A06_Appendix_A-Fog_Signal_Pages_from_Asbestos_and_Lead_Based_Paint_Assessment_Survey_2023.pdf
PDF 3 MB Posted
- Attached to
- WI-HORICON NWR-SIGNAL BUILDING PROJECT
- Solicitation number
- 140FC225Q0051
About this file
This document is an asbestos and lead-based paint inspection report for the US Fish and Wildlife Service Fog Signal building on Plum Island, Wisconsin. On May 17, 2023, TriMedia Environmental & Engineering conducted a comprehensive hazardous materials survey of the approximately 1,000 square foot two-story brick building. The asbestos survey identified several materials containing asbestos, including brown and red floor tiles (3-9% Chrysotile), transite siding (10% Chrysotile), and white caulk (4% Chrysotile) surrounding windows and doors. Additionally, the lead inspection using X-ray fluorescence (XRF) detected lead-containing paint on multiple exterior and interior components, including trim, soffits, door frames, and sign posts.
The report recommends managing asbestos-containing materials according to OSHA and EPA regulations, and notes that all paint on the building is in damaged condition with significant peeling and chipping. TriMedia suggests repairing lead-containing painted surfaces through enclosure, encapsulation, or abatement before the building is accessible to the public. The inspection also identified potential health hazards such as animal feces and mold, recommending proper clean-up protocols and addressing water infiltration. The building's poor condition and the presence of hazardous materials necessitate careful remediation before any future use or public access.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
830 W. Washington Street Marquette, MI 49855
906.228.5125
906.228.5126 Fax
www.trimediaee.com
US Fish and Wildlife – Plum Island, WI Fog Signal
TriMedia was on-site on May 17, 2023 to conduct sampling to identify the presence of asbestos-containing materials (ACM), lead-containing paint and other hazardous materials within the identified building. The property was in poor condition; however, safe entry was possible to all desired areas.
The site is approximately 1,000 sq. ft. two-story property. The property is constructed of brick with wood framing and metal supports. The shingled roof appears to be less than 10 years of age;
however, remnants of the former roof remain. The assessment is intended to identify building contaminants that, if mismanaged during demolition or alteration activities, could pose an environmental or health and safety concern.
ASBESTOS SURVEY
TriMedia collected a total of 25 samples (consisting of 37 sample layers) of suspect asbestos-containing materials to be submitted for laboratory analysis. Sample Locations for Asbestos can be found in Figure 1: Asbestos Sample Locations.
ASBESTOS RESULTS
Asbestos was detected in the following materials;
• Samples 001a through 001c brown floor tile and mastic are between 3% and 8% Chrysotile and is found within the watch room.
• Samples 002a through 002c red floor tile and mastic range from 5% and 9% Chrysotile and is found within the watch room.
• Samples 005a through 005c transite siding are 10% Chrysotile and is found surrounding the watch room.
• Samples 008a through 008c white caulk are 4% Chrysotile and is found surrounding all exterior windows and doors.
The shingled roof and other roofing materials were not sampled as part of the assessment and should be treated as presumed asbestos containing materials and must be sampled prior to replacement or disturbance.
Complete analytical laboratory results have been enclosed for your records. Sampled materials, locations, and analytical results have been summarized in Table 1: Materials Sampled and Found to Not Contain Asbestos and Table 2: Materials Sampled and Found to Contain Asbestos.
LEAD INSPECTION
▪ TriMedia utilized an XRF to perform a lead inspection collecting 26 unique readings of different building components as required per EPA/HUD inspection protocols. The inspection was limited to the exterior of the building and one interior reading to confirm it being of high lead content. Sample Locations for Lead can be found in Figure 2: Lead Sample Locations.
Inspection Report
LEAD CONTAINING PAINT RESULTS
XRF readings detected the presence of lead equal to or above EPA/HUD regulation of 1 mg/cm2 in 18 readings. A full summary of building component readings and estimated quantities can be found in Table 3: Lead Inspection
OTHER HAZARDOUS MATERIALS
Animal feces can be a serious indoor air quality concern based on the presence of fungus and yeast capable of infecting humans through inhalation and can also contain Escherichia Coli SP. (E. Coli).
While there are no current regulatory guidelines for feces disposal or remediation, it is recommended that personnel receive training on proper clean up methods, personal protection, and potential health hazards prior to clean up.
The building has the potential for elevated levels of mold. It is important to note that all individuals respond differently to their environments, and some individuals may be sensitive to airborne mold spores even at lower spore counts. There is no regulatory limit for disposal or established threshold levels at which adverse health effects are documented. TriMedia recommends stopping water infiltration into the building and cleaning the building with a bleach based cleaner to remediate any historical mold growth.
SUMMARY OF FINDINGS AND RECOMMENDATIONS
▪ Asbestos containing material must be managed in accordance with provisions stipulated in States Occupational Safety and Health Administration (US OSHA) Safety and Health Regulations for Construction, Part 29 Code of Federal Regulations 1926.1101 and in accordance with applicable provisions in Environmental Protection Agency (EPA) National Emissions Standards for Hazardous Air Pollutants (NESHAP) 40 CFR Part 61, Subpart M.
▪ It is TriMedia’s opinion that all paint on the Fog Signal building is in damaged or significantly damaged condition with peeling and chipping occurring on all lead containing paints. The window and components, door and components, soffit and fascia, sign and signposts, sump pit doors, and all interior surfaces should be treated as lead containing paint. It is TriMedia’s opinion that lead-containing painted surfaces be repaired by enclosure, encapsulation, or abatement prior to the building being open to the general public. In addition, TriMedia recommends that items currently stored within the building be covered to prevent chipping paint from falling on them.
▪ Information regarding painted surfaces must be provided to contractors who may be performing paint-disturbing activities and to scrap metal dealers or other entities who may take possession of the materials. Applicable state, federal and local regulations for worker and environmental protection must be met when impacting lead-containing paint during paint-disturbing activities. Additional requirements may be enforced based on owning agency policies and procedures, up to Housing and Urban Development (HUD) requirements.
TriMedia made every reasonable attempt to access all areas of the building. However, as with all hazardous material assessments, there exists the potential for discovering additional suspect materials not addressed by this report during demolition activities. In the event suspect materials are identified during on-site activities, they must be sampled before being disturbed.
Inspection Report
Enclosures: Table 1: Materials Sampled and Found to Not Contain Asbestos Table 2: Materials Sampled and Found to Contain Asbestos Table 3: Lead Inspection Figure 1: Asbestos Sample Locations Figure 2: Lead Sample Locations Photo Log Asbestos Photo Log Lead EMSL Analytical Reports
Sincerely, TriMedia Environmental & Engineering Services, LLC
Tim Sorensen, ASP Project Industrial Hygienist State of Wisconsin Inspector AII-188677 Lead Inspector License LRA-188677
Table 1 Materials Sampled and Found to Not Contain Asbestos
USFWS
Fog Signal - Plum Island TriMedia 2023-0280
Sample # (Layers)* Material/Description
FS-A-003a Watch room Walls below 4 ft Drywall
FS-A-003b Watch room Walls below 4 ft Drywall
FS-A-003c Watch room Walls below 4 ft Drywall
FS-A-004a Watch room Walls above 4 ft Cellulose Acoustical tile
FS-A-004b Watch room Walls above 4 ft Cellulose Acoustical tile
FS-A-004c Watch room Walls above 4 ft Cellulose Acoustical tile
FS-A-005a (1 of 2) Surrounding whole building On exterior walls tar paper (exterior)
FS-A-005b (1 of 2) Surrounding whole building On exterior walls tar paper (exterior)
FS-A-005c (1 of 2) Surrounding whole building On exterior walls tar paper (exterior)
FS-A-006a (2) Watch room Perimeter of floor Cove base molding and adhesive
FS-A-006b (2) Watch room Perimeter of floor Cove base molding and adhesive
FS-A-006c (2) Watch room Perimeter of floor Cove base molding and adhesive/glue
FS-A-007a Cupola On ground within attic Cellulose blown in pile
FS-A-007b Cupola On ground within attic Cellulose blown in pile
FS-A-007c Cupola On ground within attic Cellulose blown in pile
FS-A-009 Exterior West Taken from ground pile Shingles
*Material layers separated in lab
Location Details
Table 2 Materials Sampled and Found to Contain Asbestos
USFWS
Fog Signal - Plum Island TriMedia 2023-0280
Sample # (Layers)* Material/Description Material Condition Asbestos Concentration Estimated
Quantity**
Estimated Abatement
Cost**
FS-A-001a (1 of 2) Brown Floor Tile Significantly Damaged 8% Chrysotile
FS-A-001a (2 of 2) Brown Floor Tile Mastic Significantly Damaged 3% Chrysotile
FS-A-001b (1 of 2) Brown Floor Tile Significantly Damaged Stop Positive
FS-A-001b (2 of 2) Brown Floor Tile Mastic Significantly Damaged Stop Positive
FS-A-001c (1 of 2) Brown Floor Tile Significantly Damaged Stop Positive
FS-A-001c (2 of 2) Brown Floor Tile Mastic Significantly Damaged Stop Positive
FS-A-002a (1 of 2) Red Floor tile Significantly Damaged 9% Chrysotile
FS-A-002a (2 of 2) Red Floor tile Mastic Significantly Damaged 5% Chrysotile
FS-A-002b (1 of 2) Red Floor tile Significantly Damaged Stop Positive
FS-A-002b (2 of 2) Red Floor tile Mastic Significantly Damaged Stop Positive
FS-A-002c (1 of 2) Red Floor tile Significantly Damaged Stop Positive
FS-A-002c (2 of 2) Red Floor tile Mastic Significantly Damaged Stop Positive
FS-A-005a (1 of 2) Surrounding whole building On exterior walls Transite Siding (exterior) Damaged 10% Chrysotile
FS-A-005b (1 of 2) Surrounding whole building On exterior walls Transite Siding (exterior) Damaged Stop Positive
FS-A-005c (1 of 2) Surrounding whole building On exterior walls Transite Siding (exterior) Damaged Stop Positive
FS-A-008a All exterior walls door/window borders Caulk (exterior) Significantly Damaged 4% Chrysotile
FS-A-008b All exterior walls door/window borders Caulk (exterior) Significantly Damaged Stop Positive
FS-A-008c All exterior walls door/window borders Caulk (exterior) Significantly Damaged Stop Positive
Material Condition
Good = No damage at all
Damaged = evenly distributed damage over <10% of a functional space/material or localized over <25% of a functional space/material
Significantly Damaged = evenly distributed damage over 10% or more of the functional space/material or localized over 25% of a functional space/material
*Material layers separated in laboratory
$900 to $6,675
Watch room Floor
$825 to $2,451
$82.50 to $245
$700 to $2,352
**The provided quantities and estimated costs are for engineering and budgeting purposes only and should not be used for contractor bid development. Bidding contractors should produce internal quantifications based on their work plan.
Location Details
150 sqft
15 sq ft
147 sq ft
150 ln ft
Watch room Floor
Watch room Floor
Watch room Floor
Watch room Floor
Watch room Floor
Table 3 - Lead Inspection USFWS - Plum Island
Fog Signal TriMedia 2023-0280
Sample
ID #
Sample Side
Room Equivalent Component Substrate Color XRF Reading HUD/EPA
Classification Lead
Containing Material
Condition Estimated Quantity** Estimated Abatement Cost**
FS-Pb-1 A Exterior Wall Brick White 0.005 Negative Yes Damaged NA NA
FS-Pb-2 A Exterior Wall Brick Gray 0.032 Negative Yes Damaged NA NA
FS-Pb-3 A Exterior Trim Wood Gray 3.409 Positive Yes Damaged 31.25 sq ft $781.25 - $937.50 FS-Pb-4 A Exterior Soffit Metal Gray 3.634 Positive Yes Damaged 125 sq ft $3125 - $3750 FS-Pb-5 A Exterior Trim Wood Red 0.134 Negative Yes Damaged NA NA
FS-Pb-6 A Exterior Door Trim Wood White 2.147 Positive Yes Damaged 8 sq ft $200 - $240 FS-Pb-7 A Exterior Door Header Wood White 2.992 Positive Yes Damaged 4 sq ft $100 - $120 FS-Pb-8 B Exterior Wall Brick White 0.273 Negative Yes Damaged NA NA
FS-Pb-9 B Exterior Wall Brick Gray 0.032 Negative Yes Damaged NA NA
FS-Pb-10 B Exterior Window Sill Wood White/Gray 3.164 Positive Yes Damaged 8 sq ft $200 - $240 FS-Pb-11 B Exterior Window Header Wood White 1.441 Positive Yes Damaged 4 sq ft $100 - $120 FS-Pb-12 B Exterior Door Trim Wood White 4.333 Positive Yes Damaged 8 sq ft $200 - $240 FS-Pb-13 B Exterior Door Header Wood White 3.942 Positive Yes Damaged 4 sq ft $100 - $120 FS-Pb-14 B Exterior Trim Wood White 3.802 Positive Yes Damaged 31.25 sq ft $781.25 - $937.50 FS-Pb-15 B Exterior Wall Transite White 0.011 Negative Yes Damaged NA NA
FS-Pb-16 B Exterior Window Trim Wood White 2.023 Positive Yes Damaged 4 sq ft $100 - $120 FS-Pb-17 B Exterior Soffit Wood White 2.243 Positive Yes Damaged 125 sq ft $3125 - $3750 FS-Pb-18 B Exterior Fascia Wood White 3.929 Positive Yes Damaged 62.5 sq ft $1562.5 - $1875 Fs-Pb-19 B Exterior Wall Trim Wood White 3.005 Positive Yes Damaged 31.25 sq ft $781.25 - $937.50 FS-Pb-20 B Exterior Sump Door Metal Yellow 1.61 Positive Yes Damaged 18 sq ft $450 - $540 FS-Pb-21 C Exterior Foundation Concrete Gray 0.021 Negative Yes Damaged NA NA
FS-Pb-22 D Exterior Sign Posts Metal Gray 1.846 Positive Yes Damaged 230 sq ft $5750 - $6900 FS-Pb-23 D Interior Walls Brick White 9.125 Positive Yes Damaged NA (all interior) NA
FS-Pb-24 D Interior Door Jamb Wood White 2.363 Positive Yes Damaged 80 sq ft $2000 - $2400 FS-Pb-25 D Exterior Door Wood Green 2.363 Positive Yes Damaged Included with Jamb Included with Jamb
FS-Pb-26 D Exterior Door Floor Concrete Yellow 0.063 Negative Yes Damaged NA NA
Material Condition Good = No damage at all Damaged = evenly distributed damage over <10% of a functional space/material or localized over <25% of a functional space/material Significantly Damaged = evenly distributed damage over 10% or more of the functional space/material or localized over 25% of a functional space/material
Table 3 - Lead Inspection USFWS - Plum Island
Fog Signal TriMedia 2023-0280
Calibration Check
Fog Signal
Test Type Device XRF Serial No. Contractor Inspector NIST SRM Used
Calibration Check Tolerance Used First Reading Second
Reading Third Reading Average
Initial SciAps X- 550 00342 TriMedia TRS 1.04 0.8-1.2 1.105 1.057 1.051 1.071
20 Sample SciAps X- 550 00342 TriMedia TRS 1.04 0.8-1.2 1.11 1.072 1.066 1.082666667
Post
SciAps X-
550 00342 TriMedia TRS
1.04 0.8-1.2 1.13 1.07 1.041 1.080333333
**The provided quantities and cost estimates are for engineering and budgeting purposes only and should not be used for contractor bid development. Bidding contractors should produce internal quantifications based on their work plan.
US FISH & WILDLIFE – PLUM ISLAND
FOG SIGNAL - ASBESTOS
Photo Log Page 1 of 6 Fog Signal - Asbestos TriMedia Project #2023-0280
Description: FS-A-001a – brown floor tile – 8% Chrysotile Date: 5/17/23 Taken By: AJV
Description: FS-A-001b – brown floor tile – 8% Chrysotile
Description: FS-A-001c – brown floor tile – 3%-8% Chrysotile Date: 5/17/23 Taken By: AJV
Description: FS-A-002a – red floor tile – 5%-9% Chrysotile
Photo Log Page 2 of 6
Description: FS-A-002b – red floor tile – 5%-9% Chrysotile
Description: FS-A-002c – red floor tile – 5%-9% Chrysotile
Description: FS-A-003a - drywall
Description: FS-A-003b - drywall
Photo Log Page 3 of 6
Description: FS-A-003c - drywall
Description: FS-A-004a – cellulose acoustical tile
Description: FS-A-004b – cellulose acoustical tile
Description: FS-A-004c – cellulose acoustical tile
Photo Log Page 4 of 6
Description: FS-A-005a – transite siding – 10% Chrysotile
Description: FS-A-005b – transite siding – 10% Chrysotile
Description: FS-A-005c – transite siding – 10% Chrysotile
Description: FS-A-006a – cove base
Photo Log Page 5 of 6
Description: FS-A-006b – cove base
Description: FS-A-006c – cove base
Description: FS-A-007abc - Cellulose
Description: FS-A-008a – Caulk – 4% Chrysotile
Photo Log Page 6 of 6
Description: FS-A-008b – Caulk – 4% Chrysotile
Description: FS-A-008c – Caulk – 4% Chrysotile
Description: FS-A-009 - shingles
FOG SIGNAL - PAINT
Photo Log Page 1 of 5 Fog Signal - Paint
Description: FS-Pb-3 – gray trim – 3.409
Description: FS-Pb-4 – gray soffit – 3.634
Description: FS-Pb-6 – white door trim – 2.147
Description: FS-Pb-7 – white door header – 2.992
Photo Log Page 2 of 5
Description: FS-Pb-10 – white/gray windowsill – 3.164
Description: FS-Pb-11 – white window header – 1.441
Description: FS-Pb-12 – white door trim – 4.333
Description: FS-Pb-13 – white door header – 3.942
Photo Log Page 3 of 5
Description: FS-Pb-14 – white trim – 3.802
Description: FS-Pb-16 – white window trim – 2.023
Description: FS-Pb-17 – white wood soffit – 2.243
Description: FS-Pb-18 – white wood fascia – 3.929
Photo Log Page 4 of 5
Description: FS-Pb-19 – white wall trim – 3.005
Description: FS-Pb-20 – yellow sump door – 1.610
Description: FS-Pb-22 – gray sign posts – 1.846
Description: FS-Pb-23 – white interior wall – 9.125
Photo Log Page 5 of 5
Description: FS-Pb-24 – white door jamb – 2.363
Description: FS-Pb-25 – green door – 2.363
EMSL Analytical, Inc.
15111 Northville Rd Plymouth, MI 48170
Tel/Fax: (734) 668-6810 / (734) 668-8532 http://www.EMSL.com / annarborlab@emsl.com
082301060EMSL Order:
Customer ID: TRIC50
Customer PO: 2023-0280
Project ID:
Attention: Phone:Tim Sorensen (906) 228-5125
Fax:TriMedia Environmental & Engineering Svs (906) 228-5126
Received Date:830 W. Washington St 05/23/2023 12:45 PM
Analysis Date:Marquette, MI 49855 05/24/2023 - 05/25/2023
Collected Date:
Project: 2023-0280-Plum Island Fog Signal
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
FS-A-001a
082301060-0001
8% ChrysotileNon-fibrous (Other)92%Tan
Non-Fibrous
Heterogeneous
Floor Tile
FS-A-001a
082301060-0001A
3% ChrysotileNon-fibrous (Other)97%Black
Non-Fibrous
Heterogeneous
Mastic
FS-A-001b
082301060-0002
Positive Stop (Not Analyzed)Floor Tile
FS-A-001b
082301060-0002A
Positive Stop (Not Analyzed)Mastic
FS-A-001c
082301060-0003
Positive Stop (Not Analyzed)Floor Tile
FS-A-001c
082301060-0003A
Positive Stop (Not Analyzed)Mastic
FS-A-002a
082301060-0004
9% ChrysotileNon-fibrous (Other)91%Red
Non-Fibrous
Heterogeneous
Floor Tile
FS-A-002a
082301060-0004A
5% ChrysotileNon-fibrous (Other)95%Black
Non-Fibrous
Heterogeneous
Mastic
FS-A-002b
082301060-0005
Positive Stop (Not Analyzed)Floor Tile
FS-A-002b
082301060-0005A
Positive Stop (Not Analyzed)Mastic
FS-A-002c
082301060-0006
Positive Stop (Not Analyzed)Floor Tile
FS-A-002c
082301060-0006A
Positive Stop (Not Analyzed)Mastic
FS-A-003a
082301060-0007
None DetectedNon-fibrous (Other)80%Cellulose20%White
Fibrous
Heterogeneous
Drywall
FS-A-003b
082301060-0008
None DetectedNon-fibrous (Other)85%Cellulose15%White
Fibrous
Heterogeneous
Drywall
FS-A-003c
082301060-0009
None DetectedNon-fibrous (Other)93%Cellulose7%Brown/Gray
Fibrous
Heterogeneous
Drywall
FS-A-004a
082301060-0010
None DetectedNon-fibrous (Other)10%Cellulose90%Tan
Fibrous
Homogeneous
Ceiling Tile
Initial report from: 05/30/2023 16:33:25
Page 1 of 3ASB_PLM_0008_0001 - 1.78 Printed: 5/30/2023 4:33 PM
Tel/Fax: (734) 668-6810 / (734) 668-8532 http://www.EMSL.com / annarborlab@emsl.com
082301060EMSL Order:
Customer ID: TRIC50
Customer PO: 2023-0280
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
FS-A-004b
082301060-0011
None DetectedNon-fibrous (Other)10%Cellulose90%Tan
Fibrous
Homogeneous
Ceiling Tile
FS-A-004c
082301060-0012
None DetectedNon-fibrous (Other)5%Cellulose95%Brown/White
Fibrous
Heterogeneous
Ceiling Tile
FS-A-005a
082301060-0013
10% ChrysotileNon-fibrous (Other)90%Gray
Fibrous
Heterogeneous
Transite
FS-A-005a
082301060-0013A
None DetectedNon-fibrous (Other)10%Cellulose90%Black
Fibrous
Heterogeneous
Tar Paper
FS-A-005b
082301060-0014
Positive Stop (Not Analyzed)Transite
FS-A-005b
082301060-0014A
None DetectedNon-fibrous (Other)10%Cellulose90%Black
Fibrous
Heterogeneous
Tar Paper
FS-A-005c
082301060-0015
Positive Stop (Not Analyzed)Transite
FS-A-005c
082301060-0015A
None DetectedNon-fibrous (Other)20%Cellulose80%Black
Fibrous
Homogeneous
Tar Paper
FS-A-006a
082301060-0016
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Cove Base
FS-A-006a
082301060-0016A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Adhesive
FS-A-006b
082301060-0017
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Cove Base
FS-A-006b
082301060-0017A
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Adhesive
FS-A-006c
082301060-0018
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Cove Base
FS-A-006c
082301060-0018A
None DetectedNon-fibrous (Other)100%Cellulose<1%Brown/Yellow
Non-Fibrous
Heterogeneous
Adhesive/Glue
Inseperable Layers
FS-A-007a
082301060-0019
None DetectedNon-fibrous (Other)6%Min. Wool94%White
Fibrous
Homogeneous
Insulation
FS-A-007b
082301060-0020
None DetectedNon-fibrous (Other)4%Min. Wool96%White
Fibrous
Homogeneous
Insulation
FS-A-007c
082301060-0021
None DetectedNon-fibrous (Other)2%Cellulose
Min. Wool
8%
90%
Gray
Fibrous
Homogeneous
Insulation
FS-A-008a
082301060-0022
4% ChrysotileNon-fibrous (Other)96%Gray
Non-Fibrous
Heterogeneous
Caulk
FS-A-008b
082301060-0023
Positive Stop (Not Analyzed)Caulk
Page 2 of 3ASB_PLM_0008_0001 - 1.78 Printed: 5/30/2023 4:33 PM
Tel/Fax: (734) 668-6810 / (734) 668-8532 http://www.EMSL.com / annarborlab@emsl.com
082301060EMSL Order:
Customer ID: TRIC50
Customer PO: 2023-0280
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
FS-A-008c
082301060-0024
Positive Stop (Not Analyzed)Caulk
FS-A-009
082301060-0025
None DetectedQuartz
Non-fibrous (Other)
8%
37%
Cellulose55%Black
Fibrous
Heterogeneous
Shingles
Analyst(s)
Eric Budai (6)
Kassandra Maraz (19)
Eric Budai, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Plymouth, MI NVLAP Lab Code 101048-4
Page 3 of 3ASB_PLM_0008_0001 - 1.78 Printed: 5/30/2023 4:33 PM
OrderID: 082301060