

ENDS OF REPLACEMENT BALUSTERS.

7. CUT ENDS: PRIOR TO INSTALLATION OF WOOD DUTCHMAN PATCHES AND COMPONENT

REPLACEMENTS, PRIME THE ENDS OF CUT PIECES, USING APPROVED PRIMER OR

PENETRAING SEALER.

8. JOINERY PREPARATION: AT JOINTS BETWEEN ABUTTING WOOD COMPONENTS (INCLUDING

OPEN MITER JOINTS), RAKE OUT FAILED AND/OR INAPPROPRIATE CAULKING. PROVIDE

NEW PAINTABLE CAULKING BEADS. COORDINATE PAINTING SEQUENCE IN ACCORDANCE

WITH SEALANT MANUFACTURER'S WRITTEN INSTRUCTIONS FOR CURE TIME.

9. CLOSEOUT: REMOVE PAINT DRIPS AND MISCELLANEOUS CONSTRUCTION DEBRIS FROM

WOOD AND MASONRY ELEMENTS AND FROM LANDSCAPE FEATURES.

JG

A-01

FLOOR PLAN AND PIER/COLUMN

KEY; VIEWS; ARCHITECTURAL

MILLWORK TREATMENT KEYS

05/06/20

THEODORE ROOSEVELT HOUSE RAILING AND

COLUMN RESTORATION AND REHABILITATION

SAGAMORE HILL NATIONAL HISTORIC SITE

FLOOR PLAN AND PIER/COLUMN KEY6

A-01

ACCESSIBLE ENTRANCE AREA FROM NORTH-NORTHWEST3

A-01 NOT TO SCALE

SCALE 1/8" = 1'-0" when printed on full-size ANSI D sheet

PIAZZA PIER/BALUSTRADE ASSEMBLIES, OVERALL VIEW FROM SOUTHWEST1

A-01 NOT TO SCALE

PIAZZA PIER/BALUSTRADE ASSEMBLIES, OVERALL VIEW FROM NORTHWEST2

A-01 NOT TO SCALE

PIERS K, J, H and I, FROM NORTH 4

A-01 NOT TO SCALE

PIERS E, F, G, H and I, FROM SOUTHEAST5

A-01 NOT TO SCALE

DRAWING NO.

PKG

NO. SHEET

OF 5

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET

CD

N

J

E

A

B

FGHI

K

L

M

O

P

Q

REPAIR/REFINISHING CATEGORY KEY

IN-KIND COMPONENT REPLACEMENT: DOCUMENT AND

REMOVE INDICATED COMPONENT. PROVIDE REPLACEMENT

THAT MATCHES AND ALIGNS WITH EXISTING

DIMENSIONS/PROFILES. PREP/PRIME/PAINT.

PATCH REPAIR: EXCAVATE, REMOVE AND/OR CUT OFF

DAMAGED AND ROTTED AREAS OF WOOD; PROVIDE NEAT,

SQUARE EDGES. PROVIDE WOOD DUTCHMAN PATCHES OR

EPOXY FILLER AS APPLICABLE. MATCH AND ALIGN WITH

EXISTING DIMENSIONS/PROFILES. PREP/PRIME/PAINT.

CONSOLIDATE / RENEW: HAND-SCRAPE FAILED (e.g., PEELING, FLAKING, FRIABLE) PAINT COATING(S). PRE-PRIME

EXPOSED, WEATHERED WOOD WITH PENETRATING SEALER

AND/OR "STAIN-KILLER" PRIMER. PREP/PRIME/PAINT.

GENERAL PREP AND PAINT: AT PIAZZA AND PORTE-

COCHERE PIER, COLUMN, FASCIA/SOFFIT AND BALUSTRADE

ASSEMBLIES AND PIAZZA SKIRTING AND LATTICE PANELS,

PREP PAINTED/UNPAINTED WOOD SURFACES, NEW AND

EXISTING PATCHES, AND PAINTED FASTENERS.

PRIME/PAINT 100%.

NNNNN

CDBAE

FG

HI

JK

M L N

II

IHJGKLMNO

Q P

O N

IH

JKG

THEODORE ROOSEVELT HOUSE

PIAZZA

PORTE-COCHERE

RAMP

LAWN

DRIVEWAY

ARCHITECTURAL MILLWORK TREATMENT KEY

A. RE-SECURE LOOSE TRIM: USE STAINLESS-STEEL FINISH NAILS;

COUNTERSINK, FILL AND SAND. COORDINATE WITH 100% PRIME/PAINT.

B. PATCH/FILL CRACKS AND OPEN MITER JOINTS: RESET OFFSET

COMPONENTS IF POSSIBLE. IF JOINTS REMAIN, FILL WITH PAINTABLE

SEALANT BEAD; REMOVE EXCESS SEALANT. COORDINATE WITH 100%

PRIME/PAINT.

C. “PLASTIC REPAIR” WITH EPOXY FILLER: CUT OUT AND REMOVE ALL

ROTTED WOOD; USING A SHARP CHISEL, CREATE SQUARE AND NEAT

EDGES. PREPARE SUBSTRATE SURFACES. PATCH WITH EPOXY FILLER,

IN ACCORDANCE WITH FILLER MFR’S WRITTEN INSTRUCTIONS.

COORDINATE WITH 100% PRIME/PAINT.

D. WOOD DUTCHMAN REPAIR: CUT OUT AND REMOVE ALL ROTTED WOOD;

USING A SHARP CHISEL, CREATE SQUARE AND NEAT EDGES.

FABRICATE AND SCREW/GLUE INSTALL DUTCHMAN FOR CLOSE FIT,

ALLOWING NARROW PERIMETER CHANNELS FOR JOINT FILLER. CAULK

JOINTS, SAND AND PRIME. COORDINATE WITH 100% PRIME/PAINT.

E. COMPONENT REPLACEMENT: REMOVE ROTTED COMPONENT AND

DEBRIS. PROVIDE BACK-PRIMED REPLACEMENT COMPONENT TO MATCH

EXISTING PROFILE AND DIMENSIONS; SECURE WITH STAINLESS-STEEL

FINISH NAILS. CAULK JOINTS. COORDINATE WITH 100% PRIME/PAINT.

F. CONSOLIDATE AND FILL WEATHER-CHECKS: USE EPOXY FILLER. AVOID

BRIDGING OVER SOUND WOOD SURFACE. PRE-TREAT UV-DAMAGED

WOOD WITH PROPRIETARY OR CUSTOM-MIXED PENETRATING FINISH;

REFER TO SPECIFICATIONS. COORDINATE WITH 100% PRIME/PAINT.

G. FAILED PAINT: HAND-SCRAPE LOOSE AND FLAKING PAINT. RETAIN AND

PROTECT SOUND AND WELL-ADHERED PAINT (INCLUDING BOTTOM

LAYERS OF GREEN). PRE-TREAT UV-DAMAGED WOOD AS NOTED

ABOVE. COORDINATE WITH 100% PRIME/PAINT.

A

B

C

D

E

F

G

ALLOW FOR

BIDDING PURPOSES:

25 EA. BALUSTERS

4 LF RAILING SOFFIT

16 LF BED MOLDING

8 LF PIER CAP

16 LF PIER BASEBOARD

16 LF PIER BASEBOARD CAP

25 SF WOOD DUTCHMAN

OR EPOXY FILLER PATCHES

2 LF PATCHES AT OPEN

MITER JOINTS

150 SF TOTAL AREA

REQUIRING EXTRA

TREATMENT AND/OR

SURFACE PREPARATION

2,300 SF TOTAL EXT.

MILLWORK SURFACES,

INCL. COLUMNS, FASCIA,

SOFFITS, STAIR RISERS,

SKIRTING, LATTICE PANELS

& PORTE-COCHERE TRELLIS

(FLOOR REFINISHING

IS N.I.C.)

A03

A04

168747

A-02

05/06/20

REPAIR / REFINISHING OF PIAZZA

PIER AND RAILING ASSEMBLIES

THEODORE ROOSEVELT HOUSE RAILING AND

COLUMN RESTORATION AND REHABILITATION

SAGAMORE HILL NATIONAL HISTORIC SITE

PIER P, FROM NORTHEAST

NOT TO SCALE

A-02

PIER Q, FROM NORTHWEST

NOT TO SCALE

A-02

PIER K, FROM NORTHWEST

NOT TO SCALE

A-02

PIER K, FROM SOUTHEAST

NOT TO SCALE

A-02

COLUMN N, FROM NORTHWEST

NOT TO SCALE

A-02

PIER J, FROM SOUTHEAST

NOT TO SCALE

A-02

PIER J, FROM NORTHWEST

NOT TO SCALE

A-02

PORTE-COCHERE PANEL C-D, FROM SE

NOT TO SCALE

A-02

PORTE-COCHERE PANEL C-D, FROM NW

NOT TO SCALE

A-02

COLUMN A, FROM SOUTH

NOT TO SCALE

A-02

RAILING PANEL A-B, FROM SOUTHEAST

NOT TO SCALE

A-02

RAILING PANEL A-B, FROM WEST

NOT TO SCALE

A-02

PIAZZA STAIRWAY, FROM SOUTHWEST

NOT TO SCALE

A-02

PIAZZA STAIRWAY, FROM SOUTHEAST

NOT TO SCALE

A-02

RAILING PANEL A-B, FROM WEST

NOT TO SCALE

A-02

DRAWING NO.

PKG

NO. SHEET

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET

OF 5

E

E

E

E

D

G

C F

DC

G

G

G

D

G

G F

CONSOLIDATE AND PATCH WEATHER-CHECKS, TYPICAL.

C

C

C

G D D

G

E

D

CE

E

REFER TO DETAIL 3 / A-02 FOR TREATMENT NOTES.

C

C C

PREP, PRIME AND PAINT

COLUMN BASES, SHAFTS

AND CAPITALS, TYPICAL

FOR ALL PIAZZA AND

PORTE-COCHERE COLUMNSPREP, PRIME AND PAINT

BALUSTRADE ASSEMBLY,

CAPS AND PORTE-COCHERE

COLUMNS, COMPLETE.

PREP, PRIME AND PAINT

TRELLIS ASSEMBLY,

COMPLETE.

C

PREP, PRIME AND PAINT

COLUMN BASES, SHAFTS

AND CAPITALS, TYPICAL

FOR ALL PIAZZA AND

PORTE-COCHERE COLUMNS

G

PIAZZA

DRIVEWAY

DRIVEWAY

DRIVEWAY

NOTE: REFER TO DRAWING A-01 FOR

ARCHITECTURAL MILLWORK TREATMENT KEY

AND REPAIR/REFINISHING CATEGORY KEY.

PREP, PRIME AND PAINT FRONT

PORCH FASCIA, STILES, RAILS,

AND MOLDED RECESSED PANELS.

PREP, PRIME AND PAINT CURVED STAIR

RISERS, PORCH FASCIA, STILES, RAILS,

STAIR STRINGER AND MOLDED

RECESSED PANELS.

PREP & PAINT PIAZZA

FASCIA (SKIRTING),

TYPICAL.

PREP, PRIME AND

PAINT SOFFIT

ASSEMBLIES. (CEILINGS

AND EAVES ARE N.I.C.)

A-03

REPAIR / REFINISHING OF PIAZZA

PIER AND RAILING ASSEMBLIES

05/06/20

THEODORE ROOSEVELT HOUSE RAILING AND

COLUMN RESTORATION AND REHABILITATION

SAGAMORE HILL NATIONAL HISTORIC SITE

RAILING PANEL M-N, FROM SOUTHEAST

NOT TO SCALE

A-03

RAILING PANEL N-O, FROM NORTHWEST

NOT TO SCALE

A-03

RAILING PANEL H-I, FROM SOUTHWEST

NOT TO SCALE

A-03

RAILING PANEL H-I, FROM NORTHWEST

NOT TO SCALE

A-03

RAILING PANEL F-G, FROM SOUTHWEST

NOT TO SCALE

A-03

RAILING PANEL F-G, FROM NORTHEAST

NOT TO SCALE

A-03

RAILING PANEL L-M, FROM SOUTHWEST

NOT TO SCALE

A-03

RAILING PANEL M-N, FROM NORTHWEST

NOT TO SCALE

A-03

RAILING PANEL G-H, FROM NORTHEAST

NOT TO SCALE

A-03

RAILING PANELS G-H-I, FROM SOUTHWEST

NOT TO SCALE

A-03

RAILING PANEL E-F, FROM SOUTHWEST

NOT TO SCALE

A-03

RAILING PANEL E-F, FROM NORTHEAST

NOT TO SCALE

A-03

RAILING PANEL N-O, FROM SOUTHEAST

NOT TO SCALE

A-03

RAILING PANEL L-M, FROM SOUTHWEST

NOT TO SCALE

A-03

RAILING PANEL G-H, FROM SOUTHWEST

NOT TO SCALE

A-03

RAILING PANEL P-Q, FROM SOUTHEAST

NOT TO SCALE

A-03

RAILING PANEL P-Q, FROM WEST

NOT TO SCALE

A-03

DRAWING NO.

PKG

NO. SHEET

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEETSUB SHEET NO.DESIGNED:DESIGNED:

OF 5

EE

C

E

C

C B

E

CG

E

C

C

G

E E

C

E

G

C E G

E

E

C

E

C G

E

C

REFER TO DETAIL 5 / A-03 THROUGH 9 /A-03 FOR

TREATMENT NOTES.

B

D

C C

E

C

E

CE

E

C

D

PIAZZA FLOORING N.I.C.

LAWN

LAWN

PIAZZA

PIAZZA

PIAZZA

LAWN

LAWN

PIAZZA

RAMP

PIAZZA C

C D

G

NOTE: EXISTING MITERED BED MOLDING IS

SIGNIFICANTLY OFFSET AT THIS JOINT ONLY.

CAULK OPEN JOINTS ONLY; DO NOT RESET.

C

G

E

E

B

A RESECURE.

E

G G

G

E

G

G

F

G

GC GB

C

PROVIDE 14 NEW BALUSTERS, COMPLETE. REFER TO DETAIL

14 / A-02 FOR ADD'L. INFORMATION REGARDING PIER Q.

REFER TO DETAIL 13 /

A-02 FOR ADDITIONAL

INFORMATION

REGARDING PIER P.

REFER TO DETAIL 14 /

A-02 FOR ADDITIONAL

INFORMATION

REGARDING PIER Q.

D

E

G F

G

PROVIDE 6 NEW BALUSTERS, COMPLETE, AT PANEL H-I.

PROVIDE 4 NEW BALUSTERS, COMPLETE, AT PANEL G-H. PROVIDE 1 NEW BALUSTER, COMPLETE, AT PANEL F-G.

G NOTE: REFER TO DRAWING A-01 FOR

ARCHITECTURAL MILLWORK TREATMENT KEY

AND REPAIR/REFINISHING CATEGORY KEY.

REFER TO DRAWING A-4 FOR

REPLACEMENT OF THIS LATTICE

PANEL.

PREP, PRIME AND PAINT PIAZZA FASCIA (SKIRTING)

AND LATTICE PANELS, TYPICAL. PIAZZA FLOORING,

NOSING AND CROWN MOLDING ARE N.I.C.

PREP, PRIME AND PAINT PIAZZA

FASCIA (SKIRTING) AND LATTICE

PANELS, TYPICAL.

PIAZZA

(FLOORING N.I.C.)

PREP, PRIME AND PAINT

PIAZZA FASCIA (SKIRTING)

AND LATTICE PANELS,

TYPICAL.

168747

PREP/PAINT "SKIRTING"

AND RAMP STRINGERS,

TYPICAL.

RAMP SURFACE N.I.C.

PREP/PAINT SKIRT BOARD.

A-04

REPAIR / REFINISHING OF FASCIA /

SOFFITS, PIAZZA SKIRTING, AND

LATTICE PANELS

05/06/20

THEODORE ROOSEVELT HOUSE RAILING AND

COLUMN RESTORATION AND REHABILITATION

SAGAMORE HILL NATIONAL HISTORIC SITE

EXISTING LATTICE PANEL BENEATH M-N

NOT TO SCALE

A-04

PROPOSED NEW LATTICE PANEL BENEATH M-N

NOT TO SCALE

A-04

SKIRTING (FASCIA) AND LATTICE PANEL BENEATH G-H

NOT TO SCALE

A-04

EXISTING LATTICE PANEL BENEATH M-N

NOT TO SCALE

A-04

PROPOSED NEW LATTICE PANEL BENEATH M-N

NOT TO SCALE

A-04

TYPICAL SKIRTING (FASCIA) AND LATTICE PANEL

NOT TO SCALE

A-04

PORTE-COCHERE FASCIA AND SOFFITS , FROM SOUTHEAST

NOT TO SCALE

A-04

PORTE-COCHERE FASCIA AND SOFFITS , FROM SOUTHWEST

NOT TO SCALE

A-04

PIAZZA FASCIA AND SOFFIT, FROM SOUTHWEST

NOT TO SCALE

A-04

PIAZZA SOFFIT ASSEMBLY, FROM SOUTH

NOT TO SCALE

A-04

PIAZZA FASCIA AND SOFFIT, FROM NORTHWEST

NOT TO SCALE

A-04

PORTE-COCHERE DETAIL

NOT TO SCALE

A-04

DRAWING NO.

PKG

NO. SHEET

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEETSUB SHEET NO.DESIGNED:DESIGNED:

OF 5

NOTE: REFER TO DRAWING A-01 FOR

ARCHITECTURAL MILLWORK TREATMENT KEY

AND REPAIR/REFINISHING CATEGORY KEY.

REMOVE EXISTING TRIANAGULAR

WOOD LATTICE PANEL ASSEMBLY.

PRIME AND PAINT (FLAT BLACK)

EXPOSED PORTION OF CMU STEM

WALL WITH PAINT SYSTEM SUITABLE

FOR CONCRETE MASONRY. RETAIN

ELECTRICAL RECEPTACLE.

NOTE EXPOSED CONCRETE BLOCK (CMU) STEM WALL AND

UTILITY DUPLEX ELECTRICAL RECEPTACLE.

PROVIDE NEW PRIMED AND PAINTED RECTANGULAR LATTICE

PANELM SECURED TO PIAZZA FRAMING. CENTER LATTICE

PATTERN IN FLAT FRAME; MATCH ADJACENT LATTICE

DIMENSIONS AND SPACING. INCORPORATE AND SCRIBE-IN

UTILITY DUPLEX ELECTRICAL RECEPTACLE TO REMAIN.

MAKE MINOR ADJUSTMENTS TO GRADE IMMEDIATELY

ADJACENT TO PANEL, AS REQUIRED. REMOVE

MISCELLANEOUS SOIL AND DEBRIS.

F

PROTECT SECURITY SYSTEM

CAMERAS AND ASSOCIATED

HARDWARE, TYPICAL.

PIAZZA CEILING N.I.C.

PORTE-COCHERE

CEILING N.I.C.

G

PROTECT HISTORIC, FIXED

AND OPERABLE METAL

HARDWARE, TYPICAL. G

FILL WEATHER CHECKS AND PRE-TREAT WEATHERED WOOD, AS INDICATED

OR REQUIRED. PREP, PRIME AND PAINT 100%.

AT PORTE-COCHERE FASCIA AND SOFFIT COMPONENTS, FILL WEATHER CHECKS

AND PRE-TREAT WEATHERED WOOD AS INDICATED OR REQUIRED. PREP, PRIME

AND PAINT 100%.

EAVE CORNICES,

GUTTERS AND

OVERHANGING SOFFIT

ARE N.I.C.

PREP, PRIME AND PAINT

PORTE-COCHERE FASCIA

AND SOFFIT

COMPONENTS, 100%.

PREP, PRIME AND PAINT

SKIRTING (FASCIA) AND ALL

LATTICE PANELS, 100%.

PIAZZA FLOORING,

NOSING AND

ASSOC. COVE

MOLDING ARE N.I.C.

PREP, PRIME AND

PAINT FASCIA AND

SOFFIT COMPONENTS.

EAVE CORNICES AND

GUTTERS ARE N.I.C.

File details come from the government source that posted it. Updated .