A06 0040469875 20190607 Drawings.pdf
PDF 31 MB Posted
- Attached to
- MECHANICAL SYSTEM UPGRADES FOR CHARLESTOWN NAVY YA Federal contract opportunity
- Solicitation number
- 140P4320R0004
About this file
This pre-solicitation notice announces an upcoming solicitation for mechanical system upgrades at two buildings of the Charlestown Navy Yard in Boston, Massachusetts. The Department of the Interior National Park Service Northeast Region seeks to remove and replace air handling units and boilers at one building, and replace an air handling unit and modify ductwork at a museum lobby in another building. The total small business set-aside contract has a base requirement and two options, with an estimated price range of $500,000 to $1,000,000. The period of performance is 180 calendar days beginning no earlier than November 1, 2020. Interested parties should monitor the website for the full solicitation expected to be issued on or around July 31, 2020.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| R002 Temp Parking Application .pdf | ||
| B03 140P4320R0004 20200313 Wage Determination MA20200001 Mod 3.pdf | ||
| A06 0040469875 20190607 Project Specifications.pdf | ||
| Attachment 0004 Limitations on Subcontracting Report.xlsx | XLSX spreadsheet | |
| Sol_140P4320R0004.pdf | ||
| B08 140P4320R0004 Attach R001 PPQ.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE OF FEET
500 0 500 I I I I I I
I I I I I
150 0 150
SCALE OF METERS
BOSTON NATIONAL HISTORICAL
Mark Sheet REVISION Date Initial QUALITY DESIGN CERTIFICATION
D Prepared in Accordance with Design Development (Title 1) ____ _ OR Drawing No.
D Variance from Design Development (Title 1) Approved by Superintendent on~~- OR Dote
D Construction Drawing Not Preceded by Design Development (Title 1)
Project Manager Date
SCALE OF FEET
LEGEND
v.c.
HQ.
HISTORICAL PARK BOUNDARY
VISITOR CENTER
PARK HEADQUARTERS
AMBRIDGE
ESSEX
CHARLESTOWN ,
NAVY YARD. - -
TO DORCHESTER
HEIGH7EJ I
MASSACHUSEI IS
1 ,000 0 1 ,000
SCALE OF FEET
CHARLESTOWN NAVY YARD
BOSTON NATIONAL HISTORICAL PARK
BUILDINGS 22 & 28
BOSTON,MASSACHUSETTS
MECHANICAL SYSTEM UPGRADES FOR
CHARLESTOWN NAVY YARD BLDGS.22 & 28
USS CONSTITUTION MUSEUM
C'\I C'\I
KEY PLAN
CONNECTOR
CX)
C'\I
INDEX
SUB
SHEET SHEET TITLE OF SHEET
COVERSHEET
DEMO PLAN BLDG 22
DEMO PLAN BLDG 28
DEMO PLAN CONNECTOR
SCHEDULES AND NOTES
AHU-9 REPLACEMENT PLAN
BLDG 28 AHLI REPLACEMENT
CONNECTOR AHLI COMPONENT REPLACEMENT
BOILER PIPING DETAILS
MECHANICAL DETAILS
I , , , , I I I I
I 16'X32' SPACE FOR
DUMPSTER UNDER
CRANE
cs
DM1
DM2
DM3
MO
M1 M2 M3 M4 M5 M6 M7
EO
E1 E2 E3
CONTROL DIAGRAMS
CONTROL DIAGRAMS
ELECTRICAL ONE-LINE DIAGRAM
150 0 150
SCALE OF METERS
PARKING FOR
THREE VEHICLES
PARK
CONSTRUCTION DRAWINGS
UNITED STATES
DEPARTMENT OF THE INTERIOR
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
DOOR ACCESS AND
WINDOW ACCESS TO
MECHANICAL ROOM
A/E FIRM:
PRIME:
!CDS, LLC
GUILFORD, CT
SUBCONTRACTOR:
DESIGNED:
SDF
KFH
TECH. REVIEW:
DSF
DATE:
06/07/2019
SUB SHEET NO.
cs
AHU-9 REPLACEMENT ELEC PART PLAN
AHU-28 REPLACEMENT ELEC PART PLAN
OMITTED
TITLE OF DRAWING
MECHANICAL SYSTEM UPGRADES FOR
CHARLESTON NAVY YARD BLDGS. 22 &: 28
LOCATION WITHIN PARK
BUILDINGS 22 & 28
NAME OF PARK
BOSTON NATIONAL HISTORICAL PARK
REGION
NORTHEAST
COUNTY
SUFFOLK
STATE
MASSACHUSETTS
DRAWING NO.
144216
PMIS/PKG NO.
BOST 232490
SHEET
rl ,-
I'\ .,, I ,., I I .,, I 1,:'.'.'.__~J
_J
STAIRS
I
J
LOBBY
-- I
PANEL "LAP"
B 1 PANEL "LAL"
I I II\ r, ,,..., J / I ,,, I I ,.., I 1,:'.'.'.__~J
I -~--+-r--t -'~_.... -~ -_ ----t-1--~..-D-IS_C_ON-N;CT / / , - ,
- SUPPL y DIFFUSER LI I
- 1 ............. ) .. ,, ... ....-- AND RELOCATE (SE,c : I
I _.............. INSTALL PLANS) I I
I I
36x32 RETURN--.. ""- GRILLE "-r-. I -
>-----------< I
I STd:>RAGE ROOM
PROJECTION
BOOTH
I I
-f---
\ I I
I ~ STORAGE /
~OPTION A
I
7..,.__ rl ___________ ~
STORAGE ROOM
st c..
x~ ROOM c:!i Cl)
1 ~---++--+DUCT DETECT~ R SH/4LL BE
I / REMOVED & RELOCATED
I ,-------+-,l~~ R_::_H,;,_;-9c-1:::::::::tr-1 DEMO SUPPLY TO Jl---~~,~~I-r-.... -1 REHEAT COIL. COIL
;:r ~ "·'r.',:j AND ALL PIPING TO 2 -z ,:,:·,<~~;::, REMAIN. MECH
ROOM
24x14
RETURI
.:,'-.4.,,.;L.C, ~--++---+-EXISITNG AHU-9 AND
SUPPORT STAND TO
BE REMOVED.
I
I
I RETURN HEADER TO REMAIN. DEMO I
L ALL CONDENSER AND RETUR~ I
- - -- - - -- - - D_u_cT_s_c~~C_T_ED_T_O !-~-~
'1' BUILDING 22 1st FLOOR MECHANICAL PLAN ~ 4 0 4 8 -- ----
SCALE IN FEET
[:::I C!)
_J
CONNECTOR
AUDITORIUM
KEY PLAN
I I -----------------------------------------------~ I DEMOLITION SCOPE OF WORK
11. AIR HANDLER AHU-9 SHALL BE REMOVED. EXISTING SUPPLY AND RETURN AS SHOWN
I SHALL REMAIN FOR RECONNECTION TO NEW AIR HANDLER.
OPTION A--~ 2. DISCONNECT AND REMOVE EXISTING ELECTRICAL DISCONECT SWITCH. RETURN TO
OWNER FOR FUTURE USE. REMOVE EXISTING CONDUCTORS AND CONDUIT BACK TO
PANEL PP1.
C!)
_J
3. DEMO PLANS (BACKGROUNDS, EQUIPMENT LAYOUTS, DUCTS, ETC.) REFLECT AS-BUILT
DOCUMENTS WHICH ARE DEPICTED HERE. REFER TO INSTALLATION PLANS FOR ANY
FIELD VERIFIED DIFFERENCES FROM AS-BUILT DRAWINGS.
4. ALL EXISTING LIGHTING AND RECEPTACLES SHALL REMAIN. CONTRACTOR SHALL
REMOVE AND REINSTALL AS REQUIRED TO ACCOMODATE NEW DUCTWORK AND
MECHANICAL EQUIPMENT INSTALLATION. REFER TO ELECTRICAL PLAN FOR FIXTURE TYPE
AND QUANTITY.
5. ALL EXISTING DUCT DETECTORS SHALL BE REMOVED AND REINSTALLED. COORDINATE
WITH ELECTRICAL DRAWINGS.
I I
WOMEN MEN
jHATC~ L __ J
FIRST FLOOR SUBSTATION
MECHANICAL ROOM
BELOW AHU-2
H'
I
A/E FIRM:
PRIME:
ICDS, LLC
GUILFORD, CT
SUBCONTRACTOR:
DESIGNED: SUB SHEET NO.
SDF
KFH
TECH. REVIEW:
DSF DM1
DATE:
06/07/2019
I
TITLE OF DRAWING
DEMO PLAN BLDG. 22
LOCATION WITHIN PARK
BUILDINGS 22 & 28
NAME OF PARK
BOSTON NATIONAL HISTORICAL PARK
REGION
NORTHEAST
COUNTY
SUFFOLK
STATE
MASSACHUSETTS
DRAWING NO.
144216
PMIS/PKG NO.
BOST 232490
"" I I x.! I
SPRINKLER VALVE
ROOM
C\I C')
11 )( )(1 1
'St C\I C')
DEMO EXISTING
BOILER PAD TO SLAB
-$- UTILITY SINK
TO REMAIN
11x11
DUCTDETECTORSHALLBE --tt=:l:::::::::::t-~777~~'7JS<
REMOVED & RELOCATED
MECHANICA
ROOM
MATCHLINE
REMOVE 18x18 COMBUSTION
AIRDU~
-- - -------0
DISCONNNECT ALL DUCTS AND
PATCH EXISTING OA PLENUM
10"0 BOILER FLUE DEMO'D TO
BOTTOM OF VERTICAL RISE AND
CAPPED. ENSURE ENOUGH DROP
BELOW CEILING FOR CONNECTION
OF COMB AIR INTAKES (SEE M2)
SUPPLY AND RETURN DUCTS
SHALL REMOVED TO JUST INSIDE
CEILING AND/OR WALL
PENETRATIONS, TYPICAL.
l----~,;;;;:--/l---~=::::!,--------c!. __ J,---L__Ll===='--1-- - ---@
ALL EXISTING MECHANICAL EQUPMENT,
ASSOCIATED DUCTWORK, PIPING,
STRUCTURAL SUPPORTS, BOILER PAD,
ELECTRICAL AND CONTROL EQUIPMENT SHALL
BE REMOVED EXCEPT AS NOTED.
'1'\ BUILDING 28 1st FLOOR MECHANICAL PLAN \...}_} 4 0 4 8 -- ----
SCALE IN FEET
DEMOLITION SCOPE OF WORK
1. ALL EQUIPMENT IN THE BLDG 28 MER SHALL BE REMOVED, EXCEPT
AS NOTED. EXISTING SUPPLY, RETURN AND OUTSIDE AIR PLENUM AS
WELL AS CHILLED WATER LINES AND GAS LINES SHALL REMAIN AT
ROOM WALL PENETRATION FOR RECONNECTION TO NEW AIR HANDLER.
2. DISCONNECT REMOVE ALL HOT WATER AND CONDENSATE PIPING.
3. DISCONNECT AND REMOVE EXISTING ELECTRICAL DISCONECT SWITCH.
RETURN TO OWNER FOR FUTURE USE. REMOVE EXISTING CONDUCTORS
AND CONDUIT BACK TO PANEL LIA.
4. DEMO PLANS (BACKGROUNDS, EQUIPMENT LAYOUTS, DUCTS, ETC.)
REFLECT AS-BUILT DOCUMENTS WHICH ARE DEPICTED HERE. REFER
TO INSTALLATION PLANS FOR ANY FIELD VERIFIED DIFFERENCES FROM
AS-BUILT DRAWINGS.
5. ALL EXISTING LIGHTING AND RECEPTACLES SHALL REMAIN.
CONTRACTOR SHALL REMOVE AND REINSTALL AS REQUIRED TO
ACCOMODATE NEW DUCTWORK AND MECHANICAL EQUIPMENT
INSTALLATION. REFER TO ELECTRICAL PLAN FOR FIXTURE TYPE AND
QUANTITY.
6. ALL EXISTING DUCT DETECTORS SHALL BE REMOVED AND
RELOCATED. COORDINATE WITH ELECTRICAL DRAWINGS.
KEY PLAN
A/E FIRM:
PRIME:
ICDS, LLC
GUILFORD, CT
SUBCONTRACTOR:
DESIGNED:
SDF
KFH
TECH. REVIEW:
DSF
DATE:
06/07/2019
SUB SHEET NO.
DM2
TITLE OF DRAWING
DEMO PLAN BLDG. 28
LOCATION WITHIN PARK
BUILDINGS 22 & 28
NAME OF PARK
BOSTON NATIONAL HISTORICAL PARK
REGION
NORTHEAST
COUNTY
SUFFOLK
STATE
MASSACHUSETTS
DRAWING NO.
144216
PMIS/PKG NO.
BOST 232490
" ~ m ..
m
'" rl rl
OPTION B -KEEP EXISTING AHU-2
AND REPLACE ONLY
THE COMPONENTS
BELOW
I ,...., I
REMOVE HW COIL
REMOVE CHW COIL
,.._ I ,.---., I ~EMOVE MIXING
- ~ ----- SECTION AND
OADUCT
,-- --- I--
L I r
II
t=-=t===t=,=====',C1i '.___----li ~ \ I I / 1 - I ./ ¥----l p-11 ! 1 1 ! :rYJ / I V
H
1-------< r HATCH f-t-+-c::-:-:---7¼-~-~{ SUBSTATION
I
I I
\ I \ I \ I \I
' I\ I I
I \ I I
~6x14 ~.
~ETURN L~J J MECHANICAL LOFT
t-t----t-t--------a==l==,==="'.,i:!, I I
1 BOILER BELOW
I I I
I I I
I I
! I I 3Q ~--------------------------------------------------~-------~--~----------
F1
'1' SUBSTATION MECHANICAL LOFT
~ 4 a 4 8 -- ----
SCALE IN FEET
A/E FIRM: DESIGNED:
PRIME: SDF
CONNECTOR ~(······· .•• ICDS, LLC ~-•·• (!) CX) GUILFORD, CT Cl <N
KFH ...J (!)
"' Cl
...J •• . 00187811 TECH. REVIEW: "' .. .. SUBCONTRACTOR: DSF
DATE: KEY PLAN 06/07/2019
SUB SHEET NO. TITLE OF DRAWING DRAWING NO.
DEMO PLAN CONNECTOR 457
LOCATION WITHIN PARK 144216
DM3 BUILDINGS 22 & 28 PMIS/PKG NO •
BOST 232490 NAME OF PARK
BOSTON NATIONAL HISTORICAL PARK SHEET
REGION COUNTY STATE 4 OF 16 NORTHEAST SUFFOLK MASSACHUSETTS
AIR HANDLING UNITS
IDENTIFICATION AHU DATA SUPPLY FAN MOTOR MOTOR CONTROL HOT WATER COIL CHILLED WATER COIL
TAG NO. SERVICE LOCATION MFR MODEL NO. FAN TYPE AIR FLOW (CFM) TSP /ESP RPM HPOR RPM VOLTS 0 TYPE CONTROL STATUS EAT LAT HTG APD EWT LWT GPM WPD ROWS FPF CAP. EDB EWB CLG LDB LWB APD EWT LWT GPM WPD ROWS FPF SMBH TMBH (IWG) FLA ('F) ('F) CFM (IWG) ('F) ('F) (FT) (MBH) ('F) ('F) CFM ('F) ('F) (IWG) ('F) ('F) (FT)
AHU-3 BLDG 28 BLDG28MER TRANE CSAA022UA
PLENUM DIRECT
8690 4.75 / 2.0 1800 42.0 FLA 1800 208 3 VFD SPEED RUNNING NO HOT WATER COIL SECTION 71.9 63.6 8690 50.0 49.9 1.065 45 55.2 72.8 8.86 10 150 209.6 337.3
DRIVE
11-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
OP~~NA ! SELF CONTAINED AIR CONDITIONING UNIT
I IDENTIFICATION MFR/ MODEL EVAPORATOR FILTER COMPRESSOR CONDENSER ELECTRICAL
I TAG NO. SERVICE LOCATION MFR MODEL SIZE SUPPLY BLOWER BLOWER MOTOR COIL COIL FACE COIL FPI TYPE QTY DIM. EFF TYPE QTY AIR BLOWER BLOWER MOTOR COIL COIL COIL CHARGE R-410A VOLTAGE PHASE HZ REPLACE I
Lb~u~ AIR SIZE QTY (HP@ 1.0" ESP) ROWS AREA (CFM) SIZE QTY (HP) ROWS FACE AREA FPI (LB-OZ) (PER CIRCUIT)
EXIS=N~ AHU-91
MUSEUM ENTRY LOBBY BLDG 22 MECH RM UNITED COOLAIR VERICOOL 8TON 3200 CFM 10 -8 1 1 1/2 4 9 12 PLEATED THROWAWAY 1 / 2 16x25x2 / 20x25x2 MERV8 SCROLL 2 6000 15 -9 2 3 4 11.25 12 25-6 208 / 230 3 60
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --re-- -- -- -- -- -- -- -- -- -- -- --n FILTER SECTIONS CHILLED WATER COILS IDENTIFICATION AIRFLOW PREFILTERS HIGH EFFICIENCY FILTERS MID-LIFE ~p I
I IDENTIFICATION CHILLED WATER COILS
I TAG NO. SERVICE CFM PREFIL TER TYPE PREFILTER EFF. TYPE SIZE MFR MODEL VEL (FPM) EFF. HOUSING MFR HOUSING MODEL PRE (IWG) HEF (IWG)
I TAG NO. SERVICE LOCATION EDB ('F) EWB ('F) LDB ('F) LWB ('F) CFM APD (IWG) EWT ('F) LWT ('F) GPM WPD (FT) ROWS FPI SIZE (H X W) SMBH TMBH AHU-3 AHU-3 SEEAHU 2" CARTRIDGE MERV8 CARTRIDGE BYAHU MFR AIRGUARD LEGACY <500 MERV 15 AIRGUARD SIDE ACCESS 12" 0.60 0.89
I FU-2 AHU-2 4780 2" CARTRIDGE MERV8 CARTRIDGE 60"X24" (05X02) AIRGUARD LEGACY < 500 MERV 15 AIRGUARD SIDE ACCESS 12" 0.60 0.89 AHU-2 SUBSTATION ATTIC 70.6 61.0 49.0 48.9 4,780 1.104 45.0 55.0 31.64 11.44 8 14 27X 51 113.4 158.7
-- -- -- -- -- -- -- -- -- - - ~Tl ON B FILT~R~EPLACEMiN,I IN EXISTl!iG~HU-2 I
HOT WATER COILS I
HOT WATER BOILERS
IDENTIFICATION MFR/ MODEL PERFORMANCE DATA HYDRONIC DATA COMBI ELECTRICAL
IDENTIFICATION HOT WATER COILS
I TAG NO. SERVICE LOCATION EAT ('F) LAT ('F) CFM APD (IWG) EWT ('F) LWT ('F) GPM WPD (FT) ROWS FPI SIZE (H XW) CAP. (MBH) TAG NO. SERVICE MFR MODEL FUEL INPUT (MBH) OUTPUT (MBH) MODULATION AFUE / Eth MAXEFF. % GPM EWT ('F) LWT ('F) !'.P (FT) DHW (GPM) VOLTAGE PHASE MCA I HTCL-1 CONNECTOR AHU-2 SUBSTATION ATTIC 49.0 77.8 4,780 0.135 140 120.0 14.98 0.67 2 6 27X51 149.5 I WB-1 HOT WATER LOCHINVAR WHN400 NG 399 377 20% TO 100% 94.4% 99% 38 110 130 1.4 N/A 115 1 15
[ __ WB-2 HOT WATER/DHW LOCHINVAR NKC110N NG 110 102 10% TO 100% 95.0% 99% 10.1* 160 180 6.0 2.6 115 1 15 OPTION B I NOTES: C~L ~EPLACEM,:N2, IN EXISTl~G ~HU-2 I * PRIMARY PUMP FOR BOILER WB-2 IS PROVIDED IN BOILER -- -- -- -- -- -- --
HVAC SCOPE OF WORK
PUMPS
THIS PROJECT INCLUDES THE MAINTENANCE REPLACEMENT OF AGING AIR HANDLING UNITS AND
IDENTIFICATION PUMP MOTOR MOTOR CONTROL OTHER EQUIPMENT.
TAG NO. SERVICE LOCATION TYPE MFR MODEL NO. GPM HEAD (FT) BHP RPM HP RPM VOLTAGE 0 TYPE CONTROL STATUS
BASE BID
P-AHU-3 AHU-3 REHEAT COILS BLDG28 MER ECM WET ROTOR BELL & GOSSETT
ECOCIRCXL
38 40 0.855 2481 2 2481 208 3 ECM 0-10 VFD FAULT
95-160
THE MAJOR EQUIPMENT/COMPONENTS AFFECTED ARE:
P-B1 BOILER WB-1 BLDG28 MER ECM WET ROTOR BELL & GOSSETT
ECOCIRCXL
38 25 0.49 1983 2 1983 208 3 ECM 0-10 VFD FAULT • AHU-3: CHILLED WATER AIR HANDLING UNIT SERVING THE 2ND FLOOR OF BLDG. 28 (EXHIBIT SPACE)
95-160 • AHU-4: CHILLED WATER AIR HANDLING UNIT SERVING THE 1ST FLOOR OF BLDG. 28 (EXHIBIT SPACE)
P-RAD CUH-1 AND BASEBOARD BLDG 28 MER ECM WET ROTOR BELL & GOSSETT
ECOCIRCXL
10 20 0.143 2872 0.5 2872 208 1 ECM 0-10 VFD FAULT • THE BUILDING 28 BOILER SHALL BE REPLACED WITH A NEW GAS-FIRED CONDENSING BOILER (WB-1)
55-45
IMPROVEMENTS ARE AS FOLLOWS:
PROJECT INSTALLATION BASIS
1. AHU-3 AND AHU-4 SHALL BE REMOVED AND BE CONSOLIDATED INTO ONE NEW (AHU-3) AIR HANDLING
REHEAT COILS UNIT WITH TWO ZONES TWO RE-HEAT COILS.
IDENTIFICATION HOT WATER COILS
2. A SEPARATE SMALL HYDRONIC/DOMESTIC COMBI BOILER (WB-2) IN THE BUILDING 28 MECHANICAL
STANDARDS: ROOMS IS PROVIDED TO SUPPORT THE HIGH TEMP BASEBOARD AND CABINET UNIT HEATER LOADS TAG NO. SERVICE LOCATION EAT ('F) LAT ('F) CFM APD (IWG) EWT ('F) LWT ('F) GPM WPD (FT) ROWS FPI SIZE (H XW) CAP. (MBH) IN THE BUILDING AS WELL AS THE UTILITY SINK. NOTE: THIS WILL ENABLE THE MUCH LARGER RH-3-1 2ND FLOOR BLDG 28 MER 50.0 91.1 5,200 .28 130 110 23.4 15.5 2 16 23.8x46 132.6 SMACNA DUCT CONSTRUCTION STANDARDS: METAL & FLEXIBLE HEATING BOILER (WB-1) TO MAXIMIZE CONDENSING OPERATION RH-3-2 1ST FLOOR BLDG 28 MER 50.0 85.0 3,490 .20 130 110 13.4 13.9 2 12 20x40 132.2
ASME B31.9 "BUILDING SERVICES PIPING" 3. CONNECTIONS FOR A FUTURE SOLAR THERMAL SYSTEM (UNDER A SEPERATE CONTRACT) IS
INTEGRATED INTO THE BUILDING HOT WATER SYSTEM
4. NEW CONTROLS SHALL BE PROVIDED FOR THE REPLACED AIR HANDLING UNITS USING HONEYWELL
CODES: TRIDIUM OR OTHER APPROVED NIAGARA N4 SYSTEM
5. CONTRACTOR SHALL PATCH ALL DRYWALL PENETRATIONS PER SPECIFICATION SECTION107329 AND
• 780 CMR COMMONWEALTH OF MASSACHUSETTS STATE PAINT TO MATCH EXISTING.
BUILDING CODE
• MASSACHUSETTS STATE ELECTRICAL CODE (527 CMR 12.00) OPTION A
• THE 2015 INTERNATIONAL MECHANICAL CODE (IMC)
• 2017 NATIONAL ELECTRIC CODE • AHU-9: SELF-CONTAINED AIR CONDITIONING UNIT SERVING THE MUSEUM ENTRY LOBBY
IMPROVEMENTS ARE AS FOLLOWS:
1. AHU-9'S DUCTWORK IS EXPANDED TO ADD ADDITIONAL AIRFLOW FOR THE REPLACEMENT UNIT, INCLUDING RELOCATION OF A DIFFUSER FROM THE STORAGE CLOSET
2. PROVIDE AND INSTALL NEW INTAKE LOUVERS FOR AHU-9.
OPTION B
• AHU-2: CHILLED WATER AIR HANDLING UNIT SERVING THE CONNECTOR BUILDING (EXHIBIT SPACE)
IMPROVEMENTS ARE AS FOLLOWS:
1. IN LIEU OF REPLACING AHU-2, THE CHW AND HW COILS IN THE EXISTING MCC SHALL BE REPLACED
WITH NEW COILS AS LISTED ON THIS SHEET. IN ADDITION THE EXISTING MCC MIXING BOX SHALL BE DISCONNECTED AND REPLACED WITH A TWO STAGE FILTER UNIT AIRGUARD MODEL SA (21" DEPTH)
WITH 2" PREFIL TER AND 12" CARTRIDGE FILTER (SEE SCHEDULE ABOVE).
A/E FIRM: DESIGNED: SUB SHEET NO. TITLE OF DRAWING DRAWING NO.
<c. o~}?.Q~~~c~ PRIME: SDF SCHEDULES & NOTES 457 ~-P-~-~ ICDS, LLC 144216 ~-•·• LOCATION WITHIN PARK o.,: "•'-' GUILFORD, CT {Ii i* KFH
MO BUILDINGS 22 & 28 PMIS/PKG NO.
,~~8780 ---~ TECH. REVIEW: NAME OF PARK BOST 232490 ·--~--- SUBCONTRACTOR: \ ~-........ • DSF BOSTON NATIONAL HISTORICAL PARK SHEET
- DATE: REGION COUNTY C, STATE
5 OF 16 ./ '-7"·.r---- 06/07/2019 NORTHEAST SUFFOLK MASSACHUSETTS
I I I
CONNECTOR
-1 --1---- ----------------~1
1, "- I __________ B ,-,--- _ I ._- -,, I I ._- ---,,
- - - - - - 7 - -:-?I
I
STAIRS I
I x:,J 24x6 I I I x:,J
I RE-BALANCE EXISTING
DIFFUSERS TO 600 CFM
I EACH (TYP FOR 4)
I SEIHO PK SPOT DIFFUSER, 5" DIAM
ANODIZED BLACK
100 CFM (TYP FOR 6)
24x10 I .,/" I ------ ~ - I
I I
RELOCATED DIFFUSER, PATCH
BACK DRYWALL AS REQ'D FOR
INSTALLATION. MATCH EXISTING
PAINT dOLO~.
I----~~ --l
- -i---~~--------------r ------ri I -- I x 4x6 I I 24x10 I I I
·'""-b"'.~---------------L-L_ -----~ I
-----7
I 36x32 RETURN
GRILLE
STORAGE ROOM
GENERAL NOTE:
PROVIDE FIRE STOPPING AT ALL
THROUGH PENETRATIONS IN RATED
WALL, CEILING AND FLOOR ASSEMBLIES
TO MAINTAIN THE LISTED ASSEMBLY IN
ACCORDANCE WITH APPLICABLE CODE
REQUIREMENTS
I I I I
FURNISH SHEET METAL TO SEAL OFF
OLD DIFFUSER TAKE OFF AND PROVIDE
COLLAR TO RUN NEW 12" FLE.'""'X~D~U~CT~~-~~
TO RELPCAT~D DIFFUSE LO ATION
SHOWN1. I
STORAGE ROOM
MECH
ROOM
(E)RH-9-1
I
PROJECTION
BOOTH
AREA DENOTES
MAIN ACCESS
STORAGE ROOM
I A FURNISH NEW OA I
.. I ___ - --- - --- - - --- - - --- - - ---- - LOUV:.R_ - - ___ I
0 BUILDING 22 1st FLOOR MECHANICAL PART PLAN 4 0 4 8 -- ----
SCALE IN FEET
[:::I C!)
_J
CD
KEY PLAN
C!)
_J
CD
2'-6"
AHU-9
[OPTIONA _
--- OA TO CONNECT TO 38X41
INTAKE BELOW (NOT SHOWN)
405 CFM
_.--- (E) RETURN DUCT
32x41 DISCHARGE
PROVIDE 80x50 LOUVER TO MATCH EXISTING
WINDOW OPENING. CONTRACTOR SHALL
VERIFY DIMENSIONS IN THE FIELD.
GREEN HECK MODEL: EDD-401 OR APPROVED
EQUAL. REMOVE OLD TRIM & CONDUIT.
RECESS LOUVER IN MASONRY OPENING TO I
ALIGN WITH EXISTING WOOD TRIM AND SEAL
PERIMITER STONE-ALUM JOINT. PROVIDE I
2-COAT KYNAR FINISH IN MFR'S STD COLOR
AS APPROVED BY CONTRACTING OFFICER TO
BLEND WITH SURROUNDING GRANITE
FACADE. ROUTE NEW 3/4" EVAP
CONDENSATE LINE THROUGH NEW LOUVER.
L----+t-- , -- PROVIDE NEW BOLTED
CONNECTION STAND SIZED TO FIT
BIGGER UNIT RATED TO 1200 LBS
(APPROX 3' HIGH)
FIELD WELDING IS NOT PERMITTED.
'2' SECTION A-A
\..V2 0 2 4 -- ----
A/E FIRM:
PRIME:
ICDS, LLC
GUILFORD, CT
SUBCONTRACTOR:
SCALE IN FEET
DESIGNED: SUB SHEET NO.
SDF
KFH
TECH. REVIEW:
DSF M1
DATE:
06/07/2019
TITLE OF DRAWING
AHU-9 REPLACEMENT PLAN
LOCATION WITHIN PARK
BUILDINGS 22 & 28
NAME OF PARK
BOSTON NATIONAL HISTORICAL PARK
REGION
NORTHEAST
COUNTY
SUFFOLK
STATE
MASSACHUSETTS
DRAWING NO.
144216
PMIS/PKG NO.
BOST 232490
"U I s:: s:: 9 r 0 rn )> :::c gJ rn en z 0 :;E I < ;o ~ C 0 ...... <G) I s:: rn 0 u, oo rn en 0 I .-:IN en ""Tl "U ""Tl r - ;o - ~
I ~ en z rn r ' rn en
I )> ' -I rn 0 rn r -n rn rn -I 0 ""Tl - ;o 0 0 I
-I
I r ~ en -I 0 --1 rn rn 0 z z rn ;o o z L_J
;o -I z
AHU-3 SECTION DETAILS
10'-~"
~-7- ,-1 - --7 I I I
I I I I I I I Cl I 10 01 __,,,.
I I I I _J I .............._ I I - -
• L,_ - _J dk\fl;I . - ( . .. . •· .• ....• : ,( ..... · .. ·. . . ·. · . .. ' . . ~ .. · · .• ·• 4, ... ,I
AHU-3 ELEVATION
0 AHU-3 SECTION DETAILS & ELEVATION
\.V 2 0 2 4 -- ----
SCALE IN FEET
I GENERAL NOTE:
PROVIDE FIRE STOPPING AT ALL THROUGH
PENETRATIONS IN RATED WALL, CEILING AND FLOOR
ASSEMBLIES TO MAINTAIN THE LISTED ASSEMBLY IN
ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS
I I
I ~ I
~ INTO EXISTING AHU-4 ,,,. - LOCATION OF CONTROLS
~---I-/--'-~"'=--'-~T,,,_UR'--"N--'!..!:!JAl"-"R'-'-P-=LE""N_,_,U,..,,M'-'------------------=-nv I .r HYDRO SEPARATOR -------
/rRH-3-2 c _ ~c _ _J
40X20 HW COIL
24X20 / I r,;;, I'--,_ I __,/ L ' ---- 'V t-+-~~---,, I -......._" )-V I I ·· I /, I I I ,........ I / I .,,.... ,...... ~ I /
- ..l_ - --=,- - - - - - - - - - - - -4o1c12 r-..... ;;(...... --... t:t:,I ,1=//====I KDi=I O I . V'- -'-I-...., I-''---, - ~1ax180UTSIDEAIR f-,_-.v ~-----~ /' l--° DUCT(2200CFM)
_/ / P- -3 , '-(} ' CONNECT HIGH AS POSSIBLE TO ---~.v EXISTING INTAKE PLENUM/ LOUVER
~ PB-1 _L_2" NAT. GAS : ~----'I ,...
V ~-' LINE l----+- -1--------~~i-~.- V ti'E INTO EXISTING GAS RISER TIE INTO SUPPLYAIRATWALL -~ ... _... ..._ ... _ ... _ ,9 - -,.-= I....,._ '"'" -- , ... , -_/ --,....- ... ----..... -- ______ ,.. _____ --!-------- ..... t- - ------ v v t-LOCK-UP GAS REGULATOR
NOTE: SEE M4 FOR "9'' I . .....__4"0 BOILER l e I I kl (10' AHEAD OF BOILERS MINIMUM)
WB-1 SYSTEM PIPING WB-1 COMB AIR ___ I_ _ _ _ LJ I V
PIPING DETAILS • I~,.. 0 I _ ,...,..,~ 1-T-----' ..,v,-EXISTING 10"0 BOILER FLUE USED ~ I 4"0BOILER t---+- t------- _ :o:t- J v "'" ASASLEEVEFORNEWCPVCFLUES
WB-1 TO SERVE RH-3-1 AND__/' ·, LFLUE / I !--IA.I - ,~::::i ~ AND INTAKES RH-3-2 (SEE PIPING DETAIL) ~ - ---- _______ , .l( -- --1--------·'" I ---~ • 38x14 RETURN UNDER SUPPLY
_r3"0 BOILER -I- 3 I / / COMB AIR 1% , 1 "•" a j I DUCT AND ABOVE AHU- ~-- r--------------·~ ~- ·- ~ ----v wB-2 r3"0 BOILER L ~ 1 1 - 1 11
CONNECT EXISTING HIGH TEMP_/ G--- _____ L_..£LUE ___ ,.._ __ ,,.. ~ ,.._ ____ ,,.., '" ....... ~1+---- 1--------~10
RADIANT CIRCUIT (RISING UP ~ I _ '' I I
INTO CEILING) TO WB-2 PIPING ,t--t--, ·111 P-RAD - : - : I -TIE INTO EXISTING AHU-3
RETURN (38x14) AT CEILING (SEEPIPINGDETAILONM4) ,.. ~ MECHANICAL. l.: -~ :j
LOCATE SYSTEM PUMP----- □ ROOM
P-RAD AS NECESSARY □ ____ 40x12 a: 1 ----ft-1rr-EXISTING 2" NAT. GAS LINE
PERDETAILONM4 , ,.._-t-~- -~-+-~ 11 _.1,,1111 ~"7'..7'7'7'. I
· · · · • • • • • • _ -TIE INTO EXISTING AHU-3
I ~ V SUPPLY(40x18)ATCEILING
AHU-3
MOUNTED ON 6" HOUSEKEEPING PAD
(NOTE: THIS IS A CONSOLIDATION OF
AHU-3 & AHU-4 TO ONE AHU)
I ; --- --~ _/ _,...,...><._.___ ✓- RH-3-1
40x12 SUPPLY UP AND ......_ ._ , ,_ 1 ~-- v 46x23.75 HW COIL IN
OVE~/ TOP OF AHU-3 ~L ___ J:=:::;~'==~H RISER
32x30 SUPPLY '- _......- ~ / -TIE INTO EXISTING AHU-3 PLENUM ~ ~ '-......._ k,: ..,V SUPPLY(40x18)ATCEILING
~ ~ /ci,/·~-
I I
I I --._..J..EXISTING 3" CHWS/R
I
/ L...,,<-~, ~1
.-------r' PIPING INTO MER FROM
~~Cl~~•o.LV..Lw~r.R•~A,n=--~-----1-----------~j,11 ,..__ _______ '-~.--,------.,.- /-+-r-'1.._____,_I--Jl..__ ___ _.1
N N Cl ..J Cl]
CHW PIPING ENTRANCE INTO BUILDIN~ l l
ROUTE AND CONNECT TO NEW AHU-3
USING 2-1/2" PROVIDE SHUT-OFF VALVES
AND LOW POINT DRAINS AT ENTRANCE
(SEE COIL PIPING DETAIL ON M5)
M
0 ~UILDING 28 1st FLOOR MECHANICAL PLAN 2 0 2 4 -- ----
SCALE IN FEET
A/E FIRM: DESIGNED: SUB SHEET NO. TITLE OF DRAWING
PRIME: SDF BLDG 28 AHU REPLACEMENT ..
.. ICDS, LLC .. ~-•·• LOCATION WITHIN PARK "' GUILFORD, CT N KFH M2 BUILDINGS 22 & 28 (!)
Cl ..J ••• 00187811 TECH. REVIEW: NAME OF PARK ID .. .. SUBCONTRACTOR: DSF BOSTON NATIONAL HISTORICAL PARK
KEY PLAN DATE: REGION COUNTY STATE
06/07/2019 NORTHEAST SUFFOLK MASSACHUSETTS
DRAWING NO.
144216
PMIS/PKG NO.
BOST 232490
" ~ " rl rl
I - (E) 140 _ (E) 140
I (E) 180
RECONNECT TO EXISTING OA DUCT '"""--..__
(E) 220 SUPPLY
EXISITNG ACCESS HATCH
TO THE ATTIC MER FROM
THE BOILER ROOM BELOW
L I r
1--
.J I l~ ---rl---1<:~-:,l '» X
H
VAV-
,6x!.1,- ~ -- ~ URN l~ J
' I v----,......0::::-~- -
----r--.. - ---
SUBSTATION
MECH LOFT
I
\ I \I I\
I \
I I I
I I
I ~ (E) 32x20 RETURN TOP VV (E) 48x20 SUPPLY BOT
~----------------------------------------------~·------~·~---~·----------.----t30
F1
~ SUBSTATION MECHANICAL LOFT
~ 4 0 4 8 -- ----
SCALE IN FEET
A/E FIRM: DESIGNED: SUB SHEET NO.
PRIME: SDF
CONNECTOR ~(······· .•• ICDS, LLC ~-•·• (!) CX) GUILFORD, CT Cl <N
KFH M3 ...J (!)
"' Cl
...J •• . 00187811 TECH. REVIEW: "' .. .. SUBCONTRACTOR: DSF
DATE: KEY PLAN 06/07/2019
TITLE OF DRAWING DRAWING NO.
CONNECTOR AHU COMPONENT REPLACEMENT 457
144216 LOCATION WITHIN PARK
BUILDINGS 22 & 28 PMIS/PKG NO •
BOST 232490 NAME OF PARK
REGION COUNTY STATE 8 OF 16 NORTHEAST SUFFOLK MASSACHUSETTS
LEGEND*
(D CHECKVALVE
@ BUTTERFLYVALVE
@ THERMOWELL FOR CONTROL SENSOR
@ ISOLATION BALL VALVE
@ HYDRO SEPARATOR (CALEFFI 548, 2" FLG)
@ STRAINER
(D HOT WATER BUFFER/ HYDRAULIC SEPARATOR (40 GAL)
@ LOW WATER CUT-OFF (MAY BE PROVIDED W/ BOILER)
@ SAFETY RELIEF VALVE (ASME 30 PSI)
@ BOILER DRAIN VALVE
@ TEMPERATURE & PRESSURE GUAGE
@ UNION
@ UNION & PVC TEE ASSEMBLY (FACTORY SUPPLIED)
@ NEUTRALIZER KIT
@ 40 GALLON BUFFER TANK
@ 20 GALLON INDIRECT WATER HEATER (SSU-20)
@ BALANCE VALVE
@ PUMP FOR IT-1 (8 GPM)
*NOT ALL ITEMS USED
PRESSURE
RELIEF VALVE ----1
(REQUIRED.
FIELD SUPPLIED)
TEMPERATURE /
PRESSURE GUAGE I
HOT
WATER I
SUPPLY
EXPANSION
TANK
1/
COLD
I WATER
I SUPPLY
DOMESTIC HOT WATER
CONN@BLR
©© 2"
1" TAPS FOR FUTURE SOLAR HOT
WATER SYSTEM
@0 @@ L2" "!lt----10H-4@-io1~17~1----.
@ P-B1
~_..,........_~01-----,...f-,fC-------'---.--''---------,----------\ HW RETURN FROM REHEAT COILS
LCLOSELY
SPACED TEES
12" MAX
2" HW PIPE BRANCH SIZES
B-1
399 MBH
MER DRAIN
2"
EXPANSION TANK TO BE SIZED BY
CONTRACTOR BASED ON FINAL
PIPING VOLUME. DESIGN BASED ON
AMTROL AX-20V
DIFF PRESS XMITR
@© G>©
'-------:::1-10~01-------'------.. HW SUPPLY TO REHEAT COILS
P-AHU-3
BYPASS/FILL
UNIT
RH-3-1
RH-3-2
FLOW
24GPM
13 GPM
1/2" @ @ @ @ @ 1/2"
"B" .,_---1----io'~o----~1r1 .-'}-t,,1--101-1 ---1--_.,.,,gg~~~~~ER
J , BACK-FLOW
MAIN BOILER (WB-1) PIPING CONFIGURATION
PRESSURE PREVENTER
REDUCING
VALVE
AIR GAP
LTODRAIN
SCALE: N.T.S.
PRESSURE
REDUCING VALVE
BACKFLOW
WATE R PREVENTER
METER
MAKE UP WATER
SYSTEM SUPPLY
SENSOR
(OPTIONAL)
BALL VALVE
(TYP ICAL)
SYSTEM
CIRCULATOR
P-RAD
EXPANSION
TANK
PRESSURE
GAUGE
DRAIN POINT
(TYPICAL)
BOILER
EXPANSION TANK TO BE SIZED BY
CONTRACTOR BASED ON FINAL
PIPING VOLUME. DESIGN BASED ON
AMTROL ST-6C
AIR
SEPARATOR
t
UNION
(TYPICAL)
j
Y-STRAINER
CH ECK
VALVE
EXPANSION TANK TO BE SIZED BY
CONTRACTOR BASED ON FINAL
PIPING VOLUME. DESIGN BASED ON
AMTROL AX-20V
AIR INLET
WITH SCREEN ----_'
SEALED
CAP
FLUE EXHAUST
SEAL
COMBUSTION AIR
+---- EXISTING
SIZE
1-1/2" 1-1/4"
TEMPERATURE /
PRESSURE
GAUGE
BOILER FLUE RE-USE OF STACK DETAIL
DRAIN
SCALE: N.T.S.
DIR #2000529680
BASEBOARD/ UNIT HEATER PIPING A/E FIRM: DESIGNED: SUB SHEET NO.
PRIME: SDF
ICDS, LLC ~-•·• GUILFORD, CT
COMBI BOILER (WB-2) PIPING CONFIGURATIONS
KFH M4 ••• 00187811 TECH. REVIEW: .. .. SUBCONTRACTOR:
SCALE: N.T.S. DSF
DATE:
06/07/2019
TITLE OF DRAWING DRAWING NO.
BOILER PIPING DETAILS 457
144216 LOCATION WITHIN PARK
BUILDINGS 22 & 28 PMIS/PKG NO.
NAME OF PARK BOST 232490
BOSTON NATIONAL HISTORICAL PARK SHEET
REGION COUNTY STATE
9 OF 16 NORTHEAST SUFFOLK MASSACHUSETTS
NEEDLE VALVE COCK
W/ PRESSURE GAUGE
(TYP.)
THERMOWELL AND THERMOMETER
(TYP.)
RETURN
1----------- SUPPLY
NOTES:
MANUAL AIR VENTS AT ALL HIGH
POINTS IN PIPING SYSTEM
MANUAL AIR VENTS AT
ALL COIL HIGH POINTS
PIPE SIZE "A"
1. LOCATE PIPE UNIONS AND ARRANGE PIPING TO
ALLOW COIL REMOVAL.
2. SEE MECHANICAL PLANS FOR PIPE SIZE "A".
3. LOCATE THERMOWELL ON LINES 2" AND SMALLER
IN PIPE ELBOW.
4. PROVIDE DRAIN VALVES WITH HOSE BIBS AT ALL LOW
POINTS IN PIPING SYSTEM.
5. CONTROL VALVES SHALL BE FLANGED BODY OR UNIONS
INSTALLED TO PERMIT REMOVAL OF CONTROL VALVES.
TO -
1\I R
F_OW J PIPE SIZE "A"
Gli~ w X6" MINIMUM
' DRAIN VALVE AT COIL
'\__ LOW POINT SAME AS COIL
OUTLET SIZE BUT NOT LESS
THAN 314"
...___ 3/4" DRAIN VALVE
WITH HOSE BIB
HYDRONIC COIL DETAIL
SCALE:NTS
MANUAL SHUTOFF
UNIT -......__u...r--O,-
GAS PIPING TO APPLIANCES
SCALE:NTS
COMBINATION BALANCING/
ISOLATION VALVE --------~ :
ISOLATION VALVE 7 ~
§i ~---------- FLEXIBLE CONNECTION (TYP.)
THERMOMETER ----------ti--t
FLANGED CONNECTION --....__
COMBINATION SUCTION
DIFFUSER STRAINER -------
AJUSTABLE SUPPORT ---
FOOT
FLOOR---
STRAINER SLOWDOWN __ _,.,..
~---------- CHECKVALVE
0---------- PRESSURE GAUGE (Pl)
__,---PUMP
~-- FACTORY SUPPLIED
STRUCTURAL STEEL
BASE
~-- HEIGHT SAVING
SPRING MOUNTS
'---- 6" THICK CONCRETE
HOUSEKEEPING PAD
BASE MOUNTED PUMP PIPING DETAIL
SCALE:NTS
UNION (TYP.)
CONTROL VALVE
REDUCER (TYP.)
ISOLATION VALVE (TYP.)
'-- CALIBRATED BALANCE VALVE
DRAIN PAN
X" =MIN.DROP ------1
X/2 + 1" = LEG -----I
(MIN. 5")
RETURN BEND
DRAIN CONNECTION (1-1/4)"
COUPLING MINIMUM
NIPPLE
CLEANOUT PLUG
TEE
UNION
-D-
DISCHARGE MUST BE
BELOW LEVEL OF
DRAIN PAN
X = NEGATIVE INTERNAL STATIC PRESSURE AT FAN INLET
NOTES:
1. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP
2. PITCH DRAIN FOR PROPER RUN-OFF
3. MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM
INITIAL DRAIN SEAL
4. SUPPORT LENGTHY DRAIN LINES TO PREVENT SAG AND
CONDENSATE OVERFLOW
DRAIN PAN WATER SEAL
PIPING FOR DRAW-THRU UNIT
SCALE:NTS
PROVIDE ISOLATION VAVLE -
ON BOTH SIDES OF PUMP
STRAINER--
BLOW DOWN VALVE WITH
3/4" HOSE CONNECTION --
FLEXIBLE CONNECTION (TYP.) ----,.
(SEE SPECIFICATIONS)
LUBRICATION POINTS ----,.
FLANGE CONNECTION (TYP.) ----'
NOTES:
~- UNION (TYP.)
__,.,--- PRESSURE GAUGE
,,,--- NEEDLE VALVE COCK (TYP.)
._ __ REDUCER (TYP.)
I STRAIGHT PATTERN
TRIPLE DUTY VALVE
BELL & GOSSETT
ISOLATION VALVE
1. PUMP SHALL BE INSTALLED SO THAT IT CAN
BE REMOVED WITHOUT THE DISMANTLING OR
REMOVAL OF ANY PIPING OR VALVES.
2. SUPPORT PUMP IN ACCORDANCE TO SPECIFICATIONS.
IN-LINE PUMP DETAIL
SCALE: NTS
NOM. SIZE IN.
PIPE FT.
TUBING FT.
SUPPORT FROM STRUCTURE ABOVE WITH AC-CLAMP
OR BEAM CLAMP. ADD SUPPLEMENTAL STEEL ------J=l
AS REQUIRED.
INSULATION
PIPING
INSULATED PIPE HANGER DETAIL
SCALE:NTS
,---- INSULATION (VAPOR
BARRIER TYPE IS
REQUIRED FOR LOW
TEMPERATURE PIPE)
~-- PROVIDE HIGH COMPRESSIVE
STRENGTH INSULATION
(9 PCF MIN. DENSITY)
UNDER INSULATION SHIELD
'--- INSULATION SHIELD
AT HANGER
WELD
ADJUSTABLE CLEVIS HANGER ADJUSTABLE CLEVIS HANGER
PROVIDE INSULATION SHIEL
AND INSERT FOR ALL PIPING
(8" MIN. LENGTH)
1" MAX. --------,
t
1/2" DIA.
HANGER RODS WITH
36" MAX. SPACING ON
EACH CHANNEL
BAND
='.!-------- 1 5/8" 12 GAGE
CHANNEL OR 2"x2"x1/4"
ANGLE
SIDE VIEW
TRAPEZE HANGER FOR UP
TO 1000 LB. (453 KG) UNIFORM LOAD
TYPICAL PIPE HANGERS
MAXIMUM PIPE/lUBING SUPPORT SPACING
THRU 3/4 1 11/4 1 1/2 2 2 1/2 3 4 5 6 8 10 12 14 16
7 7 7 9 10 11 12 14 16 17 19 22 23 25 27
5 FT 6 7 8 8 9 10 12 13 14 16 - - - -
18 20 24
28 30 32
NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.
PIPE SUPPORT DETAIL
SCALE:NTS
A/E FIRM: DESIGNED: SUB SHEET NO. TITLE OF DRAWING
PRIME: SDF MECHANICAL DETAILS ~ (.······ ... ICDS, LLC ~-•·• LOCATION WITHIN PARK GUILFORD, CT KFH M5 BUILDINGS 22 & 28 ••• 00187811 TECH. REVIEW: NAME OF PARK .. .. SUBCONTRACTOR: DSF BOSTON NATIONAL HISTORICAL PARK
DATE: REGION COUNTY STATE
06/07/2019 NORTHEAST SUFFOLK MASSACHUSETTS
DRAWING NO.
144216
PMIS/PKG NO.
BOST 232490
1 Q OF 16
---1\r-?
OUTDOOR AIR
INTAKE LOUVER
AO
P-B1
MER SUMP
Al Al Al
H-?1---------~---+----+------1 F----1~--00-----;.¥1---'l t----+--------+----.---------\ HW RETURN FROM AHU HW COILS
BT-2 ~---::;HOl-{l~N--lOt--~------------'\ HW SUPPLY TO AHU HW COILS
P-AHU-3
BOILER PLANT CONTROLLER POINT LIST
POINT TYPE POINT NUMBER CONTROL FUNCTION
DO 1 BOILER ENABLE
DO 2 PUMP P-AHU-3 ENABLE
DO 3 DOMESTIC HW TANK DISABLE (WHEN UNOCCUPIED)
DI 1 BOILER ALARM OUTPUT
DI 2 PUMP P-AHU-3 FAULT
AO 1 BOILER LWT SETPOINT
AO 2 PUMP P-AHU-3 SPEED
Al 1 BOILER SUPPLY WATER TEMP
Al 2 BOILER BUFFER TANK HW SUPPLY WATER TEMP
Al 3 BOILER RETURN WATER TEMP
Al 4 HOT WATER SYSTEM SUPPLY TEMP
Al 5 HOT WATER SYSTEM RETURN TEMP
Al 6 HOT WATER SYSTEM DIFFERENTIAL PRESSURE
DEVICE CODE DEVICE TYPE
R/BLR INTERPOSING RELAY TO BOILER TT
R/ECM INTERPOSING RELAY TO ECM INPUT
R INTERPOSING RELAY
BLR BOILER OUPUT DRY CONTACT
ECM ECM DRY CONTACT OUTPUT
BLR BOILER ANALOG INPUT
ECM ECM ANALOG INPUT
ITS IMMERSION TEMPERATURE SENSOR
ITS IMMERSION TEMPERATURE SENSOR
ITS IMMERSION TEMPERATURE SENSOR
ITS IMMERSION TEMPERATURE SENSOR
ITS IMMERSION TEMPERATURE SENSOR
DPT DIFFERENTIAL PRESSURE TRANSMITTER
WB-1 HOT WATER PLANT CONTROL DETAIL
SCALE: NTS
o:'. o:'. w w t-t- _J _J ii: ii:
llJ _J o:'. z n. ii:
CHWS
CHWR
_J
C.)
o:'.
w i D w _J _J
:i:
C.)
AHU
00-...J
~-------1I W <( t- - Z (.!)
HWR
HWS
ZONE1
SMOKE DETECTOR FAN
SHUTDOWN INTERLOCK
(TYP FOR2)
RETURN AIR
FROM ZONES
0 0 -...J
~-------1I W <C t- - Z C)
3 HWR
HWS
ZONE2
AHU-3 CONTROLLER POINT LIST
POINT TYPE POINT NUMBER CONTROL FUNCTION
DO 1 AHU FAN ENABLE
DI 1 AHU VFD ALARM
DI 2 AHU FAN STATUS
AO 1 AHU FAN SPEED
AO 2 ZONE 1 HOT WATER VALVE ACTUATOR
AO 3 ZONE 2 HOT WATER VALVE ACTUATOR
AO 4 CHILLED WATER VALVE ACTUATOR
AO 5 RETURN AIR DAMPER ACTUATOR
AO 6 OUTDOOR AIR DAMPER ACTUATOR
Al 1 AHU SUPPLY AIR TEMP
Al 2 AHU RETURN AIR TEMP
Al 3 AHU MIXED AIR TEMP
Al 4/5 OUTDOOR TEMP & REL HUMIDITY
Al 6/7 ZONE 1 TEMP & RH
Al 8/9 ZONE 2 TEMP & RH
A/E FIRM: DESIGNED: SUB SHEET NO.
PRIME: SDF ~(······· ... ICDS, LLC ~-•·• GUILFORD, CT KFH M6 ••• 00187811 TECH. REVIEW: .. .. SUBCONTRACTOR: DSF
DATE:
06/07/2019
DEVICE CODE DEVICE TYPE
R/VFD INTERPOSING RELAY TO VFD INPUT
VFD RELAY OUTPUT FROM VFD
CSR CURRENT SENSING RELAY
VFD VFD ANALOG INPUT
PEA PROPORTIONAL ELECTRIC ACTUATOR
PEA PROPORTIONAL ELECTRIC ACTUATOR
PEA PROPORTIONAL ELECTRIC ACTUATOR
PEA PROPORTIONAL ELECTRIC ACTUATOR
PEA PROPORTIONAL ELECTRIC ACTUATOR
ADS AVERAGING DUCT TEMP SENSOR
ADS AVERAGING DUCT TEMP SENSOR
ADS AVERAGING DUCT TEMP SENSOR
0TH OUTDOOR COMBINATION TEMP/RH SENSOR
THT COMBINATION TEMP/RH TRANSMITTER
THT COMBINATION TEMP/RH TRANSMITTER
TITLE OF DRAWING DRAWING NO.
CONTROL DIAGRAMS 457
144216 LOCATION WITHIN PARK
BUILDINGS 22 & 28 PMIS/PKG NO.
NAME OF PARK BOST 232490
REGION COUNTY STATE 11 OF 16 NORTHEAST SUFFOLK MASSACHUSETTS
OUTDOOR AIR
'" rl rl
I
OAD ·7 I
I
I I
.---DUCT SMOKE
DETECTOR (EXISTING)
>-------1~1---1---1
'· I "' I I I / .-- -- "' '
I I \ \
I I \ I
I I ·. ·- --· I
: : t ___ _ ' I I / DO ~, ~ I I ·1· ,1,,'
I ~ ~: ~ BAC }------0
I : i I 1
. 1 I ,....__MARVEL PREMIUM CONTROLLER CONTROLLER
L · I I I I WITH BACNET MSfTP COMMUNICATION
, - , - , - , - , ::_ , - , ~ PROTOCOL TO PROVIDE ALL AHU CONTROL
AHU-9 CONTROL POINTS LIST
POINT TYPE POINT NUMBER CONTROL FUNCTION DEVICE CODE
DO 1 AHU-9 SYSTEM ENABLE R/BAC
AO 1 HOT WATER REHEAT COIL MEA
Al 1 ENTRY SPACE TEMP RTS
Al 2 ENTRY SPACE RELATIVE HUMIDITY RHS
- -H 'Al''AI'
E C A
T 0 ' '\. 1 ,, '\. 2 ,, I I /
~~ N L
G
HWR ''
HWS
DEVICE TYPE
RELAY TO BACNET CONTROLLER INPUT
MODULATING ELECTRIC ACTUATOR
ROOM TEMP SENSOR
ROOM HUMIDITY TRANSMITTER
AHU-9 CONTROL SCHEMATIC (OPTION A)
SCALE:NTS
I I
A/E FIRM: DESIGNED: SUB SHEET NQ_ TITLE OF DRAWING DRAWING NO_
<c. o~}?.Q~~~c~ PRIME: SDF CONTROL DIAGRAMS 457 ~-P-~-~ ICDS, LLC ~-•·• 144216 LOCATION WITHIN PARK o.,: --'-' GUILFORD, CT {Ii i* KFH M7 BUILDINGS 22 & 28 PMIS/PKG NO-
,~~8780 ---~ TECH_ REVIEW: BOST 232490 NAME OF PARK ---~--- SUBCONTRACTOR:
\ ~---------- DSF BOSTON NATIONAL HISTORICAL PARK SHEET
- DATE: REGION COUNTY STATE C,
12 OF 16 / '-7"·.r---- 06/07/2019 NORTHEAST SUFFOLK MASSACHUSETTS
480V BOSTON EDISON -----j,----7
TRANSFORMER T
3 SETS OF: -------;::Q'._,
[4 #300 MCM, 1 #4 G IN 3"C]
CT CABINET
DIST. PANEL "DP-2"
120 / 208V, 400A
I I I I I I M WP ~ ,oo,_ I, 1 '" < 400A, 100A, 100A, 2 25A, 225A, 225A, 3 SETS OF:-------
[4 #300 MCM, 1 #4 G IN 3"~1>
WP
MAIN DISTRIBUTION
PANEL "MDP"
800A, 3P
KRP-C FUSES
200A, 3P ;:j LPS-RK
FUSES
200A, 3P ;:j LPS-RK
FUSES
200A, 3P (
LPS-RK §
FUSES
200A, 3P
LPS-RK
FUSES
§ 3P
FEEDER
4 #500 MCM, 1 #3 G IN 3 ½"C ---< P ct>-- 3 #500 MCM, 1 #3 GIN 3"C
~ 3P
PANEL
"2A,2B"
~ 3P 3P ~ 3P ~ 3 p
KITCHEN
PANEL
ELEVATOR PANEL
npMn
REPLACE EXISTING AHU-9, 30 C.B.
WITH NEW GE 60A, 30 C.B.
3 #4, #10 GIN 1 ¼" C
3P
PANEL
"PP1"
60N3P ,.., 4 #3/0, 1 #6 GIN 2 ½"C L -------<:J> ____ ----<p
, _,,.-- 480V, 120/208 V
~------<TV 300kVA TRANSFORMER, NEMA 3R
- - -----, DISC. SW.
3P
PANEL
"LP1A"
SPARE
AUTOMATIC
TRANSFER
--,- SWITCH
~ _ RAINPROOF ENCLOSURE
I 60A I 208V, 30 I
PANELBOARD "EH1"
480V, 30, 400A, 42 CKT.
:) 200A 0 ) 100A
&0.
150kW
GENERATOR
/1 - I
4 #500 MCM, 1 ~--<p
#3 GIN 3½"C
) 70A 3P 3P 3P 3P 3P 3P 3P 3P
SPACE SPACE SPACE SPACE SPACE
120 TON
CHILLER
SWITCHBOARD "SWBD"
120 / 208V, 1200A WITH INCOMING
SEv,.-,.
400A, 3P
600A, 3P
3 SETS OF:
[4 #500 MCM, 1 #3 G IN 3 ½"CJ
'1 v1200A, 30 FUSED DISC. SWITCH.
1200A TYPE KRP-C FUSES
~ NEMA 3R RAINPROOF ENCLOSURE
400A, 3P
3 SETS OF:
14 #500 MCM. 1 #3 G IN 3 ½"Cl
100A, ~ 3P
50A, 3P ef 30A, § 3P
1 200A, § 3P
SPARE
1 200A, § 3P
SPARE
3 #4, #8 GIN 1 ¼"C----< c, 4 #500 MCM, #3 GIN 3½"C ct>-- 4 #8, #10 GIN 1"C
--4 #6, #10 GIN 1 ¼"C
4 #3/0, #6 G IN 2"C - ---::t:>
4 #2, #8 GIN 1
GEA SERIES
PANELBOARD
IILAPII
BUILDING
SCALE
BUILDING
--4 #2, #8 GIN 1 ½"C
TENNIS COURT
LIGHTING ½"C
TO
CAPSTAN
MOTOR
/GUTTER
TO DRY
DOCK
TO LIGHTING
CASSIN
MOTOR
PUMP
100A, 30
FUSED
DISC.SW.
200A, 30
FUSED
DISC.SW.
, • • 120/208 - 120/240
T--75kVA
TRANSFORMER
FEED EXISTING I BUILDING 28 - - - - - - -~ - -7
PANELBOARDS IN GE SERIES A 7 I
BUILDING 28 : PANELBOARD :
I IIL1AII I
REPLACE EXISTING 25A, 30 C.B. 120 / 208V, 30, 4W
120 / 208V, 30, 4W
400AMLO
42 CKT.
FEED THROUGH
LUGS
I
PANELBOARD
"LAL"
120 / 208V, 30, 4W
400A MLO
30 CKT. ~----3 SETS OF:
/ [4 #350 MCM, #1 G IN 3"C]
v [4#2, #8 GIN 1 ½"C
ATS
TO BUILDING 22 t - v _'."'o--0
FOR AHU-4 AND REPLACE WITH (2) 1 400A MLO 1
GE 20A,10 BREAKERS FOR BOILERS r-----__' 42 CKT. I J,r"REPLACE EX.40A, 30 C.B. FORAHU-4 WB-1 & WB-2. __ r l AND REPLACE WITH GE 90A, 30 C.B.
55kW
GENERATOR
,{ 2 #12, #12 GIN¾"~ ~ ~N1P 90~)1/ I FOR NEW AHU-3.
0- ~--...._----------------------, rf,--- 3 #12, #12 p IN ¾"C ~N2P 20N3P _ ..... !i---PROVIDE NEW GE 20A, 30 C.B.
n_t;r---------:-, ---------r--- 0- ~n~i---;.,-.......:_.:...:..., rf,--- 2 12, #12 GIN ¾"C ~N1P r,_&'-----+-------+-o 0-
<D--3 #2, #8 GIN 1 ½"C
L_~~~=-J
OPTION A
} 30A J }M
JISC.SW WB-1
208V
, 10,P.f,!3P I r" o-
14 #2, #8 G IN 1 ½"C-<---,-P _____ _
<D-- 3 #12, #12G IN ¾"C
WIREWAY
<l>----<l>- 3 #12, #12G IN ¾"C 100A u
DISC. SW.
208V, 30
AHU-3
VFD
I ~ PROVIDED BY MECHANICAL
V CONTRACTOR, INSTALLED BY
ELECTRICAL CONTRACTOR
I
WB-2
I
I I
I
PANELBOARD
P-RAD , "L2A"
30N10AFU
208V, 30
DISC. SW
30N10AFU
208V, 30
DISC.SW
.. I 120 / 208V
1 100A MLO
, 30,4W
L ___ ~2-~ ________ J 2HP
P-AHU-3
2 HP
P-B1
••• 00187811
120/208V, 3 PHASE, 4 WIRE
PANEL "L 1A" SCHEDULE
3 PHASE LINE BUS: 400 AMP
NEUTRAL BUS: 400A
BRANCH POLES: 36 POLE
(GE SERIES A)
AIC: 22,000
DESCRIPTION BKR CKT PH-A PH-B PH-C CKT BKR DESCRIPTION
PANEL 2nd FLOOR 100A/ 1 I 5040 2 l'\.90A AHU 3
L2A? / 3 I 5040 4 '\ SEE NOTE 4 BELOW
V 5 I 5040 6 ' SPRINKLER PUMP 20/Y 7 I 8 l'\20A DUCT FAN #2
./ 9 I 10 '\ DUCT FAN #1 203/ 11 I 12 ' / 13 I 14 l'\.20A HEATER PUMP
I/ 15 I 16 '\, BOILER WB-2 20A 17 .r-SEE NOTE 3BELOW 1125 I 18 " PUMP P-RAD 2oy 19 562 I 20 15A BOILER
/ 21 562 I 22 15A CABINET HEATER
MECH. ROOM RECEPTACLE 20A 23 I 24 20A CONTROLS FOR HEAT
BOILER WB-1 20A 25 I 1801 SEE NOTES 1 i 2BELOW- 26 l'\.20A PUMPS
COURTYARD OUTLETS 20A 27 I 1801
28 '\, (SEE NOTES BELOW)
COURTYARD OUTLETS 20A 29 I 1801 , 30 " COURTYARD OUTLETS 20A 31 I 32 20A COURTYARD OUTLETS
208V MOTOR 20,v 33 I 34 20A COURTYARD OUTLETS
2nd FLOOR DISPLAY ../ 35 SEE ~OTE 1 BELOW 36 20A OUTLET/BACK WALL OUTSIDE THIS RM
TOTAL DESIGN VA TOTAL DESIGN AMPS
NOTES:
1. RELOCATE EXISTING 20A, 10 CB FROM CKT. 26 TO CKT 36. EXTEND CONDUCTORS AS REQ'D.
2. PROVIDE NEW 20A, 30 C.B. FOR NEW PUMP CIRCUIT.
3. REPLACE EXISTING 25A, 30 C.B. WITH (1) NEW 20A, 10, 1P, C.B. & (1) NEW20A, 10, 2P, C.B.
4. REPLACE EXISTING 40A, 30 C.B. WITH NEW 90A, 30 C.B.
1201208V, 3 PHASE, 4 WIRE
PANEL "PP1" SCHEDULE 3 PHASE LINE BUS: 225 AMP
NEUTRAL BUS: 225A
BRANCH POLES: 24 POLE
(ATLANTIC SWBD & ENG. CORP.)
AIC: 10,000
DESCRIPTION BKR CKT PH-A PH-B PH-C CKT BKR DESCRIPTION
CONTROL CIRCUIT 20A 1 I 2 20A OUTLETS
OUTLETS 20A 3 I 4 20A STORAGE LIGHTS
MECANICAL CONTROL PANEL 20A 5 250 I 180 6 20A RECEPTACLE (NOTE 2)
HUMIDIFIER 60A/ 7 I 8 '-.20A FRONT ENTRANCE HEATER
/ 9 I 10 '\.
I/ 11 I 12 '\.
UH-8 40A/ 13 I 14 '-...A HUMIDIFIER
/ 15 I 16 '\.
I/ 17 I 18 '\
NEW AIR HANDLING UNIT 60A/ 19 5154 I 20 '-l_OOA AC- 2nd FLOOR
AHU-9 (OPTION A) / 21 5154 I 22 '\.
SEE NOTE 1 BELOW I/ 23 5764 I 24 '\.
TOTAL DESIGN VA TOTAL DESIGN AMPS
NOTES:
1. REPLACE EXISTING SIEMENS 40A, 30 C.B. WITH NEW 60A, 30 C.B.
2. PROVIDE NEW 20A, 10 C.B.
A/E FIRM: DESIGNED: SUB SHEET NO. TITLE OF DRAWING DRAWING NO.
PRIME: SDF ELECTRICAL ONE-LINE DIAGRAM 457
ICDS, LLC 144216 ~-•·• GUILFORD, CT LOCATION WITHIN PARK
KFH
EO BUILDINGS 22 & 28 PMIS/PKG NO.
TECH. REVIEW: NAME OF PARK BOST 232490
SUBCONTRACTOR: DSF BOSTON NATIONAL HISTORICAL PARK SHEET
DATE: REGION COUNTY STATE 13 OF 16 06/07/2019 NORTHEAST SUFFOLK MASSACHUSETTS
J
<I
Ir
LOBBY
B
L ___________ 7
I I I I I I
STORAGE ROOM
l}
I c:::::::::-
STORAGE
ROOM
CONNECTOR
AUDITORIUM
STAIRS
PROJECTION
BOOTH
I\.._ ______ ,_ _ ________ _ .....;;;O~P;;;;_T;--;;!._;;;-O-;;;N;;;;A=+I,--, ,--~~11----'
EP PANE
"EH1" (Vl,i='T-1.-. MECHANICAL coN-ROL PANEL
2#12 & #12G. IN¾" C. TO SPARE
\ CIRCUIT PP1-5.
~---l.......L-'---1....J.......L.....L....J.....J.......L>.. ___ _____., I
'7, ~IL-------1--' ------~
: STORAGE' /
ROOM I.___
CONTRACTOR SHALL REMOVE EXISTING DUCT DETECTOR TO
ACCOMODATE NEW MECHANICAL EQUIPMENT AND DUCTWORK
INSTALLATION. REINSTALL DUCT DETECTOR IN SUPPLY SIDE
AHEAD OF REHEAT COIL. COORDINATE WITH MECHANICAL DWGS.
STORAGE ROOM
3#4 & #10G. IN 1 ¼" C. TO EXISTING---\
AHU-9 CKT.19,21,23 IN PANEL PP-1.
PROVIDE NEW 60A, 30 C.B. AS REQ'D.
... ~ A II . -
MCA 48A ,=======-l
STREET
---PANEL "LAL" (VIF)
I LIGHTS
I (VIF) PANEL "LAP" (VIF)
ATS (VIF)
NOTE:
I - 2#12 & #12G. IN¾" C. ALL EXISTING LIGHTING AND RECEPTACLES SHALL REMAIN. I
TO CKT. 6 IN PANEL PP-1. CONTRACTOR SHALL REMOVE AND REINSTALL EXISTING
I PROVIDE NEW 20A, 10 C.B. (2) LAMP 4' LIGHTING FIXTURES (TYP. FOR 3) AS REQUIRED TO I L ACCOMODATE NEW MECHANICAL EQUIPMENT AND DUCTWORK I _______________________ I_Ns_~~~I_o_N._______ __
'1' BUILDING 22 1st FLOOR ELECTRICAL PLAN ~ 4 0 4 8 -- ----
SCALE IN FEET
N N C!)
_J
KEY PLAN
C0 N C!)
_J
••• 00187811
I I
WOMEN MEN
f ATC~ L __ J
FIRST FLOOR SUBSTATION
MECHANICAL ROOM
BELOW AHU-2
H'
L_ ____ ___JI ___ _J_ ______ ----1... ___ ~-----r--- - ----@
A/E FIRM: DESIGNED: SUB SHEET NO. TITLE OF DRAWING
PRIME: SDF AHU-9 REPLACEMENT
ELECTRICAL PART PLAN ICDS, LLC ~-•·• LOCATION WITHIN PARK GUILFORD, CT KFH
El BUILDINGS 22 & 28
TECH. REVIEW: NAME OF PARK
SUBCONTRACTOR: DSF BOSTON NATIONAL HISTORICAL PARK
DATE: REGION COUNTY STATE
06/07/2019 NORTHEAST SUFFOLK MASSACHUSETTS
DRAWING NO.
144216
PMIS/PKG NO.
BOST 232490
'" N t.l=
IT
I
ELEVATOR
MACHINE
R 00 M .---,_~ ---1.Jl
---- H---------------------------------tt -
MATCH LINE
3#2 & #BG. IN 1 ½" C. ----------
TO EXISTING AHU-3 CKT. IN PANELL 1A.
PROVID~ 90A, 30 C.B. AS RE~ 1iED
MATCHLINE - - - -
t--- - ---@
PROVIDE 100A, 30 DISC. SW. FOR NEW AHU-3.---.
COORDINATE LOCATION IN FIELD. .------++- MECHANICAL CONTROL PANELS
L1A
VFD PROVIDED BY MECHANICAL CONTRACTOR. -
INSTALLED BY ELECTRICAL CONTRACTOR.
COORDINATE LOCATION IN FIELD.
I
[II::=- tT-------i:;ti_::::C~I• tr==::.x .. =.=.=..:r-1 3#12 & #12G. IN ¾"C. ------t--1. .....,.__.-
WORK PROVIDE 30N10AF, 30~ \ , >--3#2 & #BG. IN 1 ½"C.
ROOM DISC. SW. (TYP. FOR 2) \. P-AHU-3
-- SPRINKLE=> __.-- 3#12 & #12G. IN ¾"C.---....,__ .~v~-==si□~
FROM WIREWAY TO """
VALVE \ PANELL 1A-26,2B,30. J □ PB-1
ROOM 3#12G. IN¾"C.--"""1 1111:.--n
111111 A ~-
2#12 & #12G. IN¾" C. TO CKT. 17 & 1'.:9------~1J1A~-1!19~5--~
IN PANELL 1A. REMOVE EXISTING ; t:S-1! 15A, j5A, 120V
AHU-4, 25A, 30 C.B. AND PROVIDE 120V
(2) NEW 20A, 10 C.B. AS REQUIRED. -$- f+- • ' ..__ .._,,,_ • _) rt_•,• "□-~AD - , ~, 3#12 & #12G. IN ¾"C.
TO PANELL 1A-19,21.
EPO SWITCHES WB-1 & WB-2, STACKED
\_ FOR EMERGENCY SHUTDOWN OF
\, BOILERS JUST INSIDE DOOR I
AHU-3
20BV, 30, 60H2
42 FLA
[Il::::=
MECHANICAL
L1A-23 ROOM
1 EX.
TO EXISTING CONTROLS CIRCUIT.
t--- - ----@
CONTRACTOR SHALL REMOVE EXISTING DUCT DETECTOR TO
ACCOMODATE NEW MECHANICAL EQUIPMENT AND DUCTWORK
INSTALLATION. REINSTALL DUCT DETECTOR IN SUPPLY SIDE
COORDINATE WITH MECHANICAL DWGS (TYP. FOR 2).
NOTE:
ALL EXISTING LIGHTING AND RECEPTACLES SHALL
REMAIN. CONTRACTOR SHALL REMOVE AND REINSTALL
EXISTING (2) LAMP 4' LIGHTING FIXTURES (TYP. FOR 4)
AS REQUIRED TO ACCOMODATE NEW MECHANICAL l'-=======l
1 1 1 1 EQUIPMENT AND DUCTWORK INSTALLATION.
1-------P~~~:;;;;:---Jjt----c!:I ==~1,----__ "'-I __ _Jl,------H~--~==:::::::'..f-- _ ---@
-EXISTING
RECEPTACLE (VIF)
J M
0 ~UILDING 28 1st FLOOR ELECTRICAL PLAN 4 0 4 8 -- ----
SCALE IN FEET
A/E FIRM: DESIGNED: SUB SHEET NO. TITLE OF DRAWING DRAWING NO.
BLDG. 28 AHU REPLACEMENT PRIME: SDF 457
ELECTRICAL PART PLAN N ~ (.······ ... ICDS, LLC ~-•·• 144216 N
LOCATION WITHIN PARK (!) "' GUILFORD, CT Cl "' KFH E2 ..J (!) BUILDINGS 22 & 28 PMIS/PKG NO • Cl] Cl
..J ••• 00187811 TECH. REVIEW: BOST 232490 ID .. NAME OF PARK .. SUBCONTRACTOR: DSF BOSTON NATIONAL HISTORICAL PARK SHEET DATE: KEY PLAN REGION COUNTY STATE 15 OF 16 06/07/2019 NORTHEAST SUFFOLK MASSACHUSETTS
"' rl rl
OMITTED FROM
PROJECT SCOPE
CONNECTOR
SUB-STA Tl Cl _J
"' v" .,, KEY PLAN
CX)
<N Cl _J
A/E FIRM:
<c. o~}?.Q~~~c~ PRIME: ~-P-~-~ ICDS, LLC o.,: --'-' GUILFORD, CT {Ii i*
,~~8780 ---~ ---~--- SUBCONTRACTOR:
C, _/ '-7"·.r----
DESIGNED: SUB SHEET NO_ TITLE OF DRAWING DRAWING NO_
CONNECTOR AHU REPLACEMENT 457 SDF ELECTRICAL PART PLAN ~-•·• 144216 LOCATION WITHIN PARK
KFH E3 BUILDINGS 22 & 28 PMIS/PKG NO-
TECH_ REVIEW: BOST 232490 NAME OF PARK
DSF BOSTON NATIONAL HISTORICAL PARK SHEET
DATE: REGION COUNTY STATE 16 OF 16 06/07/2019 NORTHEAST SUFFOLK MASSACHUSETTS
| 060719-USS-Const-CS-100CD |
| 060719-USS-Const-DM1-100CD |
| 060719-USS-Const-DM2-100CD |
| 060719-USS-Const-DM3-100CD |
| 060719-USS-Const-M0-100CD |
| 060719-USS-Const-M1-100CD |
| 060719-USS-Const-M2-100CD |
| 060719-USS-Const-M3-100CD |
| 060719-USS-Const-M4-100CD |
| 060719-USS-Const-M5-100CD |
| 060719-USS-Const-M6-100CD |
| 060719-USS-Const-M7-100CD |
| 060719-USS-Const-E0-100CD |
| 060719-USS-Const-E1-100CD |
| 060719-USS-Const-E2-100CD |
| 060719-USS-Const-E3-100CD |
File details come from the government source that posted it. Updated .