This technical specification document details a contract for the U.S. Fish and Wildlife Service at the Green Lake National Fish Hatchery to replace a 2,000-gallon fuel storage tank with a 1,000-gallon above ground diesel fuel storage tank. The project involves removing the existing tank, disposing of it according to environmental standards, and installing a new tank on the existing concrete pad. The new tank must meet safety requirements for primary and secondary containment, leak monitoring, spill containment, and overfill protection.
The contract is anticipated to be awarded in July 2025 as a firm-fixed price contract, with work to be completed within 30 calendar days of the Notice to Proceed. The contractor will be responsible for providing all labor, equipment, materials, and supplies necessary for the tank replacement. Required submittals include manufacturer's technical data, specifications, installation instructions, and warranty information. The project will be coordinated with the hatchery's operations, and the point of contact is Brian Waz, Project Engineer/Contracting Officer's Representative, who can be reached at brian_waz@fws.gov or (413)-253-8605.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140FC226Q0001_Amd_0003.pdf | ||
| 140FC226Q0001_Q_A_0003.docx | DOCX document | |
| Sol_140FC226Q0001_Amd_0002.pdf | ||
| Sol_140FC226Q0001_Amd_0001.pdf | ||
| Sol_140FC226Q0001.pdf | ||
| B03_WD.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U.S. Fish and Wildlife Service – Green Lake N.F.H. 1 of 2 Technical Specifications – Replacement of 2,000-gallon Fuel Storage Tank
TECHNICAL SPECIFICATIONS
Replacement of 2,000-Gallon Fuel Storage Tank
PART 1 - PROJECT OVERVIEW
A. NOTICES
1. Project Information
Project Title: Replace 2,000-Gallon Fuel Storage Tank
Locations: U.S. Fish & Wildlife Service Green Lake National Fish Hatchery
One Hatchery Way Ellsworth, ME 04605
Contracting Officer (CO): TBD
Project Engineer / Contracting Brian Waz, brian_waz@fws.gov, (413)-253-8605
Officer’s Representative (COR):
FWS Hatchery P.O.C.: Craig Knights, craig_knights@fws.gov, (207)-317-2123
B. PROJECT DETAILS
1. Contract Work:
This Contract is to remove and dispose of the existing 2,000-gallon above ground diesel fuel storage tank with a 1,000-Gallon above ground diesel Fuel Storage Tank, reconnect all existing supply lines, and install existing equipment. The tank will be replacing an existing failing tank and will be placed on an existing concrete slab on grade outside to supply diesel fuel for an emergency generator.
The tank shall comply with all industry standard best practices, regulations, and materials.
2. Hatchery Operations:
Hatchery operations will continue during the performance of this contract. The Contractor shall coordinate with the Hatchery P.O.C. above and mutually decide on the best time to perform the work.
3. Anticipated Award Period / Contract Type:
The Government anticipates a firm-fixed priced award of this contract July 2025.
4. Completion Date:
The work shall be completed no later than 30 calendar days from the Notice to Proceed issued by the Contracting Officer.
U.S. Fish and Wildlife Service – Green Lake N.F.H. 2 of 2 Technical Specifications – Replacement of 2,000-gallon Fuel Storage Tank
PART 2 – SCOPE OF SERVICES
A.
1. SCOPE
Replacement of 2,000-gallon Fuel Storage Tank (Base Bid Item):
The Contractor shall provide including but not limited to:
Supply all labor, equipment, materials, and supplies necessary to remove the existing 2,000 – Gallon fuel tank and replace with a new 1,000-gallon fuel tank (Refer to App. 1 for photos of existing system).
Disconnect existing piping from exiting 2,000-gallon fuel tank.
Remove existing 2,000-gallon tank from existing concrete pad.
Properly treat and dispose of exiting 2,000-gallon fuel storage tank as per environmental standards and regulations.
Set new 1,000-gallon fuel storage tank on existing concrete pad.
Reconnect existing supply and return lines.
Fit new tank with government supplied equipment (i.e. pump).
Tank Specifications:
1,000 – Gallon Above Ground Diesel Fuel Storage Tank (No pump needed) Tank must meet all safety requirements for primary and secondary containment, leak monitoring, spill containment, and overfill protection.
2. Project Submittals:
The following information is required from the Contractor, but not limited to:
Manufacturer’s Technical Data and Specifications Manufacturer’s Installation Instructions Warranty information
Submittals shall be emailed to the following:
Contracting Officer (CO): TBD
Project Engineer / Contracting Officer’s Representative (COR): Brian Waz, brian_waz@fws.gov, (413)-253-8605
APPENDIX 1:
Photographs
2,000 –gallon Fuel Storage Tank and Components
Photo #1: View of 2,000-gallon fuel storage tank.
Photo #2: End view of 2,000-gallon fuel storage tank.
Photo #3: End view of 2,000-gallon fuel storage tank with supply and return lines.
Photo #4: View of tank lines.
Photo #5: View of tank lines.
| Technical Spec. - GLNFH - Replacement of 2,000-gallon Fuel Storage Tank.pdf |
| APPENDIX 1 |
File details come from the government source that posted it. Updated .